RESUMEN
BACKGROUND: Single-lead electrocardiogram (ECG) devices may allow detection and diagnosis of cardiac rhythms. However, data on their accuracy for detecting cardiac arrhythmias beyond atrial fibrillation are limited. We aimed to determine the accuracy of the AliveCor KardiaMobile (AC) (AliveCor Inc, Mountain View, CA, USA) for the diagnosis of arrhythmias against gold standard cardiac electrophysiology study (EPS). METHOD: Patients undergoing clinically indicated EPS underwent simultaneous rhythm recording with an AC, standard 12-lead ECG, and EP catheters for intracardiac electrograms. Rhythms recorded during EPS were classified based on electrogram, 12-lead ECG, and clinical findings. Blinded reviewers provided differential diagnoses for the single-lead AC tracings; a separate reviewer compared diagnoses made between the AC tracings and EPS findings. RESULTS: In 49 patients, 843 cardiac rhythms were captured during 502 AC recordings. Analysis of tracings containing sinus rhythm (n=273) returned an overall accuracy of 92%, with sensitivity and specificity values of 93% and 92%, respectively. Accuracy for tracings per rhythm was atrial fibrillation 91% (n=51); supraventricular tachycardia accuracy was 89% (n=191), ventricular tachycardia 91% (n=198), ventricular fibrillation 98% (n=11), and asystole 100% (n=5). Accuracy for supraventricular ectopy was 93% (n=28) and for premature ventricular complexes was 91% (n=86). Overall accuracy was 94% for solitary rhythms and 93% in tracings from patients with baseline bundle branch block. CONCLUSIONS: When compared against the gold standard EPS diagnosis, the interpretation of arrhythmias recorded by an AliveCor single-lead ECG device had reasonable diagnostic accuracy.
Asunto(s)
Arritmias Cardíacas , Electrocardiografía , Humanos , Femenino , Masculino , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Anciano , Persona de Mediana Edad , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Técnicas Electrofisiológicas Cardíacas/instrumentación , Técnicas Electrofisiológicas Cardíacas/métodosRESUMEN
Catheter ablation for atrial fibrillation (AF) has increased exponentially in many developed countries, including Australia and New Zealand. This Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation from the Cardiac Society of Australia and New Zealand (CSANZ) recognises healthcare factors, expertise and expenditure relevant to the Australian and New Zealand healthcare environments including considerations of potential implications for First Nations Peoples. The statement is cognisant of international advice but tailored to local conditions and populations, and is intended to be used by electrophysiologists, cardiologists and general physicians across all disciplines caring for patients with AF. They are also intended to provide guidance to healthcare facilities seeking to establish or maintain catheter ablation for AF.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Australia , Cardiología/normas , Ablación por Catéter/métodos , Ablación por Catéter/normas , Nueva Zelanda , Sociedades MédicasRESUMEN
IMPORTANCE: Randomised trials have shown that catheter ablation (CA) is superior to medical therapy for ventricular tachycardia (VT) largely in patients with ischaemic heart disease. Whether this translates to patients with all forms and stages of structural heart disease (SHD-e.g., non-ischaemic heart disease) is unclear. This trial will help clarify whether catheter ablation offers superior outcomes compared to medical therapy for VT in all patients with SHD. OBJECTIVE: To determine in patients with SHD and spontaneous or inducible VT, if catheter ablation is more efficacious than medical therapy in control of VT during follow-up. DESIGN: Randomised controlled trial including 162 patients, with an allocation ratio of 1:1, stratified by left ventricular ejection fraction (LVEF) and geographical region of site, with a median follow-up of 18-months and a minimum follow-up of 1 year. SETTING: Multicentre study performed in centres across Australia. PARTICIPANTS: Structural heart disease patients with sustained VT or inducible VT (n=162). INTERVENTION: Early treatment, within 30 days of randomisation, with catheter ablation (intervention) or initial treatment with antiarrhythmic drugs only (control). MAIN OUTCOMES, MEASURES, AND RESULTS: Primary endpoint will be a composite of recurrent VT, VT storm (≥3 VT episodes in 24 hrs or incessant VT), or death. Secondary outcomes will include each of the individual primary endpoints, VT burden (number of VT episodes in the 6 months preceding intervention compared to the 6 months after intervention), cardiovascular hospitalisation, mortality (including all-cause mortality, cardiac death, and non-cardiac death) and LVEF (assessed by transthoracic echocardiography from baseline to 6-, 12-, 24- and 36-months post intervention). CONCLUSIONS AND RELEVANCE: The Catheter Ablation versus Anti-arrhythmic Drugs for Ventricular Tachycardia (CAAD-VT) trial will help determine whether catheter ablation is superior to antiarrhythmic drug therapy alone, in patients with SHD-related VT. TRIAL REGISTRY: Australian New Zealand Clinical Trials Registry (ANZCTR) TRIAL REGISTRATION ID: ACTRN12620000045910 TRIAL REGISTRATION URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=377617&isReview=true.
Asunto(s)
Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Antiarrítmicos/uso terapéutico , Volumen Sistólico , Estudios Prospectivos , Resultado del Tratamiento , Función Ventricular Izquierda , Australia/epidemiología , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Isquemia Miocárdica/cirugía , Ablación por Catéter/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como AsuntoRESUMEN
Cardiac arrhythmias are associated with significant morbidity, mortality and economic burden on the health care system. Detection and surveillance of cardiac arrhythmias using medical grade non-invasive methods (electrocardiogram, Holter monitoring) is the accepted standard of care. Whilst their accuracy is excellent, significant limitations remain in terms of accessibility, ease of use, cost, and a suboptimal diagnostic yield (up to â¼50%) which is critically dependent on the duration of monitoring. Contemporary wearable and handheld devices that utilise photoplethysmography and the electrocardiogram present a novel opportunity for remote screening and diagnosis of arrhythmias. They have significant advantages in terms of accessibility and availability with the potential of enhancing the diagnostic yield of episodic arrhythmias. However, there is limited data on the accuracy and diagnostic utility of these devices and their role in therapeutic decision making in clinical practice remains unclear. Evidence is mounting that they may be useful in screening for atrial fibrillation, and anecdotally, for the diagnosis of other brady and tachyarrhythmias. Recently, there has been an explosion of patient uptake of such devices for self-monitoring of arrhythmias. Frequently, the clinician is presented such information for review and comment, which may influence clinical decisions about treatment. Further studies are needed before incorporation of such technologies in routine clinical practice, given the lack of systematic data on their accuracy and utility. Moreover, challenges with regulation of quality standards and privacy remain. This state-of-the-art review summarises the role of novel ambulatory, commercially available, heart rhythm monitors in the diagnosis and management of cardiac arrhythmias and their expanding role in the diagnostic and therapeutic paradigm in cardiology.
Asunto(s)
Fibrilación Atrial , Dispositivos Electrónicos Vestibles , Humanos , Electrocardiografía Ambulatoria/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , ElectrocardiografíaRESUMEN
BACKGROUND: There are differences in substrate and ablation approaches for ventricular tachycardia (VT) in ischaemic (ICM) and non-ischaemic cardiomyopathy (NICM). OBJECTIVE: To perform a systematic review and meta-analysis comparing clinical and procedural characteristics/outcomes of VT ablation in ICM versus NICM. METHODS: Electronic databases were searched for comparative studies reporting outcomes of VT ablation in patients with ICM and NICM. Primary outcomes were acute procedural success, VT recurrence and long-term mortality. Meta-analyses were performed using random-effects modelling. RESULTS: Thirty-one (31) studies (7,473 patients; 4,418 ICM and 3,055 NICM) were included. Patients with ICM were significantly older (67.0 vs 55.3 yrs), more commonly male (89% vs 79%), had lower left ventricular ejection fraction (29% vs 38%) were less likely to undergo epicardial access (11% vs 36%) and were more likely to require haemodynamic support during ablation (relative risk [RR] 1.30; 95% CI 1.01-1.69). Acute procedural success (i.e. non-inducibility of VT) was higher in the ICM cohort (RR 1.10, 95% CI 1.05-1.15). Recurrence of VT at follow-up was significantly lower in the ICM cohort (RR 0.77; 95% CI 0.70-0.84). Peri-procedural mortality, incidence of procedural complications and long-term mortality were not significantly different between the cohorts. CONCLUSIONS: NICM and ICM patients undergoing VT ablation are fundamentally different in their clinical characteristics, ablation approaches, acute procedural outcomes and likelihood of VA recurrence. VT ablation in NICM has a lower likelihood of procedural success with increased risk of VA recurrence, consistent with known challenging arrhythmia substrate.
Asunto(s)
Cardiomiopatías , Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Cardiomiopatías/complicaciones , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Humanos , Masculino , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Recurrencia , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular IzquierdaRESUMEN
BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) can provide circulatory support in high-risk patients undergoing drug refractory ventricular tachycardia (VT) ablation procedures. We report experience using VA-ECMO in a pre-emptive approach for high-risk patients with VT storm and previously ineffective ablation procedures. METHODS AND RESULTS: Four (4) patients with drug refractory ventricular tachycardia (mean age 61±3 years; left ventricular ejection fraction 21±5%) presenting for VT ablation had pre-emptive VA-ECMO. All patients during current admission had VT storm. Pre-ablation, 22 total monomorphic VTs (cycle length 402±69 ms) were induced or spontaneously observed (median of 4, IQR25-75% 1-6). At the end of the procedure, 86% of all inducible VTs were rendered non-inducible. Median hospitalisation following VA-ECMO supported ablation was 5 days (IQR25-75% 3-12). During follow-up (median 138 days [IQR25-75% 57-277]), VT recurred in one patient as an isolated episode reverted by anti-tachycardia pacing. There was a 99% reduction in VT burden post ablation. One (1) patient died of cardiogenic shock within 24 hours whilst still on VA-ECMO, all other patients were successfully weaned off support and discharged. Two (2) patients underwent cardiac transplantation at 199 and 512 days post ablation following implantation of ventricular assist devices for worsening heart failure. CONCLUSIONS: The pre-emptive use of VA-ECMO for high-risk patients undergoing catheter ablation for VT storm was found to be effective in maintaining haemodynamic status, and allowing successful mapping and catheter ablation for VT.
Asunto(s)
Ablación por Catéter , Oxigenación por Membrana Extracorpórea , Taquicardia Ventricular , Australia/epidemiología , Humanos , Persona de Mediana Edad , Volumen Sistólico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular IzquierdaRESUMEN
The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.
Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Pandemias , Neumonía Viral , Australia/epidemiología , COVID-19 , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/fisiopatología , Infecciones por Coronavirus/terapia , Humanos , Neumonía Viral/epidemiología , Neumonía Viral/fisiopatología , Neumonía Viral/terapia , SARS-CoV-2RESUMEN
Catheter ablation has become standard of care in patients with symptomatic atrial fibrillation (AF). Although there have been significant advances in our understanding and technology, a substantial proportion of patients have ongoing AF requiring repeat procedures. Pulmonary vein isolation (PVI) is the cornerstone of AF ablation; however, it is less effective in patients with persistent as opposed to paroxysmal atrial fibrillation. Left atrial posterior wall isolation (PWI) is commonly performed as an adjunct to PVI in patients with persistent AF with nonrandomized studies showing improved outcomes. Anatomical considerations and detailed outline of the various approaches and techniques to performing PWI are detailed, and advantages and pitfalls to assist the clinical electrophysiologist successfully and safely complete PWI are described.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Radiografía Intervencional , Resultado del TratamientoRESUMEN
BACKGROUND: Patch clamping studies using non-cardiomyocytes revealed that the human connexin40 mutations P88S, G38D, and A96S are associated with reduced gap junction conductances compared to wild type connexin40 (wtCx40). Their effects within myocytes however are unclear. We aimed to characterise P88S, G38D, and A96S after expression in rat hearts and primary cardiomyocyte cultures. METHODS: Adult Sprague-Dawley rat atria were transduced with a lentivector containing a transgene encoding wtCx40, P88S, G38D, A96S, or eGFP (n=6 per transgene). Electrophysiology studies (EPS) were performed just prior to and 7 days after surgery. Left atria were assessed for connexin expression, mRNA levels, inflammation and fibrosis. Primary cardiomyocyte cultures were also transduced with the abovementioned vectors (n=6 per transgene) and monolayer conduction velocities (CV) and protein expression were assessed at 96hours. RESULTS: At day 7 EPS, P wave and induced atrial fibrillation (AF) durations were significantly longer in the mutant groups when compared to wtCx40 controls (p<0.05). There were no significant differences in inflammation, fibrosis, or heart to body weight ratios. Monolayer CV's were reduced in the A96S group compared to the wtCx40 group. While similar to wtCx40 controls, P88S velocities were reduced compared to eGFP controls. G38D monolayers possessed spontaneous fibrillatory activity and could not be paced. Immunofluorescence revealed that P88S and G38D reduced native connexin43 myocyte coupling while A96S appeared to co-localise with connexin43 in gap junctions. Connexin43 mRNA levels were similar between groups. CONCLUSIONS: The A96S, G38D, and P88S Cx40 mutations slow conduction and increased the propensity for inducible AF.
Asunto(s)
Fibrilación Atrial/genética , Conexinas/genética , ADN/genética , Mutación , Miocitos Cardíacos/patología , Animales , Fibrilación Atrial/metabolismo , Fibrilación Atrial/patología , Western Blotting , Conexinas/metabolismo , Análisis Mutacional de ADN , Modelos Animales de Enfermedad , Uniones Comunicantes , Humanos , Miocitos Cardíacos/metabolismo , Ratas , Ratas Sprague-Dawley , Proteína alfa-5 de Unión ComunicanteRESUMEN
Atrial fibrillation (AF) is the most common arrhythmia in humans and is known to be associated with an increased risk of stroke, dementia, heart failure and mortality. Non-pharmacological therapy with ablation using either surgical or percutaneous techniques is recommended in drug refractory AF. Early attempts to devise procedures to ablate AF and restore sinus rhythm culminated with the Cox-Maze procedure, the first truly successful procedure. Since then, ablation surgery has been conducted predominately as a concomitant procedure. The Cox Maze procedure is complex and technically demanding and has, therefore, been extensively modified with new techniques for creating the linear ablation lines, new lesion sets, minimally invasive surgical techniques and most recently hybrid surgical-catheter ablation techniques. Surgical ablation techniques result in a marked reduction in atrial fibrillation when compared to conventional therapy with only a small increase in procedural risk. However, further research is required to more accurately quantify those benefits and to determine the optimal lesion sets, specific to the underlying arrhythmia mechanism and the optimal energy sources for ablation.
Asunto(s)
Técnicas de Ablación/métodos , Fibrilación Atrial/cirugía , Sistema de Conducción Cardíaco/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Accidente Cerebrovascular/prevención & control , Fibrilación Atrial/complicaciones , Humanos , Accidente Cerebrovascular/etiología , Resultado del TratamientoRESUMEN
UNLABELLED: Steam pop is an explosive rupture of cardiac tissue caused by tissue overheating above 100 °C, resulting in steam formation, predisposing to serious complications associated with radiofrequency (RF) ablations. However, there are currently no reliable techniques to predict the occurrence of steam pops. We propose the utility of acoustic signals emitted during RF ablation as a novel method to predict steam pop formation and potentially prevent serious complications. METHODS: Radiofrequency generator parameters (power, impedance, and temperature) were temporally recorded during ablations performed in an in vitro bovine myocardial model. The acoustic system consisted of HTI-96-min hydrophone, microphone preamplifier, and sound card connected to a laptop computer. The hydrophone has the frequency range of 2 Hz to 30 kHz and nominal sensitivity in the range -240 to -165 dB. The sound was sampled at 96 kHz with 24-bit resolution. Output signal from the hydrophone was fed into the camera audio input to synchronize the video stream. An automated system was developed for the detection and analysis of acoustic events. RESULTS: Nine steam pops were observed. Three distinct sounds were identified as warning signals, each indicating rapid steam formation and its release from tissue. These sounds had a broad frequency range up to 6 kHz with several spectral peaks around 2-3 kHz. Subjectively, these warning signals were perceived as separate loud clicks, a quick succession of clicks, or continuous squeaking noise. Characteristic acoustic signals were identified preceding 80% of pops occurrence. Six cardiologists were able to identify 65% of acoustic signals accurately preceding the pop. An automated system identified the characteristic warning signals in 85% of cases. The mean time from the first acoustic signal to pop occurrence was 46 ± 20 seconds. The automated system had 72.7% sensitivity and 88.9% specificity for predicting pops. CONCLUSIONS: Easily identifiable characteristic acoustic emissions predictably occur before imminent steam popping during RF ablations. Such acoustic emissions can be carefully monitored during an ablation and may be useful to prevent serious complications during RF delivery.
Asunto(s)
Acústica , Ablación por Catéter/efectos adversos , Ventrículos Cardíacos/cirugía , Ruido , Procesamiento de Señales Asistido por Computador , Vapor/efectos adversos , Acústica/instrumentación , Animales , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Bovinos , Diseño de Equipo , Ventrículos Cardíacos/patología , Miocardio/patología , Espectrografía del Sonido , Factores de Tiempo , TransductoresRESUMEN
The Cardiac Society of Australia and New Zealand (CSANZ) Position Statement describes evidence-based standards of training, pre-procedural assessment, procedural conduct and post-procedure care with respect to sedation for cardiovascular procedures. It also describes the environment in which sedation for electrophysiological and other cardiac procedures may be performed. This Statement was developed by a Working Group of the Cardiac Society of Australia and New Zealand. It was reviewed by the Continuing Education and Recertification Committee and ratified at the CSANZ Board meeting held on Friday 7 March 2014.
Asunto(s)
Procedimientos Quirúrgicos Cardiovasculares/métodos , Procedimientos Quirúrgicos Cardiovasculares/normas , Sedación Profunda/métodos , Sedación Profunda/normas , Australia , Femenino , Humanos , Masculino , Nueva Zelanda , Guías de Práctica Clínica como Asunto , Sociedades MédicasRESUMEN
BACKGROUND: Collagen has been attributed as the principal structural substrate of ventricular tachycardia (VT) after myocardial infarction (MI), even though adiposity of myocardium after MI is well recognized histologically. We investigated the effects of intramyocardial adiposity compared with collagen on electrophysiological properties, connexin43 expression, and VT induction after MI. METHODS AND RESULTS: Simultaneous left ventricular plunge-needle, noncontact mapping was performed in sheep without MI (MI-; n=5), with MI and inducible VT (MI+VT+; n=7), and with MI and no inducible VT (MI+VT-; n=8). Histological intramyocardial quantity of adipose and collagen and degree of discontinuity were coregistered with electrophysiological parameters (MI+; 290 specimens). Additional assessment of connexin43 expression was performed. Left ventricular scar contained a body mass-independent abundance of adipocytes (adipose:collagen=0.8). Increased adipose density and discontinuity contributed to a greater inverse correlation (r) with conduction velocity (r for adipose=0.39, r for discontinuity=0.45, r for collagen=0.26) and electrogram amplitude (r for adipose=0.73, r for contiguity=0.77, r for collagen=0.68) compared with collagen. Collagen density was similar between the MI+ groups (P>0.29). However, the MI+VT+ group demonstrated a significant (all P≤0.01) increase in adipose (8%) and discontinuity (qualitative) and decrease in conduction velocity (13%) and electrogram amplitude (21%) at MI borders compared with the MI+VT- group. In scar, myocytes adjacent to fibrofatty interfaces demonstrated increased connexin43 lateralization. A gradient increase in adipose was observed at sites that supported preferential presystolic VT activation and exhibited attenuation of excitation wavelength (P<0.001). CONCLUSIONS: Intramyocardial adiposity, in association with myocardial discontinuity within left ventricular scar borders, is a significant factor associated with altered electrophysiological properties, aberrant connexin43 expression, and increased propensity for VT after MI.
Asunto(s)
Adiposidad , Infarto del Miocardio/patología , Miocardio/patología , Taquicardia Ventricular/patología , Animales , Colágeno/metabolismo , Conexina 43/metabolismo , Modelos Animales de Enfermedad , Técnicas Electrofisiológicas Cardíacas , Uniones Comunicantes/metabolismo , Uniones Comunicantes/patología , Sistema de Conducción Cardíaco/metabolismo , Sistema de Conducción Cardíaco/patología , Masculino , Infarto del Miocardio/metabolismo , Infarto del Miocardio/fisiopatología , Miocardio/metabolismo , Orquiectomía , Ovinos , Taquicardia Ventricular/metabolismo , Taquicardia Ventricular/fisiopatología , Remodelación Ventricular/fisiologíaRESUMEN
Administration of intravenous sedation (IVS) has become an integral component of procedural cardiac electrophysiology. IVS is employed in diagnostic and ablation procedures for transcutaneous treatment of cardiac arrhythmias, electrical cardioversion of arrhythmias, and the insertion of implantable electronic devices including pacemakers, defibrillators, and loop recorders. Sedation is frequently performed by nursing staff under the supervision of the proceduralist and in the absence of specialist anesthesiologists. The sedation requirements vary depending on the nature of the procedure. A wide range of sedation techniques have been reported with sedation from the near fully conscious to levels approaching that of general anesthesia. This review examines the methods employed and outcomes associated with reported sedation techniques. There is a large experience with the combination of benzodiazepines and narcotics. These drugs have a broad therapeutic range and the advantage of readily available reversal agents. More recently, the use of propofol without serious adverse events has been reported. The results provide a guide regarding the expected outcomes of these approaches. The complication rate and need for emergency assistance is low in reported series where sedation is administered by nonspecialist anesthesiology staff.
Asunto(s)
Anestesia General/métodos , Técnicas Electrofisiológicas Cardíacas/efectos adversos , Técnicas Electrofisiológicas Cardíacas/métodos , Hipnóticos y Sedantes/administración & dosificación , Dolor/etiología , Dolor/prevención & control , HumanosRESUMEN
BACKGROUND: Organized atrial tachycardias (OATs) after pulmonary vein isolation (PVI) procedure are common. Arrhythmia mechanisms include mitral annular, ring gap, or roof-dependent gap-related flutters. In this series, we describe a mechanism of arrhythmia utilizing the ridge between left pulmonary vein (PV) and left atrial appendage (LAA) in the Ligament of Marshall (LOM) region. METHODS AND RESULTS: Five tachycardias involving the LOM region were identified from a group of 240 patients who underwent a single ring PVI procedure for symptomatic atrial fibrillation. The common characteristics of these tachycardias were the endocardial breakout over a broad area adjacent to the LOM region, presence of presystolic or mid-diastolic potentials, and abolition by ablation of the presystolic or mid-diastolic potentials remote from the endocardial breakout site. In all five cases, tachycardias were present after isolation of the veins and posterior left atria. All demonstrated characteristic areas of very slow conduction in the LOM region highlighted by presence of either low voltage, long duration fractionated potentials, or mid-diastolic potentials with a fixed temporal relationship to the subsequent endocardial activation. The pattern of activation and termination of tachycardia during ablation was consistent with an arrhythmia utilizing an electrically insulated tract within LOM and the PV-LAA ridge region. CONCLUSIONS: We identified a pattern of arrhythmias involving a concealed presystolic component and a broad endocardial breakout site related to the LOM region. Successful ablation site involved careful identification of small diastolic potentials in the LAA/ridge region or adjacent to the coronary sinus.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ligamentos/cirugía , Venas Pulmonares/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Anciano , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Transcatheter renal denervation (RDN) has had inconsistent efficacy and concerns for durability of denervation. We aimed to investigate long-term safety and efficacy of transcatheter microwave RDN in vivo in normotensive sheep in comparison to conventional radiofrequency ablation. METHODS AND RESULTS: Sheep underwent bilateral RDN, receiving 1 to 2 microwave ablations (maximum power of 80-120 W for 240 s-480 s) and 12 to 16 radiofrequency ablations (180 s-240 s) in the main renal artery in a paired fashion, alternating the side of treatment, euthanized at 2 weeks (acute N=15) or 5.5 months (chronic N=15), and compared with undenervated controls (N=4). Microwave RDN produced substantial circumferential perivascular injury compared with radiofrequency at both 2 weeks [area 239.8 (interquartile range [IQR] 152.0-343.4) mm2 versus 50.1 (IQR, 32.0-74.6) mm2, P <0.001; depth 16.4 (IQR, 13.9-18.9) mm versus 7.5 (IQR, 6.0-8.9) mm P <0.001] and 5.5 months [area 20.0 (IQR, 3.4-31.8) mm2 versus 5.0 (IQR, 1.4-7.3) mm2, P=0.025; depth 5.9 (IQR, 1.9-8.8) mm versus 3.1 (IQR, 1.2-4.1) mm, P=0.005] using mixed models. Renal denervation resulted in significant long-term reductions in viability of renal sympathetic nerves [58.9% reduction with microwave (P=0.01) and 45% reduction with radiofrequency (P=0.017)] and median cortical norepinephrine levels [71% reduction with microwave (P <0.001) and 72.9% reduction with radiofrequency (P <0.001)] at 5.5 months compared with undenervated controls. CONCLUSIONS: Transcatheter microwave RDN produces deep circumferential perivascular ablations without significant arterial injury to provide effective and durable RDN at 5.5 months compared with radiofrequency RDN.
Asunto(s)
Riñón , Microondas , Arteria Renal , Simpatectomía , Animales , Microondas/uso terapéutico , Microondas/efectos adversos , Simpatectomía/métodos , Simpatectomía/efectos adversos , Arteria Renal/inervación , Riñón/inervación , Riñón/irrigación sanguínea , Ovinos , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Factores de Tiempo , Modelos Animales de Enfermedad , Presión Sanguínea/fisiología , Femenino , Ablación por Radiofrecuencia/métodos , Ablación por Radiofrecuencia/efectos adversosRESUMEN
BACKGROUND: Radiofrequency (RF) ablation causes thermal mediated irreversible myocardial necrosis. This study aimed to (i) characterize the thermal characteristics of RF ablation lesions with high spatial resolution using a thermochromic liquid crystal (TLC) myocardial phantom; and (ii) compare the thermochromic lesions with in vivo and in vitro ablation lesions. METHODS AND RESULTS: The myocardial phantom was constructed from a vertical sheet of TLC film, with color change between 50 °C (red) to 78 °C (black), embedded within a gel matrix, with impedance titrated to equal that of myocardium. Saline, with impedance titrated to blood values at 37 °C, was used as supernatant. A total of 51 RF ablations were performed. This comprised 17 ablations in the thermochromic gel phantom, bovine myocardial in vitro targets and ovine in vivo ablations, respectively. There was no difference in lesion dimensions between the thermochromic gel and in vivo ablations (lesion width 10.2 ± 0.2 vs 10.2 ± 2.4, P = 0.93; and depth 6.3 ± 0.1 vs 6.5 ± 1.7, P = 0.74). The spatial resolution of the thermochromic film was tested using 2 thermal point-sources that were progressively opposed and was demonstrated to be <300 µm. CONCLUSIONS: High spatial resolution thermal mapping of in vitro RF lesions with spatial resolution of at least 300 µm is possible using a thermochromic liquid crystal myocardial phantom model, with a good correlation to in vivo RF ablations. This model may be useful for assessing the thermal characteristics of RF lesions created using different ablation parameters and catheter technologies.
Asunto(s)
Ablación por Catéter , Cristales Líquidos , Miocardio/patología , Fantasmas de Imagen , Temperatura , Termografía/instrumentación , Animales , Bovinos , Geles , Modelos Animales , Necrosis , OvinosRESUMEN
BACKGROUND: Women are under-represented in many key studies and trials examining outcomes of catheter ablation (CA) for ventricular arrhythmias (VA). We compared characteristics between men and women undergoing their first catheter ablation for VA at a single centre over 10 years. METHODS: The clinical, procedural characteristics and outcomes of 287 consecutive patients (male = 182, female = 105), undergoing their first CA at our centre over 10 years were compared according to sex and underlying heart disease. RESULTS: In the ablation population, women were younger, had fewer co-morbidities, were less likely to have ischemic cardiomyopathy (ICM) and VA storm and were more likely to have idiopathic VA and premature ventricular complexes as the indication for ablation (P < 0.05 for all). Amongst idiopathic and non-ischemic cardiomyopathy (NICM) subgroups, baseline characteristics were similar; amongst ICM, women were younger and had higher numbers of drug failure pre-ablation (P = 0.05). Women were similar to men in all procedural characteristics, acute procedural success and complications, regardless of underlying heart disease. At median follow-up of 666 days, VA-free survival, overall mortality and survival free of death or transplant were comparable in both groups. Sex was not a predictor of these outcomes, after accounting for clinical and procedural characteristics. CONCLUSION: Women represented 36% of the real-world population at our centre referred for CA of VA. There are key differences in clinical features of women versus men referred for VA ablation. Despite these differences, VA ablation in women can be accomplished with similar success and complication rates to men, regardless of underlying heart disease.
Asunto(s)
Cardiomiopatías , Ablación por Catéter , Cardiopatías , Isquemia Miocárdica , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Humanos , Masculino , Femenino , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Isquemia Miocárdica/complicaciones , Complejos Prematuros Ventriculares/cirugía , Ablación por Catéter/efectos adversos , Cardiomiopatías/complicaciones , Cardiomiopatías/cirugíaRESUMEN
BACKGROUND: Radiofrequency (RF) ablation utilizing direct endocardial visualization (DEV) requires a "virtual electrode" to deliver RF energy while preserving visualization. This study aimed to: (1) examine the virtual electrode RF ablation efficacy; (2) determine the optimal power and duration settings; and (3) evaluate the utility of virtual electrode unipolar electrograms. METHODS AND RESULTS: The DEV catheter lesions were compared to lesions formed using a 3.5 mm open irrigated tip catheter within the right atria of 12 sheep. Generator power settings for DEV were titrated from 12W, 14W and 16W for 20, 30 and 40 seconds duration with 25 mL/min saline irrigation. Standard irrigated tip catheter settings of 30W, 50°C for 30 seconds and 30 mL/min were used. The DEV lesions were significantly greater in surface area and both major and minor axes compared to irrigated tip lesions (surface area 19.43 ± 9.09 vs 10.88 ± 4.72 mm, P<0.01) with no difference in transmurality (93/94 vs 46/47) or depth (1.86 ± 0.75 vs 1.85 ± 0.57 mm). Absolute electrogram amplitude reduction was greater for DEV lesions (1.89 ± 1.31 vs 1.49 ± 0.78 mV, P = 0.04), but no difference in percentage reduction. Pre-ablation pacing thresholds were not different between DEV (0.79 ± 0.36 mA) and irrigated tip (0.73 ± 0.25 mA) lesions. There were no complications noted during ablation with either catheter. CONCLUSIONS: Virtual electrode ablation consistently created wider lesions at lower power compared to irrigated tip ablation. Virtual electrode electrograms showed a comparable pacing and sensing efficacy in detecting local myocardial electrophysiological changes.