Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.060
Filtrar
Más filtros

Intervalo de año de publicación
1.
Neuroimage ; 286: 120504, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38216104

RESUMEN

Small cerebral blood vessels are largely inaccessible to existing clinical in vivo imaging technologies. This study aims to present a novel analysis pipeline for vessel density mapping of small cerebral blood vessels from high-resolution 3D black-blood MRI at 3T. Twenty-eight subjects (10 under 35 years old, 18 over 60 years old) were imaged with the T1-weighted turbo spin-echo with variable flip angles (T1w TSE-VFA) sequence optimized for black-blood small vessel imaging with iso-0.5 mm spatial resolution (interpolated from 0.51×0.51×0.64 mm3) at 3T. Hessian-based vessel segmentation methods (Jerman, Frangi and Sato filter) were evaluated by vessel landmarks and manual annotation of lenticulostriate arteries (LSAs). Using optimized vessel segmentation, large vessel pruning and non-linear registration, a semiautomatic pipeline was proposed for quantification of small vessel density across brain regions and further for localized detection of small vessel changes across populations. Voxel-level statistics was performed to compare vessel density between two age groups. Additionally, local vessel density of aged subjects was correlated with their corresponding gross cognitive and executive function (EF) scores using Montreal Cognitive Assessment (MoCA) and EF composite scores compiled with Item Response Theory (IRT). Jerman filter showed better performance for vessel segmentation than Frangi and Sato filter which was employed in our pipeline. Small cerebral blood vessels including small artery, arterioles, small veins, and venules on the order of a few hundred microns can be delineated using the proposed analysis pipeline on 3D black-blood MRI at 3T. The mean vessel density across brain regions was significantly higher in young subjects compared to aged subjects. In the aged subjects, localized vessel density was positively correlated with MoCA and IRT EF scores. The proposed pipeline is able to segment, quantify, and detect localized differences in vessel density of small cerebral blood vessels based on 3D high-resolution black-blood MRI. This framework may serve as a tool for localized detection of small vessel density changes in normal aging and cerebral small vessel disease.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Humanos , Anciano , Adulto , Persona de Mediana Edad , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Angiografía por Resonancia Magnética/métodos , Arteria Cerebral Media , Encéfalo
2.
Neuroimage ; 286: 120506, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38185186

RESUMEN

Arterial spin labeling (ASL) is a promising, non-invasive perfusion magnetic resonance imaging technique for quantifying cerebral blood flow (CBF). Unfortunately, ASL suffers from an inherently low signal-to-noise ratio (SNR) and spatial resolution, undermining its potential. Increasing spatial resolution without significantly sacrificing SNR or scan time represents a critical challenge towards routine clinical use. In this work, we propose a model-based super-resolution reconstruction (SRR) method with joint motion estimation that breaks the traditional SNR/resolution/scan-time trade-off. From a set of differently oriented 2D multi-slice pseudo-continuous ASL images with a low through-plane resolution, 3D-isotropic, high resolution, quantitative CBF maps are estimated using a Bayesian approach. Experiments on both synthetic whole brain phantom data, and on in vivo brain data, show that the proposed SRR Bayesian estimation framework outperforms state-of-the-art ASL quantification.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Angiografía por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Marcadores de Spin , Teorema de Bayes , Angiografía por Resonancia Magnética/métodos , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Relación Señal-Ruido , Imagen por Resonancia Magnética/métodos
3.
Magn Reson Med ; 91(6): 2320-2331, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38173296

RESUMEN

PURPOSE: Background suppression (BS) is recommended in arterial spin labeling (ASL) for improved SNR but is difficult to optimize in existing velocity-selective ASL (VSASL) methods. Dual-module VSASL (dm-VSASL) enables delay-insensitive, robust, and SNR-efficient perfusion imaging, while allowing efficient BS, but its optimization has yet to be thoroughly investigated. METHODS: The inversion effects of the velocity-selective labeling pulses, such as velocity-selective inversion (VSI), can be used for BS, and were modeled for optimizing BS in dm-VSASL. In vivo experiments using dual-module VSI (dm-VSI) were performed to compare two BS strategies: a conventional one with additional BS pulses and a new one without any BS pulse. Their BS performance, temporal noise, and temporal SNR were examined and compared, with pulsed and pseudo-continuous ASL (PASL and PCASL) as the reference. RESULTS: The in vivo experiments validated the BS modeling. Strong positive linear correlations (r > 0.82, p < 0.0001) between the temporal noise and the tissue signal were found in PASL/PCASL and dm-VSI. Optimal BS can be achieved with and without additional BS pulses in dm-VSI; the latter improved the ASL signals by 8.5% in gray matter (p = 0.006) and 12.2% in white matter (p = 0.014) and tended to provide better temporal SNR. The dm-VSI measured significantly higher ASL signal (p < 0.016) and temporal SNR (p < 0.018) than PASL and PCASL. Complex reconstruction was found necessary with aggressive BS. CONCLUSION: Guided by modeling, optimal BS can be achieved without any BS pulse in dm-VSASL, further improving the ASL signal and the SNR performance.


Asunto(s)
Angiografía por Resonancia Magnética , Sustancia Blanca , Angiografía por Resonancia Magnética/métodos , Marcadores de Spin , Arterias/diagnóstico por imagen , Sustancia Gris , Circulación Cerebrovascular , Encéfalo/diagnóstico por imagen
4.
Magn Reson Med ; 91(5): 1743-1760, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37876299

RESUMEN

The 2015 consensus statement published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group and the European Cooperation in Science and Technology ( COST) Action ASL in Dementia aimed to encourage the implementation of robust arterial spin labeling (ASL) perfusion MRI for clinical applications and promote consistency across scanner types, sites, and studies. Subsequently, the recommended 3D pseudo-continuous ASL sequence has been implemented by most major MRI manufacturers. However, ASL remains a rapidly and widely developing field, leading inevitably to further divergence of the technique and its associated terminology, which could cause confusion and hamper research reproducibility. On behalf of the ISMRM Perfusion Study Group, and as part of the ISMRM Open Science Initiative for Perfusion Imaging (OSIPI), the ASL Lexicon Task Force has been working on the development of an ASL Lexicon and Reporting Recommendations for perfusion imaging and analysis, aiming to (1) develop standardized, consensus nomenclature and terminology for the broad range of ASL imaging techniques and parameters, as well as for the physiological constants required for quantitative analysis; and (2) provide a community-endorsed recommendation of the imaging parameters that we encourage authors to include when describing ASL methods in scientific reports/papers. In this paper, the sequences and parameters in (pseudo-)continuous ASL, pulsed ASL, velocity-selective ASL, and multi-timepoint ASL for brain perfusion imaging are included. However, the content of the lexicon is not intended to be limited to these techniques, and this paper provides the foundation for a growing online inventory that will be extended by the community as further methods and improvements are developed and established.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Imagen de Perfusión/métodos , Marcadores de Spin , Circulación Cerebrovascular/fisiología , Angiografía por Resonancia Magnética/métodos , Perfusión
5.
Magn Reson Med ; 92(3): 1095-1103, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38576077

RESUMEN

PURPOSE: To develop a method that achieves simultaneous brain and neck time-of-flight (ToF) magnetic resonance angiography (MRA) within feasible scan timeframes. METHODS: Localized quadratic (LQ) encoding is efficient for both signal-to-noise ratio (SNR) and in-flow enhancement. We proposed a spiral multiband LQ method to enable simultaneous intracranial and carotid ToF-MRA within a single scan. To address the venous signal contamination that becomes a challenge with multiband (MB) ToF, tilt-optimized non-saturated excitation (TONE) and partial-Fourier slice selection (PFSS) were further introduced in the LQ framework to mitigate the venous signal and improve artery contrast. A sequential spiral MB and LQ reconstruction pipeline was employed to obtain the brain-and-neck image volumes. RESULTS: The proposed MB method was able to achieve simultaneous brain and neck ToF-MRA within a 2:50-min scan. The complementarily boosted SNR-efficiency by MB and LQ acquisitions allows for the increased spatial coverage without increase in scan time or noticeable compromise in SNR. The incorporation of both TONE and PFSS effectively alleviated the venous contamination with improved small vessel sensitivity. Selection of scan parameters such as the LQ factor and flip angle reflected the trade-off among SNR, blood contrast, and venous suppression. CONCLUSIONS: A novel MB spiral LQ approach was proposed to enable fast intracranial and carotid ToF-MRA with minimized venous corruption. The method has shown promise in MRA applications where large spatial coverage is necessary.


Asunto(s)
Encéfalo , Angiografía por Resonancia Magnética , Cuello , Relación Señal-Ruido , Humanos , Angiografía por Resonancia Magnética/métodos , Cuello/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Arterias Carótidas/diagnóstico por imagen , Adulto , Masculino
6.
Magn Reson Med ; 92(4): 1568-1583, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38767321

RESUMEN

PURPOSE: To improve the spatial resolution and repeatability of a non-contrast MRI technique for simultaneous time resolved 3D angiography and perfusion imaging by developing an efficient 3D cone trajectory design. METHODS: A novel parameterized 3D cone trajectory design incorporating the 3D golden angle was integrated into 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) to achieve higher spatial resolution and sampling efficiency for both dynamic angiography and perfusion imaging with flexible spatiotemporal resolution. Numerical simulations and physical phantom scanning were used to optimize the cone design. Eight healthy volunteers were scanned to compare the original radial trajectory in 4D CAPRIA with our newly designed cone trajectory. A locally low rank reconstruction method was used to leverage the complementary k-space sampling across time. RESULTS: The improved sampling in the periphery of k-space obtained with the optimized 3D cone trajectory resulted in improved spatial resolution compared with the radial trajectory in phantom scans. Improved vessel sharpness and perfusion visualization were also achieved in vivo. Less dephasing was observed in the angiograms because of the short TE of our cone trajectory and the improved k-space sampling efficiency also resulted in higher repeatability compared to the original radial approach. CONCLUSION: The proposed 3D cone trajectory combined with 3D golden angle ordering resulted in improved spatial resolution and image quality for both angiography and perfusion imaging and could potentially benefit other applications that require an efficient sampling scheme with flexible spatial and temporal resolution.


Asunto(s)
Imagenología Tridimensional , Angiografía por Resonancia Magnética , Fantasmas de Imagen , Marcadores de Spin , Humanos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Adulto , Masculino , Algoritmos , Femenino , Imagen de Perfusión/métodos , Voluntarios Sanos , Procesamiento de Imagen Asistido por Computador/métodos , Simulación por Computador
7.
Magn Reson Med ; 92(2): 469-495, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38594906

RESUMEN

Accurate assessment of cerebral perfusion is vital for understanding the hemodynamic processes involved in various neurological disorders and guiding clinical decision-making. This guidelines article provides a comprehensive overview of quantitative perfusion imaging of the brain using multi-timepoint arterial spin labeling (ASL), along with recommendations for its acquisition and quantification. A major benefit of acquiring ASL data with multiple label durations and/or post-labeling delays (PLDs) is being able to account for the effect of variable arterial transit time (ATT) on quantitative perfusion values and additionally visualize the spatial pattern of ATT itself, providing valuable clinical insights. Although multi-timepoint data can be acquired in the same scan time as single-PLD data with comparable perfusion measurement precision, its acquisition and postprocessing presents challenges beyond single-PLD ASL, impeding widespread adoption. Building upon the 2015 ASL consensus article, this work highlights the protocol distinctions specific to multi-timepoint ASL and provides robust recommendations for acquiring high-quality data. Additionally, we propose an extended quantification model based on the 2015 consensus model and discuss relevant postprocessing options to enhance the analysis of multi-timepoint ASL data. Furthermore, we review the potential clinical applications where multi-timepoint ASL is expected to offer significant benefits. This article is part of a series published by the International Society for Magnetic Resonance in Medicine (ISMRM) Perfusion Study Group, aiming to guide and inspire the advancement and utilization of ASL beyond the scope of the 2015 consensus article.


Asunto(s)
Encéfalo , Circulación Cerebrovascular , Marcadores de Spin , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Circulación Cerebrovascular/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Perfusión
8.
Magn Reson Med ; 92(2): 761-771, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38523590

RESUMEN

PURPOSE: This study evaluated the velocity-selective (VS) MRA with different VS labeling modules, including double refocused hyperbolic tangent, eight-segment B1-insensitive rotation, delay alternating with nutation for tailored excitation, Fourier transform-based VS saturation, and Fourier transform-based inversion. METHODS: These five VS labeling modules were evaluated first through Bloch simulations, and then using VSMRA directly on various cerebral arteries of healthy subjects. The relative signal ratios from arterial ROIs and surrounding tissues as well as relative arteria-tissue contrast ratios of different methods were compared. RESULTS: Double refocused hyperbolic tangent and eight-segment B1-insensitive rotation showed very similar labeling effects. Delay alternating with nutation for tailored excitation yielded high arterial signal but with residual tissue signal due to the spatial banding effect. Fourier transform-based VS saturation with half the time of other techniques serves as an efficient nonsubtractive VSMRA method, but the remaining tissue signal still obscured some small distal arteries that were delineated by other subtraction-based VSMRA, allowing more complete cancelation of static tissue. Fourier transform-based inversion produced the highest arterial signal in VSMRA with minimal tissue background. CONCLUSION: This is the first study that angiographically compared five different VS labeling modules. Their labeling characteristics on arteries and tissue and implications for VSMRA and VS arterial spin labeling are discussed.


Asunto(s)
Arterias Cerebrales , Análisis de Fourier , Angiografía por Resonancia Magnética , Humanos , Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/fisiología , Angiografía por Resonancia Magnética/métodos , Adulto , Masculino , Femenino , Algoritmos , Velocidad del Flujo Sanguíneo/fisiología , Marcadores de Spin , Angiografía Cerebral/métodos , Circulación Cerebrovascular/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Asistida por Computador/métodos
9.
Magn Reson Med ; 92(1): 158-172, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38411277

RESUMEN

PURPOSE: Abnormalities in cerebral veins are a common finding in many neurological diseases, yet there is a scarcity of MRI techniques to assess venous hemodynamic function. The present study aims to develop a noncontrast technique to measure a novel blood flow circulatory measure, venous transit time (VTT), which denotes the time it takes for water to travel from capillary to major veins. METHODS: The proposed sequence, venous transit time imaging by changes in T1 relaxation (VICTR), is based on the notion that as water molecules transition from the tissue into the veins, they undergo a change in T1 relaxation time. The validity of the measured VTT was tested by studying the VTT along the anatomically known flow trajectory of venous vessels as well as using a physiological vasoconstrictive challenge of caffeine ingestion. Finally, we compared the VTT measured with VICTR MRI to a bolus-tracking method using gadolinium-based contrast agent. RESULTS: VTT was measured to be 3116.3 ± 326.0 ms in the posterior superior sagittal sinus (SSS), which was significantly longer than 2865.0 ± 390.8 ms at the anterior superior sagittal sinus (p = 0.004). The test-retest assessment showed an interclass correlation coefficient of 0.964. VTT was significantly increased by 513.8 ± 239.3 ms after caffeine ingestion (p < 0.001). VTT measured with VICTR MRI revealed a strong correlation (R = 0.84, p = 0.002) with that measured with the contrast-based approach. VTT was found inversely correlated to cerebral blood flow and venous oxygenation across individuals. CONCLUSION: A noncontrast MRI technique, VICTR MRI, was developed to measure the VTT of the brain.


Asunto(s)
Venas Cerebrales , Imagen por Resonancia Magnética , Humanos , Masculino , Adulto , Femenino , Velocidad del Flujo Sanguíneo/fisiología , Venas Cerebrales/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Circulación Cerebrovascular/fisiología , Reproducibilidad de los Resultados , Cafeína/farmacología , Medios de Contraste , Adulto Joven , Procesamiento de Imagen Asistido por Computador/métodos , Hemodinámica , Angiografía por Resonancia Magnética/métodos
10.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38440807

RESUMEN

PURPOSE: Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T. METHODS: Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated. RESULTS: Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups. CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.


Asunto(s)
Arterias Cerebrales , Imagen por Resonancia Magnética , Flujo Pulsátil , Humanos , Femenino , Masculino , Adulto , Anciano , Reproducibilidad de los Resultados , Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/fisiología , Flujo Pulsátil/fisiología , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Adulto Joven , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Angiografía por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos
11.
NMR Biomed ; 37(4): e5079, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38054247

RESUMEN

A technique for combined time-of-flight (TOF) MR angiography (MRA) and quantitative susceptibility mapping (QSM) was developed with key features of standard three-dimensional (3D) TOF acquisitions, including multiple overlapping thin slab acquisition (MOTSA), ramped RF excitation, and venous saturation. The developed triple-echo 3D TOF-QSM sequence enabled TOF-MRA, susceptibility-weighted imaging (SWI), QSM, and R2* mapping. The effects of ramped RF, resolution, flip angle, venous saturation, and MOTSA were studied on QSM. Six volunteers were scanned at 3 T with the developed sequence, conventional TOF-MRA, and conventional SWI. Quantitative comparison of susceptibility values on QSM and normalized arterial and venous vessel-to-background contrasts on TOF and SWI were performed. The ramped RF excitation created an inherent phase variation in the raw phase. A generic correction factor was computed to remove the phase variation to obtain QSM without artifacts from the TOF-QSM sequence. No statistically significant difference was observed between the developed and standard QSM sequence for susceptibility values. However, maintaining standard TOF features led to compromises in signal-to-noise ratio for QSM and SWI, arising from the use of MOTSA rather than one large 3D slab, higher TOF spatial resolution, increased TOF background suppression due to larger flip angles, and reduced venous signal from venous saturation. In terms of vessel contrast, veins showed higher normalized contrast on SWI derived from TOF-QSM than the standard SWI sequence. While fast flowing arteries had reduced contrast compared with standard TOF-MRA, no statistical difference was observed for slow flowing arteries. Arterial contrast differences largely arise from the longer TR used in TOF-QSM over standard TOF-MRA to accommodate additional later echoes for SWI. In conclusion, although the sequence has a longer TR and slightly lower arterial contrast, provided an adequate correction is made for ramped RF excitation effects on phase, QSM may be performed from a multiecho sequence that includes all key TOF features, thus enabling simultaneous TOF-MRA, SWI, QSM, and R2* map computation.


Asunto(s)
Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Arterias , Relación Señal-Ruido , Venas/diagnóstico por imagen
12.
NMR Biomed ; 37(6): e5115, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38355219

RESUMEN

Arterial spin labeling (ASL) has been widely used to evaluate arterial blood and perfusion dynamics, particularly in the brain, but its application to the spinal cord has been limited. The purpose of this study was to optimize vessel-selective pseudocontinuous arterial spin labeling (pCASL) for angiographic and perfusion imaging of the rat cervical spinal cord. A pCASL preparation module was combined with a train of gradient echoes for dynamic angiography. The effects of the echo train flip angle, label duration, and a Cartesian or radial readout were compared to examine their effects on visualizing the segmental arteries and anterior spinal artery (ASA) that supply the spinal cord. Lastly, vessel-selective encoding with either vessel-encoded pCASL (VE-pCASL) or super-selective pCASL (SS-pCASL) were compared. Vascular territory maps were obtained with VE-pCASL perfusion imaging of the spinal cord, and the interanimal variability was evaluated. The results demonstrated that longer label durations (200 ms) resulted in greater signal-to-noise ratio in the vertebral arteries, improved the conspicuity of the ASA, and produced better quality maps of blood arrival times. Cartesian and radial readouts demonstrated similar image quality. Both VE-pCASL and SS-pCASL adequately labeled the right or left vertebral arteries, which revealed the interanimal variability in the segmental artery with variations in their location, number, and laterality. VE-pCASL also demonstrated unique interanimal variations in spinal cord perfusion with a right-sided dominance across the six animals. Vessel-selective pCASL successfully achieved visualization of the arterial inflow dynamics and corresponding perfusion territories of the spinal cord. These methodological developments provide unique insights into the interanimal variations in the arterial anatomy and dynamics of spinal cord perfusion.


Asunto(s)
Angiografía por Resonancia Magnética , Ratas Sprague-Dawley , Animales , Masculino , Angiografía por Resonancia Magnética/métodos , Imagen de Perfusión/métodos , Marcadores de Spin , Ratas , Médula Cervical/diagnóstico por imagen , Médula Cervical/irrigación sanguínea , Médula Espinal/irrigación sanguínea , Médula Espinal/diagnóstico por imagen
13.
J Magn Reson Imaging ; 59(3): 797-811, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37589377

RESUMEN

Perforator flap magnetic resonance angiography (MRA) has emerged as a widely accepted and preferred modality for perforator flap mapping at several institutions. Autologous perforator flaps are a type of reconstructive microsurgical technique that involves transferring skin and fat from one part of the patient's body to another to replace tissue lost due to trauma, cancer resection, or other reasons. Autologous perforator flaps are based on a specific perforating blood vessel perfusing the transferred tissue. Hence, the surgery relies on the precise identification and mapping of perforating vessels to ensure successful outcomes. With its superior soft tissue contrast and multiplanar imaging capabilities, MRA has shown great potential in providing accurate and detailed visualization of perforator anatomy, size, and course. This review article summarizes the current literature on perforator flap MRA, including its technical considerations, imaging protocols, postprocessing, and reporting, specifically for autologous breast reconstructions. The advantages and limitations of MRA in evaluating perforator flaps are discussed, including its role in preoperative planning, intraoperative guidance, and postoperative assessment. Anatomy, brief surgical technique, specific technical modifications, and reporting of most commonly performed autologous breast flaps are described. Recent advancements in Perforator flap surgery and MRA techniques are discussed. Additionally, we examine the emerging role of artificial intelligence and machine learning in improving the accuracy and efficiency of perforator flap MRA interpretation. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 5.


Asunto(s)
Mamoplastia , Colgajo Perforante , Humanos , Angiografía por Resonancia Magnética/métodos , Inteligencia Artificial , Arterias Epigástricas/patología , Mamoplastia/métodos
14.
J Magn Reson Imaging ; 59(5): 1612-1619, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37515312

RESUMEN

BACKGROUND: Intracranial vessel tortuosity is a key component of dolichoectasia and has been associated with atherosclerosis and adverse neurologic outcomes. However, the evaluation of tortuosity is mainly a descriptive assessment. PURPOSE: To compare the performance of three automated tortuosity metrics (angle metric [AM], distance metric [DM], and distance-to-axis metric [DTA]) for detection of dolichoectasia and presence of segment-specific plaques. STUDY TYPE: Observational, cross-sectional metric assessment. POPULATION: 1899 adults from the general population; mean age = 76 years, female = 59%, and black = 29%. FIELD STRENGTH/SEQUENCE: 3-T, three-dimensional (3D) time-of-flight MRA and 3D vessel wall MRI. ASSESSMENT: Tortuosity metrics and mean luminal area were quantified for designated segments of the internal carotid artery, middle cerebral artery, anterior cerebral artery, posterior cerebral artery, vertebral artery, and entire length of basilar artery (BA). Qualitative interpretations of BA dolichoectasia were assessed based on Smoker's visual criteria. STATISTICAL TESTS: Descriptive statistics (2-sample t-tests, Pearson chi-square tests) for group comparisons. Receiver operating characteristics area under the curve (AUC) for detection of BA dolichoectasia or segment-specific plaque. Model inputs included 1) tortuosity metrics, 2) mean luminal area, and 3) demographics (age, race, and sex). RESULTS: Qualitative dolichoectasia was identified in 336 (18%) participants, and atherosclerotic plaques were detected in 192 (10%) participants. AM-, DM-, and DTA-calculated tortuosity were good individual discriminators of basilar dolichoectasia (AUCs: 0.76, 0.74, and 0.75, respectively), with model performance improving with the mean lumen area: (AUCs: 0.88, 0.87, and 0.87, respectively). Combined characteristics (tortuosity and mean luminal area) identified plaques with better performance in the anterior (AUCs ranging from 0.66 to 0.78) than posterior (AUCs ranging from 0.54 to 0.65) circulation, with all models improving by the addition of demographics (AUCs ranging from 0.62 to 0.84). DATA CONCLUSION: Quantitative vessel tortuosity metrics yield good diagnostic accuracy for the detection of dolichoectasia. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Aterosclerosis , Placa Aterosclerótica , Insuficiencia Vertebrobasilar , Adulto , Humanos , Femenino , Anciano , Arteria Basilar , Imagen por Resonancia Magnética , Aterosclerosis/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos
15.
J Magn Reson Imaging ; 60(3): 889-899, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38131254

RESUMEN

BACKGROUND: Progression of intracranial atherosclerotic disease (ICAD) is associated with ischemic stroke events and can be quantified with three-dimensional (3D) intracranial vessel wall (IVW) MRI. However, longitudinal 3D IVW studies are limited and ICAD evolution remains relatively unknown. PURPOSE: To evaluate ICAD changes longitudinally and to characterize the imaging patterns of atherosclerotic plaque evolution. STUDY TYPE: Prospective. POPULATION: 37 patients (69 ± 12 years old, 12 females) with angiography confirmed ICAD. FIELD STRENGTH/SEQUENCE: 3.0T/3D time-of-flight gradient echo sequence and T1- and proton density-weighted fast spin echo sequences. ASSESSMENT: Each patient underwent baseline and 1-year follow-up IVW. Then, IVW data from both time points were jointly preprocessed using a multitime point, multicontrast, and multiplanar viewing workflow (known as MOCHA). Lumen and outer wall of plaques were traced and measured, and plaques were then categorized into progression, stable, and regression groups based on changes in plaque wall thickness. Patient demographic and clinical data were collected. Culprit plaques were identified based on cerebral ischemic infarcts. STATISTICAL TESTS: Generalized estimating equations-based linear and logistic regressions were used to assess associations between vascular risk factors, medications, luminal stenosis, IVW plaque imaging features, and longitudinal changes. A two-sided P-value<0.05 was considered statistically significant. RESULTS: Diabetes was significantly associated with ICAD progression, resulting in 6.6% decrease in lumen area and 6.7% increase in wall thickness at 1-year follow-up. After accounting for arterial segments, baseline contrast enhancement predicted plaque progression (odds ratio = 3.61). Culprit plaques experienced an average luminal expansion of 10.9% after 1 year. 74% of the plaques remained stable during follow-up. The regression group (18 plaques) showed significant increase in minimum lumen area (from 7.4 to 8.3 mm2), while the progression group (13 plaques) showed significant decrease in minimum lumen area (from 5.4 to 4.3 mm2). DATA CONCLUSION: Longitudinal 3D IVW showed ICAD remodeling on the lumen side. Culprit plaques demonstrated longitudinal luminal expansion compared with their non-culprit counterparts. Baseline plaque contrast enhancement and diabetes mellitus were found to be significantly associated with ICAD changes. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Progresión de la Enfermedad , Arteriosclerosis Intracraneal , Imagen por Resonancia Magnética , Placa Aterosclerótica , Humanos , Femenino , Masculino , Estudios Prospectivos , Anciano , Placa Aterosclerótica/diagnóstico por imagen , Arteriosclerosis Intracraneal/diagnóstico por imagen , Persona de Mediana Edad , Estudios Longitudinales , Imagen por Resonancia Magnética/métodos , Arterias Cerebrales/diagnóstico por imagen , Imagenología Tridimensional , Angiografía por Resonancia Magnética/métodos , Remodelación Vascular , Anciano de 80 o más Años
16.
Eur Radiol ; 34(4): 2407-2415, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37736805

RESUMEN

OBJECTIVES: To evaluate the application of black-blood CT (BBCT) in carotid artery wall imaging and its accuracy in disclosing stenosis rate and plaque burden of carotid artery. METHODS: A total of 110 patients underwent contrast-enhanced CT scan with two phases, and BBCT images were obtained using contrast-enhancement (CE)-boost technology. Two radiologists independently scored subjective image quality on black-blood computerized tomography (BBCT) images using a 4-point scale and then further analyzed plaque types. The artery stenosis rate on BBCT was measured and compared with CTA. The plaque burden on BBCT was compared with that on high-resolution intracranial vessel wall MR imaging (VW-MR imaging). The kappa value and intraclass correlation coefficient (ICC) were used for consistency analysis. The diagnostic accuracy of BBCT for stenosis rate and plaque burden greater than 50% was evaluated by AUC. RESULTS: The subjective image quality scores of BBCT had good consistency between the two readers (ICC = 0.836, p < 0.001). BBCT and CTA had a good consistency in the identification of stenosis rate (p < 0.001). There was good consistency between BBCT and VW-MR in diagnosis of plaque burden (p < 0.001). As for plaque burden over 50%, BBCT had good sensitivity (93.10%) and specificity (73.33%), with an AUC of 0.950 (95%CI 0.838-0.993). Compared with CTA, BBCT had higher consistency with VW-MR in disclosing low-density plaques and mixed plaques (ICC = 0.931 vs 0.858, p < 0.001). CONCLUSIONS: BBCT can not only display the carotid artery wall clearly but also accurately diagnose the stenosis rate and plaque burden of carotid artery. CLINICAL RELEVANCE STATEMENT: Black-blood CT, as a novel imaging technology, can assist clinicians and radiologists in better visualizing the structure of the vessel wall and plaques, especially for patients with contraindication to MRI. KEY POINTS: • Black-blood CT can clearly visualize the carotid artery wall and plaque burden. • Black-blood CT is superior to conventional CTA with more accurate diagnosis of the carotid stenosis rate and plaque burden features.


Asunto(s)
Estenosis Carotídea , Placa Aterosclerótica , Humanos , Angiografía por Resonancia Magnética/métodos , Constricción Patológica , Arterias Carótidas/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Placa Aterosclerótica/diagnóstico , Tomografía Computarizada por Rayos X/métodos
17.
Eur Radiol ; 34(8): 5179-5189, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38172442

RESUMEN

OBJECTIVES: Intracranial vessel wall enhancement (VWE) on high-resolution magnetic resonance imaging (HRMRI) is associated with the progression and poor prognosis of moyamoya disease (MMD). This study assessed potential risk factors for VWE in MMD. METHODS: We evaluated MMD patients using HRMRI and traditional angiography examinations. The participants were divided into VWE and non-VWE groups based on HRMRI. Logistic regression was performed to compare the risk factors for VWE in MMD. The incidence of cerebrovascular events of the different subgroups according to risk factors was compared using Kaplan-Meier survival and Cox regression. RESULTS: We included 283 MMD patients, 84 of whom had VWE on HRMRI. The VWE group had higher modified Rankin Scale scores at admission (p = 0.014) and a higher incidence of ischaemia and haemorrhage (p = 0.002) than did the non-VWE group. Risk factors for VWE included the ring finger protein 213 (RNF213) p.R4810K variant (odds ratio [OR] 2.01, 95% confidence interval [CI] 1.08-3.76, p = 0.028), hyperhomocysteinaemia (HHcy) (OR 5.08, 95% CI 2.34-11.05, p < 0.001), and smoking history (OR 3.49, 95% CI 1.08-11.31, p = 0.037). During the follow-up of 63.9 ± 13.2 months (median 65 months), 18 recurrent stroke events occurred. Cox regression showed that VWE and the RNF213 p.R4810K variant were risk factors for stroke. CONCLUSION: The RNF213 p.R4810K variant is strongly associated with VWE and poor prognosis in MMD. HHcy and smoking are independent risk factors for VWE. CLINICAL RELEVANCE STATEMENT: Vessel wall enhancement in moyamoya disease is closely associated with poor prognosis, especially related to the ring finger protein 213 p.R4810K variant, hyperhomocysteinaemia, and smoking, providing crucial risk assessment information for the clinic. KEY POINTS: • The baseline presence of vessel wall enhancement is significantly associated with poor prognosis in moyamoya disease. • The ring finger protein 213 p.R4810K variant is strongly associated with vessel wall enhancement and poor prognosis in moyamoya disease. • Hyperhomocysteinaemia and smoking are independent risk factors for vessel wall enhancement in moyamoya disease.


Asunto(s)
Enfermedad de Moyamoya , Humanos , Enfermedad de Moyamoya/diagnóstico por imagen , Masculino , Femenino , Factores de Riesgo , Adulto , Persona de Mediana Edad , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Adenosina Trifosfatasas/genética , Pronóstico , Estudios Retrospectivos , Hiperhomocisteinemia/complicaciones , Ubiquitina-Proteína Ligasas
18.
Eur Radiol ; 34(2): 833-841, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37580600

RESUMEN

OBJECTIVE: This study aimed to compare the efficacy of enhanced 3D T1-weighted black-blood fast-spin-echo vessel wall magnetic resonance imaging (eVW-MRI) and time-of-flight magnetic resonance angiography (TOF MRA) for follow-up evaluation of aneurysms treated with flow diversion (FD). METHODS: Our study enrolled 77 patients harboring 84 aneurysms treated with FD. Follow-up was by MRI (eVW-MRI and TOF MRA) and digital subtraction angiography (DSA). Two radiologists, blinded to DSA examination results, independently evaluated the images of aneurysm occlusion and parent artery patency using the Kamran-Byrne Scale. Interobserver diagnostic agreement and intermodality diagnostic agreement were acquired. Pretreatment and follow-up aneurysm wall enhancement (AWE) patterns were collected. RESULTS: Based on the Kamran-Byrne Scale, the intermodality agreement between eVW-MRI and DSA was better than TOF MRA versus DSA for aneurysm remnant detection (weighted ĸ = 0.891 v. 0.553) and parent artery patency (ĸ = 0.950 v. 0.221). Even with the coil artifact, the consistency of eVW-MRI with DSA for aneurysm remnant detection was better than that of TOF MRA (weighted ĸ = 0.891 v. 0.511). The artifact of adjunctive coils might be more likely to affect the accuracy in evaluating parent artery patency with TOF MRA than with eVW-MRI (ĸ = 0.077 v. 0.788). The follow-up AWE patterns were not significantly associated with pretreatment AWE patterns and aneurysm occlusion. CONCLUSIONS: The eVW-MRI outperforms TOF MRA as a reliable noninvasive and nonionizing radioactive imaging method for evaluating aneurysm remnants and parent artery patency after FD. The significance of enhancement patterns on eVW-MRI sequences needs more exploration. CLINICAL RELEVANCE STATEMENT: The application of enhanced vessel wall magnetic resonance imaging has proven to be a promising tool to depict aneurysm remnant and parent artery stenosis in order to tailor the antiplatelet therapy strategy in patients after flow diversion. KEY POINTS: • Enhanced vessel wall magnetic resonance imaging has an emerging role in depicting aneurysm remnant and parent artery patency after flow diversion. • With or without the artifact from adjunctive coils, enhanced vessel wall magnetic resonance imaging was better than TOF MRA in detecting aneurysm residual and parent artery stenosis by using DSA imaging as the standard. • Enhanced vessel wall magnetic resonance imaging holds potential to be used as an alternative to DSA for routine aneurysm follow-up after flow diversion.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Estudios de Seguimiento , Resultado del Tratamiento , Constricción Patológica/terapia , Embolización Terapéutica/métodos , Imagen por Resonancia Magnética , Angiografía por Resonancia Magnética/métodos , Angiografía de Substracción Digital/métodos
19.
Eur Radiol ; 34(7): 4831-4840, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38172441

RESUMEN

OBJECTIVES: Significant atherosclerotic stenosis or occlusion in the distal internal carotid artery (ICA) may induce diffuse wall thickening (DWT) in the upstream arterial wall. This study aimed to assess the association of atherosclerotic steno-occlusive diseases in the distal ICA with DWT in the upstream ipsilateral ICA. METHODS: Individuals with atherosclerotic stenosis in the distal ICA, detected by carotid MR vessel wall imaging using 3D pre- and post-contrast T1 volume isotropic turbo spin-echo acquisition (T1-VISTA) sequence, were enrolled. The associations of vessel wall thickening, the longitudinal extent of DWT, enhancement of the upstream ipsilateral ICA, and stenosis degree in the distal ICA were examined. RESULTS: Totally 64 arteries in 55 patients with atherosclerotic steno-occlusive distal ICAs were included. Significant correlations were found between distal ICA stenosis and DWT in the petrous ICA (r = 0.422, p = 0.001), DWT severity (r = 0.474, p < 0.001), the longitudinal extent of DWT in the ICA (r = 0.671, p < 0.001), enhancement in the petrous ICA (r = 0.409, p = 0.001), and enhancement degree (r = 0.651, p < 0.001). In addition, high degree of enhancement was correlated with both increased wall thickness and increased prevalence of DWT in the petrous ICA (both p < 0.001). CONCLUSIONS: DWT of the petrous ICA is commonly detected in patients with atherosclerotic steno-occlusive disease in the distal ICA. The degree of stenosis in the distal ICA is associated with wall thickening and its longitudinal extent in the upstream segments. CLINICAL RELEVANCE STATEMENT: Diffuse wall thickening is a common secondary change in atherosclerotic steno-occlusive disease in the intracranial carotid. This phenomenon constitutes a confounding factor in the distinction between atherosclerosis and inflammatory vasculopathies, and could be reversed after alleviated atherosclerotic stenosis. KEY POINTS: • Diffuse wall thickening of the petrous internal carotid artery is commonly detected in patients with atherosclerotic steno-occlusive disease in the distal internal carotid artery. • The phenomenon of diffuse wall thickening could be reversed after stenosis alleviation. • Carotid artery atherosclerosis with diffuse wall thickening should warrant a differential diagnosis from other steno-occlusive diseases, including moyamoya diseases and Takayasu aortitis.


Asunto(s)
Arteria Carótida Interna , Estenosis Carotídea , Humanos , Femenino , Masculino , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/complicaciones , Persona de Mediana Edad , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/patología , Anciano , Angiografía por Resonancia Magnética/métodos , Adulto , Imagenología Tridimensional/métodos , Anciano de 80 o más Años
20.
Eur Radiol ; 34(7): 4610-4618, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38108888

RESUMEN

OBJECTIVES: In patients with an unruptured intracranial aneurysm, gadolinium enhancement of the aneurysm wall is associated with growth and rupture. However, most previous studies did not have a longitudinal design and did not adjust for aneurysm size, which is the main predictor of aneurysm instability and the most important determinant of wall enhancement. We investigated whether aneurysm wall enhancement predicts aneurysm growth and rupture during follow-up and whether the predictive value was independent of aneurysm size. MATERIALS AND METHODS: In this multicentre longitudinal cohort study, individual patient data were obtained from twelve international cohorts. Inclusion criteria were as follows: 18 years or older with ≥ 1 untreated unruptured intracranial aneurysm < 15 mm; gadolinium-enhanced aneurysm wall imaging and MRA at baseline; and MRA or rupture during follow-up. Patients were included between November 2012 and November 2019. We calculated crude hazard ratios with 95%CI of aneurysm wall enhancement for growth (≥ 1 mm increase) or rupture and adjusted for aneurysm size. RESULTS: In 455 patients (mean age (SD), 60 (13) years; 323 (71%) women) with 559 aneurysms, growth or rupture occurred in 13/194 (6.7%) aneurysms with wall enhancement and in 9/365 (2.5%) aneurysms without enhancement (crude hazard ratio 3.1 [95%CI: 1.3-7.4], adjusted hazard ratio 1.4 [95%CI: 0.5-3.7]) with a median follow-up duration of 1.2 years. CONCLUSIONS: Gadolinium enhancement of the aneurysm wall predicts aneurysm growth or rupture during short-term follow-up, but not independent of aneurysm size. CLINICAL RELEVANCE STATEMENT: Gadolinium-enhanced aneurysm wall imaging is not recommended for short-term prediction of growth and rupture, since it appears to have no additional value to conventional predictors. KEY POINTS: • Although aneurysm wall enhancement is associated with aneurysm instability in cross-sectional studies, it remains unknown whether it predicts risk of aneurysm growth or rupture in longitudinal studies. • Gadolinium enhancement of the aneurysm wall predicts aneurysm growth or rupture during short-term follow-up, but not when adjusting for aneurysm size. • While gadolinium-enhanced aneurysm wall imaging is not recommended for short-term prediction of growth and rupture, it may hold potential for aneurysms smaller than 7 mm.


Asunto(s)
Aneurisma Roto , Medios de Contraste , Gadolinio , Aneurisma Intracraneal , Angiografía por Resonancia Magnética , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Femenino , Masculino , Estudios Longitudinales , Aneurisma Roto/diagnóstico por imagen , Persona de Mediana Edad , Angiografía por Resonancia Magnética/métodos , Anciano , Estudios de Cohortes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA