Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 390(3): 212-220, 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38231622

RESUMEN

BACKGROUND: The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT) showed a greater benefit with respect to mortality at 5 years among patients who received cardiac-resynchronization therapy (CRT) than among those who received implantable cardioverter-defibrillators (ICDs). However, the effect of CRT on long-term survival is not known. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more (or a paced QRS duration of 200 msec or more) to receive either an ICD alone or a CRT defibrillator (CRT-D). We assessed long-term outcomes among patients at the eight highest-enrolling participating sites. The primary outcome was death from any cause; the secondary outcome was a composite of death from any cause, heart transplantation, or implantation of a ventricular assist device. RESULTS: The trial enrolled 1798 patients, of whom 1050 were included in the long-term survival trial; the median duration of follow-up for the 1050 patients was 7.7 years (interquartile range, 3.9 to 12.8), and the median duration of follow-up for those who survived was 13.9 years (interquartile range, 12.8 to 15.7). Death occurred in 405 of 530 patients (76.4%) assigned to the ICD group and in 370 of 520 patients (71.2%) assigned to the CRT-D group. The time until death appeared to be longer for those assigned to receive a CRT-D than for those assigned to receive an ICD (acceleration factor, 0.80; 95% confidence interval, 0.69 to 0.92; P = 0.002). A secondary-outcome event occurred in 412 patients (77.7%) in the ICD group and in 392 (75.4%) in the CRT-D group. CONCLUSIONS: Among patients with a reduced ejection fraction, a widened QRS complex, and NYHA class II or III heart failure, the survival benefit associated with receipt of a CRT-D as compared with ICD appeared to be sustained during a median of nearly 14 years of follow-up. (RAFT ClinicalTrials.gov number, NCT00251251.).


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Estimación de Kaplan-Meier , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Electrocardiografía , Estudios de Seguimiento , Factores de Tiempo
2.
Am Heart J ; 248: 1-12, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35219715

RESUMEN

BACKGROUND: Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE: The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN: The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION: The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Canadá , Ablación por Catéter/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
3.
Europace ; 24(6): 948-958, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-34964475

RESUMEN

AIMS: Complexity of the ventricular tachycardia (VT) substrate and the size and thickness of infarction area border zones differ based on location of myocardial infarctions (MIs). These differences may translate into heterogeneity in the effectiveness of treatments. This study aims to examine the influence of infarct location on the effectiveness of VT ablation in comparison with escalated pharmacological therapy in patients with prior MI and antiarrhythmic drug (AAD)-refractory VT. METHODS AND RESULTS: VANISH trial participants were categorized based on the presence or absence of an inferior MI scar. Inverse probability of treatment weighted Cox models were calculated for each subgroup. Of 259 randomized patients (median age 69.8 years, 7.0% women), 135 had an inferior MI and 124 had a non-inferior MI. Among patients with an inferior MI, no statistically significant difference in the composite primary outcome of all-cause mortality, appropriate implantable cardioverter-defibrillator (ICD) shock, and VT storm was detected between treatment arms [adjusted hazard ratio (aHR) 0.80, 95% confidence interval (CI) 0.51-1.20]. In contrast, patients with non-inferior MIs had a statistically significant reduction in the incidence of the primary outcome with ablation (aHR 0.48, 95% CI 0.27-0.86). In a sensitivity analysis of anterior MI patients (n = 83), a trend towards a reduction in the primary outcome with ablation was detected (aHR 0.50, 95% CI 0.23-1.09). CONCLUSION: The effectiveness of VT ablation versus escalated AADs varies based on the location of the MI. Patients with MI scars located only in non-inferior regions of the ventricles derive greater benefit from VT ablation in comparison to escalation of AADs in reducing VT-related events.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Infarto del Miocardio , Taquicardia Ventricular , Anciano , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cicatriz/etiología , Femenino , Humanos , Masculino , Infarto del Miocardio/tratamiento farmacológico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
4.
Europace ; 24(7): 1112-1118, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35030257

RESUMEN

AIMS: Catheter ablation is superior to escalated antiarrhythmic drugs among patients with ventricular tachycardia (VT) and prior myocardial infarction (MI). However, it is uncertain whether clinical VT characteristics, should influence choice of therapy. The purpose of this study was to evaluate whether presentation with electrical storm and the clinical VT cycle length predicted response to ablation vs. escalated antiarrhythmic therapy. METHODS AND RESULTS: All patients enrolled in the Ventricular Tachycardia Ablation vs. Escalated Antiarrhythmic Drug Therapy in Ischaemic Heart Disease (VANISH) trial were included. The association between VT cycle length and presentation with electrical storm and the primary outcome of death, subsequent VT storm or appropriate ICD shock was evaluated. Among the study population of 259 patients, escalated antiarrhythmic drug therapy had worse outcomes for those presenting with a VT cycle length >400 ms [<150 b.p.m., 89/259, hazard ratio (HR) 1.7 (1.02-3.13)]. This effect was more pronounced among those taking amiodarone at baseline [HR of 2.22 (1.19-4.16)]. Presentation with VT storm (32/259) did not affect the primary outcome between groups. However, those presenting with VT storm on amiodarone had a trend towards worse outcomes with escalated antiarrhythmic therapy [HR 4.31 (0.55-33.93)]. CONCLUSION: The VT cycle length can influence response to either ablation or escalated drug therapy in patients with VT and prior MI. Those with slow VT had improved outcomes with ablation. Patients presenting with electrical storm demonstrated similar outcomes to the overall trial population, with a trend to benefit of catheter ablation, particularly in those on amiodarone.


Asunto(s)
Amiodarona , Ablación por Catéter , Infarto del Miocardio , Taquicardia Ventricular , Amiodarona/uso terapéutico , Antiarrítmicos/uso terapéutico , Ablación por Catéter/métodos , Humanos , Infarto del Miocardio/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
5.
N Engl J Med ; 375(2): 111-21, 2016 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-27149033

RESUMEN

BACKGROUND: Recurrent ventricular tachycardia among survivors of myocardial infarction with an implantable cardioverter-defibrillator (ICD) is frequent despite antiarrhythmic drug therapy. The most effective approach to management of this problem is uncertain. METHODS: We conducted a multicenter, randomized, controlled trial involving patients with ischemic cardiomyopathy and an ICD who had ventricular tachycardia despite the use of antiarrhythmic drugs. Patients were randomly assigned to receive either catheter ablation (ablation group) with continuation of baseline antiarrhythmic medications or escalated antiarrhythmic drug therapy (escalated-therapy group). In the escalated-therapy group, amiodarone was initiated if another agent had been used previously. The dose of amiodarone was increased if it had been less than 300 mg per day or mexiletine was added if the dose was already at least 300 mg per day. The primary outcome was a composite of death, three or more documented episodes of ventricular tachycardia within 24 hours (ventricular tachycardia storm), or appropriate ICD shock. RESULTS: Of the 259 patients who were enrolled, 132 were assigned to the ablation group and 127 to the escalated-therapy group. During a mean (±SD) of 27.9±17.1 months of follow-up, the primary outcome occurred in 59.1% of patients in the ablation group and 68.5% of those in the escalated-therapy group (hazard ratio in the ablation group, 0.72; 95% confidence interval, 0.53 to 0.98; P=0.04). There was no significant between-group difference in mortality. There were two cardiac perforations and three cases of major bleeding in the ablation group and two deaths from pulmonary toxic effects and one from hepatic dysfunction in the escalated-therapy group. CONCLUSIONS: In patients with ischemic cardiomyopathy and an ICD who had ventricular tachycardia despite antiarrhythmic drug therapy, there was a significantly lower rate of the composite primary outcome of death, ventricular tachycardia storm, or appropriate ICD shock among patients undergoing catheter ablation than among those receiving an escalation in antiarrhythmic drug therapy. (Funded by the Canadian Institutes of Health Research and others; VANISH ClinicalTrials.gov number, NCT00905853.).


Asunto(s)
Amiodarona/administración & dosificación , Antiarrítmicos/administración & dosificación , Cardiomiopatías/complicaciones , Ablación por Catéter , Taquicardia Ventricular/terapia , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Cardiomiopatías/mortalidad , Ablación por Catéter/efectos adversos , Desfibriladores Implantables , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Recurrencia , Prevención Secundaria , Taquicardia Ventricular/tratamiento farmacológico
6.
J Cardiovasc Electrophysiol ; 30(12): 2877-2884, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31646695

RESUMEN

BACKGROUND: Contemporary implantable cardioverter-defibrillator (ICD) programming involving delayed high-rate detection and use of supraventricular tachycardia (SVT) discriminators has significantly reduced the rate of inappropriate shocks. The extent to which SVT algorithms alone reduce inappropriate therapies is poorly understood. METHODS AND RESULTS: PainFree SST enrolled 2770 patients with a single- or dual-chamber ICD or cardiac resynchronization defibrillator. Patients were followed for 22 ± 9 months with SVT discriminators on in 96% of patients. Sustained ventricular tachyarrhythmias and SVT episodes were adjudicated by an independent physician committee. For this analysis, all episodes were subjected to postprocessing computer simulation with SVT discriminators off with and without delayed high-rate detection criteria (ventricular fibrillation zone only, 30/40 at 320 ms). There were 3282 adjudicated SVT episodes of which 115 resulted in an ICD shock and 113 received only ATP (2-year inappropriate shock and therapy rates of 3.1% and 4.1%). Therapy was appropriately withheld for the remaining 3054 SVT episodes. With both SVT discriminators and delayed high-rate detection simulated off, the 2-year inappropriate therapy rate would have been 22.9% (hazard ratio [HR] = 6.24; 95% confidence interval [CI]: 5.20-7.49). With SVT discriminators simulated off and delayed high-rate detection simulated on in all patients, the 2-year rate would have been 6.4% (HR = 1.63; CI: 1.44-1.85). CONCLUSIONS: The use of SVT discriminators has a significant role in reducing the rate of inappropriate ICD therapy even in the setting of delayed high-rate detection settings. Deactivating SVT discriminators would have resulted in an overall increase in the inappropriate ICD therapy rate by 63% and 524% with and without delayed high-rate detection programming, respectively.


Asunto(s)
Algoritmos , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Falla de Prótesis , Procesamiento de Señales Asistido por Computador , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Taquicardia Supraventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología
7.
Europace ; 21(8): 1176-1184, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31071213

RESUMEN

AIMS: Ablation of persistent atrial fibrillation (PsAF) has been performed by many techniques with varying success rates. This may be due to ablation techniques, patient demographics, comorbidities, and trial design. We conducted a meta-regression of studies of PsAF ablation to elucidate the factors affecting atrial fibrillation (AF) recurrence. METHODS AND RESULTS: Databases were searched for prospective studies of PsAF ablation. A meta-regression was performed. Fifty-eight studies (6767 patients) were included. Complex fractionated atrial electrogram (CFAE) ablation reduced freedom from AF by 8.9% [95% confidence interval (CI) -15 to -2.3, P = 0.009). Left atrial appendage [LAA isolation (three study arms)] increased freedom from AF by 39.5% (95% CI 9.1-78.4, P = 0.008). Posterior wall isolation (PWI) (eight study arms) increased freedom from AF by 19.4% (95% CI 3.3-38.1, P = 0.017). Linear ablation or ganglionated plexi ablation resulted in no significant effect on freedom from AF. More extensive ablation increased intraprocedural AF termination; however, intraprocedural AF termination was not associated with improved outcomes. Increased left atrial diameter was associated with a reduction in freedom from AF by 4% (95% CI -6.8% to -1.1%, P = 0.007) for every 1 mm increase in diameter. CONCLUSION: Linear ablation, PWI, and CFAE ablation improves intraprocedural AF termination, but such termination does not predict better long-term outcomes. Study arms including PWI or LAA isolation in the lesion set were associated with improved outcomes in terms of freedom from AF; however, further randomized trials are required before these can be routinely recommended. Left atrial size is the most important marker of AF chronicity influencing outcomes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/métodos , Efectos Adversos a Largo Plazo/epidemiología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Recurrencia , Análisis de Regresión , Medición de Riesgo/métodos , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 42(2): 132-138, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30478983

RESUMEN

BACKGROUND: Atrial arrhythmias are associated with major adverse cardiovascular events. Recent reports among implantable cardioverter defibrillator (ICD) patients have demonstrated a high prevalence of atrial fibrillation (AF), predominantly in dual-chamber recipients. AF incidence among patients with single-chamber systems (approximately 50% of all ICDs) is currently unknown. The objective was to estimate the prevalence of new-onset AF among single-chamber ICD patients by observing the rates of new atrial tachycardia (AT)/AF among a propensity scoring matched cohort of dual-chamber ICD patients from the PainFree SmartShock technology study, to better inform screening initiatives. METHODS: Among 2770 patients enrolled, 1862 single-chamber, dual-chamber, and cardiac resynchronization therapy subjects with no prior history of atrial tachyarrhythmias were included. Daily AT/AF burden was estimated using a propensity score weighted model against data from dual-chamber ICDs. RESULTS: Over 22 ± 9 months of follow-up, the estimated incidence of AT/AF-lasting at least 6 min, 6 h, and 24 h per day -in the single-chamber cohort was 22.0, 9.8, and 6.3%, whereas among dual-chamber patients, the prevalence was 26.6, 13.1, and 7.1%, respectively. Initiation of oral anticoagulation was estimated to occur in 9.8% of the propensity matched single-chamber cohort, which was higher than the actual observed rate of 6.0%. Stroke and transient ischemic attack occurred at low rates in all device subgroups. CONCLUSIONS: Atrial arrhythmias occur frequently, and significant underutilization of anticoagulation is suggested in single-chamber ICD recipients. Routine screening for AF should be considered among single-chamber ICD recipients.


Asunto(s)
Fibrilación Atrial/epidemiología , Desfibriladores Implantables , Complicaciones Posoperatorias/epidemiología , Anciano , Estudios de Cohortes , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Diseño de Prótesis
9.
J Cardiovasc Electrophysiol ; 29(11): 1471-1479, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30230101

RESUMEN

OBJECTIVE: We tested whether ablation methodology and study design can explain the varying outcomes in terms of atrial fibrillation (AF)-free survival at 1 year. BACKGROUND: There have been numerous paroxysmal AF ablation trials, which are heterogeneous in their use of different ablation techniques and study design. A useful approach to understanding how these factors influence outcome is to dismantle the trials into individual arms and reconstitute them as a large meta-regression. METHODS: Data were collected from 66 studies (6941 patients). With freedom from AF as the dependent variable, we performed meta-regression using the individual study arm as the unit. RESULTS: Success rates did not change regardless of the technique used to produce pulmonary vein isolation (PVI). Neither was adjunctive lesion sets associated with any improvement in outcome. Studies that included more males and fewer hypertensive patients were found more likely to report better outcomes. The electrocardiography method selected to assess outcome also plays an important role. Outcomes were worse in studies that used regular telemonitoring (by 23%; P < 0.001) or in patients who had implantable loop recorders (by 21%; P = 0.006), rather than those with the less thorough periodic Holter monitoring. CONCLUSIONS: Outcomes of AF ablation studies involving PVI are not affected by the technologies used to produce PVI. Neither do adjunctive lesion sets change the outcome. Achieving high success rates in these studies appears to be dependent more on patient mix and on the thoroughness of AF detection protocols. These should be carefully considered when quoting the success rates of AF ablation procedures that are derived from such studies.


Asunto(s)
Técnicas de Ablación/métodos , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos , Técnicas de Ablación/tendencias , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Ablación por Catéter/tendencias , Humanos , Selección de Paciente , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
10.
J Cardiovasc Electrophysiol ; 29(4): 603-608, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29356207

RESUMEN

INTRODUCTION: In patients with ischemic heart disease and ventricular tachycardia (VT) refractory to high dose amiodarone, the two most common therapeutic options are adjunctive mexiletine therapy or catheter ablation. There are little existing data on the efficacy of these strategies. We examined the relative efficacy of adjunctive mexiletine and catheter ablation among patients enrolled in the VANISH trial. METHODS: All subjects enrolled in the VANISH trial who had VT refractory to high dose (≥ 300 mg daily) amiodarone at baseline were included. Per protocol, subjects randomized to escalated drug therapy received adjunctive mexiletine. RESULTS: Nineteen of the 259 patients were receiving high-dose amiodarone at baseline and 11 were randomized to escalated therapy with mexiletine and 8 to ablation. The adjunctive mexiletine group had a higher rate of the primary composite outcome (death, VT storm, or appropriate shock) in comparison to catheter ablation (HR 6.87 [2.08-22.8]). Over 90% of the patients in the adjunctive mexiletine/group experienced a primary endpoint during a median 9.2 months' follow-up. There was no difference in the rate of adverse events between the two groups. CONCLUSIONS: Mexiletine has limited efficacy in the treatment of recurrent VT despite high-dose amiodarone therapy, in patients with ischemic heart disease. Catheter ablation is a superior strategy in this population.


Asunto(s)
Amiodarona/administración & dosificación , Antiarrítmicos/administración & dosificación , Ablación por Catéter , Sustitución de Medicamentos , Frecuencia Cardíaca/efectos de los fármacos , Mexiletine/administración & dosificación , Isquemia Miocárdica/complicaciones , Taquicardia Ventricular/cirugía , Potenciales de Acción/efectos de los fármacos , Anciano , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Mexiletine/efectos adversos , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Insuficiencia del Tratamiento
11.
Pacing Clin Electrophysiol ; 41(9): 1185-1191, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29928759

RESUMEN

BACKGROUND: The PainFree Smart Shock Technology (SST) study showed a low implantable cardioverter-defibrillator (ICD) inappropriate shock rate. However, the majority of patients were from Western countries with patient characteristics different from those in Japan. ICD shock rates using the novel SST algorithms in Japanese patients are still unknown. METHODS: All 2,770 patients in the PainFree SST study (Japan [JPN]: N = 181, other geographies [OJPN]: N = 2,589) were included in this analysis. RESULTS: Japanese patients had higher average left ventricular ejection fraction (P < 0.0001), higher prevalence of secondary prevention indications (P < 0.0001), nonischemic cardiomyopathy (P < 0.0001), and permanent atrial fibrillation (P < 0.0001). The appropriate shock rate at 12 months was not different between JPN and OJPN: 6.4% and 6.3%, respectively (P = 0.95). The inappropriate shock rate at 12 months was significantly higher in Japanese patients (2.9% vs 1.7%, P = 0.017). However, after propensity score matching to adjust for the difference in baseline characteristics, the difference in inappropriate shock rate was not statistically significant (P = 0.51). CONCLUSIONS: There was no difference in the appropriate shock rate between Japan and other geographies. The inappropriate shock rate in Japan was low, although it was slightly higher compared to other geographies due to baseline characteristics, including a higher prevalence of permanent AF. There was not a statistically significant difference after adjusting for baseline characteristics.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica , Anciano , Algoritmos , Desfibriladores Implantables , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Puntaje de Propensión , Estudios Prospectivos
12.
Europace ; 19(12): 1973-1980, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28340005

RESUMEN

AIMS: Single-chamber (VR-ICD) and subcutaneous (S-ICD) implantable cardioverter-defibrillators are effective to protect patients against sudden death but expose them to higher risk of inappropriate shock (IS). We sought to quantify the annual rate and influencing factors of ISs in VR- and S-ICDs from the literature. METHODS AND RESULTS: PubMed, Embase, and Cochrane Library were searched for full text articles with IS rates. Poisson distribution estimated proportion of patients with ISs; rates were annualized based on follow-up duration. Random effects meta-analysis accounted for study-to-study variation. Out of 3264 articles, 16 qualified for the meta-analysis. Across studies, 6.4% [95% confidence interval (CI) 5.1-7.9%] of patients received an IS per year. Meta-regression analyses demonstrated that IS rates were lower in more recent studies [rate ratio (RR) per year: 0.93, 95% CI: 0.87-0.98; P = 0.01] and trended lower in studies with longer follow-up (RR per year: 0.78, 95% CI: 0.60-1.01; P = 0.06). Use of S-ICDs (RR: 1.81, 95% CI: 0.86-3.81; P = 0.12) and ventricular tachycardia zone programmed on (RR: 1.13, 95% CI: 0.65-1.97; P = 0.66) were not associated with a significantly increased change in risk. The IS rate observed in one of the more recent studies was significantly lower than predicted after accounting for covariates (RR: 0.29, 95% CI: 0.14-0.60; P < 0.001). CONCLUSIONS: A comprehensive review of the literature shows that 6.4% of patients with ICDs experienced their first IS annually. One of the 16 studies was better than predicted with the lowest reported rate (1.9%) and could not be explained by timing of the study or other covariates.


Asunto(s)
Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Falla de Prótesis , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/mortalidad , Estimulación Eléctrica , Humanos , Oportunidad Relativa , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
JAMA ; 311(7): 692-700, 2014 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-24549549

RESUMEN

IMPORTANCE: Atrial fibrillation (AF) is the most common rhythm disorder seen in clinical practice. Antiarrhythmic drugs are effective for reduction of recurrence in patients with symptomatic paroxysmal AF. Radiofrequency ablation is an accepted therapy in patients for whom antiarrhythmic drugs have failed; however, its role as a first-line therapy needs further investigation. OBJECTIVE: To compare radiofrequency ablation with antiarrhythmic drugs (standard therapy) in treating patients with paroxysmal AF as a first-line therapy. DESIGN, SETTING, AND PATIENTS: A randomized clinical trial involving 127 treatment-naive patients with paroxysmal AF were randomized at 16 centers in Europe and North America to received either antiarrhythmic therapy or ablation. The first patient was enrolled July 27, 2006; the last patient, January 29, 2010. The last follow-up was February 16, 2012. INTERVENTIONS: Sixty-one patients in the antiarrhythmic drug group and 66 in the radiofrequency ablation group were followed up for 24 months. MAIN OUTCOMES AND MEASURES: The time to the first documented atrial tachyarrhythmia of more than 30 seconds (symptomatic or asymptomatic AF, atrial flutter, or atrial tachycardia), detected by either scheduled or unscheduled electrocardiogram, Holter, transtelephonic monitor, or rhythm strip, was the primary outcome. Secondary outcomes included symptomatic recurrences of atrial tachyarrhythmias and quality of life measures assessed by the EQ-5D tool. RESULTS: Forty-four patients (72.1%) in the antiarrhythmic group and in 36 patients (54.5%) in the ablation group experienced the primary efficacy outcome (hazard ratio [HR], 0.56 [95% CI, 0.35-0.90]; P = .02). For the secondary outcomes, 59% in the drug group and 47% in the ablation group experienced the first recurrence of symptomatic AF, atrial flutter, atrial tachycardia (HR, 0.56 [95% CI, 0.33-0.95]; P = .03). No deaths or strokes were reported in either group; 4 cases of cardiac tamponade were reported in the ablation group. In the standard treatment group, 26 patients (43%) underwent ablation after 1-year. Quality of life was moderately impaired at baseline in both groups and improved at the 1 year follow-up. However, improvement was not significantly different among groups. CONCLUSIONS AND RELEVANCE: Among patients with paroxysmal AF without previous antiarrhythmic drug treatment, radiofrequency ablation compared with antiarrhythmic drugs resulted in a lower rate of recurrent atrial tachyarrhythmias at 2 years. However, recurrence was frequent in both groups. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00392054.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Adulto , Anciano , Aleteo Atrial/terapia , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Taquicardia/terapia , Resultado del Tratamiento
14.
Heart Rhythm ; 21(6): 762-770, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38336190

RESUMEN

BACKGROUND: Sex-specific outcomes after catheter ablation (CA) for atrial fibrillation (AF) have reported conflicting findings. OBJECTIVE: We examined the impact of female sex on outcomes in patients with persistent AF (PsAF) from the Catheter Ablation for Persistent Atrial Fibrillation: A Multicentre Randomized Trial of Pulmonary Vein Isolation vs PVI with Posterior Left Atrial Wall Isolation (CAPLA) randomized trial. METHODS: A total of 338 patients with PsAF were randomized to pulmonary vein isolation (PVI) or PVI with posterior wall isolation (PWI). The primary outcome was arrhythmia recurrence at 12 months. Clinical and electroanatomical characteristics, arrhythmia recurrence, and quality of life were compared between women and men. RESULTS: Seventy-nine women (23.4%; PVI 37; PVI + PWI 42) and 259 men (76.6%; PVI 131; PVI + PWI 128) underwent AF ablation. Women were older {median age 70.4 (interquartile range [IQR] 64.8-74.6) years vs 64.0 (IQR 56.7-69.7) years; P < .001} and had more advanced left atrial electroanatomical remodeling. At 12 months, arrhythmia-free survival was lower in women (44.3% vs 56.8% in men; hazard ratio 1.44; 95% confidence interval 1.02-2.04; log-rank, P = .036). PWI did not improve arrhythmia-free survival at 12 months (hazard ratio 1.02; 95% confidence interval 0.74-1.40; log-rank, P = .711). The median AF burden was 0% in both groups (women: IQR 0.0%-2.2% vs men: IQR 0.0%-2.8%; P = .804). Health care utilization was comparable between women (36.7%) and men (30.1%) (P = .241); however, women were more likely to undergo a repeat procedure (17.7% vs 6.9%; P = .007). Women reported more severe baseline anxiety (average Hospital Anxiety and Depression Scale [HADS] anxiety score 7.5 ± 4.9 vs 6.3 ± 4.3 in men; P = .035) and AF-related symptoms (baseline Atrial Fibrillation Effect on Quality-of-Life Questionnaire [AFEQT] score 46.7 ± 20.7 vs 55.9 ± 23.0 in men; P = .002), with comparable improvements in psychological symptoms (change in HADS anxiety score -3.8 ± 4.6 vs -3.0 ± 4.5; P = .152 (change in HADS depression score -2.9 ± 5.0 vs -2.6 ± 4.0; P = .542) and greater improvement in AFEQT score compared with men at 12 months (change in AFEQT score +45.9 ± 23.1 vs +39.2 ± 24.8; P = .048). CONCLUSION: Women undergoing CA for PsAF report more significant symptoms and poorer quality of life at baseline than men. Despite higher arrhythmia recurrence and repeat procedures in women, the AF burden was comparably low, resulting in significant improvements in quality of life and psychological well-being after CA in both sexes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Calidad de Vida , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Factores Sexuales , Venas Pulmonares/cirugía , Resultado del Tratamiento , Recurrencia , Atrios Cardíacos/fisiopatología , Estudios de Seguimiento
15.
Pacing Clin Electrophysiol ; 36(1): e23-6, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21410725

RESUMEN

Change of the retrograde atrial activation sequence during radiofrequency (RF) ablation of left-side accessory pathway can be due to another accessory pathway, another mechanism for the tachycardia, or due to intraatrial conduction block, partial or complete, caused by RF delivery to a site proximal to the site of insertion of the accessory pathway. In this case report, a temporary complete intraatrial conduction block was created by RF delivery proximal to the site of accessory pathway insertion, causing a change in the retrograde atrial activation sequence during ongoing tachycardia that was terminated by ablation at the insertion site of accessory pathway.


Asunto(s)
Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Fibrilación Atrial/diagnóstico , Diagnóstico Diferencial , Humanos , Masculino , Taquicardia Supraventricular/complicaciones , Resultado del Tratamiento , Adulto Joven
16.
JACC Clin Electrophysiol ; 9(6): 808-821, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37380314

RESUMEN

BACKGROUND: Catheter ablation improves ventricular tachycardia (VT) event-free (time to event) survival in patients with antiarrhythmic drug (AAD)-refractory VT and previous myocardial infarction (MI). The effects of ablation on recurrent VT and implantable cardioverter-defibrillator (ICD) therapy (burden) have yet to be investigated. OBJECTIVES: This study sought to compare the VT and ICD therapy burden following treatment with either ablation or escalated AAD therapy among patients with VT and previous MI in the VANISH (Ventricular tachycardia AblatioN versus escalated antiarrhythmic drug therapy in ISchemic Heart disease) trial. METHODS: The VANISH trial randomized patients with previous MI and VT despite initial AAD therapy to either escalated AAD treatment or catheter ablation. VT burden was defined as the total number of VT events treated with ≥1 appropriate ICD therapy. Appropriate ICD therapy burden was defined as the total number of appropriate shocks or antitachycardia pacing therapies (ATPs) delivered. The Anderson-Gill recurrent event model was used to compare burden between the treatment arms. RESULTS: Of the 259 enrolled patients (median age, 69.8 years; 7.0% women), 132 patients were randomized to ablation and 129 patients were randomized to escalated AAD therapy. Over 23.4 months of follow-up, ablation-treated patients had a 40% lower shock-treated VT event burden and a 39% lower appropriate shock burden compared with patients who received escalated AAD therapy (P <0.05 for all). A reduction in VT burden, ATP-treated VT event burden, and appropriate ATP burden among ablation patients was only demonstrated in the stratum of patients with amiodarone-refractory VT (P <0.05 for all). CONCLUSIONS: Among patients with AAD-refractory VT and a previous MI, catheter ablation reduced shock-treated VT event burden and appropriate shock burden compared with escalated AAD therapy. There was also lower VT burden, ATP-treated VT event burden, and appropriate ATP burden among ablation-treated patients; however, the effect was limited to patients with amiodarone-refractory VT.


Asunto(s)
Amiodarona , Ablación por Catéter , Desfibriladores Implantables , Infarto del Miocardio , Taquicardia Ventricular , Humanos , Femenino , Anciano , Masculino , Antiarrítmicos/uso terapéutico , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/cirugía , Adenosina Trifosfato
17.
Heart Rhythm ; 20(2): 190-197, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36272710

RESUMEN

BACKGROUND: Antitachycardia pacing (ATP) is an established implantable cardioverter-defibrillator (ICD) therapy that terminates ventricular tachycardias (VTs) without painful ICD shocks. However, factors influencing ATP success are not well understood. OBJECTIVE: The purpose of this study was to examine ATP success rates by patient, device, and programming characteristics. METHODS: This retrospective analysis of the PainFree SmartShock Technology study included spontaneous ATP-treated monomorphic VT episodes. ATP success rates were calculated for various factors. Also, the relationship of ATP programming on shock burden and syncope were investigated. RESULTS: Of the 2770 enrolled patients (2200 [79%] male; mean age 65 years), 1699 (61%) received an ICD and 1071 (39%) a cardiac resynchronization therapy - defibrillator. ATP had >80% rate of success for terminating VTs overall, with similar rates observed between ICD and cardiac resynchronization therapy - defibrillator devices (82.2% vs 80.3%, respectively; P = .81) as well as between primary and secondary prevention patients with ICDs (77.2% vs 83.9% respectively; P = .25). Arrhythmias with a median cycle length of ≥320 ms had a significantly higher ATP success rate (88.0%; 95% confidence interval 84.8%-90.6%). The cumulative percentage of ATP success increased from 71% at 1 ATP sequence delivered to 87% at ≥8 sequences delivered. Programming more ATP sequences was associated with lower shock burden (P = .0005). There was no evidence that more sequences were associated with higher rates of syncope (P = .16). CONCLUSION: Delivering more ATP sequences resulted in a higher overall success of terminating VTs, while programming more ATP was associated with decreased shock burden and no evidence of increased syncope or acceleration. This suggests that more ATP sequences should be programmed when possible, but confirmation in prospective studies will be necessary.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Masculino , Anciano , Femenino , Estudios Prospectivos , Estudios Retrospectivos , Síncope/terapia , Adenosina Trifosfato , Resultado del Tratamiento
18.
JAMA Cardiol ; 8(5): 475-483, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36947030

RESUMEN

Importance: Recurrent atrial fibrillation (AF) commonly occurs after catheter ablation and is associated with patient morbidity and health care costs. Objective: To evaluate the superiority of an augmented double wide-area circumferential ablation (WACA) compared with a standard single WACA in preventing recurrent atrial arrhythmias (AA) (atrial tachycardia, atrial flutter, or atrial fibrillation [AF]) in patients with paroxysmal AF. Design, Setting, and Participants: This was a pragmatic, multicenter, prospective, randomized, open, blinded end point superiority clinical trial conducted at 10 university-affiliated centers in Canada. The trial enrolled patients 18 years and older with symptomatic paroxysmal AF from March 2015 to May 2017. Analysis took place between January and April 2022. Analyses were intention to treat. Interventions: Patients were randomized (1:1) to receive radiofrequency catheter ablation for pulmonary vein isolation with either a standard single WACA or an augmented double WACA. Main Outcomes and Measures: The primary outcome was AA recurrence between 91 and 365 days postablation. Patients underwent 42 days of ambulatory electrocardiography monitoring after ablation. Secondary outcomes included need for repeated catheter ablation and procedural and safety variables. Results: Of 398 patients, 195 were randomized to the single WACA (control) arm (mean [SD] age, 60.6 [9.3] years; 65 [33.3%] female) and 203 to the double WACA (experimental) arm (mean [SD] age, 61.5 [9.3] years; 66 [32.5%] female). Overall, 52 patients (26.7%) in the single WACA arm and 50 patients (24.6%) in the double WACA arm had recurrent AA at 1 year (relative risk, 0.92; 95% CI, 0.66-1.29; P = .64). Twenty patients (10.3%) in the single WACA arm and 15 patients (7.4%) in the double WACA arm underwent repeated catheter ablation (relative risk, 0.72; 95% CI, 0.38-1.36). Adjudicated serious adverse events occurred in 13 patients (6.7%) in the single WACA arm and 14 patients (6.9%) in the double WACA arm. Conclusions and Relevance: In this randomized clinical trial of patients with paroxysmal AF, additional ablation by performing a double ablation lesion set did not result in improved freedom from recurrent AA compared with a standard single ablation set. Trial Registration: ClinicalTrials.gov Identifier: NCT02150902.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Masculino , Fibrilación Atrial/tratamiento farmacológico , Estudios Prospectivos , Venas Pulmonares/cirugía , Electrocardiografía Ambulatoria , Ablación por Catéter/efectos adversos
19.
Curr Opin Cardiol ; 27(1): 1-7, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22123603

RESUMEN

PURPOSE OF REVIEW: Randomized controlled trials have established that prophylactic implantable cardioverter defibrillator (ICD) therapy improves survival in patients with reduced left ventricular ejection fraction (LVEF). However, mortality reduction is not uniform across the implanted population and recent data have highlighted the importance of nonsudden cardiac death (non-SCD) risk in predicting benefit from ICD therapy. This review explores the importance of non-SCD risk in patient selection for prophylactic ICD therapy, as well as the proposed approaches to identify potential ICD recipients at high risk of non-SCD. RECENT FINDINGS: Data from randomized controlled trials have demonstrated that patients at high risk of non-SCD do not gain significant survival benefit from prophylactic ICD therapy irrespective of their risk of SCD. A variety of strategies to identify low LVEF patients at high risk of non-SCD have been proposed. These include the use of individual risk markers, such as advanced age and renal dysfunction, the presence of cardiac and noncardiac comorbidities, and the use of more complex risk scores. SUMMARY: Non-SCD risk is an important issue in patient selection for prophylactic ICD therapy. However, the optimal strategy to identify patients at high non-SCD risk is unclear and further research is needed.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco/prevención & control , Volumen Sistólico , Factores de Edad , Gasto Cardíaco Bajo/complicaciones , Comorbilidad , Paro Cardíaco/etiología , Paro Cardíaco/mortalidad , Humanos , Guías de Práctica Clínica como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Insuficiencia Renal Crónica/mortalidad , Medición de Riesgo , Incertidumbre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA