Resultados 1 - 16 de 16
Filtrar
1.
Clin Chem Lab Med ; 62(1): 50-59, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-37327361

RESUMEN

OBJECTIVES: Faecal immunochemical tests for haemoglobin (FIT) are used in colorectal cancer screening programs around the world and increasingly for triage of symptomatic patients. FIT results are currently not traceable to a common reference standard and results obtained on various FIT systems may not be equivalent. The size of the bias between the systems is difficult to quantify due to the complex pre-analytical aspects of FIT. METHODS: This study aimed to quantify the bias and the correlation between four FIT systems by measuring a panel of 38 faecal samples while limiting the effect of the pre-analytical aspects. In addition, the commutability of seven candidate reference materials (RM) was assessed. RESULTS: Pairwise method comparisons based on faecal samples demonstrated Pearson correlation coefficients ranging between 0.944 and 0.970 and an average proportional bias of -30 to -35 % for one FIT system compared to the other three. The relative standard deviation among biases of the individual samples was around 20 %. Due to these sample specific differences, no decisive conclusions could be drawn in the commutability study. However, two candidate RMs, prepared in the FIT system-specific storage/extraction buffers, had a better commutable profile than the other five. CONCLUSIONS: The use of a common threshold for all FIT systems is currently not possible due to the presence of a proportional bias. We have identified potential commutable RMs to take to further studies on the production of a common calibrator, with the aim being to reduce the analytical bias observed on different FIT systems.


Asunto(s)
Neoplasias Colorrectales , Sangre Oculta , Humanos , Estándares de Referencia , Neoplasias Colorrectales/diagnóstico , Sesgo , Calibración , Hemoglobinas
2.
Pediatr Res ; 90(2): 272-276, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33941863

RESUMEN

Severe neonatal hyperbilirubinemia (SNH) is a serious condition that occurs worldwide. Timely recognition with bilirubin determination is key in the management of SNH. Visual assessment of jaundice is unreliable. Fortunately, transcutaneous bilirubin measurement for screening newborn infants is routinely available in many hospitals and outpatient settings. Despite a few limitations, the use of transcutaneous devices facilitates early recognition and appropriate management of neonatal jaundice. Unfortunately, however, advanced and often costly screening modalities are not accessible to everyone, while there is an urgent need for inexpensive yet accurate instruments to assess total serum bilirubin (TSB). In the near future, novel icterometers, and in particular optical bilirubin estimates obtained with a smartphone camera and processed with a smartphone application (app), seem promising methods for screening for SNH. If proven reliable, these methods may empower outpatient health workers as well as parents at home to detect jaundice using a simple portable device. Successful implementation of ubiquitous bilirubin screening may contribute substantially to the reduction of the worldwide burden of SNH. The benefits of non-invasive bilirubin screening notwithstanding, any bilirubin determination obtained through non-invasive screening must be confirmed by a diagnostic method before treatment. IMPACT: Key message: Screening methods for neonatal hyperbilirubinemia facilitate early recognition and timely treatment of severe neonatal hyperbilirubinemia (SNH). Any bilirubin screening result obtained must be confirmed by a diagnostic method. What does this article add to the existing literature? Data on optical bilirubin estimation are summarized. Niche research strategies for prevention of SNH are presented. Impact: Transcutaneous screening for neonatal hyperbilirubinemia contributes to the prevention of SNH. A smartphone application with optical bilirubin estimation seems a promising low-cost screening method, especially in low-resource settings or at home.


Asunto(s)
Bilirrubina/sangre , Hiperbilirrubinemia Neonatal/diagnóstico , Ictericia Neonatal/diagnóstico , Tamizaje Neonatal , Biomarcadores/sangre , Diagnóstico Precoz , Humanos , Hiperbilirrubinemia Neonatal/sangre , Hiperbilirrubinemia Neonatal/terapia , Recién Nacido , Ictericia Neonatal/sangre , Ictericia Neonatal/terapia , Aplicaciones Móviles , Tamizaje Neonatal/instrumentación , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Teléfono Inteligente , Regulación hacia Arriba
3.
Pediatr Res ; 90(2): 277-283, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33948000

RESUMEN

Invasive bilirubin measurements remain the gold standard for the diagnosis and treatment of infants with severe neonatal hyperbilirubinemia. The present paper describes different methods currently available to assess hyperbilirubinemia in newborn infants. Novel point-of-care bilirubin measurement methods, such as the BiliSpec and the Bilistick, would benefit many newborn infants, especially in low-income and middle-income countries where the access to costly multi-analyzer in vitro diagnostic instruments is limited. Total serum bilirubin test results should be accurate within permissible limits of measurement uncertainty to be fit for clinical purposes. This implies correct implementation of internationally endorsed reference measurement systems as well as participation in external quality assessment programs. Novel analytic methods may, apart from bilirubin, include the determination of bilirubin photoisomers and bilirubin oxidation products in blood and even in other biological matrices. IMPACT: Key message: Bilirubin measurements in blood remain the gold standard for diagnosis and treatment of severe neonatal hyperbilirubinemia (SNH). External quality assessment (EQA) plays an important role in revealing inaccuracies in diagnostic bilirubin measurements. What does this article add to the existing literature? We provide analytic performance data on total serum bilirubin (TSB) as measured during recent EQA surveys. We review novel diagnostic point-of-care (POC) bilirubin measurement methods and analytic methods for determining bilirubin levels in biological matrices other than blood. Impact: Manufacturers should make TSB test results traceable to the internationally endorsed total bilirubin reference measurement system and should ensure permissible limits of measurement uncertainty.


Asunto(s)
Bilirrubina/sangre , Hiperbilirrubinemia Neonatal/diagnóstico , Ictericia Neonatal/diagnóstico , Tamizaje Neonatal , Pruebas en el Punto de Atención , Biomarcadores/sangre , Humanos , Hiperbilirrubinemia Neonatal/sangre , Hiperbilirrubinemia Neonatal/terapia , Recién Nacido , Ictericia Neonatal/sangre , Ictericia Neonatal/terapia , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Regulación hacia Arriba
4.
Clin Chem Lab Med ; 59(5): 965-970, 2021 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-33554536

RESUMEN

OBJECTIVES: Hemoglobin A1c (HbA1c) is a valuable parameter in the monitoring of diabetic patients and increasingly in diagnosis of diabetes. Manufacturers continuously optimize instruments, currently the main focus is to achieve faster turnaround times. It is important that performance specifications remain of high enough standard, which is evaluated in this study for the new ARKRAY HA-8190V instrument. METHODS: The Clinical and Laboratory Standards Institute (CLSI) protocols EP-5, EP-9 and EP-10 were applied to investigate imprecision, bias and linearity. In addition potential interferences, performance in External Quality Assessment (EQA) and performance against the HA-8180V instrument in 220 clinical samples was evaluated. RESULTS: The HA-8190V demonstrates a CV of ≤0.8% in IFCC SI units (≤0.6% National Glycohemoglobin Standardization Program [NGSP]) at 34 and 102 mmol/mol levels (5.3 and 11.5% NGSP) and a bias of -0.1 mmol/mol (-0.01% NGSP) at a concentration of 50 mmol/mol (6.7% NGSP), but with a significant slope as compared to target values. This results in a bias of -1.0 and 0.9 mmol/mol (-2.0 and 0.9% NGSP) at the 30 and 70 mmol/mol (4.9 and 8.6% NGSP) concentration level. Simulation of participation in the IFCC certification programme results in a Silver score (bias -0.1 mmol/mol, CV 1.1%). Interference in the presence of the most important Hb variants (AS, AC, AE, AD) and elevated HbA2 and HbF concentrations is less than 3 mmol/mol (0.3% NGSP) at a concentration of 50 mmol/mol (6.7% NGSP). CONCLUSIONS: Analytical performance of the HA-8190V is very good, especially with respect to precision and HbA1c quantification in the presence of the most common Hb variants.


Asunto(s)
Diabetes Mellitus , Hemoglobina Glucada/análisis , Humanos , Estándares de Referencia
5.
Clin Chem Lab Med ; 59(1): 117-125, 2020 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-32759402

RESUMEN

Objectives: External quality assessment (EQA) with commutable samples is used for assessing agreement of results for patients' samples. We investigated the feasibility to aggregate results from four different EQA schemes to determine the bias between different measurement procedures and a reference target value. Methods: We aggregated EQA results for creatinine from programs that used commutable EQA material by calculating the relative difference between individual participant results and the reference target value for each sample. The means and standard errors of the means were calculated for the relative differences. Results were partitioned by methods, manufacturers and instrument platforms to evaluate the biases for the measurement procedures. Results: Data aggregated for enzymatic methods had biases that varied from -8.2 to 3.8% among seven instrument platforms for creatinine at normal concentrations (61-85 µmol/L). EQA schemes differed in the evidence provided about the commutability of their samples, and in the amount of detail collected from participants regarding the measurement procedures which limited the ability to sub-divide aggregated data by instrument platforms and models. Conclusions: EQA data could be aggregated from four different programs using different commutable samples to determine bias among different measurement procedures. Criteria for commutability for EQA samples as well as standardization of reporting the measurement methods, reagents, instrument platforms and models used by participants are needed to improve the ability to aggregate the results for optimal assessment of performance of measurement procedures. Aggregating data from a larger number of EQA schemes is feasible to assess trueness on a global scale.


Asunto(s)
Análisis Químico de la Sangre/normas , Creatinina/sangre , Análisis Químico de la Sangre/estadística & datos numéricos , Agregación de Datos , Estudios de Factibilidad , Humanos , Países Bajos , Noruega , Control de Calidad , Reino Unido , Estados Unidos
6.
Clin Chem Lab Med ; 57(12): 1999-2007, 2019 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-31326959

RESUMEN

Background High-sensitivity cardiac troponin T/I (hs-cTnT/I) assays have improved analytical sensitivity for the detection of myocardial infarction (MI). To gain clinical specificity and sensitivity, interpretation of changes in cTn concentrations over time is crucial. The 2015 ESC NSTEMI guideline defines absolute delta values as additional rule-in and rule-out criteria for MI. A critical assumption for application of this rule is that total analytical imprecision within the delta period, including inter-instrument bias, is comparable to analytical imprecision in the validation studies. Methods Data from the Dutch External Quality Assessment Scheme (EQAS) were used to calculate inter-instrument bias and estimate imprecision for the measuring range where the proposed delta values are relevant: for Roche Elecsys hs-cTnT, 5-52 and 5-12 ng/L; for Abbott Architect hs-cTnI, 2-52 and 2-5 ng/L for rule-in and rule-out, respectively. Results For Elecsys, the median inter-instrument bias is 0.3 ng/L (n = 33 laboratories), resulting in reference change values (RCVs) of 3.0 and 1.7 ng/L, respectively, for rule-in and rule-out with imprecision as claimed by the manufacturer. With RCVs smaller than the guideline's delta thresholds, 100% of the laboratories have adequate specifications. RCVs for rule-in/rule-out increased to 4.6 ng/L/2.5 ng/L, respectively, with individual imprecisions as estimated from EQA data, resulting in 64% and 82% of laboratories with adequate specifications. For Architect, 40% of instruments (n = 10) might falsely qualify the result as clinically relevant; hence, inter-instrument bias could not be determined. Conclusions We advise laboratories that use the fast 0/1-h algorithm to introduce stringent internal quality procedures at the relevant/low concentration level, especially when multiple analyzers are randomly used.


Asunto(s)
Análisis Químico de la Sangre/métodos , Infarto del Miocardio sin Elevación del ST/diagnóstico , Troponina T/análisis , Algoritmos , Sesgo , Bioensayo/métodos , Femenino , Humanos , Masculino , Infarto del Miocardio/diagnóstico , Infarto del Miocardio sin Elevación del ST/metabolismo , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo , Troponina I/análisis
8.
Clin Chem Lab Med ; 55(10): 1530-1536, 2017 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-28284032

RESUMEN

BACKGROUND: Measurement of adequate glucose concentrations is complicated by in vitro breakdown of glucose due to glycolysis. Unlike the commonly used NaF-EDTA and NaF-oxalate phlebotomy tubes, citrated NaF-EDTA tubes are reported to directly and thereby completely inhibit glycolysis. Recently, Greiner introduced the Vacuette® FC-Mix NaF-EDTA-citrate tube, currently the only NaF-citrate tube without volume-disturbing liquid additions available on the European market. Here we present its potential as alternative for the laborious and therefore unfeasible conditions for glucose sampling as recommended by the World Health Organization (WHO). METHODS: The FC-Mix tube was tested against the WHO recommended method of optimal laboratory conditions, both in healthy volunteers and pregnant woman undergoing oral glucose tolerance test (oGTT) for screening of gestational diabetes mellitus (GDM). Glucose concentrations were measured after different incubation times (0-48 h) and temperatures (room temperature, 37 °C), both in uncentrifuged whole blood and centrifuged material. RESULTS: Deming regression analysis shows that glucose concentrations measured in the FC-Mix tube correlate to the WHO recommended method. Stability is maintained at room temperature for 48 h and at least 24 h at 37 °C. The use of the FC-Mix tube was also validated in screening for GDM and proved comparable to the WHO recommended method in diagnostic outcome. CONCLUSIONS: The new Greiner FC-Mix tube combines the easy handling of a routine tube with dry additive with the ability to immediately inhibit glycolysis as in the WHO method for optimal pre-analytical and analytical conditions and performs equally to those conditions when screening for GDM.


Asunto(s)
Flebotomía/instrumentación , Adulto , Glucemia/análisis , Citratos/química , Diabetes Gestacional/diagnóstico , Ácido Edético/química , Femenino , Prueba de Tolerancia a la Glucosa , Glucólisis , Hemólisis , Humanos , Flebotomía/métodos , Flebotomía/normas , Embarazo , Fluoruro de Sodio/química , Temperatura
9.
J Biol Chem ; 289(26): 18489-96, 2014 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-24828496

RESUMEN

Epinephrine and norepinephrine are present in the pro-urine. ß-Adrenergic receptor (ß-AR) blockers administered to counteract sympathetic overstimulation in patients with congestive heart failure have a negative inotropic effect, resulting in reduced cardiac contractility. Positive inotropes, ß1-AR agonists, are used to improve cardiac functions. Active Ca(2+) reabsorption in the late distal convoluted and connecting tubules (DCT2/CNT) is initiated by Ca(2+) influx through the transient receptor potential vanilloid type 5 (TRPV5) Ca(2+) channel. Although it was reported that ß-ARs are present in the DCT2/CNT region, their role in active Ca(2+) reabsorption remains elusive. Here we revealed that ß1-AR, but not ß2-AR, is localized with TRPV5 in DCT2/CNT. Subsequently, treatment of TRPV5-expressing mouse DCT2/CNT primary cell cultures with the ß1-AR agonist dobutamine showed enhanced apical-to-basolateral transepithelial Ca(2+) transport. In human embryonic kidney (HEK293) cells, dobutamine was shown to stimulate cAMP production, signifying functional ß1-AR expression. Fura-2 experiments demonstrated increased activity of TRPV5 in response to dobutamine, which could be prevented by the PKA inhibitor H89. Moreover, nonphosphorylable T709A-TRPV5 and phosphorylation-mimicking T709D-TRPV5 mutants were unresponsive to dobutamine. Surface biotinylation showed that dobutamine did not affect plasma membrane abundance of TRPV5. In conclusion, activation of ß1-AR stimulates active Ca(2+) reabsorption in DCT2/CNT; an increase in TRPV5 activity via PKA phosphorylation of residue Thr-709 possibly plays an important role. These data explicate a calciotropic role in addition to the inotropic property of ß1-AR.


Asunto(s)
Canales de Calcio/metabolismo , Subunidades Catalíticas de Proteína Quinasa Dependientes de AMP Cíclico/metabolismo , Receptores Adrenérgicos beta 1/metabolismo , Canales Catiónicos TRPV/metabolismo , Animales , Calcio/metabolismo , Canales de Calcio/genética , Subunidades Catalíticas de Proteína Quinasa Dependientes de AMP Cíclico/genética , Humanos , Lactante , Ratones , Ratones Transgénicos , Receptores Adrenérgicos beta 1/genética , Transducción de Señal , Canales Catiónicos TRPV/genética
10.
Am J Physiol Renal Physiol ; 309(4): F359-68, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26155844

RESUMEN

The anti-aging gene klotho plays an important role in Ca(2+) and phosphate homeostasis. Membrane-bound klotho is an essential coreceptor for fibroblast growth factor-23 and can be cleaved by proteases, including a disintegrin and metalloproteinase (ADAM)10 and ADAM17. Cleavage of klotho occurs at a site directly above the plasma membrane (α-cut) or between the KL1 and KL2 domain (ß-cut), resulting in soluble full-length klotho or KL1 and KL2 fragments, respectively. The aim of the present study was to gain insights into the mechanisms behind klotho cleavage processes in the kidney. Klotho shedding was demonstrated using a Madin-Darby canine kidney cell line stably expressing klotho and human embryonic kidney-293 cells transiently transfected with klotho. Here, we report klotho expression on both the basolateral and apical membrane, with a higher abundance of klotho at the apical membrane and in the apical media. mRNA expression of ADAM17 and klotho were enriched in mouse distal convoluted and connecting tubules. In vitro ADAM/matrix metalloproteinase inhibition by TNF484 resulted in a concentration-dependent inhibition of the α-cut, with a less specific effect on ß-cut shedding. In vivo TNF484 treatment in wild-type mice did not change urinary klotho levels. However, ADAM/matrix metalloproteinase inhibition did increase renal and duodenal mRNA expression of phosphate transporters, whereas serum phosphate levels were significantly decreased. In conclusion, our data show that renal cells preferentially secrete klotho to the apical side and suggest that ADAMs are responsible for α-cut cleavage.


Asunto(s)
Proteínas ADAM/metabolismo , Membrana Celular/enzimología , Glucuronidasa/metabolismo , Riñón/enzimología , Proteínas ADAM/antagonistas & inhibidores , Proteínas ADAM/genética , Proteína ADAM10 , Proteína ADAM17 , Secretasas de la Proteína Precursora del Amiloide/genética , Secretasas de la Proteína Precursora del Amiloide/metabolismo , Animales , Membrana Celular/efectos de los fármacos , Medios de Cultivo Condicionados/metabolismo , Perros , Relación Dosis-Respuesta a Droga , Duodeno/metabolismo , Regulación Enzimológica de la Expresión Génica , Glucuronidasa/genética , Células HEK293 , Humanos , Riñón/efectos de los fármacos , Proteínas Klotho , Células de Riñón Canino Madin Darby , Masculino , Proteínas de la Membrana/genética , Proteínas de la Membrana/metabolismo , Ratones Endogámicos C57BL , Proteínas de Transporte de Fosfato/metabolismo , Fosfatos/sangre , Inhibidores de Proteasas/farmacología , Procesamiento Proteico-Postraduccional , ARN Mensajero/metabolismo , Transfección
11.
Pflugers Arch ; 466(11): 2077-87, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24557712

RESUMEN

Fine-tuning of renal calcium ion (Ca(2+)) reabsorption takes place in the distal convoluted and connecting tubules (distal convolution) of the kidney via transcellular Ca(2+) transport, a process controlled by the epithelial Ca(2+) channel Transient Receptor Potential Vanilloid 5 (TRPV5). Studies to delineate the molecular mechanism of transcellular Ca(2+) transport are seriously hampered by the lack of a suitable cell model. The present study describes the establishment and validation of a primary murine cell model of the distal convolution. Viable kidney tubules were isolated from mice expressing enhanced Green Fluorescent Protein (eGFP) under the control of a TRPV5 promoter (pTRPV5-eGFP), using Complex Object Parametric Analyser and Sorting (COPAS) technology. Tubules were grown into tight monolayers on semi-permeable supports. Radioactive (45)Ca(2+) assays showed apical-to-basolateral transport rates of 13.5 ± 1.2 nmol/h/cm(2), which were enhanced by the calciotropic hormones parathyroid hormone and 1,25-dihydroxy vitamin D3. Cell cultures lacking TRPV5, generated by crossbreeding pTRPV5-eGFP with TRPV5 knockout mice (TRPV5(-/-)), showed significantly reduced transepithelial Ca(2+) transport (26 % of control), for the first time directly confirming the key role of TRPV5. Most importantly, using this cell model, a novel molecular player in transepithelial Ca(2+) transport was identified: mRNA analysis revealed that ATP-dependent Ca(2+)-ATPase 4 (PMCA4) instead of PMCA1 was enriched in isolated tubules and downregulated in TRPV5(-/-) material. Immunohistochemical stainings confirmed co-localization of PMCA4 with TRPV5 in the distal convolution. In conclusion, a novel primary cell model with TRPV5-dependent Ca(2+) transport characteristics was successfully established, enabling comprehensive studies of transcellular Ca(2+) transport.


Asunto(s)
Canales de Calcio/metabolismo , Calcio/metabolismo , Túbulos Renales Distales/metabolismo , Transporte de Proteínas/fisiología , Canales Catiónicos TRPV/metabolismo , Adenosina Trifosfato/metabolismo , Animales , ATPasas Transportadoras de Calcio/metabolismo , Ratones , Hormona Paratiroidea/metabolismo , ATPasas Transportadoras de Calcio de la Membrana Plasmática/metabolismo , Vitamina D/análogos & derivados , Vitamina D/metabolismo
12.
J Biol Chem ; 286(37): 32132-9, 2011 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-21795703

RESUMEN

The epithelial Ca(2+) channel transient receptor potential vanilloid 5 (TRPV5) constitutes the apical entry site for active Ca(2+) reabsorption in the kidney. The TRPV5 channel is a member of the TRP family of cation channels, which are composed of four subunits together forming a central pore. Regulation of channel activity is tightly controlled by the intracellular N and C termini. The TRPV5 C terminus regulates channel activity by various mechanisms, but knowledge regarding the role of the N terminus remains scarce. To study the role of the N terminus in TRPV5 regulation, we generated different N-terminal deletion constructs. We found that deletion of the first 32 residues did not affect TRPV5-mediated (45)Ca(2+) uptake, whereas deletion up to residue 34 and 75 abolished channel function. Immunocytochemistry demonstrated that these mutant channels were retained in the endoplasmic reticulum and in contrast to wild-type TRPV5 did not reach the Golgi apparatus, explaining the lack of complex glycosylation of the mutants. A limited amount of mutant channels escaped the endoplasmic reticulum and reached the plasma membrane, as shown by cell surface biotinylation. These channels did not internalize, explaining the reduced but significant amount of these mutant channels at the plasma membrane. Wild-type TRPV5 channels, despite significant plasma membrane internalization, showed higher plasma membrane levels compared with the mutant channels. The assembly into tetramers was not affected by the N-terminal deletions. Thus, the N-terminal residues 34-75 are critical in the formation of a functional TRPV5 channel because the deletion mutants were present at the plasma membrane as tetramers, but lacked channel activity.


Asunto(s)
Calcio/metabolismo , Membrana Celular/metabolismo , Aparato de Golgi/metabolismo , Multimerización de Proteína/fisiología , Canales Catiónicos TRPV/metabolismo , Secuencia de Aminoácidos , Animales , Membrana Celular/genética , Aparato de Golgi/genética , Células HEK293 , Humanos , Estructura Terciaria de Proteína , Transporte de Proteínas/fisiología , Conejos , Eliminación de Secuencia , Canales Catiónicos TRPV/genética
15.
Nephron ; 131(2): 145-52, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26418956

RESUMEN

BACKGROUND/AIMS: Fine-tuning of renal calcium (Ca(2+)) reabsorption takes place in the late distal convoluted and connecting tubules (DCT2/CNT) of the kidney via transcellular Ca(2+) transport. Here, Ca(2+) enters the cell at the apical side via the epithelial Ca(2+) channel transient receptor potential vanilloid 5 and is subsequently extruded at the basolateral side by the concerted actions of the plasma membrane Ca(2+) ATPases and the Na(+)/Ca(2+) exchanger 1 (NCX1). NCX1 is responsible for ∼ 70% of basolateral Ca(2+) extrusion. The aim of this study was to determine the predominant NCX1 variant in the kidney and its role in Ca(2+) transport. METHODS: DCT2/CNT specific tubules were used to show the abundance of NCX1 specific isoforms. Renal NCX1 variants were cloned from mouse kidney tissue. Human Embryonic Kidney 293(T) cells were transiently transfected with NCX1.3, and Fura-2 measurements and 45Ca(2+) uptake assays were performed to determine several characteristics of NCX1.3 in the reverse mode. RESULTS: NCX1.3 was demonstrated to be the predominant NCX1 variant in the DCT2/CNT, next to NCX1.2 and NCX1.7. NCX1.3 could be inhibited by SN-6, an NCX-specific inhibitor, whereas stimulation of the cAMP/PKA or PKC-mediated pathway did not affect Ca(2+) influx as measured in the reverse mode. Lowering intracellular Ca(2+) concentrations resulted in a decreased Ca(2+) uptake. CONCLUSION: NCX1.3 is the predominant NCX variant in the DCT2/CNT tubules. Its function is dependent on intracellular Ca(2+) concentrations.


Asunto(s)
Calcio/metabolismo , Túbulos Renales Distales/metabolismo , Intercambiador de Sodio-Calcio/metabolismo , Animales , Proteínas Quinasas Dependientes de AMP Cíclico/genética , Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , Epitelio/metabolismo , Exones , Variación Genética , Células HEK293 , Humanos , Isoenzimas/genética , Isoenzimas/metabolismo , Riñón/metabolismo , Ratones , Ratones Transgénicos , Fosforilación , Proteína Quinasa C/genética , Proteína Quinasa C/metabolismo , Intercambiador de Sodio-Calcio/antagonistas & inhibidores , Transfección
16.
Mol Cell Biol ; 31(14): 2845-53, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21576356

RESUMEN

The epithelial Ca(2+) channel transient receptor potential vanilloid 5 (TRPV5) constitutes the apical entry gate for active Ca(2+) reabsorption in the kidney. Ca(2+) influx through TRPV5 induces rapid channel inactivation, preventing excessive Ca(2+) influx. This inactivation is mediated by the last ∼30 residues of the carboxy (C) terminus of the channel. Since the Ca(2+)-sensing protein calmodulin has been implicated in Ca(2+)-dependent regulation of several TRP channels, the potential role of calmodulin in TRPV5 function was investigated. High-resolution nuclear magnetic resonance (NMR) spectroscopy revealed a Ca(2+)-dependent interaction between calmodulin and a C-terminal fragment of TRPV5 (residues 696 to 729) in which one calmodulin binds two TRPV5 C termini. The TRPV5 residues involved in calmodulin binding were mutated to study the functional consequence of releasing calmodulin from the C terminus. The point mutants TRPV5-W702A and TRPV5-R706E, lacking calmodulin binding, displayed a strongly diminished Ca(2+)-dependent inactivation compared to wild-type TRPV5, as demonstrated by patch clamp analysis. Finally, parathyroid hormone (PTH) induced protein kinase A (PKA)-dependent phosphorylation of residue T709, which diminished calmodulin binding to TRPV5 and thereby enhanced channel open probability. The TRPV5-W702A mutant exhibited a significantly increased channel open probability and was not further stimulated by PTH. Thus, calmodulin negatively modulates TRPV5 activity, which is reversed by PTH-mediated channel phosphorylation.


Asunto(s)
Calmodulina/metabolismo , Hormona Paratiroidea/metabolismo , Canales Catiónicos TRPV/metabolismo , Secuencia de Aminoácidos , Calcio/metabolismo , Colorantes Fluorescentes/metabolismo , Fura-2/análogos & derivados , Fura-2/metabolismo , Células HEK293 , Humanos , Datos de Secuencia Molecular , Resonancia Magnética Nuclear Biomolecular , Mutación Puntual , Unión Proteica , Canales Catiónicos TRPV/genética
SELECCIÓN DE REFERENCIAS