Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am Heart J ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

3.
Catheter Cardiovasc Interv ; 99(4): 1277-1286, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34939726

RESUMEN

OBJECTIVES: To evaluate the prognostic impact of baseline tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio, as an expression of the right ventricle-pulmonary artery (RV-PA) coupling, in patients with mitral regurgitation (MR) treated with the MitraClip. BACKGROUND: Impaired RV to PA coupling is considered a marker of RV dysfunction. METHODS: From February 2016 to February 2020, a total of 165 patients were evaluated and stratified in two groups according to a prespecified value of TAPSE/PASP ratio ≤ 0.36. RESULTS: The median patients' age was 79 (men: 62.4%). Sixty-three patients (38.1%) presented TAPSE/PASP ≤ 0.36 and were then compared with patients with TAPSE/PASP > 0.36. Functional MR etiology was more frequent in TAPSE/PASP ≤ 0.36 (71.4%; p = 0.046). Acute technical success was achieved in 92.7% of the population, without any significant difference between the two groups of study and with sustained results at 30-day (device success: 85.5%; procedural success: 84.8%). On multivariate Cox regression analysis, after correction for body mass index, chronic kidney disease and left ventricle ejection fraction ≥30% but <50%, TAPSE/PASP ≤ 0.36 remained a sustained predictor of mortality and hospitalization for heart failure at one year after MitraClip (hazard ratio: 3.87; 95% confidence interval: 1.83-8.22; p ≤ 0.001). Kaplan-Meier all-cause mortality and heart failure hospitalization rates at one year were consequently higher in patients with TAPSE/PASP ≤ 0.36 (39.4% vs. 14.8%; log-rank p ≤ 0.001). CONCLUSION: Baseline TAPSE/PASP ratio seems independently associated with all-cause mortality and heart failure hospitalization after MitraClip both in functional and degenerative MR.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Derecha , Ventrículos Cardíacos , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Pronóstico , Arteria Pulmonar/diagnóstico por imagen , Resultado del Tratamiento , Función Ventricular Derecha
4.
Catheter Cardiovasc Interv ; 97(1): E135-E145, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32400068

RESUMEN

OBJECTIVES: To investigate paravalvular leak (PVL) and devices success rates according to aortic angle (AA) in patients undergoing transcatheter aortic valve implantation (TAVI) with three new-generation self-expanding devices. BACKGROUND: The impact of aortic angle (AA) on TAVI device success and PVL rates is controversial. METHODS: This retrospective study included 392 patients submitted to TAVI for severe aortic stenosis with Portico, Evolut-R and Acurate-NEO, and available AA measurements at computed tomography (CT) angiography. AA was calculated from the implantation projection and was defined as the angle between the plane of aortic annulus and an ideal horizontal plane. Aorta was defined horizontal if AA>57° (75th percentile). RESULTS: In the horizontal group, the rates of moderate/severe PVL was higher in the Evolut-R group (20.8%), which was also characterized by a lower implant compared to that of Acurate-NEO, whereas device success was comparable among the three devices. AA was a significant predictor of moderate/severe PVLs (AUC 0.72, p = .002) only in the Evolut-R population. On multivariate analysis, calcium volume 850HU, bicuspid aortic valve, and implantation depth at the level of left coronary cusp were independent predictors of moderate/severe PVL. On univariate analysis in the horizontal aorta population, implantation depth was confirmed among the most significant predictors of moderate/severe PVL. CONCLUSIONS: Despite comparable device success rates, horizontal aorta represented a technical challenge only in the Evolut-R subgroup, which showed higher rates of moderate/severe PVL than Portico and Acurate-NEO, and was associated with a low implant.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Aorta , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Complicaciones Posoperatorias , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Echocardiography ; 38(11): 1913-1923, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34755379

RESUMEN

BACKGROUND: Mitral valve (MV) repair with MitraClip system is a safe treatment option for high-risk patients with significant mitral regurgitation (MR). We aimed to characterize, by three-dimensional echocardiography (3D-E), changes occurring in MV after implantation of third generation MitraClip XTR device, with specific reference to the underlying MR mechanism (functional vs degenerative, FMR vs DMR). METHODS: We prospectively enrolled 59 patients, who underwent intra-procedural 3D-E before and after device deployment. Three-D datasets were analyzed off-line, using a dedicated semiautomatic software, to obtain parametric quantification of mitral anatomy. RESULTS: Post-procedural MR of mild or lesser degree was achieved in 40 patients (68%), with no differences between FMR and DMR (p 0.9). After MitraClip XTR implantation, the FMR group experienced an immediate annular resizing, with reduction of antero-posterior diameter (p 0.024) and sphericity index (p 0.017), next to a recovery of physiological saddle-shape, defined by lower non-planar angle (p ≤0.001) and higher annulus height to commissural width ratio (p ≤0.001). On the opposite, the DMR group revealed a significant decrease of maximum annular velocity (p 0.027), addressing a mechanic effect of the device deployment. Finally, baseline anterior mitral leaflet angle was found as an independent predictor of acute procedural result (OR 6.7, [CI 1.01-44.33], p 0.049). CONCLUSIONS: MitraClip XTR implantation acts in restoring the original mitral geometry, with distinctive effects according to MR mechanism. Three-D parametric quantification of MV sheds new light on changes occurring in the valvular apparatus, and helps identifying possible new predictors of acute procedural success.


Asunto(s)
Ecocardiografía Tridimensional , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Ecocardiografía Transesofágica , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
6.
Echocardiography ; 37(8): 1213-1221, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32762102

RESUMEN

OBJECTIVES: To analyze left ventricular (LV) myocardial deformation and contractile reserve (CR) in asymptomatic patients with severe aortic regurgitation (AR) at rest and during exercise, and their correlation with functional capacity. BACKGROUND: The natural history of chronic AR is characterized by a prolonged silent phase before onset of symptoms and overt LV dysfunction. Assessment of LV systolic function and contractile reserve has an important role in the decision-making of AR asymptomatic patients. METHODS: Standard echo, lung ultrasound, and LV 2D speckle tracking strain were performed at rest and during exercise in asymptomatic patients with severe AR and in age- and sex-comparable healthy controls. RESULTS: 115 AR patients (male sex 58.2%; 52.3 ± 18.3 years) and 55 controls were enrolled. Baseline LV ejection fraction was comparable between the groups. Resting LV global longitudinal strain (GLS) and myocardial work efficiency (MWE) were significantly reduced in AR (GLS-15.8 ± 2.8 vs -21.4 ± 4.4; P < .001). Patients with AR and CR- showed reduced resting LV GLS and MWE and increased B-lines. MWE was closely related to peak effort watts, VO2 , LV E/e', and B-lines, at a multivariable analysis. Both GLS and MWE were strong independent predictors of CR. A resting LV GLS cutoff of -12% differentiated CR+ and CR- (78% sensitivity and 84% specificity). CONCLUSIONS: The lower resting values of LV GLS and MWE in severe AR asymptomatic patients suggest an early subclinical myocardial damage that seems to be closely associated with lower exercise capacity, greater pulmonary congestion, and blunted LV contractile reserve during stress.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Disfunción Ventricular Izquierda , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía de Estrés , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
7.
Catheter Cardiovasc Interv ; 90(7): 1206-1211, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28145039

RESUMEN

OBJECTIVES: We report procedural and 30-day clinical outcomes following transcatheter aortic valve replacement (TAVR) with Lotus Valve system in a high-risk population. BACKGROUND: Lotus valve is a second-generation TAVR fully repositionable and retrievable device. RELEVANT (REgistry of Lotus valvE for treatment of aortic VAlve steNosis with Tavr) study is an Italian prospective multicentre registry. METHODS: Five major centers performing TAVR using Lotus participated. All high-risk symptomatic patients with severe aortic stenosis were evaluated by a heart team and screened for eligibility for TAVR. Primary end-points were procedural and 30-day mortality. Secondary endpoints included procedural and 30-day safety/effectiveness metrics according to Valve Academic Research Consortium (VARC)-2 criteria. RESULTS: Two hundred and twenty-five patients undergoing TAVR with Lotus were enrolled. Mean age was 82.6 ± 6.3 years, 51.6% females. Mean STS score for mortality was 8.3 ± 5.6. Procedural success was achieved in 98.7% of patients. All-cause mortality was 2.2% at discharge and 2.7% at 30-day. Stroke rate was 2.2% at discharge and 3.1% at 30-day. Patients requiring a new permanent pacemaker implantation were 30.7% at discharge and 31.8% at 30-day. Paravalvular regurgitation (PVR) was trace/mild in 99.1% of patients at discharge. Only two patients (0.9%) had moderate PVR at discharge and at 30-day, whereas none had severe PVR. CONCLUSIONS: RELEVANT study showed that TAVR using Lotus, in a real-world population of patients with severe aortic stenosis at high surgical risk, was associated with excellent device success implantation and early safety according to VARC-2 definition. The pacemaker implantation rate was about a third of patients. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Ecocardiografía , Femenino , Hemodinámica , Humanos , Italia , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
8.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-38710782

RESUMEN

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X , Aorta/diagnóstico por imagen , Aorta/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas , Estudios Retrospectivos
9.
EuroIntervention ; 18(17): 1408-1417, 2023 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-36809256

RESUMEN

BACKGROUND: A risk score was recently derived from the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) Trial. However, external validation of this score is still lacking. AIMS: We aimed to validate the COAPT risk score in a large multicentre population undergoing mitral transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR). METHODS: The Italian Society of Interventional Cardiology (GIse) Registry of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO) population was stratified according to COAPT score quartiles. The performance of the COAPT score for 2-year all-cause death or heart failure (HF) hospitalisation was evaluated in the overall population and in patients with or without a COAPT-like profile. RESULTS: Among the 1,659 patients included in the GIOTTO registry, 934 had SMR and complete data for a COAPT risk score calculation. The incidence of 2-year all-cause death or HF hospitalisation progressively increased through the COAPT score quartiles in the overall population (26.4% vs 44.5% vs 49.4% vs 59.7%; log-rank p<0.001) and COAPT-like patients (24.7% vs 32.4% vs 52.3% vs. 53.4%; log-rank p=0.004), but not in those with a non-COAPT-like profile. The COAPT risk score had poor discrimination and good calibration in the overall population, moderate discrimination and good calibration in COAPT-like patients and very poor discrimination and poor calibration in non-COAPT-like patients. CONCLUSIONS: The COAPT risk score has a poor performance in the prognostic stratification of real-world patients undergoing M-TEER. However, after application to patients with a COAPT-like profile, moderate discrimination and good calibration were observed.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Factores de Riesgo , Hospitalización , Resultado del Tratamiento
10.
Am J Cardiol ; 200: 178-187, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37331223

RESUMEN

Despite the growing experience with MitraClip in the broad spectrum of mitral regurgitation (MR), limited data are available regarding the independent prognostic role on survival of different mitral regurgitation etiology subtypes. We sought to evaluate the impact of flail leaflet etiology in a large series of patients with primary MR (PMR) who underwent MitraClip treatment. The study included 588 patients with significant PMR from the multicenter GIOTTO (Italian Society of Interventional Cardiology [GIse] registry Of Transcatheter treatment of mitral valve regurgitaTiOn), stratified into 2 groups according to MR etiology: flail+ (n = 300) and flail- (n = 288). The primary end point was a composite of cardiac death and first rehospitalization for heart failure (HF). To account for the baseline differences, patients were propensity score-matched 1:1. Flail leaflet etiology was present in about a half of the patients. Acute technical success was achieved in 98% of the overall cohort, with no significant differences between the study groups (p = 0.789). At the 2-year Kaplan-Meier analysis, the primary end point occurred in 13% of flail+ patients compared with 23% in flail- (p = 0.009). The flail+ group presented lower rates of both cardiac death and rehospitalization for HF, whereas a similar overall death rate was observed between the groups. A multivariate Cox regression analysis identified flail leaflet etiology as an independent predictor of favorable outcome in terms of the primary end point (hazard ratio 0.141, 95% confidence interval 0.049 to 0.401, p <0.001). After propensity score matching, flail+ patients had confirmed lower rates of cardiac mortality and rehospitalization for HF but similar rates of overall death. In conclusion, flail leaflet-related etiology was common in patients with PMR who underwent MitraClip treatment and was an independent predictor of midterm favorable clinical outcomes.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Pronóstico , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Insuficiencia Cardíaca/complicaciones , Muerte , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
11.
EuroIntervention ; 19(11): e926-e936, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-37946539

RESUMEN

BACKGROUND: In the context of primary mitral regurgitation (PMR), the selection of patients for transcatheter edge-to-edge repair (TEER) does not include a systematic assessment of PMR-associated cardiac remodelling. AIMS: We aimed to investigate the epidemiology and prognostic significance of different phenotypes of extra-mitral valve (MV) cardiac involvement in a large series of patients with PMR referred for TEER. METHODS: The study included 654 patients from the multicentre Italian GIOTTO registry, stratified into groups according to extra-mitral valve (MV) cardiac involvement. The primary endpoint was all-cause death at 2-year follow-up. RESULTS: Patients with no cardiac involvement (NI; n=58), left heart involvement (LHI; n=343) and right heart involvement (RHI; n=253) were analysed. Acute technical success was achieved in 98% of patients. Kaplan-Meier curve analysis revealed significantly worse survival in patients with LHI and RHI (p=0.041). On multivariate Cox regression analysis, extra-MV cardiac involvement, haemoglobin level and technical success were independent predictors of the primary endpoint occurrence. CONCLUSIONS: Grading cardiac involvement may help refine risk stratification, since at least 1 group of extra-MV cardiac involvement represents in itself a negative predictor of midterm outcome.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estimación de Kaplan-Meier , Análisis Multivariante , Pacientes , Resultado del Tratamiento , Cateterismo Cardíaco
12.
Cardiovasc Revasc Med ; 35: 19-26, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33933374

RESUMEN

PURPOSE: To compare in-hospital outcome of Evolut-R 34 mm vs. smaller Evolut-R devices and to identify predictors of paravalvular leak (PVL) and deep implantation specific for Evolut-R 34 mm. METHODS: This single-center retrospective study included 359 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with Evolut-R 34 mm (N = 84,23.4%) and Evolut-R 23/26/29 mm (N = 275,76.6%) between 2016 and 2019. RESULTS: Patients in Evolut-R 34 mm group were more frequently males, had lower STS score, ejection fraction, and mean aortic gradient compared to the Evolut-R 23/26/29 mm group. Horizontal aorta and large LVOT were more frequent findings in the Evolut-R 34 mm group, whereas calcium volume was comparable among the groups. During TAVR, mean implantation depth and contrast volume were greater in the Evolut-R 34 mm group, compared to the Evolut 23/26/29 mm group. Post-procedurally, 30-day mortality, ≥moderate PVL, device success and pacemaker implantation (PM) rates were comparable between groups. Among independent predictors of ≥moderate PVL, calcium volume (OR:1.04; p < 0.001) was predictive with different thresholds in both groups, whereas aortic angulation (OR:1.40; p = 0.005) was predictive only in Evolut-R 34 mm group at a cutoff of 60° (AUC:0.73; p = 0.043). Body weight (OR:1.03; p = 0.027), left ventricular outflow tract (LVOT) diameter (OR:1.34; p = 0.001), and mean aortic gradient (OR:0.96; p = 0.006) were independent predictors of deep implantation (mean depth ≥ 6 mm), with LVOT>27 mm being predictive specifically for Evolut-R 34 mm (AUC:0.66; p = 0.024). CONCLUSIONS: TAVR with Evolut-R 34 mm and Evolut-R 23/26/29 mm showed comparable in-hospital outcome. Aortic angulation >60° and LVOT >27 mm were predictive respectively of ≥moderate PVL and deep implantation specifically in Evolut-R 34 mm patients.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Hospitales , Humanos , Masculino , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Int J Cardiol ; 349: 39-45, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-34826500

RESUMEN

BACKGROUND: A-FMR is considered a specific sub-type of secondary MR in patients with atrial fibrillation (AF) and preserved left ventricle ejection fraction (LVEF). Aim of the study was to investigate the acute and mid-term outcomes of transcatheter edge-to-edge mitral valve repair (TMVr) with the MitraClip in atrial functional mitral regurgitation (A-FMR). METHODS: The study included patients with A-FMR and concomitant AF who underwent to the MitraClip at 7 Italian Centers. Aim of the study was to assess the safety, efficacy and mid-term cardiovascular outcomes. RESULTS: After reviewing 1153 patients with FMR treated with TMVr from 2009 to 2021, 87 patients (median age 81 years, 61% female) with A-FMR were identified. Technical success was achieved in 97%, 30-day device success in 83% and 30-day procedural success in 80%. All-cause death at 30-day was 5%. Estimated two-year freedom from all-cause death and cardiac death was 60% and 77%, respectively, whereas freedom from all-cause death/heart failure hospitalization was 55%. Residual MR ≤ 2+ was encountered in 89% (n = 47/53) and improvement in NYHA class I/II in 79% (n = 48/61). Post-procedural MR ≥ 2+ (HR 5.400, CI 1.371-21.268) and inter-commissural annular diameter ≥ 35 mm (HR 4.159, CI 1.057-16.363) were independent predictors of all-cause death/heart failure hospitalization during the follow-up. Positive reverse remodeling of left atrium and mitral annular dimensions occurred after TMVr during the follow-up. CONCLUSIONS: MitraClip resulted to be a safe and effective option to treat A-FMR in elderly patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Femenino , Atrios Cardíacos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Resultado del Tratamiento
14.
Eur J Heart Fail ; 23(10): 1765-1774, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34318980

RESUMEN

AIMS: In patients with heart failure and reduced ejection fraction (HFrEF) and secondary mitral regurgitation (SMR), impaired right ventricular function (RVF) may negatively influence the prognosis. Percutaneous mitral valve repair (pMVR) can promote the recovery of RVF. We sought to characterize the response of the right ventricle to pMVR in HFrEF with SMR and to assess the association between improved RVF after pMVR and outcomes. METHODS AND RESULTS: Overall, 221 patients with HFrEF and SMR ≥3+ successfully treated with pMVR in four tertiary care centres for heart failure were included. Improved RVF was defined as Δ right ventricular fractional area change (ΔRVFAC) ≥5% at early follow-up (median time 4 months). The primary endpoint was a composite of death/heart transplantation (D/HT). Mean age was 69 ± 11 years, mean left ventricular ejection fraction was 31 ± 8% and mean RVFAC was 34 ± 9%. ΔRVFAC ≥5% occurred in 88 patients (40%) and was independent of the measures of left ventricular reverse remodelling. During a median follow-up of 29 months (interquartile range 12-46), 81 patients (37%) reached the primary endpoint. After adjustment for other significant covariates, ΔRVFAC ≥5% was significantly associated with lower risk of D/HT (hazard ratio 0.52, 95% confidence interval 0.29-0.94, P = 0.030). In the secondary outcome analysis exploring the risk of heart failure hospitalizations, ΔRVFAC ≥5% confirmed the prognostic association with the endpoint. CONCLUSIONS: In patients with HFrEF and SMR, about 40% of patients improved RVF after pMVR. RVF improvement was associated with better long-term survival free from HT and lower risk of heart failure hospitalization.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Humanos , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
15.
Eur J Heart Fail ; 23(8): 1364-1376, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33742754

RESUMEN

AIMS: The Italian Society of Interventional Cardiology (GIse) registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) was conceived in order to assess the safety and efficacy of MitraClip therapy in Italy. The aim of this study was to assess procedural and mid-term outcomes, and clinical and echocardiographic predictors of mid-term mortality after MitraClip therapy, stratifying the results according to the diagnosis of functional and degenerative mitral regurgitation (FMR vs. DMR). METHODS AND RESULTS: Between January 2016 and March 2020, 1659 patients were prospectively included in the GIOTTO registry (FMR 59.4% vs. DMR 40.6%). Acute Mitral Valve Academic Research Consortium (MVARC) technical success was achieved in 97.2% of patients, without differences between FMR and DMR and with sustained results at 30 days. In the study population, all-cause mortality was 4.0%, 17.5% and 34.6% at 30 days, 1 year and 2 years, respectively. Cardiovascular death was the most frequent cause of mortality. Overall hospitalization rates were 6.3%, 23.4% and 31.7% at 30 days, 1 year and 2 years, respectively. The most frequent cause of hospitalization was heart failure, particularly in the first 30 days. FMR and MVARC structural and functional failure were strongly associated with 1-year mortality. Residual mitral regurgitation 1+ (rMR) was independently related to a reduced risk of 1-year mortality (hazard ratio 0.62; P = 0.005). Coherently, at 2-year follow up, FMR was associated with worse outcomes than DMR, and Kaplan-Meier all-cause mortality was related to rMR. CONCLUSIONS: Functional mitral regurgitation aetiology affects 1-year mortality after MitraClip implantation, and differences in mortality and hospitalization rates between FMR and DMR can be observed within 2 years. Optimal rMR 1+ was correlated to a more favourable mid-term outcome, particularly in FMR.


Asunto(s)
Cardiología , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Italia/epidemiología , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Resultado del Tratamiento
16.
J Cardiovasc Echogr ; 30(Suppl 1): S45-S53, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32566466

RESUMEN

Cardiac tumors (CTs) are extremely rare, with an incidence of approximately 0.02% in autopsy series. Primary tumors of the heart are far less common than metastatic tumors. CTs usually present with any possible clinical combination of heart failure, arrhythmias, or embolism. Echocardiography remains the first diagnostic approach when suspecting a CT which, on the other side, frequently appears unexpectedly during an echocardiographic examination. Yet, cardiac tomography and especially magnetic resonance imaging may offer several adjunctive opportunities in the diagnosis of CTs. Early and exact diagnosis is crucial for the following therapy and outcome of CTs.

17.
Cardiovasc Revasc Med ; 21(9): 1057-1062, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32001165

RESUMEN

BACKGROUND: Available scientific evidence of transcatheter mitral valve repair with the MitraClip comes from randomized controlled trials, which showed controversial results that hardly translate into real-world practice, and from registries of relatively small sample size. AIM: To collect real-world data in a multicenter, prospective, country-level registry. METHODS AND RESULT: The Italian Society of Interventional Cardiology (GIse) Registry Of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO) is an ongoing single-arm, multicenter, prospective registry that started enrollment in February 2016. Clinical end points were defined according to the Mitral Valve Academic Research Consortium (MVARC) criteria. From February 2016 to December 2018, 1189 patients (mean age 76 ±â€¯9.1 years) were enrolled. The main MR etiology was functional (64.9%). MVARC technical success was 96.6%. At 30-day follow-up (n = 1131), MVARC device and procedural success were 92.5% and 87% respectively, and all-cause death was 3%. The majority of patients who died at 30-day had functional MR (69.7%). Mixed etiology (OR 0.94, 95% CI 0.02-0.61) and prolonged length of stay in ICU (OR 0.97, 95% CI 0.95-0.99) were found to be negative independent predictors of device success at 30-day. The EuroSCORE II (OR 0.96, 95% CI 0.93-0.99), LVEDV-I (OR 0.99, 95% CI 0.98-0.99) and prolonged length of stay in ICU (OR 0.98, 95% CI 0.97-0.99) were negative independent factors of MVARC procedural success at 30-day. CONCLUSIONS: The GIOTTO registry is one of the largest prospective registries available on MitraClip and shows favorable acute and 30-day safety and efficacy.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Cardiología , Humanos , Italia , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Resultado del Tratamiento
18.
G Ital Cardiol (Rome) ; 20(4 Suppl 1): 20S-26S, 2019 04.
Artículo en Italiano | MEDLINE | ID: mdl-30994630

RESUMEN

Despite the safety and efficacy of transmitral valve repair techniques, transcatheter mitral valve replacement (TMVR) has emerged as a potential treatment option for patients with severe mitral regurgitation at high or prohibitive surgical risk. To date, over 250 high-risk patients with severe mitral regurgitation have been treated with 10 different TMVR devices, demonstrating the feasibility of this technique. Parallel to the potential advantages of this procedure (reproducible mitral regurgitation reduction, possibility of targeting all potential anatomic variations), many challenges has emerged during the design and implantation phases. Further larger studies with longer follow-up are needed to evaluate safety and efficacy of TMVR.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Humanos , Insuficiencia de la Válvula Mitral/fisiopatología , Índice de Severidad de la Enfermedad
19.
J Cardiovasc Echogr ; 29(2): 78-81, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31392126

RESUMEN

Primary tissue failure of bioprosthetic mitral valves due to cusp perforations or ruptures is an unusual complication on short-term follow-up. An 88-year-old male with a known history of mitral regurgitation (MR) treated with bioprosthetic valve replacement in 2016 was referred to our center for recurrent heart failure. The two-dimensional (2D) transthoracic echocardiography documented an intraprosthetic jet of regurgitation without identifying a clear morphological mechanism, nor quantifying precisely the mitral insufficiency. 3D transesophageal echocardiography (TOE) with the tool FlexiSlice added relevant information by providing insights into the pathophysiological mechanisms of MR. The present case emphasizes the importance of 3D TOE as a fundamental tool for the diagnostic algorithm of bioprosthetic valves failure, even in the more demanding cases.

20.
EuroIntervention ; 14(3): e272-e279, 2018 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-29616629

RESUMEN

AIMS: The aim of this study was to assess the efficacy of a novel percutaneous "deviceless" suture-mediated patent foramen ovale (PFO) closure system. METHODS AND RESULTS: Between June 2016 and October 2017, a prospective registry aimed at assessing the safety and efficacy of the NobleStitch EL (HeartStitch, Fountain Valley, CA, USA) suture-based PFO closure system was carried out at 12 sites in Italy. Among 200 consecutive patients evaluated, 192 were considered suitable for suture-mediated PFO closure (44±13 years, 114 female). Suture of the septum with the NobleStitch EL system was carried out successfully in 186 (96%) patients. Median fluoroscopy time was 16.1 (13.0-22.5) minutes and contrast volume 200 (150-270) ml. At 206±130 days follow-up, contrast transthoracic echocardiography with the Valsalva manoeuvre revealed no RLS (grade 0) in 139 (75%) patients and RLS grade ≤1 in 166 (89%) patients. Significant RLS was present in 20 (11%) patients (grade 2 and 3 in 11 and nine patients, respectively). There were no device-related complications. CONCLUSIONS: The early results of this first Italian registry indicate that the suture-mediated "deviceless" closure of PFO is feasible in the majority of septal anatomies, and provides an effective closure of PFO comparable to traditional devices with a good safety profile at medium-term follow-up.


Asunto(s)
Foramen Oval Permeable , Dispositivo Oclusor Septal , Adulto , Cateterismo Cardíaco , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Suturas , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA