Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Surg Res ; 232: 1-6, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30463704

RESUMEN

BACKGROUND: The purpose of this study is to compare the ablation performance between a synchronous microwave ablation (MWA) system and a commercially available asynchronous system in ex vivo bovine liver and evaluate the efficacy of ablation at varying entrance angles. MATERIALS AND METHODS: Two 915-MHz MWA systems were used in bench top ex vivo bovine livers with various conditions (synchronous versus asynchronous). Using synchronous technology ablations to liver, kidney, or lung at angles of 0, 15, 30, and 90° were evaluated. RESULTS: Synchronous and asynchronous MWA systems created mean ablation zone volumes of 26.4 and 15.8 cm3, 62.9 and 45.4 cm3, 90.8 and 56.4, and 75.7 and 54.8 cm3 with single, double (2 microwave probes in use simultaneous) (2 cm spacing), and triple (three probes in use simultaneously) (2 cm and 3 cm spacing) antennae configurations, respectively; adjusted P-values ≤ 0.006. Ablation defects were similar across all groups when evaluated for entrance angle. Specifically, when comparing 0-degree angle to all other angles, achieved zones of ablation (ZA) were similar (mean ± standard deviation for 0-degree versus all other angles: 8.72 ± 4.84 versus 9.38 ± 4.11 cm2, P = 0.75). The use of the long-tip probe resulted in a statistically significant increase in the achieved ZA when compared to the short tip probe (10.9 ± 4.3 versus 6.5 ± 2.4, respectively; P = 0.01). CONCLUSIONS: Newly developed synchronous microwave technology creates significantly larger ablation zones when compared to an existing asynchronous commercially available system. The angle of approach does not affect the resulting ZA. This is clinically relevant as true 0-degree angle is often difficult to obtain.


Asunto(s)
Ablación por Catéter/métodos , Microondas/uso terapéutico , Animales , Porcinos
2.
Radiology ; 262(1): 353-60, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22106348

RESUMEN

PURPOSE: To determine histologic changes induced by microwave ablation (MWA) in patients with pulmonary malignancy by using an ablation system with tumor permittivity feedback control, enabling real-time modulation of energy power and frequency. MATERIALS AND METHODS: Institutional review board approval and patient informed consent were obtained for this prospective HIPAA-complaint ablation and resection study. Between March 2009 and January 2010, 10 patients (four women, six men; mean age, 71 years; age range, 52-82 years) underwent intraoperative MWA of pulmonary malignancies. Power (10-32 W) and frequency (908-928 MHz) were continuously adjusted by the generator to maintain a temperature of 110°-120°C at the 14-gauge antenna tip for one 10-minute application. After testing for an air leak, tumors were resected surgically. Gross inspection, slicing, and hematoxylin-eosin (10 specimens) and nicotinamide adenine dinucleotide (six specimens) staining were performed. RESULTS: Tumors included adenocarcinomas (n = 5), squamous cell carcinomas (n = 3), and metastases from endometrial (n = 1) and colorectal (n = 1) primary carcinomas. Mean maximum tumor diameter was 2.4 cm (range, 0.9-5.0 cm), and mean maximum volume was 8.6 cm(3) (range, 0.5-52.7 cm(3)). One air leak was detected. Five of 10 specimens were grossly measurable, revealing a mean maximum ablation zone diameter of 4.8 cm (range, 3.0-6.5 cm) and a mean maximum ablation zone volume of 15.1 cm(3) (range, 7.3-25.1 cm(3)). At hematoxylin-eosin staining, coagulation necrosis was observed in all ablation zones, extended into the normal lung in nine of 10 specimens, and up to blood vessel walls without evidence of vessel (>4 mm) thrombosis. Nicotinamide adenine dinucleotide staining enabled confirmation of no viability within ablation zones extending into normal lung in five of six specimens. CONCLUSION: MWA with tumor permittivity feedback control results in cytotoxic intratumoral temperatures and extension of ablation zones into aerated peritumoral pulmonary parenchyma, possibly forming the equivalent of an oncologic resection margin.


Asunto(s)
Ablación por Catéter/métodos , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Anciano , Anciano de 80 o más Años , Biopsia , Retroalimentación , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía de Emisión de Positrones , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
3.
AJR Am J Roentgenol ; 197(3): 671-5, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21862810

RESUMEN

OBJECTIVE: The objective of our study was to report the incidence of multiple sporadic primary renal cell carcinomas (RCCs) in patients referred for radiofrequency ablation (RFA). MATERIALS AND METHODS: A retrospective search identified 162 patients (104 men and 58 women; mean age, 74 years) without a history of von Hippel-Lindau disease with a total of 175 tumors treated with RFA for biopsy-proven primary renal malignancies at our institution from 1998 to 2009. Three groups of patients with multiple RCCs were identified: patients with a history of nephrectomy for RCC who had been referred for RFA of a new renal tumor, patients who presented with multiple renal tumors at the time of referral for RFA, and patients who were shown to have developed a new renal tumor on follow-up imaging after RFA. RESULTS: Twenty-eight patients (17%) had multiple biopsy-proven RCCs. Eighteen patients (11%) had undergone prior nephrectomy for surgically proven RCC. The mean interval between prior nephrectomy and RFA referral was 122 months (range, 12-456 months). Seven patients (4%) without a history of nephrectomy presented with two biopsy-proven RCCs at RFA referral. Three patients (2%) who had not undergone nephrectomy and had a solitary RCC at the time of RFA had developed a new biopsy-proven RCC separate from the original treatment site on follow-up imaging after RFA. The mean time to diagnosis from the initial RFA treatment was 52 months (range, 25-89 months). CONCLUSION: Imaging surveillance of patients referred for renal RFA may be important not only to assess treatment success but also to detect new RCCs.


Asunto(s)
Carcinoma de Células Renales/cirugía , Ablación por Catéter/métodos , Neoplasias Renales/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/epidemiología , Medios de Contraste , Femenino , Humanos , Incidencia , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/epidemiología , Masculino , Persona de Mediana Edad , Nefrectomía , Reoperación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
Radiology ; 247(3): 871-9, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18372457

RESUMEN

PURPOSE: To retrospectively evaluate effectiveness, follow-up imaging features, and safety of microwave ablation in 50 patients with intraparenchymal pulmonary malignancies. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board; informed consent was waived. From November 10, 2003, to August 28, 2006, 82 masses (mean, 1.42 per patient) in 50 patients (28 men, 22 women; mean age, 70 years) were percutaneously treated in 66 microwave ablation sessions. Each tumor was ablated with computed tomographic (CT) guidance. Follow-up contrast material-enhanced CT and positron emission tomographic (PET) scans were reviewed. Mixed linear modeling and logistic regression were performed. Time-event data were analyzed (Kaplan-Meier survival estimates and log-rank statistic). All event times were the time to a patient's first event (alpha level = .05, all analyses). RESULTS: At follow-up (mean, 10 months), 26% (13 of 50) of patients had residual disease at the ablation site, predicted by using index size of larger than 3 cm (P = .01). Another 22% (11 of 50) of patients had recurrent disease resulting in a 1-year local control rate of 67%, with mean time to first recurrence of 16.2 months. Kaplan-Meier analysis yielded an actuarial survival of 65% at 1 year, 55% at 2 years, and 45% at 3 years from ablation. Cancer-specific mortality yielded a 1-year survival of 83%, a 2-year survival of 73%, and a 3-year survival of 61%; these values were not significantly affected by index size of larger than 3 cm or 3 cm or smaller or presence of residual disease. Cavitation (43% [35 of 82] of treated tumors) was associated with reduced cancer-specific mortality (P = .02). Immediate complications included pneumothorax (Common Terminology Criteria for Adverse Events [CTCAE] grades 1 [18 of 66 patients] and 2 [eight of 66 patients]), hemoptysis (four of 66 patients), and skin burns (CTCAE grades 2 [one of 66 patients] and 3 [one of 66 patients]). CONCLUSION: Microwave ablation is effective and may be safely applied to lung tumors. (c) RSNA, 2008.


Asunto(s)
Ablación por Catéter/instrumentación , Neoplasias Pulmonares/cirugía , Microondas/uso terapéutico , Tomografía Computarizada por Rayos X , Anciano , Medios de Contraste , Femenino , Humanos , Modelos Lineales , Modelos Logísticos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
5.
Eur J Radiol ; 84(6): 1083-90, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25818732

RESUMEN

PURPOSE: To retrospectively evaluate the safety and efficacy of microwave ablation (MWA) as treatment for single, focal hepatic malignancies. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study. From December 2003 to May 2012, 64 patients were treated with MWA for a single hepatic lesion, in 64 sessions. Hepatocellular carcinoma (HCC) was treated in 25 patients (geometric mean tumor size, 3.33-cm; 95% CI, 2.65-4.18-cm; range, 1.0-12.0-cm), metastatic colorectal cancer (CRC) was treated in 27 patients (geometric mean tumor size, 2.7-cm; 95% CI, 2.20-3.40-cm; range, 0.8-6.0-cm), and other histological-types were treated in 12 patients (geometric mean tumor size, 3.79-cm; 95% CI, 2.72-5.26-cm; range, 1.7-8.0-cm). Kaplan-Meier (K-M) method was used to analyze time event data. Chi-square and correlation evaluated the relationship between tumor size and treatment parameters. RESULTS: Technical success rate was 95.3% (61/64). Treatment parameters were tailored to tumor size; as size increased more antennae were used (p<0.001), treatment with multiple activations increased (p<0.028), and treatment time increased (p<0.001). There was no statistically significant relationship between time to recurrence and tumor size, number of activations, number of antennae, and treatment time. At one-year, K-M analysis predicted a likelihood of local recurrence of 39.8% in HCC patients, 45.7% in CRC metastases patients, and 70.8% in patients with other metastases. Median cancer specific survivals for patients were 38.3 months for HCC patients, 36.3 months for CRC metastases, and 13.9 months for other histological-types. Complications occurred in 23.4% (15/64) of sessions. CONCLUSION: In our sample, tumor size did not appear to impact complete ablation rates or local recurrence rates for focal hepatic malignancies treated with MWA.


Asunto(s)
Técnicas de Ablación/métodos , Carcinoma Hepatocelular/cirugía , Neoplasias Hepáticas/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Microondas , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
7.
Eur J Radiol ; 81(8): 1717-23, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21636231

RESUMEN

PURPOSE: To retrospectively evaluate the effectiveness and safety of image-guided ablation of adrenal tumors. MATERIALS AND METHODS: : This HIPAA-compliant study was IRB approved and informed consent was waived. From 5/1999-6/2008, 20 consecutive adrenal metastases (mean diameter 4.2cm; range, 2-8) and 3 hormonally active primary adrenal tumors (mean diameter 2.3cm; range, 1-4), including an aldosteronoma and 2 pheochromocytomas in 22 patients (14 men, 8 women; mean age 61 years; range 40-84) were ablated in 23 sessions. Bilateral metastases were treated in a single patient. Radiofrequency ablation was used to treat 16 adrenal metastases and the 3 hyperfunctioning tumors. Microwave ablation was used to treat 4 metastases. Successful treatment was defined as a lack of both enhancement on follow-up contrast enhanced CT and/or up-take on FDG PET-CT and for functioning tumors, resolution of biochemical abnormalities. RESULTS: Technical success was achieved in all sessions. Mean follow-up was 45.1 months (range, 1-91) Local tumor progression (focal enhancement at ablation site ≥1cm in short axis) was detected in 4 of 23 tumors, two of which were identified bilaterally in a single patient prompting re-treatment. Of 19 patients with metastatic disease, 16 had fatal extra-adrenal disease progression, and 3 remain alive. Two of the 3 patients who underwent ablation of hyperfunctioning tumors remain alive, including the patient with an aldosteronoma who had recurrent symptoms 91 months post ablation. Intra-ablative hypertension occurred in 9% (2/23) of sessions and was successfully treated pharmacologically. CONCLUSION: Ablation of metastatic and hyperfunctioning adrenal tumors is safe and may provide local control and treatment of pathologic biochemical activity.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/cirugía , Adrenalectomía/métodos , Ablación por Catéter/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adrenalectomía/efectos adversos , Adulto , Anciano , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA