1.
J Cardiovasc Electrophysiol ; 35(2): 301-306, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38100289

RESUMEN

BACKGROUND: Pacemaker-induced cardiomyopathy is a well described phenomenon in patients with preserved ejection fraction at the time of permanent pacemaker implant. One of the identified risk factors for pacemaker-induced cardiomyopathy is the degree of ventricular pacing burden. However, it is unclear how a high right ventricular pacing burden affects patients with depressed left ventricular function at the time of pacemaker implantation. We sought to assess the relationship between right ventricular pacing and change in left ventricular function over time. METHODS: We conducted an analysis of all patients who had received either a single or dual lead cardiac implantable electronic devices, excluding biventricular devices, and had a prior transthoracic echocardiogram demonstrating an ejection fraction of less than 50%. The primary end-point was the correlation between the percentage of ventricular pacing and the change in LV ejection fraction. RESULTS: Fifty eight patients with preceding heart failure had pacemakers implanted and had follow up echocardiograms. There was no correlation between the degree of ventricular pacing and the absolute change in LV function (r = .04, p = .979). None of the previously identified risk factors for pacemaker induced cardiomyopathy were predictive of a significant fall in ejection fraction. CONCLUSION: The degree of RV pacing and other established risk factors for pacemaker-induced cardiomyopathy in patients with normal left ventricular function at the time of implantation do not appear to carry the same risk in patients with pre-existing heart failure who receive either single or dual lead pacemakers.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Marcapaso Artificial , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Volumen Sistólico , Marcapaso Artificial/efectos adversos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Estimulación Cardíaca Artificial/efectos adversos , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 35(8): 1536-1547, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38812213

RESUMEN

INTRODUCTION: Left bundle branch area pacing is an alternative to biventricular pacing. In this study, we aim to summarize the available evidence on the feasibility, efficacy, and safety of left bundle branch block area pacing (LBBAP). OBJECTIVES: The study summarizes the available evidence on the feasibility, efficacy, and safety of left bundle branch block area pacing (LBBAP). BACKGROUND: Cardiac resynchronization therapy (CRT) reduced mortality and hospitalizations in heart failure (HF) patients with a left ventricular ejection fraction (LVEF) ≤ 35% and concomitant LBBB. Recently LBBAP has been studied as a more physiological alternative to achieve CRT. METHOD: A search of PubMed, EMBASE, and Cochrane databases were performed to identify studies examining the role of LBBAP for CRT in heart failure. Comprehensive meta-analysis version 4 was used for meta-regression to examine variables that contribute to data heterogeneity. RESULT: Eighteen studies, 17 observational and one randomized controlled trial (RCT) were examined. A total of 3906 HF patients who underwent CRT (2036 LBBAP vs. 1870 biventricular pacing [BVP]) were included. LBBAP was performed successfully in 90.4% of patients. Compared to baseline, LBBAP was associated with a reduction in QRS duration (MD: -47.23 ms 95% confidence interval [CI]: -53.45, -41.01), an increase in LVEF (MD: 15.22%, 95% CI: 13.5, 16.94), and a reduction in NYHA class (MD: -1.23, 95% CI: -1.41, -1.05). Compared to BVP, LBBAP was associated with a significant reduction in QRS duration (MD: -20.69 ms, 95% CI: -25.49, -15.88) and improvement in LVEF (MD: 4.78%, 95% CI: 3.30, 6.10). Furthermore, LBBAP was associated with a significant reduction in HF hospitalization (odds ratio [OR]: 0.44, 95% CI: 0.34, 0.56) and all-cause mortality (OR: 0.67, 95% CI: 0.52, 0.86) compared to BVP. CONCLUSION: LBBAP was associated with improved ventricular electrical synchrony compared to BVP, as well as better echocardiographic and clinical outcomes.


Asunto(s)
Bloqueo de Rama , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Función Ventricular Izquierda , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/mortalidad , Resultado del Tratamiento , Femenino , Masculino , Anciano , Terapia de Resincronización Cardíaca/mortalidad , Terapia de Resincronización Cardíaca/efectos adversos , Factores de Riesgo , Volumen Sistólico , Fascículo Atrioventricular/fisiopatología , Persona de Mediana Edad , Recuperación de la Función , Factores de Tiempo , Frecuencia Cardíaca , Potenciales de Acción
3.
J Cardiovasc Electrophysiol ; 35(6): 1185-1195, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38591763

RESUMEN

INTRODUCTION: Biventricular pacing (BiVp) improves outcomes in systolic heart failure patients with electrical dyssynchrony. BiVp is delivered from epicardial left ventricular (LV) and endocardial right ventricular (RV) electrodes. Acute electrical activation changes with different LV-RV stimulation offsets can help guide individually optimized BiVp programming. We sought to study the BiVp ventricular activation with different LV-RV offsets and compare with 12-lead ECG. METHODS: In five patients with BiVp (63 ± 17-year-old, 80% male, LV ejection fraction 27 ± 6%), we evaluated acute ventricular epicardial activation, varying LV-RV offsets in 20 ms increments from -40 to 80 ms, using electrocardiographic imaging (ECGI) to obtain absolute ventricular electrical uncoupling (VEUabs, absolute difference in average LV and average RV activation time) and total activation time (TAT). For each patient, we calculated the correlation between ECGI and corresponding ECG (3D-QRS-area and QRS duration) with different LV-RV offsets. RESULTS: The LV-RV offset to attain minimum VEUabs in individual patients ranged 20-60 ms. In all patients, a larger LV-RV offset was required to achieve minimum VEUabs (36 ± 17 ms) or 3D-QRS-area (40 ± 14 ms) than that for minimum TAT (-4 ± 9 ms) or QRS duration (-8 ± 11 ms). In individual patients, 3D-QRS-area correlated with VEUabs (r 0.65 ± 0.24) and QRS duration correlated with TAT (r 0.95 ± 0.02). Minimum VEUabs and minimum 3D-QRS-area were obtained by LV-RV offset within 20 ms of each other in all five patients. CONCLUSIONS: LV-RV electrical uncoupling, as assessed by ECGI, can be minimized by optimizing LV-RV stimulation offset. 3D-QRS-area is a surrogate to identify LV-RV offset that minimizes LV-RV uncoupling.


Asunto(s)
Potenciales de Acción , Terapia de Resincronización Cardíaca , Electrocardiografía , Valor Predictivo de las Pruebas , Función Ventricular Izquierda , Función Ventricular Derecha , Humanos , Masculino , Proyectos Piloto , Femenino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Frecuencia Cardíaca , Factores de Tiempo , Volumen Sistólico , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen
4.
J Card Fail ; 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38977056

RESUMEN

OBJECTIVES: To assess the association between the use of adaptive pacing on clinical and economic outcomes of cardiac resynchronization therapy (CRT) recipients in a real-world analysis. BACKGROUND: The adaptivCRT (aCRT) algorithm was shown in prior subgroup analyses of prospective trials to achieve clinical benefits, but a large prospective trial showed nonsignificant changes in the endpoint of mortality or hospitalizations due to heart failure. METHODS: CRT-implanted patients from the Optum Clinformatics database with ≥ 90 days of follow-up were included. Remote monitoring data were used to classify patients based on CRT setting-adaptive biventricular and left ventricular pacing (aCRT) vs standard biventricular pacing (Standard CRT). Inverse probability of treatment weighting was used to adjust for baseline differences between groups. Mortality, 30-day readmissions, health care use, and payer and patients' costs were evaluated post-implantation. RESULTS: This study included 2412 aCRT and 1638 Standard CRT patients (mean follow-up: 2.4 ± 1.4 years), with balanced baseline characteristics after adjustment. The aCRT group was associated with lower all-cause mortality rates (adjusted hazard ratio = 0.88 [95% confidence interval (CI):0.80, 0.96]), fewer all-cause 30-day readmissions (adjusted incidence rate ratio = 0.87 [CI:0.81, 0.94]), and fewer all-cause and HF-related inpatient, outpatient and emergency department visits. The aCRT cohort was also associated with lower all-cause outpatient payer-paid amounts and lower all-cause and HF-related inpatient and emergency department patient-paid amounts. CONCLUSIONS: In this retrospective analysis of a large real-world cohort, the use of an adaptive CRT algorithm was associated with lower mortality rates, reduced health care resource use and lower payer and patient costs.

5.
Rev Cardiovasc Med ; 25(2): 63, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39077345

RESUMEN

Background: Cardiac resynchronization therapy (CRT) is a well-established therapy for patients with heart failure (HF). However, 30% of HF patients do not show any improvement in clinical status after CRT implantation. In this study, we report our echocardiography-based CRT optimization methodology, in daily practice at our CRT referral center. Methods: We included 350 ambulatory patients, who were referred to our center for optimization after CRT implantation. A protocol-driven echocardiographic approach for adjusting mechanical dyssynchrony, whereby adjusting for ventriculoventricular (VV) delays with strain and atrioventricular (AV) delays with Doppler echocardiography was performed. We defined changes in left ventricular ejection fraction (LVEF) and New York Heart Association (NYHA) classes as outcome variables in the evaluation of the CRT outcomes. Results: Optimization was obtained in 288 (82%) patients. VV and AV timings were adjusted to 61% and 51%, respectively. In 3%, biventricular pacing was turned off and in 3% left ventricular (LV) only pacing was programmed. The LVEF and NYHA class showed significant improvements in all patients who underwent CRT optimization. Conclusions: CRT optimization remains valuable in improving LVEF and functional status measured using the NYHA class in all patients receiving CRT devices.

6.
J Nucl Cardiol ; 36: 101867, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38697386

RESUMEN

BACKGROUND: The segment of the latest mechanical contraction (LMC) does not always overlap with the site of the latest electrical activation (LEA). By integrating both mechanical and electrical dyssynchrony, this proof-of-concept study aimed to propose a new method for recommending left ventricular (LV) lead placements, with the goal of enhancing response to cardiac resynchronization therapy (CRT). METHODS: The LMC segment was determined by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) phase analysis. The LEA site was detected by vectorcardiogram. The recommended segments for LV lead placement were as follows: (1) the LMC viable segments that overlapped with the LEA site; (2) the LMC viable segments adjacent to the LEA site; (3) If no segment met either of the above, the LV lateral wall was recommended. The response was defined as ≥15% reduction in left ventricular end-systolic volume (LVESV) 6-months after CRT. Patients with LV lead located in the recommended site were assigned to the recommended group, and those located in the non-recommended site were assigned to the non-recommended group. RESULTS: The cohort comprised of 76 patients, including 54 (71.1%) in the recommended group and 22 (28.9%) in the non-recommended group. Among the recommended group, 74.1% of the patients responded to CRT, while 36.4% in the non-recommended group were responders (P = .002). Compared to pacing at the non-recommended segments, pacing at the recommended segments showed an independent association with an increased response by univariate and multivariable analysis (odds ratio 5.00, 95% confidence interval 1.73-14.44, P = .003; odds ratio 7.33, 95% confidence interval 1.53-35.14, P = .013). Kaplan-Meier curves showed that pacing at the recommended LV lead position demonstrated a better long-term prognosis. CONCLUSION: Our findings indicate that pacing at the recommended segments, by integrating of mechanical and electrical dyssynchrony, is significantly associated with an improved CRT response and better long-term prognosis.


Asunto(s)
Terapia de Resincronización Cardíaca , Ventrículos Cardíacos , Vectorcardiografía , Humanos , Terapia de Resincronización Cardíaca/métodos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Vectorcardiografía/métodos , Resultado del Tratamiento , Ventrículos Cardíacos/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca/métodos , Imagen de Perfusión Miocárdica/métodos , Prueba de Estudio Conceptual , Tomografía Computarizada de Emisión de Fotón Único , Dispositivos de Terapia de Resincronización Cardíaca
7.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38979560

RESUMEN

AIMS: Recommendations on cardiac resynchronization therapy (CRT) in patients with atrial fibrillation or flutter (AF) are based on less robust evidence than those in sinus rhythm (SR). We aimed to assess the efficacy of CRT upgrade in the BUDAPEST-CRT Upgrade trial population by their baseline rhythm. METHODS AND RESULTS: Heart failure patients with reduced ejection fraction (HFrEF) and previously implanted pacemaker (PM) or implantable cardioverter defibrillator (ICD) and ≥20% right ventricular (RV) pacing burden were randomized to CRT with defibrillator (CRT-D) upgrade (n = 215) or ICD (n = 145). Primary [HF hospitalization (HFH), all-cause mortality, or <15% reduction of left ventricular end-systolic volume] and secondary outcomes were investigated. At enrolment, 131 (36%) patients had AF, who had an increased risk for HFH as compared with those with SR [adjusted hazard ratio (aHR) 2.99; 95% confidence interval (CI) 1.26-7.13; P = 0.013]. The effect of CRT-D upgrade was similar in patients with AF as in those with SR [AF adjusted odds ratio (aOR) 0.06; 95% CI 0.02-0.17; P < 0.001; SR aOR 0.13; 95% CI 0.07-0.27; P < 0.001; interaction P = 0.29] during the mean follow-up time of 12.4 months. Also, it decreased the risk of HFH or all-cause mortality (aHR 0.33; 95% CI 0.16-0.70; P = 0.003; interaction P = 0.17) and improved the echocardiographic response (left ventricular end-diastolic volume difference -49.21 mL; 95% CI -69.10 to -29.32; P < 0.001; interaction P = 0.21). CONCLUSION: In HFrEF patients with AF and PM/ICD with high RV pacing burden, CRT-D upgrade decreased the risk of HFH and improved reverse remodelling when compared with ICD, similar to that seen in patients in SR.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/mortalidad , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Terapia de Resincronización Cardíaca/métodos , Anciano , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad , Resultado del Tratamiento , Persona de Mediana Edad , Función Ventricular Derecha , Función Ventricular Izquierda , Dispositivos de Terapia de Resincronización Cardíaca , Factores de Riesgo , Hospitalización/estadística & datos numéricos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Factores de Tiempo , Anciano de 80 o más Años
8.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38266248

RESUMEN

BACKGROUND AND AIMS: Right bundle branch block (RBBB) and resulting right ventricular (RV) electromechanical discoordination are thought to play a role in the disease process of subpulmonary RV dysfunction that frequently occur post-repair tetralogy of Fallot (ToF). We sought to describe this disease entity, the role of pulmonary re-valvulation, and the potential added value of RV cardiac resynchronization therapy (RV-CRT). METHODS: Two patients with repaired ToF, complete RBBB, pulmonary regurgitation, and significantly decreased RV function underwent echocardiography, cardiac magnetic resonance, and an invasive study to evaluate the potential for RV-CRT as part of the management strategy. The data were used to personalize the CircAdapt model of the human heart and circulation. Resulting Digital Twins were analysed to quantify the relative effects of RV pressure and volume overload and to predict the effect of RV-CRT. RESULTS: Echocardiography showed components of a classic RV dyssynchrony pattern which could be reversed by RV-CRT during invasive study and resulted in acute improvement in RV systolic function. The Digital Twins confirmed a contribution of electromechanical RV dyssynchrony to RV dysfunction and suggested improvement of RV contraction efficiency after RV-CRT. The one patient who underwent successful permanent RV-CRT as part of the pulmonary re-valvulation procedure carried improvements that were in line with the predictions based on his Digital Twin. CONCLUSION: An integrative diagnostic approach to RV dysfunction, including the construction of Digital Twins may help to identify candidates for RV-CRT as part of the lifetime management of ToF and similar congenital heart lesions.


Asunto(s)
Terapia de Resincronización Cardíaca , Tetralogía de Fallot , Disfunción Ventricular Derecha , Humanos , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Ventrículos Cardíacos , Ecocardiografía , Terapia de Resincronización Cardíaca/efectos adversos , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/terapia , Simulación por Computador
9.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38812433

RESUMEN

AIMS: Significant changes in tricuspid regurgitation (TR) and mitral regurgitation (MR) post-cardiac implantable electronic devices (CIEDs) are increasingly recognized. However, uncertainty remains as to whether the risk of CIED-associated TR and MR differs with right ventricular pacing (RVP) via CIED with trans-tricuspid RV leads, compared with cardiac resynchronization therapy (CRT), conduction system pacing (CSP), and leadless pacing (LP). The study aims to synthesize extant data on risk and prognosis of significant post-CIED TR and MR across pacing strategies. METHODS AND RESULTS: We searched PubMed, EMBASE, and Cochrane Library databases published until 31 October 2023. Significant post-CIED TR and MR were defined as ≥ moderate. Fifty-seven TR studies (n = 13 723 patients) and 90 MR studies (n = 14 387 patients) were included. For all CIED, the risk of post-CIED TR increased [pooled odds ratio (OR) = 2.46 and 95% CI = 1.88-3.22], while the risk of post-CIED MR reduced (OR = 0.74, 95% CI = 0.58-0.94) after 12 and 6 months of median follow-up, respectively. Right ventricular pacing via CIED with trans-tricuspid RV leads was associated with increased risk of post-CIED TR (OR = 4.54, 95% CI = 3.14-6.57) and post-CIED MR (OR = 2.24, 95% CI = 1.18-4.26). Binarily, CSP did not alter TR risk (OR = 0.37, 95% CI = 0.13-1.02), but significantly reduced MR (OR = 0.15, 95% CI = 0.03-0.62). Cardiac resynchronization therapy did not significantly change TR risk (OR = 1.09, 95% CI = 0.55-2.17), but significantly reduced MR with prevalence pre-CRT of 43%, decreasing post-CRT to 22% (OR = 0.49, 95% CI = 0.40-0.61). There was no significant association of LP with post-CIED TR (OR = 1.15, 95% CI = 0.83-1.59) or MR (OR = 1.31, 95% CI = 0.72-2.39). Cardiac implantable electronic device-associated TR was independently predictive of all-cause mortality [pooled hazard ratio (HR) = 1.64, 95% CI = 1.40-1.90] after median of 53 months. Mitral regurgitation persisting post-CRT independently predicted all-cause mortality (HR = 2.00, 95% CI = 1.57-2.55) after 38 months. CONCLUSION: Our findings suggest that, when possible, adoption of pacing strategies that avoid isolated trans-tricuspid RV leads may be beneficial in preventing incident or deteriorating atrioventricular valvular regurgitation and might reduce mortality.


Asunto(s)
Desfibriladores Implantables , Insuficiencia de la Válvula Mitral , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Marcapaso Artificial/efectos adversos , Pronóstico , Factores de Riesgo , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/fisiopatología
10.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38412340

RESUMEN

The DF-4 defibrillator standard has been rapidly adopted due to its convenience at implantation. There are however trade-offs compared to the traditional DF-1 standard that are underappreciated. This viewpoint outlines the advantages and limitations of current defibrillator lead standards that should be kept in mind, as they impact the options that are available to deal with issues that may arise.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia
11.
Circ J ; 88(7): 1118-1124, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38616125

RESUMEN

BACKGROUND: Despite an increased incidence of chronic heart failure (HF) and sudden cardiac death (SCD), the use of implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) is much lower in Japan than in Western countries. The HF Indication and SCD Prevention Trial Japan (HINODE) prospectively assessed the mortality rate, appropriately treated ventricular arrhythmias (VA), and HF in Japanese patients with a higher risk of HF. METHODS AND RESULTS: HINODE consisted of ICD, CRT-defibrillator (CRT-D), pacing, and non-device treatment cohorts. This subanalysis evaluated the impact of the implantation of high-voltage devices (HVD; ICD and CRT-D) in 171 Japanese patients. We compared all-cause mortality, VA, and HF events between elderly (age >70 years at study enrollment) and non-elderly HVD recipients. The estimated survival rate through 24 months in the HVD cohort was 85.8% (97.5% lower control limit 77.6%). The risk of all-cause mortality was increased for the elderly vs. non-elderly (hazard ratio [HR] 2.82; 95% confidence interval [CI] 1.01-7.91; P=0.039), but did not differ after excluding ICD patients with CRT-D indication (HR 2.32; 95% CI 0.79-6.78; P=0.11). There were no differences in VA and HF event-free rates between elderly and non-elderly HVD recipients (P=0.73 and P=0.55, respectively). CONCLUSIONS: Although elderly patients may have a higher risk of mortality in general, the benefit of HVD therapy in this group is comparable to that in non-elderly patients.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Anciano , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Masculino , Femenino , Japón/epidemiología , Anciano de 80 o más Años , Persona de Mediana Edad , Prevención Primaria , Estudios Prospectivos , Muerte Súbita Cardíaca/prevención & control , Factores de Edad , Factores de Riesgo , Pueblos del Este de Asia
12.
Circ J ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38960680

RESUMEN

BACKGROUND: This study compared the stability of the Medtronic Attain Stability Quad (ASQ), a novel quadripolar active fixation left ventricular (LV) lead with a side helix, to that of conventional quadripolar leads with passive fixation (non-ASQ) and evaluated their LV lead performance.Methods and Results: In all, 183 consecutive patients (69 ASQ, 114 non-ASQ) who underwent cardiac resynchronization therapy (CRT) between January 2018 and June 2021 were enrolled. Complications, including elevated pacing capture threshold (PCT) levels, phrenic nerve stimulation (PNS), and LV lead dislodgement, were analyzed during the postimplantation period until the first outpatient visit after discharge. The frequency of LV lead-related complications was significantly lower in the ASQ than non-ASQ group (14% vs. 30%, respectively; P=0.019). Specifically, LV lead dislodgement occurred only in the non-ASQ group, and elevated PCT levels were significantly lower in the ASQ group (7% vs. 23%; P=0.007). Kaplan-Meier analysis confirmed a significantly lower incidence of LV lead-related complications in the ASQ group (log-rank P=0.005). Cox multivariable regression analysis showed a significant reduction in lead-related complications associated with ASQ (hazard ratio 0.44; 95% confidence interval 0.23-0.83; P=0.011). CONCLUSIONS: The ASQ group exhibited fewer LV lead-related complications requiring reintervention and setting changes than the non-ASQ group. Thus, the ASQ may be a favorable choice for CRT device implantation.

13.
Cardiology ; : 1-12, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38643751

RESUMEN

INTRODUCTION: Cardiac implantable electronic devices (CIEDs), including pacemakers, defibrillators, and resynchronization devices, significantly enhance patient outcomes, reduce sudden cardiac death, and improve health-related quality of life. CIED implantation is associated to persistent shoulder dysfunction in a considerable number of patients one-year post-implantation. This may result in disability, diminished quality of life, work absenteeism, and negative psychological effects. Restoring upper extremity function after CIED implantation should be a standard of cardiovascular care. Our systematic scoping review aimed to summarize available evidence, addressing vital questions about safety, effectiveness, exercise type, and time of exercise initiation immediately after CIED implantation. METHODS: We conducted a comprehensive literature search in 5 electronic databases for original research in English, and a manual search on the references of included studies. We used Rayyan web application for study selection, and PRISMA-ScR to conduct and report the review. We assessed methodological quality using the Cochrane Risk of Bias Assessment Tool and Joanna Briggs Institute critical appraisal checklists. RESULTS: This review included 6 studies that used upper extremity pendular, range of motion, stretching and strengthening exercises. Initiation time varied from the first postoperative day to the second postoperative week. All studies showed significant association between active upper extremity exercise and reduced dysfunction and disability after CIED implantation. There were no significant differences in complication rates between control and experimental groups. CONCLUSION: A limited number of low-to-average quality studies suggest active upper extremity exercise immediately after CIED implantation is safe, effective at reducing dysfunction, and improves quality of life. Higher-quality studies are needed to validate these findings.

14.
BMC Cardiovasc Disord ; 24(1): 69, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38262994

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) has been a well-established treatment modality for moderate to severe left ventricular systolic dysfunction with left ventricular desynchrony. This is the pioneering study that analyses the cohort who underwent CRT implantation at the National Hospital of Sri Lanka (NHSL) in Colombo from 2005 to 2020. OBJECTIVES: This study was carried out to describe socio-demographic factors, improvements in clinical outcome (symptoms, electrocardiographic, and echocardiographic features), and post-CRT complications in the study population, as well as to determine the efficacy of CRT in heart failure. METHOD: A retrospective observational study was conducted on all the living patients who had undergone CRT implantation from 2005 to 2020. The data was gathered from all the consented patients who visited the device programming clinic using a physician-administered questionnaire and clinical records. Data was analyzed using SPSS 25, and significant statistics were assessed with the McNemer test, the Student T test, and the Chi-Squared test. RESULTS: The study included 50 patients with a mean age of 52.82+/- 11.66 years and female predominance (56%, n = 28). Idiopathic dilated cardiomyopathy (50%, n = 25) was the leading etiological factor, followed by ischemic cardiomyopathy (28%, n = 14). Clinical symptoms have improved significantly with CRT implantation (p < 0.001). A significant improvement was found in NYHA functional class (p < 0.001, 95% CI = 0.072 to 0.284), QRS width (p < 0.001, 95% CI = 0.229 to 0.534), ejection fraction (p < 0.001, 95% CI = - 16.437 to - 8.504), and LV EDD (p < 0.001, 95% CI = 2.89 to 9.24). Post-CRT complications included lead malfunction (6%, n = 3) and chronic (14%, n = 7), bleeding or hematoma (2%, n = 1), pocket erosion or infection (6%, n = 3), and infective endocarditis (2%, n = 1). CONCLUSION: According to the study, CRT significantly improves both clinical and functional outcomes in patients with moderate to severe heart failure.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Femenino , Adulto , Persona de Mediana Edad , Masculino , Sri Lanka , Instituciones de Atención Ambulatoria , Hospitales
15.
BMC Cardiovasc Disord ; 24(1): 376, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-39030503

RESUMEN

OBJECTIVE: To construct a nomogram for predicting the responsiveness of cardiac resynchronization therapy (CRT) in patients with chronic heart failure and verify its predictive efficacy. METHOD: A retrospective study was conducted including 109 patients with chronic heart failure who successfully received CRT from January 2018 to December 2022. According to patients after six months of the CRT preoperative improving acuity in the left ventricular ejection fraction is 5% or at least improve grade 1 NYHA heart function classification, divided into responsive group and non-responsive group. Clinical data of patients were collected, and LASSO regression analysis and multivariate logistic regression analysis were used to explore relative factors. A nomogram was constructed, and the predictive performance of the nomogram was evaluated using the calibration curve and decision curve analysis (DCA). RESULTS: Among the 109 patients, 61 were assigned to the CRT-responsive group, while 48 were assigned to the non-responsive group. LASSO regression analysis showed that left ventricular end-systolic volume, diffuse fibrosis, and left bundle branch block (LBBB) were independent factors for CRT responsiveness in patients with heart failure (P < 0.05). Based on the above three predictive factors, a nomogram was constructed. The ROC curve analysis showed that the area under the curve (AUC) was 0.865 (95% CI 0.794-0.935). The calibration curve analysis showed that the predicted probability of the nomogram is consistent with the actual occurrence rate. DCA showed that the line graph model has an excellent clinical net benefit rate. CONCLUSION: The nomogram constructed based on clinical features, laboratory, and imaging examinations in this study has high discrimination and calibration in predicting CRT responsiveness in patients with chronic heart failure.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Nomogramas , Valor Predictivo de las Pruebas , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/diagnóstico , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Enfermedad Crónica , Técnicas de Apoyo para la Decisión , Recuperación de la Función , Factores de Tiempo , Factores de Riesgo , Toma de Decisiones Clínicas
16.
Pacing Clin Electrophysiol ; 47(4): 533-541, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38477034

RESUMEN

BACKGROUND: Optimization of atrial-ventricular delay (AVD) during atrial sensing (SAVD) and pacing (PAVD) provides the most effective cardiac resynchronization therapy (CRT). We demonstrate a novel electrocardiographic methodology for quantifying electrical synchrony and optimizing SAVD/PAVD. METHODS: We studied 40 CRT patients with LV activation delay. Atrial-sensed to RV-sensed (As-RVs) and atrial-paced to RV-sensed (Ap-RVs) intervals were measured from intracardiac electrograms (IEGM). LV-only pacing was performed over a range of SAVD/PAVD settings. Electrical dyssynchrony (cardiac resynchronization index; CRI) was measured at each setting using a multilead ECG system placed over the anterior and posterior torso. Biventricular pacing, which included multiple interventricular delays, was also conducted in a subset of 10 patients. RESULTS: When paced LV-only, peak CRI was similar (93 ± 5% vs. 92 ± 5%) during atrial sensing or pacing but optimal PAVD was 61 ± 31 ms greater than optimal SAVD. The difference between As-RVs and Ap-RVs intervals on IEGMs (62 ± 31 ms) was nearly identical. The slope of the correlation line (0.98) and the correlation coefficient r (0.99) comparing the 2 methods of assessing SAVD-PAVD offset were nearly 1 and the y-intercept (0.63 ms) was near 0. During simultaneous biventricular (BiV) pacing at short AVD, SAVD and PAVD programming did not affect CRI, but CRI was significantly (p < .05) lower during atrial sensing at long AVD. CONCLUSIONS: A novel methodology for measuring electrical dyssynchrony was used to determine electrically optimal SAVD/PAVD during LV-only pacing. When BiV pacing, shorter AVDs produce better electrical synchrony.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Resultado del Tratamiento , Ventrículos Cardíacos , Dispositivos de Terapia de Resincronización Cardíaca , Atrios Cardíacos , Electrocardiografía/métodos , Insuficiencia Cardíaca/terapia
17.
Pacing Clin Electrophysiol ; 47(2): 336-341, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38269497

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) is indicated for patients with heart failure with reduced left ventricular ejection fraction (LVEF) and chronic right ventricular (RV) pacing burden ≥40% (pacing-induced cardiomyopathy, PICM). It is uncertain whether baseline RV pacing burden impacts response to CRT. METHODS: We conducted a retrospective study of all CRT upgrades for PICM at our hospital from January 2017 to December 2018. Univariate and multivariable-adjusted changes in LVEF, and echocardiographic response (≥10% improvement in LVEF) at 3-12 months post-CRT upgrade were compared in those with RV pacing burden ≥90% versus <90%. RESULTS: We included 75 patients (age 74 ± 11 years, 71% male) who underwent CRT upgrade for PICM. The baseline RV pacing burden was ≥90% in 56 patients (median 99% [IQR 98%-99%]), and <90% in 19 patients (median 79% [IQR 73%-87%]). Improvement in LVEF was greater in those with baseline RV pacing burden ≥90% versus <90% (15.7 ± 9.3% vs. 7.5 ± 9.6%, p = .003). Baseline RV pacing burden ≥90% was a strong predictor of an improvement in LVEF ≥10% after CRT upgrade both in univariate and multivariate-adjusted models (p = .005 and .02, respectively). CONCLUSION: A higher baseline RV pacing burden predicts a greater improvement in LVEF after CRT upgrade for PICM.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatías , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Volumen Sistólico/fisiología , Función Ventricular Izquierda , Estudios Retrospectivos , Resultado del Tratamiento , Cardiomiopatías/terapia , Insuficiencia Cardíaca/terapia , Estimulación Cardíaca Artificial
18.
Pacing Clin Electrophysiol ; 47(7): 966-973, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38830778

RESUMEN

BACKGROUND: Several studies have evaluated the role of QRS duration (QRSd) or QRS narrowing as a predictor of response to cardiac resynchronization therapy (CRT) to reduce nonresponders. AIM: Our study aimed to determine the correlation between the relative change in QRS index (QI) compared to clinical outcome and prognosis in patients who underwent CRT implantation. METHODS: A three-centers study involving 398 patients with a CRT device was conducted. Clinical, echocardiographic and pharmacological variables, QRSd before and after CRT implantation and QI were measured. RESULTS: In a 6-month follow-up, a significant improvement in left ventricular ejection fraction (LVEF), left ventricular end-diastolic and systolic volumes (LVEDV and LVESV) were observed. QI was related to reverse remodeling (multiple r-squared: 0.48, adjusted r-squared: 0.43, p = .001), and the cut-off value that best predicted LV reverse remodeling after 6 months of CRT was 12.25% (AUC 0.7, p = .001). At 24 months, a statistically significant difference was found between patients with a QI ≤ 12.25% and those with a QI > 12.25% regarding NYHA class worsening (p = .04). The mean of the QI of patients who died from cardiovascular causes was lower than patients who died of other causes (p = .0179). A correlation between pre-CRT QRSd/LVEDV and QI was observed (r = + 0.20; p = .0003). A higher QRSd/LVEDV ratio was associated with an improved LVEF, LVEDV, and LVESV (p < .0001) at follow-up. CONCLUSIONS: QI narrowing after CRT was related to greater echocardiographic reverse remodeling and a lower rate of adverse events (death or cardiovascular hospitalizations). The QI can improve the prediction of adverse events in a population with CRT regardless of comorbidities according to the Charlson Comorbidity Index. QI could be used to predict CRT response.


Asunto(s)
Terapia de Resincronización Cardíaca , Electrocardiografía , Humanos , Masculino , Femenino , Anciano , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Resultado del Tratamiento , Persona de Mediana Edad , Remodelación Ventricular , Pronóstico , Volumen Sistólico , Ecocardiografía
19.
Pacing Clin Electrophysiol ; 47(7): 974-976, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38529807

RESUMEN

3DQRSarea is a strong marker for cardiac resynchronization therapy and can be obtained by taking the (i) summation or the (ii) difference of the areas subtended by positive and negative deflections in X, Y, Z vectorcardiographic electrocardiogram (ECG) leads. We correlated both methods with the instantaneous-absolute-3D-voltage-time-integral (VTIQRS-3D). 3DQRSarea consistently underestimated the VTIQRS -3D, but the summation method was a closer and more reliable approximation. The dissimilarity was less apparent in left bundle branch block (r2 summation .996 vs. difference .972) and biventricular paced ECGs (r2 .996 vs. .957) but was more apparent in normal ECGs (r2 .988 vs. .653).


Asunto(s)
Vectorcardiografía , Humanos , Vectorcardiografía/métodos , Terapia de Resincronización Cardíaca/métodos , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Masculino , Electrocardiografía/métodos , Reproducibilidad de los Resultados , Femenino , Sensibilidad y Especificidad , Diagnóstico por Computador/métodos , Algoritmos
20.
Heart Vessels ; 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39039344

RESUMEN

Introduction Idiopathic left bundle branch block (iLBBB) is an uncommon finding. Its benignity has been increasingly questioned, though its natural history remains poorly clarified. Similarly, LBBB-cardiomyopathy (LBBB-CM) has been also increasingly recognized as a distinct entity, where electromechanical dyssynchrony seems to play a central role in left ventricular dysfunction (LVD) development. Still, it remains a scarcely studied topic. There is an urgent need for investigation and evidence reinforcement in these areas. OBJECTIVES: two main objectives: (1) to explore the natural history of "asymptomatic" iLBBB carriers; (2) to characterize the outcomes and therapeutic approach used in a "real-world" cohort of possible LBBB-CMP patients (pts). METHODS: tertiary care centre retrospective study of pts with iLBBB and possible LBBB-CMP, screened from a large hospital electrocardiographic database from 2011 to 2017 (LBBB = 347). To assign the 1st objective, only pts with left ventricular ejection fraction (LVEF) ≥ 50% and available follow-up (FU) data were included (n = 152). Regarding the 2nd objective, possible LBBB-CMP pts were selected and defined as iLBBB pts with LVD (LVEF < 50%) and no secondary causes for LVD (n = 53). Data were based on pts' careful review of medical records. RESULTS: focusing our 1st objective, 152 iLBBB carriers were identified. Median FU time were 8 years, and 61% were female. During FU, approximately 25% developed LVD, 20% needed ≥ 1 cardiovascular (CV) hospitalization, and 15% needed a cardiac device implantation. The majority (2/3) of pts with LVD on FU (n = 35) had no secondary causes for LVD, being classified as possible LBBB-CMP pts. Time-to-LVD analysis showed no differences between pts with a known cause for LVD vs LBBB-CMP pts (Log-rank = 0.713). Concerning the 2nd objective, 53 possible LBBB-CMP pts were identified. Median FU time were 10 years, and 51% were female. During the FU, 77% presented heart failure (HF) symptoms, and 42% needed ≥ 1 CV hospitalization, mainly due to HF. Half presented severe LVD at some point in time, and 55% needed a cardiac device, most of them a cardiac resynchronization therapy (CRT) device. Comparing CRT with non-CRT pts, no differences were found in terms of medical therapy, but better outcomes were observed in CRT group: LVEF improvement was higher (median LVEF improvement of 11% in non-CRT vs 27% in CRT; p < 0.001), and fully recovery from LVD was more frequent (50% of CRT vs 14% non-CRT; p = 0.028). CONCLUSION: our data strengthen current evidence on natural history of iLBBB, showing significant CV morbidity associated with the presence of iLBBB, and reinforces the need for a serial and proper FU of these carriers. Our data on "real-world" possible LBBB-CMP pts shows high rates of CV events, namely HF-related events, and supports the growing evidence pointing out CRT as this subgroup of pts' cornerstone of treatment. In conclusion, our work sheds additional light on these largely unknown topics and underlines the urgent need for larger and prospective studies addressing the identification of LVD development predictors in iLBBB carriers, as well as the establishment of diagnostic criteria and therapeutic approach for LBBB-CMP.

SELECCIÓN DE REFERENCIAS