Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Cardiovasc Disord ; 20(1): 148, 2020 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-32204693

RESUMEN

BACKGROUND: Where each patient has all three conduits of internal mammary artery (IMA), saphenous vein graft (SVG) and radial artery (RA), most confounders affecting comparison between conduits can be mitigated. Additionally, since SVG progressively fails over time, restricting patient angiography to the late period only can mitigate against early SVG patency that may have occluded in the late period. METHODS: Research protocol driven conventional angiography was performed for patients with at least one of each conduit of IMA, RA and SVG and a minimum of 7 years postoperative. The primary analysis was perfect patency and secondary analysis was overall patency including angiographic evidence of conduit lumen irregularity from conduit atheroma. Multivariable generalized linear mixed model (GLMM) was used. Patency excluded occluded or "string sign" conduits. Perfect patency was present in patent grafts if there was no lumen irregularity. RESULTS: Fifty patients underwent coronary angiography at overall duration postoperative 13.1 ± 2.9, and age 74.3 ± 7.0 years. Of 196 anastomoses, IMA 62, RA 77 and SVG 57. Most IMA were to the left anterior descending territory and most RA and SVG were to the circumflex and right coronary territories. Perfect patency RA 92.2% was not different to IMA 96.8%, P = 0.309; and both were significantly better than SVG 17.5%, P < 0.001. Patency RA 93.5% was also not different to IMA 96.8%, P = 0.169, and both arterial conduits were significantly higher than SVG 82.5%, P = 0.029. Grafting according to coronary territory was not significant for perfect patency, P = 0.997 and patency P = 0.289. Coronary stenosis predicted perfect patency for RA only, P = 0.030 and for patency, RA, P = 0.007, and SVG, P = 0.032. When both arterial conduits were combined, perfect patency, P < 0.001, and patency, P = 0.017, were superior to SVG. CONCLUSIONS: All but one patent internal mammary artery or radial artery grafts had perfect patency and had superior perfect patency and overall patency compared to saphenous vein grafts.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Arterias Mamarias/cirugía , Arteria Radial/trasplante , Vena Safena/trasplante , Grado de Desobstrucción Vascular , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Arterias Mamarias/diagnóstico por imagen , Arterias Mamarias/fisiopatología , Persona de Mediana Edad , Estudios Prospectivos , Arteria Radial/diagnóstico por imagen , Arteria Radial/fisiopatología , Factores de Riesgo , Vena Safena/diagnóstico por imagen , Vena Safena/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA