Crit Rev Clin Lab Sci ; : 1-11, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38572824

RESUMEN

Data and results from interlaboratory comparison (ILC) studies, external quality assessment (EQA) and proficiency testing (PT) activities are important and valuable contributions both to the further development of all disciplines of medical laboratory diagnostics, and to the evaluation and comparison of in vitro diagnostic assays. So far, however, there are no recommendations as to which essential items should be addressed in publications on interlaboratory comparisons. The European Organization of External Quality Assurance Providers in Laboratory Medicine (EQALM) recognized the need for such recommendations, and these were developed by a group of experts. The result of this endeavor is the EQALM Statement on items recommended to be addressed in publications on interlaboratory comparison activities (PubILC), in conjunction with a user-friendly checklist. Once adopted by authors and journals, the EQALM Statement will ensure essential information and/or study-related facts are included within publications on EQA/PT activities.

2.
Eur J Clin Microbiol Infect Dis ; 43(8): 1597-1607, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38833104

RESUMEN

PURPOSE: To comprehensively investigate the diagnostic performance of routinely used assays in MPXV testing, the National Center of Clinical Laboratories in China conducted a nationwide external quality assessment (EQA) scheme and an evaluated nine assays used by ≥ 5 laboratories in the EQA. METHODS: MPXV virus-like particles with 2700, 900 and 300 copies/mL were distributed to 195 EQA laboratories. For extended analysis, triple-diluted samples from 9000 to 4.12 copies/mL were repeated 20 times using the assays employed by ≥ 5 laboratories. The diagnostic performance was assessed by analyzing EQA data and calculating the limits of detection (LODs). RESULTS: The performance was competent in 87.69% (171/195) of the participants and 87.94% (175/199) of the datasets. The positive percentage agreements (PPAs) were greater than 99% for samples at 2700 and 900 copies/mL, and 95.60% (761/796) for samples at 300 copies/mL. The calculated LODs for the two clades ranged from 228.44 to 924.31 copies/mL and were greater than the LODs specified by the respective kits. EasyDiagnosis had the lowest calculated LODs and showed superior performance in EQA, whereas BioGerm and Sansure, with higher calculated LODs, did not perform well in EQA. CONCLUSION: This study provides valuable information from the EQA data and evaluation of the diagnostic performance of MPXV detection assays. It also provided insights into reagent optimization and enabled prompt public health interventions for the outbreak.


Asunto(s)
Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , China/epidemiología , Límite de Detección , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Monkeypox virus/genética , Monkeypox virus/aislamiento & purificación
3.
BMC Infect Dis ; 24(1): 646, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937708

RESUMEN

INTRODUCTION: When COVID-19 hit the world in 2019, an enhanced focus on diagnostic testing for SARS-CoV-2 was essential for a successful pandemic response. Testing laboratories stretched their capabilities for the new coronavirus by adopting different test methods. The necessity of having external quality assurance (EQA) mechanisms was even more critical due to this rapid expansion. However, there was a lack of experience in providing the necessary SARS-CoV-2 EQA materials, especially in locations with constrained resources. OBJECTIVE: We aimed to create a PT (Proficiency testing) programme based on the Dried Tube Specimens (DTS) method that would be a practical option for molecular based SARS-CoV-2 EQA in Low- and Middle-Income Countries. METHODS: Based on previous ISO/IEC 17043:2010 accreditation experiences and with assistance from the US Centers for Disease Control and Prevention, The Supranational Reference Laboratory of Uganda (adapted the DTS sample preparation method and completed a pilot EQA program between 2020 and 2021. Stability and panel validation testing was conducted on the designed materials before shipping to pilot participants in six African countries. Participants received a panel containing five SARS-CoV-2 DTS samples, transported at ambient conditions. Results submitted by participants were compared to validation results. Participants were graded as satisfactory (≥ 80%) or unsatisfactory (< 80%) and performance reports disseminated. RESULTS: Our SARS-CoV-2 stability experiments showed that SARS-CoV-2 RNA was stable (-15 to -25 °C, 4 to 8 °C, (18 to 28 °C) room temperature and 35 to 38 °C) as well as DTS panels (4 to 8 °C, 18 to 28 °C, 35 to 38 °C and 45 °C) for a period of 4 weeks. The SARS-CoV-2 DTS panels were successfully piloted in 35 test sites from Zambia, Malawi, Mozambique, Nigeria, and Seychelles. The pilot results of the participants showed good accuracy, with an average of 86% (30/35) concordance with the original SARS CoV-2 expectations. CONCLUSION: The SARS-CoV-2 DTS PT panel is reliable, stable at ambient temperature, simple to prepare and requires minimal resources.


Asunto(s)
COVID-19 , Países en Desarrollo , Ensayos de Aptitud de Laboratorios , SARS-CoV-2 , Manejo de Especímenes , Humanos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Manejo de Especímenes/métodos , Manejo de Especímenes/normas , Prueba de COVID-19/métodos , Uganda , Proyectos Piloto
4.
Clin Chem Lab Med ; 62(11): 2198-2204, 2024 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-38727000

RESUMEN

OBJECTIVES: Italy legalized cannabis oil for specific medical conditions (neuropathic pain, refractory epilepsy and other established pathologies) in 2015, but mandates titration of principal cannabinoids before marketing each batch using iphenated techniques coupled with mass spectrometry. To assess reliability of laboratories from the Italian National Health Service in charge of titrating the batches, the Italian National Institute of Health set up an quality control program on determination of Δ9-tetrahydrocannabinol l (THC), cannabidiol (CBD), Δ9-tetrahydrocannabinolic acid A (THCA-A) and cannabidiolic acid (CBDA) in cannabis oil preparations. METHODS: Two rounds of exercises have been carried out since 2019, involving sixteen Italian laboratories. Five different cannabis oil samples (19-1A and 19-1B for the first round and 22-1A, 22-1B and 22-1C for the second one were prepared and 1 mL amount of each sample was sent to the laboratories. The quantitative performance of each laboratory was assessed calculating the Z-score value, a statistical measurement for value's relationship to the mean of a group of values. RESULTS: In the first round, eight out of fourteen laboratories employed an LC-MS while the remaining six used GC-MS. Differently, in the second round, six out of eleven laboratories employed a GC-MS while the remaining five used LC-MS. In the first round, only 28.6 % laboratories achieved an acceptable performance (Z-score±2), and all of them used LC-MS as analytical method. In the second round, none of the laboratories achieved an acceptable performance. Satisfactory results, based on Z-scores, were generally low (0.0-75.0 %), with only one exception of 100 % for THCA-A determination in sample 22-1B. In the second round, three false negatives (two THC and one CBD by GC-MS determination) were reported while no false positives were described in the blank sample. The two rounds yielded a mean ERR% of 42 % approximately and a mean CV% around 70 % in GC-MS determination. When applying LC-MS determination, the two rounds yielded a mean ERR% of 36 % approximately and a mean CV% around 33 %. CONCLUSIONS: The obtained results underline the need for a clear and consistent protocol to be adopted by all laboratories intending to include the titration of oily cannabis-based products into their routinely analytical techniques. This emphasis on methodology standardization and participation to quality control schemes is essential for ensuring reliable and accurate measurements, ultimately enhancing the overall effectiveness and reliability of medical cannabis treatments.


Asunto(s)
Cannabinoides , Control de Calidad , Italia , Cannabinoides/análisis , Cannabinoides/normas , Dronabinol/análisis , Dronabinol/análogos & derivados , Humanos , Aceites de Plantas/análisis , Aceites de Plantas/química , Aceites de Plantas/normas , Cannabis/química , Cannabidiol/análisis , Cromatografía de Gases y Espectrometría de Masas/normas , Reproducibilidad de los Resultados
5.
Clin Chem Lab Med ; 62(10): 1991-2000, 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-38456798

RESUMEN

OBJECTIVES: Early diagnosis of inborn errors of metabolism (IEM) is crucial to ensure early detection of conditions which are treatable. This study reports on targeted metabolomic procedures for the diagnosis of IEM of amino acids, acylcarnitines, creatine/guanidinoacetate, purines/pyrimidines and oligosaccharides, and describes its validation through external quality assessment schemes (EQA). METHODS: Analysis was performed on a Waters ACQUITY UPLC H-class system coupled to a Waters Xevo triple-quadrupole (TQD) mass spectrometer, operating in both positive and negative electrospray ionization mode. Chromatographic separation was performed on a CORTECS C18 column (2.1 × 150, 1.6 µm). Data were collected by multiple reaction monitoring. RESULTS: The internal and EQA results were generally adequate, with a few exceptions. We calculated the relative measurement error (RME) and only a few metabolites displayed a RME higher than 30 % (asparagine and some acylcarnitine species). For oligosaccharides, semi-quantitative analysis of an educational panel clearly identified the 8 different diseases included. CONCLUSIONS: Overall, we have validated our analytical system through an external quality control assessment. This validation will contribute to harmonization between laboratories, thus improving identification and management of patients with IEM.


Asunto(s)
Errores Innatos del Metabolismo , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Espectrometría de Masas en Tándem/normas , Errores Innatos del Metabolismo/diagnóstico , Cromatografía Líquida de Alta Presión/normas , Cromatografía Líquida de Alta Presión/métodos , Control de Calidad , Carnitina/análogos & derivados , Carnitina/análisis , Metabolómica/métodos
6.
Clin Chem Lab Med ; 62(9): 1824-1834, 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-38565134

RESUMEN

OBJECTIVES: Laboratories need to take into consideration the specificity and imprecision of assays not only in verification, but also of quality assessment. This study investigates the composition of serum used in EQA materials by comparing material from a single and multiple donors (pooled material), across multiple methods, using creatinine as an example. METHODS: Sixteen different serum matrices were distributed as 36 specimens through the UK NEQAS for Acute and Chronic Kidney Disease Scheme from March 2022 to March 2023. Male-only and female-only serum was used as single donations, pooled donations, unmanipulated or with added exogenous creatinine. Specimens were distributed to primarily UK participants (approximately n=500) for creatinine analysis. Data has been reviewed by method compared to the enzymatic creatinine method principle mean. RESULTS: From the 16 different matrices, only the enzymatic creatinine assay systems from Roche Cobas and Siemens Atellica met the minimum acceptable bias goal, from biological data, of 5.6 %, in all specimens. Pooled material showed less variation in bias across all methods. CONCLUSIONS: Since Laboratories invest a lot of time and money in quality management, they need to know the limitations of their assays so that they are not investigating 'apparent' EQA/IQC problems which are purely due to non-specific, imprecise assay, rather than an analytical issue in their laboratory. When large numbers of individual donations are combined, interferents are essentially diluted out. Therefore, if EQA material is of this type it will be very difficult to determine the actual assay's bias and variability.


Asunto(s)
Creatinina , Humanos , Creatinina/sangre , Masculino , Femenino , Control de Calidad
7.
Clin Chem Lab Med ; 62(1): 77-84, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-37470304

RESUMEN

OBJECTIVES: We report the results of glucose measurements performed during one year by the same measurement procedures (MPs) in 58 Norwegian hospital laboratories using control materials provided by external quality assessment (EQA) schemes from two different providers. The providers used materials with presumed vs. verified commutability and transfers of values using reference material vs. using a highest-order reference MP. METHODS: Data from six Labquality and three Noklus glucose EQA surveys were aggregated for each MP (Abbott Alinity, Abbott Architect, Roche Cobas, and Siemens Advia) in each scheme. For each EQA result, percent difference from target value (% bias) was calculated. Median percent bias for each MP per scheme was then calculated. RESULTS: The median % biases observed for each MP in the Labquality scheme were significantly larger than those in the Noklus scheme, which uses verified commutable control materials and highest-order reference MP target values. The difference ranged from 1.2 (Roche Cobas, 2.9 vs. 1.7 %) to 4.4 percentage points (Siemens Advia, 3.2 % vs. -1.2 %). The order of bias size for the various MPs was different in the two schemes. In contrast to the Labquality scheme, the median % biases observed in the Noklus scheme for Abbott Alinity (-0.1 %), Abbott Architect (-0.5 %), and Siemens Advia (-1.2 %) were not significantly different from target value (p>0.756). CONCLUSIONS: This study underlines the importance of using verified commutable EQA materials and target values traceable to reference MPs in EQA schemes designed for assessment of metrological traceability of laboratory results.


Asunto(s)
Laboratorios de Hospital , Laboratorios , Humanos , Control de Calidad , Glucosa , Sesgo , Valores de Referencia , Estándares de Referencia
8.
Clin Chem Lab Med ; 62(1): 67-76, 2024 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-37470745

RESUMEN

OBJECTIVES: This study aims to evaluate the commutability of external quality assessment (EQA) materials and candidate reference materials (RMs) for plasma renin activity (PRA) assay. METHODS: Commutabilities of 16 candidate RMs were measured along with 40 clinical samples by the four different routine PRA assays, including three LC‒MS/MS assays and one chemiluminescence immunoassay. Sixteen candidate RMs included native/spiked human plasma pools (small-scale pools with <50 individuals) and current EQA materials (large-scale pools with >1,000 individuals). Difference in bias approach and linear regression with prediction interval approach were adopted to determine the commutability. Two-way variance analysis was used to estimate the effects of spiked and pool size on the commutability. Stability and homogeneity studies were performed. RESULTS: Precision and correlation performance of all assays was acceptable. In the difference in bias approach, the commutability results were not satisfactory (noncommutability: 14/16) and significant sample-specific effects were detected in assay pairs using different incubation buffers. For the prediction interval approach, no commutability was observed in the spiked small-scale pools; EQA materials (4/9) had more satisfactory commutability among all assays than the small-scale pools (2/7); RMs of large-scale pools tend to have better commutability no matter spiked or not. CONCLUSIONS: Commutable RMs were obtainable but challenging. Current EQA materials with relatively good commutability, stability, and homogeneity were appropriate RMs. Large-scale pools are tending to be commutable. Spiking in small-scale pools was not suggested to prepare RMs. MPs adopting a uniform incubation buffer would be preferable for further commutability research.


Asunto(s)
Renina , Espectrometría de Masas en Tándem , Humanos , Estándares de Referencia , Cromatografía Liquida , Sesgo
9.
Clin Chem Lab Med ; 62(8): 1548-1556, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-38456711

RESUMEN

OBJECTIVES: The aim of this study is to develop a practical method for bivariate z-score analysis which can be applied to the survey of an external quality assessment programme. METHODS: To develop the bivariate z-score analysis, the results of four surveys of the international D-Dimer external quality assessment programme of 2022 of the ECAT Foundation were used. The proposed methodology starts by identifying the bivariate outliers, using a Supervised Sequential Hotelling T2 control chart. The outlying data are removed, and all the remaining data are used to provide robust estimates of the parameters of the assumed underlying bivariate normal distribution. Based on these estimates two nested homocentric ellipses are drawn, corresponding to confidence levels of 95 and 99.7 %. The bivariate z-score plot described provides the laboratory with an indication of both systematic and random deviations from zero z-score values. The bivariate z-score analysis was examined within survey 2022-D4 across the three most frequently used methods. RESULTS: The number of z-score pairs included varied between 830 and 857 and the number of bivariate outliers varied between 20 and 28. The correlation between the z-score pairs varied between 0.431 and 0.647. The correlation between the z-score pairs for the three most frequently used varied between 0.208 and 0.636. CONCLUSIONS: The use of the bivariate z-score analysis is of major importance when multiple samples are distributed around in the same survey and dependency of the results is likely. Important lessons can be drawn from the shape of the ellipse with respect to random and systematic deviations, while individual laboratories have been informed about their position in the state-of-the-art distribution and whether they have to deal with systematic and/or random deviations.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno , Control de Calidad , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Humanos , Consenso
10.
Clin Chem Lab Med ; 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39027966

RESUMEN

OBJECTIVES: This article defines analytical performance specifications (APS) for evaluating laboratory proficiency through an external quality assessment scheme. METHODS: Standard deviations for proficiency assessment were derived from Thompson's characteristic function applied to robust data calculated from participants' submissions in the Occupational and Environmental Laboratory Medicine (OELM) external quality assurance scheme for trace elements in serum, whole blood and urine. Characteristic function was based on two parameters: (1) ß - the average coefficient of variation (CV) at high sample concentrations; (2) α - the average standard deviation (SD) at low sample concentrations. APSs were defined as 1.65 standard deviations calculated by Thompson's approach. Comparison between OELM robust data and characteristic function were used to validate the model. RESULTS: Application of the characteristic function allowed calculated APS for 18 elements across three matrices. Some limitations were noted, particularly for elements (1) with no sample concentrations near analytical technique limit of detection; (2) exhibiting high robust CV at high concentration; (3) exhibiting high analytical variability such as whole blood Tl and urine Pb; (4) with an unbalanced number of robust SD above and under the characteristic function such as whole blood Mn and serum Al and Zn. CONCLUSIONS: The characteristic function was a useful means of deriving APS for trace elements in biological fluids where biological variation data or outcome studies were not available. However, OELM external quality assurance scheme data suggests that the characteristic functions are not appropriate for all elements.

11.
Clin Chem Lab Med ; 62(12): 2435-2443, 2024 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-39238208

RESUMEN

OBJECTIVES: This study aimed to assess the validity of external quality assessment (EQA) laboratory results across various cultural and environmental contexts and to identify potential improvement areas. METHODS: The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a 2-year study (2022 and 2023) in which EQA materials, related software and online training was provided by a commercial vendor to 100 laboratories in ten IFCC member society countries. The results were analysed on a monthly basis by the TF-GLQ, to show the number of submissions per country, tests per lab, acceptability rates, random failures and to get a measure of which analytes performed poorly. RESULTS: The EQA material was dispatched on a quarterly basis. Some countries had problems with customs releasing the material in a timely manner, resulting in laboratories not receiving them on time leading to no submission. We report here the results for the second year of the survey. The number of examinations varied between laboratories, ranging from seven to 84 analytes. Of the ten countries surveyed, six averaged greater than 90 % acceptable results over the whole 12-months cycle, one had unacceptable results for two of the nine months they returned results and the other four were considered to not perform to an acceptable standard. CONCLUSIONS: All 100 participating laboratories indicated satisfaction with the EQA survey and related services, including on-site training, and report handling. However, specimen receiving issues, suggest benefits in dispatching materials for a full 12-month cycle. Significant discrepancies in EQA performance indicate that four countries require long-term assistance, training and guidance. To ensure reliable patient results, promoting EQA in certain countries is essential to achieve the required level of quality.


Asunto(s)
Laboratorios Clínicos , Humanos , Laboratorios Clínicos/normas , Garantía de la Calidad de Atención de Salud/normas , Control de Calidad , Laboratorios/normas
12.
Clin Infect Dis ; 77(Suppl 7): S588-S596, 2023 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-38118017

RESUMEN

BACKGROUND: Strengthening external quality assessment (EQA) services across the One Health sector supports implementation of effective antimicrobial resistance (AMR) control strategies. Here we describe and compare 2 different approaches for conducting virtual laboratory follow-up assessments within an EQA program to evaluate quality management system (QMS) and procedures for pathogen identification and antimicrobial susceptibility testing (AST). METHODS: During the coronavirus disease 2019 (COVID-19) pandemic in 2021 and 2022, 2 laboratory assessment approaches were introduced: virtual-based and survey-based methodologies. The evaluation of 2 underperforming Animal Health laboratories through a virtual-based approach occurred between May and August 2021. This evaluation encompassed the utilization of 3 online meetings and document reviews, performed subsequent to the execution of EQA procedures. Within a distinct group of laboratories, the survey-based assessment was implemented from December 2021 to February 2022, also following EQA procedures. This phase encompassed the dissemination of an online survey to 31 participating laboratories, alongside a sole online consultation meeting involving 4 specific underperforming laboratories. RESULTS: The virtual-based assessment post-EQA aimed to identify gaps and areas for improvement in the laboratory's practices for pathogen identification and AST. This approach was, however, time-intensive, and, hence, only 2 laboratories were assessed. In addition, limited interactions in virtual platforms compromised the assessment quality. The survey-based post-EQA assessment enabled evaluation of 31 laboratories. Despite limitations for in-depth analysis of each procedure, gaps in QMS across multiple laboratories were identified and tailored laboratory-specific recommendations were provided. CONCLUSIONS: Reliable internet and plans for efficient time management, post-EQA virtual laboratory follow-up assessments are an effective alternative when conducting onsite evaluation is infeasible as observed during the COVID-19 pandemic, although the successful implementation of remediation plans will likely require in person assessments. We advocate application of hybrid approaches (both onsite and virtual) for targeted capacity building of AMR procedures with the ability to implement and oversee the process.


Asunto(s)
Antiinfecciosos , COVID-19 , Salud Única , Humanos , Control de Calidad , Laboratorios , Pandemias/prevención & control , Asia , Garantía de la Calidad de Atención de Salud , Prueba de COVID-19
13.
Crit Rev Clin Lab Sci ; : 1-14, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37779370

RESUMEN

Point-of-care testing (POCT) is the fastest-growing segment of laboratory medicine. This review focuses on the essential aspects of setting analytical performance specifications (APS) and performing quality assurance for POCT in primary healthcare. In-vitro diagnostic medical devices for POCT are typically small and easy to operate. Users often have little to no laboratory experience and may not necessarily see the value of conducting quality assurance on their devices. Therefore, training, guidance, and motivation should be integral parts of the total quality management system, as they are vital for managing errors and ensuring reliable results. It is common to believe that the analytical quality of POCT should be comparable to that of laboratory testing, and as a result, APS should be the same. This paper challenges this concept. The APS for POCT can often be less stringent compared to those used in a central laboratory because the requester is closer to both the analytical and clinical situation. Point-of-care instruments should be selected based on clinical needs, the required analytical quality and user-friendliness in the intended usage setting.Quality assurance should include both internal quality control (IQC) and external quality assessment (EQA). It is recommended that IQC protocols should be dependent on the complexity of the POCT device. A scoring system to determine how frequent IQC should be analyzed in primary healthcare on different types of POCT devices has been suggested. The main challenge in EQA for POCT involves using suitable control materials that reflect instrument performance on patient samples. Obtaining commutable control materials for POCT is difficult since the matrix often is whole blood. An essential aspect of EQA for POCT is that feedback reports should be easily interpretable. Users should receive advice from the EQA organizer regarding the root causes of deviating results. Quality assurance for POCT is not an easy task and presents numerous challenges. However, there is evidence that quality assurance improves the quality of POCT measurements and, consequently, can enhance patient outcomes.

14.
BMC Infect Dis ; 23(1): 315, 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37165323

RESUMEN

BACKGROUND: As the Human Immunodeficiency Virus (HIV) rapid testing services expanded to reach the global target that 95% of people living with the virus will know their status by 2030, ensuring the quality of those services becomes critical. This study was conducted to assess the performance of HIV Rapid testing at sites in health facilities that were enrolled in the Rapid Test Quality Improvement Initiative (RTQII) in Ethiopia. METHODS: Characterized HIV proficiency testing (PT) panels of Dried Tube Specimen (DTS) were prepared, verified, and distributed to testing sites from August to December 2019. In addition on-site evaluation of HIV testing sites (HTSs) was conducted using a checklist to assess testing conditions. For proficiency testing, the study included 159 HIV testing sites (HTSs) in 41 Health facilities (HFs) in five administrative regions and two city administrations. The collected data was analyzed by SPSS version 20 and chi-square test was applied to identify the association between acceptable performance and contributing factors. Testing sites with 100% PT score as well as conducting the test with adherence to the National HIV Testing Algorithm were considered acceptable. RESULTS: The overall acceptable performance (100% PT score with the correct algorithm followed) was found to be 62% while 12% scored 80% and 11% scored between 20 and 60%. The rest 15% were not considered as acceptable due to failure to adhere to the National HIV Testing Algorithm. Testing sites that participated in External Quality Assessment/Proficiency Testing schemes have shown better performance than those that did not participate with 70% and 56% performance respectively (p = 0.057).


Asunto(s)
Infecciones por VIH , Humanos , Infecciones por VIH/diagnóstico , Etiopía , Mejoramiento de la Calidad , Prueba de VIH , Instituciones de Salud
15.
Clin Chem Lab Med ; 61(9): 1597-1604, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37141618

RESUMEN

OBJECTIVES: To find suitable external quality assessment (EQA) materials for serum C-peptide, we evaluated the commutability of five types of processed materials. METHODS: Seventy-four individual serum samples and 12 processed samples including three EQA samples currently in use, frozen human serum pools (FHSP), and three other kinds of processed samples were prepared by dissolving WHO International Standard Reagent for C-peptide (WHO ISR 13/146) in three different matrixes: 0.05 % bovine serum albumin, fetal bovine serum and human serum pools. Samples were analyzed using the isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method and six widely used immunoassays. The commutabilities of processed materials were assessed according to the difference in bias approach recommended by the IFCC. And the short- and long-term stability of FHSP samples at different temperatures were also evaluated. RESULTS: Out of the five kinds of processed materials, FHSP samples were commutable on most assays. In contrast, the EQA materials currently in use were only commutable on a few immunoassays. Additionally, processed materials derived from WHO ISR 13/146 were found to be un-commutable on over half of immunoassays. The FHSP samples could be stably stored at 4 and -20 °C for at least 16 days, and at -80 °C for at least 1 year, but at room temperature only for 12 h. CONCLUSIONS: With clarified commutability and stability information, the human serum pool samples along with the developed ID-LC-MS/MS method could be used in the EQA program to promote the comparability among laboratories for C-peptide measurement in China.


Asunto(s)
Laboratorios , Espectrometría de Masas en Tándem , Humanos , Péptido C , Cromatografía Liquida , Sesgo , Estándares de Referencia
16.
Clin Chem Lab Med ; 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38008748

RESUMEN

OBJECTIVES: This paper evaluates 16 year results of the Allergy EQA program shared by EQA organisers in Belgium, Finland, Portugal, and The Netherlands. METHODS: The performance of Thermo Fisher and Siemens user groups (in terms of concordance between both groups, between laboratory CV, prevalence of clinically significant errors) and suitability of samples (stability and validity of dilution of patient samples) are evaluated using data of 192 samples in the EQA programs from 2007 to 2022. Measurands covered are total IgE, screens and mixes, specific IgE extracts and allergen components. RESULTS: There is perfect (53 %), acceptable (40 %) and poor (6 %) concordance between both method groups. In case of poor concordance the best fit with clinical data is seen for Thermo Fisher (56 %) and Siemens (26 %) respectively. The between laboratory CV evolves from 7.8 to 6.6 % (Thermo Fisher) and 7.3 to 7.7 % (Siemens). The prevalence of blunders by individual laboratories is stable for Siemens (0.4 %) and drops from 0.4 to 0.2 % for Thermo Fisher users. For IgE, the between year CV of the mean of both user groups is 1 %, and a fifteen-fold dilution of a patient sample has an impact of 2 and 4 % on the recovery of Thermo Fisher and Siemens user groups. CONCLUSIONS: The analytical performance of Thermo Fisher is slightly better than that of Siemens users but the clinical impact of this difference is limited. Stability of the sample and the low impact of dilution on the recovery of measurands demonstrates the suitability for purpose of the EQA program.

17.
Clin Chem Lab Med ; 61(9): 1643-1651, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-36988017

RESUMEN

OBJECTIVES: NT-proBNP is frequently used for ruling out heart failure. Different cut-offs are used depending on the clinical context, e.g. an acute or chronic condition. Medical decision limits have been suggested at 125 and 300 ng/L or 400 ng/L in international guidelines. However, there is limited standardization between NT-proBNP methods and using the same blood sample might cause different treatment of patients. METHODS: Data from the external quality assessment program for NT-proBNP from Equalis, Sweden, were extracted for the period 2011-2021, and categorized according to manufacturer. Manufacturer median NT-proBNP values were compared to total median values. CV% was calculated for each manufacturer and in comparison to different levels of NT-proBNP. RESULTS: Roche was the most common method, and its median results were closest to the median consensus results. When looking at the total CV at NT-proBNP levels in the range of 0-500 ng/L, the total CV varied from 4 to 27%. During 2019-2021, Siemens (Immulite, Centaur, Atellica) yielded results 16-20% above the consensus median depending on sample level. Similarly, Abbott was 5-7% above, while Roche and Siemens Stratus were 1% respectively 6-10% below the consensus median. CONCLUSIONS: The introduction of new manufacturers and methods in 2017 have caused the agreement between manufacturers to decline. This highlights the need for a common calibrator and reference materials, particularly since medical decision limits in guidelines, e.g. European Society of Cardiology 2021, which are mostly based on Roche methods, do not take these method differences into account.


Asunto(s)
Insuficiencia Cardíaca , Laboratorios , Humanos , Suecia , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Biomarcadores
18.
Clin Chem Lab Med ; 61(8): 1455-1462, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36866730

RESUMEN

OBJECTIVES: Except for the large bias of some measurement systems for serum cystatin C (CysC) measurements, unacceptable imprecision has been observed for the heterogenous system. This study analyzed the external quality assessment (EQA) results in 2018-2021 to provide an insight into the imprecision of CysC assays. METHODS: Five EQA samples were sent to participating laboratories every year. Participants were divided into reagent/calibrator-based peer groups, for which the robust mean of each sample and robust coefficient of variation (CV) were calculated by Algorithm A from ISO 13528. Peers with more than 12 participants per year were selected for further analysis. The limit of CV was determined to be 4.85% based on clinical application requirements. The concentration-related effect on CVs was investigated using logarithmic curve fitting; the difference in medians and robust CVs between instrument-based subgroups was also evaluated. RESULTS: The total number of participating laboratories increased from 845 to 1,695 in four years and heterogeneous systems remained the mainstream (≥85%). Of 18 peers with ≥12 participants, those using homogeneous systems showed relatively steady and small CVs over four years, with the mean four-year CVs ranging from 3.21 to 3.68%. Some peers using heterogenous systems showed reduced CVs over four years, while 7/15 still had unacceptable CVs in 2021 (5.01-8.34%). Six peers showed larger CVs at the low or high concentrations, and some instrument-based subgroups presented greater imprecision than others. CONCLUSIONS: More efforts should be made to improve the imprecision of heterogeneous systems for CysC measurement.


Asunto(s)
Cistatina C , Humanos , Pruebas de Función Renal
19.
Clin Chem Lab Med ; 61(12): 2237-2247, 2023 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-37377068

RESUMEN

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection is an indispensable tool for epidemic surveillance in the post-pandemic era. Faced with irregular performance, a comprehensive external quality assessment (EQA) scheme was conducted by the National Center for Clinical Laboratories (NCCL) to evaluate the analytical performance and status of SARS-CoV-2 antigen tests. METHODS: The EQA panel included ten lyophilized samples containing serial 5-fold dilutions of inactivated SARS-CoV-2-positive supernatants of the Omicron BA.1 and BA.5 strains and negative samples, which were classified into "validating" samples and "educational" samples. Data were analyzed according to qualitative results for each sample. RESULTS: A total of 339 laboratories in China participated in this EQA scheme, and 378 effective results were collected. All validating samples were correctly reported by 90.56 % (307/339) of the participants and 90.21 % (341/378) of the datasets. The positive percent agreement (PPA) was >99 % for samples with concentrations of 2 × 107 copies/mL but was 92.20 % (697/756) for 4 × 106 copies/mL and 25.26 % (382/1,512) for 8 × 105 copies/mL samples. Colloidal gold was the most frequently used (84.66 %, 320/378) but showed the lowest PPAs (57.11 %, 1,462/2,560) for positive samples compared with fluorescence immunochromatography (90 %, 36/40) and latex chromatography (79.01 %, 335/424). Among 11 assays used in more than 10 clinical laboratories, ACON showed a higher sensitivity than other assays. CONCLUSIONS: The EQA study can help to validate whether it's necessary to update antigen detection assays for manufacturers and provide participants with information about the performance of assays to take the first step toward routine post-market surveillance.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Laboratorios , Pandemias , Prueba de COVID-19 , Sensibilidad y Especificidad
20.
Clin Chem Lab Med ; 61(8): 1404-1410, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36779362

RESUMEN

OBJECTIVES: Clinical laboratory results are required for critical medical decisions, underscoring the importance of quality results. As part of total quality management, external quality assessment (EQA) is a vital component to ensure laboratory accuracy. The goal of this survey was to evaluate the current status of global laboratory quality systems and assess the need for implementation, expansion, or harmonization of EQA programs (EQAP) for Clinical Chemistry and Laboratory Medicine. METHODS: The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a survey of IFCC full and affiliate members (n=110) on laboratory quality practice. A total of 41 (37.3%) countries representing all IFCC regions except North America provided responses about EQA availability and practices. RESULTS: All 41 countries perform EQA, 38 reported that their laboratories had EQA policies and procedures, and 39 further act/evaluate unacceptable EQA results. 39 countries indicated they have international and/or national EQAP and 30 use alternative performance assessments. EQA frequency varied among countries. Generally, an EQAP provided the EQA materials (40/41) with four countries indicating that they did not have an EQAP in their country. CONCLUSIONS: Globally, most laboratories participate in an EQAP and have defined quality procedures for EQA. There remain gaps in EQA material availability and implementation of EQA as a part of a total laboratory quality system. This survey highlights the need for education, training, and harmonization and will guide efforts of the IFCC TF-GLQ in identifying areas for enhancing global laboratory quality practices.


Asunto(s)
Química Clínica , Laboratorios , Humanos , Encuestas y Cuestionarios , Gestión de la Calidad Total , Garantía de la Calidad de Atención de Salud