Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Rev Soc Bras Med Trop ; 47(1): 12-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24603731

RESUMEN

INTRODUCTION: Hepatitis C virus (HCV) infection is diagnosed by the presence of antibodies and is supplemented by confirmatory testing methods, such as recombinant immunoblot assay (RIBA) and HCV-RNA detection. This study aimed to evaluate the efficacy of RIBA testing to diagnose HCV infection in blood donors positive for anti-HCV antibodies. METHODS: A total of 102 subjects positive for anti-HCV determined by enzyme-linked immunosorbent assay (ELISA) at the Hematology and Hemotherapy Foundation of Bahia (HEMOBA) were later assessed with new samples using the Abbott Architect anti-HCV test (Abbott Diagnostics, Wiesbaden, Germany), the RIBA III test (Chiron RIBA HCV 3.0 SIA, Chiron Corp., Emeryville, CA, USA), the polymerase chain reaction (PCR; COBAS® AMPLICOR HCV Roche Diagnostics Corp., Indianapolis, IN, USA) and line probe assay (LiPA - Siemens, Tarrytown, NY, USA) genotyping for HCV diagnosis. RESULTS: Of these new samples, 38.2% (39/102) were positive, 57.8% (59/102) were negative and 3.9% (4/102) were indeterminate for anti-HCV; HCV-RNA was detected in 22.5% (23/102) of the samples. RIBA results were positive in 58.1% (25/43), negative in 9.3% (4/43) and indeterminate in 32.6% (14/43) of the samples. The prevailing genotypes were 1 (78.3%, 18/23), 3 (17.4%, 4/23) and 2 (4.3%, 1/23). All 14 samples with indeterminate RIBA results had undetectable viral loads (detection limit ≤50 IU/mL). Of these samples, 71.4% (10/14) were reevaluated six months later. Eighty percent (8/10) of these samples remained indeterminate by RIBA, and 20% (2/10) were negative. CONCLUSIONS: In this study, individuals with indeterminate RIBA results had no detectable HCV-RNA.


Asunto(s)
Donantes de Sangre , Hepacivirus/genética , Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/diagnóstico , ARN Viral/sangre , Adulto , Ensayo de Inmunoadsorción Enzimática , Femenino , Genotipo , Hepacivirus/inmunología , Humanos , Immunoblotting , Masculino , Reacción en Cadena de la Polimerasa , Proteínas Recombinantes , Carga Viral
2.
Rev. Soc. Bras. Med. Trop ; Rev. Soc. Bras. Med. Trop;47(1): 12-17, Jan-Feb/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-703147

RESUMEN

Introduction: Hepatitis C virus (HCV) infection is diagnosed by the presence of antibodies and is supplemented by confirmatory testing methods, such as recombinant immunoblot assay (RIBA) and HCV-RNA detection. This study aimed to evaluate the efficacy of RIBA testing to diagnose HCV infection in blood donors positive for anti-HCV antibodies. Methods: A total of 102 subjects positive for anti-HCV determined by enzyme-linked immunosorbent assay (ELISA) at the Hematology and Hemotherapy Foundation of Bahia (HEMOBA) were later assessed with new samples using the Abbott Architect anti-HCV test (Abbott Diagnostics, Wiesbaden, Germany), the RIBA III test (Chiron RIBA HCV 3.0 SIA, Chiron Corp., Emeryville, CA, USA), the polymerase chain reaction (PCR; COBAS® AMPLICOR HCV Roche Diagnostics Corp., Indianapolis, IN, USA) and line probe assay (LiPA - Siemens, Tarrytown, NY, USA) genotyping for HCV diagnosis. Results: Of these new samples, 38.2% (39/102) were positive, 57.8% (59/102) were negative and 3.9% (4/102) were indeterminate for anti-HCV; HCV-RNA was detected in 22.5% (23/102) of the samples. RIBA results were positive in 58.1% (25/43), negative in 9.3% (4/43) and indeterminate in 32.6% (14/43) of the samples. The prevailing genotypes were 1 (78.3%, 18/23), 3 (17.4%, 4/23) and 2 (4.3%, 1/23). All 14 samples with indeterminate RIBA results had undetectable viral loads (detection limit ≤50 IU/mL). Of these samples, 71.4% (10/14) were reevaluated six months later. Eighty percent (8/10) of these samples remained indeterminate by RIBA, and 20% (2/10) were negative. Conclusions: In this study, individuals with indeterminate RIBA results had no detectable HCV-RNA. .


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Donantes de Sangre , Hepacivirus/genética , Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/diagnóstico , ARN Viral/sangre , Ensayo de Inmunoadsorción Enzimática , Genotipo , Hepacivirus/inmunología , Immunoblotting , Reacción en Cadena de la Polimerasa , Proteínas Recombinantes , Carga Viral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA