RESUMEN
Distraction through the physis (chondrodiatasis) is a controversial technique with unpredictable results. However, it has been used in the past for the lengthening and correction of angular deformities of long bones. We report the case of an 11-year-old patient with spondyloepimetaphyseal dysplasia (SEMD) who presented with a severe recurvatum deformity of the left proximal tibia secondary to collapse of the tibial plateau into a large metaphyseal cystic lesion. Using the chondrodiatasis technique with a percutaneously applied Ilizarov circular frame, we were able to correct this deformity. Surprisingly, healing and ossification of the metaphyseal lesion was simultaneously observed at the end of the treatment, a finding which, to the best of our knowledge, has not been previously reported.
Asunto(s)
Quistes Óseos/cirugía , Técnica de Ilizarov , Osteocondrodisplasias/cirugía , Tibia , Quistes Óseos/diagnóstico por imagen , Quistes Óseos/fisiopatología , Tirantes , Moldes Quirúrgicos , Niño , Humanos , Masculino , Osteocondrodisplasias/diagnóstico por imagen , Osteocondrodisplasias/fisiopatología , Radiografía , Rango del Movimiento Articular , Resultado del TratamientoRESUMEN
Cemented fixation of the femoral stem is the gold standard for patients older than 60 years. The importance of reliably achieving an adequate cement mantle has been shown in many studies. Currently, inspection and grading of plain radiographs is the accepted method for study of the cement mantle. However, the reliability of plain radiographs for this purpose has been questioned. In addition, the interobserver agreement of current grading systems has been shown to be limited. A new in vitro method of cement mantle analysis is described. Plastic replicas of six contemporary stems were implanted into femurs from cadavers. The specimens were imaged with a computed tomography scanner. Detailed, computer-assisted analysis of mantle thickness was done. Comparisons were made between designs. A subset was compared with standard radiographs. Plain radiographs overestimated thickness and underestimated the deficiencies. There was significant variability in the mantle produced by the different designs. Commonly used designs had deficiencies in their mantles by standard criteria despite proper surgical technique. The importance of being fully acquainted with the particular implant one uses is emphasized by these results. This is a valuable technique for investigation of the effects on the cement mantle of implant design, surgical technique, and patient anatomy.