Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clin Immunol ; 257: 109817, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37925120

RESUMEN

A subset of autoimmune diseases is characterized by predominant pathogenic IgG4 autoantibodies (IgG4-AID). Why IgG4 predominates in these disorders is unknown. We hypothesized that dysregulated B cell maturation or aberrant class switching causes overrepresentation of IgG4+ B cells and plasma cells. Therefore, we compared the B cell compartment of patients from four different IgG4-AID with two IgG1-3-AID and healthy donors, using flow cytometry. Relative subset abundance at all maturation stages was normal, except for a, possibly treatment-related, reduction in immature and naïve CD5+ cells. IgG4+ B cell and plasma cell numbers were normal in IgG4-AID patients, however they had a (sub)class-independent 8-fold increase in circulating CD20-CD138+ cells. No autoreactivity was found in this subset. These results argue against aberrant B cell development and rather suggest the autoantibody subclass predominance to be antigen-driven. The similarities between IgG4-AID suggest that, despite displaying variable clinical phenotypes, they share a similar underlying immune profile.


Asunto(s)
Autoanticuerpos , Enfermedades Autoinmunes , Humanos , Cambio de Clase de Inmunoglobulina , Inmunoglobulina G , Linfocitos B
2.
Blood ; 138(24): 2539-2554, 2021 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-34314480

RESUMEN

Sézary syndrome (SS) is an aggressive leukemic form of cutaneous T-cell lymphoma with neoplastic CD4+ T cells present in skin, lymph nodes, and blood. Despite advances in therapy, prognosis remains poor, with a 5-year overall survival of 30%. The immunophenotype of Sézary cells is diverse, which hampers efficient diagnosis, sensitive disease monitoring, and accurate assessment of treatment response. Comprehensive immunophenotypic profiling of Sézary cells with an in-depth analysis of maturation and functional subsets has not been performed thus far. We immunophenotypically profiled 24 patients with SS using standardized and sensitive EuroFlow-based multiparameter flow cytometry. We accurately identified and quantified Sézary cells in blood and performed an in-depth assessment of their phenotypic characteristics in comparison with their normal counterparts in the blood CD4+ T-cell compartment. We observed inter- and intrapatient heterogeneity and phenotypic changes over time. Sézary cells exhibited phenotypes corresponding with classical and nonclassical T helper subsets with different maturation phenotypes. We combined multiparameter flow cytometry analyses with fluorescence-activated cell sorting and performed RNA sequencing studies on purified subsets of malignant Sézary cells and normal CD4+ T cells of the same patients. We confirmed pure monoclonality in Sézary subsets, compared transcriptomes of phenotypically distinct Sézary subsets, and identified novel downregulated genes, most remarkably THEMIS and LAIR1, which discriminate Sézary cells from normal residual CD4+ T cells. Together, these findings further unravel the heterogeneity of Sézary cell subpopulations within and between patients. These new data will support improved blood staging and more accurate disease monitoring.


Asunto(s)
Síndrome de Sézary/diagnóstico , Neoplasias Cutáneas/diagnóstico , Anciano , Anciano de 80 o más Años , Antígenos CD/análisis , Femenino , Citometría de Flujo , Humanos , Inmunofenotipificación , Linfocitos/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Síndrome de Sézary/patología , Neoplasias Cutáneas/patología
3.
Blood ; 129(3): 347-357, 2017 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-27903527

RESUMEN

A fully-standardized EuroFlow 8-color antibody panel and laboratory procedure was stepwise designed to measure minimal residual disease (MRD) in B-cell precursor (BCP) acute lymphoblastic leukemia (ALL) patients with a sensitivity of ≤10-5, comparable to real-time quantitative polymerase chain reaction (RQ-PCR)-based MRD detection via antigen-receptor rearrangements. Leukocyte markers and the corresponding antibodies and fluorochromes were selected based on their contribution in separating BCP-ALL cells from normal/regenerating BCP cells in multidimensional principal component analyses. After 5 multicenter design-test-evaluate-redesign phases with a total of 319 BCP-ALL patients at diagnosis, two 8-color antibody tubes were selected, which allowed separation between normal and malignant BCP cells in 99% of studied patients. These 2 tubes were tested with a new erythrocyte bulk-lysis protocol allowing acquisition of high cell numbers in 377 bone marrow follow-up samples of 178 BCP-ALL patients. Comparison with RQ-PCR-based MRD data showed a clear positive relation between the percentage concordant cases and the number of cells acquired. For those samples with >4 million cells acquired, concordant results were obtained in 93% of samples. Most discordances were clarified upon high-throughput sequencing of antigen-receptor rearrangements and blind multicenter reanalysis of flow cytometric data, resulting in an unprecedented concordance of 98% (97% for samples with MRD < 0.01%). In conclusion, the fully standardized EuroFlow BCP-ALL MRD strategy is applicable in >98% of patients with sensitivities at least similar to RQ-PCR (≤10-5), if sufficient cells (>4 × 106, preferably more) are evaluated.


Asunto(s)
Citometría de Flujo/métodos , Neoplasia Residual/diagnóstico , Leucemia-Linfoma Linfoblástico de Células Precursoras B/diagnóstico , Adolescente , Adulto , Anciano , Niño , Preescolar , Femenino , Citometría de Flujo/normas , Reordenamiento Génico , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Reacción en Cadena en Tiempo Real de la Polimerasa , Receptores de Antígenos de Linfocitos B/genética , Sensibilidad y Especificidad , Adulto Joven
4.
Cytometry A ; 87(2): 145-56, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25345353

RESUMEN

Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry.


Asunto(s)
Citometría de Flujo/métodos , Inmunofenotipificación/métodos , Leucemia/diagnóstico , Subgrupos Linfocitarios/inmunología , Linfoma/diagnóstico , Europa (Continente) , Voluntarios Sanos , Leucemia/clasificación , Linfoma/clasificación , Control de Calidad , Estándares de Referencia , Valores de Referencia
5.
Br J Haematol ; 161(6): 861-4, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23577982

RESUMEN

B-cell precursors (BCP) regeneration in bone marrow (BM) after induction chemotherapy is prognostic for good treatment response in adult acute myeloid leukaemia (AML). We detected BCP regeneration in 81% of 59 paediatric AML patients at first complete remission; this compared to 46% in an adult study. BCP regeneration did not correlate with outcome or minimal residual disease levels. In 36 healthy BM controls, BCP levels were significantly higher in children as compared to adults. Therefore, BCP regeneration does not reflect good response to treatment in paediatric AML, possibly due to the relatively high base-line levels of BCP in children.


Asunto(s)
Leucemia Mieloide Aguda/metabolismo , Células Precursoras de Linfocitos B/metabolismo , Adolescente , Adulto , Anciano , Células de la Médula Ósea/metabolismo , Estudios de Casos y Controles , Niño , Preescolar , Humanos , Inmunofenotipificación , Quimioterapia de Inducción , Lactante , Leucemia Mieloide Aguda/diagnóstico , Leucemia Mieloide Aguda/tratamiento farmacológico , Persona de Mediana Edad , Fenotipo , Pronóstico , Recurrencia , Resultado del Tratamiento , Adulto Joven
6.
Cancers (Basel) ; 14(8)2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-35454917

RESUMEN

Flowcytometric analysis allows for detailed identification and characterization of large numbers of cells in blood, bone marrow, and other body fluids and tissue samples and therefore contributes to the diagnostics of hematological malignancies. Novel data analysis tools allow for multidimensional analysis and comparison of patient samples with reference databases of normal, reactive, and/or leukemia/lymphoma patient samples. Building such reference databases requires strict quality assessment (QA) procedures. Here, we compiled a dataset and developed a QA methodology of the EuroFlow Acute Myeloid Leukemia (AML) database, based on the eight-color EuroFlow AML panel consisting of six different antibody combinations, including four backbone markers. In total, 1142 AML cases and 42 normal bone marrow samples were included in this analysis. QA was performed on 803 AML cases using multidimensional analysis of backbone markers, as well as tube-specific markers, and data were compared using classical analysis employing median and peak expression values. Validation of the QA procedure was performed by re-analysis of >300 cases and by running an independent cohort of 339 AML cases. Initial evaluation of the final cohort confirmed specific immunophenotypic patterns in AML subgroups; the dataset therefore can reliably be used for more detailed exploration of the immunophenotypic variability of AML. Our data show the potential pitfalls and provide possible solutions for constructing large flowcytometric databases. In addition, the provided approach may facilitate the building of other databases and thereby support the development of novel tools for (semi)automated QA and subsequent data analysis.

7.
Front Immunol ; 13: 935879, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36189252

RESUMEN

Innate myeloid cell (IMC) populations form an essential part of innate immunity. Flow cytometric (FCM) monitoring of IMCs in peripheral blood (PB) has great clinical potential for disease monitoring due to their role in maintenance of tissue homeostasis and ability to sense micro-environmental changes, such as inflammatory processes and tissue damage. However, the lack of standardized and validated approaches has hampered broad clinical implementation. For accurate identification and separation of IMC populations, 62 antibodies against 44 different proteins were evaluated. In multiple rounds of EuroFlow-based design-testing-evaluation-redesign, finally 16 antibodies were selected for their non-redundancy and separation power. Accordingly, two antibody combinations were designed for fast, sensitive, and reproducible FCM monitoring of IMC populations in PB in clinical settings (11-color; 13 antibodies) and translational research (14-color; 16 antibodies). Performance of pre-analytical and analytical variables among different instruments, together with optimized post-analytical data analysis and reference values were assessed. Overall, 265 blood samples were used for design and validation of the antibody combinations and in vitro functional assays, as well as for assessing the impact of sample preparation procedures and conditions. The two (11- and 14-color) antibody combinations allowed for robust and sensitive detection of 19 and 23 IMC populations, respectively. Highly reproducible identification and enumeration of IMC populations was achieved, independently of anticoagulant, type of FCM instrument and center, particularly when database/software-guided automated (vs. manual "expert-based") gating was used. Whereas no significant changes were observed in identification of IMC populations for up to 24h delayed sample processing, a significant impact was observed in their absolute counts after >12h delay. Therefore, accurate identification and quantitation of IMC populations requires sample processing on the same day. Significantly different counts were observed in PB for multiple IMC populations according to age and sex. Consequently, PB samples from 116 healthy donors (8-69 years) were used for collecting age and sex related reference values for all IMC populations. In summary, the two antibody combinations and FCM approach allow for rapid, standardized, automated and reproducible identification of 19 and 23 IMC populations in PB, suited for monitoring of innate immune responses in clinical and translational research settings.


Asunto(s)
Anticuerpos , Células Mieloides , Anticoagulantes , Citometría de Flujo , Humanos , Inmunofenotipificación , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA