1.
BMC Gastroenterol ; 24(1): 20, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38182996

RESUMEN

BACKGROUND: To investigate the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR), designed and developed by us, for endoscopic gastrointestinal bypass anastomosis. METHODS: Ten experimental pigs were used as model animals. The DSAMAR comprises 10 trapezoidal magnetic units, arranged in a straight line under the constraint of a guide wire. When the desired anastomosis site is reached under the guidance of an endoscope, the catheter pushes the magnetic unit along the guide wire. The linear DSAMAR can be assembled into a circular DSAMAR. Two DSAMARs were inserted, one at the end of the duodenum and the other into the stomach successively. They attracted each other and compressed the wall of the stomach and duodenum to establish gastrointestinal bypass anastomosis. The experimental pigs were euthanized 4 weeks after the operation, and the gastrointestinal bypass anastomosis specimens were obtained. The anastomosis formation was evaluated by the naked eye and histology. RESULTS: Gastrointestinal bypass anastomosis with DSAMARs was successfully performed. The average operation time under an endoscope was 70.30 ± 19.05 min (range: 43-95 min). The DSAMARs were discharged through the anus 10-17 days after surgery. There were no complications such as gastrointestinal bleeding, perforation, anastomotic fistula, and gastrointestinal obstruction during and after the operation. Gastroscopy and gross specimen of the anastomosis showed a well-formed magnetic anastomosis. Histological observation showed good continuity of the serous membrane and the mucosa of magnetic anastomosis. CONCLUSION: The DSAMAR is a safe and feasible device for fashioning gastrointestinal bypass anastomosis in this animal model.


Asunto(s)
Gastroscopía , Estómago , Porcinos , Animales , Anastomosis Quirúrgica , Estómago/cirugía , Duodeno , Fenómenos Magnéticos
2.
J Surg Res ; 276: 283-290, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35405414

RESUMEN

INTRODUCTION: The magnetic compression technique (MCT) is used for the anastomosis of hollow organs by the means of suction between magnets. The MCT is useful for establishing digestive tract anastomoses in rats, for example, end-to-side small intestinal anastomosis and colonic anastomosis. We aim to determine the feasibility of MCT-based esophageal anastomosis in rats. METHODS: Twenty-four Sprague-Dawley albino rats (230-250 g) were randomly divided into an MCT group and a control group (hand-sewn esophageal anastomosis). The time required to construct the anastomosis, postoperative complications, and survival rate was compared between the two groups. At 2 wk postoperatively, the animals were sacrificed to assess the burst pressure and histological features of the anastomoses. RESULTS: The mean anastomosis time was significantly lower for MCT (11.17 ± 1.64 min) than for the hand-sewn technique (27.42 ± 2.23 min; P < 0.001). The survival rate was slightly higher in the MCT group (91.67%) than in the control group (66.67%, P = 0.317). The magnets were discharged from the body after 8.33 ± 0.89 d (range, 7-10 d). No anastomotic leakage or stenosis occurred in the MCT group. Three rats developed anastomotic stenosis and two rats developed anastomotic leakage in the control group. The burst pressures were similar in the two groups. An histological examination showed that compared with the control group, the MCT group had better alignment of the tissue layers and less inflammation. CONCLUSIONS: The MCT is a simple and feasible technique for esophageal anastomosis in rats and has the potential for clinical application.


Asunto(s)
Anastomosis Quirúrgica , Procedimientos Quirúrgicos del Sistema Digestivo , Esófago , Imanes , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/instrumentación , Anastomosis Quirúrgica/métodos , Fuga Anastomótica/etiología , Fuga Anastomótica/prevención & control , Animales , Constricción Patológica/etiología , Procedimientos Quirúrgicos del Sistema Digestivo/efectos adversos , Procedimientos Quirúrgicos del Sistema Digestivo/instrumentación , Procedimientos Quirúrgicos del Sistema Digestivo/métodos , Esófago/cirugía , Fenómenos Magnéticos , Ratas , Ratas Sprague-Dawley , Técnicas de Sutura
3.
Surg Endosc ; 36(11): 8170-8177, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35501603

RESUMEN

BACKGROUND: Being one of the core techniques of magnetic surgery, magnetic compression technique (MCT) has been used for digestive tract anastomosis reconstruction in experimental studies. This study verified the feasibility of gastroenteric anastomosis through natural orifice using MCT in rats. METHODS: The parent and daughter magnets were designed and manufactured for oral and anal insertion in 20 Sprague-Dawley rats. After anesthesia, the parent magnet was inserted into the colon spleen area through the anus, and the daughter magnet was inserted into the stomach through the mouth. Then the two magnets were positioned to attract each other and bind together. The position of the two magnets was monitored using X-ray. The time required for the formation of the anastomosis and expulsion of the magnets were recorded. 2 weeks later, the animal was sacrificed and the anastomotic specimen was obtained which was observed under naked eye and microscope. RESULTS: The gastroenteric anastomosis was successfully performed via natural orifices in 18 out of 20 rats. The mean time to construct the anastomosis was 3.78 ± 0.88 min. X-ray examination showed that the magnets were in the appropriate position in 17 rats. The magnets were excreted in 9.47 ± 1.62 days after surgery. The gross and microscopic examination of the specimen showed that the anastomoses were patent and the mucosa at the anastomotic was smooth. The mean bursting pressure of the anastomosis was 136.94 ± 6.79 mmHg. CONCLUSION: It is feasible to perform gastroenteric anastomosis through natural orifices by MCT.


Asunto(s)
Magnetismo , Imanes , Ratas , Animales , Ratas Sprague-Dawley , Anastomosis Quirúrgica/métodos , Fenómenos Magnéticos
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 45(6): 612-615, 2021 Nov 30.
Artículo en Zh | MEDLINE | ID: mdl-34862772

RESUMEN

Based on the principle of magnetic anastomosis technique, the design of magnetic anastomosis system for endoscopic tissue clamping is proposed. The system includes a semi-ring magnet, a special structure transparent cap and a detachable push rod. With the help of the existing digestive endoscopy and endoscopic tissue gripper, the endoscopic close clamping and anastomosis of the bleeding or perforated tissue can be completed. After the anastomosis, the magnet falls off and is discharged through the digestive tract. Animal experiments showed that the system was easy to use, the fistula was clamped firmly, the magnet was discharged for 7~21 days, and there was no magnet retention and digestive tract obstruction. Further safety verification, optimization of endoscopic operation, the system can be used in clinical trial.


Asunto(s)
Magnetismo , Imanes , Anastomosis Quirúrgica , Animales , Constricción , Endoscopía Gastrointestinal
5.
J Surg Res ; 236: 60-67, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30694780

RESUMEN

BACKGROUND: Magnetic compression anastomosis is a feasible and effective method for bilioenteric anastomosis (BEA) in animal model. The objective of the present study was to report our initial clinical experience in laparoscopically magnetic compression bilioenteric anastomosis (LMC-BEA). METHODS: Patients with obstructive jaundice who were candidates for LMC-BEA were prospectively enrolled from 2013 to 2015. All the procedures were performed laparoscopically. A mother magnet and drainage tube were placed in the proximal bile duct and tightened by a purse suture after dissection of the common bile duct. The drainage tube was introduced into the jejunal lumen at the anastomotic site and guided a daughter magnet to approximate the mother magnet. The two magnets mated at the anastomotic site. All the patients were routinely followed up for magnets discharge till the end of the study. RESULTS: In total, four patients with malignant obstructive jaundice and one patient with benign biliary stricture were included. The median age was 70 y (range, 49-74 y). The median time for LMC-BEA was 12 min (range, 8-15 min). A complete anastomosis was confirmed after a median time of 21 d (range, 5-25 d) postoperatively by cholangiography via drainage tube. The magnets were expulsed around 41 d after surgery (range, 12-47 d) postoperatively. With a median follow-up of 313 d (range, 223-1042 d), no complications associated with magnetic anastomosis was documented, such as bile leakage or anastomotic stricture. CONCLUSIONS: Magnetic compression is a promising alternate method for laparoscopic BEA. Among the five patients undergoing LMC-BEA, no one developed anastomotic complications.


Asunto(s)
Conductos Biliares/cirugía , Ictericia Obstructiva/cirugía , Yeyuno/cirugía , Laparoscopía/métodos , Estomas Quirúrgicos/efectos adversos , Anciano , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/instrumentación , Anastomosis Quirúrgica/métodos , Fuga Anastomótica/epidemiología , Fuga Anastomótica/etiología , Constricción Patológica/epidemiología , Constricción Patológica/etiología , Femenino , Estudios de Seguimiento , Humanos , Laparoscopía/efectos adversos , Laparoscopía/instrumentación , Imanes , Masculino , Persona de Mediana Edad , Tempo Operativo , Datos Preliminares , Estudios Prospectivos , Resultado del Tratamiento
6.
Pediatr Surg Int ; 32(5): 525-8, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27012861

RESUMEN

We describe the treatment of a patient with long-gap esophageal atresia with an upper pouch fistula, mircogastria and minimal distal esophageal remnant. After 4.5 months of feeding via gastrostomy, a proximal fistula was identified by bronchoscopy and a thoracoscopic modified Foker procedure was performed reducing the gap from approximately 7-5 cm over 2 weeks of traction. A second stage to ligate the fistula and suture approximate the proximal and distal esophagus resulted in a gap of 1.5 cm. IRB and FDA approval was then obtained for endoscopic placement of 10-French catheter mounted magnets in the proximal and distal pouches promoting a magnetic compression anastomosis (magnamosis). Magnetic coupling occurred at 4 days and after magnet removal at 13 days an esophagram demonstrated a 10 French channel without leak. Serial endoscopic balloon dilation has allowed drainage of swallowed secretions as the baby learns bottling behavior at home.


Asunto(s)
Atresia Esofágica/cirugía , Esófago/cirugía , Gastropatías/cirugía , Fístula Traqueoesofágica/cirugía , Anastomosis Quirúrgica/métodos , Femenino , Humanos , Lactante , Recién Nacido , Magnetismo , Gastropatías/congénito
7.
J Pediatr Surg ; 59(3): 437-444, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37838619

RESUMEN

INTRODUCTION: Delayed primary repair of esophageal atresia in patients with high-risk physiologic and anatomic comorbidities remains a daunting challenge with an increased risk for peri-operative morbidity and mortality via conventional repair. The Connect-EA device facilitates the endoscopic creation of a secure esophageal anastomosis. This follow-up study reports our long-term outcomes with the novel esophageal magnetic compression anastomosis (EMCA) Connect-EA device for EA repair, as well as lessons learned from the ten first-in-human cases. We propose an algorithm to maximize the advantages of the device for EA repair. METHODS: Under compassionate use approval, from June 2019 to December 2022, ten patients with prohibitive surgical or medical risk factors underwent attempted EMCA with this device. All patients underwent prior gastrostomy, tracheoesophageal fistula ligation (if necessary), and demonstrated pouch apposition prior to EMCA. RESULTS: Successful device deployment and EMCA formation were achieved in nine patients (90%). Mean time to anastomosis formation was 8 days (range 5-14) and the device was retrieved endoscopically in five (56%) cases. At median follow-up of 22 months (range 4-45), seven patients (78%) are tolerating oral nutrition. Balloon dilations (median 4, range 1-11) were performed either prophylactically for radiographic asymptomatic anastomotic narrowing (n = 7, 78%) or to treat clinically-significant anastomotic narrowing (n = 2, 22%) with no ongoing dilations at 3-month follow up post-repair. CONCLUSION: EMCA with the Connect-EA device is a safe and feasible minimally-invasive alterative for EA repair in high-risk surgical patients. Promising post-operative outcomes warrant further Phase I investigation. LEVEL OF EVIDENCE: IV, Case series of novel operative technique without comparison group.


Asunto(s)
Acetatos , Atresia Esofágica , Fístula Traqueoesofágica , Humanos , Atresia Esofágica/cirugía , Ensayos de Uso Compasivo , Estudios de Seguimiento , Anastomosis Quirúrgica/métodos , Resultado del Tratamiento , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
8.
Sci Rep ; 14(1): 10602, 2024 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719935

RESUMEN

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Asunto(s)
Anastomosis Quirúrgica , Estudios de Factibilidad , Animales , Perros , Anastomosis Quirúrgica/métodos , Estómago/cirugía , Imanes , Magnetismo , Cirugía Endoscópica por Orificios Naturales/métodos , Cirugía Endoscópica por Orificios Naturales/instrumentación , Colon/cirugía , Masculino
9.
World J Gastrointest Surg ; 16(5): 1474-1481, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38817291

RESUMEN

Magnetic compression anastomosis is a promising treatment option for patients with complex esophageal atresia; but, at the present time, should not be the first therapeutic option in those cases where the surgeon can perform a primary anastomosis of the two ends of the esophagus with acceptable tension.

10.
Insights Imaging ; 15(1): 128, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38816640

RESUMEN

Obstructions encountered in biliary, gastrointestinal, and urinary tracts are increasing in number due to successful percutaneous and endoscopic organ-saving procedures. Although functional recovery is established to an extent, failure of traversing an obstruction may end up necessitating invasive surgical procedures. Multidisciplinary collaboration may traverse the limitations of each individual approach, therefore creating the perfect intervention for the patient. Magnetic compression anastomosis is a minimally invasive procedure that can provide a great outcome in select cases with biliary, gastrointestinal, or urinary tract obstructions. CRITICAL RELEVANCE STATEMENT: In this article, various applications of magnetic compression anastomosis are reviewed with illustrative cases of esophageal, biliary, colonic, and urinary obstructions that cannot be traversed with a wire. This method will expand the spectrum of interventions performed in the IR unit. KEY POINTS: Magnets can enable wire access beyond an impassable obstruction. Magnets can create anatomical and non-anatomical anastomosis at an occlusion. Magnetic compression anastomosis is a minimally invasive procedure that can provide great outcomes.

11.
Sci Rep ; 14(1): 14265, 2024 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902360

RESUMEN

With the increasing application of magnetic compression anastomosis (MCA) in gastrointestinal anastomosis, we identified an interesting phenomenon that an anastomosis is more prone to stenosis after endoscopic gastrointestinal MCA. We hypothesized that the increase in tissue tension during endoscopic procedures is the cause of anastomotic stenosis. In this study, we investigated the effect of tissue tension on gastroduodenal bypass MCA in Sprague-Dawley (SD) rats. Twenty SD rats were divided into the study group (high-tension group, n = 10) and control group (no tension group, n = 10), wherein the rats underwent complete gastroduodenal bypass magnetic anastomosis under high tension and no tension of the digestive tract, respectively. Anastomotic specimens were obtained 4 weeks after the operation, and anastomotic diameters of the two groups were observed and measured. The histological difference was observed by hematoxylin & eosin and Masson staining. The operation was successfully completed in all rats, and all survived until 4 weeks postoperatively. Anastomotic measurements revealed that the anastomosis diameter was significantly smaller in the study group than in the control group, and there were three cases of severe anastomotic stenosis. Histological observation showed that the amount of collagen fibers in the anastomosis was greater in the study group than in the control group. The results suggest that the high-tension state of the digestive tract is an important factor leading to anastomotic stenosis, and thus, we put forward the Yan-Zhang's Tissue Tension Theory of MCA to explain this phenomenon.


Asunto(s)
Anastomosis Quirúrgica , Ratas Sprague-Dawley , Animales , Anastomosis Quirúrgica/métodos , Ratas , Masculino , Tracto Gastrointestinal/cirugía , Constricción Patológica/cirugía , Magnetismo
12.
Obes Surg ; 34(2): 515-523, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38135738

RESUMEN

PURPOSE: Metabolic surgery remains underutilized for treating type 2 diabetes, as less invasive alternative interventions with improved risk profiles are needed. We conducted a pilot study to evaluate the feasibility of a novel magnetic compression device to create a patent limited caliber side-to-side jejunoileal partial diversion in a nonhuman primate model. MATERIALS AND METHODS: Using an established nonhuman primate model of diet-induced insulin resistance, a magnetic compression device was used to create a side-to-side jejunoileal anastomosis. Primary outcomes evaluated feasibility (e.g., device mating and anastomosis patency) and safety (e.g., device-related complications). Secondary outcomes evaluated the device's ability to produce metabolic changes associated with jejunoileal partial diversion (e.g., homeostatic model assessment of insulin resistance [HOMA-IR] and body weight). RESULTS: Device mating, spontaneous detachment, and excretion occurred in all animals (n = 5). There were no device-related adverse events. Upon completion of the study, ex vivo anastomoses were widely patent with healthy mucosa and no evidence of stricture. At 6 weeks post-device placement, HOMA-IR improved to below baseline values (p < 0.05). Total weight also decreased in a linear fashion (R2 = 0.97) with total weight loss at 6 weeks post-device placement of 14.4% (p < 0.05). CONCLUSION: The use of this novel magnetic compression device to create a limited caliber side-to-side jejunoileal anastomosis is safe and likely feasible in a nonhuman primate model. The observed glucoregulatory and metabolic effects of a partial jejunoileal bypass with this device warrant further investigation to validate the long-term glucometabolic impact of this approach.


Asunto(s)
Diabetes Mellitus Tipo 2 , Resistencia a la Insulina , Obesidad Mórbida , Animales , Macaca mulatta , Proyectos Piloto , Diabetes Mellitus Tipo 2/cirugía , Obesidad Mórbida/cirugía , Anastomosis Quirúrgica , Fenómenos Magnéticos
13.
World J Gastroenterol ; 29(33): 5005-5013, 2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37731993

RESUMEN

BACKGROUND: Although endoscope-assisted magnetic compression anastomosis has already been reported for colonic anastomosis, there is no report on a single-approach operation using the natural orifice. AIM: To design a deformable self-assembled magnetic anastomosis ring (DSAMAR) for colonic anastomosis for use in single-approach operation and evaluate its feasibility and safety through animal experiments. METHODS: The animal model for colonic stenosis was prepared by partial colonic ligation in eight beagles. The magnetic compression anastomosis of their colonic stricture was performed by endoscopically assisted transanal implantation of the DSAMAR. The anastomotic specimen, obtained 2 wk after the operation, was observed by both the naked eye and a light microscope. RESULTS: The DSAMAR was successfully inserted into the proximal end of colon stenosis through the anus. The DSAMAR of seven dogs was successfully transformed into rings, while that of the remaining dog was removed after the first deformation failed. The rings were successfully retransformed after optimization. All animals underwent colonic anastomosis using the DSAMAR. No device-related or procedure-related adverse events were observed. The colostomy specimens of the experimental dogs were obtained 2 wk after the operation. Both gross and histological observations showed good anastomotic healing. CONCLUSION: The DSAMAR is a safe and feasible option for the treatment of colon stenosis. Its specific deformation and self-assembly capability maximize the applicability of the minimally invasive treatment.


Asunto(s)
Endoscopía , Obstrucción Intestinal , Animales , Perros , Constricción Patológica/cirugía , Anastomosis Quirúrgica , Fenómenos Magnéticos
14.
Children (Basel) ; 10(8)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37628327

RESUMEN

Originating in the 1970s, magnetic compression anastomosis (MCA) has lately been revisited with a focus on minimal invasive surgery (MIS). The aim of this report is to reappraise our earlier experience with MCA with the intention of facilitating future MCA advancement. A retrospective review was conducted regarding preclinical experiments and clinical trials at a single institution from 1980 to 1995. The reviewed information was compiled and appraised to generate proposals for future MCA use. The experimental studies, including 250 MCA cases in gastrointestinal and urinary tract animal models, demonstrated the technical versatility of MCA as well as the superior biomechanical characteristics in comparison to hand-sewn anastomoses. Clinical trials encompassed 87 MCA procedures in 86 children, 2 to 10 years of age, involving the following techniques: non-operative esophageal recanalization (n = 15), non-operative ileostomy undiversion (n = 46), Swenson pull-through (n = 10), non-operative urethral recanalization (n = 5), and extravesical ureterocystoneostomy (n = 11). Clinical MCA was found to be successful in over 87% of cases. MCA limitations concerning anastomotic failure and scarring were thought to be mostly due to inadequate magnetic compression. Based on our historic experience, we propose further research on the technical aspects of MCA, along with the biological aspects of anastomotic tissue remodeling. Magnets should be designed and manufactured for a wide spectrum of pediatric surgical indications, particularly in combination with novel MIS techniques.

15.
J Laparoendosc Adv Surg Tech A ; 33(12): 1223-1230, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37603306

RESUMEN

Background: Magnetic compression anastomosis (MCA) is an alternative technique for patients with long-gap esophageal atresia (EA). It allows for preservation of the native esophagus. We aimed to systematically summarize the current literature on MCA in EA. Methods: Studies where neonates with EA were treated with MCA devices were included, while studies on esophageal stenosis were excluded. All clinical studies, including comparative studies, case series, and case reports, were eligible for inclusion. Methodological quality assessment was performed using a validated tool. Results: Twelve studies with a total of 42 patients were included in this review. There was a wide variation among these studies with regard to the time of initiation of MCA (1 day to 7 months), procedure time (13-320 minutes), and magnet characteristics (strength, size, and shape of the magnets used). The time to achieve anastomosis ranged from 1 to 12 days. Stricture at the anastomotic site was reported in almost all the patients, which required multiple endoscopic dilatations (median no. of dilatations/patient = 9.8). Stent placement for refractory stricture was required in 9 (21%) patients, and surgery for stricture was required in 6 (14%) patients. Long-term outcomes included esophageal dysmotility (n = 3) and recurrent pulmonary infections (n = 3) were reported in only four studies. Conclusion: As per the findings of this review, neonates with long-gap EA undergoing MCA would invariably require multiple sittings of endoscopic dilatations (median no. of dilatations/patient = 9.8). Also, there is a wide variation among the included studies in terms of the procedure of MCA. Future studies with a standardized procedure for achieving MCA are needed to determine additional outcomes in this fragile patient population.


Asunto(s)
Atresia Esofágica , Estenosis Esofágica , Recién Nacido , Humanos , Atresia Esofágica/cirugía , Atresia Esofágica/complicaciones , Constricción Patológica/etiología , Estenosis Esofágica/etiología , Estenosis Esofágica/cirugía , Anastomosis Quirúrgica/métodos , Fenómenos Magnéticos , Resultado del Tratamiento , Estudios Retrospectivos
16.
J Pediatr Surg ; 2023 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-37968150

RESUMEN

BACKGROUND: To assess the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR) in the treatment of esophageal stenosis in beagle dogs via transoral access without temporary gastrostomy. METHODS: Experimental esophageal stenosis was created in 10 beagle dogs by partial cervical esophageal ligation. The DSAMAR was inserted into the distal esophagus via the narrow section of the esophagus using a gastroscope. A circular DSAMAR was placed in the proximal esophagus. The magnetic rings on both sides of the experimental stenosis automatically attracted each other. We then recorded the operation time, postoperative complications, anastomotic formation time, and magnetic ring discharge time. The dogs were euthanized 4 weeks postoperatively; subsequently, we obtained the esophageal anastomotic specimens and observed the anastomotic formation via the naked eye and by light microscopy. RESULTS: Our esophageal stenosis model produced reproducible stenoses in all dogs, which was confirmed via endoscopy and esophagography. DSAMAR was successfully implanted in all experimental animals under endoscopic and X-ray monitoring, and all linear DSAMARs were successfully transformed into rings. The magnets at both ends of the esophageal stenosis were automatically attracted. All animals survived until euthanasia. No complications, including esophageal perforation, bleeding, and gastrointestinal obstruction, were noted during the perioperative period. The mean operation time of endoscopic magnetic anastomosis was 15.6 ± 2.41 (range, 12-19) min. The mean esophageal anastomotic formation time was 8.8 ± 1.03 (range, 7-10) days, and the mean expulsion time of DSAMAR was 13.94 ± 2.88 (range, 10-19) days. Gastroscopy and esophagography were performed at 4 weeks postoperatively; the esophageal patency was good. Macroscopic observation of the esophageal anastomotic specimens revealed that the esophageal mucosal layer of the anastomosis had good continuity and the anastomosis was smooth. CONCLUSION: DSAMAR is a feasible option for magnetic recanalization of esophageal stricture via transoral access without temporary gastrostomy.

17.
J Pediatr Surg ; 58(8): 1489-1493, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36307298

RESUMEN

BACKGROUND: We designed a new Esophageal Magnetic Anastomosis Device (EMAD) for thoracoscopic repair of esophageal atresia (EA) with tracheoesophageal fistula (TEF) without the need of handheld suturing or additional gastrostomy. METHODS: Synthetic EA-TEF model: Spherical and tubular shaped rubber balloons and a term infant sized plastic doll were used. Medical students (n = 10) and surgical trainees (n = 10) were asked to perform thoracoscopic repair of an "EA" with a hand sutured anastomosis (HA) and with the EMAD. Euthanized animal model: The esophagus in 5 piglets (3-4 kg) was dissected and a thoracoscopic esophageal magnetic anastomosis (EMA) was performed. Bursting pressure (BP) and pulling force (PF): HA and EMA were created on ex vivo New Zealand white rabbit (2.5-3 kg) esophagi (n = 25 in each test series). BP and PF were measured and compared against each other. RESULTS: Medical students were unable to complete HA, but were successful with the EMAD in 11.1 ± 2.78 min. Surgical trainees completed EMA in 4.6 ± 2.06 min vs. HA 30.8 ± 4.29 min (p<0.001). The BP following a HA (14.1 ± 3.32 cmH2O) was close to the physiological intraluminal pressure reported in a neonatal esophagus (around 20 cmH2O), whereas the BP with the EMAD was extremely high (>90 cmH2O) (p<0.001). The PF of an EMA (1.8 ± 0.30 N) was closer to the safety limits of anastomotic tension reported in the literature (i.e. 0.75 N) compared with the HA (3.6 ± 0.43 N) (p<0.0001). CONCLUSION: The EMAD could simplify, shorten, and potentially improve the outcome of thoracoscopic repair for EA with TEF in the future. A high BS and a relative low PF following EMAD application may lower the risk of postoperative complications such as esophageal leakage and stricture formation.


Asunto(s)
Atresia Esofágica , Fístula Traqueoesofágica , Porcinos , Animales , Conejos , Fístula Traqueoesofágica/cirugía , Fístula Traqueoesofágica/complicaciones , Atresia Esofágica/cirugía , Atresia Esofágica/complicaciones , Prueba de Estudio Conceptual , Toracoscopía/educación , Anastomosis Quirúrgica , Fenómenos Magnéticos , Resultado del Tratamiento , Estudios Retrospectivos
18.
J Pediatr Surg ; 58(3): 405-411, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36150933

RESUMEN

BACKGROUND: Aim of study is to report our preliminary experience with magnetic anastomosis (magnamosis) treating long-gap esophageal atresia (LGEA), the most challenging condition of esophageal atresia continuum. Magnamosis has been reported in 20 patients worldwide as an innovative and marginally invasive option. METHODS: Prospective evaluation of all LGEA patients treated with magnamosis was performed (study registration number: 2535/2021). Main outcomes considered were demographic and surgical features, postoperative complications and feeding within 6-month of follow-up. RESULTS: Between June 2020 and January 2021, 5 LGEA patients (Type A, Gross classification) were treated. Median preoperative gap was 5 vertebral bodies. Magnetic bullets were placed at an average age of 81 days of life, leading to successful magnamosis in all cases: 4 infants had primary magnetic repair (one after thoracoscopic mobilization of the pouches), 1 patient had a delayed magnamosis after Foker's procedure. Esophageal anastomosis was achieved after an average of 8 days. No anastomotic leak was found. All patients developed anastomotic stenosis at 6-month follow-up, requiring a mean of 6 dilations each. Full oral feeding was achieved in 3 patients, while 2 were still on oral-gastrostomy feeding. One patient experienced small esophageal perforation after dilation (3 months after magnamosis), distal to the anastomotic stricture and subsequently developed oral aversion. CONCLUSIONS: Our preliminary results suggest magnamosis a safe and effective minimally invasive option in patients with LGEA. Absence of postoperative esophageal leaks may represent a major advantage of magnamosis over conventional surgery, although possible high rate of esophageal stenosis should be further evaluated. LEVELS OF EVIDENCE: IV (Case series with no comparison group).


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo , Atresia Esofágica , Estenosis Esofágica , Lactante , Humanos , Atresia Esofágica/cirugía , Atresia Esofágica/complicaciones , Estenosis Esofágica/etiología , Procedimientos Quirúrgicos del Sistema Digestivo/efectos adversos , Magnetismo , Anastomosis Quirúrgica/métodos , Resultado del Tratamiento
19.
World J Gastrointest Endosc ; 15(12): 745-750, 2023 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-38187917

RESUMEN

BACKGROUND: Endoscopic balloon dilation is a minimally invasive treatment for colorectal stenosis. Magnetic compression anastomosis can be applied against gastrointestinal anastomosis. When combined with endoscopy, it offers a unique approach to the recanalization of colorectal stenosis. CASE SUMMARY: We have reported here the case of a 53-year-old female patient who underwent a descending colostomy due to sigmoid obstruction. Postoperative fistula restoration was not possible in her due to sigmoid stenosis. Accordingly, endoscopic-assisted magnetic compression anastomosis for sigmoid stenosis was performed, and the sigmoid stenosis was recanalized 15 d after the surgery. Subsequently, a reduction colostomy was successfully performed after 10 d. CONCLUSION: This case report proposes a novel minimally invasive treatment approach for colorectal stenosis.

20.
J Pediatr Surg ; 57(12): 810-818, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35760639

RESUMEN

INTRODUCTION: Preservation of native esophagus is a tenet of esophageal atresia (EA) repair. However, techniques for delayed primary anastomosis are severely limited for surgically and medically complex patients at high-risk for operative repair. We report our initial experience with the novel application of the Connect-EA, an esophageal magnetic compression anastomosis device, for salvage of primary repair in 2 high-risk complex EA patients. Compassionate use was approved by the FDA and treating institutions. OPERATIVE TECHNIQUE: Two approaches using the Connect-EA are described - a totally endoscopic approach and a novel hybrid operative approach. To our knowledge, this is the first successful use of a hybrid operative approach with an esophageal magnetic compression device. OUTCOMES: Salvage of delayed primary anastomosis was successful in both patients. The totally endoscopic approach significantly reduced operative time and avoided repeat high-risk operation. The hybrid operative approach salvaged delayed primary anastomosis and avoided cervical esophagostomy. CONCLUSION: The Connect-EA is a novel intervention to achieve delayed primary esophageal repair in complex EA patients with high-risk tissue characteristics and multi-system comorbidities that limit operative repair. We propose a clinical algorithm for use of the totally endoscopic approach and hybrid operative approach for use of the Connect-EA in high-risk complex EA patients.


Asunto(s)
Atresia Esofágica , Esofagoplastia , Fístula Traqueoesofágica , Humanos , Atresia Esofágica/cirugía , Resultado del Tratamiento , Esofagoplastia/métodos , Anastomosis Quirúrgica/métodos , Fístula Traqueoesofágica/cirugía
SELECCIÓN DE REFERENCIAS