Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Minim Invasive Ther Allied Technol ; 33(2): 120-128, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38146672

RESUMEN

The mechanical properties of the stent graft are important factors influencing the outcome of TEVAR treatment and the occurrence of postoperative complications. The aim of this study is to improve and design a mechanical performance testing equipment for thoracic aortic stent grafts. The mechanical performance testing equipment consists of a radial force testing equipment of the stent graft designed by the wire compression grip method and a dynamic straightening force testing device with stable and controllable test conditions and continuously variable test angles. By constructing the testing equipment to physically measure the stent specimen, the experimental results reflect the trend of change and the simulation results are basically consistent, i.e. the mechanical properties of the thoracic aortic stent designed in this study is feasible and the measured data are valid. The testing equipment can provide the basis and reference direction for the quality testing of stent graft products, optimisation of mechanical properties of stent grafts and R&D innovation.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Diseño de Prótesis , Aorta Torácica/cirugía , Stents , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento
2.
Artículo en Inglés | MEDLINE | ID: mdl-37640252

RESUMEN

OBJECTIVE: In this study, the long term durability of fenestrations after in situ fenestration (ISF) of five commercial thoracic aortic stent grafts was evaluated in an in vitro experiment after a simulated 10 year period. METHODS: Five different thoracic aortic stent grafts (Relay, Valiant, Hercules, TAG, and Ankura, with a diameter of 34 mm) received both needle and laser ISF in vitro. A Viabahn (11 × 50 mm) was released in each fenestration as a bridging stent graft. Long term fatigue tests (simulating 10 years) of each of the fenestrated stent grafts were then conducted in a flow fatigue test system. The area, shape, margin, and the long and short axis of all the fenestrations were evaluated with light microscopy before and after the fatigue test. The leakage from the fenestration junction before and after the long term fatigue was also measured. RESULTS: The experimental results showed no obvious difference between needle and laser fenestrations. The long axes of all the fenestrations remained unchanged, while the short axes increased after the fatigue test, which was significant in Relay, Valiant, and Hercules polyethylene terephthalate stent grafts. The shape scores of fenestrations improved after the fatigue test in Valiant and Hercules, remained unchanged in Relay and Ankura, and worsened in the TAG. After the fatigue cycling, the average leakage from the fenestration junction decreased in all the stent grafts, and the Ankura had the maximum decline rate. CONCLUSION: The ISF technique was durable over a simulated 10 year period. The fenestrations were positively remodelled to be more circular, and the leakage from the junction decreased after long term fatigue testing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA