Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Radiology ; 311(2): e231921, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38805732

RESUMEN

Background Many clinically relevant fractures are occult on conventional radiographs and therefore challenging to diagnose reliably. X-ray dark-field radiography is a developing method that uses x-ray scattering as an additional signal source. Purpose To investigate whether x-ray dark-field radiography enhances the depiction of radiographically occult fractures in an experimental model compared with attenuation-based radiography alone and whether the directional dependence of dark-field signal impacts observer ratings. Materials and Methods Four porcine loin ribs had nondisplaced fractures experimentally introduced. Microstructural changes were visually verified using high-spatial-resolution three-dimensional micro-CT. X-ray dark-field radiographs were obtained before and after fracture, with the before-fracture scans serving as control images. The presence of a fracture was scored by three observers using a six-point scale (6, surely; 5, very likely; 4, likely; 3, unlikely; 2, very unlikely; and 1, certainly not). Differences between scores based on attenuation radiographs alone (n = 96) and based on combined attenuation and dark-field radiographs (n = 96) were evaluated by using the DeLong method to compare areas under the receiver operating characteristic curve. The impact of the dark-field signal directional sensitivity on observer ratings was evaluated using the Wilcoxon test. The dark-field data were split into four groups (24 images per group) according to their sensitivity orientation and tested against each other. Musculoskeletal dark-field radiography was further demonstrated on human finger and foot specimens. Results The addition of dark-field radiographs was found to increase the area under the receiver operating characteristic curve to 1 compared with an area under the receiver operating characteristic curve of 0.87 (95% CI: 0.80, 0.94) using attenuation-based radiographs alone (P < .001). There were similar observer ratings for the four different dark-field sensitivity orientations (P = .16-.65 between the groups). Conclusion These results suggested that the inclusion of dark-field radiography has the potential to help enhance the detection of nondisplaced fractures compared with attenuation-based radiography alone. © RSNA, 2024 See also the editorial by Rubin in this issue.


Asunto(s)
Estudios de Factibilidad , Animales , Porcinos , Microtomografía por Rayos X/métodos , Fracturas de las Costillas/diagnóstico por imagen , Fracturas Cerradas/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos
2.
Eur Radiol ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38488971

RESUMEN

OBJECTIVES: To develop an algorithm to link undiagnosed patients to previous patient histories based on radiographs, and simultaneous classification of multiple bone tumours to enable early and specific diagnosis. MATERIALS AND METHODS: For this retrospective study, data from 2000 to 2021 were curated from our database by two orthopaedic surgeons, a radiologist and a data scientist. Patients with complete clinical and pre-therapy radiographic data were eligible. To ensure feasibility, the ten most frequent primary tumour entities, confirmed histologically or by tumour board decision, were included. We implemented a ResNet and transformer model to establish baseline results. Our method extracts image features using deep learning and then clusters the k most similar images to the target image using a hash-based nearest-neighbour recommender approach that performs simultaneous classification by majority voting. The results were evaluated with precision-at-k, accuracy, precision and recall. Discrete parameters were described by incidence and percentage ratios. For continuous parameters, based on a normality test, respective statistical measures were calculated. RESULTS: Included were data from 809 patients (1792 radiographs; mean age 33.73 ± 18.65, range 3-89 years; 443 men), with Osteochondroma (28.31%) and Ewing sarcoma (1.11%) as the most and least common entities, respectively. The dataset was split into training (80%) and test subsets (20%). For k = 3, our model achieved the highest mean accuracy, precision and recall (92.86%, 92.86% and 34.08%), significantly outperforming state-of-the-art models (54.10%, 55.57%, 19.85% and 62.80%, 61.33%, 23.05%). CONCLUSION: Our novel approach surpasses current models in tumour classification and links to past patient data, leveraging expert insights. CLINICAL RELEVANCE STATEMENT: The proposed algorithm could serve as a vital support tool for clinicians and general practitioners with limited experience in bone tumour classification by identifying similar cases and classifying bone tumour entities. KEY POINTS: • Addressed accurate bone tumour classification using radiographic features. • Model achieved 92.86%, 92.86% and 34.08% mean accuracy, precision and recall, respectively, significantly surpassing state-of-the-art models. • Enhanced diagnosis by integrating prior expert patient assessments.

3.
Skeletal Radiol ; 53(7): 1319-1332, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38240761

RESUMEN

OBJECTIVE: To qualitatively and quantitatively evaluate the 2.5-year MRI outcome after Matrix-associated autologous chondrocyte implantation (MACI) at the patella, reconstruction of the medial patellofemoral ligament (MPFL), and combined procedures. METHODS: In 66 consecutive patients (age 22.8 ± 6.4years) with MACI at the patella (n = 16), MPFL reconstruction (MPFL; n = 31), or combined procedures (n = 19) 3T MRI was performed 2.5 years after surgery. For morphological MRI evaluation WORMS and MOCART scores were obtained. In addition quantitative cartilage T2 and T1rho relaxation times were acquired. Several clinical scores were obtained. Statistical analyses included descriptive statistics, Mann-Whitney-U-tests and Pearson correlations. RESULTS: WORMS scores at follow-up (FU) were significantly worse after combined procedures (8.7 ± 4.9) than after isolated MACI (4.3 ± 3.6, P = 0.005) and after isolated MPFL reconstruction (5.3 ± 5.7, P = 0.004). Bone marrow edema at the patella in the combined group was the only (non-significantly) worsening WORMS parameter from pre- to postoperatively. MOCART scores were significantly worse in the combined group than in the isolated MACI group (57 ± 3 vs 88 ± 9, P < 0.001). Perfect defect filling was achieved in 26% and 69% of cases in the combined and MACI group, respectively (P = 0.031). Global and patellar T2 values were higher in the combined group (Global T2: 34.0 ± 2.8ms) and MACI group (35.5 ± 3.1ms) as compared to the MPFL group (31.1 ± 3.2ms, P < 0.05). T2 values correlated significantly with clinical scores (P < 0.005). Clinical Cincinnati scores were significantly worse in the combined group (P < 0.05). CONCLUSION: After combined surgery with patellar MACI and MPFL reconstruction inferior MRI outcomes were observed than after isolated procedures. Therefore, patients with need for combined surgery may be at particular risk for osteoarthritis.


Asunto(s)
Imagen por Resonancia Magnética , Rótula , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Femenino , Resultado del Tratamiento , Rótula/diagnóstico por imagen , Rótula/cirugía , Adulto , Condrocitos/trasplante , Trasplante Autólogo , Adulto Joven , Articulación Patelofemoral/diagnóstico por imagen , Articulación Patelofemoral/cirugía , Procedimientos de Cirugía Plástica/métodos , Ligamentos Articulares/diagnóstico por imagen , Ligamentos Articulares/cirugía , Adolescente
4.
Acad Radiol ; 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38448326

RESUMEN

RATIONALE AND OBJECTIVES: To determine the diagnostic accuracy and reproducibility of conventional MR imaging (MRI) of the shoulder in evaluating biceps pulley lesions using arthroscopy as the standard of reference. METHODS: In a retrospective study, MR examinations of 68 patients with arthroscopically proven torn or intact biceps pulley were assessed for the presence of pulley lesions by three radiologists. The following criteria were evaluated: displacement of the long head of the biceps tendon (LHBT) relative to the subscapularis tendon (displacement sign), subluxation/dislocation of the LHBT, the integrity of the superior glenohumeral ligament (SGHL) and the coracohumeral ligament (CHL), lesions of the supraspinatus (SSP) and subscapularis (SSC) tendons adjacent to the rotator interval, presence of biceps tendinopathy and subacromial bursitis. RESULTS: There were 42 patients with pulley lesions in the study group. Conventional MR imaging showed an overall sensitivity of 95.2%, 88.1% and 92.9%, a specificity of 61.5%, 73.1%, and 80.8% and an accuracy of 82.4%, 82.4% and 88.2% in the diagnosis of pulley lesions. Interobserver agreement was substantial (multirater k = 0.75). Biceps tendinopathy (97.6%, 95.2%, 97.6%), defects of the SGHL (86.3%, 81.0%, 88.1%) and the displacement sign (88.1%, 81.0%, 85.7%) were the most sensitive diagnostic criteria. Subluxation/dislocation of the LHBT was insensitive (78.6%, 42.9%, 33.3%), but specific (69.2%, 100,0%, 96.2%). CONCLUSION: In the diagnosis of pulley lesions, conventional MR imaging is reproducible and shows high sensitivity and accuracy but moderate specificity.

5.
Eur Radiol Exp ; 8(1): 58, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38735899

RESUMEN

BACKGROUND: Chondrosarcomas are rare malignant bone tumors diagnosed by analyzing radiological images and histology of tissue biopsies and evaluating features such as matrix calcification, cortical destruction, trabecular penetration, and tumor cell entrapment. METHODS: We retrospectively analyzed 16 cartilaginous tumor tissue samples from three patients (51-, 54-, and 70-year-old) diagnosed with a dedifferentiated chondrosarcoma at the femur, a moderately differentiated chondrosarcoma in the pelvis, and a predominantly moderately differentiated chondrosarcoma at the scapula, respectively. We combined a hematein-based x-ray staining with high-resolution three-dimensional (3D) microscopic x-ray computed tomography (micro-CT) for nondestructive 3D tumor assessment and tumor margin evaluation. RESULTS: We detected trabecular entrapment on 3D micro-CT images and followed bone destruction throughout the volume. In addition to staining cell nuclei, hematein-based staining also improved the visualization of the tumor matrix, allowing for the distinction between the tumor and the bone marrow cavity. The hematein-based staining did not interfere with further conventional histology. There was a 5.97 ± 7.17% difference between the relative tumor area measured using micro-CT and histopathology (p = 0.806) (Pearson correlation coefficient r = 0.92, p = 0.009). Signal intensity in the tumor matrix (4.85 ± 2.94) was significantly higher in the stained samples compared to the unstained counterparts (1.92 ± 0.11, p = 0.002). CONCLUSIONS: Using nondestructive 3D micro-CT, the simultaneous visualization of radiological and histopathological features is feasible. RELEVANCE STATEMENT: 3D micro-CT data supports modern radiological and histopathological investigations of human bone tumor specimens. It has the potential for being an integrative part of clinical preoperative diagnostics. KEY POINTS: • Matrix calcifications are a relevant diagnostic feature of bone tumors. • Micro-CT detects all clinically diagnostic relevant features of x-ray-stained chondrosarcoma. • Micro-CT has the potential to be an integrative part of clinical diagnostics.


Asunto(s)
Neoplasias Óseas , Condrosarcoma , Estudios de Factibilidad , Imagenología Tridimensional , Microtomografía por Rayos X , Humanos , Condrosarcoma/diagnóstico por imagen , Condrosarcoma/patología , Microtomografía por Rayos X/métodos , Anciano , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/patología , Persona de Mediana Edad , Estudios Retrospectivos , Imagenología Tridimensional/métodos , Masculino , Femenino , Coloración y Etiquetado/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA