Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Mol Imaging Biol ; 6(3): 131-8, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15193247

RESUMEN

PURPOSE: Coronary angiography defines geometry of lumen of artery. However, perhaps 70% of heart attacks occur when minimally obstructive thin capped fibroatheroma rupture, causing thrombus and arterial occlusion. We have developed an intravascular imaging detector to identify vulnerable coronary artery plaque. PROCEDURE: Detector measures beta or conversion electron emissions from plaque-binding radiotracers. Detector assembly fits into a 2-mm diameter catheter and overcomes technical constraints of size, sensitivity, and conformance to intravascular environment. RESULTS: Device was tested by stepping test point sources past detector to verify function. System resolution is 6.7 mm and sensitivity is 400 cps/microCi one mm from detector. CONCLUSION: This prototype is a first step in imaging of labeled vulnerable plaque in coronary arteries. This type of system may assist in development of targeted and cost effective therapies to lower incidence of acute coronary artery diseases (CAD) such as unstable angina, acute myocardial infarction, and sudden cardiac death.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Partículas beta , Enfermedad de la Arteria Coronaria/terapia , Humanos , Trazadores Radiactivos , Cintigrafía
2.
Catheter Cardiovasc Interv ; 62(2): 221-9, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15170716

RESUMEN

Temperature heterogeneity along the inner surface of an artery may be a surrogate marker of impending plaque rupture and has been associated with an increased likelihood of future coronary events. Initial studies using catheter-based thermographic devices have demonstrated that the changes in temperature are subtle, while the effects of coronary flow on measured temperature have not yet been examined. A novel guidewire-based system (ThermoCoil, Imetrx) designed to measure surface temperature in coronary arteries was used to study the effects of heat source intensity and flow on measured temperature. An in vitro model of a focal, eccentric, heat-generating lesion demonstrated that a guidewire-based system can detect changes in surface temperature with a precision of less than 0.08 degrees C. In this model, temperature measurements increased linearly with source temperature and decreased with increases in flow by an exponent of -0.33 (P < 0.001 for both). Flow rates and heat source properties can significantly influence the measurement and interpretation of thermographic data. The incorporation of 2D thermographic images may contribute further to the characterization of metabolically active plaques likely to cause acute coronary syndromes.


Asunto(s)
Mapeo del Potencial de Superficie Corporal , Enfermedad de la Arteria Coronaria/diagnóstico , Termografía/instrumentación , Inteligencia Artificial , Velocidad del Flujo Sanguíneo/fisiología , Sistemas de Computación , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria/fisiología , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA