Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(5): 984-993, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38486082

RESUMEN

INTRODUCTION: Little is known about very early atrial fibrillation (AF) ablation after first AF detection. METHODS: We evaluated patients with AF ablation <4 months from newly diagnosed paroxysmal AF (NEWPaAF) and newly diagnosed persistent AF (NEWPeAF). We compared the two patient populations and compared ablation outcomes to those undergoing later ablation. RESULTS: Ablation was done <4 months from AF diagnosis in 353 patients (135 = paroxysmal, 218 = persistent). Early ablation outcome was best for NEWPaAF versus NEWPeAF for initial (p = 0.030) but not final (p = 0.102) ablation. Despite recent AF diagnosis in both groups, they were clinically quite different. NEWPaAF patients were younger (64.3 ± 13.0 vs. 67.3 ± 10.9, p = 0.0020), failed fewer drugs (0.39 vs. 0.60, p = 0.007), had smaller LA size (4.12 ± 0.58 vs. 4.48 ± 0.59 cm, p < 0.0001), lower BMI (28.8 ± 5.0 vs. 30.3 ± 6.0, p = 0.016), and less CAD (3.7% vs. 11.5%, p = 0.007), cardiomyopathies (2.2% vs. 22.9%, p = 0.0001), hypertension (46.7% vs. 67.4%, p < 0.0001), diabetes (8.1% vs. 17.4%, p = 0.011) and sleep apnea (20.0% vs. 30.3%, p = 0.031). For NEWPaAF, early ablation AF-free outcome was no better than later ablation (p = 0.314). For NEWPeAF, AF-free outcomes were better for early ablation than later ablation (p < 0.0001). Delaying ablation allowed more strokes/TIAs in both AF types (paroxysmal p = 0.014, persistent p < 0.0001). CONCLUSIONS: Patients presenting for early ablation after newly diagnosed persistent AF have more pre-existing comorbidities and worse initial ablation outcomes than patients with NEWPaAF. For NEWPaAF, there was no advantage to early ablation, as long as the AF remained paroxysmal. For NEWPeAF, early ablation gave better outcomes than later ablation and they should undergo early ablation. For both AF types, waiting was associated with more neurologic events, suggesting all patients should consider earlier ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Masculino , Ablación por Catéter/efectos adversos , Femenino , Persona de Mediana Edad , Factores de Tiempo , Anciano , Factores de Riesgo , Resultado del Tratamiento , Frecuencia Cardíaca , Tiempo de Tratamiento , Potenciales de Acción , Estudios Retrospectivos
2.
J Cardiovasc Electrophysiol ; 35(8): 1570-1578, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38837730

RESUMEN

BACKGROUND: Same day discharge (SDD) following atrial fibrillation (AF) ablation procedure has emerged as routine practice, and primarily driven by operator discretion. However, the impacts of SDD on clinical outcomes, healthcare system costs, and patient reported outcomes (PROs) have not been systematically studied. METHODS: We retrospectively analyzed patients undergoing routine AF ablation procedures with SDD versus overnight observation (NSDD). After propensity adjustment we compared postprocedure adverse events (AEs), healthcare system costs, and changes in PROs. RESULTS: We identified 310 cases, with 159 undergoing SDD and 151 staying at least one midnight in the hospital (NSDD). Compared with NSDD, SDD patients were similar age (mean 64 vs. 66, p = 0.3), sex (26% female vs. 27%, p = 0.8), and with lower mean CHADS2-VA2Sc scores (2.0 vs. 2.7; p < 0.011). The primary outcome of AEs was noninferior in SDD versus NSDD patients (odds ratio 0.45, 95% confidence interval 0.21-0.99; noninferiority margin of 10%). There were also no differences in overall cost to the healthcare system between SDD and NSDD (p = 0.11). PROs numerically favored SDD (p = NS for all scores). CONCLUSIONS: Physician selection for SDD appears at least as safe as NSDD with respect to clinical outcomes and SDD is not significantly less costly to the health system. There is a trend towards more favorable, general PROs among SDD patients. Routine SDD should be strongly considered for patients undergoing routine AF ablation procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Alta del Paciente , Medición de Resultados Informados por el Paciente , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/economía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Estudios Retrospectivos , Ablación por Catéter/economía , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Factores de Tiempo , Alta del Paciente/economía , Costos de Hospital , Factores de Riesgo , Análisis Costo-Beneficio , Tiempo de Internación/economía , Procedimientos Quirúrgicos Ambulatorios/economía , Procedimientos Quirúrgicos Ambulatorios/efectos adversos
3.
J Cardiovasc Electrophysiol ; 35(3): 440-450, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38282445

RESUMEN

INTRODUCTION: During atrial fibrillation ablation (AFA), achievement of first pass isolation (FPI) reflects effective lesion formation and predicts long-term freedom from arrhythmia recurrence. We aim to determine the clinical and procedural predictors of pulmonary vein FPI. METHODS: We reviewed AFA procedures in a multicenter prospective registry of AFA (REAL-AF). A multivariate ordinal logistic regression, weighted by inverse proceduralist volume, was used to determine predictors of FPI. RESULTS: A total of 2671 patients were included with 1806 achieving FPI in both vein sides, 702 achieving FPI in one, and 163 having no FPI. Individually, age, left atrial (LA) scar, higher power usage (50 W), greater posterior contact force, ablation index >350 posteriorly, Vizigo™ sheath utilization, nonstandard ventilation, and high operator volume (>6 monthly cases) were all related to improved odds of FPI. Conversely sleep apnea, elevated body mass index (BMI), diabetes mellitus, LA enlargement, antiarrhythmic drug use, and center's higher fluoroscopy use were related to reduced odds of FPI. Multivariate analysis showed that BMI > 30 (OR 0.78 [0.64-0.96]) and LA volume (OR per mL increase = 1.00 [0.99-1.00]) predicted lower odds of achieving FPI, whereas significant left atrial scarring (>20%) was related to higher rates of FPI. Procedurally, the use of high power (50 W) (OR 1.32 [1.05-1.65]), increasing force posteriorly (OR 2.03 [1.19-3.46]), and nonstandard ventilation (OR 1.26 [1.00-1.59]) predicted higher FPI rates. At a site level, high procedural volume (OR 1.89 [1.48-2.41]) and low fluoroscopy centers (OR 0.72 [0.61-0.84]) had higher rates of FPI. CONCLUSION: FPI rates are affected by operator experience, patient comorbidities, and procedural strategies. These factors may be postulated to impact acute lesion formation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Estudios Prospectivos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Cicatriz , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Estudios Multicéntricos como Asunto
4.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38306687

RESUMEN

AIMS: Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether the timely pre-emptive catheter ablation would achieve higher freedom from AF or atrial tachycardia (AT) and be associated with better clinical outcomes than surgical ablation alone. METHODS AND RESULTS: The trial investigated patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement with mandatory concomitant CryoMaze procedure who were randomly assigned to undergo either radiofrequency catheter ablation [Hybrid Group (HG)] or no further treatment (Surgery Group). The primary efficacy endpoint was the first recurrence of AF/AT without class I or III antiarrhythmic drugs as assessed by implantable cardiac monitors. The primary clinical endpoint was a composite of hospitalization for arrhythmia recurrence, worsening of heart failure, cardioembolic event, or major bleeding. We analysed 113 and 116 patients in the Hybrid and Surgery Groups, respectively, with a median follow-up of 715 (IQR: 528-1072) days. The primary efficacy endpoint was significantly reduced in the HG [41.1% vs. 67.4%, hazard ratio (HR) = 0.38, 95% confidence interval (CI): 0.26-0.57, P < 0.001] as well as the primary clinical endpoint (19.9% vs. 40.1%, HR = 0.51, 95% CI: 0.29-0.86, P = 0.012). The trial groups did not differ in all-cause mortality (10.6% vs. 8.6%, HR = 1.17, 95%CI: 0.51-2.71, P = 0.71). The major complications of catheter ablation were infrequent (1.9%). CONCLUSION: Pre-emptively performed catheter ablation after the CryoMaze procedure was safe and associated with higher freedom from AF/AT and improved clinical outcomes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Resultado del Tratamiento , Taquicardia Supraventricular/cirugía , Antiarrítmicos/uso terapéutico , Hemorragia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
5.
Curr Probl Cardiol ; 49(1 Pt C): 102183, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37913928

RESUMEN

BACKGROUND: A growing body of evidence is supportive of early atrial fibrillation (AF) ablation to maintain sinus rhythm. Disparities in health care between rural and urban areas in the United States are well known. Catheter ablation (CA) of AF is a complex procedure and its outcomes among rural versus urban areas has not been studied in the past. METHODS: The national inpatient sample database 2016-2020 was queried for all hospitalization with the primary diagnosis of AF who underwent AF catheter ablation at the index hospitalization. Then, hospitalizations were stratified into rural versus urban. The primary outcome was in-hospital mortality. Secondary outcomes were total hospitalization costs and likelihood for longer length of stay. RESULTS: A total of 78,735 patients underwent inpatient CA of AF between January 2016 and December 2020, mean age was 68.5 ± 11 with 44 % being females. 27,180 (35 %) CA were performed in rural areas, while the remaining CA  51,555 (65 %) were done in urban areas. While, there was very low risk of mortality, patients who underwent CA in rural areas had more comorbidities and also was associated with a 79 % increase in post-procedural in-hospital mortality compared with urban areas (aOR 1.79, 0.8 % vs 0.4 %, CI: 1.15-2.78, P < 0.01). CA of AF in rural areas had a longer length of hospital stay (aOR 1.11, 4.21 vs 3.79 days, 95 % CI: 1.02-1.2, P = 0.02), lower overall cost compared with urban areas (49,698 ± 1251 vs. $53,252 ± 1339, P = 0.03). Multivariate regression analysis showed end stage renal disease and congestive heart failure were independent risk factors associated with increase in post CA in-hospital mortality exceeding two-fold. CONCLUSION: Inpatient CA of AF in rural areas was associated with higher in-hospital mortality, longer length of stay and a lower overall cost when compared with urban areas.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Estados Unidos/epidemiología , Persona de Mediana Edad , Anciano , Masculino , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Pacientes Internos , Hospitalización , Tiempo de Internación , Ablación por Catéter/métodos , Resultado del Tratamiento
6.
Artículo en Inglés | MEDLINE | ID: mdl-39141267

RESUMEN

BACKGROUND AND AIMS: Catheter ablation is superior to pharmacological therapy in controlling atrial fibrillation (AF). There are few data on the long-term outcome of AF ablation in octogenarian patients. This analysis aims to evaluate the outcome of AF ablation in octogenarians vs. younger patients. METHODS: In this retrospective study in 13 centres in the UK, France, and Switzerland, the long-term outcomes of 473 consecutive octogenarian patients undergoing ablation for AF were compared to 473 matched younger controls (median age 81.3 [80.0, 83.0] vs. 64.4 [56.5, 70.7] years, 54.3% vs. 35.1% females; p-value for both < 0.001). The primary endpoint was the recurrence of atrial arrhythmia after a blanking period of 90 days within 365 days of follow-up. RESULTS: Acute ablation success as defined as isolation of all pulmonary veins was achieved in 97% of octogenarians. Octogenarians experienced more procedural complications (11.4% vs 7.0%, p = 0.018). The median follow-up time was 281 [106, 365] days vs. 354 [220, 365] days for octogenarians vs. non-octogenarians (p < 0.001). Among octogenarians, 27.7% (131 patients) experienced a recurrence of atrial arrhythmia, in contrast to 23.5% (111 patients) in the younger group (odds ratio 1.49; 95% confidence interval 1.16-1.92; p = 0.002). In a multivariable regression model including gender, previous AF ablation, vascular disease, chronic kidney disease, CHA2DS2-VASc score, left atrial dilatation, and indwelling cardiac implantable electronic device, age above 80 remained an independent predictor of recurrence of arrhythmia. CONCLUSION: Ablation for AF is effective in octogenarians, but is associated with slightly higher procedural complication rate and recurrence of atrial arrhythmia than in younger patients.

7.
Acta Cardiol ; : 1-8, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38334112

RESUMEN

BACKGROUND: We aimed to share our methods and experience of persistent AF ablation without a circular mapping catheter (CMC), thereby avoiding femoral venous and transseptal punctures, decreasing the cost of the procedure, and possibly reducing the duration of the procedure and fluoroscopy time. METHODS: We report our experience with 261 persistent AF ablations performed without a CMC over the past 3 years. RESULTS: The procedures were performed with no apparent loss of efficacy or safety. Freedom from recurrence was defined as a 1-year absence of AF/atrial flutter (AFL) episodes >30 s, beyond the 3-month blanking period. At 1 year, 72% of the patients were free from arrythmias. CONCLUSIONS: Persistent AF ablation is feasible without a CMC, reducing the need for venous and transseptal punctures and the cost of the procedure. We suggest that prospective studies should aim to characterise the reduction in procedure and fluoroscopy times as a result of this technique.

8.
Artículo en Alemán | MEDLINE | ID: mdl-39023744

RESUMEN

Thyroid dysfunction is associated with characteristic changes in heart rate and arrhythmias. Thyroid hormones act through genomic and non-genomic effects on myocytes and influence contractility, relaxation and action potential duration through a variety of mechanisms. Atrial fibrillation is the most common arrhythmia associated with thyroid dysfunction, it occurs in both euthyroidism and hyperthyroidism in clear association with T4 levels. Mechanistically, in the hyperthyroid state, increased automaticity and triggered activity, together with a shortened refractory period and slowing of the conduction speed, lead to the initiation and maintenance of multiple intraatrial reentry circuits. Influences from the autonomic nervous system and hemodynamics controlled by thyroid hormones act as modulators for arrhythmias, which are promoted by a corresponding substrate (significant impact of comorbidities). Concerning therapy, in addition to treating hyperthyroidism, the initial therapeutic focus is on adequate rate control and anticoagulation in patients with a high risk of thromboembolism. Ablation of atrial fibrillation can be considered later on, although there is an increased likelihood of recurrence compared to patients without hyperthyroidism.Prolongation of the QT interval and increase in QT dispersion are involved in the formation of ventricular arrhythmias. Epidemiological data suggest an association of elevated T4 levels with ventricular arrhythmias and sudden cardiac death. However, this seems to be mainly relevant for patients with underlying cardiac disease (e.g. ICD users).

9.
Artículo en Inglés | MEDLINE | ID: mdl-39024017

RESUMEN

OBJECTIVES: Our goal was to investigate sinus node dysfunction (SND) as a rare complication following surgical and catheter atrial fibrillation (AF) ablation in patients with an aberrant sinus node artery (SNA). METHODS: We used a retrospective analysis of 3 patients with an aberrant SNA who underwent different AF ablation procedures: 1 concomitant to aortic valve replacement, 1 thoracoscopic hybrid AF ablation and 1 catheter AF ablation. RESULTS: All patients experienced temporary SND perioperatively. In the first patient, sinus rhythm (SR) recovered by postoperative day 6. In the second patient, SR returned by postoperative day 14. The third patient had a sinus arrest during ablation that restored to SR immediately post-procedure. All patients had normal SR at the 3-month follow-up. CONCLUSIONS: Awareness of SNA anatomy can help to prevent iatrogenic SND during AF ablation. If SND occurs, a wait-and-see approach is recommended, given that sinus node function seems to recover. Because SND recovers, the benefits of posterior wall isolation could outweigh the disadvantages of temporary SND.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38632136

RESUMEN

BACKGROUND: Sinus node dysfunction (SND) is commonly seen in patients with atrial fibrillation (AF). The purpose of this study was to compare the incidence of pacemaker implantation among patients with SND and AF treated with catheter ablation (CA) versus anti-arrhythmic drugs (AADs). METHODS: The 2013-2022 Optum Clinformatics database, an administrative claims database for commercially insured individuals in the United States (US), was used for this study. Patients with AF and SND and a history of at least one AAD prescription were identified and classified into CA or AAD cohorts based on subsequent treatment received. Inverse probability treatment weighting was applied to balance socio-demographic and clinical characteristics between the cohorts. Weighted Cox regression modeling was used to evaluate the differential risk of incident permanent pacemaker (PPM) implantation. Sub-analyses were performed by AF type (paroxysmal versus persistent). RESULTS: A total of 1206 patients in the AAD cohort and 1624 patients in the CA cohort were included. Study cohorts were well-balanced post-weighting. The incidence rate of PPM implantation (per 1000 person-year) was 55.8 for the CA cohort and 117.8 for the AAD cohort. Regression analysis demonstrated that the CA cohort had 42% lower risk of incident PPM implantation than those treated with AADs (hazard ratio [HR], 0.58; 95% CI, 0.46-0.72, p < 0.001). CA-treated patients had lower risks of PPM implantation versus AAD-treated patients among those with paroxysmal AF (HR, 0.48; 95% CI, 0.34-0.69, p < 0.001) and persistent AF (HR, 0.57; 95% CI, 0.40-0.81, p = 0.002). CONCLUSIONS: Patients with AF and SND treated with CA have significantly lower risks of incident PPM implantation compared with those treated with an AAD.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38775921

RESUMEN

BACKGROUND: Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of cardiac implantable electronic devices (CIEDs) in the form of electromagnetic interference (EMI). The aim of our study was to assess the impact of PFA on CIEDs. METHODS: PFA lesions (45 per CIED) were applied from the Farapulse system to CIEDs (< 5 cm from the lead tip and < 15 cm from the generator). All devices were checked before and after PFA application for proper sensing and pacing functionality as well as for integrity of shock circuits in ICDs using a heart simulator. Moreover, devices were then interrogated for any spontaneous reprogramming, mode switching or other EMI effects. RESULTS: In total, 44 CIEDs were tested (16 pacemaker, 21 ICDs, 7 CRT-P/D) with 1980 PFA applications. There was no change in device settings, functionality and electrical parameters, and there was no macroscopic damage to the devices. The risk of damage to the electric components or leads on a patient-based analysis is 0/44 (95% CI 0-8%) and on a PFA pulse-based analysis is 0/1980 (95% CI 0-0.2%). Clinically relevant EMI appeared with oversensing and pacing inhibition but not tachycardia detection. CONCLUSIONS: Bipolar PFA appears safe and does not result in damage to CIEDs or leads. Clinically relevant EMI does occur, but appropriate peri-procedural programming may mitigate this. In vivo studies are needed to confirm our findings.

12.
Artículo en Inglés | MEDLINE | ID: mdl-39078545

RESUMEN

BACKGROUND: Vein of Marshall (VoM) ethanol ablation has a proven benefit in patients with persistent atrial fibrillation (AF) undergoing index procedure; however, its role in repeat ablation is unknown. We sought to evaluate the benefit of empiric VoM ethanol ablation in addition to posterior wall isolation (PWI) during the repeat procedure in patients with durable pulmonary vein (PV) isolation from prior ablation. METHODS: Twenty-three patients (age 67.1 + / - 7.4, 74% males) who received empiric VoM ethanol infusion in addition to PWI were matched for age, gender, ejection fraction, and left atrial size with forty-six patients receiving empiric PWI alone. All patients in the study group underwent additional ablation on mitral isthmus to complete the lateral mitral isthmus line. Additional ablation was based on program and trigger stimulation. Primary outcome was freedom from AF after a blanking period of 3 months by qualification of symptoms, EKG, wearable, or implantable monitor or device. RESULTS: The study group had a higher average BMI (35.07 + / - 8.98 vs. 30.85 + / - 5.65, p = 0.033) and rate of persistent AF (83.0% vs. 54.3%, p = 0.029) versus the control. The 1-year AF-free survival for the study and control groups was 20 (86.96%) and 28 (60.1%) patients (p = 0.027). Cox proportional hazard regression analysis showed a significant reduction in AF recurrence in the study group (HR 0.25, 95% CI 0.073-0.843, p = 0.026). CONCLUSION: Among patients undergoing repeat catheter ablation for recurrent AF with durably isolated PVs, the addition of VoM ethanol infusion increased the likelihood of remaining free from AF at 12 months.

13.
Ann Cardiothorac Surg ; 13(2): 135-145, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38590994

RESUMEN

Current guidelines recommend concomitant surgical ablation (SA) of atrial fibrillation (AF) in the context of mitral valve disease. A variety of energy sources have been tested for SA to perform effective transmural lesions reliably. To date, only radiofrequency and cryothermy energies are considered viable options. The gold standard for SA is the Cox-Maze ablation set, especially for non-paroxysmal AF (nPAF), with the aim of interrupting macro-reentrant drivers perpetuating AF, without hampering the sinus node activation of both atria, and to maintain the atrioventricular synchrony. Although the efficacy of SA in terms of early and late sinus rhythm restoration has been clearly demonstrated over the years, concomitant AF ablation is still underperformed in patients with AF undergoing cardiac surgery. From a surgical standpoint, concerns have been raised about whether a single (left) or double atriotomy would be justified in AF patients undergoing a "non-atriotomy" surgical procedure, such as aortic valve or revascularization surgery. Thus, an array of simplified lesion sets have been described in the last decade, which have unavoidably hampered procedural efficacy, somewhat jeopardizing the standardization process of ablation surgery. As a matter of fact, the term "Maze" has improperly become a generic term for SA. Surgical interventions that do not align with the principles of forming conduction-blocking lesions according to the Maze pattern, cannot be classified as Maze procedures. In this complex scenario, a tailored approach according to the different AF patterns has been proposed: for patients with concomitant nPAF, a biatrial Cox-Maze ablation is recommended. Conversely, it might be reasonable to limit lesions to the left atrium or the pulmonary veins in patients with paroxysmal AF (PAF) in some clinical scenarios. The aim of this review is to provide an overview of the current ablation strategies for patients with AF undergoing concomitant cardiac surgery.

14.
Clin Case Rep ; 12(5): e8856, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38725927

RESUMEN

Radiofrequency ablation for atrial fibrillation or atrial flutter is feasible in patients with deep brain stimulation but with extreme caution given the possibility of life-threatening complications.

15.
Card Electrophysiol Clin ; 16(2): 181-186, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38749639

RESUMEN

A 70-year-old man with recurrent atrial fibrillation (AF) underwent transcatheter radiofrequency ablation after an earlier unsuccessful attempt. Although typical AF triggers were ablated, the patient's condition persisted, leading to the identification of the interatrial septum (IAS) as the probable source of the tachycardia trigger. Given the depth and thickness of the IAS, traditional radiofrequency ablation proved ineffective. However, using the alternative method of bipolar radiofrequency catheter ablation (B-RFCA), the atrial tachycardia was successfully terminated. B-RFCA demonstrates potential for effectively terminating tachycardias originating from deep intramural locations, suggesting its potential as a pivotal technique for complex cases with septal atrial tachycardia.


Asunto(s)
Ablación por Catéter , Humanos , Masculino , Anciano , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Tabique Interatrial/cirugía , Tabique Interatrial/diagnóstico por imagen
16.
Heart Rhythm ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38960302

RESUMEN

BACKGROUND: The association of hospital and physician procedure volume with outcome has not been well evaluated for atrial fibrillation (AF) ablation in contemporary practice. OBJECTIVE: This study aimed to determine the association between hospital and physician AF ablation volume and procedural success (isolation of all pulmonary veins) and major adverse events (MAEs). METHODS: Procedures reported to the National Cardiovascular Data Registry AFib Ablation Registry between July 2019 and June 2022 were included. Hospital and physician procedural volumes were annualized and stratified into quartiles to compare outcomes. Three-level hierarchical (patient, hospital, and physician) models were used to assess the procedural volume-outcome relationship. RESULTS: A total of 70,296 first-time AF ablations at 186 US hospitals were included. Overall, procedural success and MAE rates were 98.5% and 1.0%, respectively. With hospital volume (Q4) as a reference, the likelihood of procedural success was lower for Q1 (odds ratio [OR], 0.44; 95% CI, 0.29-0.68), Q2 (OR, 0.50; 95% CI, 0.33-0.75), and Q3 (OR, 0.60; 95% CI, 0.40-0.89); the results were similarly significant for physician volume. With MAE for hospitals, there was an inverse procedural volume relationship for Q1 (OR, 1.78; 95% CI, 1.26-2.52) but not for Q2 (OR, 1.06; 95% CI, 0.77-1.46) or Q3 (OR, 1.19; 95% CI, 0.89-1.58) and similarly for physicians in Q1 and Q2 but not in Q3. An adjusted MAE ≤1% was predicted by an annual volume of approximately 190 for hospitals and 60 for physicians. CONCLUSION: In this national cohort, hospital and physician AF ablation procedural volumes were directly related to acute procedural success and inversely related to rates of MAE.

17.
J Cardiothorac Surg ; 19(1): 397, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937763

RESUMEN

OBJECTIVES: Current recommendations support surgical treatment of atrial fibrillation (AF) in patients indicated for cardiac surgery. These procedures are referred to as concomitant and may be carried out using radiofrequency energy or cryo-ablation. This study aimed to assess the electrophysiological findings in patients undergoing concomitant cryo-ablation. METHODS: Patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement were included in the trial if concomitant cryo-ablation was part of the treatment plan according to current guidelines. The patients reported in this study were assigned to undergo staged percutaneous radiofrequency catheter ablation (PRFCA), i.e., hybrid treatment, as a part of the SURHYB trial protocol. RESULTS: We analyzed 103 patients who underwent PRFCA 105 ± 35 days after surgery. Left and right pulmonary veins (PVs) were found isolated in 65 (63.1%) and 63 (61.2%) patients, respectively. The LA posterior wall isolation and mitral isthmus conduction block were found in 38 (36.9%) and 18 (20.0%) patients, respectively. Electrical reconnections (gaps) in the left PVs were more often localized superiorly than inferiorly (57.9% vs. 26.3%, P = 0.005) and anteriorly than posteriorly (65.8% vs. 31.6%, P = 0.003). Gaps in the right PVs were more equally distributed anteroposteriorly but dominated in superior segments (72.5% vs. 40.0%, P = 0.003). There was a higher number of gaps on the roof line compared to the inferior line (131 (67.2%) vs. 67 (42.2%), P < 0.001). Compared to epicardial cryo-ablation, endocardial was more effective in creating PVs and LA posterior wall isolation (P < 0.05). Cryo-ablation using nitrous oxide (N20) or argon (Ar) gas as cooling agents was similarly effective (P = NS). CONCLUSIONS: The effectiveness of surgical cryo-ablation in achieving transmural and durable lesions in the left atrium is surprisingly low. Gaps are located predominantly in the superior and anterior portions of the PVs and on the roof line. Endocardial cryo-ablation is more effective than epicardial ablation, irrespective of the cooling agent used.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Criocirugía/métodos , Masculino , Femenino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Venas Pulmonares/cirugía , Resultado del Tratamiento , Puente de Arteria Coronaria/métodos
18.
J Interv Card Electrophysiol ; 67(5): 1199-1210, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38321306

RESUMEN

BACKGROUND: The relationship between induction and recurrence due to atrial tachycardia (AT) and left atrial (LA) matrix progression after atrial fibrillation (AF) ablation remains unclear. METHODS: One hundred fifty-two consecutive patients with paroxysmal and persistent AF who underwent pulmonary vein isolation (PVI) and cavo-tricuspid isthmus (CTI) ablation and achieved sinus rhythm before the procedure were classified into three groups according to the AT pattern induced after the procedure: group N (non-induced), F (focal pattern), and M (macroreentrant pattern) in 3D mapping. RESULTS: The total rate of AT induction was 19.7% (30/152) in groups F (n = 13) and M (n = 17). Patients in group M were older than those in groups N and F, with higher CHADS2/CHA2DS2-VASc values, left atrial enlargement, and low-voltage area (LVA) size of LA. The receiver operating characteristic curve determined that the cut-off LVA for macroreentrant AT induction was 8.8 cm2 (area under the curve [AUC]: 0.86, 95% confidence interval [CI]: 0.75-0.97). The recurrence of AT at 36 months in group N was 4.1% (5/122), and at the second ablation, all patients had macroreentrant AT. Patients with AT recurrence in group N had a wide LVA at the first ablation, and the cut-off LVA for AT recurrence was 6.5 cm2 (AUC 0.94, 95%CI 0.88-0.99). Adjusted multivariate analysis showed that only LVA size was associated with the recurrence of macroreentrant AT (odds ratio 1.21, 95%CI 1.04-1.51). CONCLUSIONS: It is important to develop a therapeutic strategy based on the LVA size to suppress the recurrence of AT in these patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Masculino , Femenino , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Taquicardia Supraventricular/cirugía , Atrios Cardíacos/cirugía , Atrios Cardíacos/fisiopatología , Estudios Retrospectivos
19.
J Clin Med ; 13(1)2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38202216

RESUMEN

Pulmonary vein isolation (PVI), as the cornerstone of atrial fibrillation (AF) ablation, has emerged a widely used therapy for patients suffering from AF. To improve PVI efficiency, single-shot catheters (SSCs) have been developed. Regrettably, SSCs are not integrated into 3D-mapping technology. In that regard, a novel radiofrequency balloon catheter (RFBC, Heliostar, Biosense Webster) with full integration into 3D-mapping technology has been developed. The aim of this study was to assess operative and follow-up outcomes of the RFBC in AF patients. In this monocentric prospective registry, patients with a first-time PVI using the RFBC were included. Follow-up visits were scheduled 3, 6, 12 and 24 months after ablation and in case of symptoms. A total of 171 patients (36.8% female) were included, with a mean age of 68.5 ± 10.2 years. Among them, 63 patients (36.8%) presented with persistent AF. Notably, no major periprocedural complications were observed. The mean follow-up period was 287 ± 157 days. In the Kaplan-Meier analysis, the estimated recurrence-free survival after 12 months was 81.8%. Based on our data, PVI with the fully 3D-mapping-integrated RFBC seems to be safe and effective and to have a favorable 12-month outcome in patients with paroxysmal and persistent AF.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA