Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Thromb Thrombolysis ; 55(3): 474-489, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36528721

RESUMEN

Since the beginning of the SARS-CoV-2 (COVID-19) pandemic, correlation of venous thromboembolism (VTE) and COVID-19 infection has been well established. Increased inflammatory response in the setting of COVID-19 infection is associated with VTE and hypercoagulability. Venous and arterial thrombotic events in COVID-19 infection have been well documented; however, few cases have been reported involving cardiac valve prostheses. In this review, we present a total of eight cases involving COVID-19-related prosthetic valve thrombosis (PVT), as identified in a systematic review. These eight cases describe valve position (mitral versus aortic) and prosthesis type (bioprosthetic versus mechanical), and all cases demonstrate incidents of PVT associated with simultaneous or recent COVID-19 infection. None of these eight cases display obvious non-adherence to anticoagulation; five of the cases occurred greater than three years after the most recent valve replacement. Our review offers insights into PVT in COVID-19 infected patients including an indication for increased monitoring in the peri-infectious period. We explore valve thrombosis as a mechanism for prosthetic valve failure. We describe potential differences in antithrombotic strategies that may offer added antithrombotic protection during COVID-19 infection. With the growing population of valve replacement patients and recurring COVID-19 infection surges, it is imperative to explore relationships between COVID-19 and PVT.


Asunto(s)
COVID-19 , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Tromboembolia Venosa , Humanos , Fibrinolíticos , Tromboembolia Venosa/complicaciones , COVID-19/complicaciones , SARS-CoV-2 , Enfermedades de las Válvulas Cardíacas/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Trombosis/complicaciones , Válvula Aórtica
2.
Gac Med Mex ; 159(3): 210-218, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37494706

RESUMEN

BACKGROUND: Heart valve replacement surgery with mechanical or biological prostheses entails a risk of thromboembolism and bleeding complications. OBJECTIVE: To determine the complications related to complementary anticoagulation therapy and the probability of risk. METHODS: One-hundred and sixty-three patients who underwent heart valve replacement between 2002 and 2016 with either mechanical or biological prostheses, and who received vitamin K antagonists after hospital discharge, were studied. Anticoagulation therapy was categorized into optimal and non-optimal according to INR values prior to the development of complications. Patients with comorbidities and other risk factors for thrombosis and/or bleeding were excluded. RESULTS: In total, 68.7 % of patients received mechanical prostheses, and 31.3 %, biological prostheses (p ≤ 0.001); 25.2 % experienced the complications that motivated the study (p ≤ 0.001), which were hemorrhagic in 48.8 %, thromboembolic in 26.8 %, and of both types in 24.4 % (relative risk = 4.229). Among the patients with complications, 95.1 % received mechanical prostheses, and 4.9 %, biological (p = 0.005); non-optimal INR was identified in 49.7 % (p ≤ 0.001). CONCLUSIONS: Given the high risk of thromboembolic and hemorrhagic complications, valve prostheses must be carefully chosen, and care priorities should include prevention and follow-up, especially in those patients who require anticoagulation therapy.


ANTECEDENTES: El reemplazo valvular por prótesis mecánicas o biológicas implica riesgo de tromboembolismo y complicaciones hemorrágicas. OBJETIVO: Determinar las complicaciones relacionadas con la terapia de anticoagulación complementaria y la probabilidad de riesgo en pacientes portadores de prótesis valvulares del corazón. MÉTODOS: Se estudiaron 163 pacientes entre 2002 y 2016, portadores de prótesis mecánicas y biológicas, quienes recibieron antagonistas de la vitamina K posterior al egreso hospitalario. La terapia de anticoagulación se categorizó en óptima y no óptima conforme a los valores de INR previos a las complicaciones. Fueron excluidos los pacientes con comorbilidades y otros factores de riesgo de trombosis y/o sangrado. RESULTADOS: a 68.7 % de los pacientes se les colocó prótesis mecánica y a 31.3 %, biológica (p ≤ 0.001); 25.2 % presentó las complicaciones motivo de estudio (p ≤ 0.001), hemorrágicas en 48.8 %, tromboembólicas en 26.8 % y de ambos tipos en 24.4 % (riesgo relativo = 4.229); a 95.1 % de los pacientes con complicaciones se les colocó prótesis mecánica y a 4.9 %, biológica (p = 0.005); 49.7 % presentó INR no óptimo (p ≤ 0.001). CONCLUSIONES: Ante riesgo alto de complicaciones tromboembólicas y hemorrágicas, la elección de las prótesis valvulares, la prevención y el seguimiento son prioridades, principalmente en quienes requieren terapia de anticoagulación.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Tromboembolia , Humanos , Centros de Atención Terciaria , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control , Prótesis Valvulares Cardíacas/efectos adversos , Anticoagulantes/uso terapéutico , Hemorragia/epidemiología , Hemorragia/etiología , Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
3.
Rev Cardiovasc Med ; 23(10): 343, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39077122

RESUMEN

Prosthetic valves are increasingly encountered in clinical practice. A grasp of the intricacies of the assessment and management of prosthetic valves is thus a crucial skillset for the practicing cardiologist. Echocardiography is the imaging modality of choice for the anatomic and functional evaluation of prosthetic valve. This document reviews the general features of prosthetic valves, echocardiographic identification of normally functioning and dysfunctional prosthetic valves as well as echocardiographic diagnosis of specific prosthetic valvular abnormalities.

4.
J Card Surg ; 37(9): 2776-2785, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35701901

RESUMEN

BACKGROUND: Prosthetic valve thrombosis (PVT) is a rare but life-threatening complication. Surgery and fibrinolytic therapy (FT) are the two main treatment options for PVT. The choice between surgery and FT has always been a matter of debate. Previous studies have shown that although the mortality rate is higher in surgery, complications are less frequent than in FT. We aimed to perform a systematic review and meta-analysis to compare the results of surgery and FT in PVT. METHODS: A systematic review of the literature was performed through Medline, Embase, Scopus, and Web of Science, encompassing all studies comparing surgery and FT in PVT. The rate of each complication and risk ratio (RR) of complications in surgery and FT were assessed using random-effects models. RESULTS: Fifteen studies with 1235 patients were included in the meta-analysis. The pooled risk of the mortality was not significantly different between FT and surgery in patients with PVT (pooled RR = 0.78, 95% confidence interval [CI]: 0.38-1.60, I² = 61.4%). The pooled risks of thromboembolic events (pooled RR = 4.70, 95% CI: 1.83-12.07, I² = 49.6%) and major bleeding (pooled RR = 2.45, 95% CI: 1.09-5.50, I² = 41.1%) and PVT recurrence (pooled RR = 2.06 95% CI: 1.29-3.27, I² = 0.0%) were significantly higher in patients who received FT. CONCLUSION: Surgery may be safer and with fewer complications than FT for PVT treatment. However, randomized clinical trials are needed to determine the proper treatment for PVT.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Fibrinolíticos/uso terapéutico , Enfermedades de las Válvulas Cardíacas/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Terapia Trombolítica/métodos , Trombosis/tratamiento farmacológico , Trombosis/etiología
5.
J Card Surg ; 37(4): 855-864, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35072279

RESUMEN

BACKGROUND: The incidence of prosthetic tricuspid valve (TV) thrombosis is the highest among heart valves. It can lead to high morbidity and mortality without proper treatment. In this study, we sought to report the management and clinical outcomes of patients with mechanical TV thrombosis. METHODS: The current study was conducted in Rajaei Heart Center on 42 patients with mechanical TV thrombosis from 2006 to 2017. The baseline characteristics and the rates of adverse events during the follow-up period were assessed. RESULTS: A total of 67 episodes of mechanical TV thrombosis in 42 patients were observed. The mean age of patients was 45.5 ± 14.3 years (19-77), and overall two-thirds were female. Thrombolytic therapy was used in 41 (61.1%), anticoagulant intensification in 16 (23.9%), and surgery as the first approach in 10 (14.9%) episodes; subsequently, surgery as the final approach was implemented in 20 (29.8%) episodes. In-hospital mortality occurred in two (2.98%) patients. The rates of freedom from recurrent thrombosis were 84%, 61%, and 21% at the end of 1, 4, and 10 years, respectively. Survival rates and freedom from chronic valve dysfunction were 93%, 82%, and 75% after 1, 4, and 10 years. CONCLUSIONS: The results of the present study showed that recurrent thrombosis requiring intervention is a major complication of mechanical TV, which underscores individual-approached therapy and close follow-up.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Adulto , Anciano , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Terapia Trombolítica/efectos adversos , Trombosis/tratamiento farmacológico , Trombosis/etiología , Trombosis/cirugía , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Adulto Joven
6.
J Card Surg ; 37(4): 865-867, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34996127

RESUMEN

With limited data available for the tricuspid valve, there are no stringent recommendations in the current guidelines (ESC 2021). Valve replacement for the right-sided heart is inherently problematic and bears the potential for complications - including prosthetic valve thrombosis (PVT). The purpose of this editorial is to review the key features of this clinical scenario and to outline the essential aspects for optimized patient management and improved outcome. Depending on the clinical presentation of PVT, either immediate surgery, thrombolysis, or anticoagulation may be considered - with the sole intensification of anticoagulation likely being the most inferior. Given the high risk of re-thrombosis, a dedicated follow-up program is essential to identify complications early and offer adequate treatment.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Enfermedades de las Válvulas Cardíacas/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Terapia Trombolítica/efectos adversos , Trombosis/tratamiento farmacológico , Válvula Tricúspide/cirugía
7.
Int J Mol Sci ; 23(12)2022 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-35743174

RESUMEN

A 72-year-old female patient with mixed rheumatic mitral valve disease and persistent atrial fibrillation underwent mitral valve replacement and suffered from a combined thrombosis of the bioprosthetic valve and the left atrium as soon as 2 days post operation. The patient immediately underwent repeated valve replacement and left atrial thrombectomy. Yet, four days later the patient died due to the recurrent prosthetic valve and left atrial thrombosis which both resulted in an extremely low cardiac output. In this patient's case, the thrombosis was notable for the resistance to anticoagulant therapy as well as for aggressive neutrophil infiltration and release of neutrophil extracellular traps (NETs) within the clot, as demonstrated by immunostaining. The reasons behind these phenomena remained unclear, as no signs of sepsis or contamination of the BHV were documented, although the patient was diagnosed with inherited thrombophilia that could impede the fibrinolysis. The described case highlights the hazard of immunothrombosis upon valve replacement and elucidates its mechanisms in this surgical setting.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Anciano , Femenino , Atrios Cardíacos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Tromboinflamación , Trombosis/diagnóstico
8.
Am J Emerg Med ; 49: 439.e1-439.e2, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33972122

RESUMEN

Prosthetic valve thrombosis (PVT) is considered an exceptionally rare condition, often associated with pro-thrombotic factors or suboptimal anticoagulant therapy. Guidelines recommend emergent surgery for patients with left heart valve prosthetic thrombosis who present in cardiogenic shock, and systemic thrombolysis is reserved in scenarios where surgery is not immediately available. However, several factors may affect surgical prognosis and are overlooked by current recommendations. We describe the case of a 34-year-old female who presented in the emergency department with cardiogenic shock and acute pulmonary edema due to acute valve thrombosis.


Asunto(s)
Válvulas Cardíacas/anomalías , Terapia Trombolítica/métodos , Trombosis/tratamiento farmacológico , Adulto , Femenino , Fibrinolíticos/uso terapéutico , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvulas Cardíacas/diagnóstico por imagen , Humanos , Trombosis/fisiopatología
9.
Pak J Med Sci ; 37(2): 325-330, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33679907

RESUMEN

OBJECTIVE: To evaluate the outcome of thrombolysis in patients of prosthetic valve thrombosis. METHODS: This retrospective analysis was conducted on data of 84 patients of prosthetic valve thrombosis who presented to emergency room of Faisalabad Institute of Cardiology between July 2017 to December 2019. The diagnosis of prosthetic valve thrombosis was based on clinical suspicion and bed side transthoracic echocardiography done by a consultant cardiologist. Fluoroscopy was done to confirm the diagnosis by observing immobile valve leaflet. The confirmed patients were then treated in emergency with streptokinase after taking an informed consent. Quantitative variables like age were summarized by mean and standard deviation. Qualitative variables like gender, successful thrombolysis, stroke, major bleeding, mortality or re-do surgery were summarized by frequency and percentage. RESULTS: Mean age was 29 ± 6.36, years and there were more female patients (n=43, 51.25%) as compared to males (n=41, 48.8%). Among the 66 surviving patients thrombolysis was successful without any complications in 56 patients (66.7%). Thrombolysis was successful with minor complications in six patients (7.1%) and it failed to produce desired results in four patients (4.8%). In this study 18 (21.4%) patients died. The common complications included minor bleeding in four patients (4.8%) and major bleeding in 10 patients (12.0 %). CONCLUSION: Thrombolysis produces reasonable success rate in cases of prosthetic valve thrombosis who are in functional class I or II. However, it has very high mortality rate in patients presenting with functional class III and IV.

10.
Cardiol Young ; 30(11): 1747-1749, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32880248

RESUMEN

Prosthetic valve thrombosis is a serious complication of prosthetic heart valves that typically requires either surgical intervention or systemic thrombolysis. In patients with contraindications to both treatment modalities, options can be limited. We describe an alternative approach to managing prosthetic valve thrombosis in an infant presenting in extremis with pulmonary haemorrhage. Using transoesophageal echocardiography and fluoroscopic guidance, we restored function to the infant's obstructed St. Jude prosthetic mitral valve through percutaneous transcatheter manipulation of the valve's leaflets.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Lactante , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Trombosis/etiología
11.
Heart Lung Circ ; 29(3): 469-474, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31409533

RESUMEN

BACKGROUND: Prosthetic valve thrombosis (PVT) is an uncommon but serious cause of morbidity and mortality after cardiac valve implantation. The most common cause leading to PVT is inadequate anticoagulation. Royal Darwin Hospital is a major referral centre for the Top End of Australia and is unique in having a high burden of rheumatic heart disease (RHD) requiring valve surgery, issues with adherence with oral anticoagulants, and the absence of onsite cardiothoracic facility. METHODS: We report clinical characteristics and outcomes of consecutive patients presenting with PVT to a single centre without on-site cardiothoracic surgery. RESULTS: Thirty-two (32) episodes involving 21 patients were retrospectively identified between 2000 and 2017. Our cohort had an average age of 37 years. Nineteen (19) patients were of Aboriginal or Torres Strait Islander descent. All valves were mechanical, except for one bioprosthetic mitral valve, with average time from implantation to initial PVT 5.1 years. The majority of patients were in New York Heart Association (NYHA) class III and IV (6%, and 66%, respectively). Anti-coagulation was sub-therapeutic in 88% of presentations. Eleven (11) (34%) presentations were recurrent PVT involving eight patients. Twenty-six (26) (82%) episodes were treated with thrombolytic therapy which achieved complete success in 65% and partial success in 19%. Five (5) patients received a second dose of the lytic agent. Of the four patients not responding to thrombolytic therapy, two died and two were urgently transferred to a facility with on-site cardiothoracic surgery. Five (5) out of 32 episodes resulted in death (16%) with overall mortality 24% for the cohort over the entire time period. Thrombolytic therapy was associated with five major bleeding episodes (16%) including two fatal bleeds. CONCLUSIONS: Prosthetic valve thrombosis is a rare but life-threatening complication of prosthetic valves, with the vast majority of patients found to be inadequately anticoagulated. Despite differences in thrombolytic agents these were successful in the majority of patients.


Asunto(s)
Anticoagulantes/administración & dosificación , Prótesis Valvulares Cardíacas/efectos adversos , Cardiopatía Reumática , Terapia Trombolítica , Trombosis , Administración Oral , Adulto , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Northern Territory , Estudios Retrospectivos , Cardiopatía Reumática/mortalidad , Cardiopatía Reumática/terapia , Tasa de Supervivencia , Trombosis/etiología , Trombosis/mortalidad , Trombosis/terapia
12.
J Biomech Eng ; 141(10)2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31053843

RESUMEN

Prosthetic valve thrombosis (PVT) is a serious complication affecting prosthetic heart valves. The transvalvular mean pressure gradient (MPG) derived by Doppler echocardiography is a crucial index to diagnose PVT but may result in false negatives mainly in case of bileaflet mechanical valves (BMVs) in mitral position. This may happen because MPG estimation relies on simplifying assumptions on the transvalvular fluid dynamics or because Doppler examination is manual and operator dependent. A deeper understanding of these issues may allow for improving PVT diagnosis and management. To this aim, we used in vitro and fluid-structure interaction (FSI) modeling to simulate the function of a real mitral BMV in different configurations: normally functioning and stenotic with symmetric and completely asymmetric leaflet opening, respectively. In each condition, the MPG was measured in vitro, computed directly from FSI simulations and derived from the corresponding velocity field through a Doppler-like postprocessing approach. Following verification versus in vitro data, MPG computational data were analyzed to test their dependency on the severity of fluid-dynamic derangements and on the measurement site. Computed MPG clearly discriminated between normally functioning and stenotic configurations. They did not depend markedly on the site of measurement, yet differences below 3 mmHg were found between MPG values at the central and lateral orifices of the BMV. This evidence suggests a mild uncertainty of the Doppler-based evaluation of the MPG due to probe positioning, which yet may lead to false negatives when analyzing subjects with almost normal MPG.

13.
J Thromb Thrombolysis ; 45(4): 571-577, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29524112

RESUMEN

Prosthetic valve thrombosis (PVT) is a potentially life-threatening complication associated with high morbidity and mortality. The CHA2DS2-VASc is a clinical score used to determine thromboembolism risk in non-valvular atrial fibrillation patients. Therefore; in this study, we aimed to determine predictive value of the CHA2DS2-VASc score for development of PVT in patients with mechanical prosthetic valve. This was a retrospective study included 417 consecutive patients with mechanic prosthetic valve in whom transesophageal echocardiography (TEE) was performed due to different clinical indications from January 2004 to June 2016. After evaluation according to exclusion criteria, 267 patients with mechanic prosthetic valve were enrolled in the study. The definitive diagnosis of the PVT was made as proposed by TEE finding. The study population was divided into two groups; PVT patients (154 patients) and control group (113 patients) with functional prosthetic valve. The CHA2DS2-VASc score was calculated for each patient from the hospital electronic database. The mechanical mitral valve thrombosis predictive value of variables including CHA2DS2-VASc score was tested in our study. The mean CHA2DS2-VASc score was significantly higher in PVT patients compared to control patients (2.51 ± 1.54 vs. 1.13 ± 1.21, p < 0.01). Both on univariate and multivariate analysis demonstrated that the CHA2DS2-VASc score is independently associated with PVT (p < 0.001 and p < 0.001, respectively). The patients whose CHA2DS2-VASc score ≥ 1-3 had 6.20 times higher risk for thrombus formation, and patients whose CHA2DS2-VASc score ≥ 4 had 16.6 times higher risk for thrombus formation compared to patients with CHA2DS2-VASc score = 0 (p < 0.001 and p < 0.001, respectively). The CHA2DS2-VASc score may be a significant independent predictor of PVT in patients with prosthetic valve and the CHA2DS2-VASc score ≥ 2.5 or more was associated with increased PVT in patients with prosthetic valve. Thus; it may be an applicable risk scoring system to assess the risk of development of PVT in patients with prosthetic valve.


Asunto(s)
Prótesis Valvulares Cardíacas/efectos adversos , Medición de Riesgo/métodos , Trombosis/etiología , Anciano , Estudios de Casos y Controles , Humanos , Persona de Mediana Edad , Válvula Mitral , Análisis Multivariante , Estudios Retrospectivos
14.
Echocardiography ; 35(3): 388-390, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29457259

RESUMEN

Intermittent dysfunction of mechanical mitral valve prosthesis is an uncommon condition. It carries serious clinical implications if unrecognized. Here, we present a case of a 28-year-old female with a history of rheumatic multivalvular disease, for which she had undergone double valve replacement and tricuspid annuloplasty. Six months later, she presented with heart failure. Clinical examination revealed intermittent loss of closing clicks followed by a pansystolic murmur at the apex, suggestive of mitral prosthetic valve dysfunction. We highlight the echocardiographic findings of paroxysmal mitral valvular regurgitation secondary to prosthetic valve malfunction secondary to prosthetic valve thrombosis.


Asunto(s)
Trombosis Coronaria/complicaciones , Trombosis Coronaria/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Falla de Prótesis/efectos adversos , Adulto , Trombosis Coronaria/cirugía , Ecocardiografía/métodos , Femenino , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Reoperación
15.
J Stroke Cerebrovasc Dis ; 26(5): 1110-1113, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28094188

RESUMEN

BACKGROUND: Stroke may be the first symptom of prosthetic valve thrombosis (PVT); therefore, rapid diagnosis and therapy are crucial. We aimed to evaluate the prevalence, main predictors, and long-term clinical evolution of patients with PVT in the acute phase of stroke. METHODS: We studied consecutive acute ischemic stroke patients with prosthetic heart valves who underwent emergent transesophageal echocardiography (TEE) during a 5-year period. Two groups were defined depending on the presence of PVT (PVT or non-PVT groups). Baseline characteristics, TEE findings, and international normalized ratios (INRs) at the stroke event were registered. Follow-up visits and TEE control examinations were performed. RESULTS: Sixty-seven patients were registered. TEE was performed within the first week in 85% of patients (n = 57). PVT was diagnosed in 41.8% of cases (n = 28). Clinical severity and baseline INR level showed no differences when the PVT and non-PVT groups were compared. The presence of PVT was associated with the mitral valve location as compared with the aortic valve location (75% versus 25%, P = .003), the presence of spontaneous echocontrast (64.3% versus 35.9%, P = .022), and low ejection fraction (66.7% versus 32.7%, P = .019). The PVT group showed a trend toward higher percentage of recurrence (10.7% versus 2.5%, P = .102) in the follow up period (mean follow-up 25 months). CONCLUSIONS: The detection of PVT in the acute stroke phase was relevant, as the stroke recurrence rate was considerable. Therefore, all patients with prosthetic heart valve should undergo emergent TEE.


Asunto(s)
Válvula Aórtica/cirugía , Isquemia Encefálica/epidemiología , Enfermedades de las Válvulas Cardíacas/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Accidente Cerebrovascular/epidemiología , Trombosis/epidemiología , Anciano , Válvula Aórtica/diagnóstico por imagen , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/terapia , Bases de Datos Factuales , Ecocardiografía Transesofágica , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/terapia , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Prevalencia , Pronóstico , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , España/epidemiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/terapia , Trombosis/diagnóstico por imagen , Trombosis/terapia , Factores de Tiempo
16.
Echocardiography ; 32(1): 156-64, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25109700

RESUMEN

Prosthetic valve thrombosis (PVT) is a potentially life-threatening complication of heart valve replacement. Early diagnosis is crucial for the prevention of significantly morbid and lethal complications. Cinefluoroscopy (CF) and echocardiography have been widely used for diagnosing PVT. In recent years, the role of CF has declined since the introduction of transesophageal echocardiography and the great improvements in ultrasound technology including real time three-dimensional imaging. Nevertheless, both echocardiography and CF provide different kinds of information on prosthesis function, and therefore they are considered as complementary and not alternative. In this review, we aimed to summarize the current status of CF and echocardiography in the diagnosis of PVT.


Asunto(s)
Cinerradiografía/métodos , Ecocardiografía/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico , Prótesis Valvulares Cardíacas/efectos adversos , Trombosis/diagnóstico , Trombosis/etiología , Enfermedades de las Válvulas Cardíacas/etiología , Humanos , Falla de Prótesis
17.
J Pak Med Assoc ; 65(7): 802-3, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26160099

RESUMEN

Prosthetic valve thrombosis within one year after mitral valve replacement is rarely seen in patients on warfarin therapy and without any risk factor. Here, we describe a case of a 39-year- old female, who presented with dyspnoea and shortness of breath 11 months after mitral valve replacement. The echocardiogram revealed severe valvular stenosis due to presence of clots on the mitral valve and restricted motion of the mitral leaflets. As a result of deterioration of general condition and haemodynamic un-stability, plan was made to re-operate for her valve replacement surgery. This case report highlights the diagnosis, prevention and management of patients with prosthetic valve thrombosis following mitral valve replacement.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral , Trombosis/cirugía , Adulto , Anticoagulantes/uso terapéutico , Femenino , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Reoperación , Cardiopatía Reumática/cirugía , Trombosis/diagnóstico , Trombosis/prevención & control , Warfarina/uso terapéutico
18.
J Am Heart Assoc ; 13(19): e035143, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39291476

RESUMEN

BACKGROUND: The optimal strategy in prosthetic heart valve thrombosis (PVT) remains controversial, with no randomized trials and conflicting observational data. We performed a systematic review and meta-analysis of evidence comparing systemic thrombolysis and cardiac surgery in PVT. METHODS AND RESULTS: We searched PubMed, the Cochrane Library, and Embase for studies on treatment strategies in patients with left-sided PVT since 2000. The primary outcome was death, and the secondary outcomes were major bleeding and thromboembolism during follow-up (International Prospective Register of Systematic Reviews No. CRD42022384092). We identified 2298 studies, of which 16 were included, comprising 1389 patients with PVT (mean age, 50.4±9.3 years; 60.0% women). Among them, 67.2% were New York Heart Association stage III/IV at admission. Overall, 48.1% were treated with systemic thrombolysis and 51.9% with cardiac surgery. The mortality rate was 10.8% in the thrombolysis group and 15.3% in the surgery group. The pooled risk difference for death with systemic thrombolysis was 1.13 (exact CI, 0.74-1.79; ζ2=0.89; P<0.001) versus cardiac surgery. Rates of both transient ischemic attack and non-central nervous system embolism were higher in the thrombolysis group (P=0.002 and P=0.02, respectively). Treatment success, major bleeding, and stroke were similar between groups. Sensitivity analysis including studies that used low-dose or slow-infusion thrombolysis showed that the mortality rate was lower, and treatment success was higher, in patients referred to systemic thrombolysis, with similar rates of other secondary outcomes. CONCLUSIONS: There is evidence to suggest that thrombolysis might be the preferred option for the management of PVT without cardiogenic shock, pending future randomized controlled trials or larger observational studies.


Asunto(s)
Prótesis Valvulares Cardíacas , Terapia Trombolítica , Trombosis , Humanos , Terapia Trombolítica/métodos , Trombosis/etiología , Trombosis/tratamiento farmacológico , Hemodinámica/efectos de los fármacos , Fibrinolíticos/uso terapéutico , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Femenino , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos
19.
J Cardiol Cases ; 29(3): 112-115, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38481643

RESUMEN

A 68-year-old woman with history of aortic valve replacement developed severe heart failure and cardiac arrest. Transesophageal echocardiography and cardiac computed tomography showed mechanical aortic valve thrombosis. Low-dose, ultraslow infusion of tissue-plasminogen activator was performed while the patient was in a critically ill condition, resulting in the improvement of thrombus burden and structural valve deterioration. Learning objectives: Mechanical valve thrombosis can be an underlying mechanism of severe heart failure, in which systemic thrombolytic therapy in a low-dose, ultraslow, and prolonged manner may improve clinical outcomes, even in critically ill patients.

20.
Artículo en Inglés | MEDLINE | ID: mdl-39185999

RESUMEN

OBJECTIVES: In the context of postcardiotomy cardiogenic shock (PCCS) following valve replacement surgery, it may be necessary to implant a peripheral veno-arterial extracorporeal membrane oxygenation (pVA-ECMO). This procedure, however, carries a risk of prosthetic valve thrombosis. The aim of this retrospective study was to describe the incidence and outcomes of prosthetic valve thrombosis after VA-ECMO support for PCCS and to report the associated risk factors. METHODS: All consecutive adult patients who received pVA-ECMO for PCCS following a valve replacement procedure between January 2015 and October 2019 in our institution were included in this retrospective study. Outcome variables were prosthetic valve thrombosis, 30-day and hospital survival, pVA-ECMO-associated adverse events and surgery-related adverse events. RESULTS: During the 4-year study period, 549 patients received pVA-ECMO for PCCS. Among them, 152 had undergone a valve replacement procedure and 9 of these developed prosthetic valve thrombosis. The incidence of valve thrombosis at 30 days was 7.5 ± 2%. The cumulative Incidence of prosthetic valve thrombosis was significantly lower with pVA-ECMO + IABP versus VA-ECMO alone (1.4 ± 1.4% vs 13.7 ± 4.7%, p = 0.021, respectively). Intra-aortic balloon pump use associated with pVA-ECMO (versus pVA-ECMO alone) was an independent protective factor against hospital death (OR = 0.180 [0.068-0.478], p = 0.001). CONCLUSIONS: After PCCS following valve replacement surgery, peripheral femoro-femoral VA-ECMO is associated with a low risk of acute valve thrombosis especially when associated with an IABP.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA