Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 149(15): 1172-1182, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38410954

RESUMEN

BACKGROUND: Recent guidelines redefined exercise pulmonary hypertension as a mean pulmonary artery pressure/cardiac output (mPAP/CO) slope >3 mm Hg·L-1·min-1. A peak systolic pulmonary artery pressure >60 mm Hg during exercise has been associated with an increased risk of cardiovascular death, heart failure rehospitalization, and aortic valve replacement in aortic valve stenosis. The prognostic value of the mPAP/CO slope in aortic valve stenosis remains unknown. METHODS: In this prospective cohort study, consecutive patients (n=143; age, 73±11 years) with an aortic valve area ≤1.5 cm2 underwent cardiopulmonary exercise testing with echocardiography. They were subsequently evaluated for the occurrence of cardiovascular events (ie, cardiovascular death, heart failure hospitalization, new-onset atrial fibrillation, and aortic valve replacement) during a follow-up period of 1 year. Findings were externally validated (validation cohort, n=141). RESULTS: One cardiovascular death, 32 aortic valve replacements, 9 new-onset atrial fibrillation episodes, and 4 heart failure hospitalizations occurred in the derivation cohort, whereas 5 cardiovascular deaths, 32 aortic valve replacements, 1 new-onset atrial fibrillation episode, and 10 heart failure hospitalizations were observed in the validation cohort. Peak aortic velocity (odds ratio [OR] per SD, 1.48; P=0.036), indexed left atrial volume (OR per SD, 2.15; P=0.001), E/e' at rest (OR per SD, 1.61; P=0.012), mPAP/CO slope (OR per SD, 2.01; P=0.002), and age-, sex-, and height-based predicted peak exercise oxygen uptake (OR per SD, 0.59; P=0.007) were independently associated with cardiovascular events at 1 year, whereas peak systolic pulmonary artery pressure was not (OR per SD, 1.28; P=0.219). Peak Vo2 (percent) and mPAP/CO slope provided incremental prognostic value in addition to indexed left atrial volume and aortic valve area (P<0.001). These results were confirmed in the validation cohort. CONCLUSIONS: In moderate and severe aortic valve stenosis, mPAP/CO slope and percent-predicted peak Vo2 were independent predictors of cardiovascular events, whereas peak systolic pulmonary artery pressure was not. In addition to aortic valve area and indexed left atrial volume, percent-predicted peak Vo2 and mPAP/CO slope cumulatively improved risk stratification.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Pronóstico , Ecocardiografía de Estrés/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Gasto Cardíaco , Insuficiencia Cardíaca/complicaciones , Oxígeno
2.
J Clin Med ; 12(15)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37568386

RESUMEN

Valvular heart disease is a common disease often necessitating valve replacement. Mechanical heart valves (MHVs) are often used in younger patients because of their longer durability. Their main disadvantage is the need for lifelong anticoagulation. Warfarin is considered a standard treatment, but it is far from perfect. Direct oral anticoagulants (DOACs) are a new and more patient-friendly alternative to warfarin when anticoagulation is required, but have not yet been approved for the indication of mechanical valves. EVIDENCE ACQUISITION: A literature search of Pubmed, Embase, Web of Science (Core Collection), and Cochrane Library (from inception to May 2023) was performed using a search string that was well defined and not modified during the study. An extensive overview of the search terms used in each database can be found in the Appendix. Only prospective clinical trials were included in this review. A total of 10 publications were included in this review. RELEVANCE TO CLINICAL PRACTICE: This systematic review summarizes the different types of DOACs and their possible use in the anticoagulation of mechanical valves. We aim to propose future directions in anticoagulation research for mechanical valves. CONCLUSIONS: DOAC use in MHVs has been halted due to the failure of both dabigatran and apixaban in two major clinical trials. However, rivaroxaban was successful in two small clinical trials. Ample research is still needed to explore new valve designs as well as new anticoagulation targets.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA