Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur Arch Otorhinolaryngol ; 272(1): 77-82, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24318422

RESUMEN

To analyze the presence of chronic cerebrospinal venous insufficiency parameter and vascular abnormalities, in the internal jugular veins (IJVs) and/or vertebral veins in sitting and supine posture, in patients with Meniere's disease compared to healthy general population. A prospective study on 32 patients affected by definite Ménière was performed from February 2012 to January 2013. All subjects underwent an echo-color Doppler examination of the cerebrospinal venous flow. 21 of the 32 Menieric patients showed a statistically significant reflux in the intracranial veins versus healthy (65.6 vs 25%; P < 0.001). A high prevalence of IJVs stenosis with hemodynamic changes (increased velocity or absence of flow) was observed (66.7 vs 33.3%; P < 0.05). The other parameters considered did not show statistically significant differences among the two groups. The results obtained showed a vascular pattern of cerebrospinal venous system present in patients affected by definite Meniere. This vascular impairment significantly affects the vascular areas more directly involved in the venous drainage of the inner ear. Thus venous stasis may be considered a further pathogenetic mechanism for development of Meniere's disease.


Asunto(s)
Venas Yugulares/diagnóstico por imagen , Enfermedad de Meniere/complicaciones , Insuficiencia Venosa/etiología , Adulto , Enfermedad Crónica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Ultrasonografía Doppler en Color , Insuficiencia Venosa/diagnóstico por imagen
2.
Audiol Neurootol ; 18(4): 214-22, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23751613

RESUMEN

This study was designed to investigate the indication and advantages of contralateral implantation after postimplant meningitis (piM). Speech perception assessment, most comfortable levels and high-resolution computer tomography were used to monitor cochlear fibrosis/ossification and clinical changes in outcomes in 5 children affected by meningitis after a variable-time post-cochlear implantation. Ipsilateral ossification was found in 3 children, 1 of whom developed delayed contralateral ossification. These children were implanted on the contralateral side as they all showed deterioration of hearing performance. Results from the present paper and literature analysis suggest that, (1) piM can induce ipsilateral and contralateral ossification, (2) meningitis-induced cochlear ossification is more prone to develop in the presence of a normal cochlear structure and (3) contralateral implantation after piM has proven to be effective in restoring performance when a full electrode insertion is accomplished.


Asunto(s)
Implantación Coclear/efectos adversos , Implantes Cocleares , Sordera/cirugía , Meningitis Neumocócica/etiología , Percepción del Habla/fisiología , Adolescente , Niño , Preescolar , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Enfermedades Cocleares/diagnóstico por imagen , Enfermedades Cocleares/cirugía , Implantación Coclear/métodos , Sordera/diagnóstico por imagen , Femenino , Pruebas Auditivas , Humanos , Masculino , Radiografía , Resultado del Tratamiento
3.
Acta Otolaryngol ; 128(3): 291-6, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18274915

RESUMEN

CONCLUSION: The image quality of 64-MDCT provided excellent definition of the fine osseous structures and individual electrode contacts. Evaluation of electrode distances revealed a more focused stimulation for the Helix contacts, with better optimization of pulse width and frequency of stimulation. OBJECTIVES: A multi-slice CT scan was performed postoperatively to evaluate electrode distance from the modiolus and variability of fitting parameters (M level) for two different types of cochlear implant electrode carriers, CII and 90K implants with 1J and Helix electrode carriers. MATERIALS AND METHODS: The electrode's position in different cochlear implant (CI) electrodes, Advanced Bionics 90K 1J and Helix, was assessed postoperatively in 20 adult patients by means of a 64-MDCT scanner. Axial, coronal, and oblique 0.3 mm multiplanar reconstructions (MPRs) were obtained and datasets were analyzed to assess the intracochlear position and distance from the surface of the electrodes to the bony edge of the modiolus. Patients' fitting characteristics were gathered at the time the CT was performed and correlated to intracochlear measurements. RESULTS: Determination of contact distances confirmed smaller average values for the Helix at the apex and medial segments. Helix electrodes were closer to the modiolus in all segments. Likewise, M level determination showed lower values for the Helix carrier, confirming a more focused stimulation and better optimization of pulse width and frequency of stimulation.


Asunto(s)
Umbral Auditivo/fisiología , Cóclea/diagnóstico por imagen , Implantación Coclear/métodos , Implantes Cocleares , Electrodos Implantados , Procesamiento de Imagen Asistido por Computador , Ajuste de Prótesis , Tomografía Computarizada Espiral , Adulto , Anciano , Cóclea/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Ganglio Espiral de la Cóclea/diagnóstico por imagen , Ganglio Espiral de la Cóclea/fisiopatología
4.
Acta Otorhinolaryngol Ital ; 28(4): 218-20, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18939713

RESUMEN

A rare case of cochlear implant surgery complication is described: air collection behind the ear. A 61-year-old male with a 20-year history of progressive bilateral profound sensorineural hearing loss underwent cochlear implant surgery on the left ear with Clarion Hi-Res 90K (Advanced Bionics, Sylmar, CA, USA). Ten days after surgery, the patient presented visible tumefaction behind the ear corresponding to the receiver-stimulator. Ultrasonography, with a probe of 30 MHz, of the surface behind the ear showed formation of probable liquid content but aspiration with a 20-gauge needle yielded 30 cm3 of air without blood or pus. An unusual case is described of a minor complication occurring in an adult cochlear implant patient presenting a swelling behind the ear that was found to be collected air. Although ultrasonography can be useful to evaluate localization of swelling behind the ear and to differentiate between liquid and solid collection, it is not useful for identification of air collection. The Eustachian tube test can show an abnormally patent tube and prevent this complication.


Asunto(s)
Implantación Coclear/efectos adversos , Pérdida Auditiva Sensorineural/cirugía , Pérdida Auditiva Unilateral/cirugía , Aire , Implantes Cocleares , Pérdida Auditiva Sensorineural/diagnóstico por imagen , Pérdida Auditiva Unilateral/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Ultrasonografía
5.
Acta Otorhinolaryngol Ital ; 26(2): 118-20; discussion 120, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16886855

RESUMEN

Extramedullary plasmacytoma of the head and neck region is a rare malignant tumour comprising approximately 3% of all plasma cell tumours. Approximately 80-90% of extramedullary plasmacytomas involve the Mucosa-Associated Lymphoid Tissue of the upper airways, 75% of these involve the nasal and paranasal regions. Radiotherapy is considered the treatment of choice, surgery being limited to biopsy and to excision of residual disease. A case of extramedullary plasmacytoma of the nasal cavity and ethmoid sinus is reported, in which surgical excision is followed by complementary radiotherapy on the site of the tumour.


Asunto(s)
Neoplasias de los Senos Paranasales/diagnóstico por imagen , Neoplasias de los Senos Paranasales/radioterapia , Plasmacitoma/diagnóstico por imagen , Plasmacitoma/radioterapia , Anciano , Terapia Combinada , Femenino , Humanos , Neoplasias de los Senos Paranasales/cirugía , Plasmacitoma/cirugía , Tomografía Computarizada por Rayos X
6.
J Laryngol Otol ; 127(4): 354-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23433000

RESUMEN

OBJECTIVE: This retrospective, comparative study aimed to assess anatomical and functional results in a group of adults undergoing type I tympanoplasty for subtotal tympanic membrane perforation, using two different types of graft. SUBJECTS AND METHODS: The study included 106 patients affected by chronic otitis media, who underwent underlay type I tympanoplasty, 53 using an autologous chondro-perichondral tragal graft and 53 using temporalis fascia. Anatomical and functional outcomes were evaluated over time. RESULTS: Audiometric results comparing the cartilage and fascia groups at six months and one year after surgery showed no statistically significant differences. Assessment of anatomical outcomes indicated a greater number of complications in the fascia group. CONCLUSION: Functional results indicate the validity of the cartilage tympanoplasty, while anatomical results indicate a slightly better outcome in terms of graft re-perforation and retraction, compared with temporalis fascia at one-year follow up. These results suggest that the cartilage technique is preferable for type I tympanoplasty.


Asunto(s)
Pérdida Auditiva/cirugía , Perforación de la Membrana Timpánica/cirugía , Timpanoplastia/métodos , Adulto , Cartílago/trasplante , Fascia/trasplante , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Perforación de la Membrana Timpánica/fisiopatología , Timpanoplastia/efectos adversos
7.
J Laryngol Otol ; 122(4): e12, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18331660

RESUMEN

OBJECTIVE: We report a case of a rare cochlear implant complication: the introduction of the electrode array into the superior semicircular canal, with intra-operative measurements of neural response reactions suggesting reasonable functioning of the implant. CASE REPORT: A two-year old patient affected by congenital, profound, sensorineural deafness underwent bilateral cochlear implantation at the ENT clinic of the 'La Sapienza' University of Rome. Two Clarion 90k devices were implanted, and electrophysiological and radiological checks were performed. After the introduction of the array in the right side, neural response imaging was performed, and a neural potential was found only on two apical electrodes, at a stimulation intensity of 431 clinical units. The situation differed on the left side, where neural response imaging was present at a stimulation intensity of 300 clinical units on the two electrodes tested (one apical electrode (number three), and one middle electrode (number nine)). Intra-operative radiological assessment with a transorbital plain films was performed as usual in order to assess the position of the electrodes inside the cochlea. This radiography showed the electrode array to be in the superior semicircular canal in the right ear. CONCLUSION: Intra-operative monitoring tests during cochlear implant surgery play different roles; measurement of impedances and neural response imaging can evaluate the integrity of implant electrodes and the status of the electrode-cochlea interface, but it must not be the sole way in which correct positioning of the array is confirmed. In our opinion, intra-operative radiological assessment is mandatory during cochlear implant surgery.


Asunto(s)
Implantación Coclear/métodos , Sordera/cirugía , Cuidados Intraoperatorios/métodos , Preescolar , Cóclea/diagnóstico por imagen , Sordera/congénito , Estimulación Eléctrica , Electrodos Implantados , Cuerpos Extraños/diagnóstico por imagen , Humanos , Radiografía , Canales Semicirculares/diagnóstico por imagen
8.
Adv Otorhinolaryngol ; 65: 133-136, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17245034

RESUMEN

The aim of the study was to investigate changes in middle ear dynamic characteristics caused by both otosclerosis and stapes surgery (platinotomy, prosthesis positioning, ossicular chain maneuver) and to evaluate distortion product otoacoustic emissions (DPOAEs) before and following surgery. The study included 15 patients (12 women, 3 men; mean age 51 years; range 32-69 years) with advanced otosclerosis. All the patients were evaluated with the use of pure-tone audiograms (preoperatively, 5 and 30 days after surgery), stapedial reflexes (preoperatively), and DPOAE recordings (preoperatively, at the end of surgery, and 5 and 30 days after surgery). Changes in the hearing thresholds and in the DPOAE amplitudes were compared. Preoperative tests showed conductive hearing loss, with a mean air-bone gap of 36.6 dB HL ranging from 0.25 to 1 kHz, and no stapedial reflexes were detected. DPOAEs were not measurable preoperatively, and they were detected only in 2 patients at the end of surgery, with low amplitudes in a narrow frequency range. No significant changes occurred in DPOAEs 5 days postoperatively. A month after surgery, improvement in conductive hearing loss was observed; the mean air-bone gap from 0.25 to 1 kHz was 12.9 dB HL, whereas the higher frequencies were still affected by the disease. DPOAEs increased in amplitude in 4 patients, but this was not significant. It remains unclear why DPOAEs are not detected despite a subjective hearing improvement and a sufficiently closed air-bone gap at least in middle and low frequencies. The results of our study show that DPOAEs cannot replace behavioral threshold tests; they may only be included in a battery of tests for a complete clinical follow-up for efficiency monitoring after stapes surgery.


Asunto(s)
Pérdida Auditiva Conductiva/cirugía , Monitoreo Intraoperatorio , Emisiones Otoacústicas Espontáneas/fisiología , Otosclerosis/cirugía , Adulto , Anciano , Audiometría de Tonos Puros , Umbral Auditivo/fisiología , Conducción Ósea/fisiología , Femenino , Estudios de Seguimiento , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Conductiva/fisiopatología , Humanos , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/fisiopatología , Complicaciones Intraoperatorias/cirugía , Masculino , Persona de Mediana Edad , Prótesis Osicular , Otosclerosis/diagnóstico , Otosclerosis/fisiopatología , Reflejo Acústico/fisiología , Sensibilidad y Especificidad , Cirugía del Estribo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA