Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.196
Filtrar
Más filtros

Intervalo de año de publicación
1.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747561

RESUMEN

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
Circulation ; 148(14): 1113-1126, 2023 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-37782695

RESUMEN

The Shock Academic Research Consortium is a multi-stakeholder group, including representatives from the US Food and Drug Administration and other government agencies, industry, and payers, convened to develop pragmatic consensus definitions useful for the evaluation of clinical trials enrolling patients with cardiogenic shock, including trials evaluating mechanical circulatory support devices. Several in-person and virtual meetings were convened between 2020 and 2022 to discuss the need for developing the standardized definitions required for evaluation of mechanical circulatory support devices in clinical trials for cardiogenic shock patients. The expert panel identified key concepts and topics by performing literature reviews, including previous clinical trials, while recognizing current challenges and the need to advance evidence-based practice and statistical analysis to support future clinical trials. For each category, a lead (primary) author was assigned to perform a literature search and draft a proposed definition, which was presented to the subgroup. These definitions were further modified after feedback from the expert panel meetings until a consensus was reached. This manuscript summarizes the expert panel recommendations focused on outcome definitions, including efficacy and safety.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Corazón Auxiliar , Humanos , Choque Cardiogénico/terapia , Choque Cardiogénico/cirugía , Proyectos de Investigación
3.
Am Heart J ; 269: 108-117, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38128897

RESUMEN

Hypertension remains a leading preventable cause of myocardial infarction, stroke, kidney disease, and cardiovascular death worldwide. Despite lifestyle modifications and intensification of medical therapy, suboptimal blood pressure control is common, spurring the development of device-based therapies for hypertension. The US Food and Drug Administration (FDA) assembled the Circulatory System Devices Panel on August 22-23, 2023, to discuss the safety and effectiveness of renal denervation devices manufactured by Recor Medical and Medtronic. After reviewing the ultrasound-based Recor Paradise renal denervation system the day prior, the panel reconvened to discuss the radiofrequency-based Medtronic Symplicity Spyral Renal Denervation System. In this manuscript, we summarize the data presented by the sponsor and FDA and detail the deliberation and discussion during the meeting.


Asunto(s)
Sistema Cardiovascular , Hipertensión , Estados Unidos , Humanos , United States Food and Drug Administration , Riñón/cirugía , Presión Sanguínea , Simpatectomía , Resultado del Tratamiento , Antihipertensivos/uso terapéutico
4.
Am Heart J ; 275: 21-34, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38815781

RESUMEN

Tricuspid regurgitation (TR) is common and associated with significant mortality and morbidity. Because the effectiveness and safety of medical and surgical treatments are limited, there is a significant unmet need for the treatment of this disease. Therefore, there is a growing market for percutaneous devices that offer safer, less invasive, and more effective treatment options in this patient population. On February 13, 2024, the US Food and Drug Administration (FDA) convened a meeting of the Circulatory System Devices Panel to discuss the safety and effectiveness of the TriClip Transcatheter Valve Repair System (Abbott, Santa Clara, CA, USA). Several important points were discussed, including newly published data from the TRILUMINATE Pivotal study, the use of patient-oriented outcomes for device approval, and a discussion about training requirements and rollout plans when approving a breakthrough device. In this manuscript, we summarize the data presented by the sponsor and FDA and describe the deliberations and discussions during the meeting.

5.
Am Heart J ; 271: 112-122, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38395293

RESUMEN

BACKGROUND: To date, there has been no independent core lab angiographic analysis of patients with COVID-19 and STEMI. The study characterized the angiographic parameters of patients with COVID-19 and STEMI. METHODS: Angiograms of patients with COVID-19 and STEMI from the North American COVID-19 Myocardial Infarction (NACMI) Registry were sent to a Core Laboratory in Vancouver, Canada. Culprit lesion(s), Thrombolysis In Myocardial Infarction (TIMI) flow, Thrombus Grade Burden (TGB), and percutaneous coronary intervention (PCI) outcome were assessed. RESULTS: From 234 patients, 74% had one culprit lesion, 14% had multiple culprits and 12% had no culprit identified. Multivessel thrombotic disease and multivessel CAD were found in 27% and 53% of patients, respectively. Stent thrombosis accounted for 12% of the presentations and occurred in 55% of patients with previous coronary stents. Of the 182 who underwent PCI, 60 (33%) had unsuccessful PCI due to post-PCI TIMI flow <3 (43/60), residual high thrombus burden (41/60) and/or thrombus related complications (27/60). In-hospital mortality for successful, partially successful, and unsuccessful PCI was 14%, 13%, and 27%, respectively. Unsuccessful PCI was associated with increased risk of in-hospital mortality (risk ratio [RR] 1.96; 95% CI: 1.05-3.66, P = .03); in the adjusted model this estimate was attenuated (RR: 1.24; 95% CI: 0.65-2.34, P = .51). CONCLUSION: In patients with COVID-19 and STEMI, thrombus burden was pervasive with notable rates of multivessel thrombotic disease and stent thrombosis. Post-PCI, persistent thrombus and sub-optimal TIMI 3 flow rates led to one-third of the PCI's being unsuccessful, which decreased over time but remained an important predictor of in-hospital mortality.


Asunto(s)
COVID-19 , Angiografía Coronaria , Intervención Coronaria Percutánea , Sistema de Registros , Infarto del Miocardio con Elevación del ST , Humanos , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , COVID-19/complicaciones , COVID-19/terapia , Masculino , Femenino , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricos , Persona de Mediana Edad , Anciano , Mortalidad Hospitalaria , SARS-CoV-2 , Trombosis Coronaria/diagnóstico por imagen , Canadá/epidemiología
6.
Artículo en Inglés | MEDLINE | ID: mdl-38860616

RESUMEN

In the absence of standardized management guidelines, coronary artery aneurysms (CAAs) present therapeutic challenges. Percutaneous coronary intervention (PCI) is rarely explored, especially in giant aneurysms with persistent angina, where surgery might be presumed as a preferred option. We describe the technical aspects and feasibility of PCI using Gore Viabahn expanded polytetrafluoroethylene (ePTFE)-covered nitinol self-expanding stents in a 66-year-old woman with a complex medical history and an enlarging, symptomatic right coronary artery aneurysm. The case was complicated by endoleak after the first stent, but intravascular ultrasound guidance enabled the precise deployment of additional stents, resulting in the successful exclusion of the aneurysm. This case demonstrates steps to successful CAA PCI with Gore Viabahn ePTFE-covered nitinol self-expanding stents and emphasizes that in unsuitable surgical candidates, PCI might be a potential alternative for symptomatic CAAs.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38713867

RESUMEN

Hypertension continues to be a prominent, avoidable factor contributing to major vascular issues on a global scale. Even with lifestyle adjustments and more aggressive medical treatments, maintaining optimal blood pressure levels remains challenging. This challenge has driven the emergence of device-oriented approaches to address hypertension. To assess the safety and efficacy of the Recor Paradise Ultrasound Renal Denervation System, the Circulatory System Devices Panel was convened by the US Food and Drug Administration (FDA). This manuscript provides a condensed overview of the information put forth by the sponsor and the FDA, along with an account of the considerations and conversations that took place during the meeting.

8.
Catheter Cardiovasc Interv ; 103(4): 523-531, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38440914

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) is considered less safe in patients with reduced ejection fraction (EF), an impression based on older data. Whether the safety and durability of contemporary PCI are different in patients with reduced EF compared with normal EF patients is unknown. METHODS: Patients from the BIOFLOW II, IV and V clinical trials were grouped as normal EF (≥50%) and reduced EF (30%-50%). Using multivariable logistic regression and cox proportional hazards regression, we determined relations of EF category with procedural safety (a composite of cardiac death, myocardial infarction, stroke and urgent coronary artery bypass grafting within 30 days of PCI) and target lesion failure (TLF; comprising cardiac death, target vessel myocardial infarction, target vessel revascularization within 1 year of PCI) respectively. In sensitivity analyses, we regrouped patients into EF < 45% and ≥55% and repeated the aforementioned analyses. RESULTS: In 1685 patients with normal EF (mean age 65 years; 27% women; mean EF 61%) and 259 with low EF (mean age 64 years; 17% women; mean EF 41%), 101 safety and 148 TLF events occurred. Compared with patients in the normal EF group, those with reduced EF had neither a statistically significant higher proportion of safety events, nor a higher multivariable-adjusted risk for such events. Similarly, patients with reduced EF and normal EF did not differ in terms of TLF event proportions or multivariable-adjusted risk for TLF. The results were similar in sensitivity analyses with EF groups redefined to create a 10% between-group EF separation. CONCLUSION: PCI safety and durability outcomes are similar in patients with mild-moderately reduced EF and normal EF.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Disfunción Ventricular Izquierda , Humanos , Femenino , Anciano , Persona de Mediana Edad , Masculino , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Infarto del Miocardio/etiología , Puente de Arteria Coronaria/efectos adversos , Disfunción Ventricular Izquierda/etiología , Muerte
9.
Catheter Cardiovasc Interv ; 103(5): 691-694, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38440925

RESUMEN

BACKGROUND: With advances in technology and technique, the expectations are that patients undergoing procedures in the cardiac catheterization laboratory will not need to return for a repeat procedure within the same day. OBJECTIVES: Report why subjects undergoing cardiac procedures return urgently to the catheterization laboratory for a repeat procedure during the same day. METHODS: We retrospectively reviewed patients who were brought back to the cardiac catheterization laboratory within the same day for a repeat procedure. The reasons for index and repeat procedure were identified. Patients who were transferred from an outside center after an initial procedure at other centers were excluded. RESULTS: Between November 2013 and January 2022, 55,942 catheterization procedures were performed at our institution, of which 140 entries were included in our analysis. Common reasons for the index procedure were diagnostic angiography (35.0%), percutaneous coronary intervention (PCI, 29.2%), and transcatheter aortic valve replacement (15.0%). The most common reason for bringing these patients back to the cardiac catheterization laboratory within the same day was vascular complications (24.2%), followed by repeat PCI (20.7%), need for hemodynamic support (15.0%), heart team discussion and PCI (10%), and pacemaker implantation (10%). Acute limb ischemia was the most commonly identified vascular complication (7.1%), followed by pseudoaneurysm (5%). CONCLUSION: Our study demonstrates that a very small number of patients underwent repeat procedures within the same day. Special attention should be paid to vascular access and closure and assessment of recurrent chest pain postprocedure, as these are the main reasons for same-day repeat procedures.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Angiografía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos
10.
Catheter Cardiovasc Interv ; 103(6): 917-923, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38605682

RESUMEN

The advent of excimer laser coronary atherectomy (ELCA) nearly four decades ago heralded a novel way to treat complex lesions, both coronary and peripheral, which were previously untraversable and thus untreatable. These complex lesions include heavily calcified lesions, ostial lesions, bifurcation lesions, chronic total occlusions, in-stent restenosis (including stent underexpansion), and degenerative saphenous vein grafts. We discuss the technology of ELCA, its indications, applications, and complications, and suggest the "MAXCon ELCA" technique for better outcomes without increased risk. Lastly, we present a case of MAXCon ELCA effectively treating a complex lesion.


Asunto(s)
Aterectomía Coronaria , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Láseres de Excímeros , Humanos , Medios de Contraste , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Láseres de Excímeros/uso terapéutico , Solución Salina/administración & dosificación , Resultado del Tratamiento
11.
Catheter Cardiovasc Interv ; 103(5): 703-709, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38520176

RESUMEN

BACKGROUND: Full adoption of coronary microvascular dysfunction (CMD) assessment faces challenges due to its invasive nature and concerns about prolonged procedure time and increased contrast and/or radiation exposure. We compared procedural aspects of CMD invasive assessment to diagnostic left heart catheterization (DLHC) in patients with chest pain who were not found to have obstructive coronary artery disease. METHODS: A total of 227 patients in the Coronary Microvascular Disease Registry were compared to 1592 patients who underwent DLHC from August 2021 to November 2023. The two cohorts were compared using propensity-score matching; primary outcomes were fluoroscopy time and total contrast use. RESULTS: The participants' mean age was 64.1 ± 12.6 years. CMD-assessed patients were more likely to be female (66.5% vs. 45.2%, p < 0.001) and have hypertension (80.2% vs. 44.5%, p < 0.001), history of stroke (11.9% vs. 6.3%, p = 0.002), and history of myocardial infarction (20.3% vs. 7.7%, p < 0.001). CMD assessment was safe, without any reported adverse outcomes. A propensity-matched analysis showed that patients who underwent CMD assessment had slightly higher median contrast exposure (50 vs. 40 mL, p < 0.001), and slightly longer fluoroscopy time (6.9 vs. 4.7 min, p < 0.001). However, there was no difference in radiation dose (209.3 vs. 219 mGy, p = 0.58) and overall procedure time (31 vs. 29 min, p = 0.37). CONCLUSION: Compared to DLHC, CMD assessment is safe and requires only slightly additional contrast use (10 mL) and slightly longer fluoroscopy time (2 min) without clinical implications. These findings emphasize the favorable safety and feasibility of invasive CMD assessment.


Asunto(s)
Enfermedad de la Arteria Coronaria , Angina Microvascular , Infarto del Miocardio , Isquemia Miocárdica , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Angina Microvascular/diagnóstico , Circulación Coronaria , Microcirculación , Vasos Coronarios/diagnóstico por imagen
12.
Artículo en Inglés | MEDLINE | ID: mdl-38769727

RESUMEN

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.

13.
Catheter Cardiovasc Interv ; 101(7): 1235-1238, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37061866

RESUMEN

Suture-based vascular closure devices have been shown to be effective in hemostasis for procedures with vascular access. However, iatrogenic vascular occlusion may occur. The cutting balloon (CB) is a noncompliant balloon wrapped with 3-4 microsurgical blades that are intended to modify vascular lesions, but it may also be utilized to cut and release endovascular sutures. We report two cases in which the CB was employed as a bailout strategy to alleviate suture-related vascular occlusion after transcatheter aortic valve replacement. The CB can be effectively utilized to resolve suture-related vascular occlusion.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Venus , Humanos , Técnicas Hemostáticas/efectos adversos , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Resultado del Tratamiento , Suturas , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
14.
Catheter Cardiovasc Interv ; 102(7): 1177-1185, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37925616

RESUMEN

BACKGROUND: Bleeding events are associated with higher mortality rates in patients with cardiovascular diseases, including patients presenting with acute coronary syndrome (ACS) undergoing coronary revascularization. We aimed to determine whether a reduction in hemoglobin (Hgb) from pre- to postpercutaneous coronary intervention (PCI), with or without evidence of clinical bleeding, is a correlate of in-hospital mortality for patients presenting with ACS who underwent primary PCI. METHODS: We divided 33816 consecutive patients with ACS who underwent PCI into three categories: (1) target group (defined as Hgb reduction without overt bleeding [n = 112]); (2) Hgb reduction with overt bleeding (n = 48); and (3) control group (defined as no Hgb reduction and no overt bleeding [n = 3156]). Hgb reduction was defined as a drop of >3 g/dL in Hgb value from preprocedure and postprocedure during the index hospitalization. The primary outcome was in-hospital mortality. We used logistic regression to examine the relationship between Hgb reduction with and without bleeding and in-hospital mortality. RESULTS: In crude analysis, the Hgb reduction with overt bleed group had a higher in-hospital mortality rate (16.7%) than the target (9.8%) and control groups (0.6%). Adjusted logistic regression estimates a 0.393 (95% confidence interval [CI]: 0.137, 1.869) odds ratio for in-hospital death of the target group over the Hgb reduction with bleed group, and a 54.517 (95% CI: 2.07, >1000) odds ratio of the target group over the control group. CONCLUSIONS: In patients presenting with ACS undergoing PCI, Hgb reduction with and without overt bleeding were both independently associated with in-hospital mortality.


Asunto(s)
Síndrome Coronario Agudo , Intervención Coronaria Percutánea , Humanos , Pronóstico , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Síndrome Coronario Agudo/complicaciones , Intervención Coronaria Percutánea/efectos adversos , Mortalidad Hospitalaria , Resultado del Tratamiento , Factores de Riesgo , Hemorragia/etiología , Hemoglobinas
15.
Curr Cardiol Rep ; 25(4): 213-227, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36847990

RESUMEN

PURPOSE OF REVIEW: Cardiogenic shock (CS) is a complex clinical entity that continues to carry a high risk of mortality. The landscape of CS management has changed with the advent of several temporary mechanical circulatory support (MCS) devices designed to provide hemodynamic support. It remains challenging to understand the role of different temporary MCS devices in patients with CS, as many of these patients are critically ill, requiring complex care with multiple MCS device options. Each temporary MCS device can provide different types and levels of hemodynamic support. It is important to understand the risk/benefit profile of each one of them for appropriate device selection in patients with CS. RECENT FINDINGS: MCS may be beneficial in CS patients through augmentation of cardiac output with subsequent improvement of systemic perfusion. Selecting the optimal MCS device depends on several variables including the underlying etiology of CS, clinical strategy of MCS use (bridge to recovery, bridge to transplant or durable MCS, or abridge to decision), amount of hemodynamic support needed, associated respiratory failure, and institutional preference. Furthermore, it is even more challenging to determine the appropriate time to escalate from one MCS device to another or combine different MCS devices. In this review, we discuss the current available data published in the literature on the management of CS and propose a standardized approach for escalation of MCS devices in patients with CS. Shock teams can play an important role to help in hemodynamic-guided management and algorithm-based step-by-step approach in early initiation and escalation of temporary MCS devices at different stages of CS. It is important to define the etiology of CS, and stage of shock and recognize univentricular vs biventricular shock for appropriate device selection and escalation of therapy.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Humanos , Choque Cardiogénico/terapia , Medición de Riesgo , Hemodinámica
16.
Am Heart J ; 247: 90-99, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35150637

RESUMEN

There are a limited number of donor hearts available for transplantation every year, and an even lower number of these hearts actually undergo transplantation. One of the barriers to utilizing donor hearts is the inferior outcomes associated with prolonged ischemic times. There have been increasing attempts to develop alternative techniques for prolonged storage to raise the number of heart transplants while maintaining acceptable outcomes. One such new technology utilizes continuous ex vivo perfusion of the donor heart with oxygenated blood and allows for prolonged storage and preservation times. The TransMedics Organ Care System (OCS) Heart (TransMedics; Andover, MA) claims to optimize the condition of the donor organs by preserving them in a warm, functioning environment. On April 6, 2021, the United States Food and Drug Administration convened a virtual meeting of the Circulatory System Devices Panel of the Medical Devices Advisory Committee to provide guidance on the TransMedics OCS Heart System's application for premarket approval. This application was subsequently approved on September 7, 2021. We provide an overview of the meeting, including the results of the clinical trials that were presented.


Asunto(s)
Trasplante de Corazón , Corazón , Trasplante de Corazón/métodos , Humanos , Perfusión/métodos , Donantes de Tejidos , Estados Unidos , United States Food and Drug Administration
17.
Catheter Cardiovasc Interv ; 99(6): 1789-1795, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35084082

RESUMEN

Despite advances in transcatheter aortic valve replacement (TAVR) technology, periprocedural stroke remains a complication of TAVR procedures. The TriGUARD 3 device is designed to be positioned in the aortic arch to deflect debris away from the brachiocephalic, left common carotid, and left subclavian arteries during TAVR. The United States Food and Drug Administration (FDA) assembled the Circulatory System Devices Panel to review safety and effectiveness data for the TriGUARD 3 device. Because of the coronavirus disease 2019 pandemic, this meeting was held virtually. In this manuscript, we summarize the data presented by both the sponsor and FDA, as well as the panel discussion.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Dispositivos de Protección Embólica , Embolia Intracraneal , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Embolia Intracraneal/etiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados Unidos , United States Food and Drug Administration
18.
Catheter Cardiovasc Interv ; 99(7): 1998-2005, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35485729

RESUMEN

OBJECTIVES: We aimed to compare bare-metal stents (BMS), durable-polymer everolimus-eluting stents (DP-EES), and abluminal biodegradable-polymer sirolimus-eluting stents (ABP-SES) in the bifurcation model setup. BACKGROUND: The mechanism of thrombogenicity, which differs among second-generation stents implanted using double-kissing (DK) crush or culotte stenting techniques, remains unclear. We have shown previously that setting up a porcine arteriovenous shunt model is feasible and useful to assess thrombogenicity at vessel bifurcation points. METHODS: Six porcine shunt models were prepared for the comparison between DK crush and culotte stenting techniques using BMS, DP-EES, and ABP-SES. Intracoronary imaging with high-resolution optical coherence tomography (OCT) was performed to evaluate the thrombogenicity in different stent types in the bifurcation stenting model and was evaluated by a core lab. RESULTS: Culotte stenting demonstrated more thrombogenicity at the proximal main branch (MB) with DP-EES, side branch (SB) with BMS, and the bifurcation site irrespective of the stent type, while DK crush technique exhibited thrombogenicity only at SB with BMS and ABP-SES. OCT analysis revealed malapposition of DP-EES in the proximal MB with culotte stenting. Stent expansion was generally larger in ABP-SES than BMS and DP-EES. CONCLUSIONS: The study provides hypothesis-generating findings in distinct thrombogenicity of bifurcation stenting with DP- or ABP-coated drug-eluting stents.


Asunto(s)
Stents , Tomografía de Coherencia Óptica , Animales , Everolimus , Humanos , Polímeros , Diseño de Prótesis , Sirolimus , Porcinos , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 99(3): 822-826, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34480524

RESUMEN

OBJECTIVES: To analyze post-marketing surveillance data from the United States Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database for the VASCADE Vascular Closure System (Cardiva Medical Inc., Santa Clara, CA). BACKGROUND: The VASCADE Vascular Closure System is a closure device for femoral arterial and venous access-site closure that was approved by the FDA in 2013. However, post-marketing data and experience on the most commonly reported complications and modes of failure associated with the VASCADE Vascular Closure System are limited. METHODS: Post-marketing surveillance data from the FDA MAUDE database from October 2013 through March 2020 were analyzed, yielding 201 reports. RESULTS: Of the 201 reports of major complications involving VASCADE devices, 156 reports involved either injury (145) or death (11) related to the device. Of the 145 injury reports, bleeding was the most common adverse outcome described (85), followed by pseudoaneurysm (29) and pulselessness of an extremity (21). The device malfunction incidents (41 reports) were reported in three main categories, with deployment failure being the most commonly reported complication. CONCLUSIONS: Our analysis of the MAUDE database demonstrates that in contemporary post-marketing practice, physicians should be well-trained and educated to use the VASCADE closure device because improper utilization is a common cause of device failure, and complications with the VASCADE device can have profound clinical implications.


Asunto(s)
Arteria Femoral , Mercadotecnía , Bases de Datos Factuales , Arteria Femoral/diagnóstico por imagen , Humanos , Resultado del Tratamiento , Estados Unidos/epidemiología , United States Food and Drug Administration
20.
Catheter Cardiovasc Interv ; 99(2): 418-423, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33491870

RESUMEN

OBJECTIVES: Assess the impact on fluoroscopy time and contrast use in patients with tortuous brachiocephalic/thoracic aortas undergoing right transradial coronary angiography (RTCA) and provide strategies to manage. BACKGROUND: Unfavorable anatomy with severe brachiocephalic/thoracic tortuosity, referred to as an "elephant head," remains a significant obstacle for RTCA. METHODS: We reviewed the coronary angiograms of patients who underwent RTCA and had tortuous aortas. Angiography was attempted first using a universal catheter (Tiger) and switched to a left coronary specific catheter (Judkins Left [JL]) if challenging. Fluoroscopy time, contrast volume, and greatest distance from the patient's midline to the catheter in the aorta were recorded. RESULTS: Forty-nine patients (62.6 ± 12.0 years, 69.4% male) were included. Fifteen (30.6%) patients underwent successful angiography with a Tiger catheter; 34 (69.4%) patients required switching to JL catheter. The average distance of Tiger catheters to the midline of the spine was 0.78 ± 0.41 cm versus 1.28 ± 0.44 cm (p = .001) in JL catheters. Tiger catheter use resulted in less fluoroscopy time (6.48 ± 4.73 min) and contrast use (58.87 ± 43.53 ml) than in cases switched to JL (13.26 ± 10.76 min [p = .026]; 86.5 ± 69.95 ml [(p = .017]). CONCLUSIONS: For patients undergoing RTCA with significant brachiocephalic/thoracic aorta tortuosity, "elephant head," a Tiger catheter can be used efficiently for curvatures <1 cm from the middle of the spine. We propose that for curvatures >1 cm, operators should consider immediately switching to a JL catheter.


Asunto(s)
Elefantes , Animales , Aorta Torácica/diagnóstico por imagen , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Femenino , Fluoroscopía , Humanos , Masculino , Arteria Radial/diagnóstico por imagen , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA