Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int J Hyperthermia ; 39(1): 1397-1407, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36351216

RESUMEN

PURPOSE: To characterize the coagulation zones created by two radiofrequency (RF)-based hemostatic devices: one comprised an internally cooled monopolar electrode and the other comprised externally irrigated bipolar electrodes (saline-linked). MATERIALS AND METHODS: RF-induced coagulation zones were created on ex vivo and in vivo porcine models. Computer modeling was used to determine the RF power distribution in the saline-linked device. RESULTS: Both external (irrigation) and internal cooling effectively prevented tissue sticking. Under ex vivo conditions in 'painting' application mode, coagulation depth increased with the applied power: 2.8 - 5.6 mm with the 3-mm monopolar electrode, 1.6 - 6.0 mm with the 5-mm monopolar electrode and 0.6 - 3.2 mm with the saline-linked bipolar electrodes. Under in vivo conditions and using spot applications, the 3-mm monopolar electrode created coagulation zones of similar depth to the saline-linked bipolar electrodes (around 3 mm), while the 5-mm monopolar electrode created deeper coagulations (4.5 - 6 mm) with less incidence of popping. The presence of saline around the saline-linked bipolar electrodes meant that a significant percentage of RF power (50 - 80%) was dissipated by heating in the saline layer. Coagulation zones were histologically similar for all the tested devices. CONCLUSIONS: Both external (irrigation) and internal cooling in hemostatic RF devices effectively prevent tissue sticking and create similar coagulation zones from a histological point of view. Overall, saline-linked bipolar electrodes tend to create shallower coagulations than those created with an internally cooled monopolar electrode.


Asunto(s)
Ablación por Catéter , Hemostáticos , Porcinos , Animales , Hígado/cirugía , Electrodos , Ondas de Radio , Solución Salina/uso terapéutico , Diseño de Equipo
2.
Int J Hyperthermia ; 38(1): 409-420, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33719808

RESUMEN

PURPOSE: To study the differences between continuous and short-pulse mode microwave ablation (MWA). METHODS: We built a computational model for MWA including a 200 mm long and 14 G antenna from Amica-Gen and solved an electromagnetic-thermal coupled problem using COMSOL Multiphysics. We compared the coagulation zone (CZ) sizes created with pulsed and continuous modes under ex vivo and in vivo conditions. The model was used to compare long vs. short pulses, and 1000 W high-powered short pulses. Ex vivo experiments were conducted to validate the model. RESULTS: The computational models predicted the axial diameter of the CZ with an error of 2-3% and overestimated the transverse diameter by 9-11%. For short pulses, the ex vivo computer modeling results showed a trend toward larger CZ when duty cycles decreases. In general, short pulsed mode yielded higher CZ diameters and volumes than continuous mode, but the differences were not significant (<5%), as in terms of CZ sphericity. The same trends were observed in the simulations mimicking in vivo conditions. Both CZ diameter and sphericity were similar with short and long pulses. Short 1000 W pulses produced smaller sphericity and similar CZ sizes under in vivo and ex vivo conditions. CONCLUSIONS: The characteristics of the CZ created by continuous and pulsed MWA show no significant differences from ex vivo experiments and computer simulations. The proposed idea of enlarging coagulation zones and improving their sphericity in pulsed mode was not evident in this study.


Asunto(s)
Técnicas de Ablación , Ablación por Catéter , Ablación por Radiofrecuencia , Simulación por Computador , Computadores , Hígado/cirugía , Microondas
3.
Int J Hyperthermia ; 37(1): 1131-1138, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32996794

RESUMEN

PURPOSE: To compare the size of the coagulation (CZ) and periablational (PZ) zones created with two commercially available devices in clinical use for radiofrequency (RFA) and microwave ablation (MWA), respectively. METHODS: Computer models were used to simulate RFA with a 3-cm Cool-tip applicator and MWA with an Amica-Gen applicator. The Arrhenius model was used to compute the damage index (Ω). CZ was considered when Ω > 4.6 (>99% of damaged cells). Regions with 0.6<Ω < 2.1 were considered as the PZ (tissue that has undergone moderate sub-ablative hyperthermia). The ratio of PZ volume to CZ volume (PZ/CZ) was regarded as a measure of performance, since a low value implies achieving a large CZ while keeping the PZ small. RESULTS: Ten-min RFA (51 W) created smaller periablational zones than 10-min MWA (11.3 cm3 vs. 17.2-22.9 cm3, for 60-100 W MWA, respectively). Prolonging duration from 5 to 10 min increased the PZ in MWA more than in RFA (2.7 cm3 for RFA vs. 8.3-11.9 cm3 for 60-100 W MWA, respectively). PZ/CZ for RFA were relatively high (65-69%), regardless of ablation time, while those for MWA were highly dependent on the duration (increase of up to 25% between 5 and 10 min) and on the applied power (smaller values as power was raised, 102% for 60 W vs. 81% for 100 W, both for 10 min). The lowest PZ/CZ across all settings was 56%, obtained with 100 W-5 min MWA. CONCLUSIONS: Although RFA creates smaller periablational zones than MWA, 100 W-5 min MWA provides the lowest PZ/CZ.


Asunto(s)
Ablación por Catéter , Hipertermia Inducida , Ablación por Radiofrecuencia , Computadores , Microondas
4.
Int J Hyperthermia ; 36(1): 677-686, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31317817

RESUMEN

Introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy.


Asunto(s)
Ablación por Catéter/métodos , Conductos Pancreáticos/cirugía , Animales , Catéteres , Bovinos , Impedancia Eléctrica , Diseño de Equipo , Hígado/cirugía , Porcinos
5.
Int J Hyperthermia ; 34(1): 112-121, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28540817

RESUMEN

BACKGROUND: The thermal and electrical effects of pulsed radiofrequency (PRF) for pain relief can be controlled by modifying the characteristics of the RF pulses applied. Our goal was to evaluate the influence of such modifications on the thermal and electric performance in tissue. METHODS: A computational model was developed to compare the temperature and electric field time courses in tissue between a standard clinical protocol (45 V pulses, 20 ms duration, 2 Hz repetition frequency) and a new protocol (55 V pulses, 5 ms duration, 5 Hz repetition frequency) with a higher applied electric field but a smaller impact on temperature alterations in tissue. The effect of including a temperature controller was assessed. Complementarily, an agar-based experimental model was developed to validate the methodology employed in the computer modelling. RESULTS: The new protocol increased the electric field magnitude reached in the tissue by around +20%, without increasing the temperature. The temperature controller was found to be the fundamental factor in avoiding thermal damage to the tissue and reduced the total number of pulses delivered by around 67%. The experimental results matched moderately well with those obtained from a computer model built especially to mimic the experimental conditions. CONCLUSIONS: For the same delivered energy, the new protocol significantly increases the magnitude of the applied electric field, which may be the reason why it is clinically more effective in achieving pain relief.


Asunto(s)
Dolor/radioterapia , Terapia por Radiofrecuencia , Simulación por Computador , Humanos , Modelos Teóricos , Temperatura
6.
Int J Hyperthermia ; 33(6): 624-634, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28540782

RESUMEN

PURPOSE: (1) To analyse rehydration, thermal convection and increased electrical conductivity as the three phenomena which distinguish the performance of internally cooled electrodes (IC) and internally cooled wet (ICW) electrodes during radiofrequency ablation (RFA), (2) Implement a RFA computer model with an ICW which includes these phenomena and (3) Assess their relative influence on the thermal and electrical tissue response and on the coagulation zone size. METHODS: A 12-min RFA in liver was modelled using an ICW electrode (17 G, 3 cm tip) by an impedance-control pulsing protocol with a constant current of 1.5 A. A model of an IC electrode was used to compare the ICW electrode performance and the computational results with the experimental results. RESULTS: Rehydration and increased electrical conductivity were responsible for an increase in coagulation zone size and a delay (or absence) in the occurrence of abrupt increases in electrical impedance (roll-off). While the increased electrical conductivity had a remarkable effect on enlarging the coagulation zone (an increase of 0.74 cm for differences in electrical conductivity of 0.31 S/m), rehydration considerably affected the delay in roll-off, which, in fact, was absent with a sufficiently high rehydration level. In contrast, thermal convection had an insignificant effect for the flow rates considered (0.05 and 1 mL/min). CONCLUSIONS: Computer results suggest that rehydration and increased electrical conductivity were mainly responsible for the absence of roll-off and increased size of the coagulation zone, respectively, and in combination allow the thermal and electrical performance of ICW electrodes to be modelled during RFA.


Asunto(s)
Técnicas de Ablación/instrumentación , Modelos Teóricos , Coagulación Sanguínea , Conductividad Eléctrica , Electrodos , Humanos , Hígado/cirugía , Equilibrio Hidroelectrolítico
7.
J Cardiovasc Electrophysiol ; 27(8): 947-52, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27138703

RESUMEN

INTRODUCTION: The outcomes of catheter ablation of scar-mediated ventricular tachycardia (VT) remain far from perfect. The presence of fat as a component of the underlying substrate for scar-mediated VT could be relevant since this entity can seriously impede the passage of RF current due to its low electrical conductivity. METHODS AND RESULTS: Computer models of RF ablation were built in order to investigate the means by which the spatial heterogeneity of different tissues represented within the ventricular infarct zone, including the viable myocardium, fibrous tissue, and fat, could influence temperature distributions during RF ablation. The results demonstrated that spatial distributions of different tissue types significantly alter the density of electrical current largely as a result of fat impeding the passage of current. However, the thermal lesions appear minimally unaffected by this phenomenon, with variations in depth of ∼1 mm. CONCLUSION: While during RF ablation of scar-related ventricular tachycardia differences in tissue characteristics may affect the density of electrical current on a small-scale, overall this does not appear to significantly impact the size of the created thermal lesions.


Asunto(s)
Tejido Adiposo/patología , Ablación por Catéter , Cicatriz/etiología , Modelos Cardiovasculares , Infarto del Miocardio/complicaciones , Miocardio/patología , Taquicardia Ventricular/cirugía , Potenciales de Acción , Tejido Adiposo/fisiopatología , Cicatriz/patología , Cicatriz/fisiopatología , Simulación por Computador , Conductividad Eléctrica , Fibrosis , Frecuencia Cardíaca , Humanos , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/patología , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
8.
Int J Hyperthermia ; 32(3): 221-30, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26862788

RESUMEN

PURPOSE: The aim was to study by computer simulations the insulating role of the reactive zone surrounding a cortical osteoid osteoma (OO) in terms of electrical and thermal performance during radiofrequency ablation (RFA). MATERIAL AND METHODS: We modelled a cortical OO consisting of a nidus (10 mm diameter) enclosed by a reactive zone. The OO was near a layer of cortical bone 1.5 mm thick. Trabecular bone partially surrounds the OO and there was muscle around the cortical bone layer. We modelled RF ablations with a non-cooled-tip 17-gauge needle electrode (300 s duration and 90 °C target temperature). Sensitivity analyses were conducted assuming a reactive zone electrical conductivity value (σrz) within the limits of the cortical and trabecular bone, i.e. 0.02 S/m and 0.087 S/m, respectively. In this way we were really modelling the different degrees of osteosclerosis associated with the reactive zone. RESULTS: The presence of the reactive zone drastically reduced the maximum temperature reached outside it. The temperature drop was proportional to the thickness of the reactive zone: from 68 °C when it was absent to 44 °C when it is 7.5 mm thick. Higher nidus conductivity values (σn) implied higher temperatures, while lower temperatures meant higher σrz values. Changing σrz from 0.02 S/m to 0.087 S/m reduced lesion diameters from 2.4 cm to 1.8 cm. CONCLUSIONS: The computer results suggest that the reactive zone plays the role of insulator in terms of reducing the temperature in the surrounding area.


Asunto(s)
Neoplasias Óseas/cirugía , Ablación por Catéter , Modelos Biológicos , Osteoma Osteoide/cirugía , Simulación por Computador , Hueso Cortical/fisiología , Conductividad Eléctrica , Electrodos , Temperatura , Conductividad Térmica
9.
Int J Hyperthermia ; 32(8): 931-939, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27452352

RESUMEN

PURPOSE: To develop computer models to mimic the impedance-controlled pulsing protocol implemented in radiofrequency (RF) generators used for clinical practice of radiofrequency ablation (RFA), and to assess the appropriateness of the models by comparing the computer results with those obtained in previous experimental studies. METHODS: A 12-min RFA was modelled using a cooled electrode (17G, 3 cm tip) inserted in hepatic tissue. The short (transverse) diameter of the coagulation zone was assessed under in vivo (with blood perfusion (BP) and considering clamping) and ex vivo (at 21 °C) conditions. The computer results obtained by programming voltage pulses were compared with current pulses. RESULTS: The differences between voltage and current pulses were noticeable: using current instead of voltage allows larger coagulation zones to be created, due to the higher energy applied by current pulses. If voltage pulses are employed the model can accurately predict the number of roll-offs, although the waveform of the applied power is clearly not realistic. If current voltages are employed, the applied power waveform matches well with those reported experimentally, but there are significantly fewer roll-offs. Our computer results were overall into the ranges of experimental ones. CONCLUSIONS: The proposed models reproduce reasonably well the electrical-thermal performance and coagulation zone size obtained during an impedance-controlled pulsing protocol.


Asunto(s)
Técnicas de Ablación/instrumentación , Impedancia Eléctrica , Modelos Teóricos , Neoplasias/cirugía , Sangre , Simulación por Computador , Electrodos , Humanos , Hígado , Ondas de Radio , Temperatura
10.
Biomed Eng Online ; 13: 164, 2014 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-25494912

RESUMEN

BACKGROUND: Externally irrigated radiofrequency (RF) electrodes have been widely used to thermally ablate tumors in surface tissue and to thermally coagulate the transection plane during a surgical resection. As far as we know, no mathematical model has yet been developed to study the electrical and thermal performance of these electrodes, especially the role of the saline layer that forms around the electrode. METHODS: Numerical models of a TissueLink device model DS3.0 (Salient Surgical Technologies, Portsmouth, NH, USA) were developed. Irrigation was modeled including a saline layer and a heat convection term in the governing equation. Ex vivo experiments based on fragments of bovine hepatic tissue were conducted to obtain information which was used in building the numerical model. We compared the 60°C isotherm of the computer results with the whitening contour in the heated samples. RESULTS: Computer and experimental results were in fine agreement in terms of lesion depth (2.4 mm in the simulations and 2.4 ± 0.6 mm in the experiments). In contrast, the lesion width was greater in the simulation (9.6 mm vs. 7.8 ± 1.8 mm). The computer simulations allowed us to explain the role of the saline layer in creating the thermal lesion. Impedance gradually decreased as heating proceeded. The saline was not observed to boil. In the proximity of the electrode (around 1 mm) the thermal lesion was mainly created by the RF power in this zone, while at a further distance the thermal lesion was created by the hot saline on the tissue surface by simple thermal conduction. Including the heat convection term associated with the saline velocity in the governing equation was crucial to verifying that the saline layer had not reached boiling temperature. CONCLUSIONS: The model reproduced thermal performance during heating in terms of lesion depth, and provided an explanation for: 1) the relationship between impedance, electrode insertion depth, and saline layer, and 2) the process of creating thermal lesions in the tissue with this type of electrode.


Asunto(s)
Electrodos , Neoplasias/terapia , Sales (Química)/química , Algoritmos , Animales , Bovinos , Simulación por Computador , Impedancia Eléctrica , Calor , Modelos Cardiovasculares , Modelos Teóricos , Ondas de Radio , Procesamiento de Señales Asistido por Computador , Programas Informáticos
11.
Int J Hyperthermia ; 30(6): 372-84, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25256891

RESUMEN

PURPOSE: The aim of this study was to compare the efficacy of bipolar (BM) vs. unipolar (UM) mode of radiofrequency ablation (RFA) in terms of creating transmural lesions across the interventricular septum (IVS) and ventricular free wall (VFW). MATERIALS AND METHODS: We built computational models to study the temperature distributions and lesion dimensions created by BM and UM on IVS and VFW during RFA. Two different UM types were considered: sequential (SeUM) and simultaneous (SiUM). The effect of ventricular wall thickness, catheter misalignment, epicardial fat, and presence of air in the epicardial space were also studied. RESULTS: Regarding IVS ablation, BM created transmural and symmetrical lesions for wall thicknesses up to 15 mm. SeUM and SiUM were not able to create transmural lesions with IVS thicknesses ≥12.5 and 15 mm, respectively. Lesions were asymmetrical only with SeUM. For VFW ablation, BM also created transmural lesions for wall thicknesses up to 15 mm. However, with SeUM and SiUM transmurality was obtained for VFW thicknesses ≤7.5 and 12.5 mm, respectively. With the three modes, VFW lesions were always asymmetrical. In the scenario with air or a fat tissue layer on the epicardial side, only SiUM was capable of creating transmural lesions. Overall, BM was superior to UM in IVS and VFW ablation when the catheters were not aligned. CONCLUSIONS: Our findings suggest that BM is more effective than UM in achieving transmurality across both ventricular sites, except in the situation of the epicardial catheter tip surrounded by air or placed over a fat tissue layer.


Asunto(s)
Ablación por Catéter/métodos , Ventrículos Cardíacos/cirugía , Modelos Teóricos , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Electrodos
12.
Int J Hyperthermia ; 29(6): 590-7, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23841882

RESUMEN

PURPOSE: Although theoretical modelling is widely used to study different aspects of radiofrequency ablation (RFA), its utility is directly related to its realism. An important factor in this realism is the use of mathematical functions to model the temperature dependence of thermal (k) and electrical (σ) conductivities of tissue. Our aim was to review the piecewise mathematical functions most commonly used for modelling the temperature dependence of k and σ in RFA computational modelling. MATERIALS AND METHODS: We built a hepatic RFA theoretical model of a cooled electrode and compared lesion dimensions and impedance evolution with combinations of mathematical functions proposed in previous studies. We employed the thermal damage contour D63 to compute the lesion dimension contour, which corresponds to Ω = 1, Ω being local thermal damage assessed by the Arrhenius damage model. RESULTS: The results were very similar in all cases in terms of impedance evolution and lesion size after 6 min of ablation. Although the relative differences between cases in terms of time to first roll-off (abrupt increase in impedance) were as much as 12%, the maximum relative differences in terms of the short lesion (transverse) diameter were below 3.5%. CONCLUSIONS: The findings suggest that the different methods of modelling temperature dependence of k and σ reported in the literature do not significantly affect the computed lesion diameter.


Asunto(s)
Ablación por Catéter , Modelos Teóricos , Conductividad Eléctrica , Temperatura , Conductividad Térmica
13.
Int J Hyperthermia ; 29(3): 211-8, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23573935

RESUMEN

PURPOSE: The aim of this study was to assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA. MATERIALS AND METHODS: A modelling study and in vivo experimental study were used. A Cool-tip RF applicator was used both for EP and RFA. RESULTS: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode. CONCLUSIONS: Our computer modelling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone.


Asunto(s)
Ablación por Catéter , Electroporación , Modelos Teóricos , Animales , Terapia Combinada , Simulación por Computador , Estudios de Factibilidad , Femenino , Hígado/cirugía , Porcinos
14.
Int J Hyperthermia ; 28(1): 62-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22235786

RESUMEN

PURPOSE: To study the relationship between roll-off (sudden increase in impedance) and spatial distribution of dehydrated tissue during RF ablation using a cooled electrode (temperatures around 100°C). METHODS: We used a double approach: (1) theoretical modelling based on the finite element method, and (2) 20 ablations using an experimental study on ex vivo excised bovine liver in which we measured impedance progress and temperature at three points close to the electrode surface: 0.5 (T1), 1.5 (T2) and 2.5 (T3) mm from the tip. T2 was located exactly at the centre of the 30 mm long electrode. RESULTS: Temperatures at T1 and T3 quickly rose to 100°C (at ≈20 and 40 s, respectively), while at the rise at T2 was somewhat slower, stabilized around 50 s and reached a maximum value of 99°C at about 60 s. Impedance reached a minimum of 65 Ω (plateau), began increasing at 50 s and continued rising throughout the procedure, reaching a value equal to the initial value at 70 s. Likewise, computed impedance dropped to ≈73 Ω (plateau), began increasing at 50 s and reached an impedance value equal to the initial value at ≈78 s, which approximately coincided with the time when the entire zone surrounding the electrode was within the 100°C isotherm. CONCLUSION: There is a close relationship between the moment at which roll-off occurs and the time when the entire electrode is completely encircled by the dehydrated tissue. The mid-electrode zone is the last in which tissue desiccation occurs.


Asunto(s)
Ablación por Catéter/instrumentación , Desecación , Hígado/cirugía , Animales , Bovinos , Conductividad Eléctrica , Electrodos , Hígado/patología , Modelos Teóricos , Temperatura
15.
Int J Hyperthermia ; 28(7): 663-73, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22974100

RESUMEN

PURPOSE: To study the capacity of an internally cooled radiofrequency (RF) bipolar applicator to create sufficiently deep thermal lesions in hepatic tissue. MATERIALS AND METHODS: Three complementary methodologies were employed to check the electrical and thermal behaviour of the applicator under test. The experimental studies were based on excised bovine (ex vivo study) and porcine liver (in vivo study) and the theoretical models were solved by means of the finite element method (FEM). RESULTS: Experimental and computational results showed good agreement in terms of impedance progress and lesion depth (4 and 4.5 mm respectively for ex vivo conditions, and ≈7 and 9 mm respectively for in vivo conditions), although the lesion widths were overestimated by the computer simulations. This could have been due to the method used to assess the thermal lesions; the experimental lesions were assessed by the white coagulation zone, whereas the tissue damage function was used to assess the computational lesions. CONCLUSIONS: The experimental results suggest that this applicator could create in vivo lesions to a depth of around 7 mm. It was also observed that the thermal lesion is mainly confined to the area between both electrodes, which would allow lesion width to be controlled by selecting a specific applicator design. The comparison between the experimental and computational results suggests that the theoretical model could be usefully applied in further studies of the performance of this device.


Asunto(s)
Electrocoagulación/instrumentación , Hígado/cirugía , Animales , Bovinos , Simulación por Computador , Electrocoagulación/métodos , Electrodos , Estudios de Factibilidad , Modelos Teóricos , Porcinos , Temperatura
16.
Comput Methods Programs Biomed ; 214: 106569, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34906785

RESUMEN

BACKGROUND AND OBJECTIVES: Thermal ablation of tumors plays a key role to fight cancer, since it is a minimally invasive treatment which involves some advantages compared to surgery and chemotherapy, such as shorter hospital stays and consequently lower costs, along with minor side effects. In this context, computational modeling of heat transfer during thermal ablation is relevant to accurately predict the obtained ablation zone in order to avoid tumor recurrence risk caused by incomplete ablation, and the same time to save the surrounding healthy tissue. The aim of this work is to develop a more realistic porous media-based mathematical model to simulate a microwave thermal ablation (MWA) of an in vivo liver tumor surrounded by healthy tissue. METHODS: The domain is made up of a spherical tumor bounded by a cylindrical healthy liver tissue. The simulated microwave antenna is a 14 G HS Amica-Gen Probe, and the supplied power of 60 W is applied for 300 s and 600 s. The model consists in coupling modified Local Thermal Non Equilibrium (LTNE) equations with the electromagnetic equations. The LTNE equations include a variable porosity function which fits the porosity changing from the tumor core to the rim based on experimental measures in in vivo cases. Moreover, four different blood vessels' uniform distributions are investigated to compare the effects of different vascularizations of the considered target tissue. RESULTS: The results are shown in terms of temperature fields, ablation diameters and volumes based on the Arrhenius thermal damage model with 99% of cell death probability. The outcomes show a very good agreement with a clinical study on human patients with hepatocellular carcinoma using the same antenna and energy setting, when terminal arteries distribution is included. CONCLUSIONS: In this work, an in vivo microwave ablation of liver tumor surrounded by healthy tissue is modeled with a variable-porosity medium approach based on experimental measures. The outcomes shown for distinct vascularizations underline the key relevance of modeling more and more accurately tumor MWA, by considering increasingly realistic features, avoiding tumor recurrence, and improving both medical protocols and devices.


Asunto(s)
Técnicas de Ablación , Ablación por Catéter , Neoplasias Hepáticas , Humanos , Hígado/diagnóstico por imagen , Hígado/cirugía , Neoplasias Hepáticas/cirugía , Microondas , Modelos Teóricos , Recurrencia Local de Neoplasia , Porosidad
17.
Comput Methods Programs Biomed ; 221: 106896, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35617809

RESUMEN

BACKGROUND AND OBJECTIVE: In the last few years, we have been exploring the use of transparent nanocrystalline yttria-stabilized zirconia (nc-YSZ) ceramics as a biomedical transparent cranial implant, referred as the "Window to the Brain" (WttB). The WttB aims at providing chronical optical access to the brain for diagnostics and therapeutic procedures and it has shown to provide an effective means to obtain enhanced results from optical imaging techniques. The objective of this work is to explore the photothermal effects of the Wttb produced when it is irradiated by a laser source. METHODS: We make experimental and computer models. The thermal effects of laser irradiation on the nc-YSZ samples were evaluated upon registering the induced temperature changes by means of thermal imaging. The computer models try to mimic the experimental models using a similar geometry, reproducing the physical situation by a couple thermal-optical problem and adjusting the main parameters from the experimental results. RESULTS: Experimental and computational coincides in results: Temperatures at the bottom surface of the implant does not exceed those which produce thermal damage. The quantitative comparison between experimental and computational models show that differences in results are under a reasonable value of 5% and qualitatively we observe a similar behavior. The results provide optimum values for the thermal-optical nc-YSZ parameters considering a linear and exponential relationship with temperature for the absorption coefficient: The thermal conductivity is k = 2.13 W/m·K and the absorption coefficient α varies from 426 to 526 m-1 with the linear relationship, and k = 2.04 W/m·K and α ∈ [433,502] m-1 with the exponential. The reflection coefficient is R = 19% in both cases. CONCLUSIONS: The temperatures achieved in the nc-YSZ during the laser irradiation are suitable for biomedical applications. The combination of experimental and computational models contributes to build a clinically oriented model with the thermal-optical parameters values stablished and to determine their influence in results. Specifically, the absorption coefficient of the nc-YSZ samples is the most influent parameter in the obtained temperatures. Moreover, this combination provides a method to evaluate the relevant thermal-optical parameters of nc-YSZ samples obtained with different manufacturing processes.


Asunto(s)
Itrio , Circonio , Simulación por Computador , Itrio/química , Circonio/química
18.
Sci Rep ; 12(1): 316, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-35013377

RESUMEN

Microwave (MWA) and radiofrequency ablation (RFA) are main ablative techniques for hepatocellular carcinoma (HCC) and colorectal liver metastasis (MT). This randomized phase 2 clinical trial compares the effectiveness of MWA and RFA as well as morphology of corresponding ablation zones. HCC and MT patients with 1.5-4 cm tumors, suitable for ablation, were randomized into MWA or RFA Groups. The primary endpoint was short-to-long diameter ratio of ablation zone (SLR). Primary technical success (TS) and a cumulative local tumor progression (LTP) after a median 2-year follow-up were compared. Between June 2015 and April 2020, 82 patients were randomly assigned (41 patients per group). For the per-protocol analysis, five patients were excluded. MWA created larger ablation zones than RFA (p = 0.036) although without differences in SLR (0.5 for both groups, p = 0.229). The TS was achieved in 98% (46/47) and 90% (45/50) (p = 0.108), and LTP was observed in 21% (10/47) vs. 12% (6/50) (OR 1.9 [95% CI 0.66-5.3], p = 0.238) of tumors in MWA vs. RFA Group, respectively. Major complications were found in 5 cases (11%) vs. 2 cases (4%), without statistical significance. MWA and RFA show similar SLR, effectiveness and safety in liver tumors between 1.5 and 4 cm.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Neoplasias Colorrectales/patología , Neoplasias Hepáticas/cirugía , Microondas/uso terapéutico , Ablación por Radiofrecuencia , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Masculino , Microondas/efectos adversos , Persona de Mediana Edad , Estudios Prospectivos , Ablación por Radiofrecuencia/efectos adversos , Método Simple Ciego , España , Factores de Tiempo , Resultado del Tratamiento , Carga Tumoral
19.
Int J Hyperthermia ; 27(6): 539-48, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21846190

RESUMEN

PURPOSE: To assess whether tailoring the Kp and Ki values of a proportional-integral (PI) controller during radiofrequency (RF) cardiac ablation could be advantageous from the point of view of the dynamic behaviour of the controller, in particular, whether control action could be speeded up and larger lesions obtained. METHODS: Theoretical models were built and solved by the finite element method. RF cardiac ablations were simulated with temperature controlled at 55°C. Specific PI controllers were implemented with Kp and Ki parameters adapted to cases with different tissue values (specific heat, thermal conductivity and electrical conductivity) electrode-tissue contact characteristics (insertion depth, cooling effect of circulating blood) and electrode characteristics (size, location and arrangement of the temperature sensor in the electrode). RESULTS: The lesion dimensions and T(max) remained almost unchanged when the specific PI controller was used instead of one tuned for the standard case: T(max) varied less than 1.9°C, lesion width less than 0.2 mm, and lesion depth less than 0.3 mm. As expected, we did observe a direct logical relationship between the response time of each controller and the transient value of electrode temperature. CONCLUSION: The results suggest that a PI controller designed for a standard case (such as that described in this study), could offer benefits under different tissue conditions, electrode-tissue contact, and electrode characteristics.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Ablación por Catéter/métodos , Temperatura , Conductividad Eléctrica , Electrodos , Estudios de Factibilidad , Análisis de Elementos Finitos , Corazón , Modelos Teóricos , Conductividad Térmica
20.
Sci Rep ; 11(1): 5272, 2021 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-33674658

RESUMEN

The objective of this study was to compare three different heat transfer models for radiofrequency ablation of in vivo liver tissue using a cooled electrode and three different voltage levels. The comparison was between the simplest but less realistic Pennes' equation and two porous media-based models, i.e. the Local Thermal Non-Equilibrium (LTNE) equations and Local Thermal Equilibrium (LTE) equation, both modified to take into account two-phase water vaporization (tissue and blood). Different blood volume fractions in liver were considered and the blood velocity was modeled to simulate a vascular network. Governing equations with the appropriate boundary conditions were solved with Comsol Multiphysics finite-element code. The results in terms of coagulation transverse diameters and temperature distributions at the end of the application showed significant differences, especially between Pennes and the modified LTNE and LTE models. The new modified porous media-based models covered the ranges found in the few in vivo experimental studies in the literature and they were closer to the published results with similar in vivo protocol. The outcomes highlight the importance of considering the three models in the future in order to improve thermal ablation protocols and devices and adapt the model to different organs and patient profiles.


Asunto(s)
Simulación por Computador , Calor , Circulación Hepática/efectos de la radiación , Hígado/irrigación sanguínea , Hígado/cirugía , Modelos Biológicos , Ablación por Radiofrecuencia/métodos , Coagulación Sanguínea/efectos de la radiación , Velocidad del Flujo Sanguíneo , Humanos , Hígado/efectos de la radiación , Neoplasias Hepáticas/cirugía , Porosidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA