Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Hong Kong Med J ; 28(6): 475-481, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35815480

RESUMEN

INTRODUCTION: Kidney cancer, primarily renal cell carcinoma (RCC), ranks among the top 10 most common malignancies in the male population of Hong Kong. In 2019, members of two medical societies in Hong Kong formed an expert panel to establish a set of consensus statements for the management of metastatic RCC. On 22 June 2021, the same panel met to review recent evidence and reassess their positions regarding the management of advanced and metastatic RCC, with the aim of providing recommendations for physicians in Hong Kong. PARTICIPANTS: The panel included 12 experts (6 clinical oncologists and 6 urologists) who had extensive experience managing patients with RCC in Hong Kong. EVIDENCE: The panel reviewed randomised controlled trials, observational studies, systematic reviews/meta-analyses, and international clinical guidelines to address key clinical questions that were identified before the meeting. CONSENSUS PROCESS: In total, 15 key clinical questions were identified before the meeting, covering the surgical and systemic treatment of advanced or metastatic clear cell, sarcomatoid, and non-clear cell RCCs. At the meeting, the panellists voted on these questions, then discussed relevant evidence and practical considerations. CONCLUSIONS: The treatment landscape for advanced and metastatic RCC continues to evolve. More immune checkpoint inhibitor (ICI)-based combination regimens will be indicated for the treatment of metastatic clear cell RCC. There is increasing evidence concerning the benefit of adjuvant ICI treatment for resected advanced RCC. This article summarises recent evidence and expert insights regarding a series of key clinical questions about the management of advanced and metastatic RCC.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Humanos , Masculino , Carcinoma de Células Renales/terapia , Neoplasias Renales/terapia , Hong Kong/epidemiología , Consenso , Sociedades Médicas
2.
Hong Kong Med J ; 25(1): 13-20, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30655460

RESUMEN

INTRODUCTION: Lower urinary tract symptoms (LUTS) have a strong effect on socio-economic and individual quality of life. The aim of the present study was to investigate the prevalence of LUTS in an Asian population. METHODS: A telephone survey of individuals aged ≥40 years and of Chinese ethnicity was conducted. The survey included basic demographics, medical and health history, drinking habits, International Prostate Symptom Score, overactive bladder symptom score, Patient Health Questionnaire (PHQ-9) score, and Short Form (SF)-12v2 score. RESULTS: From March to May 2017, 18 881 calls were made, of which 1543 fulfilled the inclusion criteria. In the end, 1000 successful respondents were recruited (302 men and 698 women). Age-adjusted prevalence of overactive bladder syndrome was 15.1%. The older the respondent, the more prevalent the storage symptoms and voiding symptoms (storage symptoms: r=0.434, P<0.001; voiding symptom: r=0.190, P<0.001). Presence of hypertension and diabetes were found to be significantly and positively correlated with storage and voiding symptoms. Storage and voiding symptoms were found to affect PHQ-9 scores (storage symptoms: r=0.257, P<0.001; voiding symptoms: r=0.275, P<0.001) and SF-12v2 scores (storage symptoms: r=0.467, P<0.001; voiding symptoms: r=0.335; P<0.001). Nocturia was the most prominent symptom among patients who sought medical help for their LUTS. CONCLUSIONS: Lower urinary tract symptoms are common in Asian populations. Both storage and voiding symptoms have a negative impact on mental health and general well-being of individuals.


Asunto(s)
Síntomas del Sistema Urinario Inferior/epidemiología , Nocturia/epidemiología , Vejiga Urinaria Hiperactiva/epidemiología , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Femenino , Hong Kong/epidemiología , Humanos , Modelos Logísticos , Síntomas del Sistema Urinario Inferior/diagnóstico , Masculino , Persona de Mediana Edad , Nocturia/diagnóstico , Población , Prevalencia , Calidad de Vida , Índice de Severidad de la Enfermedad , Distribución por Sexo , Encuestas y Cuestionarios , Teléfono , Vejiga Urinaria Hiperactiva/diagnóstico
3.
Eur Radiol ; 26(1): 79-86, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26002131

RESUMEN

OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.


Asunto(s)
Angiografía Cerebral/métodos , Cristalino/efectos de la radiación , Embolización Terapéutica/métodos , Diseño de Equipo , Femenino , Fluoroscopía/métodos , Humanos , Aneurisma Intracraneal/terapia , Masculino , Persona de Mediana Edad , Dosis de Radiación , Radiografía Intervencional/métodos
4.
J Appl Clin Med Phys ; 14(4): 4182, 2013 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-23835383

RESUMEN

Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek ScanMaker 9800XL scanner and the subsequent use in the dosimetric verification of a 3D conformal radiotherapy treatment. The film reproducibility and scanner uniformity of the Microtek ScanMaker 9800XL was studied. A three-field 3D conformal radiotherapy treatment was planned on an anthropomorphic phantom and EBT2 film measurements were carried out to verify the treatment. The interfilm reproducibility was found to be 0.25%. Over a period of three months, the films darkened by 1%. The scanner reproducibility was ± 2% and a nonuniformity was ±1.9% along the direction perpendicular to the scan direction. EBT2 measurements showed an underdose of 6.2% at high-dose region compared to TPS predicted dose. This may be due to the inability of the treatment planning system to predict the correct dose distribution in the presence of tissue inhomogeneities and the uncertainty of the scanner reproducibility and uniformity. The use of EBT2 film in conjunction with the axial CT image of the anthropomorphic phantom allows the evaluation of the anatomical location of dose discrepancies between the EBT2 measured dose distribution and TPS predicted dose distribution.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia Conformacional/normas , Película para Rayos X , Calibración , Humanos , Imagenología Tridimensional , Fantasmas de Imagen , Control de Calidad , Radiometría/instrumentación , Radiometría/normas , Dosificación Radioterapéutica , Reproducibilidad de los Resultados
5.
AJNR Am J Neuroradiol ; 44(6): 634-640, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37169541

RESUMEN

BACKGROUND AND PURPOSE: Surgical clipping and endovascular treatment are commonly used in patients with unruptured intracranial aneurysms. We compared the safety and efficacy of the 2 treatments in a randomized trial. MATERIALS AND METHODS: Clipping or endovascular treatments were randomly allocated to patients with one or more 3- to 25-mm unruptured intracranial aneurysms judged treatable both ways by participating physicians. The study hypothesized that clipping would decrease the incidence of treatment failure from 13% to 4%, a composite primary outcome defined as failure of aneurysm occlusion, intracranial hemorrhage during follow-up, or residual aneurysms at 1 year, as adjudicated by a core lab. Safety outcomes included new neurologic deficits following treatment, hospitalization of >5 days, and overall morbidity and mortality (mRS > 2) at 1 year. There was no blinding. RESULTS: Two hundred ninety-one patients were enrolled from 2010 to 2020 in 7 centers. The 1-year primary outcome, ascertainable in 290/291 (99%) patients, was reached in 13/142 (9%; 95% CI, 5%-15%) patients allocated to surgery and in 28/148 (19%; 95% CI, 13%-26%) patients allocated to endovascular treatments (relative risk: 2.07; 95% CI, 1.12-3.83; P = .021). Morbidity and mortality (mRS >2) at 1 year occurred in 3/143 and 3/148 (2%; 95% CI, 1%-6%) patients allocated to surgery and endovascular treatments, respectively. Neurologic deficits (32/143, 22%; 95% CI, 16%-30% versus 19/148, 12%; 95% CI, 8%-19%; relative risk: 1.74; 95% CI, 1.04-2.92; P = .04) and hospitalizations beyond 5 days (69/143, 48%; 95% CI, 40%-56% versus 12/148, 8%; 95% CI, 5%-14%; relative risk: 0.18; 95% CI, 0.11-0.31; P < .001) were more frequent after surgery. CONCLUSIONS: Surgical clipping is more effective than endovascular treatment of unruptured intracranial aneurysms in terms of the frequency of the primary outcome of treatment failure. Results were mainly driven by angiographic results at 1 year.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Resultado del Tratamiento , Insuficiencia del Tratamiento , Procedimientos Endovasculares/métodos , Embolización Terapéutica/métodos
6.
Med Phys ; 39(5): 2544-58, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22559625

RESUMEN

PURPOSE: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf collimators to deliver highly modulated and complex radiation treatment. Dosimetric verification of the IMRT treatment requires the verification of the delivered dose distribution. Two dimensional ion chamber or diode arrays are gaining popularity as a dosimeter of choice due to their real time feedback compared to film dosimetry. This paper describes the characterization of a novel 2D diode array, which has been named the "magic plate" (MP). It was designed to function as a 2D transmission detector as well as a planar detector for dose distribution measurements in a solid water phantom for the dosimetric verification of IMRT treatment delivery. METHODS: The prototype MP is an 11 × 11 detector array based on thin (50 µm) epitaxial diode technology mounted on a 0.6 mm thick Kapton substrate using a proprietary "drop-in" technology developed by the Centre for Medical Radiation Physics, University of Wollongong. A full characterization of the detector was performed, including radiation damage study, dose per pulse effect, percent depth dose comparison with CC13 ion chamber and build up characteristics with a parallel plane ion chamber measurements, dose linearity, energy response and angular response. RESULTS: Postirradiated magic plate diodes showed a reproducibility of 2.1%. The MP dose per pulse response decreased at higher dose rates while at lower dose rates the MP appears to be dose rate independent. The depth dose measurement of the MP agrees with ion chamber depth dose measurements to within 0.7% while dose linearity was excellent. MP showed angular response dependency due to the anisotropy of the silicon diode with the maximum variation in angular response of 10.8% at gantry angle 180°. Angular dependence was within 3.5% for the gantry angles ± 75°. The field size dependence of the MP at isocenter agrees with ion chamber measurement to within 1.1%. In the beam perturbation study, the surface dose increased by 12.1% for a 30 × 30 cm(2) field size at the source to detector distance (SDD) of 80 cm whilst the transmission for the MP was 99%. CONCLUSIONS: The radiation response of the magic plate was successfully characterized. The array of epitaxial silicon based detectors with "drop-in" packaging showed properties suitable to be used as a simplified multipurpose and nonperturbing 2D radiation detector for radiation therapy dosimetric verification.


Asunto(s)
Radiometría/instrumentación , Radioterapia Asistida por Computador/instrumentación , Aire , Modelos Lineales , Fantasmas de Imagen , Dosificación Radioterapéutica , Radioterapia Asistida por Computador/efectos adversos , Propiedades de Superficie , Agua
7.
Med Phys ; 38(3): 1226-38, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21520835

RESUMEN

PURPOSE: Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. METHODS: The DMG is an array of 128 phosphor implanted n+ strips on a p-type Si wafer. The sensitive area defined by a single n+ strip is 20 x 2000 microm2. The Si wafer is 375 microm thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S(cp)) of the SRS cones. Comparisons were made with the EBT2 film and standard S(cp) values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. RESULTS: The dose per pulse dependency of the DMG was found to be < 5% for a dpp change of 7.5 times. The angular response of the detector was investigated in the azimuthal and polar directions. The maximum polar angular response was 13.8% at the gantry angle of 320 degrees, which may be partly due to the phantom geometry. The maximum azimuthal angular response was 15.3% at gantry angles of 90 degrees and 270 degrees. The angular response at the gantry angle of 180 degrees was 6.3%. A correction function was derived to correct for the angular dependence of the detector, which takes into account the contribution of the azimuthal and polar angular response at different treatment couch positions. The maximum positioning errors due to collimator, gantry, and couch rotation were 0.2 +/- 0.1, 0.4 +/- 0.1, and 0.4 +/- 0.2 mm, respectively. The SRS cone S(cp) agrees very well with the standard data with an average difference of 1.2 +/- 1.1%. Comparison of the relative intensity profiles of the DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. CONCLUSIONS: The DMG was investigated for dose per pulse and angular dependency. Its application to SRS/SRT delivery verification was demonstrated. The DMG with its high spatial resolution and real time capability allows measurement of dose profiles for cone applicators down to 5 mm in diameter, both accurately and rapidly as required in typical SRS/SRT deliveries.


Asunto(s)
Radiometría/instrumentación , Radiocirugia/métodos , Radiocirugia/normas , Silicio , Humanos , Control de Calidad , Reproducibilidad de los Resultados
8.
Med Phys ; 38(4): 2256-64, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21626960

RESUMEN

PURPOSE: Helical tomotherapy is a complex delivery technique, integrating CT image guidance and intensity modulated radiotherapy in a single system. The integration of the CT detector ring on the gantry not only allows patient position verification but is also often used to perform various QA procedures. This convenience lacks the rigor of a machine-independent QA process. METHODS: In this article, a Si strip detector, known as the Dose Magnifying Glass (DMG), was used to perform machine-independent QA measurements of the multileaf collimator alignment, leaf open time threshold, and leaf fluence output factor (LFOF). RESULTS: The DMG measurements showed good agreements with EDR2 film for the MLC alignment test while the CT detector agrees well with DMG measurements for leaf open time threshold and LFOF measurements. The leaf open time threshold was found to be approximately 20 ms. The LFOF measured with the DMG agreed within error with the CT detector measured LFOF. CONCLUSIONS: The DMG with its 0.2 mm spatial resolution coupled to TERA ASIC allowed real-time high temporal resolution measurements of the tomotherapy leaf movement. In conclusion, DMG was shown to be a suitable tool for machine-independent QA of a tomotherapy unit.


Asunto(s)
Vidrio , Dosis de Radiación , Radioterapia Asistida por Computador/instrumentación , Tomografía Computarizada por Rayos X , Control de Calidad , Dosificación Radioterapéutica , Radioterapia Asistida por Computador/normas , Silicio
9.
Can J Neurol Sci ; 38(3): 446-51, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21515504

RESUMEN

OBJECTIVE: Octogenarians were excluded from participation in many carotid endarterectomy trials due to the high complication rates observed in past studies. However, stroke resulting from carotid stenosis is expected to increase with the aging population. Moreover, advances in Carotid Angioplasty and Stenting (CAS) techniques have resulted in perceived improved safety of this procedure. We sought to review our experience with carotid stenting in symptomatic octogenarians with an emphasis on short-term outcomes and complications. METHODS: This is a retrospective longitudinal cohort study of all symptomatic patients who underwent CAS in our center between 1997 and 2007. Thirty-day stroke and death rates, and length of hospitalization were compared between the symptomatic octogenarians and non-octogenarians. RESULTS: A total of 214 procedures were performed on 211 symptomatic patients (56 females). Fifty-nine patients (14 females) were octogenarians. The median (interquartile range) age on procedure date for the octogenarian cohort was 83 (4) years. Periprocedural death occurred in two (3.4%) octogenarians and five (3.3%) non-octogenarians (p = 0.97). At 30 days from the procedure, stroke occurred in four (6.8%) octogenarians and seven (4.6%) non-octogenarians (p= 0.52). The mean hospital stay (4.8 days) was not different between the two cohorts. Age was not a predictor of the 30-day risk of composite stroke or death. CONCLUSION: The complications rate observed in octogenarians was not significantly higher than non-octogenarians. Our findings suggest that octogenarians should be included in randomized trials examining CAS to better define the risk-benefit profile of this procedure in the elderly.


Asunto(s)
Envejecimiento , Angioplastia/efectos adversos , Estenosis Carotídea/terapia , Endarterectomía Carotidea/efectos adversos , Stents/efectos adversos , Accidente Cerebrovascular/etiología , Anciano , Anciano de 80 o más Años , Distribución de Chi-Cuadrado , Estudios de Cohortes , Femenino , Humanos , Masculino , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Resultado del Tratamiento
12.
AJNR Am J Neuroradiol ; 42(1): 28-31, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33154074

RESUMEN

It is of utmost importance to avoid errors and subsequent complications when performing neurointerventional procedures, particularly when treating low-risk conditions such as unruptured intracranial aneurysms. We used endovascular treatment of unruptured intracranial aneurysms as an example and took a survey-based approach in which we reached out to 233 neurointerventionalists. They were asked what they think are the most important points staff should teach their trainees to avoid errors and subsequent complications in endovascular treatment of unruptured intracranial aneurysms. One hundred twenty-one respondents (51.9%) provided answers in the form of free text responses, which were thematically clustered in an affinity diagram and summarized in this Practice Perspectives. The article is primarily intended for neurointerventional radiology fellows and junior staff and will hopefully provide them the opportunity to learn from the mistakes of their more experienced colleagues.


Asunto(s)
Embolización Terapéutica/efectos adversos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/educación , Aneurisma Intracraneal/terapia , Procedimientos Neuroquirúrgicos/educación , Complicaciones Posoperatorias/prevención & control , Anciano , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Procedimientos Neuroquirúrgicos/efectos adversos , Complicaciones Posoperatorias/etiología , Encuestas y Cuestionarios
13.
Med Phys ; 37(2): 427-39, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20229851

RESUMEN

PURPOSE: Intensity modulated radiation therapy (IMRT) allows the delivery of escalated radiation dose to tumor while sparing adjacent critical organs. In doing so, IMRT plans tend to incorporate steep dose gradients at interfaces between the target and the organs at risk. Current quality assurance (QA) verification tools such as 2D diode arrays, are limited by their spatial resolution and conventional films are nonreal time. In this article, the authors describe a novel silicon strip detector (CMRP DMG) of high spatial resolution (200 microm) suitable for measuring the high dose gradients in an IMRT delivery. METHODS: A full characterization of the detector was performed, including dose per pulse effect, percent depth dose comparison with Farmer ion chamber measurements, stem effect, dose linearity, uniformity, energy response, angular response, and penumbra measurements. They also present the application of the CMRP DMG in the dosimetric verification of a clinical IMRT plan. RESULTS: The detector response changed by 23% for a 390-fold change in the dose per pulse. A correction function is derived to correct for this effect. The strip detector depth dose curve agrees with the Farmer ion chamber within 0.8%. The stem effect was negligible (0.2%). The dose linearity was excellent for the dose range of 3-300 cGy. A uniformity correction method is described to correct for variations in the individual detector pixel responses. The detector showed an over-response relative to tissue dose at lower photon energies with the maximum dose response at 75 kVp nominal photon energy. Penumbra studies using a Varian Clinac 21EX at 1.5 and 10.0 cm depths were measured to be 2.77 and 3.94 mm for the secondary collimators, 3.52 and 5.60 mm for the multileaf collimator rounded leaf ends, respectively. Point doses measured with the strip detector were compared to doses measured with EBT film and doses predicted by the Philips Pinnacle treatment planning system. The differences were 1.1% +/- 1.8% and 1.0% +/- 1.6%, respectively. They demonstrated the high temporal resolution capability of the detector readout system, which will allow one to investigate the temporal dose pattern of IMRT and volumetric modulated are therapy (VMAT) deliveries. CONCLUSIONS: The CMRP silicon strip detector dose magnifying glass interfaced to a TERA ASIC DAQ system has high spatial and temporal resolution. It is a novel and valuable tool for QA in IMRT dose delivery and for VMAT dose delivery.


Asunto(s)
Radiometría/instrumentación , Radioterapia Conformacional/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño Asistido por Computadora , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Silicio
14.
Can J Neurol Sci ; 37(5): 568-73, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21059500

RESUMEN

BACKGROUND: Although carotid endarterectomy is considered the 'gold standard' for standard risk symptomatic patients, the treatment of choice for asymptomatic patients remains controversial. Carotid stenting has demonstrated real-world outcomes consistent with established guidelines for carotid endarterectomy in asymptomatic high-surgical risk patients in recent prospective multicenter trials. We describe our experience with asymptomatic patients who underwent carotid stenting at our center in a routine clinical setting. METHODS: This is a retrospective, longitudinal cohort study of patients who underwent carotid angioplasty and stenting at the Foothills Medical Center, Calgary, Canada between 1997 and 2007. The qualifying events were categorized as symptomatic and asymptomatic. The procedures were performed by four experienced neurointerventionists. The primary outcome was stroke or death at 30-day follow- up. RESULTS: 243 patients underwent 255 carotid stenting procedures. Their ages ranged from 50 to 83 years; the mean age was 72.0 ± 9.3 years; 67(26.3%) were women. Forty one patients (16.1%) were asymptomatic; 214 patients (83.9%) were symptomatic. The patients in the asymptomatic group were significantly younger - 66.0 ± 8.8 years compared to patients in the symptomatic group 73.2 ± 8.9 years (p < 0.0001). Intraprocedurally one minor stroke (2.4%) occurred in the asymptomatic group. At 30-day follow-up, no deaths or further strokes were noted in the asymptomatic group; while eight deaths, six major and seven minor strokes occurred in the symptomatic group (p = 0.22). CONCLUSION: Carotid stenting appears to be a safe procedure in asymptomatic patients with severe carotid stenosis in routine clinical settings as witnessed in this single center study.


Asunto(s)
Estenosis Carotídea/epidemiología , Estenosis Carotídea/cirugía , Endarterectomía Carotidea/métodos , Anciano , Anciano de 80 o más Años , Canadá/epidemiología , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
15.
Environ Toxicol Pharmacol ; 27(3): 396-401, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-21783970

RESUMEN

In the present study, two antioxidant components (polysaccharopeptide complex P(1-a) and condensed tannin P(1-b)) from rose (Rosa rugosa) flowers were each incubated with mouse erythrocytes to investigate their effect on erythrocyte superoxide dismutase (SOD), and catalase (CAT) activities. It was found that the activities of Cu, Zn-SOD and CAT were markedly increased after incubation for 3h with rose flower fractions at the concentration of 500µg/ml. Similar changes were also observed in the erythrocyte gene expression of SOD and CAT. These results show that P(1-a) and P(1-b) are effective antioxidants that increase the activity and the gene expression of SOD and CAT in mouse erythrocytes.

16.
Radiat Prot Dosimetry ; 187(4): 451-460, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31650160

RESUMEN

This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reader accuracy, reproducibility, batch homogeneity, energy dependence and signal stability, were explored. The suitability of the nanoDot™ dosemeters was evaluated by measuring the depth dose curve, in vivo dose measurement and image perturbation. The nanoDot™ dosemeters were observed to produce a linear dose with ±2.8% coefficient variation. Significant batch inhomogeneity (8.3%) was observed. A slight energy dependence (±6.1%) was observed between 60 and 140 kVp. The InLight® microStar reader demonstrated good accuracy and a reproducibility of ±2%. The depth dose curve measured using nanoDot™ dosemeters showed slightly lower responses than Monte Carlo simulation results. The total uncertainty for a single dose measurement using this system was 11%, but it could be reduced to 9.2% when energy dependence correction was applied.


Asunto(s)
Método de Montecarlo , Dosimetría con Luminiscencia Ópticamente Estimulada/instrumentación , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Dosímetros de Radiación/normas , Radiografía/métodos , Calibración , Simulación por Computador , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados
17.
J Appl Microbiol ; 105(6): 1888-98, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19120637

RESUMEN

AIMS: To isolate and characterize an antifungal protein from the culture broth of the bacterium Bacillus amyloliquefaciens. METHODS AND RESULTS: The antifungal protein designated as baciamin was isolated and exhibited a molecular mass around 50 kDa. Baciamin manifested a broad spectrum of antifungal activity. Baciamin could induce membrane permeabilization of tested fungi. Its antifungal activity was retained after incubation with trypsin and EDTA. Various ions tested did not affect its antifungal activity. Baciamin reduced the activity of HIV-1 reverse transcriptase (RT). It also inhibited proliferation of hepatoma, breast cancer and colon cancer cell lines. Baciamin augmented nitric oxide production by mouse macrophages. CONCLUSIONS: Bacillus amyloliquefaciens produces a broad-spectrum antifungal protein, baciamin. It induces membrane permeabilization in fungi but not in rabbit erythrocytes. Its antifungal activity is relatively thermostable, pH- and trypsin-stable. It demonstrates antiproliferative activity towards various tumour cells, nitric oxide-inducing activity towards macrophages, and inhibitory activity towards HIV-1 RT. SIGNIFICANCE AND IMPACT OF THE STUDY: Baciamin represents one of the few bacterial antifungal proteins reported to date. Most of the previously isolated antifungal molecules of bacterial origin are either peptides or ring compounds. Baciamin also exhibits other exploitable activities such as antitumour and immuno-enhancing activities.


Asunto(s)
Antifúngicos/farmacología , Antineoplásicos/farmacología , Bacillus/química , Bacterias/efectos de los fármacos , Péptidos/farmacología , Proteínas de Plantas/farmacología , Animales , Antifúngicos/aislamiento & purificación , Antineoplásicos/aislamiento & purificación , Línea Celular Tumoral/metabolismo , Proliferación Celular/efectos de los fármacos , Ácido Edético , Transcriptasa Inversa del VIH/antagonistas & inhibidores , Transcriptasa Inversa del VIH/metabolismo , Ratones , Pruebas de Sensibilidad Microbiana , Óxido Nítrico/metabolismo , Péptidos/aislamiento & purificación , Proteínas de Plantas/aislamiento & purificación , Tripsina
18.
Australas Phys Eng Sci Med ; 41(2): 475-485, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29756166

RESUMEN

This study investigates the characteristics and application of the optically-stimulated luminescence dosimeter (OSLD) in cobalt-60 high dose rate (HDR) brachytherapy, and compares the results with the dosage produced by the treatment planning system (TPS). The OSLD characteristics comprised linearity, reproducibility, angular dependence, depth dependence, signal depletion, bleaching rate and cumulative dose measurement. A phantom verification exercise was also conducted using the Farmer ionisation chamber and in vivo diodes. The OSLD signal indicated a supralinear response (R2 = 0.9998). It exhibited a depth-independent trend after a steep dose gradient region. The signal depletion per readout was negligible (0.02%), with expected deviation for angular dependence due to off-axis sensitive volume, ranging from 1 to 16%. The residual signal of the OSLDs after 1 day bleached was within 1.5%. The accumulated and bleached OSLD signals had a standard deviation of ± 0.78 and ± 0.18 Gy, respectively. The TPS was found to underestimate the measured doses with deviations of 5% in OSLD, 17% in the Farmer ionisation chamber, and 7 and 8% for bladder and rectal diode probes. Discrepancies can be due to the positional uncertainty in the high-dose gradient. This demonstrates a slight displacement of the organ at risk near the steep dose gradient region will result in a large dose uncertainty. This justifies the importance of in vivo measurements in cobalt-60 HDR brachytherapy.


Asunto(s)
Braquiterapia , Radioisótopos de Cobalto/química , Calibración , Relación Dosis-Respuesta en la Radiación , Dosimetría con Luminiscencia Ópticamente Estimulada , Fantasmas de Imagen , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador
19.
Phys Med ; 42: 39-46, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29173919

RESUMEN

Challenges in treating lung tumours are related to the respiratory-induced tumour motion and the accuracy of dose calculation in charged particle disequilibrium condition. The dosimetric characteristics near the interface of lung and Perspex media in a moving phantom during respiratory-gated and non-gated radiotherapy were investigated using Gafchromic EBT2 and the MOSkin detector. The MOSkin detectors showed good agreement with the EBT2 films during static and gated radiotherapy. In static radiotherapy, the penumbral widths were found to be 3.66mm and 7.22mm in Perspex and lung media, respectively. In non-gated (moving) radiotherapy with 40mm respiratory amplitude, dose smearing effect was observed and the penumbral widths were increased to 28.81mm and 26.40mm, respectively. This has been reduced to 6.85mm and 9.81mm, respectively, in gated radiotherapy with 25% gating window. There were still some dose discrepancies as compared to static radiotherapy due to the residual motion. This should be taken into account in the margin generation for the target tumour.


Asunto(s)
Pulmón/efectos de la radiación , Movimiento (Física) , Dosificación Radioterapéutica , Radioterapia/métodos , Respiración , Humanos , Pulmón/fisiopatología , Neoplasias Pulmonares/fisiopatología , Neoplasias Pulmonares/radioterapia , Modelos Biológicos , Fantasmas de Imagen , Radiometría/instrumentación , Radioterapia/instrumentación
20.
Med J Malaysia ; 61(2): 204-8, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16898312

RESUMEN

Malaysia's mammography QA practice was surveyed based on the Malaysian Ministry of Health and the American College of Radiology (ACR) requirements. Data on mammography unit, processor, image receptor, exposure factors, mean glandular dose (MGD), sensitometry, image quality and viewbox luminance were obtained. Mean developer temperature and cycle time were 34.1 +/- 1.8degreesC and 107.7 +/- 33.2 seconds. Mean base+fog level, speed index and contrast index were 0.20+/-0.01, 1.20+/-0.01 and 1.33+/-0.26 respectively. Eighty-six percent of the fifty centres passed the image quality test while 12.5% complied with ACR recommended viewbox luminance. Average MGD was 1.0+/-0.4 mGy. Malaysia is on the right track for QA but with room for total quality improvement.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Recolección de Datos/métodos , Mamografía/normas , Garantía de la Calidad de Atención de Salud , Radiología/estadística & datos numéricos , Femenino , Humanos , Malasia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA