Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
J Chromatogr A ; 1149(2): 368-76, 2007 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-17416383

RESUMEN

Capillary electrochromatography (CEC) monolithic columns were prepared following a two-step synthetic pathway based on (i) UV-induced in situ radical polymerization of N-acryloxysuccinimide (NAS) and ethylene dimethacrylate (EDMA) and (ii) in situ functionalization of the NAS-containing monolithic matrix with various alkylamines. The first synthetic step was performed using toluene as a porogenic solvent. The successful grafting of the alkylamines onto the reactive matrix was confirmed on the basis of qualitative analysis of Raman spectra recorded before and after the chemical modification step. All the electrochromatographic results indicate a strong dependence of the retention, efficiency and selectivity of the monolithic columns on small variations of mobile phase composition and nature of the grafted aliphatic selector in agreement with the typical reversed-phase behaviour. Van Deemter plots for a series of alkylbenzene homologues injected on a column bearing hexyl-segments as side chains are also presented.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Electroforesis Capilar/métodos , Succinimidas/química , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría Raman
2.
J Chromatogr A ; 1127(1-2): 108-16, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16828487

RESUMEN

High-performance liquid chromatography (HPLC) was used to examine the retention behavior of monomethoxypoly(ethylene glycol)s bearing one hydrophobic naphthyl end group (Nap-MPEG) on beta-cyclodextrin polymer (poly-beta-CD) immobilized on a silica support, under isocratic elution conditions and using water as mobile phase. Studies of retentions and theoretical plate heights H were conducted at infinite dilution by comparing the behavior of Nap-MPEGs having different molecular weight (750, 1000 and 5000 g/mol). The larger is its molecular size, the lower is the retention of the polymer. The linear increase of H with mobile phase velocity reveals slow mass-transfer kinetics arising from the restricted diffusion into the pores of the support. The complexation constants between the Nap-MPEGs and beta-CD in solution (around 500M(-1)) were determined from the decrease of retention observed by adding increasing concentrations of hydroxypropyl beta-CD into the eluent. The peak profiles in mass-overload conditions were studied by fitting a model based upon bi-Langmuir kinetics which assumes a non-uniform support having two types of binding sites and apparent adsorption rate constants are used to describe mass-transfer kinetics. A three-parameter adsorption equilibrium isotherm was sufficient to account for the modifications of peak shapes observed when increasing amounts of polymer were injected. This result indicates an interaction with a heterogeneous poly-beta-CD support mainly composed of low affinity groups, non-saturable in the range of polymer concentration studied. An upper limit was estimated for the equilibrium constant (<1000 M(-1)) characterizing the affinity of Nap-MPEG for the non-saturable sites of the poly-beta-CD support. Large affinity constants (8-9 x 10(4)M(-1)) were found for the interaction of Nap-MPEGs with a small percentage of active sites.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Polietilenglicoles/aislamiento & purificación , Adsorción , Simulación por Computador , Modelos Teóricos , Polietilenglicoles/química , beta-Ciclodextrinas
3.
J Chromatogr A ; 1119(1-2): 34-42, 2006 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-16386750

RESUMEN

High-performance frontal affinity chromatography was employed to study the adsorption-desorption kinetics characterizing the retention of beta-lactoglobulin (beta-LG) onto polyclonal anti-beta-lactoglobulin (anti-beta-LG) chromatographic supports. The adsorption and desorption processes were studied by analyzing two different elution fronts separated by a relatively long rinsing step. The method consists in performing two successive frontal injections of the protein. In between, the column was rinsed with a given volume of mobile phase (buffer alone). During this rinsing stage, a partial desorption may occur and a novel amount of protein could be adsorbed in the second frontal injection step. The whole process (first adsorption, possible desorption, and second adsorption) was simulated by a numerical procedure, in which the column was divided into a large number of slices. A model based on bi-Langmuir type kinetics was used to describe the adsorption of the protein on the support. The model assumes a non-uniform adsorbent with two types of binding sites. At equilibrium the adsorption isotherm is of the bi-Langmuir type. A global adsorption effect was considered which includes the effective binding process and the mass transfer resistances due to the transport to the binding site. Therefore, the column capacity and the kinetic parameters of the model (apparent adsorption and desorption rate constants) were determined from the best fit of the first and second adsorption fronts to the experimental ones. The other parameters of the model are the saturation capacities for the adsorption on each type of sites. The equilibrium affinity constants were estimated in a single experiment from the ratio of the apparent adsorption and desorption rate constants. The high values found (around 10(8) M(-1)) reveal a strong interaction of beta-LG with the immunoadsorbent. Kinetic measurements were carried out at different flow rates. Both the apparent adsorption and desorption kinetics were faster at larger flow rates, indicating an important contribution of the mass transfer resistance in the stagnant fluid at the particle boundary. However, as expected, close values were found for the resulting equilibrium constants calculated from the ratio of the apparent adsorption and desorption rate constant determined at various flow rates.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Técnicas de Inmunoadsorción , Lactoglobulinas/química , Inmunoadsorbentes/química , Cinética , Lactalbúmina/aislamiento & purificación , Lactoglobulinas/aislamiento & purificación
4.
J Chromatogr A ; 1002(1-2): 179-92, 2003 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-12885089

RESUMEN

A chemometric approach, based on the study of the autocovariance function, is described to study isothermal GC chromatograms of multicomponent mixtures: isothermal GC analysis is the method of choice in space missions since it is, to date, the only method compatible with flight constraints. Isothermal GC chromatograms look inhomogeneous and disordered with peak density decreasing at higher retention times: a time axis transformation is proposed to make retention an homogeneous process so that CH2 addition in terms of an homologous series yields a constant retention increment. The time axis is transformed into a new scale based on the retention times of n-alkanes, as they are the basis of the universal Kovats indices procedure. The order introduced into the chromatogram by retention time linearization can be simply singled out by the experimental autocorrelation function (EACF) plot: if constant inter-distances are repeated in different regions of the chromatogram, well-shaped peaks are evident in the EACF plot. By comparison, with a standard mixture it is possible to identify peaks diagnostic of specific molecular structures: study of the EACF plot provides information on sample chemical composition. The procedure was applied to standard mixtures containing compounds representative of the planetary atmospheres that will be investigated in the near future: in particular, those related to Titan's atmosphere (Cassini-Huygens mission) and cometary's nucleus (Rosetta mission). The employed experimental conditions simulated those applied to GC instruments installed on space probes and landers in space missions. The method was applied to two specific investigations related to space research, i.e., a comparison of retention selectivity of different GC columns and identification of the chemical composition of an unknown mixture.


Asunto(s)
Cromatografía de Gases/métodos , Compuestos Orgánicos/análisis , Vuelo Espacial , Estructura Molecular , Compuestos Orgánicos/química , Temperatura , Volatilización
5.
J Chromatogr A ; 1042(1-2): 15-22, 2004 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-15296384

RESUMEN

The binding of an anticancer drug (actinomycin D or ACTD) to double-stranded DNA (dsDNA) was studied by means of high-performance liquid chromatography (HPLC). ACTD is an antitumor antibiotic containing one chromophore group and two pentapeptidic lactone cycles that binds dsDNA. Incubations of ACTD with DNA were performed at physiological pH. The complexed and free ligand concentrations of the mixture were quantified at 440 nm from their separation on a size-exclusion chromatographic (SEC) column using the same buffer for the elution and the sample incubation. The DNA and the ACTD-DNA complexes were eluted at the column exclusion volume while the ligand was retained on the support. An apparent binding curve was obtained by plotting the amount emerging at the exclusion column volume against that eluted at free ACTD retention volume. A dissociating effect was evidenced and the binding parameters were significantly different from those obtained at equilibrium by visible absorbance titration. The equilibrium binding parameters determined by absorption spectroscopy were used as starting data in the numerical simulations of the chromatographic process. The results showed a strong dependency of the apparent binding parameters on the reaction kinetics. Finally the comparison of the apparent binding curve obtained from the HPLC experiments and from the numerical simulations permitted an evaluation of the dissociation rate constant (kd = 0.004 s(-1)).


Asunto(s)
Antibacterianos/química , ADN/química , Dactinomicina/química , Algoritmos , Cromatografía Líquida de Alta Presión , Cinética , Ligandos , Peso Molecular , Termodinámica
6.
J Chromatogr A ; 953(1-2): 17-30, 2002 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-12058931

RESUMEN

Beta-Lactoglobulin is one of the main components of whey proteins. Among other reasons, its allergenicity makes its determination in hypoallergenic foods and bio-pharmaceutical products necessary. Immunoaffinity chromatography is a widely accepted technique for purification and analysis of proteins. Knowledge of the apparent kinetics of the adsorption of beta-lactoglobulin onto the anti-beta-lactoglobulin immunochromatographic column is important to optimize the analytical process. High-performance frontal affinity chromatography was used to study the apparent kinetics of the adsorption process. Langmuir and bi-Langmuir kinetic models, assuming one and two kinds of binding sites, respectively, were used to characterize the adsorption kinetics of beta-lactoglobulin B on a polyclonal immunoadsorbent. Very good fits were obtained with the bi-Langmuir model for two different concentrations of beta-lactoglobulin and this allowed us to calculate the apparent adsorption rate constants and the column capacities for both kinds of sites. Experimental results indicate the possibility that the adsorption process is not irreversible. The values of the apparent dissociation rate constants leading to the best fit were estimated and the affinity constants were calculated.


Asunto(s)
Cromatografía de Afinidad/métodos , Lactoglobulinas/química , Adsorción , Cinética
7.
Artículo en Inglés | MEDLINE | ID: mdl-15236687

RESUMEN

Adamantane-modified compounds are known to form stable complexes with beta-cyclodextrins (beta-CD) by host-guest interactions. In this study, the inclusion complex formed between beta-CD cavities and the adamantane group was evaluated for the elaboration of a cation-exchange support. The synthesis of the chromatographic supports involved three steps: (i) a polymer of beta-CD was grafted to diol-modified silica, (ii) a dextran polymer was modified by both adamantane groups and ionizable COOH functions, (iii) the dextran derivative (Ad-Dex-COOH) was bound to the chromatographic support by complexation between the adamantane groups of the dextran and beta-CD cavities of the support. The polymer immobilization on the beta-CD support was successful as the resulting support exhibited weak cation-exchange properties. The stationary phase was easy to prepare under mild conditions (aqueous media, room temperature) and was quite stable when using aqueous mobile phases. The chromatographic behaviour of model proteins was studied in isocratic elution by examining the effect of salt concentration in the buffer on retention. A mixed retention mode was found for lysozyme, revealing both electrostatic and hydrophobic interactions with the stationary phase.


Asunto(s)
Adamantano/química , Dextranos/química , Polímeros/química , Dióxido de Silicio/química , beta-Ciclodextrinas/química
8.
Anal Chem ; 74(24): 6269-78, 2002 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-12510748

RESUMEN

The Monte Carlo model of chromatography is a description of the chromatographic process from a molecular (microscopic) point of view and it is intrinsically based on the stochastic theory of chromatography originally proposed by Giddings and Eyring. The program was previously validated at infinite dilution (i.e., in linear conditions) by some of the authors of the present paper. In this work, it has been further validated under nonlinear conditions. The correspondence between the Monte Carlo model and the well-known Thomas kinetic model (macroscopic model), for which closed-form solutions are available, is demonstrated by comparing Monte Carlo simulations, performed at different loading factors, with the numerical solutions of the Thomas model calculated under the same conditions. In all the cases investigated, the agreement between Monte Carlo simulations and Thomas model results is very satisfactory. Additionally, the exact correspondence between the Thomas kinetic model and Giddings model, when near-infinite dilution conditions are approached, has been demonstrated by calculating the limit of the Thomas model when the loading factor goes to zero. The model was also validated under limit conditions, corresponding to cases of very slow adsorption-desorption kinetics or very short columns. Different hypotheses about the statistical distributions of the random variables "residence time spent by the molecule in mobile and stationary phase' are investigated with the aim to explain their effect on the peak shape and on the efficiency of the separation.

9.
J Sep Sci ; 27(7-8): 495-503, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15335031

RESUMEN

Two Wall Coated Open Tubular capillary columns, coated with poly(cyanopropylphenyl-dimethyl)siloxane and poly(diphenyl-dimethyl)siloxane stationary phases, have been selected for use in the COmetary SAmpling and Composition space experiment for the separation and identification of the wide range of volatile organic compounds which could be present in cometary nuclei. This article presents the main characteristics of the tandem column system for the analysis of solutes of cometary interest within the constraints of space instrumental operating conditions. The high efficiency of the columns is demonstrated and the influence of the operating conditions on their separation properties are investigated. The studied columns exhibit complementary retention pattern: their use in a dual column system makes it possible to achieve the separation and the identification of the compounds of interest. Finally, the good analytical behavior of the columns when analyzing samples which include large amounts of water, the main presumed volatile in comets, is demonstrated. The presented results thus show the suitability of the selected tandem columns system for the desired analyses, and their performance on adaptation to in-situ cometary chemical investigation.


Asunto(s)
Medio Ambiente Extraterrestre , Compuestos Orgánicos/análisis , Cromatografía de Gases/métodos , Meteoroides , Reproducibilidad de los Resultados , Agua/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA