Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 520
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Transl Med ; 22(1): 405, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689321

RESUMEN

BACKGROUND: Retinal detachment (RD) is a vision-threatening disorder of significant severity. Individuals with high myopia (HM) face a 2 to 6 times higher risk of developing RD compared to non-myopes. The timely identification of high myopia-related retinal detachment (HMRD) is crucial for effective treatment and prevention of additional vision impairment. Consequently, our objective was to streamline and validate a machine-learning model based on clinical laboratory omics (clinlabomics) for the early detection of RD in HM patients. METHODS: We extracted clinlabomics data from the electronic health records for 24,440 HM and 5607 HMRD between 2015 and 2022. Lasso regression analysis assessed fifty-nine variables, excluding collinear variables (variance inflation factor > 10). Four models based on random forest, gradient boosting machine (GBM), generalized linear model, and Deep Learning Model were trained for HMRD diagnosis and employed for internal validation. An external test of the models was done. Three random data sets were further processed to validate the performance of the diagnostic model. The primary outcomes were the area under the receiver operating characteristic curve (AUC) and the area under the precision-recall curve (AUCPR) to diagnose HMRD. RESULTS: Nine variables were selected by all models. Given the AUC and AUCPR values across the different sets, the GBM model was chosen as the final diagnostic model. The GBM model had an AUC of 0.8550 (95%CI = 0.8322-0.8967) and an AUCPR of 0.5584 (95%CI = 0.5250-0.5879) in the training set. The AUC and AUCPR in the internal validation were 0.8405 (95%CI = 0.8060-0.8966) and 0.5355 (95%CI = 0.4988-0.5732). During the external test evaluation, it reached an AUC of 0.7579 (95%CI = 0.7340-0.7840) and an AUCPR of 0.5587 (95%CI = 0.5345-0.5880). A similar discriminative capacity was observed in the three random data sets. The GBM model was well-calibrated across all the sets. The GBM-RD model was implemented into a web application that provides risk prediction for HM individuals. CONCLUSION: GBM algorithms based on nine features successfully predicted the diagnosis of RD in patients with HM, which will help ophthalmologists to establish a preliminary diagnosis and to improve diagnostic accuracy in the clinic.


Asunto(s)
Diagnóstico Precoz , Aprendizaje Automático , Miopía , Curva ROC , Desprendimiento de Retina , Humanos , Miopía/diagnóstico , Miopía/complicaciones , Desprendimiento de Retina/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto , Área Bajo la Curva
2.
J Transl Med ; 22(1): 289, 2024 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-38494492

RESUMEN

BACKGROUND: Global myopia prevalence poses a substantial public health burden with vision-threatening complications, necessitating effective prevention and control strategies. Precise prediction of spherical equivalent (SE), myopia, and high myopia onset is vital for proactive clinical interventions. METHODS: We reviewed electronic medical records of pediatric and adolescent patients who underwent cycloplegic refraction measurements at the Eye & Ear, Nose, and Throat Hospital of Fudan University between January 2005 and December 2019. Patients aged 3-18 years who met the inclusion criteria were enrolled in this study. To predict the SE and onset of myopia and high myopia in a specific year, two distinct models, random forest (RF) and the gradient boosted tree algorithm (XGBoost), were trained and validated based on variables such as age at baseline, and SE at various intervals. Outputs included SE, the onset of myopia, and high myopia up to 15 years post-initial examination. Age-stratified analyses and feature importance assessments were conducted to augment the clinical significance of the models. RESULTS: The study enrolled 88,250 individuals with 408,255 refraction records. The XGBoost-based SE prediction model consistently demonstrated robust and better performance than RF over 15 years, maintaining an R2 exceeding 0.729, and a Mean Absolute Error ranging from 0.078 to 1.802 in the test set. Myopia onset prediction exhibited strong area under the curve (AUC) values between 0.845 and 0.953 over 15 years, and high myopia onset prediction showed robust AUC values (0.807-0.997 over 13 years, with the 14th year at 0.765), emphasizing the models' effectiveness across age groups and temporal dimensions on the test set. Additionally, our classification models exhibited excellent calibration, as evidenced by consistently low brier score values, all falling below 0.25. Moreover, our findings underscore the importance of commencing regular examinations at an early age to predict high myopia. CONCLUSIONS: The XGBoost predictive models exhibited high accuracy in predicting SE, onset of myopia, and high myopia among children and adolescents aged 3-18 years. Our findings emphasize the importance of early and regular examinations at a young age for predicting high myopia, thereby providing valuable insights for clinical practice.


Asunto(s)
Miopía , Refracción Ocular , Adolescente , Niño , Preescolar , Humanos , Miopía/diagnóstico , Miopía/epidemiología
3.
Exp Eye Res ; 244: 109930, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38750782

RESUMEN

Corneal neovascularization (CoNV) is a vision-threatening ocular disease commonly secondary to infectious, inflammatory, and traumatic etiologies. Slit lamp photography, in vivo confocal microscopy, angiography, and optical coherence tomography angiography (OCTA) are the primary diagnostic tools utilized in clinical practice to evaluate the vasculature of the ocular surface. However, there is currently a dearth of comprehensive literature that reviews the advancements in imaging technology for CoNV administration. Initially designed for retinal vascular imaging, OCTA has now been expanded to the anterior segment and has shown promising potential for imaging the conjunctiva, cornea, and iris. This expansion allows for the quantitative monitoring of the structural and functional changes associated with CoNV. In this review, we emphasize the impact of algorithm optimization in anterior segment-optical coherence tomography angiography (AS-OCTA) on the diagnostic efficacy of CoNV. Through the analysis of existing literature, animal model assessments are further reported to investigate its pathological mechanism and exhibit remarkable therapeutic interventions. In conclusion, AS-OCTA holds broad prospects and extensive potential for clinical diagnostics and research applications in CoNV.


Asunto(s)
Neovascularización de la Córnea , Angiografía con Fluoresceína , Tomografía de Coherencia Óptica , Neovascularización de la Córnea/diagnóstico , Humanos , Tomografía de Coherencia Óptica/métodos , Animales , Angiografía con Fluoresceína/métodos , Córnea/irrigación sanguínea , Córnea/patología , Córnea/diagnóstico por imagen , Microscopía Confocal
4.
Exp Eye Res ; 238: 109726, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37979904

RESUMEN

This study aimed to investigate the underlying pathophysiology of high myopia by analyzing the proteome of human corneal stromal lenticule samples obtained through small incision lenticule extraction (SMILE). A total of thirty-two patients who underwent SMILE were included in the study. Label-free quantitative proteomic analysis was performed on corneal stromal lenticule samples, equally representing high myopia (n = 10) and low myopia (n = 10) groups. The identified and profiled lenticule proteomes were analyzed using in silico tools to explore biological characteristics of differentially expressed proteins (DEPs). Additionally, LASSO regression and random forest model were employed to identify key proteins associated with the pathophysiology of high myopia. The DEPs were found to be closely linked to immune activation, extracellular matrix, and cell adhesion-related pathways according to gene ontology analysis. Specifically, decreased expression of COL1A1 and increased expression of CDH11 were associated with the pathogenesis of high myopia and validated by western blotting (n = 6) and quantitative real time polymerase chain reaction (n = 6). Overall, this study provides evidence that COL1A1 and CDH11 may contribute to the pathophysiology of high myopia based on comparative proteomic profiling of human corneal stromal lenticules obtained through SMILE.


Asunto(s)
Cirugía Laser de Córnea , Miopía , Humanos , Proteómica , Sustancia Propia/metabolismo , Miopía/metabolismo , Láseres de Excímeros
5.
Exp Eye Res ; 239: 109786, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38211681

RESUMEN

To investigate regional changes in the chick retina and choroid after hemifield form deprivation (HFD). Ten chicks were randomly and equally divided into a temporal retinal deprivation (TRD) and nasal retinal deprivation (NRD) group. HFD was induced with half-lateral translucent plastic goggles in the right eye; the left eye was kept untreated. Swept-source optical coherence tomography (SS-OCT) images obtained at 0, 3, and 72 hours (h) were analyzed using customized software. After 72 h of TRD, the retinal thickness (RT) of the treated eyes was significantly less than that of the fellow eyes in the temporal (P = 0.034) rather than the nasal (P = 0.083) region. In the NRD group, the RT of the treated eyes was thinner in both the nasal and temporal regions than that of the fellow eyes (P < 0.01). The RT alterations were more pronounced in the temporal (Δ = -16.86 ± 7.14 µm) than in the nasal (Δ = -13.44 ± 4.83 µm) region after 72-h TRD (P = 0.036), whereas the opposite was observed in the NRD group (P = 0.008). The choroidal thickness (ChT) of the treated eyes was less in both the nasal and temporal regions than that of the fellow eyes in both groups after 72-h treatment (P < 0.01). The ChT alterations were more pronounced in the temporal (Δ = -2.48 ± 8.95 µm) than in the nasal (Δ = 23.65 ± 13.58 µm) region after 72-h TRD (P = 0.021), whereas the NRD group showed the opposite effect (P = 0.019). HFD in chicks can lead to retinal and choroidal thinning in the corresponding regions.


Asunto(s)
Coroides , Retina , Animales , Pollos , Tomografía de Coherencia Óptica/métodos
6.
Exp Eye Res ; 239: 109756, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38135134

RESUMEN

PURPOSE: To investigate the long-term preservation effects of nutrient capsules on the physiological activity, collagen fiber structure and transmittance of corneal stromal lenticules derived from small incision lenticule extraction (SMILE). METHODS: A new nutrient capsule was constructed for long-term preservation of SMILE-derived corneal stromal lenticules. The lenticules were randomly divided into 99% anhydrous glycerol, and hydrogel nutrient capsules. After preserving for 1 year at -80 °C, lenticules were compared with fresh lenticules. The optical transmittance, tissue morphology, ultrastructure, cells activity and immunogenicity of the lenticules was detected and compared between different groups. RESULTS: The rate of apoptotic cells was significantly higher in the glycerol group compared with the nutrient capsule group (P < 0.0001). More viable cells were present in the lenticules after nutrient capsule preservation compared to the glycerol group (P = 0.0003). The mean transmittance of the lenticules in the glycerol group (50 ± 18%) was significantly lower (P = 0.0008) compared to the control group (75 ± 11%), and the lenticules transmittance of the nutrient capsule group (64 ± 15%) after long-term preservation was not significantly different (P = 0.23) compared to the control group. The structure of HE staining showed that the collagen fibers in the nutrient capsule group were arranged in parallel and neatly, and a few cavitation vesicles were visible inside the tissue. There was no significant difference in the number of lenticular collagen fibers in the nutritional capsule group compared to the fresh lenticule group (P = 0.06). HLA-DR, HLA-ABC, CD45, CD25 and CD69 expression was low in all groups of lenticules after preservation. CONCLUSIONS: Nutrient capsules can preserve lenticules for a long time and maintain the transmission structure and cells activity of lenticules.


Asunto(s)
Sustancia Propia , Glicerol , Glicerol/farmacología , Criopreservación , Colágeno/farmacología , Matriz Extracelular
7.
BMC Med Res Methodol ; 24(1): 194, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39243025

RESUMEN

BACKGROUND: Early identification of children at high risk of developing myopia is essential to prevent myopia progression by introducing timely interventions. However, missing data and measurement error (ME) are common challenges in risk prediction modelling that can introduce bias in myopia prediction. METHODS: We explore four imputation methods to address missing data and ME: single imputation (SI), multiple imputation under missing at random (MI-MAR), multiple imputation with calibration procedure (MI-ME), and multiple imputation under missing not at random (MI-MNAR). We compare four machine-learning models (Decision Tree, Naive Bayes, Random Forest, and Xgboost) and three statistical models (logistic regression, stepwise logistic regression, and least absolute shrinkage and selection operator logistic regression) in myopia risk prediction. We apply these models to the Shanghai Jinshan Myopia Cohort Study and also conduct a simulation study to investigate the impact of missing mechanisms, the degree of ME, and the importance of predictors on model performance. Model performance is evaluated using the receiver operating characteristic curve (AUROC) and the area under the precision-recall curve (AUPRC). RESULTS: Our findings indicate that in scenarios with missing data and ME, using MI-ME in combination with logistic regression yields the best prediction results. In scenarios without ME, employing MI-MAR to handle missing data outperforms SI regardless of the missing mechanisms. When ME has a greater impact on prediction than missing data, the relative advantage of MI-MAR diminishes, and MI-ME becomes more superior. Furthermore, our results demonstrate that statistical models exhibit better prediction performance than machine-learning models. CONCLUSION: MI-ME emerges as a reliable method for handling missing data and ME in important predictors for early-onset myopia risk prediction.


Asunto(s)
Aprendizaje Automático , Miopía , Humanos , Miopía/diagnóstico , Miopía/epidemiología , Femenino , Niño , Masculino , Modelos Logísticos , Modelos Estadísticos , Medición de Riesgo/métodos , Medición de Riesgo/estadística & datos numéricos , Factores de Riesgo , Curva ROC , Teorema de Bayes , China/epidemiología , Estudios de Cohortes , Edad de Inicio
8.
J Nanobiotechnology ; 22(1): 588, 2024 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-39342257

RESUMEN

Riboflavin-5-phosphate (riboflavin) is the most commonly used photosensitizer in corneal crosslinking (CXL); while its efficient delivery into the stroma through the corneal epithelial barrier is challenging. In this paper, we presented novel responsive porous microneedles with ocular microinjection capability to deliver riboflavin controllably inside the cornea to facilitate CXL. The microneedle patch was composed of Poly (N-isopropyl acrylamide) (PNIPAM), graphene oxide (GO), and riboflavin-loaded gelatin. After penetrating the cornea by the stiff and porous gelatin needle tip, the photothermal-responsive characteristic of the PNIPAM/GO hydrogel middle layer could realize the contraction of the gel under the stimulation of near-infrared light, which subsequently could control the release of riboflavin from the backing layer into the cornea stromal site both in vitro and in vivo. Based on the microneedles system, we have demonstrated that this microinjection technique exhibited superior riboflavin delivery capacity and treatment efficacy to the conventional epithelial-on protocol in a rabbit keratoconus model, with benefits including minimal invasiveness and precise administering. Thus, we believe the responsive porous microneedles with riboflavin ocular microinjection capability are promising for clinical corneal crosslinking without epithelial debridement.


Asunto(s)
Córnea , Reactivos de Enlaces Cruzados , Microinyecciones , Agujas , Fármacos Fotosensibilizantes , Riboflavina , Riboflavina/farmacología , Animales , Microinyecciones/métodos , Microinyecciones/instrumentación , Conejos , Córnea/efectos de los fármacos , Porosidad , Reactivos de Enlaces Cruzados/química , Fármacos Fotosensibilizantes/farmacología , Queratocono/tratamiento farmacológico , Grafito/química , Resinas Acrílicas/química , Sistemas de Liberación de Medicamentos/métodos , Hidrogeles/química , Gelatina/química , Modelos Animales de Enfermedad
9.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 313-321, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37405512

RESUMEN

PURPOSE: To investigate changes in disk halo size after small incision lenticule extraction (SMILE) and the correlation between halo size and lenticule quality in moderate to high myopia. METHODS: Thirty eyes of 30 consecutive patients (mean age, 24.9 ± 4.5 years; mean spherical equivalent, -6.85 ± 1.18 D) undergoing SMILE were included in this prospective study. Lenticule surface quality was accessed with a scanning electron microscopy by a scoring system. Halo size was measured preoperatively and at 1, 3, and 6 months postoperatively. Multiple linear regression analysis was performed to explore associations between halo size and a range of factors, including lenticule quality. RESULTS: Disk halo size increased slightly at 1 month and then recovered continually from 3 to 6 months postoperatively, with no difference between halo size during the preoperative period and at 6 months postoperatively (P > 0.05). One month after SMILE, halo size (1 cd/m2, 5 cd/m2) was associated only with uncorrected distance visual acuity (P ≤ 0.004). A halo size of 5 cd/m2 at 3 months postoperatively correlated with the anterior surface quality of the lenticule (P = 0.046). At 6 months postoperatively, a halo size of 1 cd/m2 was associated only with the baseline, accounting for 11.9% of the variability (P = 0.041); no correlations were found for the halo size of 5 cd/m2. CONCLUSIONS: Disk halo size after SMILE was enlarged at an early stage postoperatively and subsequently declined to the baseline level during a 6-month follow-up. The quality of the lenticule surface influenced halo size changes in the early phase.


Asunto(s)
Cirugía Laser de Córnea , Miopía , Humanos , Adulto Joven , Adulto , Sustancia Propia/cirugía , Estudios Prospectivos , Miopía/diagnóstico , Miopía/cirugía , Agudeza Visual , Refracción Ocular , Láseres de Excímeros/uso terapéutico , Resultado del Tratamiento
10.
Artículo en Inglés | MEDLINE | ID: mdl-38916723

RESUMEN

BACKGROUND: The purpose of this study was to identify the possible association between mental status and the risk of self-reported asthenopia among college students in China. METHODS: Ten thousand students were randomly assessed in the study using a self-reported asthenopia questionnaire. Their demographic characteristics and mental status were recorded. Univariate analysis was performed to preliminarily select potential risk and protective factors. Then, multivariate logistic regression was used to estimate odds ratios for the selected risk factors of interest. RESULTS: Among the 8370 students who completed the survey, the prevalence of asthenopia was 61.0%. Multivariate analysis revealed a significant relationship between asthenopia and depressive symptoms (OR 1.511 95% CI: 1.350-1.691), obsessive-compulsive symptoms (OR 1.477, 95% CI: 1.338-1.632), gender and study load. The place college students spent their off-hours (OR 0.841, 95% CI: 0.784-0.902) was found to be the strongest factor for decreasing the occurrence of asthenopia complaints. CONCLUSION: Asthenopia appears common in Chinese college students. In addition to depressive symptoms, we should pay attention to obsessive-compulsive symptoms when considering means of preventing asthenopia. Harmonious social relationships, outdoor off-hour activities and exercising more than three times per week are crucial to relieving visual fatigue. Further study is still needed in this area.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38753024

RESUMEN

To evaluate lenticular biomechanical and geometric parameters in Chinese adults with myopia and identify relevant factors using Brillouin microscopy (BM) and Pentacam. The biomechanical and geometric properties of the ocular lenses of Chinese adults with myopia were quantified using BM. Anterior segment images were acquired using a Pentacam. Correlated factors including age, sex, spherical equivalent (SE), intraocular pressure (IOP), axial length (AL), white-to-white ratio (WTW), central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were analyzed. We studied 65 eyes from 65 participants (mean age, 25.23 ± 6.12 years). Width of Top Plateau (WTP), Width of Bottom Plateau (WBP), Slope of Anterior Cortex (SAC), Slope of Posterior Cortex (SPC), and Height of Plateau (Height) metrics obtained using BM showed mean values of 2.597 ± 0.393 mm, 4.310 ± 0.535 mm, 1.344 ± 0.549 GPa/mm, -1.343 ± 0.480 GPa/mm, and 3.373 ± 0.048 GPa, respectively. No significant correlation was found between these parameters and sex, SE, IOP, CCT, ACA, or Height. Interestingly, WBP (r = 0.467, P < 0.001), SAC (r = 0.412, P = 0.001), and SPC (r = -0.280, P = 0.024) were significantly associated with age, and an age-related increase of WBP (slope of 35.36 ± 10.08 µm per year) was identified. Both ACD and ACV showed significant correlations with SAC (r = 0.329 and 0.380, P = 0.008 and 0.002, respectively), but not with SPC. BM provided a novel perspective on lenticular biomechanical and geometric properties in Chinese adults with myopia, which correlated with age, AL, WTW, ACD, and ACV.

12.
Retina ; 44(3): 527-536, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37972986

RESUMEN

PURPOSE: To investigate fundus tessellation density (TD) and its association with axial length (AL) elongation and spherical equivalent (SE) progression in children. METHODS: The school-based prospective cohort study enrolled 1,997 individuals aged 7 to 9 years in 11 elementary schools in Mojiang, China. Cycloplegic refraction and biometry were performed at baseline and 4-year visits. The baseline fundus photographs were taken, and TD, defined as the percentage of exposed choroidal vessel area in the photographs, was quantified using an artificial intelligence-assisted semiautomatic labeling approach. After the exclusion of 330 ineligible participants because of loss to follow-up or ineligible fundus photographs, logistic models were used to assess the association of TD with rapid AL elongation (>0.36 mm/year) and SE progression (>1.00 D/year). RESULTS: The prevalence of tessellation was 477 of 1,667 (28.6%) and mean TD was 0.008 ± 0.019. The mean AL elongation and SE progression in 4 years were 0.90 ± 0.58 mm and -1.09 ± 1.25 D. Higher TD was associated with longer baseline AL (ß, 0.030; 95% confidence interval: 0.015-0.046; P < 0.001) and more myopic baseline SE (ß, -0.017; 95% confidence interval: -0.032 to -0.002; P = 0.029). Higher TD was associated with rapid AL elongation (odds ratio, 1.128; 95% confidence interval: 1.055-1.207; P < 0.001) and SE progression (odds ratio, 1.123; 95% confidence interval: 1.020-1.237; P = 0.018). CONCLUSION: Tessellation density is a potential indicator of rapid AL elongation and refractive progression in children. TD measurement could be a routine to monitor AL elongation.


Asunto(s)
Inteligencia Artificial , Miopía , Niño , Humanos , Estudios Prospectivos , Refracción Ocular , Pruebas de Visión , Miopía/diagnóstico , Miopía/epidemiología , Longitud Axial del Ojo
13.
BMC Ophthalmol ; 24(1): 408, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39300374

RESUMEN

BACKGROUND: Implantable Collamer Lense (ICL) presents a viable alternative to conventional refractive surgeries, but their impact on corneal microstructure remains unclear. By employing in vivo confocal microscopy (IVCM), we examined changes in stromal and endothelial cells following the insertion of V4c ICLs, with the goal of enhancing post-surgical care and outcomes. METHODS: In this longitudinal investigation, we conducted detailed preoperative assessments on 103 eyes from 53 participants. Follow-up evaluations were carried out after surgery at set intervals: one day, one week, one month, three months, six months, and twelve months. We used IVCM to analyze changes in stromal and endothelial cells. To assess differences between pre- and post-surgery variables and to investigate correlations with age, axial length (AL), and spherical equivalent refraction (SER), we applied a repeated measures mixed-effects model, with statistical significance set at P < 0.05. RESULTS: No vision-threatening complications were reported post-surgery. Significant reductions in stromal cell density (SCD) were observed postoperatively, with anterior and mid- SCD reaching their lowest values at 3 months and posterior SCD at 1 month, remaining below baseline at 12 months. endothelial cell density (ECD) and percentage of hexagonal cells (PHC) decreased initially, recovering by 12 months. Conversely, endothelial cellular area (ECA) and coefficient of variation of cell size (CoV) increased postoperatively, with the most significant change at 1 week. Endothelial deposits were detected in 49 of 101 eyes on postoperative day 1, half of them were absorbed within 3 months post-surgery. Changes in posterior SCD were negatively related to AL, while AL, SER, lens thickness showed associated with endothelium changes. CONCLUSION: Our findings elucidate the corneal microstructural changes following V4c ICL implantation, particularly the significant early reductions in stromal and endothelial cell densities. We recommend careful management of viscoelastics during surgery to minimize endothelial deposits that may harm the endothelium. Enhanced early postoperative monitoring and these surgical adjustments can lead to improved surgical and post-surgical care, ultimately supporting better patient recovery.


Asunto(s)
Endotelio Corneal , Microscopía Confocal , Miopía , Lentes Intraoculares Fáquicas , Humanos , Masculino , Femenino , Adulto , Endotelio Corneal/patología , Miopía/cirugía , Recuento de Células , Implantación de Lentes Intraoculares , Adulto Joven , Persona de Mediana Edad , Sustancia Propia/patología , Sustancia Propia/cirugía , Sustancia Propia/diagnóstico por imagen , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Estudios de Seguimiento , Estudios Prospectivos
14.
BMC Ophthalmol ; 24(1): 110, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454381

RESUMEN

BACKGROUND: To investigate the change in the distance between corneal apex and pupil center after small-incision lenticule extraction (SMILE) or implantable collamer lens (ICL) implantation and its correlation with surgical-induced astigmatism (SIA). METHODS: This study included patients who had undergone SMILE (n = 112) or ICL implantation (n = 110) to correct myopia and myopic astigmatism. The angle kappa was measured using a Scheimpflug imaging device (Pentacam) and represented as Cartesian values between the pupil center and the corneal vertex (X, Y) and chord u ([Formula: see text]orientation), and was compared pre- and post-operative. RESULTS: Following SMILE, the magnitude of chord u[Formula: see text]) significantly increased in both eyes (Wilcoxon signed-rank test, OD: P<0.001; OS: P=0.007), while no significant change was observed in the orientation. A significant correlation was found between the J0 component of SIA and the change in the magnitude of chord u for both eyes (OD: R2=0.128, P<0.001; OS: R2=0.033, P=0.004). After ICL implantation, the orientation of the chord u was significantly different in the right eye (Wilcoxon signed-rank test, P = 0.008), and the Y-intercept significantly decreased in both eyes (Wilcoxon signed-rank test, P<0.001). A significant correlation was found between J0 of SIA and the change in the magnitude of chord u for the right eyes (R2=0.066, P=0.002). A significant correlation was found between J45 of SIA and the change in the magnitude of chord u for the left eyes (R2=0.037, P=0.044). CONCLUSIONS: The magnitude of the chord u increased following the SMILE procedure, whereas the Y-intercept significantly decreased after ICL implantation. SIA was related to the change in the magnitude of chord u.


Asunto(s)
Astigmatismo , Humanos , Astigmatismo/diagnóstico , Astigmatismo/etiología , Astigmatismo/cirugía , Refracción Ocular , Agudeza Visual , Pupila , Topografía de la Córnea
15.
BMC Ophthalmol ; 24(1): 289, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014346

RESUMEN

BACKGROUND: This study assessed the agreement of ocular parameters of patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700. METHODS: Eighty patients (male, 22; average age, 29.14 ± 7.36 years) with myopia (159 eyes) were included in this study in May 2023. The participants' axial length (AXL), central corneal thickness (CCT), lens thickness (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) corneal keratometry, astigmatism (Astig), J0 vector, and J45 vector were measured using the IOLMaster 700 and Colombo IOL 2. The measurements from both devices were compared using the generalized estimating equation, correlation analysis, and Bland-Altman plots. RESULTS: With the Colombo IOL 2, lower values for K2 and J0 (odds ratio [OR] = 0.587, p = 0.033; OR = 0.779, p < 0.0001, respectively), and larger values for WTW, Astig, and J45 (OR = 1.277, OR = 1.482, OR = 1.1, all p < 0.0001) were obtained. All ocular measurements by both instruments showed positive correlations, with AXL demonstrating the strongest correlation (r = 0.9996, p < 0.0001). The intraclass correlation coefficients for AXL and CCT measured by both instruments was 0.999 and 0.988 (both p < 0.0001), and Bland-Altman plot showed 95% limits of agreement (LoA) of -0.078 to 0.11 mm and - 9.989 to 13.486 µm, respectively. The maximum absolute 95% LoA for LT, WTW, K1, K2, and J0 were relatively high, achieving 0.829 mm, 0.717 mm, 0.983 D, 0.948 D, and 0.632 D, respectively. CONCLUSIONS: In young patients with myopia, CCT and AXL measurements obtained with the Colombo IOL 2 and IOLMaster 700 were comparable. However, WTW, LT, corneal refractive power, and astigmatism values could not be used interchangeably in clinical practice.


Asunto(s)
Longitud Axial del Ojo , Biometría , Miopía , Humanos , Masculino , Biometría/métodos , Biometría/instrumentación , Longitud Axial del Ojo/patología , Miopía/fisiopatología , Miopía/diagnóstico , Femenino , Adulto , Adulto Joven , Análisis de Fourier , Tomografía de Coherencia Óptica/métodos , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/patología , Córnea/patología , Córnea/diagnóstico por imagen , Refracción Ocular/fisiología
16.
BMC Ophthalmol ; 24(1): 388, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227793

RESUMEN

BACKGROUND: Visual quality after corneal refractive surgery is linked to the postoperative effective optical zone (EOZ). This study aims to compare long-term changes in the EOZ following small incision lenticule extraction (SMILE) and femtosecond laser-assisted in-situ keratomileusis (FS-LASIK) for moderate and high myopia. METHODS: This study included 42 patients (72 eyes) who underwent either SMILE (36 eyes) or FS-LASIK (36 eyes). A custom software program based on the tangential curvature difference map of the Pentacam HR (Oculus Optikgeräte GmbH) was used to define the EOZ at 3 and 7 years postoperatively. The EOZ, its chronological changes compared to the programmed optical zone (POZ), and the corneal wavefront aberrations following SMILE and FS-LASIK were analyzed. Correlations between the EOZ changes and relevant parameters were evaluated. RESULTS: Three years postoperatively, EOZ following SMILE and FS-LASIK were 5.13 ± 0.27 mm and 4.70 ± 0.24 mm (P < 0.001), respectively. Seven years postoperatively, EOZ following SMILE and FS-LASIK decreased to 5.03 ± 0.28 mm and 4.63 ± 0.23 mm (P < 0.001), respectively. At postoperative 7 years, the percentages of EOZ/POZ were negatively correlated with Q-value changes (ß = -5.120, P = 0.009) following SMILE and positively correlated with the cylinder correction (ß = 1.184, P = 0.004) following FS-LASIK. The induced spherical aberrations in the SMILE group were less than those in the FS-LASIK group (P < 0.05) and were negatively correlated with the EOZ/POZ (ß = -16.653, P < 0.001). CONCLUSIONS: The EOZ following SMILE was larger than that following FS-LASIK in the long postoperative term for moderate and high myopia. Furthermore, a continual reduction in the EOZ was noted after both surgical modalities.


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Femenino , Adulto , Masculino , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Láseres de Excímeros/uso terapéutico , Adulto Joven , Estudios de Seguimiento , Estudios Retrospectivos , Miopía/cirugía , Miopía/fisiopatología , Sustancia Propia/cirugía , Cirugía Laser de Córnea/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Córnea/cirugía , Miopía Degenerativa/cirugía , Miopía Degenerativa/fisiopatología , Periodo Posoperatorio
17.
BMC Ophthalmol ; 24(1): 143, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38549060

RESUMEN

AIM: To investigate the correlation of angles α and κ with the refractive and biological parameters in children. METHODS: This case-series study included 438 eyes of 219 children (males/females = 105/114, age: 3-15 years). Ocular biometric parameters, including axial length, corneal radius of curvature (CR), white-to-white distance (WTW), angle κ and angle α, were measured using IOL Master 700; auto-refraction were assessed under cycloplegia. The eyes were assigned to different groups based on CR, WTW, and gender to compare the angles α and κ, and analyze the correlations between the differences of biological parameters on angles α and κ. RESULTS: The means of axial length, CR, WTW, angle α, and angle κ were 23.24 ± 1.14 mm, 7.79 ± 0.27 mm, 11.68 ± 0.41 mm, 0.45 ± 0.25 mm, and 0.27 ± 0.22 mm, respectively. Angle α was correlated with CR and WTW (fixed effect coefficient [FEC] = 0.237, p = 0.015; FEC = -0.109, p = 0.003; respectively), and angle κ also correlated with CR and WTW (FEC = 0.271, p = 0.003; FEC = -0.147, p < 0.001, respectively). Comparing subgroups, the large CR and small WTW group had larger angles α (0.49 ± 0.27 vs. 0.41 ± 0.21, p < 0.001; 0.46 ± 0.27 vs. 0.44 ± 0.21, p < 0.05, respectively) and κ (0.29 ± 0.25 vs. 0.24 ± 0.15, p < 0.01; 0.29 ± 0.25 vs. 0.26 ± 0.19, p < 0.05, respectively). The differences in interocular angles α and κ showed correlation with interocular WTW (r = - 0.255, p < 0.001; r = - 0.385, p < 0.001). Eyes with smaller WTW tended to have larger angle κ (0.28 ± 0.27 vs. 0.25 ± 0.15, p < 0.05). CONCLUSION: The size of angle α/κ may be correlated to CR and WTW, and a larger WTW eye may suggest a smaller angle κ compared with the fellow eye.


Asunto(s)
Presbiopía , Refracción Ocular , Niño , Humanos , Femenino , Masculino , Preescolar , Adolescente , Pruebas de Visión , Córnea , Biometría , Longitud Axial del Ojo
18.
Ophthalmic Physiol Opt ; 44(6): 1309-1318, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38980219

RESUMEN

PURPOSE: Autostereoscopic displays have become increasingly common, but their impact on ocular dimensions remains unknown. We sought to identify changes in the crystalline lens dimensions induced by autostereoscopic three-dimensional (3D) viewing. METHODS: Forty young adults (age: 22.6 ± 2.0 years, male/female: 15/25) were consecutively enrolled and randomly divided into two groups (3D and two-dimensional [2D] viewing groups) to watch a 30-min movie clip displayed in 3D or 2D mode on a tablet computer. The lens thickness (LT), diameter, curvature, decentration and tilt were measured with anterior segment optical coherence tomography under both non-accommodating (static) and accommodating conditions. RESULTS: In the static condition, the LT decreased by 0.03 ± 0.03 mm (p < 0.001) and the anterior radius of curvature (ARC) increased by 0.49 ± 0.59 mm (p = 0.001) post-3D viewing. In contrast, following 2D viewing, the ARC decreased by 0.23 ± 0.25 mm (p = 0.001). Additionally, the increase in the steep ARC post-3D viewing was greater in high-myopic eyes than low to moderate myopic eyes (p = 0.04). When comparing the accommodative with the static (non-accommodative) condition, for 3D viewing the lens decentration decreased (-0.03 ± 0.05 mm, p = 0.02); while for 2D viewing, the posterior curvature radius (-0.14 ± 0.20 mm, p = 0.006) and diameter (-0.13 ± 0.20 mm, p = 0.01) decreased. CONCLUSIONS: Viewing with the autostereoscopic 3D tablet could temporally decrease the thickness and curvature of the lens under non-accommodating conditions. However, its long-term effect requires further exploration.


Asunto(s)
Acomodación Ocular , Imagenología Tridimensional , Cristalino , Miopía , Tomografía de Coherencia Óptica , Humanos , Femenino , Masculino , Adulto Joven , Tomografía de Coherencia Óptica/métodos , Imagenología Tridimensional/métodos , Cristalino/diagnóstico por imagen , Acomodación Ocular/fisiología , Miopía/fisiopatología , Miopía/diagnóstico , Refracción Ocular/fisiología , Adulto
19.
Clin Exp Ophthalmol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39119923

RESUMEN

BACKGROUND: To establish a novel vault prediction formula after implantable collamer lens (ICL) implantation that considers both anterior and posterior chamber characteristics with multi-modal parameters. METHODS: A total of 103 and 65 eyes were included in the development and validation groups, respectively. Exploratory factor analysis was performed using data from optical coherence tomography and ultrasound biomicroscopy in the development group to synthesise summative factors with different clinical significance. Dominant original metrics with heavy loadings on significant factors (absolute value of the loading coefficient >0.5) were screened for multivariate linear regression models using a stepwise method. The newly derived formula was evaluated and compared to the NK and KS formulas in the validation group. RESULTS: Six factors (anterior chamber angle, horizontal width, lens, iris, iridociliary complex and ciliary body) were generated after dimension reduction via factor analysis. Factors 2 (horizontal width), 3 (lens), and 5 (iridociliary complex) had a significant influence on the vault. When dominant metrics on these factors were screened for further model building, ICL size, anterior chamber width, crystalline lens rise, iris curvature, and iris-ciliary process distance were retained in the final formula, with an adjusted R2 of 0.698, a median absolute error of 81.97 mm, and a root-mean-square error of 103.35 mm. CONCLUSIONS: Multiple intraocular components, including the lens, iris, and ciliary body, play important roles in vault determination. The new formula exhibits good accuracy for vault predictions and ICL size recommendations.

20.
Cancer ; 129(10): 1557-1568, 2023 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-36935617

RESUMEN

BACKGROUND: Discrimination can adversely affect health and accelerate aging, but little is known about these relationships in cancer survivors. This study examines associations of discrimination and aging among self-identified African American survivors. METHODS: A population-based sample of 2232 survivors 20-79 years old at diagnosis were enrolled within 5 years of breast (n = 787), colorectal (n = 227), lung (n = 223), or prostate (n = 995) cancer between 2017 and 2022. Surveys were completed post-active therapy. A deficit accumulation index measured aging-related disease and function (score range, 0-1, where <0.20 is robust, 0.20 to <0.35 is pre-frail, and 0.35+ is frail; 0.06 is a large clinically meaningful difference). The discrimination scale assessed ever experiencing major discrimination and seven types of events (score, 0-7). Linear regression tested the association of discrimination and deficit accumulation, controlling for age, time from diagnosis, cancer type, stage and therapy, and sociodemographic variables. RESULTS: Survivors were an average of 62 years old (SD, 9.6), 63.2% reported ever experiencing major discrimination, with an average of 2.4 (SD, 1.7) types of discrimination events. Only 24.4% had deficit accumulation scores considered robust (mean score, 0.30 [SD, 0.13]). Among those who reported ever experiencing major discrimination, survivors with four to seven types of discrimination events (vs. 0-1) had a large, clinically meaningful increase in adjusted deficits (0.062, p < .001) and this pattern was consistent across cancer types. CONCLUSION: African American cancer survivors have high deficit accumulated index scores, and experiences of major discrimination were positively associated with these deficits. Future studies are needed to understand the intersectionality between aging, discrimination, and cancer survivorship among diverse populations.


Asunto(s)
Envejecimiento , Negro o Afroamericano , Supervivientes de Cáncer , Neoplasias , Racismo , Determinantes Sociales de la Salud , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Envejecimiento/etnología , Envejecimiento/fisiología , Negro o Afroamericano/estadística & datos numéricos , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/etnología , Neoplasias de la Mama/fisiopatología , Neoplasias/epidemiología , Neoplasias/etnología , Neoplasias/fisiopatología , Racismo/etnología , Racismo/estadística & datos numéricos , Determinantes Sociales de la Salud/etnología , Determinantes Sociales de la Salud/estadística & datos numéricos , Encuestas y Cuestionarios , Michigan/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA