Med Phys ; 38(3): 1534-46, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21520865

RESUMEN

PURPOSE: The objective of the study was to demonstrate that, in x-ray computed tomography (CT), more than two types of materials can be effectively separated with the use of an energy resolved photon-counting detector and classification methodology. Specifically, this applies to the case when contrast agents that contain K-absorption edges in the energy range of interest are present in the object. This separation is enabled via the use of recently developed energy resolved photon-counting detectors with multiple thresholds, which allow simultaneous measurements of the x-ray attenuation at multiple energies. METHODS: To demonstrate this capability, we performed simulations and physical experiments using a six-threshold energy resolved photon-counting detector. We imaged mouse-sized cylindrical phantoms filled with several soft-tissue-like and bone-like materials and with iodine-based and gadolinium-based contrast agents. The linear attenuation coefficients were reconstructed for each material in each energy window and were visualized as scatter plots between pairs of energy windows. For comparison, a dual-kVp CT was also simulated using the same phantom materials. In this case, the linear attenuation coefficients at the lower kVp were plotted against those at the higher kVp. RESULTS: In both the simulations and the physical experiments, the contrast agents were easily separable from other soft-tissue-like and bone-like materials, thanks to the availability of the attenuation coefficient measurements at more than two energies provided by the energy resolved photon-counting detector. In the simulations, the amount of separation was observed to be proportional to the concentration of the contrast agents; however, this was not observed in the physical experiments due to limitations of the real detector system. We used the angle between pairs of attenuation coefficient vectors in either the 5-D space (for non-contrast-agent materials using energy resolved photon-counting acquisition) or a 2-D space (for contrast agents using energy resolved photon-counting acquisition and all materials using dual-kVp acquisition) as a measure of the degree of separation. Compared to dual-kVp techniques, an energy resolved detector provided a larger separation and the ability to separate different target materials using measurements acquired in different energy window pairs with a single x-ray exposure. CONCLUSIONS: We concluded that x-ray CT with an energy resolved photon-counting detector with more than two energy windows allows the separation of more than two types of materials, e.g., soft-tissue-like, bone-like, and one or more materials with K-edges in the energy range of interest. Separating material types using energy resolved photon-counting detectors has a number of advantages over dual-kVp CT in terms of the degree of separation and the number of materials that can be separated simultaneously.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X/instrumentación , Absorción , Animales , Modelos Lineales , Ratones , Fantasmas de Imagen , Microtomografía por Rayos X
2.
Technol Cancer Res Treat ; 5(4): 343-50, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16866565

RESUMEN

Multi-modality combinations of SPECT/CT and PET/CT have proven to be highly successful in the clinic and small animal SPECT/CT and PET/CT are becoming the norm in the research and drug development setting. However, the use of ionizing radiation from a high-resolution CT scanner is undesirable in any setting and particularly in small animal imaging (SAI), in laboratory experiments where it can result in radiation doses of sufficient magnitude that the experimental results can be influenced by the organism's response to radiation. The alternative use of magnetic resonance (MR) would offer a high-resolution, non-ionizing method for anatomical imaging of laboratory animals. MR brings considerably more than its 3D anatomical capability, especially regarding the imaging of laboratory animals. Dynamic MR imaging techniques can facilitate studies of perfusion, oxygenation, and diffusion amongst others. Further, MR spectroscopy can provide images that can be related to the concentration of endogenous molecules in vivo. MR imaging of injected contrast agents extends MR into the domain of molecular imaging. In combination with nuclear medicine (NM) SPECT and PET modalities in small animal imaging, MR would facilitate studies of dynamic processes such as biodistribution, pharmacokinetics, and pharmacodynamics. However, the detectors for nearly all PET and SPECT systems are still based on vacuum tube technology, namely: photomultiplier tubes (PMT's) in which the signal is generated by transporting electrons over a substantial distance within an evacuated glass tube, making them inoperable in even small magnetic fields. Thus the combination of SPECT or PET with MR has not been practical until the recent availability of semiconductor detectors such as silicon avalanche photodiodes (APD's) for PET and CdZnTe (CZT) detectors for SPECT coupled with the availability of high-density low noise ASIC electronics to read out the semiconductor detectors. The strong advantage of these technologies over PMT's is their insensitivity to magnetic fields which makes their use in co-axial multi-modality nuclear medicine/magnetic resonance instrumentation possible.


Asunto(s)
Diagnóstico por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Medicina Nuclear/métodos , Animales , Computadores , Rayos gamma , Humanos , Imagen por Resonancia Magnética/tendencias , Medicina Nuclear/tendencias , Tomografía de Emisión de Positrones/métodos , Radiación Ionizante , Semiconductores , Factores de Tiempo , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos
3.
Phys Med Biol ; 56(21): 6809-22, 2011 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-21971137

RESUMEN

Despite its high sensitivity, the variable specificity of magnetic resonance imaging (MRI) in breast cancer diagnosis can lead to unnecessary biopsies and over-treatment. Scintimammography (SMM) could potentially supplement MRI to improve the diagnostic specificity. The synergistic combination of MRI and SMM (MRSMM) could result in both high sensitivity from MRI and high specificity from SMM. Development of such a dual-modality system requires the integration of a radio frequency (RF) coil and radiation detector in a strong magnetic field without significant mutual interference. In this study, we developed and tested a unilateral breast array coil specialized for MRSMM imaging. The electromagnetic field, specific absorption ratio and RF coil parameters with cadmium-zinc-telluride detectors encapsulated in specialized RF and gamma-ray shielding mounted within the RF coil were investigated through simulation and experimental measurements. Simultaneous MR and SMM images of a breast phantom were also acquired using the integrated MRSMM system. This work, we feel, represents an important step toward the fabrication of a working MRSMM system.


Asunto(s)
Neoplasias de la Mama/patología , Mama/patología , Imagen por Resonancia Magnética/instrumentación , Mamografía/instrumentación , Neoplasias de la Mama/diagnóstico por imagen , Cadmio , Cobre/química , Campos Electromagnéticos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Mamografía/métodos , Fantasmas de Imagen , Telurio , Zinc
4.
Phys Med Biol ; 56(4): N63-9, 2011 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-21258141

RESUMEN

In this study, we investigated the in vivo application of an integrated small-animal magnetic resonance (MR) and gamma-ray imaging system that consists of a semiconductor-based radiation detector, a parallel-hole collimator, and a specialized radiofrequency coil. Gadodiamide and (99m)Tc sestimibi agents were injected simultaneously into a mouse, and simultaneous dynamic contrast-enhanced MR and scintigraphic images of the kidneys were acquired. The time curves of both the MR signal intensity and radioactivity indicate a rapid uptake of the agents followed by a more gradual excretion, consistent with the previously reported literature. Our results demonstrate the feasibility of measuring multiple biological processes at the same time using both MR contrast agents and radiotracers.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética/métodos , Cintigrafía/métodos , Animales , Femenino , Riñón/diagnóstico por imagen , Ratones , Ratones Endogámicos BALB C , Tecnecio Tc 99m Sestamibi
5.
Technol Cancer Res Treat ; 9(1): 21-8, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20082527

RESUMEN

Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Imagen de Cuerpo Entero/métodos , Animales , Compuestos de Cadmio/química , Ratones , Ratones Desnudos , Fantasmas de Imagen , Radiofármacos , Telurio/química
6.
Phys Med Biol ; 55(6): 1563-75, 2010 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-20164533

RESUMEN

In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B(0) field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Imagen de Cuerpo Entero/métodos , Compuestos de Cadmio/química , Campos Electromagnéticos , Humanos , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/química , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Imagen de Cuerpo Entero/instrumentación , Zinc/química