Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38513110

RESUMEN

AIMS: Catheter ablation (CA) of post-ablation left atrial tachycardias (LATs) can be challenging. So far, pulsed field ablation (PFA) has not been compared to standard point-by-point radiofrequency current (RFC) energy for LAT ablation. To compare efficacy of PFA vs. RFC in patients undergoing CA for LAT. METHODS AND RESULTS: Consecutive patients undergoing LAT-CA were prospectively enrolled (09/2021-02/2023). After electro-anatomical high-density mapping, ablation with either a pentaspline PFA catheter or RFC was performed. Patients were matched 1:1. Ablation was performed at the assumed critical isthmus site with additional ablation, if necessary. Right atrial tachycardia (RAT) was ablated with RFC. Acute and chronic success were assessed. Fifty-six patients (n = 28 each group, age 70 ± 9 years, 75% male) were enrolled.A total of 77 AT (n = 67 LAT, n = 10 RAT; 77% macroreentries) occurred with n = 32 LAT in the PFA group and n = 35 LAT in the RFC group. Of all LAT, 94% (PFA group) vs. 91% (RFC group) successfully terminated to sinus rhythm or another AT during ablation (P = 1.0). Procedure times were shorter (PFA: 121 ± 41 vs. RFC: 190 ± 44 min, P < 0.0001) and fluoroscopy times longer in the PFA group (PFA: 15 ± 9 vs. RFC: 11 ± 6 min, P = 0.04). There were no major complications. After one-year follow-up, estimated arrhythmia free survival was 63% (PFA group) and 87% (RFC group), [hazard ratio 2.91 (95% CI: 1.11-7.65), P = 0.0473]. CONCLUSION: Pulsed field ablation of post-ablation LAT using a pentaspline catheter is feasible, safe, and faster but less effective compared to standard RFC ablation after one year of follow-up. Future catheter designs and optimization of the electrical field may further improve practicability and efficacy of PFA for LAT.

2.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702961

RESUMEN

AIMS: Clinical concerns exist about the potential proarrhythmic effects of the sodium channel blockers (SCBs) flecainide and propafenone in patients with cardiovascular disease. Sodium channel blockers were used to deliver early rhythm control (ERC) therapy in EAST-AFNET 4. METHODS AND RESULTS: We analysed the primary safety outcome (death, stroke, or serious adverse events related to rhythm control therapy) and primary efficacy outcome (cardiovascular death, stroke, and hospitalization for worsening of heart failure (HF) or acute coronary syndrome) during SCB intake for patients with ERC (n = 1395) in EAST-AFNET 4. The protocol discouraged flecainide and propafenone in patients with reduced left ventricular ejection fraction and suggested stopping therapy upon QRS prolongation >25% on therapy. Flecainide or propafenone was given to 689 patients [age 69 (8) years; CHA2DS2-VASc 3.2 (1); 177 with HF; 41 with prior myocardial infarction, coronary artery bypass graft, or percutaneous coronary intervention; 26 with left ventricular hypertrophy >15 mm; median therapy duration 1153 [237, 1828] days]. The primary efficacy outcome occurred less often in patients treated with SCB [3/100 (99/3316) patient-years] than in patients who never received SCB [SCBnever 4.9/100 (150/3083) patient-years, P < 0.001]. There were numerically fewer primary safety outcomes in patients receiving SCB [2.9/100 (96/3359) patient-years] than in SCBnever patients [4.2/100 (135/3220) patient-years, adjusted P = 0.015]. Sinus rhythm at 2 years was similar between groups [SCB 537/610 (88); SCBnever 472/579 (82)]. CONCLUSION: Long-term therapy with flecainide or propafenone appeared to be safe in the EAST-AFNET 4 trial to deliver effective ERC therapy, including in selected patients with stable cardiovascular disease such as coronary artery disease and stable HF. Clinical Trial Registration ISRCTN04708680, NCT01288352, EudraCT2010-021258-20, www.easttrial.org.


Asunto(s)
Antiarrítmicos , Flecainida , Bloqueadores de los Canales de Sodio , Humanos , Anciano , Masculino , Femenino , Resultado del Tratamiento , Persona de Mediana Edad , Flecainida/uso terapéutico , Flecainida/efectos adversos , Antiarrítmicos/uso terapéutico , Antiarrítmicos/efectos adversos , Bloqueadores de los Canales de Sodio/uso terapéutico , Bloqueadores de los Canales de Sodio/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Factores de Tiempo , Frecuencia Cardíaca/efectos de los fármacos , Accidente Cerebrovascular
3.
Circ J ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839350

RESUMEN

BACKGROUND: Achieving early rhythm control and maintaining sinus rhythm are associated with improved outcomes in patients with atrial fibrillation (AF). Pulmonary vein isolation (PVI) is a validated alternative to medical rhythm control. This study determined associations between left atrial strain reservoir (LASR) and AF recurrence after PVI.Methods and Results: In all, 132 patients (88 with paroxysmal AF [PAF], 44 with persisting AF [PersAF]) who presented in sinus rhythm for de novo PVI of AF between December 2017 and January 2019 were included in the study. All patients underwent preprocedural echocardiography. After 12 months, all patients underwent 24-h Holter electrocardiogram monitoring to screen for AF recurrence. Kaplan-Meier curve analysis revealed an association between decreasing LASRand increased AF recurrence, with a cut-off at 31.4%. In univariable Cox regression analysis, LASRdemonstrated an association with AF recurrence, with hazard ratios (HR) of 0.83 (95% confidence interval [CI] 073-0.93; P=0.001) per 5% increase in univariable models and 0.83 (95% CI 073-0.95; P=0.005) in multivariable analysis. When clinical variables with age, sex and type of AF (PAF/PersAF) were included in the multivariable analysis, LASRremained relevant in a model with age (HR 0.86; 95% CI 073-1.00; P=0.046). CONCLUSIONS: In patients undergoing de novo PVI for AF, LASRcould be of use in risk stratification regarding AF recurrence.

4.
Artículo en Alemán | MEDLINE | ID: mdl-38684158

RESUMEN

In recent years, invasive resuscitation methods utilizing veno-arterial extracorporeal membrane oxygenation (VA-ECMO) have gained significant attention. Despite advances in traditional resuscitation measures, out-of-hospital cardiac arrest (OHCA) mortality remains high. In the context of extracorporeal cardiopulmonary resuscitation (ECPR), VA-ECMO therapy offers a promising approach by providing circulatory support during cardiac arrest, allowing time for diagnostic evaluation and targeted therapy. However, patient selection for ECPR remains a challenge, relying on various factors including initial rhythm, duration of no-flow and low-flow states, as well as presence of reversible causes.Recent studies such as the ARREST, Prague OHCA and INCEPTION trials have investigated the efficacy of ECPR in OHCA patients, yielding mixed results. While the ARREST trial demonstrated a survival benefit with ECPR, the Prague OHCA and INCEPTION trials showed varying outcomes, reflecting the complexity of patient selection and treatment strategies. Despite inherent risks and complications associated with ECPR, it may offer a potential survival advantage under optimal conditions.Future directions in ECPR involve the development of innovative treatment protocols such as the CARL therapy, which incorporates specialized ECMO systems and tailored perfusion solutions. Early studies indicate promising outcomes with CARL therapy, emphasizing the importance of a well-coordinated and structured approach to ECPR implementation.In summary, ECPR shows promise in improving survival rates for OHCA patients within a well-organized healthcare system. However, further research is needed to refine patient selection criteria and optimize treatment protocols, ultimately enhancing patient outcomes in cardiac arrest scenarios.


Asunto(s)
Reanimación Cardiopulmonar , Oxigenación por Membrana Extracorpórea , Paro Cardíaco Extrahospitalario , Humanos , Reanimación Cardiopulmonar/métodos , Paro Cardíaco Extrahospitalario/terapia , Resultado del Tratamiento , Predicción , Selección de Paciente
5.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38102318

RESUMEN

AIMS: In-hospital complications of catheter ablation for atrial fibrillation (AF), atrial flutter (AFL), and ventricular tachycardia (VT) may be overestimated by analyses of administrative data. METHODS AND RESULTS: We determined the incidences of in-hospital mortality, major bleeding, and stroke around AF, AFL, and VT ablations in four German tertiary centres between 2005 and 2020. All cases were coded by the G-DRG- and OPS-systems. Uniform code search terms were applied defining both the types of ablations for AF, AFL, and VT and the occurrence of major adverse events including femoral vascular complications, iatrogenic tamponade, stroke, and in-hospital death. Importantly, all complications were individually reviewed based on patient-level source records. Overall, 43 031 ablations were analysed (30 361 AF; 9364 AFL; 3306 VT). The number of ablations/year more than doubled from 2005 (n = 1569) to 2020 (n = 3317) with 3 times and 2.5 times more AF and VT ablations in 2020 (n = 2404 and n = 301, respectively) as compared to 2005 (n = 817 and n = 120, respectively), but a rather stable number of AFL ablations (n = 554 vs. n = 612). Major peri-procedural complications occurred in 594 (1.4%) patients. Complication rates were 1.1% (n = 325) for AF, 1.0% (n = 95) for AFL, and 5.3% (n = 175) for VT. With an increase in complex AF/VT procedures, the overall complication rate significantly increased (0.76% in 2005 vs. 1.81% in 2020; P = 0.004); but remained low over time. Following patient-adjudication, all in-hospital cardiac tamponades (0.7%) and strokes (0.2%) were related to ablation. Major femoral vascular complications requiring surgical intervention occurred in 0.4% of all patients. The in-hospital mortality rate adjudicated to be ablation-related was lower than the coded mortality rate: AF: 0.03% vs. 0.04%; AFL: 0.04% vs. 0.14%; VT: 0.42% vs. 1.48%. CONCLUSION: Major adverse events are low and comparable after catheter ablation for AFL and AF (∼1.0%), whereas they are five times higher for VT ablations. In the presence of an increase in complex ablation procedures, a moderate but significant increase in overall complications from 2005-20 was observed. Individual case analysis demonstrated a lower than coded ablation-related in-hospital mortality. This highlights the importance of individual case adjudication when analysing administrative data.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Accidente Cerebrovascular , Taquicardia Ventricular , Humanos , Mortalidad Hospitalaria , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Aleteo Atrial/etiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/cirugía , Hospitales , Accidente Cerebrovascular/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
6.
Eur Heart J Case Rep ; 8(7): ytae312, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39021359

RESUMEN

Background: Cardiovascular imaging plays an important role in identifying pre-existing cardiac comorbidity prior to the decision on cancer therapy and serves as a reference for detecting changes during treatment and long-term follow-up and also in the further identification of a possible cardiac manifestation of the underlying oncological disease. Case summary: We report the case of an 81-year-old patient with a malignant melanoma. The patient initially was presented before the start of adjuvant therapy with serine/threonine-protein kinase B-Raf/mitogen-activated extracellular signal-regulated kinase inhibitors. Cardiologic staged diagnostics using transthoracic echocardiography, transoesophageal echocardiography, and cardiovascular magnetic resonance imaging (CMR) revealed with a high probability a cardiac manifestation of the underlying disease. The echocardiographic and CMR results as well as the diagnostic workup are presented. Discussion: Cardiac masses in general have a variety of differential diagnoses. Cardiac metastases are much more common than primary neoplasms in a ratio of about 10:1. Cardiovascular risk stratification is recommended in all patients with cancer before starting potentially cardiotoxic anticancer therapy. Cardiovascular imaging plays an important role for baseline risk stratification but is also the leading diagnostic tool in the differential diagnosis of cardiac tumours and the planning of a potential therapy.

7.
Clin Res Cardiol ; 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619577

RESUMEN

BACKGROUND: Catheter ablation of atrial fibrillation and atrial flutter is routinely performed in patients with implantable devices. The aim of the present study was to assess success rates and potential complications in a large registry cohort of patients with cardiac pacemakers. METHODS AND RESULTS: The German Ablation Registry is a nationwide, prospective registry with a 1-year follow-up investigating patients who underwent catheter ablation of supraventricular arrhythmias in 51 German centers. The present analysis focussed on the presence of cardiac pacemakers in 591 patients undergoing catheter ablation of atrial fibrillation or atrial flutter. These were compared to 7393 patients without a pacemaker. Patients with pacemakers were significantly older and presented more comorbidities like diabetes, renal failure, cardiovascular disease, or previous stroke. One-year mortality (2.4% vs. 1.3%, p = 0.022) and a combined endpoint of death, myocardial infarction, and stroke (3.6% vs. 2.1%, p = 0.014) were significantly elevated in patients with pacemakers. Re-hospitalization was also more common in patients with a pacemaker (53.3% vs. 45.0%, p < 0.01). After adjustment for important comorbidities, pre-existing pacemaker systems did not show any negative effect. Procedural success was reported in 98.8% vs. 98.4% (p = 0.93). Device-related complications were only observed in 0.4% of patients with pacemakers. CONCLUSION: Patients with pacemaker systems undergoing catheter ablation of atrial fibrillation or atrial flutter demonstrate an increased risk of death, cardiovascular events, and re-hospitalization. This observation can be largely attributed to an older patient population and an increased rate of comorbidities.

8.
Heart ; 110(11): 800-807, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38388469

RESUMEN

OBJECTIVES: The association of pulmonary hypertension (PH) with the outcome after mitral transcatheter edge-to-edge repair (M-TEER) focusing on the new ESC/ERS guidelines definition for PH. BACKGROUND: PH is frequently found in patients with mitral regurgitation and is associated with lower survival rates. Recent studies were based on echocardiographic parameters, but results based on invasive haemodynamics differentiating distinct types of PH using the new definition for PH are missing. METHODS: 449 consecutive M-TEER-treated patients from December 2009 to February 2015 were included in this retrospective analysis. All patients were stratified by the distinct types of PH (no PH, precapillary PH, isolated postcapillary PH, combined post-PH and precapillary PH) according to the definitions of the ESC/ERS guidelines for the diagnosis of PH from 2015 (meanPA cut-off <25 mm Hg, pulmonary capillary wedge pressure (PCWP) cut-off ≤15 mm Hg, diastolic pulmonary gradient cut-off ≥7 mm Hg or pulmonary vascular resistance (PVR) >3 WU) and 2022 (meanPA cut-off ≤20 mm Hg, PCWP cut-off ≤15 mm Hg, PVR cut-off ≥3 WU). RESULTS: Patients with any type of PH (2015: meanPA cut-off 25 mm Hg; 2022: meanPA cut-off >20 mm Hg) showed a higher risk of death after M-TEER compared with patients with no PH (2015: HR 1.61 (95% CI 1.25 to 2.07); p<0.001 and 2022: HR 2.09 (95% CI 1.54 to 2.83); p<0.001). Based on the new PH definition, each PH subgroup showed a lower survival after M-TEER compared with patients with no PH. Echocardiographic estimated systolic PAP showed a correlation with invasively measured mean pulmonary artery pressure (mPAP) (r=0.29, p<0.001) and systolic pulmonary arterial pressure (r=0.34,p<0.001). Cox-regression analysis showed higher invasive diastolic, systolic and mean pulmonary pressures were associated with higher all-cause mortality (p<0.001). In addition, invasive measured higher right atrial pressure, lower pulmonary arterial compliance, higher PVR and higher wedge pressure were identified as predictors of all-cause mortality after M-TEER. CONCLUSIONS: The new PH definition discriminates PH groups and mortality better than the old definition. The lower threshold of mPAP of 20mmHg improved prognostication in this cohort of patients.


Asunto(s)
Cateterismo Cardíaco , Hipertensión Pulmonar , Insuficiencia de la Válvula Mitral , Humanos , Hipertensión Pulmonar/fisiopatología , Hipertensión Pulmonar/mortalidad , Hipertensión Pulmonar/diagnóstico , Femenino , Masculino , Estudios Retrospectivos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/complicaciones , Anciano , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Presión Esfenoidal Pulmonar/fisiología , Persona de Mediana Edad , Factores de Riesgo , Hemodinámica/fisiología
9.
J Clin Med ; 13(13)2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-38999424

RESUMEN

Background: The number of young patients receiving ICDs or CRT-Ds has been increasing in recent decades and understanding the key characteristics of this special population is paramount to optimized patient care. Methods: The DEVICE I+II registry prospectively enrolled patients undergoing ICD/CRT-D implantation or revision from 50 German centers between 2007 and 2014 Data on patient characteristics, procedural outcome, adverse events, and mortality during the initial stay and 1-year follow-up were collected. All patients under the age of 45 years were identified and included in a comparative analysis with the remaining population. Results: A total number of 5313 patients were enrolled into the registry, of which 339 patients (6.4%) were under the age of 45 years. Mean age was 35.0 ± 8.2 vs. 67.5 ± 9.7 years, compared to older patients (≥45 years). Young patients were more likely to receive an ICD (90.9 vs. 69.9%, p < 0.001) than a CRT-D device (9.1 vs. 30.1%). Coronary artery disease was less common in younger patients (13.6 vs. 63.9%, p < 0.001), whereas hypertrophic cardiomyopathy (10.9 vs. 2.7%, p < 0.001) and primary cardiac electrical diseases (11.2 vs. 1.5%, p < 0.001) were encountered more often. Secondary preventive ICD was more common in younger patients (51.6 vs. 39.9%, p < 0.001). Among those patients, survival of sudden cardiac death (66.7 vs. 45.4%, p < 0.001) due to ventricular fibrillation (60.6 vs. 37.9%, p < 0.001) was the leading cause for admission. There were no detectable differences in postoperative complications requiring intervention (1.5 vs. 1.9%, p = 0.68) or in-hospital mortality (0.0 vs. 0.3%, p = 0.62). Median follow-up duration was 17.9 [13.4-22.9] vs. 16.9 [13.1-23.1] months (p = 0.13). In younger patients, device-associated complications requiring revision were more common (14.1 vs. 8.3%, p < 0.001) and all-cause 1-year-mortality after implantation was lower (2.9 vs. 7.3%, p = 0.003; HR 0.39, 95%CI: 0.2-0.75) than in older patients. Conclusions: Young patients < 45 years of age received defibrillator therapy more often for secondary prevention. Rates for periprocedural complications and in-hospital mortality were very low and without differences between groups. Young patients have lower mortality during follow-up but experienced a higher rate of postoperative complications requiring revision, potentially due to a more active lifestyle.

10.
Thromb Haemost ; 2024 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-38555641

RESUMEN

OBJECTIVE AND BACKGROUND: Data on incidence of in-hospital pulmonary embolisms (PE) after catheter ablation (CA) are scarce. To gain further insights, we sought to provide new findings through case-based analyses of administrative data. METHODS: Incidences of PE after CA of supraventricular tachycardias (SVT), atrial fibrillation (AF), atrial flutter (AFlu), and ventricular tachycardias (VT) in three German tertiary centers between 2005 and 2020 were determined and coded by the G-DRG (German Diagnosis Related Groups System) and OPS (German Operation and Procedure Classification) systems. An administrative search was performed with a consecutive case-based analysis. RESULTS: Overall, 47,344 ablations were analyzed (10,037 SVT; 28,048 AF; 6,252 AFlu; 3,007 VT). PE occurred in 14 (0.03%) predominantly female (n = 9; 64.3%) patients with a mean age of 55.3 ± 16.9 years, body mass index 26.2 ± 5.1 kg/m2, and left ventricular ejection fraction of 56 ± 13.6%. PE incidences were 0.05% (n = 5) for SVT, 0.02% (n = 5) for AF, and 0.13% (n = 4) for VT ablations. No patient suffered PE after AFlu ablation. Five patients (35.7%) with PE after CA had no prior indication for oral anticoagulation (OAC). Preprocedural international normalized ratio in PE patients was 1.2 ± 0.5. Most patients with PE following CA presented with symptoms the day after the procedure (n = 9) after intraprocedural heparin application of 12,943.2 ± 5,415.5 IU. PE treatment included anticoagulation with either phenprocoumon (n = 5) or non-vitamin K-dependent OAC (n = 9). Two patients with PE died after VT/AF ablation, respectively. The remaining patients were discharged without sequels. CONCLUSION: Over a 15-year period, incidence of PE after ablation is low, particularly low in patients with ablation for AF/AFlu. This is most likely due to stricter anticoagulation management in these patients compared with those receiving SVT/VT ablation procedures and could argue for continuation of OAC prior to ablation. Optimizing periprocedural anticoagulation management should be subject of further prospective trials.

11.
Clin Res Cardiol ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38771346

RESUMEN

AIMS: For patients with symptomatic drug-refractory atrial fibrillation (AF), catheter ablation to achieve rhythm control is an important therapeutic option. The atrial mechanical dispersion measured as standard deviation of the time to peak strain (SD-TPS) is associated with the risk of AF recurrence following catheter ablation. METHODS: The study cohort prospectively enrolled n = 132 consecutive patients with paroxysmal (n = 88) or persistent AF (n = 44) presenting for de novo pulmonary vein isolation (PVI) and followed for 1 year. We related left atrial (LA) volume, LA ejection fraction, SD-TPS, and global longitudinal strain of the left ventricle and clinical variables (sex, age, and type of AF) to AF recurrence. RESULTS: Kaplan-Meier curves showed higher AF recurrence rate with an increase of SD-TPS with the calculated cut-off of 38.6 ms. Uni- and multivariable Cox regression analysis could show that SD-TPS had the highest relevance regarding AF recurrence with a HR of 1.05 (95% CI, 1.01; 1.09, p = 0.01) and HR of 1.05 (95% CI, 1.01; 1.09, p = 0.02) per 10 ms increase. In the additional analyses for the model including the clinical variables age, sex, and type of AF with paroxysmal or persisting AF, SD-TPS did only show a trend and after adjusting for covariates, SD-TPS showed a HR of 1.04 (95% CI, 0.99; 1.09, p = 0.09) per 10 ms increase. CONCLUSION: Atrial mechanical dispersion was associated with recurrent AF.

12.
Artículo en Inglés | MEDLINE | ID: mdl-38864809

RESUMEN

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

13.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38430087

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Masculino , Femenino , Anciano , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Estudios Retrospectivos , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento , Sistema de Registros
14.
Artículo en Inglés | MEDLINE | ID: mdl-38869506

RESUMEN

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

15.
J Clin Med ; 13(1)2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38202063

RESUMEN

Background: Survival following cardiac arrest (CA) remains poor after conventional cardiopulmonary resuscitation (CCPR) (6-26%), and the outcomes after extracorporeal cardiopulmonary resuscitation (ECPR) are often inconsistent. Poor survival is a consequence of CA, low-flow states during CCPR, multi-organ injury, insufficient monitoring, and delayed treatment of the causative condition. We developed a new strategy to address these issues. Methods: This all-comers, multicenter, prospective observational study (69 patients with in- and out-of-hospital CA (IHCA and OHCA) after prolonged refractory CCPR) focused on extracorporeal cardiopulmonary support, comprehensive monitoring, multi-organ repair, and the potential for out-of-hospital cannulation and treatment. Result: The overall survival rate at hospital discharge was 42.0%, and a favorable neurological outcome (CPC 1+2) at 90 days was achieved for 79.3% of survivors (CPC 1+2 survival 33%). IHCA survival was very favorable (51.7%), as was CPC 1+2 survival at 90 days (41%). Survival of OHCA patients was 35% and CPC 1+2 survival at 90 days was 28%. The subgroup of OHCA patients with pre-hospital cannulation showed a superior survival rate of 57.1%. Conclusions: This new strategy focusing on repairing damage to multiple organs appears to improve outcomes after CA, and these findings should provide a sound basis for further research in this area.

17.
Rev. bras. cir. cardiovasc ; 34(3): 368-371, Jun. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1013464

RESUMEN

Abstract The Bridge Occlusion Balloon is a compliant balloon, specifically designed for temporary Superior vena cava occlusion in case of Superior Vena Cava laceration during lead extraction procedures. We here report the first case, using Bridge Occlusion Ballon for a venous angioplasty in a patient with dysfunctional pacemaker leads and symptomatic Superior Vena Cava occlusion. After successful lead extraction, venography was showing a narrow venous canal. Therefore, venous angioplasty using the Bridge balloon was performed. Especially for high-risk lead extraction cases in patients with Superior Vena Cava stenosis, the Bridge Occlusion Ballon might be used as a combination of a safety-net in case of Superior Vena Cava perforation and for Superior Vena Cava angioplasty.


Asunto(s)
Humanos , Masculino , Anciano de 80 o más Años , Síndrome de la Vena Cava Superior/terapia , Angioplastia de Balón Asistida por Láser/métodos , Síndrome de la Vena Cava Superior/diagnóstico por imagen , Flebografía/métodos , Factores de Riesgo , Resultado del Tratamiento , Angiografía por Tomografía Computarizada/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA