Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 17(5): 60-75, 2016 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-27685119

RESUMEN

Particle therapy (PT) has shown positive therapeutic results in local control of locally advanced pancreatic lesions. PT effectiveness is highly influenced by target localization accuracy both in space, since the pancreas is located in proximity to radiosensitive vital organs, and in time as it is subject to substantial breathing-related motion. The purpose of this preliminary study was to quantify pancreas range of motion under typical PT treatment conditions. Three common immobilization devices (vacuum cushion, thermoplastic mask, and compressor belt) were evaluated on five male patients in prone and supine positions. Retrospective four-dimensional magnetic resonance imaging data were reconstructed for each condition and the pancreas was manually segmented on each of six breathing phases. A k-means algorithm was then applied on the manually segmented map in order to obtain clusters representative of the three pancreas segments: head, body, and tail. Centers of mass (COM) for the pancreas and its segments were computed, as well as their displacements with respect to a reference breathing phase (beginning exhalation). The median three-dimensional COM displacements were in the range of 3 mm. Latero-lateral and superior-inferior directions had a higher range of motion than the anterior-posterior direction. Motion analysis of the pancreas segments showed slightly lower COM displacements for the head cluster compared to the tail cluster, especially in prone position. Statistically significant differences were found within patients among the investigated setups. Hence a patient-specific approach, rather than a general strategy, is suggested to define the optimal treatment setup in the frame of a millimeter positioning accuracy.


Asunto(s)
Inmovilización/instrumentación , Imagen por Resonancia Magnética/métodos , Neoplasias Pancreáticas/radioterapia , Posicionamiento del Paciente , Errores de Configuración en Radioterapia/prevención & control , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Respiración , Estudios Retrospectivos
2.
Radiol Med ; 119(4): 277-82, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24337759

RESUMEN

PURPOSE: The Italian National Centre for Oncological Hadrontherapy (Centro Nazionale di Adroterapia Oncologica, CNAO), equipped with a proton and ion synchrotron, started clinical activity in September 2011. The clinical and technical characteristics of the first ten proton beam radiotherapy treatments are reported. MATERIALS AND METHODS: Ten patients, six males and four females (age range 27-73 years, median 55.5), were treated with proton beam radiotherapy. After one to two surgical procedures, seven patients received a histological diagnosis of chordoma (of the skull base in three cases, the cervical spine in one case and the sacrum in three cases) and three of low-grade chondrosarcoma (skull base). Prescribed doses were 74 GyE for chordoma and 70 GyE for chondrosarcoma at 2 GyE/fraction delivered 5 days per week. RESULTS: Treatment was well tolerated without toxicity-related interruptions. The maximal acute toxicity was grade 2, with oropharyngeal mucositis, nausea and vomiting for the skull base tumours, and grade 2 dermatitis for the sacral tumours. After 6-12 months of follow-up, no patient developed tumour progression. CONCLUSIONS: The analysis of the first ten patients treated with proton therapy at CNAO showed that this treatment was feasible and safe. Currently, patient accrual into these as well as other approved protocols is continuing, and a longer follow-up period is needed to assess tumour control and late toxicity.


Asunto(s)
Condrosarcoma/radioterapia , Cordoma/radioterapia , Neoplasias de la Base del Cráneo/radioterapia , Neoplasias de la Columna Vertebral/radioterapia , Adulto , Anciano , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Italia , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Protones , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia Asistida por Computador , Sincrotrones , Tomografía Computarizada por Rayos X
3.
J Appl Clin Med Phys ; 14(4): 4087, 2013 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-23835375

RESUMEN

The purpose of this work was to evaluate the intrapatient tumor position reproducibility in a deep inspiration breath-hold (DIBH) technique based on two infrared optical tracking systems, ExacTrac and ELITETM, in stereotactic treatment of lung and liver lesions. After a feasibility study, the technique was applied to 15 patients. Each patient, provided with a real-time visual feedback of external optical marker displacements, underwent a full DIBH, a free-breathing (FB), and three consecutive DIBH CT-scans centered on the lesion to evaluate the tumor position reproducibility. The mean reproducibility of tumor position during repeated DIBH was 0.5 ± 0.3 mm in laterolateral (LL), 1.0 ± 0.9 mm in anteroposterior (AP), and 1.4 ± 0.9 mm in craniocaudal (CC) direction for lung lesions, and 1.0 ± 0.6 mm in LL, 1.1 ± 0.5 mm in AP, and 1.2 ± 0.4 mm in CC direction for liver lesions. Intra- and interbreath-hold reproducibility during treatment, as determined by optical markers displacements, was below 1 mm and 3 mm, respectively, in all directions for all patients. Optically-guided DIBH technique provides a simple noninvasive method to minimize breathing motion for collaborative patients. For each patient, it is important to ensure that the tumor position is reproducible with respect to the external markers configuration.


Asunto(s)
Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Radioterapia Conformacional/métodos , Adulto , Anciano , Contencion de la Respiración , Sistemas de Computación , Retroalimentación Sensorial , Femenino , Humanos , Rayos Infrarrojos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Movimiento , Dispositivos Ópticos , Posicionamiento del Paciente/instrumentación , Posicionamiento del Paciente/métodos , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados , Respiración , Tomografía Computarizada por Rayos X
4.
Br J Radiol ; 93(1107): 20190595, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31687833

RESUMEN

OBJECTIVE: Accurate patient positioning is crucial in particle therapy due to the geometrical selectivity of particles. We report and discuss the National Center for Oncological Hadrontherapy (CNAO) experience in positioning accuracy and stability achieved with solid thermoplastic masks fixed on index base plates and assessed by daily orthogonal X-ray imaging. METHODS: Positioning data were retrospectively collected (between 2012 and 2018) and grouped according to the treated anatomical site. 19696 fractions of 1325 patients were evaluated.The study was designed to assess:(i) the number of fractions in which a single correction vector was applied(SCV);(ii) the number of fractions in which further setup verification was performed (SV);(iii) the number of fractions in which SV lead to an additional correction within (MCV<5min) or after (MCV>5min) 5 minutes from the first setup correction;(iv) the systematic (Σ) and random (σ) error components of the correction vectors applied. RESULTS: A SCV was applied in 71.5% of fractions, otherwise SV was required. In 30.6% of fractions with SV, patient position was not further revised. In the remaining fractions, MCV<5min and MCV>5min were applied mainly in extracranial and cranial sites respectively.Interfraction Σ was ≤ 1.7 mm/0.7° and σ was ≤ 1.2 mm/0.6° in cranial sites while in extracranial sites Σ was ≤ 5.5 mm/0.9° and σ was ≤4.4 mm/0.9°. Setup residuals were submillimetric in all sites. In cranial patients, maximum intrafractional Σ was 0.8 mm/0.4°. CONCLUSION: This report extensively quantifies inter- and intrafraction setup accuracy on an institutional basis and confirms the need of image guidance to fully benefit from the geometrical selectivity of particles. ADVANCES IN KNOWLEDGE: The reported analysis provides a board institutional data set on the evaluation of patient immobilization and bony anatomy alignment for several particle therapy clinical indications.


Asunto(s)
Inmovilización/instrumentación , Máscaras , Neoplasias/radioterapia , Posicionamiento del Paciente/métodos , Errores de Configuración en Radioterapia/prevención & control , Instituciones Oncológicas , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Inmovilización/métodos , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Incertidumbre
5.
Phys Med ; 59: 55-63, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30928066

RESUMEN

PURPOSE: At Centro Nazionale di Adroterapia Oncologica (CNAO, Pavia, Italy) ocular proton therapy (OPT) is delivered using a non-dedicated beamline. This paper describes the novel clinical workflow as well as technologies and methods adopted to achieve accurate target positioning and verification during ocular proton therapy at CNAO. METHOD: The OPT clinical protocol at CNAO prescribes a treatment simulation and a delivery phase, performed in the CT and treatment rooms, respectively. The patient gaze direction is controlled and monitored during the entire workflow by means of an eye tracking system (ETS) featuring two optical cameras and an embedded fixation diode light. Thus, the accurate alignment of the fixation light provided to the patient to the prescribed gazed direction is required for an effective treatment. As such, a technological platform based on active robotic manipulators and IR optical tracking-based guidance was developed and tested. The effectiveness of patient positioning strategies was evaluated on a clinical dataset comprising twenty patients treated at CNAO. RESULTS: According to experimental testing, the developed technologies guarantee uncertainties lower than one degree in gaze direction definition by means of ETS-guided positioning. Patient positioning and monitoring strategies during treatment effectively mitigated set-up uncertainties and exhibited sub-millimetric accuracy in radiopaque markers alignment. CONCLUSION: Ocular proton therapy is currently delivered at CNAO with a non-dedicated beamline. The technologies developed for patient positioning and motion monitoring have proven to be compliant with the high geometrical accuracy required for the treatment of intraocular tumors.


Asunto(s)
Neoplasias del Ojo/radioterapia , Movimiento , Posicionamiento del Paciente/instrumentación , Terapia de Protones/instrumentación , Planificación de la Radioterapia Asistida por Computador/instrumentación , Neoplasias del Ojo/diagnóstico por imagen , Humanos , Sincrotrones , Tomografía Computarizada por Rayos X
6.
Technol Cancer Res Treat ; 7(3): 187-95, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18473490

RESUMEN

To quantify the advantages of a 6 degrees of freedom (dof) versus the conventional 3- or 4-dof correction modality for stereotactic body radiation therapy (SBRT) treatments. Eighty-five patients were fitted with 5-7 infra-red passive markers for optical localization. Data, acquired during the treatment, were analyzed retrospectively to simulate and evaluate the best approach for correcting patient misalignments. After the implementation of each correction, the new position of the target (tumor's center of mass) was estimated by means of a dedicated stereotactic algorithm. The Euclidean distance between the corrected and the planned location of target point was calculated and compared to the initial mismatching. Initial and after correction median+/-quartile displacements affecting external control points were 3.74+/-2.55 mm (initial), 2.45+/-0.91 mm (3-dof), 2.37+/-0.95 mm (4-dof), and 2.03+/-1.47 mm (6-dof). The benefit of a six-parameter adjustment was particularly evident when evaluating the results relative to the target position before and after the re-alignment. In this context, the Euclidean distance between the planned and the current target point turned to 0.82+/-1.12 mm (median+/-quartile values) after the roto-translation versus the initial displacement of 2.98+/-2.32 mm. No statistical improvements were found after 3- and 4-dof correction (2.73+/-1.22 mm and 2.60+/-1.31 mm, respectively). Angular errors were 0.09+/-0.93 degrees (mean+/-std). Pitch rotation in abdomen site showed the most relevant deviation, being -0.46+/-1.27 degrees with a peak value of 5.46 degrees . Translational misalignments were -0.68+/-2.60 mm (mean+/-std) with the maximum value of 12 mm along the cranio-caudal direction. We conclude that positioning system platforms featuring 6-dof are preferred for high precision radiation therapy. Data are in line with previous results relative to other sites and represent a relevant record in the framework of SBRT.


Asunto(s)
Neoplasias Abdominales/cirugía , Neoplasias Pulmonares/cirugía , Radiocirugia , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Tomografía Computarizada por Rayos X
7.
Int J Radiat Oncol Biol Phys ; 64(2): 635-42, 2006 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-16198068

RESUMEN

PURPOSE: To investigate size and frequency of interfractional patient setup variability in hypofractionated stereotactic extracranial radiotherapy. METHODS AND MATERIALS: Infrared optical 3D tracking of surface markers was applied to quantify setup variability on 51 patients. Isocenter position repeatability was assessed by means of frameless anatomic calibration and was compared with portal image evaluation. Specific data analysis allowed for compensation of patients' breathing movements and for separation of the effects of operator-dependent misalignments and respiration-induced displacements. Effects of patient position (supine vs. prone) and treatment table configuration were investigated. RESULTS: Patient positioning assisted by the optical tracking device allowed reducing displacements of surface control points within the 3-mm range. Errors in isocenter localization were in the range of a few millimeters. This was in agreement with the portal image evaluation. Breathing motion introduced appreciable errors, which increased control points and isocenter 3D variability. This effect was significantly higher than those related to other investigated factors. CONCLUSIONS: The role of infrared optical tracking devices for patient positioning is assessed on a large patient population. Their use in the frame of high-precision radiotherapy is emphasized by the application of related methodologies for breathing phase detection and frameless isocenter localization.


Asunto(s)
Neoplasias Abdominales/radioterapia , Neoplasias Pélvicas/radioterapia , Técnicas Estereotáxicas , Neoplasias Torácicas/radioterapia , Calibración , Fraccionamiento de la Dosis de Radiación , Humanos , Rayos Infrarrojos , Posición Prona , Reproducibilidad de los Resultados , Respiración , Posición Supina
8.
Radiother Oncol ; 79(2): 170-8, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16574263

RESUMEN

BACKGROUND AND PURPOSE: The aim of the study was to investigate the clinical application of a technique for patient set-up verification in breast cancer radiotherapy, based on the 3D localization of a hybrid configuration of surface control points. MATERIALS AND METHODS: An infrared optical tracker provided the 3D position of two passive markers and 10 laser spots placed around and within the irradiation field on nine patients. A fast iterative constrained minimization procedure was applied to detect and compensate patient set-up errors, through the control points registration with reference data coming from treatment plan (markers reference position, CT-based surface model). RESULTS: The application of the corrective spatial transformation estimated by the registration procedure led to significant improvement of patient set-up. Median value of 3D errors affecting three additional verification markers within the irradiation field decreased from 5.7 to 3.5 mm. Errors variability (25-75%) decreased from 3.2 to 2.1 mm. Laser spots registration on the reference surface model was documented to contribute substantially to set-up errors compensation. CONCLUSIONS: Patient set-up verification through a hybrid set of control points and constrained surface minimization algorithm was confirmed to be feasible in clinical practice and to provide valuable information for the improvement of the quality of patient set-up, with minimal requirement of operator-dependant procedures. The technique combines conveniently the advantages of passive markers based methods and surface registration techniques, by featuring immediate and robust estimation of the set-up accuracy from a redundant dataset.


Asunto(s)
Neoplasias de la Mama/radioterapia , Radioterapia Asistida por Computador , Femenino , Humanos , Rayos Infrarrojos , Rayos Láser , Postura
9.
Med Phys ; 33(4): 1141-52, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16696492

RESUMEN

In the field of extra-cranial radiotherapy, several inaccuracies can make the application of frameless stereotactic localization techniques error-prone. When optical tracking systems based on surface fiducials are used, inter- and intra-fractional uncertainties in marker three-dimensional (3D) detection may lead to inexact tumor position estimation, resulting in erroneous patient setup. This is due to the fact that external fiducials misdetection results in deformation effects that are poorly handled in a rigid-body approach. In this work, the performance of two frameless stereotactic localization algorithms for 3D tumor position reconstruction in extra-cranial radiotherapy has been specifically tested. Two strategies, unweighted versus weighted, for stereotactic tumor localization were examined by exploiting data coming from 46 patients treated for extra-cranial lesions. Measured isocenter displacements and rotations were combined to define isocentric procedures, featuring 6 degrees of freedom, for correcting patient alignment (isocentric positioning correction). The sensitivity of the algorithms to uncertainties in the 3D localization of fiducials was investigated by means of 184 numerical simulations. The performance of the implemented isocentric positioning correction was compared to conventional point-based registration. The isocentric positioning correction algorithm was tested on a clinical dataset of inter-fractional and intra-fractional setup errors, which was collected by means of an optical tracker on the same group of patients. The weighted strategy exhibited a lower sensitivity to fiducial localization errors in simulated misalignments than those of the unweighted strategy. Isocenter 3D displacements provided by the weighted strategy were consistently smaller than those featured by the unweighted strategy. The peak decrease in median and quartile values of isocenter 3D displacements were 1.4 and 2.7 mm, respectively. Concerning clinical data, the weighted strategy isocentric positioning correction provided the reduction of fiducial registration errors, featuring up to 61.7% decrease in median values (versus 46.8% for the unweighted strategy) of initial displacements. The weighted strategy proved high performance in minimizing the effects of fiducial localization errors, showing a great potential in improving patient setup. The clinical data analysis revealed that the application of a robust reconstruction algorithm may provide high-quality results in patient setup verification, by properly managing external fiducials localization errors.


Asunto(s)
Algoritmos , Imagenología Tridimensional/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiocirugia/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Tumori ; 101(3): 273-80, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25908027

RESUMEN

AIMS AND BACKGROUND: This study evaluates 3 different imaging modalities--ultrasound (US), stereoscopic X-ray imaging of implanted markers (Visicoils) (X-ray), and kV cone-beam computed tomography (CBCT)--to assess interfraction and intrafraction localization error during conformal radiation therapy of prostate cancer. METHODS AND STUDY DESIGN: The study population consisted of 186 consecutive prostate cancer patients treated with an image-guided radiotherapy (IGRT) hypofractionated protocol using 3 techniques: 32 with X-ray, 30 with CBCT, and 124 with US. Treatment dose of 70.2 Gy was delivered in 26 fractions with a conformal dynamic arcs technique. Interfraction prostate localization errors were determined for the 3 techniques. Moreover, interfraction and intrafraction prostate motion in terms of translations and rotations, as well as residual errors, were determined with X-ray. RESULTS: The systematic and random components of the prostate localization errors were as follows: (1) with X-ray 3.0 ± 3.4, 2.3 ± 2.7, 1.8 ± 2.3 mm in anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions and 1.8° ± 1.2°, 2.3° ± 1.5°, 2.7° ± 3.1°, for the yaw, roll, and pitch rotations; (2) with CBCT 3.5 ± 4.2, 3.3 ± 3.3, 2.5 ± 3.1 mm in AP, SI, and LR directions; (3) with US 3.7 ± 4.7, 3.4 ± 4.3, 2.3 ± 3.5 mm in AP, SI, and LR directions. Residual errors with X-ray were less than 1 mm in all directions. Intrafraction prostate motion of less than 0.5 mm in LR and of the order of 1 mm in AP and SI directions was found. This led to a significant reduction of the margins, potentially important for dose escalation studies. CONCLUSIONS: Daily on-line IGRT with stereoscopic X-ray imaging allowed a consistent PTV margin reduction considering residual interfraction prostate localization error and intrafraction motion. X-ray offers the best compromise among accuracy, reliability, dose to the patient, and time investment for daily IGRT treatment of prostate.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Fraccionamiento de la Dosis de Radiación , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen/métodos , Anciano , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Resultado del Tratamiento , Ultrasonografía Intervencional
11.
Med Phys ; 42(5): 2194-202, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25979013

RESUMEN

PURPOSE: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. METHODS: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. RESULTS: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. CONCLUSIONS: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring during ocular radiotherapy treatments. The device aims at improving state-of-the-art invasive procedures based on surgical implantation of radiopaque clips and repeated acquisition of X-ray images, with expected positive effects on treatment quality and patient outcome.


Asunto(s)
Medidas del Movimiento Ocular , Neoplasias del Ojo/radioterapia , Imagen Óptica/métodos , Radioterapia/métodos , Algoritmos , Calibración , Diseño de Equipo , Ojo/anatomía & histología , Ojo/patología , Medidas del Movimiento Ocular/instrumentación , Movimientos Oculares , Neoplasias del Ojo/patología , Neoplasias del Ojo/fisiopatología , Humanos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Rayos Infrarrojos , Imagen por Resonancia Magnética/métodos , Imagen Óptica/instrumentación , Fantasmas de Imagen , Radioterapia/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Grabación en Video/instrumentación , Grabación en Video/métodos
12.
J Radiat Res ; 54 Suppl 1: i129-35, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23824116

RESUMEN

The synergy between in-room imaging and optical tracking, in co-operation with highly accurate robotic patient handling represents a concept for patient-set-up which has been implemented at CNAO (Centro Nazionale di Adroterapia Oncologica). In-room imaging is based on a double oblique X-ray projection system; optical tracking consists of the detection of the position of spherical markers placed directly on the patient's skin or on the immobilization devices. These markers are used as external fiducials during patient positioning and dose delivery. This study reports the results of a comparative analysis between in-room imaging and optical tracking data for patient positioning within the framework of high-precision particle therapy. Differences between the optical tracking system (OTS) and the imaging system (IS) were on average within the expected localization accuracy. On the first 633 fractions for head and neck (H&N) set-up procedures, the corrections applied by the IS, after patient positioning using the OTS only, were for the mostly sub-millimetric regarding the translations (0.4 ± 1.1 mm) and sub-gradual regarding the rotations (0.0° ± 0.8°). On the first 236 fractions for pelvis localizations the amplitude of the corrections applied by the IS after preliminary optical set-up correction were moderately higher and more dispersed (translations: 1.3 ± 2.9 mm, rotations 0.1 ± 0.9°). Although the indication of the OTS cannot replace information provided by in-room imaging devices and 2D-3D image registration, the reported data show that OTS preliminary correction might greatly support image-based patient set-up refinement and also provide a secondary, independent verification system for patient positioning.


Asunto(s)
Terapia de Protones/instrumentación , Terapia de Protones/métodos , Radioterapia/instrumentación , Algoritmos , Condrosarcoma/radioterapia , Cordoma/radioterapia , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Dispositivos Ópticos , Radioterapia/métodos , Reproducibilidad de los Resultados , Robótica , Rayos X
13.
Tumori ; 99(2): e34-7, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23748826

RESUMEN

Proton beam radiotherapy, an innovative treatment modality, allows delivery of high radiation doses to the target while sparing surrounding healthy structures. The Centro Nazionale di Adroterapia Oncologica (CNAO), equipped with a synchrotron and capable of using both protons and ions, initiated its clinical activity in September 2011. The first treatment of a skull base tumor with protons is reported here. The case of a 26-year-old man with an intracranial low-grade chondrosarcoma of the right petroclival junction is discussed with emphasis on technical and clinical details. Two previous surgical interventions had achieved partial removal of the tumor and the patient was treated with protons for residual disease. The prescribed dose was 70 GyE in 35 fractions of 2 GyE. Treatment was completed with minimal acute toxicity consisting of grade 1 alopecia and nausea. Nine months after treatment the disease is locally controlled. Use of high-energy protons at CNAO is a safe and effective means of treating a tumor located near critical normal structures.


Asunto(s)
Condrosarcoma/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Terapia de Protones , Radioterapia Asistida por Computador/métodos , Neoplasias de la Base del Cráneo/radioterapia , Adulto , Alopecia/etiología , Condrosarcoma/complicaciones , Condrosarcoma/diagnóstico , Condrosarcoma/cirugía , Diplopía/etiología , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Náusea/etiología , Clasificación del Tumor , Recurrencia Local de Neoplasia/diagnóstico , Protones/efectos adversos , Planificación de la Radioterapia Asistida por Computador , Neoplasias de la Base del Cráneo/complicaciones , Neoplasias de la Base del Cráneo/diagnóstico , Neoplasias de la Base del Cráneo/cirugía , Sincrotrones , Tomografía Computarizada por Rayos X
14.
Int J Radiat Oncol Biol Phys ; 82(5): 1706-14, 2012 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-21605942

RESUMEN

PURPOSE: To compare infrared (IR) optical vs. stereoscopic X-ray technologies for patient setup in image-guided stereotactic radiotherapy. METHODS AND MATERIALS: Retrospective data analysis of 233 fractions in 127 patients treated with hypofractionated stereotactic radiotherapy was performed. Patient setup at the linear accelerator was carried out by means of combined IR optical localization and stereoscopic X-ray image fusion in 6 degrees of freedom (6D). Data were analyzed to evaluate the geometric and dosimetric discrepancy between the two patient setup strategies. RESULTS: Differences between IR optical localization and 6D X-ray image fusion parameters were on average within the expected localization accuracy, as limited by CT image resolution (3 mm). A disagreement between the two systems below 1 mm in all directions was measured in patients treated for cranial tumors. In extracranial sites, larger discrepancies and higher variability were observed as a function of the initial patient alignment. The compensation of IR-detected rotational errors resulted in a significantly improved agreement with 6D X-ray image fusion. On the basis of the bony anatomy registrations, the measured differences were found not to be sensitive to patient breathing. The related dosimetric analysis showed that IR-based patient setup caused limited variations in three cases, with 7% maximum dose reduction in the clinical target volume and no dose increase in organs at risk. CONCLUSIONS: In conclusion, patient setup driven by IR external surrogates localization in 6D featured comparable accuracy with respect to procedures based on stereoscopic X-ray imaging.


Asunto(s)
Neoplasias Encefálicas/cirugía , Posicionamiento del Paciente/métodos , Radiocirugia/métodos , Radioterapia Guiada por Imagen/métodos , Neoplasias Torácicas/cirugía , Neoplasias Abdominales , Puntos Anatómicos de Referencia/diagnóstico por imagen , Neoplasias Encefálicas/diagnóstico por imagen , Fraccionamiento de la Dosis de Radiación , Marcadores Fiduciales , Humanos , Rayos Infrarrojos , Órganos en Riesgo/efectos de la radiación , Traumatismos por Radiación/prevención & control , Estudios Retrospectivos , Neoplasias Torácicas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
15.
Radiat Oncol ; 6: 38, 2011 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-21496255

RESUMEN

BACKGROUND: The purpose of this study is to investigate intra-fraction setup variability in hypo-fractionated cranial and body radiotherapy; this is achieved by means of integrated infrared optical localization and stereoscopic kV X-ray imaging. METHOD AND MATERIALS: We analyzed data coming from 87 patients treated with hypo-fractionated radiotherapy at cranial and extra-cranial sites. Patient setup was realized through the ExacTrac X-ray 6D system (BrainLAB, Germany), consisting of 2 infrared TV cameras for external fiducial localization and X-ray imaging in double projection for image registration. Before irradiation, patients were pre-aligned relying on optical marker localization. Patient position was refined through the automatic matching of X-ray images to digitally reconstructed radiographs, providing 6 corrective parameters that were automatically applied using a robotic couch. Infrared patient localization and X-ray imaging were performed at the end of treatment, thus providing independent measures of intra-fraction motion. RESULTS: According to optical measurements, the size of intra-fraction motion was (median ± quartile) 0.3 ± 0.3 mm, 0.6 ± 0.6 mm, 0.7 ± 0.6 mm for cranial, abdominal and lung patients, respectively. X-ray image registration estimated larger intra-fraction motion, equal to 0.9 ± 0.8 mm, 1.3 ± 1.2 mm, 1.8 ± 2.2 mm, correspondingly. CONCLUSION: Optical tracking highlighted negligible intra-fraction motion at both cranial and extra-cranial sites. The larger motion detected by X-ray image registration showed significant inter-patient variability, in contrast to infrared optical tracking measurement. Infrared localization is put forward as the optimal strategy to monitor intra-fraction motion, featuring robustness, flexibility and less invasivity with respect to X-ray based techniques.


Asunto(s)
Neoplasias Abdominales/radioterapia , Neoplasias Encefálicas/radioterapia , Fraccionamiento de la Dosis de Radiación , Neoplasias Pulmonares/radioterapia , Humanos , Inmovilización , Rayos Infrarrojos , Movimiento , Posicionamiento del Paciente , Resultado del Tratamiento , Rayos X
16.
Urol Oncol ; 29(5): 523-32, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-20005749

RESUMEN

OBJECTIVES: To compare acute toxicity of prostate cancer image-guided hypofractionated radiotherapy (hypo-IGRT) with conventional fractionation without image-guidance (non-IGRT). To test the hypothesis that the potentially injurious effect of hypofractionation can be counterbalanced by the reduced irradiated normal tissue volume using IGRT approach. MATERIALS AND METHODS: One hundred seventy-nine cT1-T2N0M0 prostate cancer patients were treated within the prospective study with 70.2 Gy/26 fractions (equivalent to 84 Gy/42 fractions, α/ß 1.5 Gy) using IGRT (transabdominal ultrasound, ExacTrac X-Ray system, or cone-beam computer tomography). Their prospectively collected data were compared with data of 174 patients treated to 80 Gy/40 fractions with non-IGRT. The difference between hypo-IGRT and non-IGRT cohorts included fractionation (hypofractionation vs. conventional fractionation), margins (hypo-IGRT margins: 7 mm and 3 mm, for all but posterior margins; respectively; non-IGRT margins: 10 and 5 mm, for all but posterior margins, respectively), and use of image-guidance or not. Multivariate analysis was performed to define the tumor-, patient-, and treatment-related predictors for acute toxicity. RESULTS: All patients completed the prescribed radiotherapy course. Acute toxicity in the hypo-IGRT cohort included rectal (G1: 29.1%; G2: 11.2%; G3: 1.1%) and urinary events (G1: 33.5%; G2: 39.1%; G3: 5%). Acute toxicity in the non-IGRT patients included rectal (G1: 16.1%; G2: 6.3%) and urinary events (G1: 36.2%; G2: 20.7%; G3: 0.6%). In 1 hypo-IGRT and 2 non-IGRT patients, radiotherapy was temporarily interrupted due to acute toxicity. The incidence of mild (G1-2) rectal and bladder complications was significantly higher for hypo-IGRT (P = 0.0014 and P < 0.0001, respectively). Multivariate analysis showed that hypo-IGRT (P = 0.001) and higher PSA (P = 0.046) are correlated with higher acute urinary toxicity. No independent factor was identified for acute rectal toxicity. No significant impact of IGRT system on acute toxicity was observed. CONCLUSIONS: The acute toxicity rates were low and similar in both study groups with some increase in mild acute urinary injury in the hypo-IGRT patients (most probably due to the under-reporting in the retrospectively analyzed non-IGRT cohort). The higher incidence of acute bowel reactions observed in hypo-IGRT group was not significant in the multivariate analysis. Further investigation is warranted in order to exclude the bias due to the nonrandomized character of the study.


Asunto(s)
Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Traumatismos por Radiación/diagnóstico por imagen , Radioterapia Conformacional/efectos adversos , Anciano , Anciano de 80 o más Años , Fraccionamiento de la Dosis de Radiación , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Traumatismos por Radiación/etiología , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos , Tasa de Supervivencia , Tomografía Computarizada por Rayos X
17.
J Radiat Res ; 48 Suppl A: A61-74, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17513901

RESUMEN

In external beam radiotherapy, modern technologies for dynamic dose delivery and beam conformation provide high selectivity in radiation dose administration to the pathological volume. A comparable accuracy level is needed in the 3-D localization of tumor and organs at risk (OARs), in order to accomplish the planned dose distribution in the reality of each irradiation session. In-room imaging techniques for patient setup verification and tumor targeting may benefit of the combined daily use of optical tracking technologies, supported by techniques for the detection and compensation of organ motion events. Multiple solutions to enhance the use of optical tracking for the on-line correction of target localization uncertainties are described, with specific emphasis on the compensation of setup errors, breathing movements and non-rigid deformations. The final goal is the implementation of customized protocols where appropriate external landmarks, to be tracked in real-time by means of non-invasive optical devices, are selected as a function of inner target localization. The presented methodology features high accuracy in patient setup optimization, also providing a valuable tool for on-line patient surveillance, taking into account both breathing and deformation effects. The methodic application of optical tracking is put forward to represent a reliable and low cost procedure for the reduction of safety margins, once the patient-specific correlation between external landmarks and inner structures has been established. Therefore, the integration of optical tracking with in-room imaging devices is proposed as a way to gain higher confidence in the framework of Image Guided Radiation Therapy (IGRT) treatments.


Asunto(s)
Diagnóstico por Imagen , Radioterapia Guiada por Imagen , Humanos , Movimiento , Neoplasias/radioterapia , Órganos en Riesgo , Planificación de la Radioterapia Asistida por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA