Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37634148

RESUMEN

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/clasificación , Fibrilación Atrial/cirugía , Teorema de Bayes , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia , Método Simple Ciego , Taquicardia/etiología , Resultado del Tratamiento
3.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305503

RESUMEN

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Venas Pulmonares/cirugía , Constricción Patológica/complicaciones , Constricción Patológica/cirugía , Método Simple Ciego , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología
4.
Circulation ; 143(1): 7-17, 2021 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-33073614

RESUMEN

BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. METHODS: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. RESULTS: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. CONCLUSIONS: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379.


Asunto(s)
Arritmias Cardíacas/prevención & control , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/normas , Prevención Primaria/métodos , Volumen Sistólico/fisiología , Adulto , Anciano , Arritmias Cardíacas/fisiopatología , Estudios de Cohortes , Muerte Súbita Cardíaca/epidemiología , Desfibriladores/normas , Desfibriladores/tendencias , Desfibriladores Implantables/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
5.
J Card Fail ; 28(8): 1245-1254, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35460884

RESUMEN

BACKGROUND: Patients with heart failure (HF) and reduced ejection fraction suffer from a relapsing and remitting disease course, where early treatment changes may improve outcomes. We assessed the clinical integration and safety of the HeartLogic multisensor index and alerts in HF care. METHODS: The Multiple cArdiac seNsors for mAnaGEment of Heart Failure (MANAGE-HF) study enrolled 200 patients with HF and reduced ejection fraction (<35%), New York Heart Association functional class II-III symptoms, implanted with a cardiac resynchronization therapy-defibrillator or and implantable cardioverter defibrillator, who had either a hospitalization for HF within 12 months or unscheduled visit for HF exacerbation within 90 days or an elevated natriuretic peptide concentration (brain natriuretic peptide [BNP] of ≥150 pg/mL or N-terminal pro-BNP [NT-proBNP] of ≥600 pg/mL). This phase included the development of an alert management guide and evaluated changes in medical treatment, natriuretic peptide levels, and safety. RESULTS: The mean age of participants was 67 years, 68% were men, 81% were White, and 61% had a HF hospitalization in prior 12 months. During follow-up, there were 585 alert cases with an average of 1.76 alert cases per patient-year. HF medications were augmented during 74% of the alert cases. HF treatment augmentation within 2 weeks from an initial alert was associated with more rapid recovery of the HeartLogic Index. Five serious adverse events (0.015 per patient-year) occurred in relation to alert-prompted medication change. NTproBNP levels decreased from median of 1316 pg/mL at baseline to 743 pg/mL at 12 months (P < .001). CONCLUSIONS: HeartLogic alert management was safely implemented in HF care and may optimize HF management. This phase supports further evaluation in larger studies. TRIAL REGISTRATION: ClinicalTrials.gov (NCT03237858).


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Algoritmos , Femenino , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Péptido Natriurético Encefálico/uso terapéutico , Fragmentos de Péptidos , Volumen Sistólico
6.
Eur Heart J ; 42(17): 1676-1684, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33417692

RESUMEN

AIMS: The benefit of prophylactic implantable cardioverter-defibrillator (ICD) is not uniform due to differences in the risk of life-threatening ventricular tachycardia (VT)/ventricular fibrillation (VF) and non-arrhythmic mortality. We aimed to develop an ICD benefit prediction score that integrates the competing risks. METHODS AND RESULTS: The study population comprised all 4531 patients enrolled in the MADIT trials. Best-subsets Fine and Gray regression analysis was used to develop prognostic models for VT (≥200 b.p.m.)/VF vs. non-arrhythmic mortality (defined as death without prior sustained VT/VF). Eight predictors of VT/VF (male, age < 75 years, prior non-sustained VT, heart rate > 75 b.p.m., systolic blood pressure < 140 mmHg, ejection fraction ≤ 25%, myocardial infarction, and atrialarrhythmia) and 7 predictors of non-arrhythmic mortality (age ≥ 75 years, diabetes mellitus, body mass index < 23 kg/m2, ejection fraction ≤ 25%, New York Heart Association ≥II, ICD vs. cardiac resynchronization therapy with defibrillator, and atrial arrhythmia) were identified. The two scores were combined to create three MADIT-ICD benefit groups. In the highest benefit group, the 3-year predicted risk of VT/VF was three-fold higher than the risk of non-arrhythmic mortality (20% vs. 7%, P < 0.001). In the intermediate benefit group, the difference in the corresponding predicted risks was attenuated (15% vs. 9%, P < 0.01). In the lowest benefit group, the 3-year predicted risk of VT/VF was similar to the risk of non-arrhythmic mortality (11% vs. 12%, P = 0.41). A personalized ICD benefit score was developed based on the distribution of the two competing risks scores in the study population (https://is.gd/madit). Internal and external validation confirmed model stability. CONCLUSIONS: We propose the novel MADIT-ICD benefit score that predicts the likelihood of prophylactic ICD benefit through personalized assessment of the risk of VT/VF weighed against the risk of non-arrhythmic mortality.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Anciano , Arritmias Cardíacas/terapia , Humanos , Masculino , Factores de Riesgo , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia
7.
Europace ; 23(3): 329-344, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33555020

RESUMEN

AIMS: The risk of developing atrial fibrillation (AF) and its complications continues to increase, despite good progress in preventing AF-related strokes. METHODS AND RESULTS: This article summarizes the outcomes of the 7th Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA) held in Lisbon in March 2019. Sixty-five international AF specialists met to present new data and find consensus on pressing issues in AF prevention, management and future research to improve care for patients with AF and prevent AF-related complications. This article is the main outcome of an interactive, iterative discussion between breakout specialist groups and the meeting plenary. AF patients have dynamic risk profiles requiring repeated assessment and risk-based therapy stratification to optimize quality of care. Interrogation of deeply phenotyped datasets with outcomes will lead to a better understanding of the cardiac and systemic effects of AF, interacting with comorbidities and predisposing factors, enabling stratified therapy. New proposals include an algorithm for the acute management of patients with AF and heart failure, a call for a refined, data-driven assessment of stroke risk, suggestions for anticoagulation use in special populations, and a call for rhythm control therapy selection based on risk of AF recurrence. CONCLUSION: The remaining morbidity and mortality in patients with AF needs better characterization. Likely drivers of the remaining AF-related problems are AF burden, potentially treatable by rhythm control therapy, and concomitant conditions, potentially treatable by treating these conditions. Identifying the drivers of AF-related complications holds promise for stratified therapy.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Anticoagulantes/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Consenso , Humanos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
8.
Curr Neurol Neurosci Rep ; 21(12): 72, 2021 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-34817719

RESUMEN

PURPOSE OF REVIEW: Concussion is a complex injury that may present as a variety of clinical profiles, which can overlap and reinforce one another. This review summarizes the medical management of patients with concussion and persistent post-concussive symptoms (PPCS). RECENT FINDINGS: Management of concussion and PPCS relies on identifying underlying symptom generators. Treatment options include sub-symptom threshold aerobic exercise, cervical physical therapy, vestibular therapy, vision therapy, cognitive rehabilitation, cognitive behavioral therapy, pharmacological management, or a combination of treatments. Evidence-based treatments have emerged to treat post-concussion symptom generators for sport-related concussion and for patients with PPCS.


Asunto(s)
Conmoción Encefálica , Terapia Cognitivo-Conductual , Síndrome Posconmocional , Conmoción Encefálica/terapia , Ejercicio Físico , Humanos , Neurólogos , Síndrome Posconmocional/diagnóstico , Síndrome Posconmocional/terapia
9.
Curr Neurol Neurosci Rep ; 21(12): 70, 2021 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-34817724

RESUMEN

PURPOSE OF REVIEW: Concussion produces a variety of signs and symptoms. Most patients recover within 2-4 weeks, but a significant minority experiences persistent post-concussive symptoms (PPCS), some of which may be from associated cervical or persistent neurologic sub-system (e.g., vestibular) dysfunction. This review provides evidence-based information for a pertinent history and physical examination of patients with concussion. RECENT FINDINGS: The differential diagnosis of PPCS is based on the mechanism of injury, a thorough medical history and concussion-pertinent neurological and cervical physical examinations. The concussion physical examination focuses on elements of autonomic function, oculomotor and vestibular function, and the cervical spine. Abnormalities identified on physical examination can inform specific forms of rehabilitation to help speed recovery. Emerging data show that there are specific symptom generators after concussion that can be identified by a thorough history, a pertinent physical examination, and adjunct tests when indicated.


Asunto(s)
Conmoción Encefálica , Síndrome Posconmocional , Conmoción Encefálica/complicaciones , Conmoción Encefálica/diagnóstico , Humanos , Neurólogos , Síndrome Posconmocional/diagnóstico
10.
Europace ; 22(2): 225-231, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31665276

RESUMEN

AIMS: Clinical practice guidelines do not recommend discontinuation of long-term oral anticoagulation in patients with a high stroke risk after catheter ablation for atrial fibrillation (AF). Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the long-term outcomes of combining catheter ablation procedures for AF and LAAC from multicentre registries. METHODS AND RESULTS: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 142 subjects at 11 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful LAAC was achieved in 99.3% of patients. The 30-day device and/or procedure-related serious adverse event rate was 2.1%. After a mean follow-up time of 726 ± 91 days, 92% of patients remained off oral anticoagulation. The rates of the composite endpoint of ischaemic stroke/transient ischaemic attack/systemic thromboembolism were 1.09 per 100 patient-years (100-PY); and for non-procedural major bleeding were 1.09 per 100-PY. These represent relative reductions of 84% and 70% vs. expected rates per risk scores. CONCLUSION: The long-term outcomes from these international, multicentre registries show efficacy for all-cause stroke prevention and a significant reduction in late bleeding events in a population of high stroke risk post-ablation patients who have been withdrawn from oral anticoagulation.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Isquemia Encefálica , Ablación por Catéter , Accidente Cerebrovascular , Anticoagulantes , Asia/epidemiología , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Australia , Europa (Continente) , Humanos , Medio Oriente , Estudios Prospectivos , Sistema de Registros , Federación de Rusia , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
11.
Europace ; 22(11): 1742-1758, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32725140

RESUMEN

The European Union (EU) General Data Protection Regulation (GDPR) imposes legal responsibilities concerning the collection and processing of personal information from individuals who live in the EU. It has particular implications for the remote monitoring of cardiac implantable electronic devices (CIEDs). This report from a joint Task Force of the European Heart Rhythm Association and the Regulatory Affairs Committee of the European Society of Cardiology (ESC) recommends a common legal interpretation of the GDPR. Manufacturers and hospitals should be designated as joint controllers of the data collected by remote monitoring (depending upon the system architecture) and they should have a mutual contract in place that defines their respective roles; a generic template is proposed. Alternatively, they may be two independent controllers. Self-employed cardiologists also are data controllers. Third-party providers of monitoring platforms may act as data processors. Manufacturers should always collect and process the minimum amount of identifiable data necessary, and wherever feasible have access only to pseudonymized data. Cybersecurity vulnerabilities have been reported concerning the security of transmission of data between a patient's device and the transceiver, so manufacturers should use secure communication protocols. Patients need to be informed how their remotely monitored data will be handled and used, and their informed consent should be sought before their device is implanted. Review of consent forms in current use revealed great variability in length and content, and sometimes very technical language; therefore, a standard information sheet and generic consent form are proposed. Cardiologists who care for patients with CIEDs that are remotely monitored should be aware of these issues.


Asunto(s)
Cardiología , Comités Consultivos , Seguridad Computacional , Electrónica , Humanos , Monitoreo Fisiológico
12.
Pacing Clin Electrophysiol ; 43(4): 412-417, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32067233

RESUMEN

BACKGROUND: Limited studies are available on the clinical significance of left ventricular (LV) lead polarity in patients undergoing cardiac resynchronization therapy (CRT), with a recent study suggesting better outcomes with LV true bipolar pacing. OBJECTIVE: We aimed to determine whether true bipolar LV pacing is associated with reduced mortality in a large, real-life CRT cohort, followed by remote monitoring. METHODS: We analyzed de-identified device data from CRT patients followed by the Boston Scientific LATITUDE remote monitoring database system. Patients with LV bipolar leads paced between the LV ring and LV tip were identified as true bipolar and those with LV bipolar leads paced between LV tip or LV ring and right ventricular (RV) coil were identified as extended bipolar. Patients with unipolar leads were identified as unipolar. RESULTS: Of the 59 046 patients included in the study, 2927 had unipolar pacing, 34 390 had extended bipolar pacing, and 21 729 had true bipolar pacing. LV true bipolar pacing was associated with a significant 30% lower risk of all-cause mortality as compared to unipolar pacing (hazards ratio [HR] = 0.70, 95% CI: 0.62-0.79, P < .001), after adjustment for age, gender, LV lead impedance, LV pacing threshold, and BIV pacing percentage <95%. Extended bipolar LV pacing was also associated with 24% lower risk of all-cause mortality when compared to unipolar LV pacing (HR = 0.76, 95% CI: 0.68-0.85; P < .001). However, there were no differences in outcomes between true bipolar and extended bipolar LV pacing (HR = 0.97, 95% CI: 0.93-1.01; P = .198). CONCLUSION: True bipolar or extended bipolar LV pacing is associated with a lower risk of mortality in CRT patients as compared to unipolar LV pacing.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tasa de Supervivencia
13.
J Cardiovasc Electrophysiol ; 30(7): 1066-1077, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30938894

RESUMEN

BACKGROUND: Remote monitoring of implantable cardioverter-defibrillators has been associated with reduced rates of all-cause rehospitalizations and mortality among device recipients, but long-term economic benefits have not been studied. METHODS AND RESULTS: An economic model was developed using the PREDICT RM database comparing outcomes with and without remote monitoring. The database included patients ages 65 to 89 who received a Boston Scientific device from 2006 to 2010. Parametric survival equations were derived for rehospitalization and mortality to predict outcomes over a maximum time horizon of 25 years. The analysis assessed rehospitalization, mortality, and the cost-effectiveness (expressed as the incremental cost per quality-adjusted life year) of remote monitoring versus no remote monitoring. Remote monitoring was associated with reduced mortality; average life expectancy and average quality-adjusted life years increased by 0.77 years and 0.64, respectively (6.85 life years and 5.65 quality-adjusted life years). When expressed per patient-year, remote monitoring patients had fewer subsequent rehospitalizations (by 0.08 per patient-year) and lower hospitalization costs (by $554 per patient year). With longer life expectancies, remote monitoring patients experienced an average of 0.64 additional subsequent rehospitalizations with increased average lifetime hospitalization costs of $2784. Total costs of outpatient and physician claims were higher with remote monitoring ($47 515 vs $42 792), but average per patient-year costs were lower ($6232 vs $6244). The base-case incremental cost-effectiveness ratio was $10 752 per quality-adjusted life year, making remote monitoring high-value care. CONCLUSION: Remote monitoring is a cost-effective approach for the lifetime management of patients with implantable cardioverter-defibrillators.


Asunto(s)
Arritmias Cardíacas/economía , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/economía , Cardioversión Eléctrica/economía , Costos de la Atención en Salud , Tecnología de Sensores Remotos/economía , Telemetría/economía , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Análisis Costo-Beneficio , Bases de Datos Factuales , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/mortalidad , Femenino , Humanos , Masculino , Medicare/economía , Modelos Económicos , Readmisión del Paciente/economía , Valor Predictivo de las Pruebas , Años de Vida Ajustados por Calidad de Vida , Sistema de Registros , Tecnología de Sensores Remotos/instrumentación , Telemetría/instrumentación , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
14.
J Cardiovasc Electrophysiol ; 29(7): 973-978, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29722469

RESUMEN

INTRODUCTION: Pericardial effusion/tamponade (PE/PT) is a rare but serious complication following left atrial appendage closure (LAAC). It may be speculated that LAA contraction during sinus rhythm (SR) exerts mechanical force on the device that eventually leads to PE. We sought to determine the incidence and predictors of PE following LAAC using Watchman with special emphasis on the underlying heart rhythm during implant. METHODS AND RESULTS: From 47 centers in 13 European countries 1,020 patients underwent LAAC and data on baseline rhythm were available from 1,010 patients (mean age 73 ± 9 years, 60% male, median CHA2DS2-VASc = 4). Data were collected via electronic case report forms. A Cox proportional hazard model was calculated adjusting for multiple variables: age, gender, number of recaptures, and device oversizing. During implant, 41% and 59% of patients were in SR and atrial fibrillation (AF), respectively. PE/PT rate was significantly lower in patients implanted during AF at day 30 postimplant (n = 1; 0.2% vs. n = 6; 1.5%; P = 0.02). No PE requiring intervention occurred in the AF group compared to 5 events (1.2%) in the SR group (P = 0.01). While univariate analysis identified SR and gender as predictors for PE/tamponade, multivariate analysis only showed a statistical trend for both variables. CONCLUSION: The overall incidence of PE/PT was very low after LAAC using Watchman. Although SR was not identified as an independent predictor of PE/PT, all events requiring intervention occurred in patients with SR. It may be advisable to perform an extended echocardiographic follow-up in that patient population.


Asunto(s)
Apéndice Atrial/cirugía , Procedimientos Endovasculares/efectos adversos , Frecuencia Cardíaca/fisiología , Derrame Pericárdico/epidemiología , Derrame Pericárdico/fisiopatología , Dispositivos de Cierre Vascular/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Procedimientos Endovasculares/tendencias , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Derrame Pericárdico/diagnóstico por imagen , Sistema de Registros , Dispositivos de Cierre Vascular/tendencias
15.
Europace ; 20(6): 949-955, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-29106523

RESUMEN

Aims: Long-term results from catheter ablation therapy for atrial fibrillation (AF) remain uncertain and clinical practice guidelines recommend continuation of long-term oral anticoagulation in patients with a high stroke risk. Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the initial results of combining catheter ablation procedures for AF and LAAC in a multicentre registry. Methods and results: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 139 subjects at 10 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful Watchman implantation was achieved in 100% of patients. The overall 30-day serious adverse event (SAE) rate was 8.7%, with the device and/or procedure-related SAE rate of 1.4%. One pericardial effusion required percutaneous drainage, but there were no strokes, device embolization, or deaths at 30 days. The 30-day bleeding SAE rate was 2.9% with 55% of patients prescribed NOAC and 38% taking warfarin post-procedure. Conclusion: The outcomes from these international, multicentre registries support the feasibility and safety of performing combined procedures of ablation and Watchman LAAC for patients with non-valvular AF and high stroke risk. Further data are needed on long-term outcomes for the hybrid technique on all-cause stroke and mortality.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter , Derrame Pericárdico , Complicaciones Posoperatorias/diagnóstico , Hemorragia Posoperatoria/diagnóstico , Implantación de Prótesis , Dispositivo Oclusor Septal , Anciano , Asia/epidemiología , Fibrilación Atrial/epidemiología , Australia/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Europa (Continente)/epidemiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Medio Oriente/epidemiología , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/etiología , Estudios Prospectivos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Sistema de Registros/estadística & datos numéricos , Federación de Rusia/epidemiología
17.
Am Heart J ; 189: 68-74, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28625383

RESUMEN

BACKGROUND: Oral anticoagulants (OACs) reduce stroke risks with nonvalvular atrial fibrillation (AF); however, they are underused because of absolute or relative contraindications due to real or perceived risk of bleeding. Although left atrial appendage closure is increasingly performed in OAC-ineligible patients, this has not been studied in a randomized controlled trial. STUDY OBJECTIVES: The ASAP-TOO study is designed to establish the safety and effectiveness of the Watchman left atrial appendage closure device in patients with nonvalvular AF who are deemed ineligible for OAC. The primary effectiveness end point is the time to first occurrence of ischemic stroke or systemic embolism. The primary safety end point includes all-cause death, ischemic stroke, systemic embolism, or device- or procedural-related event requiring open cardiac surgery or major endovascular intervention. STUDY DESIGN: This is a multinational, multicenter prospective randomized trial. Patients meeting the inclusion criteria with CHA2DS2-VASc score≥2 and who are deemed by 2 study physicians to be unsuitable for OAC will be randomized in a 2:1 allocation ratio to Watchman versus control. Control patients will be prescribed single antiplatelet therapy or no therapy at the discretion of the study physician. Up to 888 randomized subjects will be enrolled from up to 100 global investigational sites. Both device group and control patients will have follow-up visits at 3, 6, and 12months and then every 6months through 60months. SUMMARY: This trial will assess the safety and efficacy of Watchman in this challenging population of high-stroke risk AF patients.


Asunto(s)
Anticoagulantes , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Prótesis e Implantes , Accidente Cerebrovascular/prevención & control , Administración Oral , Fibrilación Atrial/complicaciones , Contraindicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
18.
Europace ; 19(5): 802-807, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-27256416

RESUMEN

AIMS: Patients have increasing comorbidities and competing causes of death with advancing age, raising questions about the effectiveness of the implantable cardioverter defibrillators (ICD) in older age. We therefore investigated the effect of patients' age at initial device implantation on all-cause mortality and on the risk of ICD shocks in single-chamber (V-ICD), dual-chamber (D-ICD), and cardiac resynchronization therapy defibrillator (CRT-D) recipients. METHODS AND RESULTS: We reviewed de-identified records of 67 128 ICD recipients enrolled in the Boston Scientific ALTITUDE database of remote monitored patients [V-ICD (n = 11 422), D-ICD (n = 23 974), and CRT-D (n = 31 732)]. Over a mean follow-up of 2.3 ± 1.4 years, patients in all ICD groups had increased all-cause mortality but decreased risk of defibrillator shocks and/or anti-tachycardia pacing per 10 year increase in age. Compared with the youngest age group (<50 years), patients in the oldest age group (≥80 years) had a 6.8-fold, 5.9-fold, and 3.4-fold increase in all-cause mortality (P < 0.001 for all comparisons) and a 31, 45, and 53% decrease in the risk of ICD shock (P ≤ 0.002 for all comparisons) for the V-ICD, D-ICD, and CRT-D groups, respectively. CONCLUSION: Older recipients of standard and CRT defibrillators have higher mortality but fewer ICD shocks and/or therapies compared with younger patients. These data highly suggest less benefit of ICD therapy with increasing age, presumably because of competing risks of non-arrhythmic mortality. The role of defibrillator therapy in older patients may need to be evaluated with randomized controlled trials.


Asunto(s)
Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Cardioversión Eléctrica/mortalidad , Traumatismos por Electricidad/mortalidad , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Causalidad , Cardioversión Eléctrica/estadística & datos numéricos , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Implantación de Prótesis/estadística & datos numéricos , Estudios Retrospectivos , Factores de Riesgo , Distribución por Sexo , Tasa de Supervivencia , Estados Unidos/epidemiología
19.
Pacing Clin Electrophysiol ; 40(10): 1121-1128, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28727156

RESUMEN

BACKGROUND: The design of pacemaker leads has continued to evolve; ease of lead handling, improved electrical performance, and magnetic resonance imaging (MRI) conditional aspects have become more important, while safety remains critical. The INGEVITY™ family leads was designed to provide MRI conditional aspects, decreased diameter, and improved performance of pacemaker leads. The INGEVITY study is an investigational device exemption trial evaluating the acute and chronic safety and effectiveness of these leads. METHODS: Consecutive patients were included in 77 institutions worldwide, where 1,657 leads (846 right ventricular active fixation leads, 213 right ventricular passive fixation leads, 121 right atrial passive fixation preformed J-leads, and 477 right atrial active fixation leads) were implanted or attempted in 1,060 subjects. RESULTS: At 3-month follow-up, the electrical performance were: mean pacing threshold 0.67 V at 0.5-ms pulse width, pacing impedance 773 ohms, mean P-wave amplitude 4.8 mV, and R-wave amplitude 16.5 ± 6.5 mV. Over a median follow-up of 31 months, 93 subjects died and 33 subjects reported lead-related complications. Lead-related complication-free rate from 0 to 3 months and 3 to 12 months for all leads was 98.4% and 99.7%, respectively. The hazard of lead-related complications was observed to be decelerating over the course of follow-up (Weibull shape = 0.23). The overall lead dislodgment rate observed in the study was 1.3%, the perforation rate was 0.0%, and the pericardial effusion rate was 0.3%. CONCLUSIONS: The clinical performance of the INGEVITY lead demonstrated a high lead-related complication-free rate over 12 months of follow-up and excellent electrical characteristics.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/terapia , Imagen por Resonancia Magnética , Marcapaso Artificial , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento
20.
Eur Heart J ; 37(31): 2465-74, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26822918

RESUMEN

AIMS: Left atrial appendage closure is a non-pharmacological alternative for stroke prevention in high-risk patients with non-valvular atrial fibrillation. The objective of the multicentre EWOLUTION registry was to obtain clinical data on procedural success and complications, and long-term patient outcomes, including bleeding and incidence of stroke/transient ischaemic attack (TIA). Here, we report on the peri-procedural outcomes of up to 30 days. METHODS AND RESULTS: Baseline/implant data are available for 1021 subjects. Subjects in the study were at high risk of stroke (average CHADS2 score: 2.8 ± 1.3, CHA2DS2-VASc: 4.5 ± 1.6) and moderate-to-high risk of bleeding (average HAS-BLED score: 2.3 ± 1.2). Almost half of the subjects (45.4%) had a history of TIA, ischaemic stroke, or haemorrhagic stroke; 62% of patients were deemed unsuitable for novel oral anticoagulant by their physician. The device was successfully deployed in 98.5% of patients with no flow or minimal residual flow achieved in 99.3% of implanted patients. Twenty-eight subjects experienced 31 serious adverse events (SAEs) within 1 day of the procedure. The overall 30-day mortality rate was 0.7%. The most common SAE occurring within 30 days of the procedure was major bleeding requiring transfusion. Incidence of SAEs within 30 days was significantly lower for subjects deemed to be ineligible for oral anticoagulation therapy (OAT) compared with those eligible for OAT (6.5 vs. 10.2%, P = 0.042). CONCLUSION: Left atrial appendage closure with the WATCHMAN device has a high success rate in complete LAAC with low peri-procedural risk, even in a population with a higher risk of stroke and bleeding, and multiple co-morbidities. Improvement in implantation techniques has led to a reduction of peri-procedural complications previously limiting the net clinical benefit of the procedure.


Asunto(s)
Apéndice Atrial , Anticoagulantes , Fibrilación Atrial , Humanos , Sistema de Registros , Accidente Cerebrovascular , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA