Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 284
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 120(24): e2220200120, 2023 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-37279278

RESUMEN

The human cerebrum consists of a precise and stereotyped arrangement of lobes, primary gyri, and connectivity that underlies human cognition [P. Rakic, Nat. Rev. Neurosci. 10, 724-735 (2009)]. The development of this arrangement is less clear. Current models explain individual primary gyrification but largely do not account for the global configuration of the cerebral lobes [T. Tallinen, J. Y. Chung, J. S. Biggins, L. Mahadevan, Proc. Natl. Acad. Sci. U.S.A. 111, 12667-12672 (2014) and D. C. Van Essen, Nature 385, 313-318 (1997)]. The insula, buried in the depths of the Sylvian fissure, is unique in terms of gyral anatomy and size. Here, we quantitatively show that the insula has unique morphology and location in the cerebrum and that these key differences emerge during fetal development. Finally, we identify quantitative differences in developmental migration patterns to the insula that may underlie these differences. We calculated morphologic data in the insula and other lobes in adults (N = 107) and in an in utero fetal brain atlas (N = 81 healthy fetuses). In utero, the insula grows an order of magnitude slower than the other lobes and demonstrates shallower sulci, less curvature, and less surface complexity both in adults and progressively throughout fetal development. Spherical projection analysis demonstrates that the lenticular nuclei obstruct 60 to 70% of radial pathways from the ventricular zone (VZ) to the insula, forcing a curved migration to the insula in contrast to a direct radial pathway. Using fetal diffusion tractography, we identify radial glial fascicles that originate from the VZ and curve around the lenticular nuclei to form the insula. These results confirm existing models of radial migration to the cortex and illustrate findings that suggest differential insular and cerebral development, laying the groundwork to understand cerebral malformations and insular function and pathologies.


Asunto(s)
Desarrollo Fetal , Corteza Insular , Corteza Insular/anatomía & histología , Corteza Insular/diagnóstico por imagen , Corteza Insular/crecimiento & desarrollo , Imagen de Difusión Tensora , Humanos , Masculino , Femenino , Adulto Joven , Adulto
2.
Magn Reson Med ; 92(5): 2101-2111, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38968093

RESUMEN

PURPOSE: T1 mapping and T1-weighted contrasts have a complimentary but currently under utilized role in fetal MRI. Emerging clinical low field scanners are ideally suited for fetal T1 mapping. The advantages are lower T1 values which results in higher efficiency and reduced field inhomogeneities resulting in a decreased requirement for specialist tools. In addition the increased bore size associated with low field scanners provides improved patient comfort and accessibility. This study aims to demonstrate the feasibility of fetal brain T1 mapping at 0.55T. METHODS: An efficient slice-shuffling inversion-recovery echo-planar imaging (EPI)-based T1-mapping and postprocessing was demonstrated for the fetal brain at 0.55T in a cohort of 38 fetal MRI scans. Robustness analysis was performed and placental measurements were taken for validation. RESULTS: High-quality T1 maps allowing the investigation of subregions in the brain were obtained and significant correlation with gestational age was demonstrated for fetal brain T1 maps ( p < 0 . 05 $$ p<0.05 $$ ) as well as regions-of-interest in the deep gray matter and white matter. CONCLUSIONS: Efficient, quantitative T1 mapping in the fetal brain was demonstrated on a clinical 0.55T MRI scanner, providing foundations for both future research and clinical applications including low-field specific T1-weighted acquisitions.


Asunto(s)
Encéfalo , Imagen Eco-Planar , Feto , Edad Gestacional , Imagen por Resonancia Magnética , Placenta , Humanos , Femenino , Embarazo , Placenta/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Feto/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Diagnóstico Prenatal/métodos
3.
Magn Reson Med ; 91(3): 1165-1178, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37929768

RESUMEN

PURPOSE: This study evaluates the imaging performance of two-channel RF-shimming for fetal MRI at 3 T using four different local specific absorption rate (SAR) management strategies. METHODS: Due to the ambiguity of safe local SAR levels for fetal MRI, local SAR limits for RF shimming were determined based on either each individual's own SAR levels in standard imaging mode (CP mode) or the maximum SAR level observed across seven pregnant body models in CP mode. Local SAR was constrained either indirectly by further constraining the whole-body SAR (wbSAR) or directly by using subject-specific local SAR models. Each strategy was evaluated by the improvement of the transmit field efficiency (average |B1 + |) and nonuniformity (|B1 + | variation) inside the fetus compared with CP mode for the same wbSAR. RESULTS: Constraining wbSAR when using RF shimming decreases B1 + efficiency inside the fetus compared with CP mode (by 12%-30% on average), making it inefficient for SAR management. Using subject-specific models with SAR limits based on each individual's own CP mode SAR value, B1 + efficiency and nonuniformity are improved on average by 6% and 13% across seven pregnant models. In contrast, using SAR limits based on maximum CP mode SAR values across seven models, B1 + efficiency and nonuniformity are improved by 13% and 25%, compared with the best achievable improvement without SAR constraints: 15% and 26%. CONCLUSION: Two-channel RF-shimming can safely and significantly improve the transmit field inside the fetus when subject-specific models are used with local SAR limits based on maximum CP mode SAR levels in the pregnant population.


Asunto(s)
Feto , Imagen por Resonancia Magnética , Femenino , Embarazo , Humanos , Imagen por Resonancia Magnética/métodos , Feto/diagnóstico por imagen , Fantasmas de Imagen , Ondas de Radio , Simulación por Computador
4.
Magn Reson Med ; 92(3): 1263-1276, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38650351

RESUMEN

PURPOSE: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. METHODS: Deep learning-based detection of key brain landmarks on a whole-uterus echo planar imaging scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times, and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. A comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality, and the resulting image quality was conducted. RESULTS: Prospective automatic planning was performed in real-time without latency in all subjects. The landmark detection accuracy was 4.2 ± $$ \pm $$ 2.6 mm for the fetal eyes and 6.5 ± $$ \pm $$ 3.2 for the cerebellum, planning quality was 2.4/3 (compared to 2.6/3 for manual planning) and diagnostic image quality was 2.2 compared to 2.1 for manual planning. CONCLUSIONS: Real-time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way toward simplifying the acquisition of fetal MRI thereby widening the availability of this modality in nonspecialist centers.


Asunto(s)
Encéfalo , Feto , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/embriología , Imagen por Resonancia Magnética/métodos , Femenino , Embarazo , Feto/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Aprendizaje Profundo , Diagnóstico Prenatal/métodos , Estudios Prospectivos , Imagen Eco-Planar/métodos , Algoritmos , Interpretación de Imagen Asistida por Computador/métodos
5.
Exp Physiol ; 109(6): 980-991, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38606906

RESUMEN

Increasing placental perfusion (PP) could improve outcomes of growth-restricted fetuses. One way of increasing PP may be by using phosphodiesterase (PDE)-5 inhibitors, which induce vasodilatation of vascular beds. We used a combination of clinically relevant magnetic resonance imaging (MRI) techniques to characterize the impact that tadalafil infusion has on maternal, placental and fetal circulations. At 116-117 days' gestational age (dGA; term, 150 days), pregnant ewes (n = 6) underwent fetal catheterization surgery. At 120-123 dGA ewes were anaesthetized and MRI scans were performed during three acquisition windows: a basal state and then ∼15-75 min (TAD 1) and ∼75-135 min (TAD 2) post maternal administration (24 mg; intravenous bolus) of tadalafil. Phase contrast MRI and T2 oximetry were used to measure blood flow and oxygen delivery. Placental diffusion and PP were assessed using the Diffusion-Relaxation Combined Imaging for Detailed Placental Evaluation-'DECIDE' technique. Uterine artery (UtA) blood flow when normalized to maternal left ventricular cardiac output (LVCO) was reduced in both TAD periods. DECIDE imaging found no impact of tadalafil on placental diffusivity or fetoplacental blood volume fraction. Maternal-placental blood volume fraction was increased in the TAD 2 period. Fetal D O 2 ${D_{{{\mathrm{O}}_2}}}$ and V ̇ O 2 ${\dot V_{{{\mathrm{O}}_2}}}$ were not affected by maternal tadalafil administration. Maternal tadalafil administration did not increase UtA blood flow and thus may not be an effective vasodilator at the level of the UtAs. The increased maternal-placental blood volume fraction may indicate local vasodilatation of the maternal intervillous space, which may have compensated for the reduced proportion of UtA D O 2 ${D_{{{\mathrm{O}}_2}}}$ .


Asunto(s)
Oxígeno , Placenta , Circulación Placentaria , Tadalafilo , Arteria Uterina , Animales , Femenino , Tadalafilo/farmacología , Tadalafilo/administración & dosificación , Embarazo , Ovinos , Arteria Uterina/efectos de los fármacos , Placenta/efectos de los fármacos , Placenta/irrigación sanguínea , Circulación Placentaria/efectos de los fármacos , Oxígeno/sangre , Flujo Sanguíneo Regional/efectos de los fármacos , Inhibidores de Fosfodiesterasa 5/farmacología , Inhibidores de Fosfodiesterasa 5/administración & dosificación , Imagen por Resonancia Magnética , Feto/irrigación sanguínea , Feto/efectos de los fármacos
6.
Eur Radiol ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39210162

RESUMEN

OBJECTIVES: With SARS-CoV-2 evolving, disease severity and presentation have changed due to changes in mechanisms of entry and effector site as well as due to effects of vaccination- and/or infection-acquired immunity. We re-assessed fetal lung pathology in pregnancies with uncomplicated SARS-CoV-2 infections during the late, omicron-dominated pandemic phase to inform disease understanding and pregnancy consultation. METHODS: In this case-control study, fetal lung volumes were assessed by fetal MRI in 24 pregnancies affected by mild maternal SARS-CoV-2 infection during the omicron-dominated pandemic phase with prevailing immunity through vaccination and/or prior SARS-CoV-2 infection. RESULTS: Fetal lung volumes (normalized to estimated fetal weight) in 24 pregnancies (GA 33.3 ± 3.8, 12 female fetuses) following mild, uncomplicated SARS-CoV-2 infection did not differ significantly from both, published reference values (96.3% ± 22.5% of 50th percentile reference values, p = 0.43), or fetal lung volumes of a site-specific, non-COVID control group (n = 15, 94.2% ± 18.5%, p = 0.76). Placental assessment revealed no group differences in thrombotic changes or placental heterogeneity (p > 0.05, respectively), and fetal lung volume did not correlate with placental heterogeneity when adjusting for gestational age at scan (p > 0.05). CONCLUSION: Assessment of fetal lung volume by MRI revealed unaffected lung growth in pregnancies affected by uncomplicated SARS-CoV-2 infection in the omicron-dominated pandemic phase in the presence of prevailing hybrid immunity. This finding contrasts sharply with the observed reduction in fetal lung volume following maternal alpha-variant infection in the pre-vaccination era and might reflect tropism- as well as immunity-related effects. KEY POINTS: Question: Is fetal lung development affected by mild maternal SARS-CoV-2 infection during the omicron-dominated phase of the pandemic? FINDINGS: Fetal lung volume in 24 affected pregnancies did not differ significantly from published reference values or fetal lung volumes in 15 site-specific, non-COVID-affected control pregnancies. CLINICAL RELEVANCE: Preserved fetal lung volume following mild maternal SARS-CoV-2 infection during the omicron-dominated phase contrasts with previous findings of reduced volume in unvaccinated pregnancies during the alpha-dominated pandemic phase. These observations might reflect tropism- as well as immunity-related effects.

7.
Ultrasound Obstet Gynecol ; 64(2): 236-244, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38348601

RESUMEN

OBJECTIVES: T2*-weighted magnetic resonance imaging (MRI) sequences have been identified as non-invasive tools with which to study placental oxygenation in vivo. This study aimed to use these to investigate both static and dynamic responses to hyperoxia of the normal placenta across gestation. METHODS: We conducted a single-center prospective study including 52 uncomplicated pregnancies. Two T2*-weighted sequences (T2* relaxometry) were performed, one before and one after maternal hyperoxia. The distribution of placental T2* values was modeled by fitting a gamma probability density function (T2* ~ Γ α ß ), describing the structure of the histogram using the mean T2* value, the shape parameter (α) and the rate (ß). A dynamic acquisition (blood-oxygen-level-dependent (BOLD) MRI) was also performed before and during maternal oxygen supply, until placental oxygen saturation had been achieved. The signal change over time was modeled using a sigmoid function, to determine the intensity of enhancement (ΔBOLD (% with respect to baseline)), a temporal variation coefficient (λ (min-1), controlling the slope of the curve) and the maximum steepness (Vmax (% of placental enhancement/min)). RESULTS: The histogram analysis of the T2* values in normoxia showed a whole-placenta variation, with a decreasing linear trend in the mean T2* value (Pearson's correlation coefficient (R) = -0.83 (95% CI, -0.9 to -0.71), P < 0.001), along with an increasingly peaked and narrower distribution of T2* values with advancing gestation. After maternal hyperoxia, the mean T2* ratios (mean T2*hyperoxia/mean T2*baseline) were positively correlated with gestational age, while the other histogram parameters remained stable, suggesting a translation of the histogram towards higher values with a similar appearance after maternal hyperoxia. ΔBOLD showed a non-linear increase across gestation. Conversely, λ showed an inverted trend across gestation, with a weaker correlation (R = -0.33 (95% CI, -0.58 to -0.02), P = 0.04, R2 = 0.1). As a combination of ΔBOLD and λ, the changes in Vmax throughout gestation were influenced mainly by the changes in ΔBOLD and showed a positive non-linear correlation with gestational age. CONCLUSIONS: Our results suggest that the decrease in the T2* placental signal as gestation progresses does not reflect placental dysfunction. The BOLD dynamic signal change is representative of a free-diffusion model of oxygenation and highlights the increasing differences in oxygen saturation between mother and fetus as gestation progresses (ΔBOLD) and in the placental permeability to oxygen (λ). © 2024 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Hiperoxia , Imagen por Resonancia Magnética , Placenta , Humanos , Femenino , Embarazo , Placenta/diagnóstico por imagen , Placenta/metabolismo , Hiperoxia/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Adulto , Edad Gestacional , Oxígeno/metabolismo
8.
Ultrasound Obstet Gynecol ; 63(3): 385-391, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-37676105

RESUMEN

OBJECTIVES: It has been suggested previously that the presence of Probst bundles (PB) in cases with a short corpus callosum (SCC) on diffusion tensor imaging (DTI) may help to differentiate between corpus callosal (CC) dysplasia and a variant of normal CC development. The objectives of this study were to compare DTI parameters between cases of SCC vs normal CC and between cases of SCC with PB (SCC-PB+) vs SCC without PB (SCC-PB-). METHODS: This was a retrospective study of patients referred to the Necker Hospital in Paris, France, for magnetic resonance imaging (MRI) evaluation of an apparently isolated SCC detected by sonography between November 2016 and December 2022 (IRB: 00011928). MRI was performed using a 1.5-Tesla Signa system. T2-weighted axial and sagittal sequences of the fetal brain were used to measure the length and thickness of the CC. 16-direction DTI axial brain sequences were performed to identify the presence of PB and to generate quantitative imaging parameters (fractional anisotropy (FA) and apparent diffusion coefficient (ADC)) of the entire CC, genu, body and splenium. Cases in which other associated brain abnormalities were detected on MRI were excluded. Cases were matched for fetal gender and gestational age with controls in a 1:3 ratio. Control cases were normal fetuses included in the LUMIERE on the FETUS trial (NCT04142606) that underwent the same DTI evaluation of the brain. Comparisons between SCC and normal CC cases, and between SCC-PB+ and SCC-PB- cases were performed using ANOVA and adjusted for potential confounders using ANCOVA. RESULTS: Twenty-two SCC cases were included and compared with 66 fetuses with a normal CC. In 10/22 (45.5%) cases of SCC, PB were identified. As expected, dimensions of the CC were significantly smaller in SCC compared with normal CC cases (all P < 0.01). In SCC-PB+ vs SCC-PB- cases, FA values were significantly lower in the entire CC (median, 0.21 (range, 0.19-0.24) vs 0.24 (range, 0.22-0.28); P < 0.01), genu (median, 0.21 (range, 0.15-0.29) vs 0.24 (range, 0.17-0.29); P = 0.04), body (median, 0.21 (range, 0.18-0.23) vs 0.23 (range, 0.21-0.27); P = 0.04) and splenium (median, 0.22 (range, 0.16-0.30) vs 0.25 (range, 0.20-0.29); P = 0.03). ADC values were significantly higher in the entire CC, genu and body in SCC-PB+ vs SCC-PB- cases (all P < 0.05). In SCC-PB+ cases, all FA values were significantly lower, and ADC values in the CC body were significantly higher compared with normal CC cases (all P < 0.05). In SCC-PB- cases, there was no significant difference in FA and ADC compared with normal CC cases (all P > 0.05). CONCLUSIONS: Fetal DTI evaluation of the CC showed that FA values were significantly lower and ADC values tended to be significantly higher in SCC-PB+ compared with normal CC cases. This may highlight alterations of the white matter microstructure in SCC-PB+. In contrast, isolated SCC-PB- did not demonstrate significant changes in DTI parameters, strengthening the possibility that this is a normal CC variant. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Cuerpo Calloso , Imagen de Difusión Tensora , Femenino , Humanos , Embarazo , Cuerpo Calloso/diagnóstico por imagen , Imagen por Resonancia Magnética , Atención Prenatal , Estudios Retrospectivos , Ensayos Clínicos como Asunto
9.
Neuroradiology ; 66(7): 1213-1223, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38720066

RESUMEN

PURPOSE: To describe fetal brain Magnetic Resonance Imaging (MRI) findings in a large series of monochorionic (MC) pregnancies complicated by Twin Anemia-Polycythemia Sequence (TAPS) prenatally diagnosed, so to characterize the potential intracranial complications associated with this condition, their frequency and potential treatment options. METHODS: This is a retrospective study of MC twin pregnancies complicated by TAPS and undergone fetal MRI in a single institution from 2006 to 2023. MRI control was performed and post-natal ultrasound (US) or MRI were available. RESULTS: 1250 MC pregnancies were evaluated in our institution. 50 pregnancies (4%) were diagnosed with TAPS, 29 underwent a fetal brain MRI. 13/29 pregnancies (44.8%) demonstrated brain findings at MRI in at least a twin. Neuroradiological findings were detected in 14/57 twins (24.6%). We detected four main categories of findings: hemorrhagic lesions, T2-weighted white-matter hyperintensities (WMH), brain edema-swelling and venous congestion. Nineteen findings were present in the anemic and three in the polycythemic twins, with a statistically significant ratio between the two groups (p-value = 0.01). Intrauterine MRI follow-up demonstrated the sequalae of hemorrhagic lesions. A complete regression of brain swelling, veins prominence and T2-WMHs was demonstrated after treatment. Postnatal imaging confirmed prenatal features. CONCLUSIONS: Our work demonstrates that TAPS-related MRI anomalies consisted in edematous/hemorrhagic lesions that occur mostly in anemic rather than in polycythemic twins. Fetoscopic laser surgery could have a potential decongestant role. Therefore, prenatal MRI may help in counselling and management in TAPS pregnancies, especially for the planning of therapy and the monitoring of its efficacy.


Asunto(s)
Transfusión Feto-Fetal , Imagen por Resonancia Magnética , Humanos , Femenino , Embarazo , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Transfusión Feto-Fetal/diagnóstico por imagen , Transfusión Feto-Fetal/complicaciones , Adulto , Embarazo Gemelar , Diagnóstico Prenatal/métodos , Policitemia/diagnóstico por imagen , Anemia/diagnóstico por imagen
10.
BMC Pregnancy Childbirth ; 24(1): 122, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38336714

RESUMEN

BACKGROUND: According to prenatal ultrasonographic studies, single umbilical artery may be present alone or in association with other fetal abnormalities. So far, the exact pathogenesis of bladder exstrophy is unclear. Some scholars believe that bladder exstrophy and cloacal exstrophy should be regarded as a disease spectrum to explore their pathogenesis. If bladder exstrophy and cloacal exstrophy are regarded as the same disease spectrum, then we can speculate that the single umbilical artery should have the probability of being accompanied by bladder exstrophy at the same time. CASE PRESENTATION: For the first time, we report a rare case of fetal bladder exstrophy with single umbilical artery in single pregnancy. This patient underwent targeted color Doppler ultrasound at 26 weeks of pregnancy which first suspected bladder exstrophy with single umbilical artery and fetal MRI for diagnosis at 38 + 3 weeks of pregnancy which confirmed the suspicion. After the diagnosis was confirmed, the patient was scheduled for a multidisciplinary discussion. Ultimately the patient opted for induced fetal demise at 38 + 5 weeks of pregnancy and the physical appearance of the fetal demise affirmed previous ultrasound and MRI examination results. CONCLUSIONS: Our report is the first finding of single umbilical artery combined with bladder exstrophy in a singleton pregnancy. Accordingly, our case enhances the evidence that cloacal exstrophy and bladder exstrophy should be treated as the same disease spectrum. In addition, we conducted a literature review on the diagnostic progress of single umbilical artery combined with bladder exstrophy, hoping to provide useful references for the diagnosis of this disease.


Asunto(s)
Extrofia de la Vejiga , Arteria Umbilical Única , Embarazo , Femenino , Humanos , Extrofia de la Vejiga/complicaciones , Extrofia de la Vejiga/diagnóstico por imagen , Extrofia de la Vejiga/patología , Ultrasonografía Prenatal/métodos , Atención Prenatal , Muerte Fetal
11.
Acta Obstet Gynecol Scand ; 103(3): 512-521, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38009386

RESUMEN

INTRODUCTION: Spontaneous preterm birth prior to 32 weeks' gestation accounts for 1% of all deliveries and is associated with high rates of morbidity and mortality. A total of 70% are associated with chorioamnionitis which increases the incidence of morbidity, but for which there is no noninvasive antenatal test. Fetal adrenal glands produce cortisol and dehydroepiandosterone-sulphate which upregulate prior to spontaneous preterm birth. Ultrasound suggests that adrenal volumes may increase prior to preterm birth, but studies are limited. This study aimed to: (i) demonstrate reproducibility of magnetic resonance imaging (MRI) derived adrenal volumetry; (ii) derive normal ranges of total adrenal volumes, and adrenal: body volume for normal; (iii) compare with those who have spontaneous very preterm birth; and (iv) correlate with histopathological chorioamnionitis. MATERIAL AND METHODS: Patients at high risk of preterm birth prior to 32 weeks were prospectively recruited, and included if they did deliver prior to 32 weeks; a control group who delivered an uncomplicated pregnancy at term was also recruited. T2 weighted images of the entire uterus were obtained, and a deformable slice-to-volume method was used to reconstruct the fetal abdomen. Adrenal and body volumes were obtained via manual segmentation, and adrenal: body volume ratios generated. Normal ranges were created using control data. Differences between groups were investigated accounting for the effect of gestation by use of regression analysis. Placental histopathology was reviewed for pregnancies delivering preterm. RESULTS: A total of 56 controls and 26 cases were included in the analysis. Volumetry was consistent between observers. Adrenal volumes were not higher in the case group (p = 0.2); adrenal: body volume ratios were higher (p = 0.011), persisting in the presence of chorioamnionitis (p = 0.017). A cluster of three pairs of adrenal glands below the fifth centile were noted among the cases all of whom had a protracted period at risk of preterm birth prior to MRI. CONCLUSIONS: Adrenal: body volume ratios are significantly larger in fetuses who go on to deliver preterm than those delivering at term. Adrenal volumes were not significantly larger, we hypothesize that this could be due to an adrenal atrophy in fetuses with fulminating chorioamnionitis. A straightforward relationship of adrenal size being increased prior to preterm birth should not be assumed.


Asunto(s)
Corioamnionitis , Nacimiento Prematuro , Embarazo , Femenino , Humanos , Recién Nacido , Nacimiento Prematuro/diagnóstico por imagen , Corioamnionitis/diagnóstico por imagen , Proyectos Piloto , Reproducibilidad de los Resultados , Placenta , Feto
12.
BMC Med Imaging ; 24(1): 52, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38429666

RESUMEN

This study explores the potential of 3D Slice-to-Volume Registration (SVR) motion-corrected fetal MRI for craniofacial assessment, traditionally used only for fetal brain analysis. In addition, we present the first description of an automated pipeline based on 3D Attention UNet trained for 3D fetal MRI craniofacial segmentation, followed by surface refinement. Results of 3D printing of selected models are also presented.Qualitative analysis of multiplanar volumes, based on the SVR output and surface segmentations outputs, were assessed with computer and printed models, using standardised protocols that we developed for evaluating image quality and visibility of diagnostic craniofacial features. A test set of 25, postnatally confirmed, Trisomy 21 fetal cases (24-36 weeks gestational age), revealed that 3D reconstructed T2 SVR images provided 66-100% visibility of relevant craniofacial and head structures in the SVR output, and 20-100% and 60-90% anatomical visibility was seen for the baseline and refined 3D computer surface model outputs respectively. Furthermore, 12 of 25 cases, 48%, of refined surface models demonstrated good or excellent overall quality with a further 9 cases, 36%, demonstrating moderate quality to include facial, scalp and external ears. Additional 3D printing of 12 physical real-size models (20-36 weeks gestational age) revealed good/excellent overall quality in all cases and distinguishable features between healthy control cases and cases with confirmed anomalies, with only minor manual adjustments required before 3D printing.Despite varying image quality and data heterogeneity, 3D T2w SVR reconstructions and models provided sufficient resolution for the subjective characterisation of subtle craniofacial features. We also contributed a publicly accessible online 3D T2w MRI atlas of the fetal head, validated for accurate representation of normal fetal anatomy.Future research will focus on quantitative analysis, optimizing the pipeline, and exploring diagnostic, counselling, and educational applications in fetal craniofacial assessment.


Asunto(s)
Feto , Imagen por Resonancia Magnética , Humanos , Estudios de Factibilidad , Feto/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Edad Gestacional , Imagenología Tridimensional/métodos , Cuero Cabelludo , Procesamiento de Imagen Asistido por Computador/métodos
13.
Hum Brain Mapp ; 44(4): 1593-1602, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36421003

RESUMEN

This work presents detailed anatomic labels for a spatiotemporal atlas of fetal brain Diffusion Tensor Imaging (DTI) between 23 and 30 weeks of post-conceptional age. Additionally, we examined developmental trajectories in fractional anisotropy (FA) and mean diffusivity (MD) across gestational ages (GA). We performed manual segmentations on a fetal brain DTI atlas. We labeled 14 regions of interest (ROIs): cortical plate (CP), subplate (SP), Intermediate zone-subventricular zone-ventricular zone (IZ/SVZ/VZ), Ganglionic Eminence (GE), anterior and posterior limbs of the internal capsule (ALIC, PLIC), genu (GCC), body (BCC), and splenium (SCC) of the corpus callosum (CC), hippocampus, lentiform Nucleus, thalamus, brainstem, and cerebellum. A series of linear regressions were used to assess GA as a predictor of FA and MD for each ROI. The combination of MD and FA allowed the identification of all ROIs. Increasing GA was significantly associated with decreasing FA in the CP, SP, IZ/SVZ/IZ, GE, ALIC, hippocampus, and BCC (p < .03, for all), and with increasing FA in the PLIC and SCC (p < .002, for both). Increasing GA was significantly associated with increasing MD in the CP, SP, IZ/SVZ/IZ, GE, ALIC, and CC (p < .03, for all). We developed a set of expert-annotated labels for a DTI spatiotemporal atlas of the fetal brain and presented a pilot analysis of developmental changes in cerebral microstructure between 23 and 30 weeks of GA.


Asunto(s)
Encéfalo , Imagen de Difusión Tensora , Humanos , Embarazo , Femenino , Imagen de Difusión Tensora/métodos , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Cuerpo Calloso , Edad Gestacional , Anisotropía
14.
Magn Reson Med ; 90(6): 2306-2320, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37465882

RESUMEN

PURPOSE: To improve motion robustness of functional fetal MRI scans by developing an intrinsic real-time motion correction method. MRI provides an ideal tool to characterize fetal brain development and growth. It is, however, a relatively slow imaging technique and therefore extremely susceptible to subject motion, particularly in functional MRI experiments acquiring multiple Echo-Planar-Imaging-based repetitions, for example, diffusion MRI or blood-oxygen-level-dependency MRI. METHODS: A 3D UNet was trained on 125 fetal datasets to track the fetal brain position in each repetition of the scan in real time. This tracking, inserted into a Gadgetron pipeline on a clinical scanner, allows updating the position of the field of view in a modified echo-planar imaging sequence. The method was evaluated in real-time in controlled-motion phantom experiments and ten fetal MR studies (17 + 4-34 + 3 gestational weeks) at 3T. The localization network was additionally tested retrospectively on 29 low-field (0.55T) datasets. RESULTS: Our method achieved real-time fetal head tracking and prospective correction of the acquisition geometry. Localization performance achieved Dice scores of 84.4% and 82.3%, respectively for both the unseen 1.5T/3T and 0.55T fetal data, with values higher for cephalic fetuses and increasing with gestational age. CONCLUSIONS: Our technique was able to follow the fetal brain even for fetuses under 18 weeks GA in real-time at 3T and was successfully applied "offline" to new cohorts on 0.55T. Next, it will be deployed to other modalities such as fetal diffusion MRI and to cohorts of pregnant participants diagnosed with pregnancy complications, for example, pre-eclampsia and congenital heart disease.


Asunto(s)
Feto , Imagen por Resonancia Magnética , Femenino , Humanos , Embarazo , Estudios Prospectivos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Feto/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Movimiento (Física)
15.
Magn Reson Med ; 90(6): 2572-2591, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37667645

RESUMEN

PURPOSE: Developing a general framework with a novel stochastic offset strategy for the design of optimized RF pulses and time-varying spatially non-linear ΔB0 shim array fields for restricted slice excitation and refocusing with refined magnetization profiles within the intervals of the fixed voxels. METHODS: Our framework uses the decomposition property of the Bloch equations to enable joint design of RF-pulses and shim array fields for restricted slice excitation and refocusing with auto-differentiation optimization. Bloch simulations are performed independently on orthogonal basis vectors, Mx, My, and Mz, which enables designs for arbitrary initial magnetizations. Requirements for refocusing pulse designs are derived from the extended phase graph formalism obviating time-consuming sub-voxel isochromatic simulations to model the effects of crusher gradients. To refine resultant slice-profiles because of voxelwise optimization functions, we propose an algorithm that stochastically offsets spatial points at which loss is computed during optimization. RESULTS: We first applied our proposed design framework to standard slice-selective excitation and refocusing pulses in the absence of non-linear ΔB0 shim array fields and compared them against pulses designed with Shinnar-Le Roux algorithm. Next, we demonstrated our technique in a simulated setup of fetal brain imaging in pregnancy for restricted-slice excitation and refocusing of the fetal brain. CONCLUSIONS: Our proposed framework for optimizing RF pulse and time-varying spatially non-linear ΔB0 shim array fields achieve high fidelity restricted-slice excitation and refocusing for fetal MRI, which could enable zoomed fast-spin-echo-MRI and other applications.


Asunto(s)
Aumento de la Imagen , Imagen por Resonancia Magnética , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Fantasmas de Imagen
16.
Eur Radiol ; 33(3): 1698-1706, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36271920

RESUMEN

OBJECTIVES: To evaluate the feasibility of Doppler-ultrasound (DUS)-gated 4D flow MRI of the fetal great thoracic vessels at 3T in a clinical setting. METHODS: Sixteen consecutive fetuses (range 30+4-38+5 weeks) with (n = 11) and without (n = 5) cardiovascular anomalies underwent 4D flow MRI of the great thoracic vessels at 3T. Direct fetal cardiac gating was obtained using a MR-compatible DUS device. 4D flow MRI-based visualisation and quantification of four target regions (ascending aorta (AAo), descending aorta (DAo), main pulmonary artery (MPA), and ductus arteriosus (DA)) were performed using dedicated software. RESULTS: Fetal 4D flow MRI of the great thoracic vessels was successful in 12/16 fetuses (75%) by adopting clinical 4D flow MR protocols in combination with direct fetal cardiac DUS-gating. Four datasets were excluded due to artefacts by fetal movement or maternal breathing. 4D flow MRI-derived time-velocity curves revealed typical arterial blood flow patterns in the aorta. 4D flow quantification was achieved for the pre-defined target regions. Average velocity and flow volume were 21.1 ± 5.2 cm/s and 6.0 ± 3.1 mL/s in the AAo, 24.3 ± 6.7 cm/s and 8.4 ± 3.7 mL/s in the DAo, 21.9 ± 6.4 cm/s and 7.8 ± 4.2 mL/s in the MPA, and 23.4 ± 4.7 cm/s and 5.9 ± 3.6 mL/s in the DA, respectively. CONCLUSIONS: Combination of DUS-gating of the fetal heart and 4D flow MRI allows comprehensive visualisation and quantification of haemodynamics in the fetal great thoracic vessels. DUS-gated fetal 4D flow MRI may provide a new diagnostic approach for prenatal assessment of blood flow haemodynamics. KEY POINTS: • Fetal cardiac Doppler-ultrasound (DUS) gating and 4D flow MRI can be successfully combined. • DUS-gated fetal 4D flow MRI allowed visualisation and evaluation of streamline directionality, illustration of blood flow variations, and pulsatile arterial waveforms in the target vessels. • 4D flow MRI-based visualisation and quantification of the fetal great thoracic vessels were successful and flow metrics agreed with echocardiographic reference values.


Asunto(s)
Corazón Fetal , Imagen por Resonancia Magnética , Embarazo , Femenino , Humanos , Estudios de Factibilidad , Edad Gestacional , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiología , Arteria Pulmonar/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Aorta Torácica
17.
AJR Am J Roentgenol ; 220(3): 418-427, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36169547

RESUMEN

BACKGROUND. The opioid epidemic has profoundly affected infants born in the United States, as in utero opioid exposure increases the risk of cognitive and behavioral problems in childhood. Scarce literature has evaluated prenatal brain development in fetuses with opioid exposure in utero (hereafter opioid-exposed fetuses). OBJECTIVE. The purpose of this study is to compare opioid-exposed fetuses and fetuses without opioid exposure (hereafter unexposed fetuses) in terms of 2D biometric measurements of the brain and additional pregnancy-related assessments on fetal MRI. METHODS. This prospective case-control study included patients in the third trimester of pregnancy who underwent investigational fetal MRI at one of three U.S. academic medical centers from July 1, 2020, through December 31, 2021. Fetuses were classified as opioid exposed or unexposed in utero. Fourteen 2D biometric measurements of the fetal brain were manually assessed and used to derive four indexes. Measurements and indexes were compared between the two groups by use of multivariable linear regression models, which were adjusted for gestational age (GA), fetal sex, and nicotine exposure. Additional pregnancy-related findings on MRI were evaluated. RESULTS. The study included 65 women (mean age, 29.0 ± 5.5 [SD] years). A total of 28 fetuses (mean GA at the time of MRI, 32.2 ± 2.5 weeks) were opioid-exposed, and 37 fetuses (mean GA at the time of MRI, 31.9 ± 2.7 weeks) were unexposed. In the adjusted models, seven measurements were smaller (p < .05) in opioid-exposed fetuses than in unexposed fetuses: cerebral frontooccipital diameter (93.8 ± 7.4 vs 95.0 ± 8.6 mm), bone biparietal diameter (79.0 ± 6.0 vs 80.3 ± 7.1 mm), brain biparietal diameter (72.9 ± 7.7 vs 74.1 ± 8.6 mm), corpus callosum length (37.7 ± 4.0 vs 39.4 ± 3.7 mm), vermis height (18.2 ± 2.7 vs 18.8 ± 2.6 mm), anteroposterior pons measurement (11.6 ± 1.4 vs 12.1 ± 1.4 mm), and transverse cerebellar diameter (40.4 ± 5.1 vs 41.4 ± 6.0 mm). In addition, in the adjusted model, the frontoocccipital index was larger (p = .02) in opioid-exposed fetuses (0.04 ± 0.02) than in unexposed fetuses (0.04 ± 0.02). Remaining measures and indexes were not significantly different between the two groups (p > .05). Fetal motion, cervical length, and deepest vertical pocket of amniotic fluid were not significantly different (p > .05) between groups. Opioid-exposed fetuses, compared with unexposed fetuses, showed higher frequencies of both breech position (21% vs 3%, p = .03) and increased amniotic fluid volume (29% vs 8%, p = .04). CONCLUSION. Fetuses with opioid exposure in utero had a smaller brain size and altered fetal physiology. CLINICAL IMPACT. The findings provide insight into the impact of prenatal opioid exposure on fetal brain development.


Asunto(s)
Analgésicos Opioides , Encéfalo , Embarazo , Lactante , Humanos , Femenino , Adulto Joven , Adulto , Tercer Trimestre del Embarazo , Estudios de Casos y Controles , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Edad Gestacional , Feto , Ultrasonografía Prenatal/métodos
18.
Ultrasound Obstet Gynecol ; 61(3): 392-398, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36773302

RESUMEN

OBJECTIVE: To evaluate the prevalence of and risk factors for failure of fetal magnetic resonance imaging (MRI) due to maternal claustrophobia or malaise. METHODS: This retrospective cohort study included pregnant women who underwent fetal MRI for clinical indications or research purposes between January 2012 and December 2019 at a single center. One group included patients who completed the entire examination and the other group inlcuded patients who interrupted their MRI examination due to claustrophobia/malaise. We estimated the rate of MRI failure due to maternal claustrophobia/malaise and compared maternal and clinical variables between the two groups. Multiple logistic regression analysis was performed to identify independent risk factors for claustrophobia/malaise during MRI examination in pregnancy. RESULTS: Among 3413 patients who agreed to undergo fetal MRI, the prevalence of failure because of claustrophobia or malaise was 2.1%. The rate of claustrophobia/malaise in patients who underwent MRI for a clinical indication was lower compared to that in patients who underwent MRI for research purposes only (0.6% (4/696) vs 2.4% (65/2678); P = 0.003). Fetal MRI performed for research purposes only (adjusted odds ratio (aOR), 0.05 (95% CI, 0.01-0.48); P = 0.003), higher maternal age (aOR, 1.07 (95% CI, 1.02-1.12); P = 0.003) and later gestational age at the time of fetal MRI (aOR, 1.46 (95% CI, 1.16-2.04); P = 0.008) were independent risk factors for claustrophobia/malaise. Shorter fetal MRI duration (aOR, 0.77 (95% CI, 0.63-0.88); P = 0.001) was also associated with claustrophobia/malaise during the procedure. Body mass index, ethnic origin, multiple pregnancy, being parous and size of the magnetic bore were not associated with MRI failure due to claustrophobia/malaise. CONCLUSION: The rate of fetal MRI failure due to claustrophobia or malaise was found to be low, particularly when the examination was performed for a clinical indication, and should not be considered a common problem in the pregnant population. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Trastornos Fóbicos , Humanos , Embarazo , Femenino , Estudios Retrospectivos , Prevalencia , Factores de Riesgo , Trastornos Fóbicos/complicaciones , Trastornos Fóbicos/epidemiología , Imagen por Resonancia Magnética/métodos
19.
Ultrasound Obstet Gynecol ; 62(2): 175-184, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36864530

RESUMEN

OBJECTIVE: Adequate reference ranges of size of the corpus callosum (CC) are necessary to improve characterization of CC abnormalities and parental counseling. The objective of this study was to evaluate the methodology used in studies developing references charts for CC biometry. METHODS: We conducted a systematic review of studies on fetal CC biometry using a set of predefined quality criteria of study design, statistical analysis and reporting methods. We included observational studies whose primary aim was to create ultrasound or magnetic resonance imaging charts for CC size in a normal population of fetuses. Studies were scored against a predefined set of independently agreed methodological criteria, and an overall quality score was given for each study. RESULTS: Twelve studies met the inclusion criteria. Quality scores ranged between 17.4% and 95.7%. The greatest potential for bias was noted for the following items: sample selection and sample-size calculation, as only 17% of the studies were population-based and had consecutive or random recruitment of patients and with a justification of the sample size; number of measurements obtained for CC biometry, as only 17% of the studies performed more than one measurement per fetus and per scan; and description of characteristics of the study population, as only 8% of the studies clearly reported a minimum dataset of demographic characteristics. CONCLUSIONS: Our review demonstrates substantial heterogeneity in methods and final biometric values of the fetal CC across the evaluated studies. The use of uniform methodology of the highest quality is essential in order to define a 'short' CC and provide appropriate parental counseling. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Cuerpo Calloso , Ultrasonografía Prenatal , Embarazo , Femenino , Humanos , Cuerpo Calloso/diagnóstico por imagen , Edad Gestacional , Ultrasonografía Prenatal/métodos , Valores de Referencia , Biometría/métodos , Feto/diagnóstico por imagen
20.
Ultrasound Obstet Gynecol ; 62(2): 241-247, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36971038

RESUMEN

OBJECTIVES: Diffusion tensor imaging (DTI) of the fetal brain is a relatively new technique that allows evaluation of white matter tracts of the central nervous system throughout pregnancy, as well as in certain pathological conditions. The objectives of this study were to evaluate the feasibility of DTI of the spinal cord in utero and to examine gestational-age (GA)-related changes in DTI parameters during pregnancy. METHODS: This was a prospective study conducted between December 2021 and June 2022 in the LUMIERE Platform, Necker-Enfants Malades Hospital, Paris, France, as part of the LUMIERE SUR LE FETUS trial. Women with a pregnancy between 18 and 36 weeks of gestation without fetal or maternal abnormality were eligible for inclusion. Sagittal diffusion-weighted scans of the fetal spine were acquired, without sedation, using a 1.5-Tesla magnetic resonance imaging scanner. The imaging parameters were as follows: 15 non-collinear direction diffusion-weighted magnetic-pulsed gradients with a b-value 700 s/mm2 and one B0 image without diffusion-weighting; slice thickness, 3 mm; field of view (FOV), 36 mm; phase FOV, 1.00; voxel size, 4.5 × 2.8 × 3 mm3 ; number of slices, 7-10; repetition time, 2800 ms; echo time, minimum; and total acquisition time, 2.3 min. DTI parameters, including fractional anisotropy (FA) and apparent diffusion coefficient (ADC), were extracted at the cervical, upper thoracic, lower thoracic and lumbar levels of the spinal cord. Cases with motion degradation and those with aberrant reconstruction of the spinal cord on tractography were excluded. Pearson's correlation analysis was performed to evaluate GA-related changes of DTI parameters during pregnancy. RESULTS: During the study period, 42 pregnant women were included at a median GA of 29.3 (range, 22.0-35.7) weeks. Five (11.9%) patients were not included in the analysis because of fetal movement. Two (4.8%) patients with aberrant tractography reconstruction were also excluded from analysis. Acquisition of DTI parameters was feasible in all remaining cases (35/35). Increasing GA correlated with increasing FA averaged over the entire fetal spinal cord (r, 0.37; P < 0.01), as well as at the individual cervical (r, 0.519; P < 0.01), upper thoracic (r, 0.468; P < 0.01), lower thoracic (r, 0.425; P = 0.02) and lumbar (r, 0.427; P = 0.02) levels. There was no correlation between GA and ADC averaged over the entire spinal cord (r, 0.01; P = 0.99) or at the individual cervical (r, -0.109; P = 0.56), upper thoracic (r, -0.226; P = 0.22), lower thoracic (r, -0.052; P = 0.78) or lumbar (r, -0.11; P = 0.95) levels. CONCLUSIONS: This study shows that DTI of the spinal cord is feasible in normal fetuses in typical clinical practice and allows extraction of DTI parameters of the spinal cord. There is a significant GA-related change in FA in the fetal spinal cord during pregnancy, which may result from decreasing water content as observed during myelination of fiber tracts occurring in utero. This study may serve as a basis for further investigation of DTI in the fetus, including research into its potential in pathological conditions that impact spinal cord development. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Imagen de Difusión Tensora , Sustancia Blanca , Humanos , Femenino , Embarazo , Imagen de Difusión Tensora/métodos , Estudios Prospectivos , Estudios de Factibilidad , Médula Espinal/diagnóstico por imagen , Médula Espinal/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA