1.
J Proteome Res ; 22(6): 1734-1746, 2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37010854

RESUMEN

In this study, we present high-throughput (HT) venomics, a novel analytical strategy capable of performing a full proteomic analysis of a snake venom within 3 days. This methodology comprises a combination of RP-HPLC-nanofractionation analytics, mass spectrometry analysis, automated in-solution tryptic digestion, and high-throughput proteomics. In-house written scripts were developed to process all the obtained proteomics data by first compiling all Mascot search results for a single venom into a single Excel sheet. Then, a second script plots each of the identified toxins in so-called Protein Score Chromatograms (PSCs). For this, for each toxin, identified protein scores are plotted on the y-axis versus retention times of adjacent series of wells in which a toxin was fractionated on the x-axis. These PSCs allow correlation with parallel acquired intact toxin MS data. This same script integrates the PSC peaks from these chromatograms for semiquantitation purposes. This new HT venomics strategy was performed on venoms from diverse medically important biting species; Calloselasma rhodostoma, Echis ocellatus, Naja pallida, Bothrops asper, Bungarus multicinctus, Crotalus atrox, Daboia russelii, Naja naja, Naja nigricollis, Naja mossambica, and Ophiophagus hannah. Our data suggest that high-throughput venomics represents a valuable new analytical tool for increasing the throughput by which we can define venom variation and should greatly aid in the future development of new snakebite treatments by defining toxin composition.


Asunto(s)
Mordeduras de Serpientes , Viperidae , Animales , Proteómica/métodos , Venenos de Serpiente/química , Bungarus/metabolismo , Viperidae/metabolismo , Venenos Elapídicos/química
2.
Anal Chem ; 95(51): 18767-18775, 2023 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-38092659

RESUMEN

Analytical methods for the assessment of drug-delivery systems (DDSs) are commonly suitable for characterizing individual DDS properties, but do not allow determination of several properties simultaneously. A comprehensive online two-dimensional liquid chromatography (LC × LC) system was developed that is aimed to be capable of characterizing both nanoparticle size and encapsulated cargo over the particle size distribution of a DDS by using one integrated method. Polymeric nanoparticles (NPs) with encapsulated hydrophobic dyes were used as model DDSs. Hydrodynamic chromatography (HDC) was used in the first dimension to separate the intact NPs and to determine the particle size distribution. Fractions from the first dimension were taken comprehensively and disassembled online by the addition of an organic solvent, thereby releasing the encapsulated cargo. Reversed-phase liquid chromatography (RPLC) was used as a second dimension to separate the released dyes. Conditions were optimized to ensure the complete disassembly of the NPs and the dissolution of the dyes during the solvent modulation step. Subsequently, stationary-phase-assisted modulation (SPAM) was applied for trapping and preconcentration of the analytes, thereby minimizing the risk of analyte precipitation or breakthrough. The developed HDC × RPLC method allows for the characterization of encapsulated cargo as a function of intact nanoparticle size and shows potential for the analysis of API stability.


Asunto(s)
Cromatografía de Fase Inversa , Nanopartículas , Cromatografía de Fase Inversa/métodos , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Colorantes , Glicoles , Hidrodinámica , Solventes/química , Nanopartículas/química
3.
Anal Chem ; 95(19): 7487-7494, 2023 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-37146101

RESUMEN

We report an online analytical platform based on the coupling of asymmetrical flow field-flow fractionation (AF4) and native mass spectrometry (nMS) in parallel with UV-absorbance, multi-angle light scattering (MALS), and differential-refractive-index (UV-MALS-dRI) detectors to elucidate labile higher-order structures (HOS) of protein biotherapeutics. The technical aspects of coupling AF4 with nMS and the UV-MALS-dRI multi-detection system are discussed. The "slot-outlet" technique was used to reduce sample dilution and split the AF4 effluent between the MS and UV-MALS-dRI detectors. The stability, HOS, and dissociation pathways of the tetrameric biotherapeutic enzyme (anticancer agent) l-asparaginase (ASNase) were studied. ASNase is a 140 kDa homo-tetramer, but the presence of intact octamers and degradation products with lower molecular weights was indicated by AF4-MALS/nMS. Exposing ASNase to 10 mM NaOH disturbed the equilibrium between the different non-covalent species and led to HOS dissociation. Correlation of the information obtained by AF4-MALS (liquid phase) and AF4-nMS (gas phase) revealed the formation of monomeric, tetrameric, and pentameric species. High-resolution MS revealed deamidation of the main intact tetramer upon exposure of ASNase to high pH (NaOH and ammonium bicarbonate). The particular information retrieved from ASNase with the developed platform in a single run demonstrates that the newly developed platform can be highly useful for aggregation and stability studies of protein biopharmaceuticals.


Asunto(s)
Fraccionamiento de Campo-Flujo , Proteínas , Hidróxido de Sodio , Espectrometría de Masas , Refractometría , Asparaginasa , Fraccionamiento de Campo-Flujo/métodos
4.
Anal Chem ; 94(21): 7647-7654, 2022 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-35587271

RESUMEN

In many areas, studying photostability or the mechanism of photodegradation is of high importance. Conventional methods to do so can be rather time-consuming, laborious, and prone to experimental errors. In this paper we evaluate an integrated and fully automated system for the study of light-induced degradation, comprising a liquid handler, an irradiation source and exposure cell with dedicated optics and spectrograph, and a liquid chromatography (LC) system. A liquid core waveguide (LCW) was used as an exposure cell, allowing efficient illumination of the sample over a 12 cm path length. This cell was coupled to a spectrograph, allowing in situ absorbance monitoring of the exposed sample during irradiation. The LCW is gas-permeable, permitting diffusion of air into the cell during light exposure. This unit was coupled online to LC with diode array detection for immediate and automated analysis of the composition of the light-exposed samples. The analytical performance of the new system was established by assessing linearity, limit of detection, and repeatability of the in-cell detection, sample recovery and carryover, and overall repeatability of light-induced degradation monitoring, using riboflavin as the test compound. The applicability of the system was demonstrated by recording a photodegradation time profile of riboflavin.


Asunto(s)
Riboflavina , Cromatografía Liquida , Difusión , Análisis Espectral
5.
Anal Chem ; 94(46): 16060-16068, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-36318471

RESUMEN

The majority of liquid chromatography (LC) methods are still developed in a conventional manner, that is, by analysts who rely on their knowledge and experience to make method development decisions. In this work, a novel, open-source algorithm was developed for automated and interpretive method development of LC(-mass spectrometry) separations ("AutoLC"). A closed-loop workflow was constructed that interacted directly with the LC system and ran unsupervised in an automated fashion. To achieve this, several challenges related to peak tracking, retention modeling, the automated design of candidate gradient profiles, and the simulation of chromatograms were investigated. The algorithm was tested using two newly designed method development strategies. The first utilized retention modeling, whereas the second used a Bayesian-optimization machine learning approach. In both cases, the algorithm could arrive within 4-10 iterations (i.e., sets of method parameters) at an optimum of the objective function, which included resolution and analysis time as measures of performance. Retention modeling was found to be more efficient while depending on peak tracking, whereas Bayesian optimization was more flexible but limited in scalability. We have deliberately designed the algorithm to be modular to facilitate compatibility with previous and future work (e.g., previously published data handling algorithms).


Asunto(s)
Algoritmos , Quimiometría , Teorema de Bayes , Cromatografía Liquida/métodos , Espectrometría de Masas/métodos
6.
Analyst ; 146(10): 3197-3207, 2021 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-33999083

RESUMEN

Many organic compounds undergo changes under the influence of light. This might be beneficial in, for example, water purification, but undesirable when cultural-heritage objects fade or when food ingredients (e.g., vitamins) degrade. It is often challenging to establish a strong link between photodegradation products and their parent molecules due to the complexity of the sample. To allow effective study of light-induced degradation (LID), a low-volume exposure cell was created in which solutes are efficiently illuminated (especially at low concentrations) while simultaneously analysed by absorbance spectroscopy. The new LID cell encompasses a gas-permeable liquid-core waveguide (LCW) connected to a spectrograph allowing collection of spectral data in real-time. The aim of the current study was to evaluate the overall performance of the LID cell by assessing its transmission characteristics, the absolute photon flux achieved in the LCW, and its capacity to study solute degradation in presence of oxygen. The potential of the LID set-up for light-exposure studies was successfully demonstrated by monitoring the degradation of the dyes eosin Y and crystal violet.

7.
Anal Bioanal Chem ; 413(17): 4379-4386, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34050389

RESUMEN

Trifluoroacetic acid (TFA) is commonly used as mobile phase additive to improve retention and peak shape characteristics in hydrophilic interaction liquid chromatography (HILIC) of intact proteins. However, when using electrospray ionization-mass spectrometry (ESI-MS) detection, TFA may cause ionization suppression and adduct formation, leading to reduced analyte sensitivity. To address this, we describe a membrane-based microfluidic chip with multiple parallel channels for the selective post-column removal of TFA anions from HILIC. An anion-exchange membrane was used to physically separate the column effluent from a stripper flow solution comprising acetonitrile, formic acid, and propionic acid. The exchange of ions allowed the post-column removal of TFA used during HILIC separation of model proteins. The multichannel design of the device allows the use of flow rates of 0.2 mL/min without the need for a flow splitter, using mobile phases containing 0.1% TFA (13 mM). Separation selectivity and efficiency were maintained (with minor band broadening effects) while increasing the signal intensity and peak areas by improving ionization and reducing TFA adduct formation.


Asunto(s)
Dispositivos Laboratorio en un Chip , Proteínas/análisis , Ácido Trifluoroacético/aislamiento & purificación , Animales , Bovinos , Pollos , Cromatografía Liquida , Diseño de Equipo , Caballos , Interacciones Hidrofóbicas e Hidrofílicas , Espectrometría de Masa por Ionización de Electrospray
8.
Adv Exp Med Biol ; 1336: 51-86, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34628627

RESUMEN

This chapter aims to explore various parameters involved in achieving high-end capillary electrophoresis hyphenated to mass spectrometry (CE-MS) analysis of proteins, peptides, and their posttranslational modifications. The structure of the topics discussed in this book chapter is conveniently mapped on the scheme of the CE-MS system itself, starting from sample preconcentration and injection techniques and finishing with mass analyzer considerations. After going through the technical considerations, a variety of relevant applications for this analytical approach are presented, including posttranslational modifications analysis, clinical biomarker discovery, and its growing use in the biotechnological industry.


Asunto(s)
Electroforesis Capilar , Proteómica , Espectrometría de Masas , Péptidos , Proteínas
9.
Anal Chem ; 92(6): 4292-4300, 2020 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-32107919

RESUMEN

Size-exclusion chromatography employing aqueous mobile phases with volatile salts at neutral pH combined with electrospray-ionization mass spectrometry (SEC-ESI-MS) is a useful tool to study proteins in their native state. However, whether the applied eluent conditions actually prevent protein-stationary phase interactions, and/or protein denaturation, often is not assessed. In this study, the effects of volatile mobile phase additives on SEC retention and ESI of proteins were thoroughly investigated. Myoglobin was used as the main model protein, and eluents of varying ionic strength and pH were applied. The degree of interaction between protein and stationary phase was evaluated by calculating the SEC distribution coefficient. Protein-ion charge state distributions obtained during offline and online native ESI-MS were used to monitor alterations in protein structure. Interestingly, most of the supposedly mild eluent compositions induced nonideal SEC behavior and/or protein unfolding. SEC experiments revealed that the nature, ionic strength, and pH of the eluent affected protein retention. Protein-stationary phase interactions were effectively avoided using ammonium acetate at ionic strengths above 0.1 M. Direct-infusion ESI-MS showed that the tested volatile eluent salts seem to follow the Hofmeister series: no denaturation was induced using ammonium acetate (kosmotropic), whereas ammonium formate and bicarbonate (both chaotropic) caused structural changes. Using a mobile phase of 0.2 M ammonium acetate (pH 6.9), several proteins (i.e., myoglobin, carbonic anhydrase, and cytochrome c) could be analyzed by SEC-ESI-MS using different column chemistries without compromising their native state. Overall, with SEC-ESI-MS, the effect of nonspecific interactions between protein and stationary phase on the protein structure can be studied, even revealing gradual structural differences along a peak.


Asunto(s)
Cromatografía en Gel , Mioglobina/análisis , Animales , Corazón , Caballos , Concentración de Iones de Hidrógeno , Desnaturalización Proteica , Espectrometría de Masa por Ionización de Electrospray
10.
J Sep Sci ; 43(9-10): 1678-1727, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32096604

RESUMEN

The proliferation of increasingly more sophisticated analytical separation systems, often incorporating increasingly more powerful detection techniques, such as high-resolution mass spectrometry, causes an urgent need for highly efficient data-analysis and optimization strategies. This is especially true for comprehensive two-dimensional chromatography applied to the separation of very complex samples. In this contribution, the requirement for chemometric tools is explained and the latest developments in approaches for (pre-)processing and analyzing data arising from one- and two-dimensional chromatography systems are reviewed. The final part of this review focuses on the application of chemometrics for method development and optimization.

11.
Anal Chem ; 91(5): 3277-3285, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-30682252

RESUMEN

A novel analytical method based on hybrid trapped ion mobility spectrometry-time-of-flight mass spectrometry (TIMS-TOFMS) has been developed to achieve fast enantiomeric separation of amino acids (AAs). Resolution of chiral AAs was achieved by forming diastereomers through derivatization with the chiral agent (+)-1-(9-fluorenyl)ethyl chloroformate (FLEC), avoiding the use of reference compounds. Electrospray ionization (ESI) in positive mode yielded sodiated FLEC-AAs ions of which the diastereomers could be separated by TIMS. The effect of other alkali metal ions (such as Li and K) on the enantioselectivity was studied, but chiral discrimination was only observed for Na. TIMS conditions, including voltage ramp, ramp time, and accumulation time were optimized for each AA, and collision cross sections (CCSs) were determined for all diastereomers. The migration order of the DL enantiomers was found to be dependent on the structure of the AA. The resulting TIMS resolution (K0/ΔK0) for the FLEC-AA diastereomers on average was 115, requiring a mobility (K0) difference of about 0.009 cm2/(V s) to achieve 50%-valley separation. From the 21 AAs studied, enantiomer separation was achieved for 17 AAs with mobility differences ranging from 0.009 for lysine up to 0.061 cm2/(V s) for asparagine. Moreover, the presented methodology provided mutual separation of various AAs, allowing chiral analysis of multiple AAs simultaneously which may be challenging with previous enantioselective IMS approaches. It appeared possible to fully resolve all studied DL-AAs using three distinct TIMS methods, resulting in a total MS run time of about 3 min (1 min per method) and a total analysis time (including derivatization) of less than 15 min. The method demonstrated capable to determine enantiomeric ratios down to 2.5% with detection limits for the D enantiomers in the nanomolar range. This new TIMS-based methodology opens up possibilities for easy and fast analysis of AA enantiomers.

12.
Anal Chem ; 91(16): 10458-10466, 2019 08 20.
Artículo en Inglés | MEDLINE | ID: mdl-31373797

RESUMEN

High-throughput screening platforms for the identification of bioactive compounds in mixtures have become important tools in the drug discovery process. Miniaturization of such screening systems may overcome problems associated with small sample volumes and enhance throughput and sensitivity. Here we present a new screening platform, coined picofractionation analytics, which encompasses microarray bioassays and mass spectrometry (MS) of components from minute amounts of samples after their nano liquid chromatographic (nanoLC) separation. Herein, nanoLC was coupled to a low-volume liquid dispenser equipped with pressure-fed solenoid valves, enabling 50-nL volumes of column effluent (300 nL/min) to be discretely deposited on a glass slide. The resulting fractions were dried and subsequently bioassayed by sequential printing of nL-volumes of reagents on top of the spots. Unwanted evaporation of bioassay liquids was circumvented by employing mineral oil droplets. A fluorescence microscope was used for assay readout in kinetic mode. Bioassay data were correlated to MS data obtained using the same nanoLC conditions in order to assign bioactives. The platform provides the possibility of freely choosing a wide diversity of bioassay formats, including those requiring long incubation times. The new method was compared to a standard bioassay approach, and its applicability was demonstrated by screening plasmin inhibitors and fibrinolytic bioactives from mixtures of standards and snake venoms, revealing active peptides and coagulopathic proteases.


Asunto(s)
Antifibrinolíticos/aislamiento & purificación , Bioensayo , Cromatografía Liquida/métodos , Fibrinolíticos/aislamiento & purificación , Nanotecnología/métodos , Péptido Hidrolasas/aislamiento & purificación , Animales , Fraccionamiento Químico/instrumentación , Fraccionamiento Químico/métodos , Cromatografía Liquida/instrumentación , Humanos , Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Nanotecnología/instrumentación , Péptido Hidrolasas/análisis , Venenos de Serpiente/química , Serpientes/metabolismo
13.
Electrophoresis ; 40(1): 165-179, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30232802

RESUMEN

In the field of metabolomics, CE-MS is now recognized as a strong analytical technique for the analysis of (highly) polar and charged metabolites in a wide range of biological samples. Over the past few years, significant attention has been paid to the design and improvement of CE-MS approaches for (large-scale) metabolic profiling studies and for establishing protocols in order to further expand the role of CE-MS in metabolomics. In this paper, which is a follow-up of a previous review paper covering the years 2014-2016 (Electrophoresis 2017, 38, 190-202), main advances in CE-MS approaches for metabolomics studies are outlined covering the literature from July 2016 to June 2018. Aspects like developments in interfacing designs and data analysis tools for improving the performance of CE-MS for metabolomics are discussed. Representative examples highlight the utility of CE-MS in the fields of biomedical, clinical, microbial, and plant metabolomics. A complete overview of recent CE-MS-based metabolomics studies is given in a table, which provides information on sample type and pretreatment, capillary coatings and MS detection mode. Finally, some general conclusions and perspectives are given.


Asunto(s)
Electroforesis Capilar , Espectrometría de Masas , Metabolómica , Animales , Humanos , Metaboloma , Ratones
14.
Electrophoresis ; 40(18-19): 2277-2284, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30951206

RESUMEN

A CZE method was validated and implemented for fast and accurate in-process determination of adenovirus concentrations of downstream process samples obtained during manufacturing of adenovirus vector-based vaccines. An analytical-quality-by-design approach was embraced for method development, method implementation, and method maintenance. CZE provided separation of adenovirus particles from sample matrix components, such as cell debris, residual DNA and proteins. The intermediate precision of the virus particle concentration was 6.9% RSD and the relative bias was 2.3%. In comparison, the CZE method is intended to replace a quantitative polymerase chain reaction method which requires three replicates in three analytical runs to achieve an intermediate precision of 8.1% RSD. Given that, in addition, the time from sampling till reporting results of the CZE method was less than 2 h, whereas quantitative polymerase chain reaction requires 3 days, it follows that the CZE method enables faster processing times in downstream processing.


Asunto(s)
Adenoviridae , Electroforesis Capilar/métodos , Virión , Adenoviridae/química , Adenoviridae/aislamiento & purificación , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados , Proyectos de Investigación , Vacunas Virales/análisis , Vacunas Virales/química , Virión/química , Virión/aislamiento & purificación , Cultivo de Virus
15.
J Proteome Res ; 17(11): 3791-3800, 2018 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-30226781

RESUMEN

Top-down proteomics is an emerging analytical strategy to characterize combinatorial protein post-translational modifications (PTMs). However, sample complexity and small mass differences between chemically closely related proteoforms often limit the resolution attainable by separations employing a single liquid chromatographic (LC) principle. In particular, for ultramodified proteins like histones, extensive and time-consuming fractionation is needed to achieve deep proteoform coverage. Herein, we present the first online nanoflow comprehensive two-dimensional liquid chromatography (nLC×LC) platform top-down mass spectrometry analysis of histone proteoforms. The described two-dimensional LC system combines weak cation exchange chromatography under hydrophilic interaction LC conditions (i.e., charge- and hydrophilicity-based separation) with reversed phase liquid chromatography (i.e., hydrophobicity-based separation). The two independent chemical selectivities were run at nanoflows (300 nL/min) and coupled online with high-resolution mass spectrometry employing ultraviolet photodissociation (UVPD-HRMS). The nLC×LC workflow increased the number of intact protein masses observable relative to one-dimensional approaches and allowed characterization of hundreds of proteoforms starting from limited sample quantities (∼1.5 µg).


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Cromatografía de Fase Inversa/métodos , Histonas/aislamiento & purificación , Procesamiento Proteico-Postraduccional , Proteómica/métodos , Cromatografía por Intercambio Iónico/instrumentación , Cromatografía de Fase Inversa/instrumentación , Mezclas Complejas/química , Células HeLa , Histonas/química , Histonas/clasificación , Histonas/metabolismo , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Proteómica/instrumentación , Espectrofotometría Ultravioleta/instrumentación , Espectrofotometría Ultravioleta/métodos , Electricidad Estática , Espectrometría de Masas en Tándem/instrumentación , Espectrometría de Masas en Tándem/métodos
16.
Anal Chem ; 90(11): 6601-6609, 2018 06 05.
Artículo en Inglés | MEDLINE | ID: mdl-29722972

RESUMEN

Recent progress in top-down proteomics has driven the demand for chromatographic methods compatible with mass spectrometry (MS) that can separate intact proteins. Hydrophilic interaction liquid chromatography (HILIC) has recently shown good potential for the characterization of glycoforms of intact proteins. In the present study, we demonstrate that HILIC can separate a wide range of proteins exhibiting orthogonal selectivity with respect to reversed-phase LC (RPLC). However, the application of HILIC to the analysis of low abundance proteins (e.g., in proteomics analysis) is hampered by low volume loadability, hindering down-scaling of the method to column diameters below 2.1 mm. Moreover, HILIC-MS sensitivity is decreased due to ion suppression from the trifluoroacetic acid (TFA) often used as the ion-pair agent to improve the selectivity and efficiency in the analysis of glycoproteins. Here, we introduce a capillary-based HILIC-MS method that overcomes these problems. Our method uses RPLC trap-columns to load and inject the sample, circumventing issues of protein solubility and volume loadability in capillary columns (200 µm ID). The low flow rates and use of a dopant gas in the electrospray interface improve protein-ionization efficiencies and reduce suppression by TFA. Overall, this allows the separation and detection of small protein quantities (down to 5 ng injected on column) as indicated by the analysis of a mixture of model proteins. The potential of the new capillary HILIC-MS is demonstrated by the analysis of a complex cell lysate.


Asunto(s)
Proteínas/análisis , Proteómica , Algoritmos , Cromatografía Liquida , Interacciones Hidrofóbicas e Hidrofílicas , Espectrometría de Masas , Ácido Trifluoroacético/química
17.
Anal Bioanal Chem ; 410(30): 7837-7848, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30328504

RESUMEN

Monoclonal antibodies (mAbs) and antibody-drug conjugates (ADCs) are highly potent biopharmaceuticals designed for targeted cancer therapies. mAbs and ADCs can undergo modifications during production and storage which may affect binding to target receptors, potentially altering drug efficacy. In this work, liquid chromatography was coupled online to surface plasmon resonance (LC-SPR) to allow label-free affinity evaluation of mAb and ADC sample constituents (size and charge variants), under near-native conditions. Trastuzumab and its ADC trastuzumab emtansine (T-DM1) were used as a test sample and were analyzed by aqueous size-exclusion chromatography (SEC)-SPR before and after exposure to aggregate-inducing conditions. SEC-SPR allowed separation of the formed aggregates and measurement of their affinity towards the ligand-binding domain of the human epidermal growth factor receptor 2 (HER2) receptor immobilized on the surface of the SPR sensor chip. The monomer and aggregates of the mAb and ADC were shown to have similar antigen affinity. Conjugation of drugs to trastuzumab appeared to accelerate the aggregate formation. In addition, cation-exchange chromatography (CEX) was coupled to SPR enabling monitoring the maximum ligand-analyte binding capacity (Rmax) of individual charge variants present in mAbs. Deamidated species and lysine variants in trastuzumab sample were separated but did not show different binding affinities to the immobilized HER2-binding domain. In order to allow protein variant assignment, parallel MS detection was added to the LC-SPR setup using a column effluent split. The feasibility of the LC-MS/SPR system was demonstrated by analysis of trastuzumab and T-DM1 providing information on antibody glycoforms and/or determination of the drug-to-antibody ratio (DAR), while simultaneously monitoring binding of eluting species to HER2. Graphical abstract ᅟ.


Asunto(s)
Anticuerpos Monoclonales/química , Afinidad de Anticuerpos , Ado-Trastuzumab Emtansina , Técnicas Biosensibles/métodos , Cromatografía Liquida/métodos , Composición de Medicamentos , Espectrometría de Masas , Maitansina/análogos & derivados , Maitansina/química , Tamaño de la Partícula , Resonancia por Plasmón de Superficie/métodos , Trastuzumab/química
18.
Anal Bioanal Chem ; 410(20): 4979-4990, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29808298

RESUMEN

The potential of capillary electrophoresis (CE) with ultraviolet (UV)-excited fluorescence detection for sensitive chiral analysis of amino acids (AAs) was investigated. DL-AAs were derivatized with 9-fluorenylmethoxycarbonyl chloride (FMOC)-Cl to allow their fluorescence detection and enhance enantioseparation. Fluorescence detection was achieved employing optical fibers, leading UV excitation light (< 300 nm) from a Xe-Hg lamp to the capillary window, and fluorescence emission to a spectrograph equipped with a charge-coupled device (CCD). Signal averaging over time and emission wavelength intervals was carried out to improve the signal-to-noise ratio of the FMOC-AAs. A background electrolyte (BGE) of 40 mM sodium tetraborate (pH 9.5), containing 15% isopropanol (v/v), 30 mM sodium dodecyl sulfate (SDS), and 30 mM ß-cyclodextrin (ß-CD), was found optimal for AA chemo- and enantioseparation. Enantioresolutions of 1.0 or higher were achieved for 16 proteinogenic DL-AAs. Limits of detection (LODs) were in the 10-100-nM range (injected concentration) for the D-AA enantiomers, except for FMOC-D-tryptophan (536 nM) which showed intramolecular fluorescence quenching. Linearity (R2 > 0.997) and repeatability for peak height (relative standard deviations (RSDs) < 7.0%; n = 5) and electrophoretic mobility (RSDs < 0.6%; n = 5) of individual AA enantiomers were established for chiral analysis of DL-AA mixtures. The applicability of the method was investigated by the analysis of cerebrospinal fluid (CSF). Next to L-AAs, endogenous levels of D-glutamine and D-aspartic acid could be measured in CSF revealing enantiomeric ratios of 0.35 and 19.6%, respectively. This indicates the method's potential for the analysis of low concentrations of D-AAs in presence of abundant L-AAs.


Asunto(s)
Aminoácidos/líquido cefalorraquídeo , Electroforesis Capilar/métodos , Fluorenos/análisis , Colorantes Fluorescentes/análisis , Aminoácidos/análisis , Fluorescencia , Humanos , Límite de Detección , Espectrometría de Fluorescencia/métodos , Estereoisomerismo
19.
Anal Bioanal Chem ; 410(23): 5751-5763, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30090989

RESUMEN

To better understand envenoming and to facilitate the development of new therapies for snakebite victims, rapid, sensitive, and robust methods for assessing the toxicity of individual venom proteins are required. Metalloproteinases comprise a major protein family responsible for many aspects of venom-induced haemotoxicity including coagulopathy, one of the most devastating effects of snake envenomation, and is characterized by fibrinogen depletion. Snake venoms are also known to contain anti-fibrinolytic agents with therapeutic potential, which makes them a good source of new plasmin inhibitors. The protease plasmin degrades fibrin clots, and changes in its activity can lead to life-threatening levels of fibrinolysis. Here, we present a methodology for the screening of plasmin inhibitors in snake venoms and the simultaneous assessment of general venom protease activity. Venom is first chromatographically separated followed by column effluent collection onto a 384-well plate using nanofractionation. Via a post-column split, mass spectrometry (MS) analysis of the effluent is performed in parallel. The nanofractionated venoms are exposed to a plasmin bioassay, and the resulting bioassay activity chromatograms are correlated to the MS data. To study observed proteolytic activity of venoms in more detail, venom fractions were exposed to variants of the plasmin bioassay in which the assay mixture was enriched with zinc or calcium ions, or the chelating agents EDTA or 1,10-phenanthroline were added. The plasmin activity screening system was applied to snake venoms and successfully detected compounds exhibiting antiplasmin (anti-fibrinolytic) activities in the venom of Daboia russelii, and metal-dependent proteases in the venom of Crotalus basiliscus. Graphical abstract ᅟ.


Asunto(s)
Antifibrinolíticos/análisis , Fibrinolisina/antagonistas & inhibidores , Espectrometría de Masas/instrumentación , Péptido Hidrolasas/análisis , Proteínas de Reptiles/análisis , Venenos de Víboras/química , Venenos de Víboras/enzimología , Viperidae , Animales , Antifibrinolíticos/farmacología , Fraccionamiento Químico/instrumentación , Cromatografía Liquida/instrumentación , Evaluación Preclínica de Medicamentos/instrumentación , Diseño de Equipo , Fibrinolisina/metabolismo , Humanos , Nanotecnología/instrumentación , Péptido Hidrolasas/farmacología , Proteómica/métodos , Proteínas de Reptiles/farmacología , Viperidae/metabolismo
20.
J Sep Sci ; 41(14): 2983-2992, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29785784

RESUMEN

Chiral analysis of dl-amino acids was achieved by micellar electrokinetic chromatography coupled with UV-excited fluorescence detection. The fluorescent reagent (+)-1-(9-fluorenyl)ethyl chloroformate was employed as chiral amino acid derivatizing agent and sodium dodecyl sulfate served as pseudo-stationary phase for separating the formed amino acid diastereomers. Sensitive analysis of (+)-1-(9-fluorenyl)ethyl chloroformate-amino acids was achieved applying a xenon-mercury lamp for ultraviolet excitation, and a spectrograph and charge-coupled device for wavelength-resolved emission detection. Applying signal integration over a 30 nm emission wavelength interval, signal-to-noise ratios for derivatized amino acids were up to 23 times higher as obtained using a standard photomultiplier for detection. The background electrolyte composition (electrolyte, pH, sodium dodecyl sulfate concentration, and organic solvent) was studied in order to attain optimal chemo- and enantioseparation. Enantioseparation of 12 proteinogenic dl-amino acids was achieved with chiral resolutions between 1.2 and 7.9, and detection limits for most derivatized amino acids in the 13-60 nM range (injected concentration). Linearity (coefficients of determination > 0.985) and peak-area and migration-time repeatabilities (relative standard deviations lower than 2.6 and 1.9%, respectively) were satisfactory. The employed fluorescence detection system provided up to 100-times better signal-to-noise ratios for (+)-1-(9-fluorenyl)ethyl chloroformate-amino acids than ultraviolet absorbance detection, showing good potential for d-amino acid analysis.