Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 358
Filtrar
Más filtros

Intervalo de año de publicación
1.
Nephrology (Carlton) ; 29(4): 214-221, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37986674

RESUMEN

AIM: Circulating blood volume (BV) during exercise changes depending on the intensity and duration, and post-exercise hypotension is observed after continuous exercise. We investigated the safety and efficacy of both interval and continuous IDE at anaerobic threshold (AT) levels with respect to hemodynamic stability and dialysis efficiency. METHODS: In this crossover randomized controlled trial, 16 patients on haemodialysis were subjected to three trial arms, including non-IDE, interval-IDE, and continuous-IDE arms. Systolic blood pressure (SBP), BV, and ultraviolet absorbance - an indicator of dialysis efficiency - were continuously measured, and each change was compared between the three arms by two-way analysis of variance. RESULTS: Continuous IDE decreased SBP from post-exercise to the end of dialysis compared with baseline (pre 142.8 ± 19.0 vs. post 127.5 ± 24.5 mmHg, p = .02), whereas interval IDE maintained better SBP levels post-exercise (pre 139.9 ± 17.1 vs. post 140.1 ± 15.8 mmHg, p = 1.0) than continuous IDE (non-IDE 133.2 ± 19.9 vs. interval 140.1 ± 15.8 vs. continuous 127.5 ± 24.5 mmHg, p = .04). Moreover, interval IDE caused less tiredness and few symptoms (p < .05), despite reaching higher intensity than continuous IDE (p = .001). The BV of each IDE arm decreased during exercise and recovered post-exercise to the same level as non-IDE. Ultraviolet absorbance was not different between each arm (p = .16). CONCLUSION: AT-level interval IDE maintains better hemodynamic stability from post-exercise to the end of dialysis and may represent a novel approach that can be effectively performed with fewer symptoms.


Asunto(s)
Hemodinámica , Diálisis Renal , Humanos , Diálisis Renal/efectos adversos , Presión Sanguínea/fisiología , Volumen Sanguíneo/fisiología , Ejercicio Físico/fisiología
2.
Eur J Appl Physiol ; 124(10): 2881-2891, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38703192

RESUMEN

PURPOSE: Moderate-intensity aerobic exercise is safe and beneficial in atrial fibrillation (AF) and coronary heart disease (CHD). Irregular or rapid heart rates (HR) in AF and other heart conditions create a challenge to using HR to monitor exercise intensity. The purpose of this study was to assess the potential of breathing frequency (BF) to monitor exercise intensity in people with AF and CHD without AF. METHODS: This observational study included 30 AF participants (19 Male, 70.7 ± 8.7 yrs) and 67 non-AF CHD participants (38 Male, 56.9 ± 11.4 yrs). All performed an incremental maximal exercise test with pulmonary gas exchange. RESULTS: Peak aerobic power in AF ( V ˙ O2peak; 17.8 ± 5.0 ml.kg-1.min-1) was lower than in CHD (26.7 ml.kg-1.min-1) (p < .001). BF responses in AF and CHD were similar (BF peak: AF 34.6 ± 5.4 and CHD 36.5 ± 5.0 breaths.min-1; p = .106); at the 1st ventilatory threshold (BF@VT-1: AF 23.2 ± 4.6; CHD 22.4 ± 4.6 breaths.min-1; p = .240). % V ˙ O2peak at VT-1 were similar in AF and CHD (AF: 59%; CHD: 57%; p = .656). CONCLUSION: With the use of wearable technologies on the rise, that now include BF, this first study provides an encouraging potential for BF to be used in AF and CHD. As the supporting data are based on incremental ramp protocol results, further research is required to assess BF validity to manage exercise intensity during longer bouts of exercise.


Asunto(s)
Fibrilación Atrial , Enfermedad Coronaria , Frecuencia Cardíaca , Humanos , Masculino , Fibrilación Atrial/fisiopatología , Femenino , Frecuencia Cardíaca/fisiología , Persona de Mediana Edad , Anciano , Enfermedad Coronaria/fisiopatología , Ejercicio Físico/fisiología , Frecuencia Respiratoria/fisiología , Prueba de Esfuerzo/métodos , Consumo de Oxígeno/fisiología , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación
3.
Eur J Appl Physiol ; 124(7): 2111-2122, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38421429

RESUMEN

PURPOSE: This study aimed to compare the effects of acute and multi-day low-dose sodium bicarbonate (SB) intake on high-intensity endurance exercise performance. METHODS: In a randomized, double-blind, cross-over design, twelve recreational male cyclists (age: 31.17 ± 4.91 years; V ˙ O2peak: 47.98 ± 7.68 ml·kg-1·min-1) completed three endurance performance tests following acute SB (ASB, 0.2 g·kg-1 SB), multi-day SB (MSB, 0.2 g·kg-1·day-1 SB for four days), and placebo (PLA) intake. The high-intensity endurance performance was assessed with a cycling exercise test, wherein participants cycled on a bicycle ergometer at 95% of the predetermined anaerobic threshold for 30 min, followed by a time-to-exhaustion test at 110% of the anaerobic threshold. Data were analyzed using one-way and two-way repeated-measures ANOVA. RESULTS: Significant main effects of supplementation protocol were evident in pre-exercise bicarbonate concentrations (F = 27.93; p < 0.01; partial eta squared (η2) = 0.72; false discovery rate (FDR)-adjusted p value = 0.001). Prior to performance test, blood bicarbonate concentrations were significantly higher in MSB (25.78 ± 1.63 mmol·L-1 [95% CI 26.55-28.44] (p < 0.001; FDR-adjusted p value = 0.001)) and ASB (27.49 ± 1.49 mmol·L-1 [95% CI 24.75-26.81] (p < 0.001; FDR-adjusted p value = 0.007)) compared to PLA (23.75 ± 1.40 mmol·L-1 [95% CI 22.86 to 24.64]). Time-to-exhaustion increased in MSB (54.27 ± 9.20 min [95% CI 48.43-60.12]) compared to PLA (49.75 ± 10.80 min [95% CI 42.89-56.62]) (p = 0.048); however, this increase in MSB did not reach the significance threshold of 1% FDR (FDR-adjusted p value = 0.040). No significant difference was noted in exhaustion times between ASB (51.15 ± 8.39 min [95% CI 45.82-56.48]) and PLA (p > 0.05). CONCLUSION: Both acute and multi-day administration of low-dose SB improves buffering system in cyclists; nevertheless, neither intervention demonstrates sufficient efficacy in enhancing high-intensity endurance performance.


Asunto(s)
Ciclismo , Resistencia Física , Bicarbonato de Sodio , Humanos , Masculino , Adulto , Bicarbonato de Sodio/administración & dosificación , Bicarbonato de Sodio/farmacología , Ciclismo/fisiología , Resistencia Física/efectos de los fármacos , Resistencia Física/fisiología , Rendimiento Atlético/fisiología , Método Doble Ciego , Estudios Cruzados , Umbral Anaerobio/efectos de los fármacos , Suplementos Dietéticos , Consumo de Oxígeno/efectos de los fármacos
4.
Eur J Appl Physiol ; 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38849689

RESUMEN

PURPOSE: To evaluate the agreement between the two Gas Exchange Thresholds (GETs = GET1 and GET2), identified by the conventional V-Slope method, and two Respiratory Frequency Thresholds (fRTs = fRT1 and fRT2) obtained from a novel, low-cost, and simple method of breakpoint determination. METHODS: Fifty middle-aged males (age: 50-58 years; V ˙ o2peak: 37.5 ± 8.6 mL·Kg-1·min-1), either healthy or with chronic illnesses, underwent an incremental cycle exercise test to determine maximal oxygen uptake ( V ˙ o2max/ V ˙ o2peak), GETs and fRTs. RESULTS: There were no statistical differences [P > 0.05; ES: 0.17 to 0.32, small] between absolute and relative (56-60% V ˙ o2peak) oxygen uptake ( V ˙ o2) values at GET1 with those obtained at fRT1, nor between V ˙ o2 values at GET2 with those at fRT2 (76-78% V ˙ o2peak). Heart rate (HR) at fRT1, and V ˙ o2 and HR at fRT2 showed very large correlations (r = 0.75-0.82; P < 0.001) and acceptable precision (SEE < 7-9%) in determination of their corresponding values at GET1 and GET2. The precision in the estimation of V ˙ o2 at GET1 from fRT1 was moderate (SEE = 15%), while those of power output at GET1 (SEE = 23%) and GET2 (SEE = 12%) from their corresponding fRTs values were very poor to moderate. CONCLUSION: HR at fRT1 and V ˙ o2 and HR at fRT2, determined using a new objective and portable approach, may potentially serve as viable predictors of their respective GETs. This method may offer a simplified, cost-effective, and field-based approach for determining exercise threshold intensities during graded exercise.

5.
Am J Physiol Heart Circ Physiol ; 325(4): H656-H664, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37505473

RESUMEN

Stringer et al. [J Appl Physiol (1985) 82: 908-912, 1997] developed a method from invasive data to estimate cardiac output during incremental exercise testing based on Fick's principle. The authors proposed that the arterio-mixed venous oxygen content difference increases linearly with percentage of maximal O2 consumption. We hypothesized an S-shaped pattern in the published data and calculated the inflection point of this curve and of the standard resting oxygen dissociation curve. Using a partial F test, we compared the linear model with a third-order polynomial model, which showed a better fit to the data [F(2,101) = 9.5, P < 0.001]. This finding was reproduced in a dataset published by Åstrand et al. in 1964 [F(2, 122) = 10.6, P < 0.001]. The inflection point of the curve coincided with the lactate acidosis threshold [first ventilatory threshold (VT1)] as measured by Stringer et al. (VT1 at 50% and inflection point at 56% [95% CI, 52.9 to 60.7] of maximal O2 consumption). The inflection point of the standard resting oxygen dissociation curve was calculated at a partial pressure of 21.5 mmHg and a saturation of 36%, matching the "critical capillary Po2" concept of Stringer et al. (21.2 mmHg). We conclude that the arterio-mixed venous oxygen content difference increases in an S-shaped manner with percentage of maximal oxygen consumption and that the inflection point of this curve may correspond to VT1 and that of the in vivo oxygen dissociation curve. Further research is needed to confirm these findings and improve the method.NEW & NOTEWORTHY In 1997, Stringer, Hansen, and Wasserman developed a method for estimating cardiac output during incremental exercise testing. They observed that the arterio-mixed venous oxygen content difference increases linearly with the percentage of maximal O2 consumption. This increase may be better modelled by an S-shaped function, the inflection point of which may be related to the first ventilatory threshold and the inflection point of the oxygen dissociation curve. This finding may help to improve the method.


Asunto(s)
Gasto Cardíaco , Ejercicio Físico , Consumo de Oxígeno , Humanos , Pruebas de Función Respiratoria , Umbral Anaerobio , Estudios Retrospectivos
6.
J Muscle Res Cell Motil ; 44(2): 115-122, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36326961

RESUMEN

Half-marathon (HM) is a running sport of increasing popularity in both sexes and in all age groups worldwide during the last years. Many studies have examined several aspects of HM, such as performance and participation trends, sex and age differences, physiological correlates, and training; however, no comprehensive review has ever been contacted to summarize the recently accumulated knowledge. Therefore, the aim of the present study was to review all previous research in this sport, focusing on participation and performance aspects. It was shown that HM runners had similar anthropometric and physiological characteristics as full-marathon runners which should be attributed to the affinity of these two races in terms of metabolic demands. Performance in HM was related with superior scores in aerobic capacity (maximal oxygen uptake, anaerobic threshold and running economy) and training characteristics (sport experience, weekly distance, training speed, frequency of sessions and long single endurance run distance), and lower scores in adiposity-related scores (e.g. body mass, body mass index, body fat percentage and skinfold thickness). Considering the popularity of HM race and the lack of many original studies (compared to FM race), this is an exciting field for scientific research with a large potential for practical applications, since the majority of HM runners are amateur runners in need of sex-, age- and performance-tailored exercise prescription.


Asunto(s)
Carrera de Maratón , Carrera , Masculino , Femenino , Humanos , Carrera/fisiología
7.
Br J Anaesth ; 130(2): 122-132, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36529576

RESUMEN

Epidemiological evidence has highlighted a strong relationship between cardiorespiratory fitness and surgical outcomes; specifically, fitter patients possess heightened resilience to withstand the surgical stress response. This narrative review draws on exercise and surgical physiology research to discuss and hypothesise the potential mechanisms by which higher fitness affords perioperative benefit. A higher fitness, as indicated by higher peak rate of oxygen consumption and ability to sustain metabolic homeostasis (i.e. higher anaerobic threshold) is beneficial postoperatively when metabolic demands are increased. However, the associated adaptations with higher fitness, and the related participation in regular exercise or physical activity, might also underpin the observed perioperative benefit through a process of hormesis, a protective adaptive response to the moderate and intermittent stress of exercise. Potential mediators discussed include greater antioxidant capacity, metabolic flexibility, glycaemic control, lean body mass, and improved mood.


Asunto(s)
Capacidad Cardiovascular , Humanos , Ejercicio Físico/fisiología , Terapia por Ejercicio , Umbral Anaerobio , Consumo de Oxígeno/fisiología , Aptitud Física/fisiología , Prueba de Esfuerzo
8.
Heart Vessels ; 38(11): 1344-1355, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37493799

RESUMEN

This retrospective observational study aimed to examine the relationships of maximum walking speed (MWS) with peak oxygen uptake (peak VO2) and anaerobic threshold (AT) obtained by cardiopulmonary exercise testing (CPX) in patients with heart failure. The study participants were 104 consecutive men aged ≥ 20 years who had been hospitalized or had undergone outpatient care at our hospital for heart failure between February 2019 and January 2023. MWS was measured in a 5-m section with a 1-m run-up before and after the course. Multivariable analysis was used to examine the association between MWS and peak VO2 and AT by CPX. The Pearson correlation coefficient showed that MWS was positively correlated with percent-predicted peak VO2 and percent-predicted AT (r = 0.463, p < 0.001; and r = 0.485, p < 0.001, respectively). In the multiple linear regression analysis employing percent-predicted peak VO2 and percent-predicted AT as the objective variables, only MWS demonstrated a significant positive correlation (standardized ß: 0.471, p < 0.001 and 0.362, p < 0.001, respectively). Multiple logistic regression analyses, using an 80% cutoff in percent-predicted peak VO2 and AT, revealed that only MWS was identified as a significant factor in both cases (odds ratio [OR]: 1.239, 95% confidence interval [CI]: 1.071-1.432, p = 0.004 and OR: 1.469, 95% CI: 1.194-1.807, p < 0.001, respectively). MWS was correlated with peak VO2 and AT in male patients with heart failure. The MWS measurement as a screening test for exercise tolerance may provide a simple means of estimating peak VO2 and AT in heart failure patients.


Asunto(s)
Umbral Anaerobio , Insuficiencia Cardíaca , Humanos , Masculino , Velocidad al Caminar , Consumo de Oxígeno , Insuficiencia Cardíaca/diagnóstico , Prueba de Esfuerzo , Oxígeno
9.
Arch Phys Med Rehabil ; 104(10): 1612-1619, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37172675

RESUMEN

OBJECTIVE: To provide reference values of cardiorespiratory fitness for individuals post-stroke in clinical rehabilitation and to gain insight in characteristics related to cardiorespiratory fitness post stroke. DESIGN: A retrospective cohort study. Reference equations of cardiopulmonary fitness corrected for age and sex for the fifth, 25th, 50th, 75th, and 95th percentile were constructed with quantile regression analysis. The relation between patient characteristics and cardiorespiratory fitness was determined by linear regression analyses adjusted for sex and age. Multivariate regression models of cardiorespiratory fitness were constructed. SETTING: Clinical rehabilitation center. PARTICIPANTS: Individuals post-stroke who performed a cardiopulmonary exercise test as part of clinical rehabilitation between July 2015 and May 2021 (N=405). MAIN OUTCOME MEASURES: Cardiorespiratory fitness in terms of peak oxygen uptake (V˙O2peak) and oxygen uptake at ventilatory threshold (V˙O2-VT). RESULTS: References equations for cardiorespiratory fitness stratified by sex and age were provided based on 405 individuals post-stroke. Median V˙O2peak was 17.8[range 8.4-39.6] mL/kg/min and median V˙O2-VT was 9.7[range 5.9-26.6] mL/kg/min. Cardiorespiratory fitness was lower in individuals who were older, women, using beta-blocker medication, and in individuals with a higher body mass index and lower motor ability. CONCLUSIONS: Population specific reference values of cardiorespiratory fitness for individuals post-stroke corrected for age and sex were presented. These can give individuals post-stroke and health care providers insight in their cardiorespiratory fitness compared with their peers. Furthermore, they can be used to determine the potential necessity for cardiorespiratory fitness training as part of the rehabilitation program for an individual post-stroke to enhance their fitness, functioning and health. Especially, individuals post-stroke with more mobility limitations and beta-blocker use are at a higher risk of low cardiorespiratory fitness.


Asunto(s)
Capacidad Cardiovascular , Accidente Cerebrovascular , Humanos , Femenino , Estudios Retrospectivos , Valores de Referencia , Consumo de Oxígeno , Accidente Cerebrovascular/complicaciones , Prueba de Esfuerzo , Oxígeno
10.
Langenbecks Arch Surg ; 409(1): 7, 2023 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-38093118

RESUMEN

PURPOSE: This study aimed to investigate the association of effort-independent variables derived from the preoperative cardiopulmonary exercise test (CPET) with 30-day postoperative complications after elective colorectal surgery. METHODS: A multicenter (n=4) retrospective explorative study was performed using data of patients who completed a preoperative CPET and underwent elective colorectal surgery. The preoperative slope of the relation between minute ventilation and carbon dioxide production (VE/VCO2-slope) and the oxygen uptake efficiency slope (OUES), as well as 30-day postoperative complications, were assessed. Multivariable logistic regression analyses and receiver operating characteristic (ROC) curves were used to investigate the prognostic value of the relationship between these preoperative CPET-derived effort-independent variables and postoperative complications. RESULTS: Data from 102 patients (60.1% males) with a median age of 72.0 (interquartile range 67.8-77.4) years were analyzed. Forty-four patients (43.1%) had one or more postoperative complications (of which 52.3% general and 77.3% surgical complications). Merely 10 (9.8%) patients had a general complication only. In multivariate analysis adjusted for surgical approach (open versus minimally invasive surgery), the VE/VCO2-slope (odds ratio (OR) 1.08, confidence interval (CI) 1.02-1.16) and OUES (OR 0.94, CI 0.89-1.00) were statistically significant associated with the occurrence of 30-day postoperative complications. CONCLUSION: The effort-independent VE/VCO2-slope and OUES might be used to assist in future preoperative risk assessment and could especially be of added value in patients who are unable or unwilling to deliver a maximal cardiorespiratory effort. Future research should reveal the predictive value of these variables individually and/or in combination with other prognostic (CPET-derived) variables for postoperative complications. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT05331196.


Asunto(s)
Cirugía Colorrectal , Insuficiencia Cardíaca , Masculino , Humanos , Anciano , Femenino , Prueba de Esfuerzo , Estudios Retrospectivos , Consumo de Oxígeno , Pronóstico , Complicaciones Posoperatorias/epidemiología
11.
Biol Sport ; 40(3): 657-664, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37398957

RESUMEN

Stryd is a foot pod that reliably estimates running power. Our objectives were to examine the efficacy of the website-generated Stryd critical power (CPSTRYD) as a meaningful parameter for runners. 20 runners performed their regular training while wearing Stryd for a minimum of 6 weeks to generate CPSTRYD. Runners completed laboratory graded exercise testing, and outdoor 1500 m and 5000 m time trails. CPSTRYD was most similar to the second ventilatory threshold (VT2) or the onset of blood lactate accumulation (OBLA) and is highly predictive of running performance. Stryd ground contact time (GCT) was a predictor of performance when comparing runners at the same submaximal treadmill speed. CPSTRYD generated from outdoor running is equivalent to that calculated using an established CP model. However, variance between different methods of CP estimation must be a consideration for runners and coaches. Stryd offers meaningful data for runners including a realistic estimate of CP.

12.
J Muscle Res Cell Motil ; 43(1): 35-44, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35084659

RESUMEN

Acute metabolic and molecular response to exercise may vary according to exercise's intensity and duration. However, there is a lack regarding specific tissue alterations after acute exercise with aerobic or anaerobic predominance. The present study investigated the effects of acute exercise performed at different intensities, but with equal total load on molecular and physiological responses in swimming rats. Sixty male rats were divided into a control group and five groups performing an acute bout of swimming exercise at different intensities (80, 90, 100, 110 and 120% of anaerobic threshold [AnT]). The exercise duration of each group was balanced so all groups performed at the same total load. Gene expression (HIF-1α, PGC-1α, MCT1 and MCT4 mRNA), blood biomarkers and tissue glycogen depletion were analyzed after the exercise session. ANOVA One-Way was used to indicate statistical mean differences considering 5% significance level. Blood lactate concentration was the only biomarker sensitive to acute exercise, with a significant increase in rats exercised above AnT intensities (p < 0.000). Glycogen stores of gluteus muscle were significantly reduced in all exercised animals in comparison to control group (p = 0.02). Hepatic tissue presented significant reduction in glycogen in animals exercised above AnT (p = 0.000, as well as reduced HIF-1α mRNA and increased MCT1 mRNA, especially at the highest intensity (p = 0.002). Physiological parameters did not alter amongst groups for most tissues. Our results indicate the hepatic tissue alterations (glycogen stores and gene expressions) in response to different exercise intensities of exercise, even with the total load matched.


Asunto(s)
Condicionamiento Físico Animal , Natación , Umbral Anaerobio , Animales , Glucógeno/metabolismo , Masculino , Músculo Esquelético/metabolismo , ARN Mensajero/metabolismo , Ratas , Natación/fisiología
13.
Colorectal Dis ; 24(1): 93-101, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34612581

RESUMEN

AIM: Although cardiopulmonary exercise testing (CPET) is considered the gold standard, a preoperative abdominal CT scan might also provide information concerning preoperative aerobic fitness for risk assessment. This study aimed to investigate the association between preoperative CT-scan-derived body composition variables and preoperative CPET variables of aerobic fitness in colorectal surgery. METHOD: In this retrospective cohort study, CT images at level L3 were analysed for skeletal muscle mass, skeletal muscle radiation attenuation, visceral adipose tissue (VAT) mass and subcutaneous adipose tissue mass. Regression analyses were performed to investigate the relation between CT-scan-derived body composition variables, CPET-derived aerobic fitness and other preoperative patient-related variables. Logistic regression analysis was performed to predict a preoperative anaerobic threshold (AT) ≤ 11.1 ml/kg/min as cut-off for having a high risk for postoperative complications. RESULTS: Data from 78 patients (45 men; mean [SD] age 74.5 [6.4 years]) were analysed. A correlation coefficient of 0.55 was observed between absolute AT and skeletal muscle mass index. Absolute AT (R2 of 51.1%) was lower in patients with a lower skeletal muscle mass index, together with higher age, lower body mass and higher American Society of Anesthesiologists (ASA) score. Higher ASA score (odds ratio 5.64; P = 0.033) and higher VAT mass (odds ratio 1.02; P = 0.036) were associated with an increased risk of an AT ≤ 11.1 ml/kg/min. CONCLUSION: Body composition variables from the preoperative CT scan were moderately associated with preoperative CPET-derived aerobic fitness. Higher ASA score and higher VAT mass were associated with an increased risk of an AT ≤ 11.1 ml/kg/min.


Asunto(s)
Cirugía Colorrectal , Procedimientos Quirúrgicos del Sistema Digestivo , Anciano , Composición Corporal , Prueba de Esfuerzo/métodos , Humanos , Masculino , Músculo Esquelético/diagnóstico por imagen , Estudios Retrospectivos
14.
Eur J Appl Physiol ; 122(10): 2233-2241, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35829751

RESUMEN

PURPOSE: Exercise prescription based on a population-specific physiological response can help ensure safe and effective physical interventions. However, as a facile approach for exercise prescription in hemodialysis population that is based on their exercise capacity has not yet been established, the aim of our study was to develop a unique prediction formula for peak heart rate (HR) that can be used in this population. METHODS: This cross-sectional study measured physical function and HR at peak exercise and anaerobic threshold (AT) during cardiopulmonary exercise tests in 126 individuals. Participants were randomly assigned to the development group (n = 78), whose data were used to calculate the prediction equation, or the validation group (n = 48). RESULTS: The HR reserve in this population was significantly lower (0.44 ± 0.20%) and there was a large discrepancy between conventional age-predicted maximal HR and measured peak-HR values (R = 0.36). The average of the ratio between HR at AT point and peak HR was 85% (95% CI, 83.5%-86.4%). The peak-HR prediction equation was based on resting HR, presence of diabetes, physical dysfunction (gait speed < 1.0 m/s), and hypoalbuminemia (< 3.5 g/dL). It showed high prediction accuracy (R2 [95%CI] = 0.71 [0.70-0.71]) with similar correlation coefficients between the development and validation groups (R = 0.82). CONCLUSION: Aerobic exercise based on estimated peak HR < 85% obtained from the equation in this study may enable safe and effective physical intervention in this population.


Asunto(s)
Prueba de Esfuerzo , Consumo de Oxígeno , Estudios Transversales , Frecuencia Cardíaca/fisiología , Humanos , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Diálisis Renal
15.
Sensors (Basel) ; 22(7)2022 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-35408296

RESUMEN

(1) Background: When measuring anaerobic work threshold (AT), the conventional V-slope method includes the subjectivity of the examiner, which cannot be eliminated completely. Therefore, we implemented an engineering method using strucchange to objectively search for the inflection point of AT. (2) Methods: Seventeen subjects (15 men and 2 women) were included in the study. The subjects rode an ergometer and performed a ramp load test for 18 min and 30 s. (3) Results: In VE (Ventilation), 11 out of 12 subjects had the same results with 95% confidence intervals for the AT by the strucchange and respiratory metabolic apparatus. In VCO2 (Carbon dioxide emissions), 9 out of 12 subjects had the same results with 95% confidence intervals for the AT with the strucchange and respiratory metabolic apparatus. In VE, 3 out of 12 subjects showed the same results for respiratory metabolic analysis and the AT by the V-slope method. In VCO2, 3 out of 12 subjects showed the same results for the respiratory metabolic analysis and AT by the V-slope method in VCO2. (4) Conclusions: Strucchange was more objective and significant in identifying the AT than the V-slope method.


Asunto(s)
Umbral Anaerobio , Consumo de Oxígeno , Dióxido de Carbono/metabolismo , Prueba de Esfuerzo , Femenino , Humanos , Pulmón , Masculino , Ventilación Pulmonar , Respiración
16.
Eat Weight Disord ; 27(8): 3553-3560, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36271269

RESUMEN

PURPOSE: Patients with anorexia nervosa (AN) require appropriate nutrient therapy and physical activity management. Eating disorder treatment guidelines do not include safe, evidence-based intensity criteria for exercise. This study used cardiopulmonary exercise testing (CPX) to evaluate the exercise tolerance of patients with AN. METHODS: CPX was performed with 14 female patients with AN admitted to a specialized eating disorder unit between 2015 and 2019. Their anaerobic threshold (AT) was determined by assessing their exercise tolerance using CPX and compared with 14 healthy controls (HC). The metabolic equivalents (AT-METS) were compared when AT was reached. We examined factors related to AT (AN-AT) in the AN group, including age, body mass index (BMI), previous lowest weight, minimum BMI, past duration of BMI < 15, exercise history, and ΔHR (heart rate at the AT-resting heart rate). RESULTS: The AT of the AN group (BMI: 15.7 [Mean] ± 1.8 standard deviation [SD]) was significantly lower than that of the HC group (BMI: 19.7 ± 1.8) (AN: 10.0 ± 1.8 vs. HC: 15.2 ± 3.0 ml/kg/min, P < 0.001). AT-METS was also significantly lower in the AN group than in the HC group (AN: 2.9 ± 0.52 vs. HC: 4.4 ± 0.91, P < 0.001). AN-AT was highly influenced by ΔHR. CONCLUSIONS: This study showed that AT and AT-METS were lower in patients with AN than in HC. Patients with AN should be prescribed light-intensity aerobic exercise, and the current findings may help develop future physical management guidelines for patients with AN. LEVEL OF EVIDENCE: III: Evidence obtained from case-control analytic studies.


Asunto(s)
Anorexia Nerviosa , Trastornos de Alimentación y de la Ingestión de Alimentos , Humanos , Femenino , Prueba de Esfuerzo , Anorexia Nerviosa/terapia , Estudios de Casos y Controles , Índice de Masa Corporal
17.
Biol Sport ; 39(3): 599-606, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35959324

RESUMEN

The aim was to assess the relationship between aerobic fitness and metabolic power metrics in elite male soccer players, and the possible differences that playing positions might impose during match play over new metabolic power metrics. Sixty-two elite professional male soccer players (13 central backs, 13 side backs, 22 midfielders, and 14 forwards) took part in the study. Players were monitored during eleven months of full training (including pre-season and in-season) and over all official matches (Serie A matches, Italy Cup matches). Aerobic fitness tests were conducted one week after the start of the preseason, and 8, 24 and 36 weeks after the beginning of the Championship. Players' aerobic fitness and metabolic power metrics were considered as the mean of all seasonal testing and of pooling data of 38 championship matches and 3 or 6 Italy Cup matches for all the calculations respectively. The velocity at 4 mmol·L-1 (VL4) was significantly related to metabolic power metrics match variables with correlation ranging from trivial to very large (r = 0.32 to r = 0.89). Receiver-operating-characteristic (ROC) analysis showed that speed at VL4 was sensitive in detecting high metabolic power distance (HMPD) changes in all but central back players as revealed by area under the curve (central back .78, 95%CI .47 to .95; full back .93, 95%CI .64 to 0.99; midfielder .88, 95%CI .67 to 0.98; forward .90, 95%CI .62 to 0.99). This study's findings provide further evidence for the ecological validity of aerobic fitness in elite male soccer players. Players having a HMPD cut-off equal to or higher than > 1450 m for central backs, > 1990 m for full backs, > 2170 m for midfielders and > 1670 m for forwards may be considered as possessing superior aerobic fitness status. In light of this study's findings, the VL4 test may be considered a valid test to evaluate meaningful information for direct generic aerobic training in soccer players.

18.
Br J Anaesth ; 126(1): 181-190, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32690247

RESUMEN

BACKGROUND: Accurate assessment of functional capacity, a predictor of postoperative morbidity and mortality, is essential to improving surgical planning and outcomes. We assessed if all 12 items of the Duke Activity Status Index (DASI) were equally important in reflecting exercise capacity. METHODS: In this secondary cross-sectional analysis of the international, multicentre Measurement of Exercise Tolerance before Surgery (METS) study, we assessed cardiopulmonary exercise testing and DASI data from 1455 participants. Multivariable regression analyses were used to revise the DASI model in predicting an anaerobic threshold (AT) >11 ml kg-1 min-1 and peak oxygen consumption (VO2 peak) >16 ml kg-1 min-1, cut-points that represent a reduced risk of postoperative complications. RESULTS: Five questions were identified to have dominance in predicting AT>11 ml kg-1 min-1 and VO2 peak>16 ml.kg-1min-1. These items were included in the M-DASI-5Q and retained utility in predicting AT>11 ml.kg-1.min-1 (area under the receiver-operating-characteristic [AUROC]-AT: M-DASI-5Q=0.67 vs original 12-question DASI=0.66) and VO2 peak (AUROC-VO2 peak: M-DASI-5Q 0.73 vs original 12-question DASI 0.71). Conversely, in a sensitivity analysis we removed one potentially sensitive question related to the ability to have sexual relations, and the ability of the remaining four questions (M-DASI-4Q) to predict an adequate functional threshold remained no worse than the original 12-question DASI model. Adding a dynamic component to the M-DASI-4Q by assessing the chronotropic response to exercise improved its ability to discriminate between those with VO2 peak>16 ml.kg-1.min-1 and VO2 peak<16 ml.kg-1.min-1. CONCLUSIONS: The M-DASI provides a simple screening tool for further preoperative evaluation, including with cardiopulmonary exercise testing, to guide perioperative management.


Asunto(s)
Prueba de Esfuerzo/métodos , Prueba de Esfuerzo/estadística & datos numéricos , Tolerancia al Ejercicio , Estado de Salud , Complicaciones Posoperatorias/prevención & control , Cuidados Preoperatorios/métodos , Anciano , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Medición de Riesgo , Encuestas y Cuestionarios/estadística & datos numéricos
19.
Heart Vessels ; 36(12): 1811-1817, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33990894

RESUMEN

The anaerobic threshold (AT), obtained during cardiopulmonary exercise testing (CPET), is an important prognostic measure and can be used to develop an exercise prescription in patients after a myocardial infarction (post-MI). The purpose of this study was to examine the central and peripheral determinants of AT in post-MI patients end-tidal oxygen partial pressure (PETO2) measures. We performed cardiopulmonary exercise testing (CPET) on 148 consecutively enrolled post-MI patients to determine PETO2 measured at the AT (AT PETO2) and ΔPETO2 (difference between resting PETO2 and AT PETO2). We subsequently investigated the relationship between these measures of PETO2 and the individual AT for each patient. Multivariate linear regression analysis indicated that AT PETO2 and ΔPETO2 were independently and significantly associated with the AT (ß = -0.344, p < 0.001 and ß = 0.228, p < 0.001, respectively). Furthermore, the independent factors of AT PETO2 were left ventricular ejection fraction (p = 0.005), resting ventilatory equivalent for carbon dioxide (p = 0.002), and resting dead-space gas volume to tidal volume ratio (p < 0.001). However, the independent factors for ΔPETO2 were history of diabetes (p = 0.047), estimated glomerular filtration rate (p = 0.001), and resting systolic blood pressure (p = 0.017). These findings suggested that AT PETO2 was associated with central determinants; whereas, and ΔPETO2 was associated with peripheral determinants, The AT PETO2 and ΔPETO2 provide variable insight regarding the cause of exercise intolerance and can be used to determine appropriate therapies.


Asunto(s)
Umbral Anaerobio , Infarto del Miocardio , Prueba de Esfuerzo , Humanos , Infarto del Miocardio/diagnóstico , Oxígeno , Consumo de Oxígeno , Presión Parcial , Volumen Sistólico , Función Ventricular Izquierda
20.
Heart Vessels ; 36(6): 766-774, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33484291

RESUMEN

Anaerobic threshold (AT) from cardiopulmonary exercise tests (CPX) is the standard for measuring exercise intensity among patients with cardiovascular disease in Japan. However, it remains controversial whether AT represents the safety limit for exercise intensity in patients with cardiovascular disease. The purpose of this study was to investigate cardiac rehabilitation (CR) efficacy and safety with exercise intensities above the AT and at a traditional AT in a randomized trial. The participants included 57 patients who were admitted to the outpatient CR unit with a diagnosis of acute myocardial infarction. The participants were randomly divided as follows: 25 patients in the AT group, who performed aerobic exercises with an intensity at the AT; and 32 patients in the "Over AT" group, who performed exercises at an intensity higher than the AT. The following components were measured: maximum oxygen uptake (peak VO2), oxygen uptake at the AT (AT VO2), increase in oxygen uptake during exercise (ΔVO2/ΔWR) during the CPX, vascular endothelial function test (%FMD: the percentage of flow-mediated dilation), and isometric knee extension strength. The measurements were obtained at the start of the exercise therapy and after 2, 3, and 4 months. They were compared within and between groups, and the correlation between the rates of improvement was investigated. Peak VO2, AT VO2, ΔVO2/ΔWR, and %FMD had significantly improved after 3 months in both groups. The isometric knee extension strength had improved in the "Over AT" group after 2 months. Interactions were observed with peak VO2, ΔVO2/ΔWR, and isometric knee extension strength. However, %FMD was not significantly different between the groups. In the "Over AT" group, the rate of improvement in peak VO2 was positively correlated with the improvement in the isometric knee extension strength (r = 0.61, p < 0.001), but not with %FMD. These data suggest that exercise at an intensity above the AT improved exercise tolerance faster than that at the AT, and this improvement rate was associated with changes in isometric knee extension strength.


Asunto(s)
Umbral Anaerobio/fisiología , Rehabilitación Cardiaca/métodos , Terapia por Ejercicio/métodos , Tolerancia al Ejercicio/fisiología , Infarto del Miocardio/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/rehabilitación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA