Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artif Organs ; 48(4): 356-364, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38010063

RESUMEN

BACKGROUND: Infective endocarditis (IE) poses a significant health risk, especially in patients with prosthetic heart valves. Despite advances in treatment, mortality rates remain high. This study aims to investigate the antibacterial properties of a copper titanium dioxide (4× Cu-TiO2) coating on cardiovascular implants against Staphylococcus aureus, a common causative agent of IE. METHODS: Titanium oxide carriers functionalized with copper ions were employed as an antibacterial coating for heart and vascular prostheses. The coating's antibacterial efficacy was assessed using S. aureus ATCC 29213. Microscopic evaluations were conducted on both biological and artificial materials. Antibacterial activity was qualitatively assessed via a modified disc diffusion method and quantitatively measured through colony counts in NaCl suspensions. RESULTS: The coating process was successfully applied to all tested cardiovascular prosthetic materials. Qualitative assessments of antibacterial effectiveness revealed an absence of bacterial growth in the area directly beneath the coated valve. Quantitative evaluations showed a significant reduction in bacterial colonization on coated mechanical valves, with 2.95 × 104 CFU per valve, compared to 1.91 × 105 CFU in control valves. CONCLUSIONS: The 4× Cu-TiO2 coating demonstrated promising antibacterial properties against S. aureus, suggesting its potential as an effective strategy for reducing the risk of bacterial colonization of cardiovascular implants. Further studies are needed to assess the longevity of the coating and its efficacy against other pathogens.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Humanos , Cobre , Staphylococcus aureus , Proyectos Piloto , Materiales Biocompatibles Revestidos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Prótesis e Implantes , Endocarditis Bacteriana/prevención & control , Titanio
2.
Artif Organs ; 48(1): 16-27, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37822301

RESUMEN

BACKGROUND: The management of concomitant valvular lesions in patients undergoing left ventricular assist device (LVAD) implantation remains a topic of debate. This systematic review and meta-analysis aimed to evaluate the existing evidence on postoperative outcomes following LVAD implantation, with and without concomitant MV surgery. METHODS: A systematic database search was conducted as per PRISMA guidelines, of original articles comparing LVAD alone to LVAD plus concomitant MV surgery up to February 2023. The primary outcomes assessed were overall mortality and early mortality, while secondary outcomes included stroke, need for right ventricular assist device (RVAD) implantation, postoperative mitral valve regurgitation, major bleeding, and renal dysfunction. RESULTS: The meta-analysis included 10 studies comprising 32 184 patients. It revealed that concomitant MV surgery during LVAD implantation did not significantly affect overall mortality (OR:0.83; 95% CI: 0.53 to 1.29; p = 0.40), early mortality (OR:1.17; 95% CI: 0.63 to 2.17; p = 0.63), stroke, need for RVAD implantation, postoperative mitral valve regurgitation, major bleeding, or renal dysfunction. These findings suggest that concomitant MV surgery appears not to confer additional benefits in terms of these clinical outcomes. CONCLUSION: Based on the available evidence, concomitant MV surgery during LVAD implantation does not appear to have a significant impact on postoperative outcomes. However, decision-making regarding MV surgery should be individualized, considering patient-specific factors and characteristics. Further research with prospective studies focusing on specific patient populations and newer LVAD devices is warranted to provide more robust evidence and guide clinical practice in the management of valvular lesions in LVAD recipients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Enfermedades Renales , Insuficiencia de la Válvula Mitral , Accidente Cerebrovascular , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Corazón Auxiliar/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Hemorragia/complicaciones , Enfermedades Renales/complicaciones , Estudios Retrospectivos
3.
Thorac Cardiovasc Surg ; 72(2): 134-141, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37506731

RESUMEN

BACKGROUND: Computational fluid dynamics (CFD) simulations model blood flow in aortic pathologies. The aim of our study was to understand the local hemodynamic environment at the site of rupture in distal stent graft-induced new entry (dSINE) after frozen elephant trunk with a clinically time efficient steady-flow simulation versus transient simulations. METHODS: Steady-state simulations were performed for dSINE, prior and after its development and prior to aortic rupture. To account for potential turbulences due geometric changes at the dSINE location, Reynolds-averaged Navier-Stokes equations with the realizable k-ε model for turbulences were applied. Transient simulations were performed for comparison. Hemodynamic parameters were assessed at various locations of the aorta. RESULTS: Post-dSINE, jet-like flow due to luminal narrowing was observed which increased prior to rupture and resulted in focal neighbored regions of high and low wall shear stress (WSS). Prior to rupture, aortic diameter at the rupture site increased lowering WSS at the entire aortic circumference. Concurrently, WSS and turbulence increased locally above the entry tear at the inner aortic curvature. Turbulent kinetic energy and WSS elevation in the downstream aorta demonstrated enhanced stress on the native aorta. Results of steady-state simulations were in good qualitative agreement with transient simulations. CONCLUSION: Steady-flow CFD simulations feasible at clinical time scales prior to aortic rupture reveal a hostile hemodynamic environment at the dSINE rupture site in agreement with lengthy transient simulations. Consequently, our developed approach may be of value in treatment planning where a fast assessment of the local hemodynamic environment is essential.


Asunto(s)
Rotura de la Aorta , Humanos , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/etiología , Rotura de la Aorta/cirugía , Modelos Cardiovasculares , Resultado del Tratamiento , Hemodinámica , Simulación por Computador , Stents , Estrés Mecánico , Hidrodinámica
4.
Artif Organs ; 47(3): 481-489, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36219511

RESUMEN

BACKGROUND: Bioengineered transplantable heart-lung scaffolds could be potentially lifesaving in a large number of congenital and acquired cardiothoracic disorders including terminal heart-lung disease. METHODS: We decellularized heart-lung organ-blocks from rats (n = 10) by coronary and tracheal perfusion with ionic detergents in a modified Langendorff circuit. RESULTS: In the present project, we were able to achieve complete decellularization of the heart-lung organ-block. Decellularized heart-lung organ-blocks lacked intracellular components but maintained structure of the cellular walls with collagen and elastic fibers. CONCLUSIONS: We present a novel model of combined perfusion and decellularization of heart-lung organ-blocks. This model is the first step on the pathway to creating bioengineered transplantable heart-lung scaffolds. We believe that further development of this technology could provide a life-saving conduit, significantly reducing the risks of heart-lung failure surgery and improving postoperative quality of life.


Asunto(s)
Ingeniería de Tejidos , Andamios del Tejido , Ratas , Animales , Andamios del Tejido/química , Calidad de Vida , Matriz Extracelular/química , Pulmón , Perfusión
5.
Artif Organs ; 47(8): 1250-1261, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37086154

RESUMEN

BACKGROUND: Left ventricular assist devices (LVADs) represent an important therapeutic option for patients progressing to end-stage heart failure. LVAD has previously been shown to have a promising role in improving mitral regurgitation (MR). Nevertheless, the prognostic value of preoperative uncorrected MR in this population remains unclear. METHODS: A systematic database search with meta-analysis was conducted of comparative original articles of patients with preoperative mild MR (Grade 0-I) versus moderate-severe MR (Grade II-III) undergoing LVAD implantation, in EMBASE, MEDLINE, Cochrane database, and Google Scholar, from inception to June 2022. Primary outcomes were overall and operative mortality. Secondary outcomes were neurological dysfunction, gastrointestinal bleeding, right heart failure, LVAD thrombosis, and driveline infection. RESULTS: Our search yielded 2228 relevant studies. A total of 19 studies met the inclusion criteria with a total of 11 873 patients. LVAD caused a statistically significant decrease of 35.9% in the number of patients with moderate-severe MR (grade II-III) postoperatively. No significant difference was observed in terms of overall mortality, operative mortality, GI bleeding, LVAD thrombosis, and driveline infection rates between mild and moderate-severe MR. An increased rate of right heart failure was seen among patients with moderate-severe MR, while lower rates of neurological events were also observed. CONCLUSION: LVAD improves the haemodynamics of the left ventricle, to promote resolution of MR. Nevertheless, the severity of preoperative mitral regurgitation in patients undergoing LVAD deployment does not seem to affect mortality.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Pronóstico , Corazón Auxiliar/efectos adversos , Resultado del Tratamiento , Estudios Retrospectivos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía
6.
Artif Organs ; 47(2): 273-289, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36461903

RESUMEN

BACKGROUND: Left ventricular assist devices (LVAD) represent an important therapeutic option for patients progressing to end-stage heart failure. Women have been historically underrepresented in LVAD studies, and have been reported to have worse outcomes despite technological optimisation. We aimed to systematically explore the evidence on sex disparities in the use and outcomes of LVAD implantation. METHODS: A systematic database search with meta-analysis was conducted of comparative original articles of men versus women undergoing LVAD implantation, in EMBASE, MEDLINE, Cochrane database and Google Scholar, from inception to July 2022. Primary outcomes were stroke (haemorrhagic and ischaemic) and early/overall mortality. Secondary outcomes were LVAD thrombosis, right VAD implantation, major bleeding, kidney dysfunction, and device/driveline infection. RESULTS: Our search yielded 137 relevant studies, including 22 meeting the inclusion criteria with a total of 53 227 patients (24.2% women). Overall mortality was higher in women (odds ratio [OR] 1.35, 95% confidence interval [CI] 1.05-1.62, p = 0.02), as was overall stroke (OR 1.32, 95%CI 1.06-1.66, p = 0.01), including ischemic (OR 1.80, 95%CI 1.22-2.64, p = 0.003) and haemorrhagic (OR 1.72, 95%CI 1.09-2.70, p = 0.02). Women had more frequent right VAD implantation (OR 2.11, 95%CI 1.24-3.57, p = 0.006) and major bleeding (OR 1.40, 95%CI 1.06-1.85, p = 0.02). Kidney dysfunction, LVAD thrombosis, and device/driveline infections were comparable between sexes. CONCLUSIONS: Our analysis suggests that women face a greater risk of adverse events and mortality post-LVAD implantation. Although the mechanisms remain unclear, the difference in outcomes is thought to be multifactorial. Further research, that includes comprehensive pre-operative characteristics and post-operative outcomes, is encouraged.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular , Procedimientos Quirúrgicos Torácicos , Masculino , Humanos , Femenino , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/complicaciones , Accidente Cerebrovascular/etiología , Hemorragia/etiología , Estudios Retrospectivos , Resultado del Tratamiento
7.
Medicina (Kaunas) ; 59(6)2023 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-37374330

RESUMEN

Background and Objectives: Sutureless aortic valve prostheses have presented favorable hemodynamic performance while facilitating minimally invasive access approaches. As the population ages, the number of patients at risk for aortic valve reoperation constantly increases. The aim of the present study is to present our single-center experience in sutureless aortic valve replacement (SU-AVR) in reoperations. Materials and Methods: The data of 18 consecutive patients who underwent SU-AVR in a reoperation between May 2020 and January 2023 were retrospectively analyzed. Results: The mean age of the patients was 67.9 ± 11.1 years; patients showed a moderate-risk profile with a median logistic EuroSCORE II of 7.8 (IQR of 3.8-32.0) %. The implantation of the Perceval S prosthesis was technically successful in all patients. The mean cardiopulmonary bypass time was 103.3 ± 50.0 min, and the cross-clamp time was 69.1 ± 38.8 min. No patients required a permanent pacemaker implantation. The postoperative gradient was 7.3 ± 2.4 mmHg, and no cases of paravalvular leakage were observed. There was one case of intraprocedural death, while the thirty-day mortality was 11%. Conclusions: Sutureless bioprosthetic valves tend to simplify the surgical procedure of a redo AVR. By maximizing the effective orifice area, sutureless valves may present an important advantage, being a safe and effective alternative not only to traditional surgical prostheses but also to transcatheter valve-in-valve approaches in select cases.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Persona de Mediana Edad , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Diseño de Prótesis
8.
Br J Surg ; 109(11): 1053-1062, 2022 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-35945894

RESUMEN

BACKGROUND: Machine learning is a set of models and methods that can automatically detect patterns in vast amounts of data, extract information, and use it to perform decision-making under uncertain conditions. The potential of machine learning is significant, and breast surgeons must strive to be informed with up-to-date knowledge and its applications. METHODS: A systematic database search of Embase, MEDLINE, the Cochrane database, and Google Scholar, from inception to December 2021, was conducted of original articles that explored the use of machine learning and/or artificial intelligence in breast surgery in EMBASE, MEDLINE, Cochrane database and Google Scholar. RESULTS: The search yielded 477 articles, of which 14 studies were included in this review, featuring 73 847 patients. Four main areas of machine learning application were identified: predictive modelling of surgical outcomes; breast imaging-based context; screening and triaging of patients with breast cancer; and as network utility for detection. There is evident value of machine learning in preoperative planning and in providing information for surgery both in a cancer and an aesthetic context. Machine learning outperformed traditional statistical modelling in all studies for predicting mortality, morbidity, and quality of life outcomes. Machine learning patterns and associations could support planning, anatomical visualization, and surgical navigation. CONCLUSION: Machine learning demonstrated promising applications for improving breast surgery outcomes and patient-centred care. Neveretheless, there remain important limitations and ethical concerns relating to implementing artificial intelligence into everyday surgical practices.


Asunto(s)
Inteligencia Artificial , Neoplasias de la Mama , Neoplasias de la Mama/cirugía , Bases de Datos Factuales , Femenino , Humanos , Aprendizaje Automático , Calidad de Vida
9.
Artif Organs ; 46(8): 1689-1694, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35377470

RESUMEN

BACKGROUND: With the rapid development of mechanical circulatory support technologies, patients presenting with cardiogenic shock have gained access to various treatment opportunities which were not until recently available. The Impella® pump (Abiomed, Danvers, USA) is a minimally invasive device which provides excellent left ventricular unloading and full circulatory support. The aim of the study was to review our center's experience with Impella® and to analyze the major adverse events associated with the device. METHODS: From January 2020 to January 2022, a total of 32 patients underwent Impella® implantation at our center for various indications. RESULTS: The mean age at surgery was 60.3 ± 12.4 years and 9.4% were female. All patients presented with acute cardiogenic shock in INTERMACS Class I (53.1%) and INTERMACS Class II (46.9%). Twenty-six patients (81.25%) out of the whole cohort have been mobilized on Impella® support. Seventeen patients (53.1%) have been weaned from the Impella® support and 10 patients (31.3%) have been bridged to durable LVAD. The median time on Impella® was 7 days (IQR 5.0-11.0). 30-day mortality was 37.5%, with 56.25% survival until hospital discharge. Only one patient developed vascular complications consisting of arm hypoperfusion. There were no cases of stroke on Impella® support. CONCLUSION: The Impella® axial-flow pump seems an appropriate therapeutic option for patients with acute cardiogenic shock requiring partial or full hemodynamic support. It also provides sufficient left ventricular unloading to allow full mobilization and neurological assessment of the patients. Furthermore, Impella® offers a high rate of myocardial recovery.


Asunto(s)
Corazón Auxiliar , Choque Cardiogénico , Femenino , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Sistema de Registros , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía , Resultado del Tratamiento
10.
Artif Organs ; 46(5): 953-963, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34931335

RESUMEN

BACKGROUND: Mitral valve regurgitation (MR) is a common finding in patients with end-stage heart failure. The aim of the study was to analyze the impact of preoperative moderate-to-severe MR on postoperative outcomes and survival after durable left-ventricular assist device (LVAD) implantation. METHODS: From August 2010 to May 2021, 246 patients underwent a durable LVAD implantation. We stratified the patients into two groups: Group A (n = 109) presented with MR 0-I°, and Group B presented with MR II-III° (n = 137). MR II-III° was defined according to the current recommendations (i.e., vena contracta ≥ 7 mm, regurgitation volume ≥ 30 ml or effective regurgitation orifice area ≥ 20 mm2 ). RESULTS: Significantly more patients in Group B suffered from pulmonary hypertension and presented with chronic obstructive lung disease. We observed significantly higher rates of tricuspid regurgitation (TR) II-III° in Group B (76.1%) versus Group A (14.8%) (p < 0.001) and TR III° in Group B (30.4%) versus Group A (3.7%) (p < 0.001). There was no difference in the incidence of right heart failure between the groups. Within our cohort, the in-hospital, 1-year, 3-year, and 5-year mortality was 22.4%, 32.1%, 50.7%, and 64.4%, respectively. Group B showed significantly worse overall survival (p = 0.05). Patients with preoperative TR II-III° had a significantly worse survival than those with TR 0-I° (p = 0.048). In patients presenting with MR II-III°, we discovered that TR III° seems to predict both in-hospital and mid-term mortality. CONCLUSION: MR II-III° negatively affects the outcomes in patients requiring LVAD implantation. Persisting MR II-III° is an independent predictor of mortality. Patients with concomitant preoperative TR II-III° are at increased risk of developing postoperative major adverse events. Addressing the MR might be considered for these patients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
11.
Artif Organs ; 46(1): 95-105, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34694644

RESUMEN

BACKGROUND: The use of left ventricular assist devices (LVAD) in patients with advance heart failure is still associated with an important risk of immune dysregulation and infections. The aim of this study was to determine whether extracorporeal blood purification using the CytoSorb device benefits patients after LVAD implantation in terms of complications and overall survival. MATERIALS AND METHODS: Between August 2010 and January 2020, 207 consecutive patients underwent LVAD implantation, of whom 72 underwent CytoSorb therapy and 135 did not. Overall survival, major adverse events, and laboratory parameters were compared between 112 propensity score-matched patients (CytoSorb: 72 patients; non-CytoSorb: 40 patients). RESULTS: WBC (p = .033), CRP (p = .001), and IL-6 (p < .001), significantly increased with LVAD implantation, while CytoSorb did not influence this response. In-hospital mortality and overall survival during follow-up were similar with CytoSorb. However, patients treated with CytoSorb were more likely to develop respiratory failure (54.2% vs. 30.0%, p = .024), need mechanical ventilation for longer than 6 days post-implant (50.0% vs. 27.5%, p = .035), and require tracheostomy during hospitalization (31.9% vs. 12.5%, p = .040). No other significant differences were observed with regard to major adverse events during follow-up. CONCLUSIONS: Overall, our results showed that CytoSorb might not convey a significant morbidity or mortality benefit for patients undergoing LVAD implantation.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Hemofiltración/instrumentación , Proteína C-Reactiva/análisis , Femenino , Hemofiltración/métodos , Mortalidad Hospitalaria , Humanos , Interleucina-6/sangre , Recuento de Leucocitos , Masculino , Persona de Mediana Edad , Respiración Artificial/estadística & datos numéricos , Insuficiencia Respiratoria , Estudios Retrospectivos , Traqueotomía/estadística & datos numéricos , Resultado del Tratamiento
12.
J Card Surg ; 37(1): 258-259, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34318536

RESUMEN

Redo mitral valve replacement remains the standard treatment for recurrent mitral valve disease. Most patients referred for a redo surgery in the western world are older and present with multiple comorbidities. With the successful broad implementation of anti-infective treatment, rheumatic mitral valve disease has become highly uncommon. Nonetheless, rheumatic heart disease is still thriving in developing countries causing the most severe mitral valve conditions. The guidelines are there to help us in our decision-making process, but the actual decision has to be made based on each patients' individual criteria.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Cardiopatía Reumática , Países en Desarrollo , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Válvula Mitral/cirugía , Reoperación , Cardiopatía Reumática/cirugía , Resultado del Tratamiento
13.
J Card Surg ; 37(4): 1121-1124, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35076101

RESUMEN

Since the development of endoscopic vision in the late 1970s, the implementation of minimally invasive surgical methods has been rapidly progressing throughout a wide range of surgical disciplines, including cardiovascular surgery. The benefits of minimally invasive procedures including a reduction in operative trauma and postoperative morbidity, have been well-documented and compared to open-heart procedures, eventually becoming the preferred modality of treatment by many centers. Due to the cost ineffectiveness of the robotic systems for numerous institutions, new technologies have been developed to provide the advantages of robotic surgical systems at a lower price, thus making them more widely available. In this paper, we aimed to share our first experiences with Artisential® surgeon-powered robotic instruments and review their general advantages compared to conventional and robotic devices.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Cirujanos , Endoscopía/métodos , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Procedimientos Quirúrgicos Robotizados/métodos , Robótica/métodos
14.
Minim Invasive Ther Allied Technol ; 31(6): 909-916, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34915823

RESUMEN

BACKGROUND: We aimed to evaluate the outcomes of transapical and transaortic transcatheter aortic valve replacement (TAVR) in high-risk patients who were not suitable for transfemoral access and had a logistic EuroSCORE-I ≥ 25% and Society of Thoracic Surgeons (STS) score >6%. 'STS/ACC TAVR In-Hospital Mortality Risk App' was evaluated. MATERIAL AND METHODS: Between January 2016 and May 2020, 126 patients at very high risk for aortic valve replacement underwent transapical (n = 121) or transaortic (n = 5) transcatheter aortic valve replacement. TAVR was performed using SAPIEN 3™ or ACURATE TA™ prosthesis. RESULTS: The logistic EuroSCORE-I was 40.6 ± 14.0%, the STS-score 7.9 ± 4.6%, and STS/ACC-score 8.4 ± 3.4%. Valve implantation was successful in all patients. Operative, in-hospital and 30-days mortality, were 0, 7.9, and 13.5%, respectively. Survival was 72% at one year and 48% at four years. Expected/observed in-hospital mortality was 1.0 for the STS-score and 1.06 for the STS/ACC-score. Renal failure, low ejection fraction, and postoperative acute kidney injury, hemorrhage, and vascular complications were identified as independent predictors for 30-day mortality. CONCLUSIONS: Transapical and transaortic TAVR in high-risk patients unsuitable for transfemoral access is still a reasonable alternative in these patients. STS and STS/ACC-score appear to be highly accurate in predicting in-hospital mortality in high-risk patients undergoing TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Artif Organs ; 45(7): 706-716, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33350481

RESUMEN

The use of left ventricular assist devices (LVADs) for advanced heart failure is becoming increasingly common. However, optimal timing and patient selection remain controversial. The aim of this study was to investigate outcomes of LVAD implantation for advanced heart failure in critically ill patients (INTERMACS 1 and 2). Between August 2010 and January 2020, 207 consecutive patients underwent LVAD implantation. Overall survival, major adverse events, and laboratory parameters were compared between patients in INTERMACS 1-2 (n = 107) and INTERMACS 3-5 (n = 100). Preoperative white blood cells, C-reactive protein, procalcitonin, bilirubin, alanine transaminase, and lactate dehydrogenase were all significantly higher in INTERMACS 1-2 when compared to INTERMACS 3-5 (P < .05). During hospitalization following LVAD implantation, patients in INTERMACS 1-2 were more likely to develop major infections (41.1% vs. 23.0%, P = .005), respiratory failure (57.9% vs. 25.0%, P < .001), mild (20.6% vs. 8.0%, P = .010), and moderate (31.8% vs. 7.0%, P < .001) right heart failure, and acute renal dysfunction (56.1% vs. 6.0%, P < .001). During a median follow-up of 2.00 years (interquartile range (IQR) 0.24-3.39 years), they had a higher incidence of thoracic (15.9% vs. 4.0%, P = .005) and gastrointestinal bleeding (21.5% vs. 11.0%, P = .042), as well as right heart failure (18.7% vs. 1%, P < .001). Risk of death was significantly higher in the INTERMACS 1-2 group (hazards ratio (HR) 1.64, 95% CI 1.12-2.40, P = .011). LVAD implantation in critically ill patients is associated with increased morbidity and mortality. Our results suggest that decision for LVAD should be not be delayed until INTERMACS 1 and 2 levels whenever possible.


Asunto(s)
Enfermedad Crítica/clasificación , Insuficiencia Cardíaca/clasificación , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Lesión Renal Aguda/epidemiología , Anciano , Femenino , Estudios de Seguimiento , Hemorragia/epidemiología , Humanos , Infecciones/epidemiología , Masculino , Persona de Mediana Edad , Insuficiencia Respiratoria/epidemiología , Estudios Retrospectivos
16.
J Card Surg ; 36(7): 2476-2485, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33797789

RESUMEN

INTRODUCTION: Primary cardiac sarcomas (PCSs) are an extremely rare and aggressive type of malignancies that have been described only by a limited number of observational studies. This study aimed to evaluate the currently existing evidence comparing surgical to multimodality treatment of PCS. METHODS: We systematically reviewed Embase, MEDLINE, Cochrane Database, and Google Scholar, from inception to December 2020, for original articles about surgical and multimodality treatment of PCS. The outcomes included were mortality at various time points, resection margin status, and mean estimated survival. The pooled treatment effects were calculated using a random-effects model. RESULTS: Ten studies including a total of 1570 patients met our inclusion criteria. Surgery was associated with significantly lower mortality when compared to conservative treatment at 1, 2, and 3 years, whereas no significant difference was found at 5 years. Furthermore, multimodality treatment showed significantly lower mortality at 1 year when compared to surgery alone, but not at 2 and 5 years. We found no difference in mortality between angiosarcomas and other PCS subtypes. CONCLUSION: Overall, surgery was found to provide a significant mortality advantage to PCS patients up to 3 years following treatment. Multimodality treatment might be of additional benefit, although only within the first year. Prospective randomized studies are needed to further explore these differences in the treatment of PCS.


Asunto(s)
Neoplasias Cardíacas , Sarcoma , Terapia Combinada , Neoplasias Cardíacas/cirugía , Humanos , Estudios Prospectivos , Sarcoma/cirugía
17.
J Card Surg ; 36(9): 3195-3204, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34227147

RESUMEN

INTRODUCTION: Redo surgical mitral valve replacement (SMVR) remains the gold standard treatment in patients with a history of mitral valve surgery presenting with recurrent mitral valve pathologies. Whilst this procedure is demanding, it is an inevitable intervention for some indications, such as infective endocarditis, thrombosis, or multivalve procedures. In this study, we aim to evaluate our institutional experience with SMVR on a real-life cohort, identifying the factors that contribute to poor surgical outcomes whilst avoiding selection bias. METHODS: Between March 2012 and November 2020, 58 consecutive high-risk patients underwent a redo SMVR at our institution. The primary endpoints of this study were 30-day and 1-year mortality. The secondary endpoint was the development of any postoperative adverse events. We analyzed and compared the survival in patients undergoing an isolated SMVR and in those that required at least one concomitant procedure. RESULTS: The overall operative, 30-day, and 1-year mortality were 3.4%, 22.4%, and 25.9%, respectively. The mortality in patients undergoing isolated SMVR was significantly lower than in patients requiring concomitant procedures. The multivariable regression model showed that NYHA Class IV, infective endocarditis, and postoperative dialysis were significantly associated with 30-day mortality. Society of Thoracic Surgeons Score, infective endocarditis, concomitant procedures, and mechanical valve implantation appeared to predict long-term mortality. CONCLUSION: This study illustrates that SMVR after prior mitral valve surgery presents a demanding procedure with high operative risk, significant mortality, and morbidity. Whilst this procedure is inevitable for some indications, a careful patient selection and risk stratification provides acceptable surgical results in this cohort.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Humanos , Válvula Mitral/cirugía , Diálisis Renal , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
18.
J Card Surg ; 36(1): 286-289, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33085137

RESUMEN

In rare cases of extensive aortic root or mitral valve infective endocarditis (IE), severe calcification of the aortic and mitral valves, or double-valve procedures in patients with small aortic and mitral annuli, surgical reconstruction of the intervalvular fibrous body (IVFB) is required. A high mortality is generally associated with this procedure, and it is frequently avoided by surgeons due to a lack of experience. It is crucial to radically resect all tissues that are severely affected by IE to prevent recurrence in the patient. Our experience with the Commando procedure in patients with extensive double-valve IE involving the IVFB is presented in this article.


Asunto(s)
Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Procedimientos de Cirugía Plástica , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Endocarditis/cirugía , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía
19.
J Card Surg ; 36(4): 1226-1231, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33491207

RESUMEN

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) techniques are increasingly being adopted into clinical routine for various risk groups. Coronary artery disease (CAD) is seen in up to 75% of patients with severe aortic valve stenosis (AS) presenting with typical angina pectoris. Due to high mortality rates and procedural complications in these patients, a hybrid concept of simultaneous transaortic TAVI and off-pump coronary artery bypass (OPCAB) can be a feasible treatment option. METHODS: Between April 2014 and July 2020, 10 consecutive high-risk patients underwent concomitant transaortic TAVI and OPCAB at our institution. All indications were discussed in Heart Team and decisions were made based on patients' comorbidities and complexity of CAD. The study endpoints were 30-day mortality, device success, and development of postoperative adverse events defined by the Valve Academic Research Consorium. RESULTS: The mean age of the patients was 77.9 ± 7.1 years old. All patients presented with multiple comorbidities (mean logistic EuroSCORE 26.5 ± 12.3%, median EuroSCORE II 5.13% [interquartile range 4.2-9.5], mean STS-Score 6.04 ± 1.6%). Five patients (50%) presented with porcelain aorta. No conversion to conventional procedures was needed. 30-day mortality occurred in one patient (10%). Complete revascularization was achieved in seven (70%) of the patients. Device success rate was 100%. No paravalvular leakage was detected. No stroke, myocardial infarction or vascular complications were observed. CONCLUSIONS: A hybrid approach combining transaortic TAVI and OPCAB might be a safe and feasible method of treatment in high-risk patients presenting with severe AS and CAD who are not eligible for conventional surgical or interventional solutions.


Asunto(s)
Estenosis de la Válvula Aórtica , Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
20.
J Card Surg ; 35(1): 195-199, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31609509

RESUMEN

BACKGROUND: Cardiogenic shock (CS) from biventricular heart failure that requires acute mechanical circulatory support (MCS) is associated with high mortality. Different MCS methods and techniques have emerged as a standard of care in CS. Nevertheless, the routine MCS approach carries multiple limitations such as limb ischemia, missing of left ventricular unloading and immobilization. We describe a method to establish a groin-free full support MCS in patients with CS without the need for thoracotomy. This is the first report of the ECPELLA 2.0 concept, a peripheral groin-free biventricular MCS in patients with acute CS. METHODS AND RESULTS: We discuss two patients in acute CS (INTERMACS I) treated with two peripheral MCS devices (Impella 5.0 or 5.5 surgically via an axillary artery and ProtekDuo cannula percutaneously via a right internal jugular vein) as a bridge before the implantation of a durable left ventricular assist device (LVAD). Biventricular assist device (BIVAD)-support duration was 9 and 15 days and both of the patients were successfully bridged to a durable LVAD. As our BIVAD-concept is groin-free, the patients started full mobilization as early as they were weaned from the respirator 2 days after the BIVAD-implantation. ECPELLA 2.0 provides a high cardiac output, right and left ventricular unloading with end-organ recovery and a possibility of administration of a membrane oxygenator. There were no device-related complications. CONCLUSION: The ECPELLA 2.0 biventricular support concept for patients suffering from an acute CS. Allows for rapid extubation, mobilization, and physical exercise while on full support. Additional application of a membrane oxygenator is easily feasible if required.


Asunto(s)
Cánula , Corazón Auxiliar , Choque Cardiogénico/terapia , Enfermedad Aguda , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA