Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 125
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Surg ; 75(4): 1242-1252.e2, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34634415

RESUMEN

OBJECTIVE: In recent years, manufacturers have developed new stent grafts with lower profiles to increase the endovascular aneurysm repair applicability. As reported by the current European Society for Vascular Surgery guidelines, long-term evaluation of such low-profile platforms is strongly recommended. This study aims to report outcomes beyond 5 years from a multicenter registry, including a real-world cohort of patients electively treated with low-profile stent grafts. METHODS: A retrospective data collection of patients who had undergone elective implantation of low-profile endograft ≤16 Fr. (Zenith LP, Ovation, Incraft) was performed in nine centers. The primary endpoint was a long-term primary clinical success. Secondary endpoints were survival rate, freedom from abdominal aortic aneurysm (AAA)-related death, freedom from type I to III endoleak, limb patency, and freedom from all reinterventions. The Kaplan-Meier curves were stratified for investigative devices. A multivariate analysis evaluated predictors of primary clinical success and reintervention rate. RESULTS: A total of 619 patients were enrolled (Ovation, n = 373; Incraft, n = 111; and Zenith LP, n = 135), with a mean follow-up of 56.8 ± 22.8 months. The overall primary and the secondary clinical success rate at 8 years was 72.1% and 93.8%, respectively. At 8 years, overall survival was 53.2%, freedom from AAA-related death was 94.4%, freedom from reintervention was 74%, freedom from type I/III endoleak was 86.9%, and limb patency was 90.4%. A significantly worse primary clinical success of the Zenith LP was recorded as dependent on more limb-related events. No differences between platforms were registered in the rate of AAA-related deaths, open conversion, sac enlargement, and type I/III endoleaks (P = .26). Multivariate analysis identified iliac tortuosity (hazard ratio, 2.053) and Zenith LP (hazard ratio, 3.818) as significant independent predictors of clinical failure and reintervention. CONCLUSIONS: Low-profile stent grafts have acceptable long-term outcomes. Overall survival and AAA-related death were in line with those reported for traditional devices. Long-term surveillance and reintervention, when necessary, remain crucial to guarantee durability.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Endofuga/epidemiología , Endofuga/etiología , Endofuga/terapia , Humanos , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Stents , Resultado del Tratamiento
2.
J Vasc Surg ; 74(4): 1222-1231.e2, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33864827

RESUMEN

OBJECTIVE: Abdominal aortic aneurysm (AAA) sac shrinkage after endovascular aortic repair (EVAR) has been regarded as positive marker of EVAR success durability. The purpose of this study was to describe the morphovolumetric changes of the AAA sac during follow-up after elective EVAR and to analyze sac shrinkage-related variables. METHODS: This is a single-center, retrospective, observational cohort study from a tertiary referral university hospital. All patients treated with EVAR between January 2013 and December 2018 were identified. Inclusion criteria were elective EVAR for AAA, preoperative computed tomography angiography within 6 months before EVAR and at least one postoperative computed tomography angiography during the follow-up, using a standardized protocol. Aneurysm sac shrinkage was defined as diameter decrease of 1 cm or more, volume shrinkage threshold was identified by a 16% decrease compared with the preoperative value. Primary outcomes were early (≤30 days) and late survival, and freedom from aneurysm-related mortality (ARM), and aortic reintervention. RESULTS: There were 149 of the 325 patients (45.8%) who met the inclusion criteria: 133 (89.3%) were male and 16 (10.7%) female. The mean age was 74 ± 7 years (range, 55-87 years); the median AAA diameter was 56 mm (interquartile range, 50.0-61.2 mm) and the median volume was 138.8 cm3 (range, 99.0-178.3 cm3). Primary technical success was achieved in 145 patients (97.3%). The in-hospital mortality rate was 1.3%. The median follow-up was 42 months (interquartile range, 22.5-58.0 months). Both AAA diameter and volume decreased (P = .001 and P = .035, respectively) compared with preoperative measurements. Diameter shrinkage was adjudicated in 27 patients (18.1%), volume shrinkage was observed in 42 patients (28.2%). A Cox regression analysis demonstrated an association between the AAA diameter shrinkage and the preoperative diameter (P = .002; hazard ratio, 1.03; 95% confidence interval [CI], 1.011-1.052). The presence of a persistent endoleak predicted the absence of volume shrinkage (P = .001; hazard ratio, 7.75; 95% CI, 2.282-26.291). The estimated freedom from ARM was 97.5 ± 1.0% (95% CI, 93-99) at 12 months, and 96 ± 2% (95% CI, 90-98) at both 36 and 60 months. Aortic reintervention during the follow-up period was necessary in 7 patients (4.7%). ARM was only observed in the group characterized by the concomitant absence of diameter and volume shrinkage. CONCLUSIONS: Volumetric analysis showed to have higher sensitivity than the simple two-dimensional measurement of the diameter to study AAA sac changes after EVAR. Although no predictor was found to be associated with AAA volume shrinkage, ARM occurred only in the group of AAAs with the absence of volume shrinkage.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Aortografía , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Quirúrgicos Electivos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Retratamiento , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Nutr Metab Cardiovasc Dis ; 31(1): 44-51, 2021 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-32981800

RESUMEN

BACKGROUND AND AIMS: The aims of this study were to identify dietary patterns in a general population of North Italian adults and to investigate the cross-sectional association between prevalent dietary patterns and arterial stiffness. METHODS AND RESULTS: Participants to the RoCAV study without chronic diseases at recruitment and with reliable dietary data were included. The food-frequency EPIC questionnaire was used to evaluate dietary habits. Dietary patterns were estimated using principal components analysis and Mediterranean diet adherence score (MedS). Carotid-femoral pulse wave velocity (cfPWV) was used as proxy of arterial stiffness. Basing on data from 2640 subjects (1608 men and 1032 women, mean ± SD 65.5 ± 6.7 years), four principal components (PC) were retained, explaining 24% of the overall variance. Considering 1284 subjects with cfPWV (mean ± SD 10.7 ± 2.5 m/s) data available, adherence to PC1 (Western-like dietary pattern) was associated with higher stiffness values (+0.29 m/s cfPWV for 1 SD increase of PC1, 95% CI:0.08,0.50; p = 0.007) in a multivariate model. Conversely, adherence to PC2 (Mediterranean-like) was not related to cfPWV values (-0.18, 95% CI: -0.36, 0.004; p = 0.06). Likewise, MedS and other PC patterns did not show any significant association with cfPWV. Mediation analysis showed that the association between Western-like dietary pattern and cfPWV is mediated by higher levels of leucocytes (9.2% of the effect, p = 0.047). CONCLUSIONS: Our study in a Southern European population identified a Western-like dietary pattern associated with an increased cfPWV, a proxy of arterial stiffness. The association with cfPWV was in part mediated by inflammatory status.


Asunto(s)
Enfermedades Cardiovasculares/epidemiología , Dieta Occidental/efectos adversos , Conducta Alimentaria , Rigidez Vascular , Anciano , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/prevención & control , Velocidad de la Onda del Pulso Carotídeo-Femoral , Estudios Transversales , Encuestas sobre Dietas , Dieta Saludable , Dieta Mediterránea , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Factores Protectores , Medición de Riesgo , Conducta de Reducción del Riesgo
4.
Ann Vasc Surg ; 72: 667.e1-667.e9, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33338572

RESUMEN

BACKGROUND: We aimed to describe the operative outcomes following open aortoiliac/femoral graft reconstruction for bilateral kissing-stent (KS) occlusion. METHODS: This is a bicentric, retrospective, observational cohort study. Between September 2007 and December 2019, 205 patients were treated with KS for aortoiliac reconstruction. Only those who had bilateral KS occlusion with subsequent aortoiliac/femoral graft replacement were included in this analysis. Primary outcomes were early (<30 days) and late survival, postoperative (<30 days) complications, and patency rates. RESULTS: Nine patients (male, n = 7) were analyzed. The patient's mean age was 60 ± 5 years (range 55-62). Median delay from initial KS procedure was 36 months (interquartile range [IQR] 19-252). On admission, all patients presented with a worse Rutherford class compared to their initial pre-KS clinical presentation. Aortobifemoral bypass was performed in 5 patients, and aortobi-iliac reconstruction in 4 patients. There were no perioperative deaths and only 1 new case of erectile dysfunction occurred. At a median follow-up time of 24 months (IQR 12-54), primary patency rate was 88.9%. CONCLUSIONS: Open aortic reconstruction after KS occlusion was feasible and effective. Endovascular repair for aortoiliac obstructive disease may be pursued as first-line treatment even in complex lesions.


Asunto(s)
Enfermedades de la Aorta/terapia , Implantación de Prótesis Vascular , Remoción de Dispositivos , Procedimientos Endovasculares/efectos adversos , Enfermedad Arterial Periférica/terapia , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Enfermedades de la Aorta/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Arterial Periférica/cirugía , Falla de Prótesis , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
5.
Med Lav ; 112(4): 268-278, 2021 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-34446685

RESUMEN

BACKGROUND: High pulse wave velocity (PWV) and low ankle brachial index (ABI) have been proposed as surrogate end-points for cardiovascular disease (CVD). OBJECTIVES: In a cross-sectional setting, we aimed at assessing the distributions of PWV and ABI among occupational classes (OC) in a population-based ever-employed salaried sample. METHODS: We enrolled 1388 salaried CVD-free workers attending a CVD population-based survey, the RoCAV study, and classified them into four OC, based on current or last job title: manager/director (MD), non-manual (NMW), skilled-manual (SMW) and (UMW) unskilled-manual workers. We derived brachial-ankle PWV and ABI from four-limb blood pressures measurements, then carotid-femoral PWV (cfPWV) was estimated. We estimated the OC gradients in cfPWV and ABI using linear and logistic regression models. RESULTS: Compared to MD (reference category), UMW had higher age- and BMI-adjusted cfPWV mean values both in men (0.63 m/s; 95%CI:0.11-1.16) and women (1.60 m/s; 0.43-2.77), only marginally reduced when adjusting for CVD risk factors. Decreased ABI mean values were also detected in lower OC. The overall detection rate of abnormal cfPWV (≥12 m/s) or ABI (≤0.9) values was 28%. Compared to MD, the prevalence of abnormal cfPWV or ABI was higher in NMW (OR=1.77; 95%CI:1.12-2.79), SMW (1.71; 1.05-2.78) and UMW (2.72; 1.65-4.50). Adjustment for CVD risk factors used in risk score equations did not change the results. DISCUSSION: We found a higher prevalence of abnormal values of arterial stiffness measures in lower OC, and these differences were not explained by traditional CVD risk factors. These may be presumably determined by additional work- and environmental-related risk factors.


Asunto(s)
Enfermedades Vasculares , Rigidez Vascular , Índice Tobillo Braquial , Estudios Transversales , Femenino , Humanos , Masculino , Análisis de la Onda del Pulso , Factores de Riesgo
6.
J Vasc Surg ; 71(3): 1036-1045.e1, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31727456

RESUMEN

BACKGROUND: True giant splenic artery aneurysms (GSAAs) >5 cm are rare and present unique therapeutic challenges. The aim of this study was to evaluate the anatomic and clinical characteristics of these lesions and the current surgical and endovascular techniques available for their treatment. METHODS: A systematic review of the literature from 2004 to 2018 and the personal experience of the authors with management of GSAAs are presented. A total of 92 GSAA cases were reviewed. Analyses were performed on anatomic and clinical features and management modalities and outcomes of GSAA, including reintervention, morbidity, and mortality. RESULTS: GSAA presented at a mean age of 56.1 ± 17.3 years, with no sex predilection; 73% were symptomatic at presentation. Abdominal pain was the presenting symptom in >50% of cases; 34% percent were ruptured, with an overall mortality rate of 12.5%. This group often presented with gastrointestinal bleeding or hemodynamic collapse. The aneurysms were almost evenly distributed across the splenic artery and were not uncommonly associated with arteriovenous fistula formation (8.7%). There were 88 patients who had surgical (53.4%), endovascular (44.3%), or combination (2.3%) therapy. The most commonly performed procedure was aneurysmectomy and splenectomy with or without additional resection. Overall, surgical treatment had a lower morbidity (P = .041) than endovascular therapy and comparable reintervention and mortality rates. CONCLUSIONS: GSAAs are uncommon vascular lesions, with distinct clinical features and aneurysm characteristics. Considering their high risk of rupture, timely diagnosis and management are essential to attain a satisfactory outcome. Surgery remains the standard treatment of these lesions. Endovascular intervention is a viable alternative in high-risk patients, particularly those with lesions <10 cm or with anomalous origin.


Asunto(s)
Aneurisma/cirugía , Arteria Esplénica , Enfermedades del Bazo/cirugía , Procedimientos Endovasculares , Humanos , Esplenectomía , Procedimientos Quirúrgicos Vasculares
7.
World J Surg ; 44(6): 2010-2019, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32047985

RESUMEN

BACKGROUND: We present a comparison of renal function outcomes during HTAR with the use of a new hybrid vascular graft (GHVG) or standard graft. METHODS: It is a multicenter, retrospective, observational study. Between January 2015 and March 2019, 36 patients were treated with HTAR. We compared HTAR performed with the use of the GHVG and with the use of standard bypass graft. Primary outcome measures were hospital mortality, acute kidney injury (AKI) at 30 days and GHVG patency. RESULTS: Mean GHVG ischemia time was significantly lower for both renal arteries (right: GHVG, 4 ± 2 vs. standard graft, 15 ± 7 min; 95% CI 2.23-6.69, P < 0.001; left: GHVG, 3 ± 2 vs. standard graft, 13 ± 7 min; 95% CI 2.44-5.03, P < 0.001). Hospital mortality was 17% (6/36); while mortality did not differ between the two groups, postoperative acute kidney injury rate was 30.5% (11/36 patients) and was more common in the standard graft group (7% vs. 29%; OR 3.2, P = 0.074). Estimated primary patency was 92% ± 2 (95% CI 79.5-97%) at 36 months and was not different between the two groups (GHVG 94% ± 6 vs. standard graft 91% ± 6; log-rank χ2 = 0.260, P = 0.610). CONCLUSIONS: In our experience of HTAR, ischemia time was significantly shorter and postoperative AKI occurrence was lower with GHVG if compared to standard graft bypass, with satisfactory midterm patency rate comparable to that of standard graft bypass.


Asunto(s)
Lesión Renal Aguda/etiología , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Injerto Vascular/efectos adversos , Lesión Renal Aguda/fisiopatología , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/efectos adversos , Femenino , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Riñón/cirugía , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Isquemia Tibia
8.
World J Surg ; 44(10): 3545-3554, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32462218

RESUMEN

BACKGROUND: Various techniques have been used for the execution of carotid endarterectomy; primary (PC), patch closure (CP) and eversion technique (ET).The superiority of any of them is still unproven. The aim of this study was to compare the long-term outcomes of each technique in terms of cerebrovascular event (CVE), restenosis, survival and major cardiac event (MACE). METHODS: Between 2007 and 2018, a retrospective analysis of prospectively recorded data from three European tertiary centers was undertaken including 1.357 patients. Demographics, comorbidities and medical treatment were analyzed in relation to long-term outcomes. Freedom from CVE, restenosis (> 70%), survival and MACE were estimated with Kaplan-Meier analysis curve. RESULTS: The mean age was 69.5 ± 8 (72% males;79% asymptomatic). 472 (35%) were treated with PC, 504 (37%) with CP and 381 (28%) with ET. Differences among groups were observed in age (P < 0.001), gender (P < 0.01), hypertension (P = 0.01), dyslipidemia (P < 0.001) and statin treatment (P < 0.001). The mean follow-up was 4.7 ± 3 years (median: 5 years). Seventy-three patients presented a CVE during 8 years of follow-up. The freedom from CVE including all techniques was 96% (SE 0.6%), 93% (SE 1%) and 89% (SE 1.6%), at 2, 5 and 8 years of follow-up, respectively, with no difference between groups (P .289). Freedom from restenosis was at 96% (SE 0.7%) and 89% (SE 5%) at 5 and 10 years, respectively, for all methods without differences. ET was associated with a higher mortality rate (P < 0.001) and MACE rate (P < 0.001). CONCLUSIONS: Excellent outcomes were achieved with all types of closure techniques with low rates of MACE and other adverse events during long-term follow-up after CEA.


Asunto(s)
Endarterectomía Carotidea/efectos adversos , Complicaciones Posoperatorias/epidemiología , Anciano , Enfermedades Cardiovasculares/epidemiología , Endarterectomía Carotidea/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología
9.
Ann Vasc Surg ; 64: 382-388, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31676381

RESUMEN

BACKGROUND: Giant splenic artery pseudoaneurysms (GSAPs) > 5 cm are a rare clinical entity. The aim of this study was to present our experience with 2 such patients successfully treated by coil embolization and surgery and review the pertinent literature. METHODS: A 58-year-old woman and 57-year-old man with a history of chronic pancreatitis were diagnosed with GSAP based on computed tomography (CT) angiography. The first patient had a 6-cm pseudoaneurysm, which was successfully treated with transcatheter coil embolization using a sandwich exclusion method. The second patient had two 7-cm lesions, which were successfully treated with distal pancreatectomy and splenectomy. RESULTS: Postembolization CT angiography at 12 months showed remaining calcified pseudocyst without evidence of pseudoaneurysm in the first patient. Both patients remained well and symptom-free at 12 months. CONCLUSIONS: Combined with the experience of the previous literature, we believe that management of GSAP should be tailored for each individual case depending on the location and number of pseudoaneurysms, the underlying etiology, and the patient's hemodynamic status. Embolization should be considered as the first-line treatment for clinically stable patients with GSAP, whereas GSAPs with a pseudocyst are best treated with surgery.


Asunto(s)
Aneurisma Falso/terapia , Embolización Terapéutica , Pancreatectomía , Esplenectomía , Arteria Esplénica/cirugía , Adulto , Anciano , Aneurisma Falso/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Esplénica/diagnóstico por imagen , Resultado del Tratamiento
10.
Ann Vasc Surg ; 63: 391-398, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31626937

RESUMEN

There is presently a lack of organization and standardized reporting schema for arteriovenous graft (AVG) infections. The purpose of this article is to evaluate the various types of treatment modalities for access site infections through an analysis of current publications on AVG. Key proposals are made to support standardization in a data-driven manner to make infection reporting more uniform and thereby facilitate more meaningful comparisons between various dialysis modalities and AVG technologies.


Asunto(s)
Antibacterianos/uso terapéutico , Derivación Arteriovenosa Quirúrgica/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Prótesis Vascular/efectos adversos , Remoción de Dispositivos/normas , Drenaje/normas , Guías de Práctica Clínica como Asunto/normas , Infecciones Relacionadas con Prótesis/terapia , Reportes Públicos de Datos en Atención de Salud , Diálisis Renal , Proyectos de Investigación/normas , Antibacterianos/efectos adversos , Derivación Arteriovenosa Quirúrgica/instrumentación , Implantación de Prótesis Vascular/instrumentación , Remoción de Dispositivos/efectos adversos , Drenaje/efectos adversos , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/microbiología , Factores de Riesgo , Resultado del Tratamiento
11.
J Vasc Surg ; 70(6): 1904-1912.e2, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31068267

RESUMEN

OBJECTIVE: The aim of our study was to identify patients' characteristics that predicted a higher chance of arteriovenous graft patency in patients undergoing Gore Hybrid Vascular Graft (GHVG; W. L. Gore & Associates, Flagstaff, Ariz) implantation for hemodialysis access. The GHVG is a polytetrafluroethylene (PTFE) prosthesis with a nitinol-reinforced section (NRS) at the venous end. METHODS: All consecutive patients undergoing GHVG implantation for hemodialysis access at 10 tertiary referral centers between December 2013 and January 2018 were included in the study and compared with a control group of patients undergoing standard PTFE graft implantation. Selection of patients for hybrid graft implantation was based on the impossibility of autogenous vascular access creation. RESULTS: There were 145 patients included in the GHVG group and 218 in the PTFE group. In the GHVG and the PTFE groups, the mean age was 67 ± 13 years and 65 ± 13 years, and male patients totaled 52% and 46%, respectively. The technical success was 99%. The mean duration of the intervention was 100 minutes (median, 95 minutes; interquartile range, 80-120 minutes). The brachial-axillary configuration was used in the majority of cases (n = 78 [54%]). The 5-cm NRS length was prevalent (n = 108 [75%]). The median NRS oversize was 14% (interquartile range, 0%-21%). Mean follow-up was 13 months (range, 0-55 months). Seventy-one patients (49%) underwent at least one reintervention. Primary, assisted primary, and secondary patency estimates at 12 months were 44% ± 5%, 47% ± 5%, and 65% ± 4% for the GHVG group and 41% ± 4%, 53% ± 4%, and 75% ± 3% for the control group, respectively (P = NS). One-year survival was 90% ± 3%. On multivariable Cox regression analysis, hypotension (P < .001; hazard ratio [HR], 5.8; confidence interval [CI], 2.6-13) and diabetes (P = .024; HR, 1.9; CI, 1.1-3.2) were significant predictors of GHVG loss. A larger graft size was protective against GHVG loss (P = .042; HR, 0.73; CI, 0.54-0.99). The 10-cm-long graft showed a tendency toward improved patency but did not reach statistical significance (P = .074; HR, 0.48; CI, 0.21-1.07). CONCLUSIONS: Diabetes and hypotension were predictors of loss of hybrid arteriovenous access. Smaller diameters of NRS were more prone to thrombosis, whereas the 10-cm length seemed to perform better than the 5-cm one.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Prótesis Vascular , Sistema de Registros , Diálisis Renal , Dispositivos de Acceso Vascular , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Politetrafluoroetileno , Diseño de Prótesis , Estudios Retrospectivos , Estados Unidos , Grado de Desobstrucción Vascular , Adulto Joven
12.
World J Surg ; 43(1): 273-281, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30128772

RESUMEN

BACKGROUND: Surgical decision making remains difficult in several patients with aneurysmal disease of the descending thoracic (DT) or thoracoabdominal (TA) aorta. Despite previous studies that have investigated aneurysms treated non-operatively using a prospective growth analysis, completeness and accuracy of follow-up were inconsistent. We aim to describe the survival and freedom from adverse aortic events in patients with DT and TA who did not undergo operative repair. METHODS: This is a single-center retrospective analysis of all patients with either a descending degenerative atherosclerotic or dissection-related DT or TA aortic lesion who were treated non-operatively from April 2002 to December 2016. We studied patients who did not undergo operative repair of descending degenerative atherosclerotic or dissection-related DT or TA aortic lesion. Primary end points were overall survival and freedom from aortic-related mortality (ARM). RESULTS: Of the 315 patients diagnosed with DT or TA disease, 56 (18%) did not undergo surgical repair. Mean aneurysm diameter was 65 mm ± 15 (range 50-120; IQR 5.4-7.15). Extent of the aortic aneurysms was DT in 36 (11%) patients and TA in 20 (6%). Median duration of follow-up was 12 months (range 1-108; IQR 3-36). Over the course of the study, 41 (73%) patients died for an overall survival rate of 53% ± 7 at 1 year (95% CI 40-65) and 23% ± 7 at 3 year (95% CI 17-42.5). Aortic-related mortality was 27% (n = 15), significantly higher in patients with aneurysms ≥ 60 mm [n = 13, (39%) vs. n = 2, (9%); P = 0.025; OR = 5.04]. Overall, estimated freedom from ARM was 81% ± 5.5 at 1 year (95% CI 68-89) and 66.5% ± 9 at 3 year (95% CI 48-81). Only TA extent was independently associated with freedom from ARM during the follow-up (P = 0.005; HR: 5.74; 95% CI 1.711-19.729). CONCLUSIONS: Thoracoabdominal extent of the aneurysmal aortic disease is the most important predictor of ARM in unrepaired DT or TA aortic diseases. Mortality from aortic-related events was significantly more premature than mortality from non-aortic-related mortality.


Asunto(s)
Aneurisma de la Aorta Torácica/mortalidad , Aneurisma de la Aorta Torácica/terapia , Anciano , Anciano de 80 o más Años , Disección Aórtica/mortalidad , Disección Aórtica/terapia , Aterosclerosis/complicaciones , Comorbilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
13.
BMC Bioinformatics ; 19(Suppl 10): 357, 2018 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-30367588

RESUMEN

BACKGROUND: In the clinical practice, the objective quantification of histological results is essential not only to define objective and well-established protocols for diagnosis, treatment, and assessment, but also to ameliorate disease comprehension. SOFTWARE: The software MIAQuant_Learn presented in this work segments, quantifies and analyzes markers in histochemical and immunohistochemical images obtained by different biological procedures and imaging tools. MIAQuant_Learn employs supervised learning techniques to customize the marker segmentation process with respect to any marker color appearance. Our software expresses the location of the segmented markers with respect to regions of interest by mean-distance histograms, which are numerically compared by measuring their intersection. When contiguous tissue sections stained by different markers are available, MIAQuant_Learn aligns them and overlaps the segmented markers in a unique image enabling a visual comparative analysis of the spatial distribution of each marker (markers' relative location). Additionally, it computes novel measures of markers' co-existence in tissue volumes depending on their density. CONCLUSIONS: Applications of MIAQuant_Learn in clinical research studies have proven its effectiveness as a fast and efficient tool for the automatic extraction, quantification and analysis of histological sections. It is robust with respect to several deficits caused by image acquisition systems and produces objective and reproducible results. Thanks to its flexibility, MIAQuant_Learn represents an important tool to be exploited in basic research where needs are constantly changing.


Asunto(s)
Algoritmos , Biología Computacional/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Coloración y Etiquetado , Biomarcadores de Tumor/metabolismo , Árboles de Decisión , Humanos , Inmunohistoquímica , Programas Informáticos , Máquina de Vectores de Soporte
14.
Eur J Vasc Endovasc Surg ; 55(5): 633-639, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29506942

RESUMEN

OBJECTIVES: Prevalence data on abdominal aortic aneurysm (AAA) in women, subjects younger than 65 years and in subgroups carrying specific risk factors are scarce. AAA prevalence was evaluated in an Italian population including women and younger subjects, stratifying for the presence of cardiovascular disease (CVD) risk factors and CVD risk score. MATERIALS AND METHODS: A population based cross-sectional study was conducted between 2013 and 2016. Men aged 50-75 and women aged 60-75 years, resident in the city of Varese (northern Italy), were randomly selected from the civil registry. A vascular surgeon performed an abdominal aortic ultrasound scan at four sites using the leading edge to leading edge method. CVD risk score was computed using the ESC-SCORE algorithm. The age and gender specific prevalence was estimated, stratifying by the presence of CVD and cardiovascular risk factors. RESULTS: Among the 3755 subjects with a valid ultrasound measurement, 63 subjects with an AAA were identified (5 referred for surgical intervention), among whom 34 were not previously known (30 men 1.3%, 95% CI 0.9-1.8; 4 women 0.3%, 95% CI 0.1-0.8). Considering age classes in men only, the highest prevalence of screen detected AAA was found in subjects aged 65-70 (1.2%; 95% CI 0.4-2.5) and 70-75 (2.5%; 95% CI 1.4-4.0) years. Among 65-75 year old men, the highest AAA prevalence was found in subjects with a previous myocardial infarction (MI 4.9%, 95% CI 2.0-9.9) and in ever-smokers reporting more than 15 pack years of smoking (4.1%, 95% CI 2.5-6.3). Among the younger subjects, those having an ESC-SCORE higher than 5% or a previous CVD (MI or stroke) showed a prevalence of 1.4% (95% CI 0.3-4.2; prevalence including subaneurysms 6.7%, 95% CI 3.7-11.0%). CONCLUSIONS: In the study population, both a general screening program in 65-75 year old men and an approach targeted to subgroups at higher risk merit evaluation in a cost-effectiveness study. In 50-64 year old men, strategies for population selection should consider CVD risk stratification tools.


Asunto(s)
Aneurisma de la Aorta Abdominal/epidemiología , Tamizaje Masivo , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Prevalencia , Medición de Riesgo , Factores de Riesgo , Fumar/epidemiología , Ultrasonografía
15.
Radiol Med ; 123(8): 638-642, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29654570

RESUMEN

AIM: To evaluate safety, technical and clinical success of embolization of type Ia endoleak (T1a EL) using ethylene-vinyl alcohol copolymer as embolic agent alone or in combination with other materials. MATERIALS AND METHODS: Five patients presented T1a EL after endovascular repair of aortic aneurysms (EVAR) with radiological evidence of expanding sac size; in particular, three had contained rupture. In one patient, proximal cuff insertion was previously performed, in three patients proximal cuff was urgently inserted but T1a EL persisted; one patient, previously treated with Ovation Abdominal Stent Graft System, was directly proposed for endovascular treatment. In all cases, endovascular embolization was successfully performed and the transfemoral approach was always chosen; in one case it failed and translumbar approach by direct puncture of the sac was required. Used embolization agents were glue, ethylene-vinyl alcohol copolymer (Onyx) and coils in three cases, n-butyl cyanoacrylate and Onyx in one case, Onyx and coils in the last case. RESULTS: Technical success rate was 100% as well as clinical success. No major or minor complication, including non-target embolization, was registered. Clinical success was 100% until today and the sac diameter remained stable in four patients and decreased in one. CONCLUSIONS: Onyx may be considered a suitable embolic agent in the treatment of patients with type Ia endoleaks after EVAR, after failure of conventional treatments such as prolonged balloon inflation of the aortic neck or deployment of large bare stent.


Asunto(s)
Embolización Terapéutica/métodos , Enbucrilato/uso terapéutico , Endofuga/terapia , Polivinilos/uso terapéutico , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Femenino , Humanos , Masculino , Stents , Resultado del Tratamiento
16.
Ann Vasc Surg ; 43: 249-257, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28389285

RESUMEN

BACKGROUND: To analyze the predictors and describe the outcomes of cross-clamp intolerance (CCI) and the results of the use of carotid endarterectomy (CEA) with shunting or a shift strategy to immediate carotid artery stenting (CAS) in this setting. METHODS: Between January 2008 and December 2015, 385 patients were elected for single-sided, isolated CEA under locoregional anesthesia. In case of CCI, CEA with shunt was used selectively, whereas indication to immediate conversion to CAS was the immediate onset and severe persistent deterioration of the neurologic status, and/or local technical difficulties to perform endarterectomy. Primary outcome was prevention of death and all early (<30 days) perioperative cerebrovascular events. RESULTS: We treated 169 (43.9%) symptomatic lesions; urgent (≤48 hours) intervention was performed in 85 (22.1%) cases. Carotid CCI occurred in 45 (11.7%) patients. CEA with shunt was used in 16, whereas CAS in 27 (7.0%, 2 refused further treatment). Multivariable analysis identified hypertension (odds ratio [OR]: 2.93, 95% confidence interval [CI]: 1.01-8.52; P = 0.049) and symptomatic lesions (OR: 2.34, 95% CI: 1.11-4.93; P = 0.025) as significant predictors of CCI. In-hospital mortality rate was 0.5%; none occurred in CCI group. Postoperative cerebrovascular event rate was 2.3% (n = 9). At multivariable analyses, only CCI (OR: 6.60, 95% CI: 1.65-26.36; P = 0.008) was significantly associated with postoperative cerebrovascular events, with no significant different clinical outcomes between CEA and CAS. CONCLUSIONS: Hypertension and symptomatic carotid stenosis were significant predictors of CCI, which was found to be predictive for postoperative cerebrovascular events. In selected patients with CCI, CAS had satisfactory, similar results of CEA.


Asunto(s)
Anestesia de Conducción , Estenosis Carotídea/cirugía , Circulación Cerebrovascular , Endarterectomía Carotidea , Anciano , Anciano de 80 o más Años , Anestesia de Conducción/efectos adversos , Anestesia de Conducción/mortalidad , Estenosis Carotídea/complicaciones , Estenosis Carotídea/mortalidad , Estenosis Carotídea/fisiopatología , Trastornos Cerebrovasculares/etiología , Trastornos Cerebrovasculares/fisiopatología , Distribución de Chi-Cuadrado , Constricción , Endarterectomía Carotidea/efectos adversos , Endarterectomía Carotidea/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Hipertensión/complicaciones , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
Radiol Med ; 122(1): 69-76, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27601144

RESUMEN

AIM: To evaluate the technical and clinical success, primary patency (PP) and complications of angioplasty performed with paclitaxel-coated balloon (PCBs) associated with cutting balloon and for the treatment of the outflow stenoses of failing hemodialysis arteriovenous shunt. MATERIAL AND METHODS: From September 2014 to September 2015, 50 patients with 66 stenoses were registered. Vascular accesses were autogenous (n = 20) and prosthetic (n = 30). Stenosis were documented during follow-up with routine echo-color Doppler, clinical evaluation and in the remaining incidentally during fistulography. Angioplasty was performed with cutting balloon and afterward with PCB. The mean follow-up time was 8 months (range 6-15 months). Technical success, clinical success, primary patency and complications were registered. RESULTS: Technical success was 100 %. Clinical success was 94.7 %. Primary patency rate was 87.7 %; in five patients, a significant re-stenosis (≥50 %) was registered. A residual asymptomatic stenosis (<30 %) was registered in four cases (7 %). No major complications were registered. CONCLUSIONS: A short-term patency benefit may be obtained including PCB in angioplasty treatment of failing hemodialysis arteriovenous shunts.


Asunto(s)
Angioplastia de Balón , Derivación Arteriovenosa Quirúrgica/efectos adversos , Oclusión de Injerto Vascular/terapia , Paclitaxel/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Terapia Combinada , Constricción Patológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diálisis Renal , Resultado del Tratamiento , Grado de Desobstrucción Vascular
19.
Radiol Med ; 121(6): 482-93, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26883231

RESUMEN

PURPOSE: We report our experience regarding use of Fluency stent graft (Bard, Murray Hill, NJ, USA) for the treatment of peripheral aneurysms, pseudoaneurysms, arteriovenous fistulae, dissections and arterial ruptures, lacerations or perforations. METHODS AND MATERIALS: This two-center study included 59 patients (40 M, 19 F) with a mean age of 64.37 years (range 20-91 years). In total 61 lesions were treated, so subdivided: 10 true aneurysms, 26 pseudoaneurysms, 5 iatrogenic arteriovenous fistulae, 20 arterial ruptures, lacerations or perforations. RESULTS: Immediate technical success was obtained in 60 of 61 lesions (98.3 %); in 1 case (pseudoaneurysm of hepatic artery) additional embolization of the gastroduodenal artery with microcoils was needed. Follow-up was available for 57 patients and 59 lesions; mean period was 23.52 months (range 1-60 months). At 1-year primary patency was 89.47 %, whereas secondary patency was 96.4 %. CONCLUSION: Endovascular application of Fluency stent graft seems to offer an effective, and durable less invasive alternative to standard surgical techniques for the treatment of peripheral aneurysms, pseudoaneurysms, iatrogenic arteriovenous fistulae and arterial ruptures, or penetrating injuries.


Asunto(s)
Prótesis Vascular , Stents , Enfermedades Vasculares/terapia , Adulto , Anciano , Anciano de 80 o más Años , Angiografía , Femenino , Humanos , Enfermedad Iatrogénica , Masculino , Persona de Mediana Edad , Politetrafluoroetileno , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía , Enfermedades Vasculares/diagnóstico por imagen , Grado de Desobstrucción Vascular
20.
Ann Vasc Surg ; 29(6): 1320.e11-5, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26080299

RESUMEN

The aim of this study is to report the use of thoracic endovascular aortic repair (TEVAR) in blunt thoracic aortic injuries (BTAIs) presenting with complex anatomies of the aortic arch vessels. Two patients were admitted to our hospital for the management of BTAI. Anomalies were as follow: aberrant right subclavian artery (n = 1) and right-sided aortic arch with 5 vessels anatomy variant (n = 1). TEVAR was accomplished using parallel graft with periscope configuration in the patient with the aberrant right subclavian artery. At 12-month follow-up, computed tomography angiographies confirmed the exclusion of the BTAI, the stability of the endograft, the resolution of the pseudoaneurysm, and the patency of the parallel endograft. Aortic arch vessels variants and anomalies are not rare, and should be recognized and studied precisely to plan the most appropriate operative treatment. TEVAR proved to be effective even in complex anatomies.


Asunto(s)
Aneurisma Falso/cirugía , Aneurisma , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular , Anomalías Cardiovasculares , Trastornos de Deglución , Procedimientos Endovasculares , Arteria Subclavia/anomalías , Lesiones del Sistema Vascular/cirugía , Heridas no Penetrantes/cirugía , Aneurisma/diagnóstico , Aneurisma Falso/diagnóstico , Aorta Torácica/anomalías , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/lesiones , Aneurisma de la Aorta Torácica/diagnóstico , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Anomalías Cardiovasculares/diagnóstico , Trastornos de Deglución/diagnóstico , Procedimientos Endovasculares/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico , Heridas no Penetrantes/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA