RESUMEN
We report on experiments demonstrating coherent control of magnon spin transport and pseudospin dynamics in a thin film of the antiferromagnetic insulator hematite utilizing two Pt strips for all-electrical magnon injection and detection. The measured magnon spin signal at the detector reveals an oscillation of its polarity as a function of the externally applied magnetic field. We quantitatively explain our experiments in terms of diffusive magnon transport and a coherent precession of the magnon pseudospin caused by the easy-plane anisotropy and the Dzyaloshinskii-Moriya interaction. This experimental observation can be viewed as the magnonic analog of the electronic Hanle effect and the Datta-Das transistor, unlocking the high potential of antiferromagnetic magnonics toward the realization of rich electronics-inspired phenomena.
RESUMEN
Applications based on spin currents strongly rely on the control and reduction of their effective damping and their transport properties. We here experimentally observe magnon mediated transport of spin (angular) momentum through a 13.4-nm thin yttrium iron garnet film with full control of the magnetic damping via spin-orbit torque. Above a critical spin-orbit torque, the fully compensated damping manifests itself as an increase of magnon conductivity by almost 2 orders of magnitude. We compare our results to theoretical expectations based on recently predicted current induced magnon condensates and discuss other possible origins of the observed critical behavior.
RESUMEN
Seventy mortalities of North Atlantic right whales Eubalaena glacialis (NARW) were documented between 2003 and 2018 from Florida, USA, to the Gulf of St. Lawrence, Canada. These included 29 adults, 14 juveniles, 10 calves, and 17 of unknown age class. Females represented 65.5% (19/29) of known-sex adults. Fourteen cases had photos only; 56 carcasses received external examinations, 44 of which were also necropsied. Cause of death was determined in 43 cases, of which 38 (88.4%) were due to anthropogenic trauma: 22 (57.9%) from entanglement, and 16 (42.1%) from vessel strike. Gross and histopathologic lesions associated with entanglement were often severe and included deep lacerations caused by constricting line wraps around the flippers, flukes, and head/mouth; baleen plate mutilation; chronic extensive bone lesions from impinging line, and traumatic scoliosis resulting in compromised mobility in a calf. Chronically entangled whales were often in poor body condition and had increased cyamid burden, reflecting compromised health. Vessel strike blunt force injuries included skull and vertebral fractures, blubber and muscle contusions, and large blood clots. Propeller-induced wounds often caused extensive damage to blubber, muscle, viscera, and bone. Overall prevalence of NARW entanglement mortalities increased from 21% (1970-2002) to 51% during this study period. This demonstrates that despite mitigation efforts, entanglements and vessel strikes continue to inflict profound physical trauma and suffering on individual NARWs. These cumulative mortalities are also unsustainable at the population level, so urgent and aggressive intervention is needed to end anthropogenic mortality in this critically endangered species.
Asunto(s)
Especies en Peligro de Extinción , Ballenas , Animales , Océano Atlántico , Canadá , Femenino , FloridaRESUMEN
The observation of the spin Hall effect triggered intense research on pure spin current transport. With the spin Hall effect, the spin Seebeck effect and the spin Peltier effect already observed, our picture of pure spin current transport is almost complete. The only missing piece is the spin Nernst (-Ettingshausen) effect, which so far has been discussed only on theoretical grounds. Here, we report the observation of the spin Nernst effect. By applying a longitudinal temperature gradient, we generate a pure transverse spin current in a Pt thin film. For readout, we exploit the magnetization-orientation-dependent spin transfer to an adjacent yttrium iron garnet layer, converting the spin Nernst current in Pt into a controlled change of the longitudinal and transverse thermopower voltage. Our experiments show that the spin Nernst and the spin Hall effect in Pt are of comparable magnitude, but differ in sign, as corroborated by first-principles calculations.
Asunto(s)
Hierro , TemperaturaRESUMEN
OBJECTIVES: The aim of this study is to evaluate the adhesion between PEEK and two self-adhesive resin cements after plasma treatment. METHODS: Eight hundred sixty-four polyetheretherketone (PEEK) disks were cut and polished to silicon carbide (SIC) P4000. One half of the specimens were randomly selected and pretreated with plasma, whereas the remaining 432 specimens remained untreated. Subsequently, specimens were randomly allocated to four groups (n = 108/group): Visio.link (Bredent), Signum PEEK Bond (Heraeus Kulzer), Ambarino P60 (Creamed), and a control group without additional treatment. Half of the specimens of each group (n = 54) were then cemented with either RelyX Unicem Automix 2 (3 M ESPE) or with Clearfil SA (Kuraray). All specimens were stored in water for 24 h (37 °C). Afterwards, specimens were divided into three groups (n = 18) for different aging levels: (1) no aging (baseline measurement), (2) thermal aging for 5,000 cycles (5/55 °C), and (3) thermal aging for 10,000 cycles (5/55 °C). Thereafter, shear bond strengths (SBS) were measured, and failure types (adhesive, mixed, and cohesive) were assessed. Data were analyzed using descriptive statistics, four- and one-way ANOVA followed by a post hoc Scheffé test (p < 0.05). RESULTS: No adhesion could be established without adhesive pretreatment, irrespectively, whether plasma was applied or not. Also, no bond strength was measured when Ambarino P60 was applied. In contrast, adhesive pretreatment resulted in SBS ranging between 8 and 15 MPa. No significant differences were found between the resin cements used. In general, no cohesive failures were observed. Groups without plasma treatment combined with Visio.link or Signum PEEK Bond showed predominantly mixed failure types. Control groups, plasma treated, or treated using Ambarino P60 groups fractured predominantly adhesively. CONCLUSION: The use of methyl methacrylate (MMA)-based adhesives allows bonding between PEEK and self-adhesive resin cements. Plasma treatment has no impact on bond to resin cements. CLINICAL SIGNIFICANCE: PEEK reconstructions can be cemented using self-adhesive resin cements combined with pretreatment with MMA-based adhesives.
Asunto(s)
Cementos Dentales , Cetonas/química , Gases em Plasma , Polietilenglicoles/química , Resistencia al Corte , Benzofenonas , Microscopía Electrónica de Rastreo , PolímerosRESUMEN
Decreasing rates of ovulation, hormonal changes, and increasing bone loss pre-date menopause by several years. Data suggest that, in addition to estradiol, progesterone may play a significant role in the interrelationship between the ovaries and the skeleton in women. Indeed, the differentiation of human osteoblasts from perimenopausal women has been shown to be dose-dependent on progesterone at physiological concentrations. Data from a pilot study in perimenopasual women also suggested that higher progesterone levels, as seen in the luteal phase of ovulatory cycles, may be associated with more bone formation and with slightly less bone resorption than anovulatory cycles in which progesterone levels are low (< 5.8 ng/ml). These data led to the initiation of a large, prospective, 2-year observational study in perimenopausal women (the PEKNO study). Interim data from the PEKNO study indicate that a decrease in ovulation correlated with an increase in the loss of bone mineral density (BMD). A meta-analysis estimated a BMD increase of 0.5% per year in women with normal ovulation, and a BMD decrease of 0.7% per year in young women with ovulatory disturbances (anovulation or short luteal phase). A meta-analysis in postmenopausal women demonstrated a 1.3% increase per year in BMD when receiving hormone replacement therapy with unopposed estrogens, and a further 0.4% increase in BMD in women receiving estrogens plus progestogens. The role of progesterone in bone metabolism in perimenopausal women who are estrogen-replete requires further study.
Asunto(s)
Densidad Ósea/efectos de los fármacos , Terapia de Reemplazo de Estrógeno/métodos , Osteoporosis Posmenopáusica/inducido químicamente , Progesterona/administración & dosificación , Terapia de Reemplazo de Estrógeno/efectos adversos , Femenino , Humanos , Progesterona/efectos adversosRESUMEN
Neovascular pathologies in the eye like age-related macular degeneration (AMD), the diabetic retinopathie (DR), retinopathie of prematurity (ROP) or the retinal vein occlusion (RVO) are caused through a hypoxia induced upregulation of the vascular endothelial growth factor (VEGF). So far a correlation of intraocular VEGF concentrations to the impact of the pathologies is limited because of invasive sampling. Therefore, a minimally invasive, repeatable quantification of VEGF levels in the eye is needed to correlate the stage of VEGF induced pathologies as well as the efficacy of anti-VEGF treatment. Here we describe the development of three variants of enhanced BRET2 (eBRET2) based, single molecule biosensors by fusing a Renilla luciferase mutant with enhanced light output (RLuc8) to the N-terminus and a suitable eBRET2 acceptor fluorophore (GFP2) to the C-terminus of a VEGF binding domain, directly fused or separated with two different peptide linkers for the quantification of VEGF in vitro. The VEGF binding domain consists of a single chain variable fragment (scFv) based on ranibizumab in which the light- and the heavy- F(ab) chains were connected with a peptide linker to generate one open reading frame (orf). All three variants generate measureable eBRET2 ratios by transferring energy from the luciferase donor to the GFP2 acceptor, whereas only the directly fused and the proline variant permit VEGF quantification. The directly fused biosensor variant allows the quantification of VEGF with higher sensitivity, compared to the widely used ELISA systems and a wide dynamic quantification range in vitro. Our system demonstrates not only an additional in vitro application on VEGF quantification but also a promising step towards an applicable biosensor in an implantable device able to quantify VEGF reliably after implantation in vivo.
Asunto(s)
Técnicas Biosensibles/instrumentación , Transferencia Resonante de Energía de Fluorescencia/instrumentación , Mediciones Luminiscentes/instrumentación , Imagen Molecular/instrumentación , Ranibizumab/química , Factor A de Crecimiento Endotelial Vascular/análisis , Diseño de Equipo , Análisis de Falla de Equipo , Sondas Moleculares/química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factor A de Crecimiento Endotelial Vascular/químicaRESUMEN
An easy-to construct, easy-to-operate standardized system was developed for determining the residual biological contamination of surgical instruments, endoscopes and other medical appliances subjected to hospital cleansing and/or disinfection. It consists of standard-sized pieces of glass, metal or endoscope plastic--dirt carriers--either bare or enclosed in truncated Eppendorf caps to simulate hard-to-access conditions. The surface of the carriers is covered with model dirt simulating biological contamination and the carriers are then affixed to sturdy metal holders. Conventional model dirt were found to peel or flake off the carrier surface, lowering the precision of residual soil determination. A newly developed model dirt consisting of liver mash, lactose and sunflower oil and exhibiting low tendency to peel off surfaces was therefore used. The whole setup was subjected to chemical or enzymic cleansing programs at elevated temperature in hospital washer-disinfectors of two types, and the residual dirt after cleansing was determined by three methods. The method using toxicant-doped dirt that quenches the luminescence of an indicator bacterium Photobacterium phosphoreum gave satisfactory data under laboratory conditions but with hospital-washed samples it exhibited excessive fluctuations caused by bacterium--dirt interactions and by physical influences. Both other methods gave better results but displayed some process sensitivity. The luciferin-luciferase-based ATP bioluminescence assay sometimes gave low or even negative dirt level values and showed a low effect of reduced dirt accessibility on cleansing of metal carriers. The Bradford protein assay showed about equal cleansing efficiency for both easily and poorly accessible carriers after enzymic cleansing. Our system can be used for determining low levels of residual contamination of medical appliances after cleansing/disinfection and assessing the efficiency of commercial washer-disinfectors; its efficiency can be further increased by using a cleansing process-insensitive method for soil detection and quantification.
Asunto(s)
Desinfección/instrumentación , Desinfección/normas , Endoscopios , Contaminación de Equipos , Equipos y Suministros de Hospitales , Instrumentos Quirúrgicos , Adenosina Trifosfato , Detergentes , Desinfección/métodos , Calor , Luciferasas/metabolismo , Mediciones Luminiscentes , PhotobacteriumRESUMEN
The reduction of modifiable risk factors in hyperlipidemic patients with coronary heart disease (CHD) receiving standard medical care in Germany has not been evaluated before. We identified all patients < 65 yrs of age with marked hyperlipidemia (Cholesterol (Chol) > 250 mg/dl, HDL < 20% Chol) among all patients who underwent PTCA during defined periods 1991/92 in the Cardiology department of the Heinrich-Heine-University. The study patients (n = 93, age 54 +/- 8 yrs, 75 men, 18 women) were evaluated 13 +/- 2 months after PTCA for modification of their risk factors, treatments, knowledge, medications and dietary habits with a structured questionnaire and a 5-day dietary protocol. At follow-up Chol and LDL were significantly reduced from 299 +/- 47 to 253 +/- 43, and from 228 +/- 47 to 189 +/- 42 mg/dl, respectively (p < 0.001). 10% of patients had an LDL < 135 mg/dl. In contrast, HDL (43 +/- 9 mg/dl) and triglycerides (242 +/- 138 mg/dl), the percentage of smokers (40%), of overweight patients (38%) and of patients with elevated blood pressure (43%) remained unchanged. During the observation period the number of contacts with physicians was high (12 (1-40)). 32% of patients participated in dietary counselling by a dietician and 42% in an in-patient rehabilitation programme. In 2/3 of patients the knowledge related to hyperlipidemia and a lipid-lowering diet was good. However, according to the dietary protocols the fat intake was high (37 +/- 7% of total calories). Lipid lowering drugs had been prescribed in 68% of patients, predominantly as monotherapy and in low dosage.(ABSTRACT TRUNCATED AT 250 WORDS)