Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Neurosurg Rev ; 47(1): 605, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39269622

RESUMEN

BACKGROUND: The neurovascular conflict (NVC) at the brainstem exit zone of the facial nerve is considered the primary etiology of primary hemifacial spasm (HFS). Therefore, microvascular decompression (MVD) has become the preferred treatment for HFS. Successful neurovascular decompression can achieve significant therapeutic effects, and accurately identifying the site of compression is crucial for the success of this surgery. Detailed diagnostic neuroimaging plays an important role in accurately identifying the site of compression.The purpose of this study is to explore the feasibility and predictive value of preoperative visualization assessment of the neurovascular relationship in HFS using 3D Slicer software based on multimodal imaging fusion. This aims to reduce the omission of responsible vessels and lower the incidence of postoperative complications, thereby potentially improving the efficacy and safety of the surgery. METHODS: This study retrospectively analyzed 80 patients with HFS who underwent MVD surgery. All patients underwent preoperative cranial MRI scans, including the 3D-FIESTA and the 3D-TOF MRA sequences. Three-dimensional models were reconstructed from the multimodal MRI images using 3D Slicer software. Independent observers, who were blinded to the surgical outcomes, evaluated the neurovascular relationships using both the three-dimensional models and multimodal MRI images. The assessment results were compared with intraoperative findings, and statistical analysis was conducted using SPSS 22.0 software. RESULTS: The agreement between preoperative assessment using the 3D-TOF MRA sequence combined with the 3D-FIESTA sequence and intraoperative findings was represented by a Kappa value of 0.343, while the Kappa value for agreement between three-dimensional reconstruction and intraoperative findings was 0.637. There was a statistically significant difference between the two methods ( X2 = 18.852, P = 0.001 ). The sensitivity and specificity of the 3D-TOF MRA sequence combined with the 3D-FIESTA sequence for evaluating neurovascular relationships were 92.4% and 100%, respectively, while for three-dimensional reconstruction, both were 100%. The Kappa value for agreement between preoperative the 3D-TOF MRA sequence combined with the 3D-FIESTA sequence prediction of offending vessels and intraoperative findings was 0.625, while the Kappa value for agreement between three-dimensional reconstruction and intraoperative findings was 0.938, showing a statistically significant difference ( X2 = 317.798, P = 0.000 ). The Kappa value for agreement between preoperative the 3D-TOF MRA sequence combined with the 3D-FIESTA sequence assessment of the anatomical location of facial nerve involvement in neurovascular compression and intraoperative findings was 0.608, while the Kappa value for agreement between three-dimensional reconstruction and intraoperative findings was 0.918, also showing a statistically significant difference ( X2 = 504.647, P = 0.000 ). CONCLUSIONS: The preoperative visualization assessment of neurovascular relationships in HFS using 3D Slicer software based on multimodal imaging fusion has been demonstrated to be reliable. It is more accurate than combining the 3D-TOF MRA sequence with the 3D-FIESTA sequence and shows higher consistency with intraoperative findings. This method provides guidance for surgical procedures and thereby potentially enhances the efficacy and safety of surgeries to a certain extent.


Asunto(s)
Espasmo Hemifacial , Imagen por Resonancia Magnética , Cirugía para Descompresión Microvascular , Imagen Multimodal , Humanos , Espasmo Hemifacial/cirugía , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Cirugía para Descompresión Microvascular/métodos , Adulto , Imagen Multimodal/métodos , Anciano , Imagen por Resonancia Magnética/métodos , Nervio Facial/cirugía , Nervio Facial/diagnóstico por imagen , Cuidados Preoperatorios/métodos , Resultado del Tratamiento , Imagenología Tridimensional/métodos
2.
Sensors (Basel) ; 24(4)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38400229

RESUMEN

The multimodal and multidomain registration of medical images have gained increasing recognition in clinical practice as a powerful tool for fusing and leveraging useful information from different imaging techniques and in different medical fields such as cardiology and orthopedics. Image registration could be a challenging process, and it strongly depends on the correct tuning of registration parameters. In this paper, the robustness and accuracy of a landmarks-based approach have been presented for five cardiac multimodal image datasets. The study is based on 3D Slicer software and it is focused on the registration of a computed tomography (CT) and 3D ultrasound time-series of post-operative mitral valve repair. The accuracy of the method, as a function of the number of landmarks used, was performed by analysing root mean square error (RMSE) and fiducial registration error (FRE) metrics. The validation of the number of landmarks resulted in an optimal number of 10 landmarks. The mean RMSE and FRE values were 5.26 ± 3.17 and 2.98 ± 1.68 mm, respectively, showing comparable performances with respect to the literature. The developed registration process was also tested on a CT orthopaedic dataset to assess the possibility of reconstructing the damaged jaw portion for a pre-operative planning setting. Overall, the proposed work shows how 3D Slicer and registration by landmarks can provide a useful environment for multimodal/unimodal registration.


Asunto(s)
Ortopedia , Tomografía Computarizada por Rayos X/métodos , Pulmón , Programas Informáticos , Corazón , Imagenología Tridimensional/métodos , Algoritmos
3.
Neurosurg Rev ; 46(1): 210, 2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37639047

RESUMEN

The purpose of this study is to explore the evolution of brain edema after minimally invasive surgery in deep spontaneous cerebral hemorrhage (DSICH) treatment and to analyze the differences in edema after different surgical methods. The clinical data of 105 patients with DSICH treated at Renmin Hospital of Wuhan University from January 2020 to June 2022 were analyzed retrospectively. Among them, 54 patients were treated with minimally invasive puncture and drainage surgery (MIPDS group), and 51 were treated with neuroendoscopic surgery (NES group). Continuous computed tomography images of patients in the hospital and 3D Slicer software were used to quantitatively calculate the edematous area to explore the changes in perihematomal edema volume in the two groups after the operation. The peak volume of postoperative edema (37.36±10.51 mL) in the MIPDS group was more extensive than that in the NES group, and its net increase in edema volume was 16.86±10.01 mL more than that in the NES group. The relative edema index (0.86±0.26) was lower in the NES group than in the MIPDS group (P < 0.05). The peak of postoperative edema in the MIPDS group was at 6-8 days after the operation, and that in the NES group was most often at 3-5 days after the operation. There are differences in perihematomal edema of DSICH treated by different minimally invasive methods. Compared with the MIPDS group, the NES group showed earlier peak of cerebral edema and lower degree of cerebral edema. The absolute regression volume of edema in the MIDPs group was greater than that in the NEs group, but there was no difference in the regression rate of edema between the two groups.


Asunto(s)
Edema Encefálico , Humanos , Edema Encefálico/etiología , Neurocirujanos , Estudios Retrospectivos , Edema/etiología , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Hemorragia Cerebral
4.
J Med Syst ; 47(1): 62, 2023 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-37171621

RESUMEN

We aimed to assess the feasibility of developing three-dimensional (3D) models of pelvic organs using cross-sectional MRI images of patients with uterine fibroids and urinary symptoms and of obtaining anatomical information unavailable in 2D imaging modalities. We also aimed to compare two image processing applications. We performed a feasibility study analysing MRI scans from three women, aged 30 to 58 years old, with fibroids and urinary symptoms. Cross-sectional images were used to render 3D models of pelvic anatomy, including bladder, uterus and fibroids, using 3D Slicer and OsiriX. Dimensions, volumes and anatomical relationships of the pelvic organs were evaluated. Comparisons between anatomical landmarks and measurements obtained from the two image processing applications were undertaken. Rendered 3D pelvic models yielded detailed anatomical information and data on spatial relationships that were unobtainable from cross-sectional images. Models were rendered in sufficient resolution to aid understanding of spatial relationships between urinary bladder, uterus and fibroid(s). Measurements of fibroid volumes ranged from 5,336 to 418,012 mm3 and distances between the fibroid and urinary bladder ranged from 0.10 to 83.60 mm. Statistical analysis of measurements showed no significant differences in measurements between the two image processing applications. To date, limited data exist on the use of 3D volume reconstructions of routine MRI scans, to investigate pelvic pathologies such as fibroids in women with urinary symptoms. This study suggests that post-MRI image processing can provide additional information over standard MRI. Further studies are required to assess the role of these data in clinical practice, surgical planning and training. Three-dimensional reconstruction of routine two-dimensional magnetic resonance imaging provides additional anatomical information and may improve our understanding of anatomical relationships, their role in clinical presentations and possibly guide clinical and surgical management.


Asunto(s)
Leiomioma , Diafragma Pélvico , Humanos , Femenino , Adulto , Persona de Mediana Edad , Leiomioma/diagnóstico por imagen , Leiomioma/patología , Imagen por Resonancia Magnética/métodos , Útero , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional/métodos
5.
BMC Neurol ; 22(1): 452, 2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-36471307

RESUMEN

BACKGROUND: Irregular hematoma is considered as a risk sign of hematoma expansion. The aim of this study was to quantify hematoma irregularity with computed tomography based on 3D Slicer. METHODS: Patients with spontaneous intracerebral hemorrhage who underwent an initial and subsequent non-contrast computed tomography (CT) at a single medical center between January 2019 to January 2020 were retrospectively identified. The Digital Imaging and Communication in Medicine (DICOM) standard images were loaded into the 3D Slicer, and the surface area (S) and volume (V) of hematoma were calculated. The hematoma irregularity index (HII) was defined as [Formula: see text]. Logistic regression analyses and receiver operating characteristic (ROC) curve analysis were performed to assess predictive performance of HII. RESULTS: The enrolled patients were divided into those with hematoma enlargement (n = 36) and those without the enlargement (n = 57). HII in hematoma expansion group was 130.4 (125.1-140.0), and the index in non-enlarged hematoma group was 118.6 (113.5-122.3). There was significant difference in HII between the two groups (P < 0.01). Multivariate logistic regression analysis revealed that the HII was significantly associated with hematoma expansion before (odds ratio = 1.203, 95% confidence interval [CI], 1.115-1.298; P < 0.001) and after adjustment for age, hematoma volume, Glasgow Coma Scale score (odds ratio = 1.196, 95% CI, 1.102-1.298, P < 0.001). The area under the ROC curve was 0.86 (CI, 0.78-0.93, P < 0.01), and the best cutoff of HII for predicting hematoma growth was 123.8. CONCLUSION: As a quantitative indicator of irregular hematoma, HII can be calculated using the 3D Slicer. And the HII was independently correlated with hematoma expansion.


Asunto(s)
Hemorragia Cerebral , Hematoma , Humanos , Estudios Retrospectivos , Hematoma/diagnóstico por imagen , Hematoma/complicaciones , Hemorragia Cerebral/complicaciones , Curva ROC , Escala de Coma de Glasgow
6.
Eur Arch Otorhinolaryngol ; 279(12): 5631-5638, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35727414

RESUMEN

PURPOSE: During cochlear implantation surgery, a range of complications may occur such as tip fold-over. We recently developed a method to estimate the insertion orientation of the electrode array. The aim of the study was to determine the optimal angle of orientation in a cohort of cochlear implanted patients. METHODS: On eighty-five CT scans (80 uncomplicated insertions and 5 cases with tip fold-over), location of the electrode array's Insertion Guide (IG), Orientation marker (OM) and two easily identifiable landmarks (the round window (RW) and the incus short process (ISP)) were manually marked. The angle enclosed by ISP-RW line and the Cochlear™ Slim Modiolar electrode array's OM line determined the electrode array insertion angle. RESULTS: The average insertion angle was 45.0-47.2° ± 10.4-12° SD and was validated with 98% confidence interval. Based on the measurements obtained, patients' sex and age had no impact on the size of this angle. Although the angles of the tip fold-over cases (44.9°, 46.9°, 34.2°, 54.3°, 55.9°) fell within this average range, the further it diverted from the average it increased the likelihood for tip fold-over. CONCLUSION: Electrode array insertion in the individually calculated angle relative to the visible incus short process provides a useful guide for the surgeon when aiming for the optimal angle, and potentially enhances good surgical outcomes. Our results show that factors other than the orientation angle may additionally contribute to failures in implantation when the Slim Modiolar electrode is used.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Ventana Redonda/cirugía , Cóclea/cirugía , Electrodos Implantados
7.
Tech Coloproctol ; 26(9): 735-743, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35676544

RESUMEN

BACKGROUND: We carried out robot-assisted lateral pelvic lymph node dissection (LPLND) for rectal cancer with a stereotactic navigation system. The purpose of this study was to evaluate the accuracy and feasibility of the system. METHODS: We constructed a navigation system based on the Polaris Spectra optical tracking device (Northern Digital Inc., Canada) and the open-source software 3D Slicer (version 3.8.1; http://www.slicer.org ). We used the landmark-based registration method for patient-to-image registration. Body surface landmarks and intra-abdominal landmarks were used. We evaluated the time required for registration and target registration error (TRE; the distance between corresponding points after registration) for the root of the superior gluteal artery the root of the obturator or superior vesical artery, and the obturator foramen during minimally invasive LPLND for rectal cancer. Five patients who had LPLND for rectal cancer at the University of Tokyo Hospital between September 2020 and May 2021 were enrolled. RESULTS: The mean time required for registration was 49 s with the body surface landmarks and 88 s with the intra-abdominal landmarks. The mean TRE improved markedly when the registration was performed using intra-abdominal landmarks. The mean TRE of the root of the superior gluteal artery, the root of the obturator or superior vesical artery, and the obturator foramen were 55.8 mm, 53.4 mm, and 55.2 mm with the body surface landmarks and 11.8 mm, 10.0 mm, and 12.6 mm with the intra-abdominal landmarks, respectively. There were no adverse events related to the registration process. CONCLUSIONS: When stereotactic navigation systems are used for minimally invasive LPLND, the use of intra-abdominal landmarks for registration is feasible and may allow simpler and more accurate navigation than the use of body surface landmarks.


Asunto(s)
Neoplasias del Recto , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Humanos , Imagenología Tridimensional , Escisión del Ganglio Linfático/métodos , Pelvis/patología , Pelvis/cirugía , Neoplasias del Recto/cirugía , Cirugía Asistida por Computador/métodos
8.
Sensors (Basel) ; 22(14)2022 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-35891016

RESUMEN

Developing image-guided robotic systems requires access to flexible, open-source software. For image guidance, the open-source medical imaging platform 3D Slicer is one of the most adopted tools that can be used for research and prototyping. Similarly, for robotics, the open-source middleware suite robot operating system (ROS) is the standard development framework. In the past, there have been several "ad hoc" attempts made to bridge both tools; however, they are all reliant on middleware and custom interfaces. Additionally, none of these attempts have been successful in bridging access to the full suite of tools provided by ROS or 3D Slicer. Therefore, in this paper, we present the SlicerROS2 module, which was designed for the direct use of ROS2 packages and libraries within 3D Slicer. The module was developed to enable real-time visualization of robots, accommodate different robot configurations, and facilitate data transfer in both directions (between ROS and Slicer). We demonstrate the system on multiple robots with different configurations, evaluate the system performance and discuss an image-guided robotic intervention that can be prototyped with this module. This module can serve as a starting point for clinical system development that reduces the need for custom interfaces and time-intensive platform setup.


Asunto(s)
Robótica , Diagnóstico por Imagen , Especies Reactivas de Oxígeno , Programas Informáticos
9.
J Digit Imaging ; 35(2): 356-364, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35064370

RESUMEN

We investigate the correlation between diffusion tensor imaging (DTI)-derived metric statistics and motor strength grade of insular glioma patients after optimizing the pyramidal tract (PT) delineation. Motor strength grades of 45 insular glioma patients were assessed. All the patients underwent structural and diffusion MRI examination before and after surgery. We co-registered pre- and post-op datasets, and a two-tensor unscented Kalman filter (UKF) algorithm was employed to delineate bilateral PTs after DWI pre-processing. The tractography results were voxelized, and their labelmaps were cropped according to the location of frontal and insular parts of the lesion. Both the whole and cropped labelmaps were used as regions of interest to analyze fractional anisotropy (FA) and Trace statistics; hence, their ratios were calculated (lesional side tract/contralateral normal tract). The combination of DWI pre-processing and two-tensor UKF algorithm successfully delineated bilateral PTs of all the patients. It effectively accomplished both full fiber delineation within the edema and an extensive lateral fanning that had a favorable correspondence to the bilateral motor cortices. Before surgery, correlations were found between patients' motor strength grades and ratios of PT volume and FA standard deviation (SD). Nearly 3 months after surgery, correlations were found between motor strength grades and the ratios of metric statistics as follows: whole PT volume, whole mean FA, and FA SD. We substantiated the correlation between DTI-derived metric statistics and motor strength grades of insular glioma patients. Moreover, we posed a workflow for comprehensive pre- and post-op DTI quantitative research of glioma patients.


Asunto(s)
Neoplasias Encefálicas , Glioma , Benchmarking , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/cirugía , Imagen de Difusión Tensora/métodos , Glioma/diagnóstico por imagen , Glioma/cirugía , Humanos , Tractos Piramidales/diagnóstico por imagen , Tractos Piramidales/patología
10.
J Surg Oncol ; 123(8): 1757-1763, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33684252

RESUMEN

BACKGROUND: This study evaluates the achievability of CT volumetry of pancreatic cancer and its correlation with pTNM stage and survival. METHODS: Tumor volume was measured from contrast enhanced CT images of 58 patients who undergo curative resection for pancreatic cancer using the Segment Editor module implemented in 3D-Slicer-a free open source software platform. Receiver operating characteristic (ROC) analysis was used to evaluate correlation between Tvol and pTNM staging. RESULTS: The preoperative images of 58 pancreatic adenocarcinoma patients were included. The mean Tvol of pancreatic cancer is an increasing trend with T stage (The mean T1vol = 1.75 cm3 , the mean T2vol = 11.43 cm3 , the mean T3vol = 14.98 cm3 , the mean T4vol = 19.6 cm3 ). There were statistical differences between volumes (p = .000). On ROC analysis, the area under the ROC curve (Az) of Tvol to differentiate T1 stage from ≥T2 stage was 0.966 (p = .000). At a cut-off value of 3.050 cm3 , sensitivity of 92.3%, and specificity of 83.3% were achieved. Az value of Tvol to differentiate ≤T2 from ≥T3 stage was 0.750 (p = .010). At a cut-off value of 10.250 cm3 , sensitivity of 72.7% and specificity of 66% were achieved. In addition Az value of Tvol to differentiate ≤T3 from ≥T4 stage was 0.652 and was not significant (p = .380). At a cut-off value of 11.2 cm3 , sensitivity of 66.7% and specificity of 63.6% were achieved. CONCLUSION: CT volumetry in pancreatic cancer is feasible with excellent reproducibility. It is one of the prognostic factors affecting survival in operated patients with pancreatic cancer.


Asunto(s)
Adenocarcinoma/diagnóstico , Adenocarcinoma/mortalidad , Tomografía Computarizada de Haz Cónico , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/mortalidad , Adenocarcinoma/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Pancreatectomía , Neoplasias Pancreáticas/cirugía , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tasa de Supervivencia
11.
J Digit Imaging ; 34(2): 362-366, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33846887

RESUMEN

Penetrating brain injury caused by a nail is an extremely rare neurosurgical emergency that poses a challenge for neurosurgeons. Nail entering the brain from the orbit and lodging within the cranial cavity is even more unusual. A 53-year-old male was found unconscious at a construction site, and brain CT revealed not only the presence of a nail beneath the inner table of the parietal bone, but also traumatic intracerebral hematoma. Consequently, accurate localization of the nail and hematoma was mandatory for surgical plan. During surgical planning, computational model reconstruction and trajectory calculation were completed using preoperative CT in 3D Slicer. Under the guidance of a head-mounted mixed-reality holographic computer, the neurosurgeon was able to visualize and interact with the hologram of the surgical plan, and intraoperative findings demonstrated that our low-cost portable wearable mixed-reality holographic navigation assisted precise localization of the nail and intracerebral hematoma, assuring less injury to the already compromised brain. After the surgery, the patient could obey commands, and postoperative imaging ruled out the possibility of brain abscess during follow-up. To the best of our knowledge, this is the first report on using a low-cost wearable mixed-reality holographic navigation to guide the management of penetrating intracranial injury caused by a nail.


Asunto(s)
Realidad Aumentada , Traumatismos Penetrantes de la Cabeza , Dispositivos Electrónicos Vestibles , Encéfalo , Traumatismos Penetrantes de la Cabeza/diagnóstico por imagen , Traumatismos Penetrantes de la Cabeza/cirugía , Humanos , Masculino , Persona de Mediana Edad
12.
J Med Syst ; 45(3): 27, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33469726

RESUMEN

The feasibility of rendering three dimensional (3D) pelvic models of vaginal, urethral and paraurethral lesions from 2D MRI has been demonstrated previously. To quantitatively compare 3D models using two different image processing applications: 3D Slicer and OsiriX. Secondary analysis and processing of five MRI scan based image sets from female patients aged 29-43 years old with vaginal or paraurethral lesions. Cross sectional image sets were used to create 3D models of the pelvic structures with 3D Slicer and OsiriX image processing applications. The linear dimensions of the models created using the two different methods were compared using Bland-Altman plots. The comparisons demonstrated good agreement between measurements from the two applications. The two data sets obtained from different image processing methods demonstrated good agreement. Both 3D Slicer and OsiriX can be used interchangeably and produce almost similar results. The clinical role of this investigation modality remains to be further evaluated.


Asunto(s)
Imagen por Resonancia Magnética , Pelvis , Abdomen , Estudios Transversales , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Pelvis/diagnóstico por imagen
13.
J Prosthodont ; 29(7): 604-610, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32495453

RESUMEN

PURPOSE: To evaluate the accuracy of implant placement position using two different dental implant planning software. MATERIALS AND METHODS: A set of Digital Imaging and Communications in Medicine (DICOM) files from a cone beam computed tomography of a patient missing maxillary right first premolar was used. Implant planning was done using two open-source programs: A nondental 3D Slicer/Blender (3DSB) software and a commercial dental implant treatment planning program: Blue Sky Plan 4 (BSP4). An intraoral scan of the same patient was used to create a standard tessellation language (STL) file of the maxillary arch and later printed into 20 identical casts. Ten surgical guides were printed for each group as well. A dental implant (3.8 mm × 12 mm, Biohorizons) was placed into each cast using fully guided surgical protocol. The horizontal displacements at the implant cervical platform and at the implant apex as well as the angulation displacements were measured using digital scanning of the implant scan bodies and were analyzed using a 3D compare software. Statistical analyses were conducted (⍺ = 0.05) using t-test and F-test to examine differences in trueness and precision, respectively. RESULTS: The average horizontal deviations for the platform and the apex, respectively, were 0.33 ± 0.12 mm and 0.76 ± 0.30 mm for 3DSB and 0.44 ± 0.21 mm and 0.98 ± 0.48 mm for BSP4. The average angulation deviations for 3DSB and BSB4 were 2.34 ± 0.93° and 3.07 ± 1.57°, respectively. There were no statistical differences in the means (t-test) of the platform, apex, and angulation deviations (p = 0.16, p = 0.19, and p = 0.18, respectively). There were statistical differences in the variances (F test) of the platform (p = 0.043) and angulation (p = 0.049) deviations but not the apex (p = 0.059) deviations. CONCLUSIONS: The combination of nondental open-source software, 3D Slicer/Blender can be used to plan implant guided surgery with an accuracy similar to commercial dental software with slightly higher precision. Open-source nondental software can be considered as an alternative in dental implant treatment planning and guided surgery.


Asunto(s)
Implantes Dentales , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Humanos , Imagenología Tridimensional , Programas Informáticos
14.
J Med Syst ; 42(3): 36, 2018 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-29333590

RESUMEN

Currently, there are sophisticated applications that make it possible to visualize medical images and even to manipulate them. These software applications are of great interest, both from a teaching and a radiological perspective. In addition, some of these applications are known as Free Open Source Software because they are free and the source code is freely available, and therefore it can be easily obtained even on personal computers. Two examples of free open source software are Osirix Lite® and 3D Slicer®. However, this last group of free applications have limitations in its use. For the radiological field, manipulating and post-processing images is increasingly important. Consequently, sophisticated computing tools that combine software and hardware to process medical images are needed. In radiology, graphic workstations allow their users to process, review, analyse, communicate and exchange multidimensional digital images acquired with different image-capturing radiological devices. These radiological devices are basically CT (Computerised Tomography), MRI (Magnetic Resonance Imaging), PET (Positron Emission Tomography), etc. Nevertheless, the programs included in these workstations have a high cost which always depends on the software provider and is always subject to its norms and requirements. With this study, we aim to present the advantages and disadvantages of these radiological image visualization systems in the advanced management of radiological studies. We will compare the features of the VITREA2® and AW VolumeShare 5® radiology workstation with free open source software applications like OsiriX® and 3D Slicer®, with examples from specific studies.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Diseño de Software , Tomografía Computarizada por Rayos X/métodos , Humanos
15.
Acta Neurochir (Wien) ; 158(11): 2195-2201, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27543280

RESUMEN

OBJECTIVE: To explore whether segmentation and 3D modeling are more accurate in the preoperative detection of the neurovascular relationship (NVR) in patients with trigeminal neuralgia (TN) compared to MRI fast imaging employing steady-state acquisition (FIESTA). METHOD: Segmentation and 3D modeling using 3D Slicer were conducted for 40 patients undergoing MRI FIESTA and microsurgical vascular decompression (MVD). The NVR, as well as the offending vessel determined by MRI FIESTA and 3D Slicer, was reviewed and compared with intraoperative manifestations using SPSS. RESULTS: The k agreement between the MRI FIESTA and operation in determining the NVR was 0.232 and that between the 3D modeling and operation was 0.6333. There was no significant difference between these two procedures (χ2 = 8.09, P = 0.088). The k agreement between the MRI FIESTA and operation in determining the offending vessel was 0.373, and that between the 3D modeling and operation was 0.922. There were significant differences between two of them (χ2 = 82.01, P = 0.000). The sensitivity and specificity for MRI FIESTA in determining the NVR were 87.2 % and 100 %, respectively, and for 3D modeling were both 100 %. CONCLUSION: The segmentation and 3D modeling were more accurate than MRI FIESTA in preoperative verification of the NVR and offending vessel. This was consistent with surgical manifestations and was more helpful for the preoperative decision and surgical plan.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Programas Informáticos , Neuralgia del Trigémino/diagnóstico por imagen , Adulto , Anciano , Descompresión Quirúrgica/métodos , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Neuralgia del Trigémino/cirugía
16.
J Med Syst ; 40(6): 154, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27147517

RESUMEN

We present a technological process based on the 3D Slicer software for the three-dimensional study of the brain's ventricular system with teaching purposes. It values the morphology of this complex brain structure, as a whole and in any spatial position, being able to compare it with pathological studies, where its anatomy visibly changes. 3D Slicer was also used to obtain volumetric measurements in order to provide a more comprehensive and detail representation of the ventricular system. We assess the potential this software has for processing high resolution images, taken from Magnetic Resonance and generate the three-dimensional reconstruction of ventricular system.


Asunto(s)
Ventrículos Cerebrales/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biología Computacional , Femenino , Humanos , Masculino , Persona de Mediana Edad , Programas Informáticos , Interfaz Usuario-Computador
17.
Clin Neurol Neurosurg ; 243: 108387, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38924844

RESUMEN

BACKGROUND: 3D-Slicer is an open-source medical image processing and visualization software. In the surgical treatment of trigeminal neuralgia, it is commonly used to predict the responsible vessels. However, there are few reports on the use of 3D-Slicer software to quantitatively measure the bilateral trigeminal nerve volume in patients with primary trigeminal neuralgia (PTN) based on the three-dimensional images. Therefore, this study aims to explore the role of three-dimensional fused images processed by 3D-Slicer in the evaluation of trigeminal nerve atrophy, providing an objective basis for the diagnosis of PTN. METHODS: 57 PTN patients who underwent microvascular decompression (MVD) or percutaneous balloon compression (PBC) surgery in Hebei general hospital between January 2020 and April 2023 were included. Additionally, 30 patients with facial spasms(HFS) were included as a control group. All patients underwent 3D-TOF-MRA and 3D-FIESTA sequence examinations. Comparisons of bilateral trigeminal nerve volumes within and between groups were conducted by performing image fusion using 3D-slicer. RESULTS: The volume of the affected trigeminal nerve in the MVD group (33.96 mm³±12.61 mm³) and PBC group (23.05 mm³±7.71 mm³) was smaller than that of the unaffected trigeminal nerve in the MVD group (39.61 mm³±12.83 mm³) and PBC group (26.14 mm³±6.42 mm³), as well as the average volume of the trigeminal nerve in the control group (40.27 mm³±10.25 mm³) (P<0.05). The differences in bilateral trigeminal ganglion volume (∆V) was significant between the MVD group (∆V=23.59 %±14.32 %) and the control group (∆V=14.64 %±10.00 %) (P<0.05). There was no statistical difference in the trigeminal nerve volume difference between the MVD group (∆V=23.59 %±14.32 %) and the PBC group (∆V=26.52 %±15.00 %) (P>0.05). CONCLUSION: Trigeminal nerve atrophy is correlated with primary trigeminal neuralgia. 3D-slicer software can quantitatively measure trigeminal nerve volume and assist in the diagnosis of primary trigeminal neuralgia based on the difference in bilateral trigeminal nerve volumes. However, trigeminal nerve atrophy is not associated with postoperative pain recurrence in patients.


Asunto(s)
Atrofia , Cirugía para Descompresión Microvascular , Imagen Multimodal , Nervio Trigémino , Neuralgia del Trigémino , Humanos , Neuralgia del Trigémino/cirugía , Neuralgia del Trigémino/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Nervio Trigémino/diagnóstico por imagen , Nervio Trigémino/patología , Nervio Trigémino/cirugía , Estudios Retrospectivos , Anciano , Atrofia/patología , Cirugía para Descompresión Microvascular/métodos , Imagen Multimodal/métodos , Adulto , Imagenología Tridimensional/métodos
18.
Front Neurosci ; 18: 1296019, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38352044

RESUMEN

This study aimed to explore a novel, non-segmented based on inverted water outline, and rapid 3D rendering method for identifying the responsible blood vessels for hemifacial spasm. First, the software was developed using the free and open-source 3D Slicer to process magnetic resonance images. Outlines of the water region were extracted and rendered in a three-dimensional space. The traditional image re-slicing technique (IMRT) was used for the control group, while non-segmented inverted water outline rendering (NSIWR) was used to observe the relevant blood vessels in the root entry/exit zone (REZ) of patients with hemifacial spasm. The intraoperative exploration results were considered the gold standard for comparing the differences in identifying relevant blood vessels between the two methods. Twenty-five patients were included, and the reconstruction effect evaluation suggested that NSIWR could effectively reconstruct the responsible blood vessels of the cochlea, facial nerve, and REZ. Compared with IMRT, NSIWR effectively improved the diagnosis of the responsible blood vessels in the REZ, clarified their sources and directions, and was consistent with intraoperative results. This study introduced a novel rapid rendering method based on NSIWR, which was successfully applied for hemifacial spasm. The method enhances accuracy in identifying responsible blood vessels in the REZ without needing multi-modal techniques. It has the potential to improve surgical effectiveness and reduce exploration time in treating hemifacial spasm.

19.
J Orthop Surg Res ; 19(1): 55, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38217013

RESUMEN

OBJECTIVE: To explore the applicability of bone reamer and trephine for foraminoscopy in percutaneous endoscopic lumbar discectomy (PELD), and to provide a theoretical basis for foraminoplasty options in clinical practice. METHODS: This study was a prospective cohort study. Sixty-three consecutive patients who underwent PELD for lumbar disc herniation between May 2021 and July 2022 were analysed. Foraminoplasty were performed by bone reamer or trephine. The amount of bone removed and the foramen area enlarged during foraminoplasty by both tools were measured by 3D slicer and Digimizer software, and the numbers of fluoroscopic views were recorded. RESULTS: The bone reamer removed less bone in the Superior Articular Process (SAP) than the trephine (t = 17.507, P < 0.001), and the area enlarged by the bone reamer was smaller than that of the trephine (t = 10.042, P = 0.002). The overall numbers of fluoroscopic views were significantly more in the bone reamer group than in the trephine group (t = 19.003, P < 0.001). In the bone reamer group, when the area of preoperative (FPZ) was no less than 54.55 mm2, the mean number of fluoroscopic views significantly decreased (t = 14.443, P = 0.001). CONCLUSION: Bone reamer was safer and trephine was more efficient for foraminoscopy in PELD. An area of preoperative (FPZ) of 54.55 mm2 can be used as a critical value: bone reamer reduced the risk for cases above the value, while trephine improved the efficiency for cases less than the value.


Asunto(s)
Discectomía Percutánea , Desplazamiento del Disco Intervertebral , Humanos , Desplazamiento del Disco Intervertebral/diagnóstico por imagen , Desplazamiento del Disco Intervertebral/cirugía , Resultado del Tratamiento , Estudios Prospectivos , Endoscopía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Estudios Retrospectivos
20.
Ann Nucl Med ; 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39179897

RESUMEN

AIM: CT images can identify structural and opacity alterations of the lungs while nuclear medicine's lung perfusion studies show the homogeneity (or lack of) of blood perfusion on the organ. Therefore, the use of SPECT/CT in lung perfusion scintigraphies can help physicians to assess anatomical and functional alterations of the lungs and to differentiate between acute and chronic disease. OBJECTIVE: To develop a computer-aided methodology to quantify the total global perfusion of the lungs via SPECT/CT images and to compare these results with parenchymal alterations obtained in CT images. METHODS: 39 perfusion SPECT/CT images collected retrospectively from the Nuclear Medicine Facility of Botucatu Medical School's Clinics Hospital in São Paulo, Brazil, were analyzed. Anatomical lung impairments (emphysema, collapsed and infiltrated tissue) and the functional percentage of the lungs (blood perfusion) were quantified from CT and SPECT images, with the aid of the free, open-source software 3D Slicer. The results obtained with 3D Slicer (3D-TGP) were also compared to the total global perfusion of each patient's found on their medical report, obtained from visual inspection of planar images (2D-TGP). RESULTS: This research developed a novel and practical methodology for obtaining lungs' total global perfusion from SPECT/CT images in a semiautomatic manner. 3D-TGP versus 2D-TGP showed a bias of 7% with a variation up to 67% between the two methods. Perfusion percentage showed a weak positive correlation with infiltration (p = 0.0070 and ρ = 0.43) and collapsed parenchyma (p = 0.040 and ρ = 0.33). CONCLUSIONS: This research brings meaningful contributions to the scientific community because it used a free open-source software to quantify the lungs blood perfusion via SPECT/CT images and pointed that the relationship between parenchyma alterations and the organ's perfusion capability might not be so direct, given compensatory mechanisms.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA