Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Am J Physiol Heart Circ Physiol ; 326(3): H812-H820, 2024 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-38276950

RESUMEN

Our study aimed to elucidate the role of different shunts and provide novel insights into optimal treatment approaches for complete transposition of the great arteries (TGA), which is characterized by unique and complicated circulatory dynamics. We constructed a computational cardiovascular TGA model and manipulated cardiovascular parameters, such as atrial septal defect (ASD) and patent ductus arteriosus (PDA) sizes, to quantify their effects on oxygenation and hemodynamics. In addition, ASD flow patterns were investigated as innovative indications for balloon atrial septostomy (BAS). Our model of TGA with an intact ventricular septum (TGA-IVS) showed that a large ASD can achieve sufficient mixing for survival without PDA, and the presence of PDA is detrimental to oxygen delivery. A treatment strategy for TGA-IVS that enlarges the ASD as much as possible by BAS and PDA closure would be desirable. In TGA with a ventricular septal defect (TGA-VSD), the VSD allows for higher oxygenation and reduces the detrimental effects of PDA on systemic circulation. In TGA-VSD, both strategies of enlarging the ASD by BAS with a closed PDA and adjusting the PDA in response to pulmonary vascular resistance (PVR) reduction without BAS may be effective. The simulated ASD flow patterns showed that the sharp peak left-to-right flow pattern in systole (σ-wave) reflected the hemodynamically significant ASD size, independent of PDA, VSD, and PVR. The ASD flow pattern visualized by Doppler echocardiography provides clinical insights into the significance of an ASD and indications for BAS, which are not readily apparent through morphological assessment.NEW & NOTEWORTHY Complete transposition of the great arteries (TGA) represents complex and unique circulation that is dependent on blood mixing through multiple interacting shunts. Consequently, the role of each shunt and the treatment strategy remain unclear. We developed a mathematical model of TGA circulation, revealing the significant influence of atrial septal defect (ASD) on oxygenation and hemodynamics. The blood flow pattern through the ASD reflects its hemodynamic impact and helps determine treatment strategies.


Asunto(s)
Defectos del Tabique Interatrial , Defectos del Tabique Interventricular , Transposición de los Grandes Vasos , Humanos , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Hemodinámica , Arterias
2.
Catheter Cardiovasc Interv ; 103(2): 308-316, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38091308

RESUMEN

BACKGROUND: Balloon atrial septostomy (BAS) is an emergent and essential cardiac intervention to enhance intercirculatory mixing at atrial level in deoxygenated patients diagnosed with transposition of the great arteries (TGA) and restrictive foramen ovale. The recent recall of several BAS catheters and the changes in the European legal framework for medical devices (MDR 2017/745), has led to an overall scarcity of BAS catheters and raised questions about the use, safety, and experience of the remaining NuMED Z-5 BAS catheter. AIMS: To evaluate and describe the practice and safety of the Z-5 BAS catheter, and to compare it to the performance of other BAS catheters. METHODS: A retrospective single-center cohort encompassing all BAS procedures performed with the Z-5 BAS catheter in TGA patients between 1999 and 2022. RESULTS: A total of 182 BAS procedures were performed in 179 TGA-newborns at Day 1 (IQR 0-5) days after birth, with median weight of 3.4 (IQR 1.2-5.7) kg. The need for BAS was urgent in 90% of patients. The percentage of BAS procedures performed at bedside increased over time from 9.8% (before 2010) to 67% (2017-2022). Major complication rate was 2.2%, consisting of cerebral infarction (1.6%) and hypovolemic shock (0.5%). The rate of minor complications was 9.3%, including temporary periprocedural AV-block (3.8%), femoral vein thrombosis (2.7%), transient intracardiac thrombus (0.5%), and atrial flutter (2.2%). BAS procedures performed at bedside and in the cardiac catheterization laboratory had similar complication rates. CONCLUSIONS: BAS using the Z-5 BAS catheter is both feasible and safe at bedside and at the cardiac catheterization laboratory with minimal major complications.


Asunto(s)
Transposición de los Grandes Vasos , Humanos , Recién Nacido , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Transposición de los Grandes Vasos/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Catéteres , Arterias
3.
Pediatr Cardiol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39123074

RESUMEN

Balloon atrial septostomy (BAS) reduces left ventricular (LV) hypertension during extracorporeal membrane oxygenation (ECMO). However, the acute effect of BAS on LV function as measured by echocardiography is unknown. This was a Retrospective analysis of clinical outcome, LV dimensions, and LV function in dilated cardiomyopathy patients 0-18 years old who underwent BAS on ECMO. In 13 patients with median (IQR) age of 2.3 (0.6-10.9) years, there were no differences in clinical markers of cardiac output at intervals between 12 h before and 6 days after BAS. In addition, BAS was associated with a low rate of periprocedural complications (0.0%), acute kidney injury (7.7%), and worsening radiographic pulmonary vascular congestion (30.7%). There was a significant worsening in LV end systolic diameter (LVIDs; 3.6 [2.9-4.8] cm vs 4.2 [3.2-5.6] cm vs 3.3 [2.6-4.6] cm, p = 0.025), LV end systolic posterior wall thickness (LVPWs; 0.7 [0.5-0.9] cm vs 0.6 [0.5-0.9] cm vs 0.8 [0.6-1.2] cm, p = 0.038), fractional shortening (FS; 17.6% [8.4-20.4%] vs 6.3% [2.0-9.9%] vs 13.2% [3.6-23.4%], p = 0.013), and ejection fraction (EF; 13.1% [8.7-18.9%] vs 5.3% [2.5-11.1%] vs 9.2% [6.0-16.3%], p = 0.039) following BAS that improved in approximately 1 week. There were no differences in LV global longitudinal strain following BAS. We conclude that BAS was associated with low procedural and clinical adverse event rates in our cohort. The worsening LVIDs, LVPWs, FS, and EF seen immediately after the procedure suggests that BAS causes altered loading conditions affecting LV function in pediatric patients with dilated cardiomyopathy requiring ECMO.

4.
Arch Gynecol Obstet ; 309(4): 1353-1367, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36971845

RESUMEN

OBJECTIVE: Restrictive foramen ovale (FO) in dextro-transposition of the great arteries (d-TGA) with intact ventricular septum may lead to severe life-threatening hypoxia within the first hours of life, making urgent balloon atrial septostomy (BAS) inevitable. Reliable prenatal prediction of restrictive FO is crucial in these cases. However, current prenatal echocardiographic markers show low predictive value, and prenatal prediction often fails with fatal consequences for a subset of newborns. In this study, we described our experience and aimed to identify reliable predictive markers for BAS. METHODS: We included 45 fetuses with isolated d-TGA that were diagnosed and delivered between 2010 and 2022 in two large German tertiary referral centers. Inclusion criteria were the availability of former prenatal ultrasound reports, of stored echocardiographic videos and still images, which had to be obtained within the last 14 days prior to delivery and that were of sufficient quality for retrospective re-analysis. Cardiac parameters were retrospectively assessed and their predictive value was evaluated. RESULTS: Among the 45 included fetuses with d-TGA, 22 neonates had restrictive FO postnatally and required urgent BAS within the first 24 h of life. In contrast, 23 neonates had normal FO anatomy, but 4 of them unexpectedly showed inadequate interatrial mixing despite their normal FO anatomy, rapidly developed hypoxia and also required urgent BAS ('bad mixer'). Overall, 26 (58%) neonates required urgent BAS, whereas 19 (42%) achieved good O2 saturation and did not undergo urgent BAS. In the former prenatal ultrasound reports, restrictive FO with subsequent urgent BAS was correctly predicted in 11 of 22 cases (50% sensitivity), whereas a normal FO anatomy was correctly predicted in 19 of 23 cases (83% specificity). After current re-analysis of the stored videos and images, we identified three highly significant markers for restrictive FO: a FO diameter < 7 mm (p < 0.01), a fixed (p = 0.035) and a hypermobile (p = 0.014) FO flap. The maximum systolic flow velocities in the pulmonary veins were also significantly increased in restrictive FO (p = 0.021), but no cut-off value to reliably predict restrictive FO could be identified. If the above markers are applied, all 22 cases with restrictive FO and all 23 cases with normal FO anatomy could correctly be predicted (100% positive predictive value). Correct prediction of urgent BAS also succeeded in all 22 cases with restrictive FO (100% PPV), but naturally failed in 4 of the 23 cases with correctly predicted normal FO ('bad mixer') (82.6% negative predictive value). CONCLUSION: Precise assessment of FO size and FO flap motility allows a reliable prenatal prediction of both restrictive and normal FO anatomy postnatally. Prediction of likelihood of urgent BAS also succeeds reliably in all fetuses with restrictive FO, but identification of the small subset of fetuses that also requires urgent BAS despite their normal FO anatomy fails, because the ability of sufficient postnatal interatrial mixing cannot be predicted prenatally. Therefore, all fetuses with prenatally diagnosed d-TGA should always be delivered in a tertiary center with cardiac catheter stand-by, allowing BAS within the first 24 h after birth, regardless of their predicted FO anatomy.


Asunto(s)
Foramen Oval , Transposición de los Grandes Vasos , Embarazo , Femenino , Recién Nacido , Humanos , Foramen Oval/diagnóstico por imagen , Foramen Oval/cirugía , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Estudios Retrospectivos , Ultrasonografía Prenatal/métodos , Feto , Arterias , Hipoxia
5.
Ultrasound Obstet Gynecol ; 62(3): 414-421, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37021693

RESUMEN

OBJECTIVES: Literature on cerebroplacental hemodynamics in fetuses with transposition of the great arteries (TGA) is scarce and provides conflicting results regarding the presence of a brain-sparing effect. The aims of this study were to examine Doppler parameters in the middle cerebral artery (MCA) and umbilical artery (UA) in a large cohort of fetuses with TGA, and to assess their possible utility in predicting the need for urgent balloon atrial septostomy (BAS) in the neonate. METHODS: This was a retrospective observational study of fetuses diagnosed with TGA between 2008 and 2022 and an age-matched cohort of normal fetuses, conducted in a single tertiary fetal cardiology center. Medical records and echocardiographic examinations were reviewed to collect demographic, sonographic and follow-up data. Selected Doppler parameters were compared between fetuses with TGA and normal fetuses, as well as between TGA fetuses with and those without an associated ventricular septal defect (VSD), to assess the impact of this congenital heart defect on cerebroplacental circulation. Additionally, Doppler indices in patients with a restrictive foramen ovale (FO) were analyzed to identify potential predictors of the need for urgent BAS. RESULTS: A total of 541 examinations of 159 fetuses with TGA performed between 19 and 40 weeks' gestation and 1300 examinations of 1215 age-matched normal fetuses were included in the study. MCA pulsatility index (PI) and UA-PI followed expected trends throughout pregnancy, with slightly higher values observed in TGA fetuses, albeit within the limits for the normal population. Cerebroplacental ratio (CPR) values were similar in normal and TGA fetuses. The presence of a small VSD did not have a clinically significant impact on Doppler parameters. Peak systolic velocity (PSV) in the MCA increased gradually after 35 weeks' gestation, especially in fetuses that did not develop restriction of the FO after birth. MCA-PSV values below 1.16 multiples of the median measured at 38 weeks or later predicted the need for urgent BAS with 81.4% sensitivity and 52.4% specificity. CONCLUSIONS: MCA-PI, UA-PI and CPR values in fetuses with TGA usually fall within normal limits throughout pregnancy. The presence of a small VSD does not affect the Doppler parameters significantly. MCA-PSV increases in TGA fetuses after 35 weeks, and its value measured at the last prenatal examination (ideally after 37 weeks) may serve as an additional predictive factor for the need for urgent BAS. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Defectos del Tabique Interventricular , Transposición de los Grandes Vasos , Femenino , Recién Nacido , Embarazo , Humanos , Transposición de los Grandes Vasos/diagnóstico por imagen , Feto/diagnóstico por imagen , Hemodinámica , Edad Gestacional , Ultrasonografía Doppler , Ultrasonografía Prenatal/métodos , Arteria Cerebral Media/diagnóstico por imagen , Arterias Umbilicales/diagnóstico por imagen , Flujo Pulsátil
6.
Echocardiography ; 40(3): 204-216, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36734058

RESUMEN

INTRODUCTION: Speckle tracking analysis was used to evaluate right (RA) and left (LA) atria size, shape and contractility to create a probability calculator to identify fetuses at risk for urgent neonatal balloon atrial septostomy (BAS). METHODS: The study group consisted of 39 fetuses with D-TGA, of which 55% (N = 22) required neonatal BAS and 45% (N = 17) did not. The RA and LA end-diastolic areas, lengths, widths, and sphericity indices as well as global, longitudinal, and transverse contractility were measured with speckle tracking analysis. The z-scores of the measurements were compared to 200 controls. Logistic regression analysis of the computed z-score measurements was performed to separate fetuses requiring urgent neonatal atrial BAS from those who did not. RESULTS: The following z-score values for all fetuses with D-TGA, irrespective of whether they required neonatal BAS, that were significantly less than controls: RA base sphericity index, basal-apical length fractional shortening, fractional area change, lateral wall annular plane systolic excursion (APSE), and longitudinal reservoir strain; LA mid-chamber width, fractional shortening, ejection fraction, basal-apical length fractional shortening, atrial ejection volume, septal wall APSE, and reservoir strain. The following z-score values were significantly larger than control values: RA/LA mid-chamber width, RA/LA base width, and RA mid-chamber length. Logistic regression analysis identified the following five measurements that correctly identified 19 of 22 fetuses requiring urgent neonatal atrial BAS with a sensitivity of 86.4%, a false-positive rate of 11.8% and a positive predictive value of 90.4%: (1) LA mid-chamber transverse fractional shortening, (2) RA mid-chamber end-diastolic width, (3) RA basal-apical length fractional shortening, (4) RA mid-chamber fractional shortening, and (5) RA fractional area change. CONCLUSION: Using the measurements described in this study identified significant differences between all fetuses with D-TGA and controls, as well as identified measurements that predicted the probability of D-TGA fetuses requiring neonatal septostomy.


Asunto(s)
Fibrilación Atrial , Transposición de los Grandes Vasos , Recién Nacido , Femenino , Embarazo , Humanos , Ecocardiografía , Ultrasonografía Prenatal , Corazón Fetal/diagnóstico por imagen , Arterias
7.
Pediatr Cardiol ; 44(6): 1333-1341, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36565310

RESUMEN

Patients with d-looped transposition of the great arteries (d-TGA), especially those without an adequate atrial septal defect, can experience severe hypoxemia and hemodynamic compromise in the neonatal period. This can be mitigated by urgent balloon atrial septostomy (BAS). However, some patients with d-TGA are born at centers without this capability. The aim of this retrospective study of d-TGA patients who had urgent or emergent BAS at our institution between 2010 and 2021 was to evaluate time from birth to BAS for infants born at a tertiary care center as compared to those requiring transport from other institutions and to examine correlation between time to BAS and patient outcomes. Our primary outcome was time from birth to BAS. Secondary outcomes included hospital and ICU length of stay, mortality, and evidence of pulmonary or neurologic abnormalities including pulmonary hypertension, abnormal neuroimaging, or seizures. Of 96 patients, 67 (70%) were born at our institution. The median time to BAS was 4 h for patients born at our institution vs. 14.1 h for those born elsewhere (p < .0001). A longer time from birth to BAS was associated with longer ICU (r = 0.21, p = 0.046) and hospital length of stay (r = 0.24, p = 0.02) and increased likelihood of elevated right ventricular pressure on post-operative discharge echocardiogram (p = 0.01). There were no differences in mortality between the groups. Therefore, prenatal planning for patients with known d-TGA should include a delivery plan with access to urgent BAS.


Asunto(s)
Fibrilación Atrial , Defectos del Tabique Interatrial , Transposición de los Grandes Vasos , Lactante , Recién Nacido , Embarazo , Femenino , Humanos , Transposición de los Grandes Vasos/cirugía , Estudios Retrospectivos , Cateterismo/métodos , Fibrilación Atrial/complicaciones , Defectos del Tabique Interatrial/complicaciones
8.
Pediatr Cardiol ; 44(6): 1382-1396, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36853336

RESUMEN

INTRODUCTION: Speckle tracking analysis of the endocardium of the right (RV) and left (LV) ventricles was used to evaluate the size, shape, and contractility of these chambers in fetuses with D-Transposition of the great arteries (D-TGA) to identify fetuses that would require emergent balloon atrial septostomy (BAS) after birth. METHODS: This was a retrospective analysis of fetuses with D-TGA and intact ventricular septum that were divided into 2 groups. Group 1 underwent urgent BAS after birth because of a restrictive atrial septum and group 2 did not. Using speckle tracking analysis, the end-diastolic and end-systolic RV and LV areas, lengths, widths, sphericity indices, and contractility were computed. Logistic regression analysis was performed to identify fetuses who would require urgent neonatal BAS. RESULTS: Of the 39 fetuses with D-TGA, 55% (n = 22) required urgent neonatal BAS (group 1) and 45% (n = 17) (group 2) did not. When comparing D-TGA groups 1 and 2, differences were seen in RV and LV area, sphericity index for segment 1 of the LV, LV fractional area of change and free wall annular plane systolic excursion, fractional shortening for LV segment 12, and RV free wall strain. Regression analysis of these measurements identified 91% of neonates who underwent BAS, with a false-positive rate of 12%. CONCLUSION: Using speckle tracking analysis to evaluate the RV and LV, measurable differences were identified for the RV and LV size, shape, and contractility between fetuses who underwent neonatal urgent BAS vs. those who did not require this procedure.


Asunto(s)
Fibrilación Atrial , Transposición de los Grandes Vasos , Recién Nacido , Humanos , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Ecocardiografía/métodos , Estudios Retrospectivos , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/cirugía
9.
Cardiol Young ; 33(12): 2654-2656, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37622316

RESUMEN

Atrioseptostomy balloon catheter is an essential item to have on our shelves. However, the recall and shortage in production of the commonly used balloon atrioseptostomy catheters posed an imminent threat to our patients. Herein, we present the case of a newborn with a post-natal diagnosis of simple transposition of great arteries and restrictive atrial communication where repeated static balloon atrial septostomy using a 9 mm x 20 mm Sterling balloon failed to improve his status. We had to improvise per-operatively a new bespoke technique to perform a vital pull-through balloon atrial septostomy. The distal third of a 10 mm x 20 mm semi-compliant Cristal balloon was exteriorised out the tip of a 6-Fr 55 cm Cook Flexor sheath in the left atrium, and both were simultaneously pulled back to the right atrium to create an 8 mm septal defect. The procedure was successful without any complications. The baby was weaned off prostaglandin on day 3 and surgically repaired on day 5 with excellent results.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Defectos del Tabique Interatrial , Transposición de los Grandes Vasos , Lactante , Recién Nacido , Humanos , Defectos del Tabique Interatrial/cirugía , Atrios Cardíacos/cirugía , Pericardiectomía , Catéteres
10.
Perfusion ; : 2676591231220816, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38053305

RESUMEN

INTRODUCTION: In children with myocarditis or dilated cardiomyopathy (DCM) on extracorporeal membrane oxygenation (ECMO) for cardiogenic shock, it is often necessary to decompress the left heart to minimize distension and promote myocardial recovery. We compare outcomes in those who underwent balloon atrial septostomy (BAS) versus direct left atrial (LA) drainage for left heart decompression in this population. METHODS: Retrospective study of the Extracorporeal Life Support Organization (ELSO) multicenter registry of patients ≤ 18 years with myocarditis or DCM on ECMO who underwent LA decompression. Descriptive and univariate statistics assessed association of patient factors with decompression type. Multivariable logistic regression sought independent associations with outcomes. RESULTS: 369 pediatric ECMO runs were identified. 52% myocarditis, 48% DCM, overall survival 74%. 65% underwent BAS and 35% LA drainage. Patient demographics including age, weight, gender, race/ethnicity, diagnosis, pre-ECMO pH, mean airway pressure, and arrest status were similar. 89% in the BAS group were peripherally cannulated onto ECMO, versus 3% in the LA drainage group (p < .001). On multivariable analysis, LA drainage (OR 3.96; 95% CI, 1.47-10.711; p = .007), renal complication (OR 2.37; 95% CI, 1.41-4.01; p = .001), cardiac complication (OR 3.14; 95% CI, 1.70-5.82; p < .001), and non-white race/ethnicity (OR 1.75; 95% CI, 1.04-2.94; p = .035) were associated with greater odds of mortality. There was a trend toward more episodes of pulmonary hemorrhage in BAS (n = 17) versus LA drainage group (n = 3), p = .08. Comparing only those with central cannulation, LA drainage group was more likely to be discontinued from ECMO due to recovery (72%) versus the BAS group (48%), p = .032. CONCLUSIONS: In children with myocarditis or DCM, there was a three times greater likelihood for mortality with LA drainage versus BAS for LA decompression. When adjusted for central cannulation groups only, there was better recovery in the LA drainage group and no difference in mortality. Further prospective evaluation is warranted.

11.
Circ J ; 86(12): 1990-1997, 2022 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-36047087

RESUMEN

BACKGROUND: Balloon atrial septostomy (BAS) is an essential catheterization procedure for congenital heart lesions. Recently, a balloon catheter for static BAS was approved for the first time in Japan as an alternative to the conventional pull-through BAS. Despite the expected increase in the use of static BAS, reports on its safety are scarce worldwide.Methods and Results: Data on static and pull-through BAS registered in a national registry between 2016 and 2018 were collected. During the study period, 247 sessions of static BAS and 588 sessions of pull-through BAS were performed on a total of 674 patients. Patients who underwent static BAS were older (P<0.001). The incidence of serious adverse events (4.3% vs. 0.9%, P=0.03) and the overall incidence of adverse events (8.1% vs. 3.2%, P=0.03) were higher in static BAS than in pull-through BAS. Among patients who underwent static BAS, the risk factor for adverse events was a body weight <3 kg at the time of the procedure (odds ratio: 4.3 [confidence interval: 1.7-11], P=0.003). CONCLUSIONS: This nationwide study revealed differences in patient background between static and pull-through BAS, as well as a higher incidence of adverse events related to static BAS. Patients weighing <3 kg are at high risk for adverse events after static BAS and may require surgical and circulatory support backup.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Transposición de los Grandes Vasos , Humanos , Procedimientos Quirúrgicos Cardíacos/métodos , Cateterismo/efectos adversos , Factores de Riesgo , Oportunidad Relativa , Sistema de Registros , Transposición de los Grandes Vasos/epidemiología , Transposición de los Grandes Vasos/etiología , Transposición de los Grandes Vasos/cirugía
12.
Cardiol Young ; 32(1): 130-131, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34210380

RESUMEN

Balloon atrial septostomy is a palliative procedure that is performed in D-transposition of great arteries when surgery is not immediately available. Although D-TGA and left isomerism association are rare, it is an important condition as the BAS procedure approach is unique. In this case report, we present two cases of D-TGA with left isomerism where BAS was performed due to restrictive atrial septal defect and lack of immediate availability of the paediatric cardiac surgeon.


Asunto(s)
Síndrome de Heterotaxia , Procedimientos Quirúrgicos Torácicos , Transposición de los Grandes Vasos , Vena Ácigos/diagnóstico por imagen , Vena Ácigos/cirugía , Niño , Síndrome de Heterotaxia/cirugía , Humanos , Pericardiectomía , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía
13.
Cardiol Young ; 32(2): 328-330, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34304749

RESUMEN

We describe a 3-month-old infant with transposition of great arteries and restrictive foramen ovale who presented with severe cyanosis. Child had a large thrombus causing near-total occlusion of the inferior caval vein. An emergency atrial septoplasty was performed via internal jugular venous access. The case emphasises the technical challenges faced while performing this procedure through jugular approach and plausible solutions to overcome these challenges.


Asunto(s)
Foramen Oval , Situs Inversus , Transposición de los Grandes Vasos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Lactante , Venas Yugulares/diagnóstico por imagen , Venas Yugulares/cirugía , Transposición de los Grandes Vasos/cirugía
14.
J Card Fail ; 27(4): 501-504, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33358956

RESUMEN

BACKGROUND: This study describes the authors' experience with a limited balloon atrial septostomy technique, using a median balloon size of 15 mm, as a left ventricular (LV) unloading strategy in venoarterial extracorporeal membrane oxygenation (VA-ECMO). There has been increasing use of VA-ECMO in cardiogenic shock. Although LV unloading strategies have been suggested to improve outcomes, it is unclear which strategy is optimal. METHODS AND RESULTS: We performed a retrospective study of patients who underwent a limited balloon atrial septostomy for LV unloading in peripheral VA-ECMO at a single center. The goal of this study was to define the procedural outcomes and clinical characteristics of these patients. Of the 12 patients identified, none had complications related to the procedure. There was a significant decrease in the mean left atrial pressure and the majority of patients had radiologic improvement in pulmonary vascular congestion. Of the 12 patients, 58.3% survived to discharge. CONCLUSIONS: Limited BAS is an elegant and safe method for unloading the LV in peripheral VA-ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Humanos , Estudios Retrospectivos , Choque Cardiogénico/cirugía
15.
Ultrasound Obstet Gynecol ; 57(5): 756-768, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32730671

RESUMEN

OBJECTIVES: To investigate the impact of abnormal perinatal loading conditions on cardiac geometry and function in term fetuses and neonates with transposition of the great arteries with intact interventricular septum (simple TGA), and to explore the predictive value of fetal cardiac parameters for an urgent balloon atrial septostomy (BAS) after birth. METHODS: This was a prospective longitudinal follow-up study of women delivering at term, including both uncomplicated pregnancies with normal outcome and pregnancies affected by fetal simple TGA. Conventional, spectral-tissue Doppler and speckle-tracking echocardiographic parameters were obtained within 1 week before delivery and within the first few hours after delivery. Neonates with simple TGA that required urgent BAS were assessed after the procedure and before corrective arterial switch surgery. Cardiac parameters were normalized by cardiac cycle length, ventricular end-diastolic length or end-diastolic dimension, as appropriate. Fetal and neonatal cardiac parameters were compared between simple-TGA cases and controls, and perinatal changes in the simple-TGA group were assessed. Receiver-operating-characteristics (ROC)-curve analysis was used to assess the predictive value of fetal cardiac parameters for urgent BAS after birth in the simple-TGA group. RESULTS: A total of 67 pregnant women delivering at term were included in the study (54 normal pregnancies and 13 with a diagnosis of fetal simple TGA). Compared with normal term fetuses, term fetuses with simple TGA exhibited more globular hypertrophied ventricles, increased biventricular systolic function and diastolic dysfunction (right ventricular (RV) sphericity index (SI), 0.58 vs 0.54; left ventricular (LV)-SI, 0.55 vs 0.49; combined cardiac output (CCO), 483 vs 406 mL/min/kg; LV torsion, 4.3 vs 3.0 deg/cm; RV isovolumetric relaxation time (IVRT'), 127 vs 102 ms; P < 0.01 for all). Compared with normal neonates, neonates with simple TGA demonstrated biventricular hypertrophy, a more spherical right ventricle and altered systolic and diastolic functional parameters (RV-SI, 0.61 vs 0.43; RV myocardial performance index, 0.47 vs 0.34; CCO, 697 vs 486 mL/min/kg; LV-IVRT', 100 vs 79 ms; RV-IVRT', 106 vs 71 ms; P < 0.001 for all). Paired comparison of neonatal and fetal cardiac indices in the simple-TGA group showed persistence of the fetal phenotype, increased biventricular systolic myocardial contractility and CCO, and diastolic dysfunction (RV systolic myocardial velocity (S'), 0.31 vs 0.24 cm/s; LV-S', 0.23 vs 0.18 cm/s; CCO, 697 vs 483 mL/min/kg; LV torsion, 1.1 vs 4.3 deg/cm; P < 0.001 for all). Several fetal cardiac parameters in term fetuses with simple TGA demonstrated high predictive value for an urgent BAS procedure after birth. Our proposed novel fetal cardiac index, LV rotation-to-shortening ratio, as a potential marker of subendocardial dysfunction, for a cut-off value of ≥ 0.23, had an area under the ROC curve (AUC) of 0.94, sensitivity of 100% and specificity of 83%. For RV/LV end-diastolic area ratio ≥ 1.33, pulmonary-valve-to-aortic-valve-dimension ratio ≤ 0.89, RV/LV cardiac output ratio ≥ 1.38 and foramen-ovale-dimension-to-total-interatrial-septal-length ratio ≤ 0.27, AUC was 0.93-0.98, sensitivity was 86% and specificity was 83-100% for all. CONCLUSIONS: Simple-TGA fetuses exhibited cardiac remodeling at term with more profound alterations in these cardiac parameters after birth, suggestive of adaptation to abnormal loading conditions and possible adaptive responses to hypoxemia. Perinatal adaptation in simple TGA might reflect persistence of the abnormal parallel arrangement of cardiovascular circulation and the presence of widely patent fetal shunts imposing volume load on the neonatal heart. The fetal cardiac parameters that showed high predictive value for urgent BAS after birth might reflect the impact of late-gestation pathophysiology and progressive hypoxemia on fetal cardiac geometry and function in simple TGA. If these findings are validated in larger prospective studies, detailed cardiac assessment of fetuses with simple TGA near term could facilitate improvements in perinatal management and refinement of the timing of postnatal intervention strategies to prevent adverse pregnancy outcomes. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Asunto(s)
Cateterismo Cardíaco/métodos , Ecocardiografía/métodos , Corazón Fetal/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Ultrasonografía Prenatal/métodos , Adulto , Tabique Interatrial/embriología , Tabique Interatrial/fisiopatología , Tabique Interatrial/cirugía , Gasto Cardíaco , Femenino , Corazón Fetal/embriología , Corazón Fetal/fisiopatología , Estudios de Seguimiento , Foramen Oval/diagnóstico por imagen , Foramen Oval/embriología , Foramen Oval/fisiopatología , Humanos , Recién Nacido , Estudios Longitudinales , Masculino , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/embriología
16.
Pediatr Cardiol ; 42(3): 597-605, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33492430

RESUMEN

Once a mainstay in the treatment of neonates with d-transposition of the great arteries (d-TGA), the application of balloon atrial septostomy (BAS) in the d-TGA population has become more selective. Currently, there is no clear evidence for or against a selective BAS strategy. The aims of this single-center retrospective study were to determine the incidence of BAS in the neonatal d-TGA population in the current era, to measure the rate of procedural success, and to compare the outcomes and complication rates of patients who underwent BAS to those who underwent neonatal ASO alone. Between 2012 and 2018, 147 patients with d-TGA underwent initial medical management and ASO, 73 of which underwent BAS. The percentage of patients that underwent BAS decreased from 73 to 33% over the study time period. In patients with d-TGA with intact ventricular septum, 33% of patients remained off of PGE1 at the time of surgery regardless of BAS. In d-TGA with ventricular septal defect, 85.7% of those that underwent BAS and 54.1% of those who did not remained off of PGE1 at the time of surgery, however, this difference did not reach statistical significance. In this single institution retrospective cohort of patients with d-TGA, the performance of a technically successful balloon atrial septostomy did not eliminate the need for PGE1 therapy at the time of definitive ASO. This was true regardless of the presence or absence of a ventricular septal defect.


Asunto(s)
Tabique Interatrial/cirugía , Transposición de los Grandes Vasos/cirugía , Alprostadil/uso terapéutico , Operación de Switch Arterial , Estudios de Casos y Controles , Femenino , Humanos , Recién Nacido , Masculino , Estudios Retrospectivos , Transposición de los Grandes Vasos/tratamiento farmacológico
17.
Pediatr Cardiol ; 42(7): 1575-1584, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34052858

RESUMEN

Critical hypoxemia soon after birth is the most critical preoperative determinant of neurological outcomes and survival in newborns with Dextro Transposition of the Great Arteries and Intact Ventricular Septum (D-TGAIVS). Our study aimed to define fetal echocardiographic aspects that can better predict neonates with D-TGAIVS at risk for restricted interatrial communication after birth. 31 fetuses with a prenatal diagnosis of D-TGAIVS were included in our study. We divided patients with D-TGAIVS according to the timing of balloon atrial septostomy: Urgent, Not-Urgent and no BAS. We identified five fetal echocardiographic aspects of the interatrial septum (redundant, aneurysmal, flat, fixed, hypermobile). No significant differences in these fetal echocardiographic features were found between the three different groups of D-TGAIVS according to the timing of balloon atrial septostmy. However, only two patients showed flat appearance of interatrial communication: both needed Urgent balloon atrial septostomy. The prevalence of hypermobile septum primum was significantly lower in the control group compared to patients with D-TGAIVS. Fetal echocardiographic aspects cannot predict patients with D-TGAIVS who will not need Urgent balloon atrial septostomy. Therefore, we recommended a delivery in a tertiary center, equipped for Urgent balloon atrial septostomy, for all patients with D-TGAIVS regardless of fetal echocardiographic features.


Asunto(s)
Transposición de los Grandes Vasos , Tabique Interventricular , Arterias , Ecocardiografía , Femenino , Humanos , Hipoxia , Recién Nacido , Embarazo , Reproducibilidad de los Resultados , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía , Tabique Interventricular/diagnóstico por imagen
18.
Cardiol Young ; 31(10): 1613-1618, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33641693

RESUMEN

INTRODUCTION: Many newborns with pulmonary atresia/intact ventricular septum require intervention to establish pulmonary flow and sufficient cardiac output. The resulting haemodynamic changes are not well characterised and may have unintended consequences. METHODS: This is a 30-year (1988-2018) retrospective study of patients with pulmonary atresia intact ventricular septum. RESULTS: Eighty-nine patients were included, and median follow-up was 8 years. Fifty-five per cent had coronary sinusoids and 27% had right ventricular-dependent coronary circulation. Most patients were managed with surgical aortopulmonary or modified Blalock-Taussig shunt (73%), and 12 patients underwent balloon atrial septostomy before surgical intervention. The remaining patients (27%) underwent only transcatheter interventions; 7 required an atrial septostomy and 17 required ductal stentings. All-cause mortality was 10%, most deaths (89%) occurred before 18 months of age. Of these early deaths, 87% required a balloon atrial septostomy and 85% had right ventricular-dependent coronary sinusoids. Eighteen-month mortality was significantly higher for patients who required a balloon atrial septostomy compared to those who did not (36% versus 1.4% p < 0.0001). DISCUSSION: Patients with pulmonary atresia/intact ventricular septum who require balloon atrial septostomy in the newborn period have significantly higher 18-month mortality. Quantifying the mortality difference may help guide prognostication and expectation setting. Infants who had septostomy and a surgical shunt in the newborn period fared better than those who only underwent septostomy (even when accompanied by ductal stenting). For infants with right ventricular-dependent circulation, atrial septostomy should only be performed on an urgent or emergent basis and these patients should be considered for early surgical intervention and neonatal transplant.


Asunto(s)
Cardiopatías Congénitas , Atresia Pulmonar , Tabique Interventricular , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Recién Nacido , Atresia Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/cirugía
19.
Cardiol Young ; 31(5): 867-869, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33507139

RESUMEN

There has been an increase in the use of extracorporeal membrane oxygenation for severe neonatal cardiac failure. However, the frequency of complications is high, particularly in preterm and low-birth-weight neonates. Herein, we present combination treatment with transcatheter balloon atrioseptostomy and bilateral pulmonary artery banding in a collapsed preterm neonate. This strategy can be an alternative to circulatory support using extracorporeal membrane oxygenation.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Procedimientos Quirúrgicos Torácicos , Humanos , Recién Nacido , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares
20.
Prog Pediatr Cardiol ; 60: 101265, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32837147

RESUMEN

The current pandemic has driven the medical community to adapt quickly to unprecedented challenges. Among these challenges is the need to minimize staff exposure to COVID-19 during neonatal cardiac procedures. In this report, we describe measures we have taken to protect health care workers while ensuring successful outcomes. These measures include wearing appropriate personal protective equipment, physical distancing, designating separate delivery and transport teams, and limiting the number of providers in direct contact with any patient who is infected or whose infection status is unknown. LEARNING OBJECTIVES: 1.To understand specific challenges caused by the COVID-19 pandemic for patients with congenital heart disease needing urgent neonatal intervention.2.To recognize measures that can be taken to minimize health care workers' exposures to the virus during high-risk neonatal cardiac procedures.3.To review the management of neonates with d-transposition of the great arteries and inadequate mixing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA