Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Surg Endosc ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014179

RESUMEN

BACKGROUND: Sedation increases colonoscopy risks and prolongs recovery time. We examined whether virtual reality (VR) can substitute for sedation. The primary outcome was the overall satisfaction of patients who underwent colonoscopy with VR headset compared with patients who underwent standard sedation. Pain during the procedure, polyp detection rate (PDR), colonoscopy duration, post-colonoscopy adverse events, post-colonoscopy recovery, time-to-return to daily functions, and turnaround time at the endoscopy unit were secondary outcomes. METHODS: The study was approved by Sheba Medical Center's ethics committee IRB number 21-8177-SMC. Sixty patients were sequentially enrolled in a 1:1 ratio to either standard sedated colonoscopy or VR-unsedated procedure, and all patients signed a written informed consent. 28/30 patients successfully completed the colonoscopy using VR headset. Overall satisfaction score was comparable between the groups. RESULTS: There was no difference between VR and controls in colonoscopy duration, or PDR. VR patients had numerically lower rate of post-colonoscopy adverse events than controls. The proportion of VR patients who reported resuming daily activities on the day of the procedure was significantly higher than in the control group. The VR group patients spent significantly less time in the hospital compared to the control group. CONCLUSIONS: VR technology can provide adequate substitution for sedation for most patients undergoing colonoscopy and offers comparable patient satisfaction and faster return to daily activities.

2.
Isr Med Assoc J ; 26(2): 86-88, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38420978

RESUMEN

BACKGROUND: Completing internal medicine specialty training in Israel involves passing the Israel National Internal Medicine Exam (Shlav Aleph), a challenging multiple-choice test. multiple-choice test. Chat generative pre-trained transformer (ChatGPT) 3.5, a language model, is increasingly used for exam preparation. OBJECTIVES: To assess the ability of ChatGPT 3.5 to pass the Israel National Internal Medicine Exam in Hebrew. METHODS: Using the 2023 Shlav Aleph exam questions, ChatGPT received prompts in Hebrew. Textual questions were analyzed after the appeal, comparing its answers to the official key. RESULTS: ChatGPT 3.5 correctly answered 36.6% of the 133 analyzed questions, with consistent performance across topics, except for challenges in nephrology and biostatistics. CONCLUSIONS: While ChatGPT 3.5 has excelled in English medical exams, its performance in the Hebrew Shlav Aleph was suboptimal. Factors include limited training data in Hebrew, translation complexities, and unique language structures. Further investigation is essential for its effective adaptation to Hebrew medical exam preparation.


Asunto(s)
Internado y Residencia , Humanos , Israel , Biometría , Medicina Interna , Lenguaje
3.
J Clin Med ; 13(13)2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38999246

RESUMEN

Background and Aims: Colonoscopy is a critical diagnostic and therapeutic procedure in gastroenterology. However, it carries risks, including hypoxemia, which can impact patient safety. Understanding the factors that contribute to the incidence of severe hypoxemia, specifically the role of procedure duration, is essential for improving patient outcomes. This study aims to elucidate the relationship between the length of colonoscopy procedures and the occurrence of severe hypoxemia. Methods: We conducted a retrospective cohort study at Sheba Medical Center, Israel, including 21,524 adult patients who underwent colonoscopy from January 2020 to January 2024. The study focused on the incidence of severe hypoxemia, defined as a drop in oxygen saturation below 90%. Sedation protocols, involving a combination of Fentanyl, Midazolam, and Propofol were personalized based on the endoscopist's discretion. Data were collected from electronic health records, covering patient demographics, clinical scores, sedation and procedure details, and outcomes. Statistical analyses, including logistic regression, were used to examine the association between procedure duration and hypoxemia, adjusting for various patient and procedural factors. Results: We initially collected records of 26,569 patients who underwent colonoscopy, excluding 5045 due to incomplete data, resulting in a final cohort of 21,524 patients. Procedures under 20 min comprised 48.9% of the total, while those lasting 20-40 min made up 50.7%. Only 8.5% lasted 40-60 min, and 2.9% exceeded 60 min. Longer procedures correlated with higher hypoxemia risk: 17.3% for <20 min, 24.2% for 20-40 min, 32.4% for 40-60 min, and 36.1% for ≥60 min. Patients aged 60-80 and ≥80 had increased hypoxemia odds (aOR 1.1, 95% CI 1.0-1.2 and aOR 1.2, 95% CI 1.0-1.4, respectively). Procedure durations of 20-40 min, 40-60 min, and over 60 min had aORs of 1.5 (95% CI 1.4-1.6), 2.1 (95% CI 1.9-2.4), and 2.4 (95% CI 2.0-3.0), respectively. Conclusions: The duration of colonoscopy procedures significantly impacts the risk of severe hypoxemia, with longer durations associated with higher risks. This study underscores the importance of optimizing procedural efficiency and tailoring sedation protocols to individual patient risk profiles to enhance the safety of colonoscopy. Further research is needed to develop strategies that minimize procedure duration without compromising the quality of care, thereby reducing the risk of hypoxemia and improving patient safety.

4.
J Crohns Colitis ; 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38721918

RESUMEN

BACKGROUND AND AIMS: Pan-enteric capsule endoscopy (PillCam Crohn's capsule [PCC]) is a useful tool in diagnosing and monitoring Crohn's disease (CD). Eliakim score [ES] reliability and strong correlation to Lewis score (LS) and inflammatory biomarkers have been previously demonstrated using PCC in quiescent CD. We aimed to examine ES performance in active CD and its responsiveness to clinical/biochemical change over time. METHODS: Patients with CD who have started biologics were included, and were prospectively followed with clinical visits, biomarkers, and PCC at baseline, after 14 and 52 weeks. Crohn's disease activity index (CDAI), C-reactive protein (CRP) and fecal-calprotectin (FC) levels were collected, and LS and ES were calculated (independently reviewed by two experienced readers). Inter-class classification (ICC), Spearman's baseline correlation, and repeated-measures correlation (RMC) analyses were performed. RESULTS: 74 patients were included (age: 30.5 [23.3-45.0] years-old, male-50%). 142 PCCs were read (baseline-62, week-14-58, week-52-22). Inter-rater agreement was high for both LS and ES (ICC: 0.872 [p<0.001] and 0.925 [<0.001], respectively). Baseline correlations between FC&ES (r=0.509 [p<0.001]) and FC&LS (r=0.467 [p<0.001]) were comparable (p=0.56). RMC between the inflammatory biomarkers and ES were higher than between the former and LS (Reader-1: CRP- r=0.306 vs. r=0.138 [p=0.057], FC- r=0.479 vs. r=0.297 [p=0.034]; Reader-2 CRP- r=0.376 vs. r=0.204 [p=0.035], FC- r=0.549 vs. r=0.412 [p=0.075]). Moreover, ES was better correlated to CDAI than LS (p=0.036). CONCLUSIONS: ES is a reliable scoring system in assessing pan-enteric mucosal inflammation in active CD, and might have a better responsiveness to clinical/biochemical change over time compared to LS.

5.
J Crohns Colitis ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39120437

RESUMEN

BACKGROUND AND AIMS: Fecal calprotectin (FC) is known to be a sensitive biomarker of colonic inflammation but to a lesser degree of small bowel (SB) inflammation. Moreover, data on FC's diagnostic levels in different SB segments are scarce. We aimed to examine FC's diagnostic levels along the SB-axis in CD. METHODS: This was a post-hoc aggregated analysis of five prospective studies of adult CD patients, who underwent FC testing and SB video capsule endoscopy (VCE). Lewis score (LS) inflammation in different SB segments was tested for correlation with FC level after exclusion of colonic disease. The diagnostic levels of FC for SB inflammatory topographical-gradient were assessed using a receiver operating characteristic. RESULTS: 214 patients were included (age:30 [24-43] year-old, males-57%). For a similar SB inflammatory-activity (LS≥135), FC levels incrementally increased from proximal to distal SB segments (63 [30-121] versus 190 [78-549], p=0.005) and from distal SB segment to the colon (190 [78-549] versus 542 [185-1000], p=0.010). The best FC cutoffs to identify isolated mild proximal/distal SB-inflammation (LS≥135) were 77µgg and 123µgg, respectively. A cutoff of 234µgg was best to detect more significant proximal inflammation (LS≥350) when only mild distal SB-inflammation was present. In sensitivity analyses, this proximal-to-distal FC gradient was maintained when LS≥350 and LS≥790 were used as the inflammatory reference-values. Unlike FC, the magnitude of CRP elevation was unrelated to the topography of inflammation along the SB-axis. CONCLUSIONS: FC may serve as a topographical biomarker of CD-activity, with its sensitivity to identify mucosal inflammation increases from proximal to distal SB segments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA