Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.331
Filtrar
Más filtros

Intervalo de año de publicación
1.
Ann Surg Oncol ; 31(7): 4713-4723, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38578552

RESUMEN

BACKGROUND: About 5% of Wilms tumors present with vascular extension, which sometimes extends to the right atrium. Vascular extension does not affect the prognosis, but impacts the surgical strategy, which is complex and not fully standardized. Our goal is to identify elements of successful surgical management of Wilms tumors with vascular extensions. PATIENTS AND METHODS: A retrospective study of pediatric Wilms tumors treated at three sites (January 1999-June 2019) was conducted. The inclusion criterion was the presence of a renal vein and vena cava thrombus at diagnosis. Tumor stage, pre and postoperative treatment, preoperative imaging, operative report, pathology, operative complications, and follow-up data were reviewed. RESULTS: Of the 696 pediatric patients with Wilms tumors, 69 (9.9%) met the inclusion criterion. In total, 24 patients (37.5%) had a right atrial extension and two presented with Budd-Chiari syndrome at diagnosis. Two died at diagnosis owing to pulmonary embolism. All patients received neoadjuvant chemotherapy and thrombus regressed in 35.6% of cases. Overall, 14 patients had persistent intra-atrial thrombus extension (58%) and underwent cardiopulmonary bypass. Most thrombi (72%) were removed intact with nephrectomy. Massive intraoperative bleeding occurred during three procedures. Postoperative renal insufficiency was identified as a risk factor for patient survival (p = 0.01). With a median follow-up of 9 years (range: 0.5-20 years), overall survival was 89% and event-free survival was 78%. CONCLUSIONS: Neoadjuvant chemotherapy with proper surgical strategy resulted in a survival rate comparable to that of children with Wilms tumors without intravascular extension. Clinicians should be aware that postoperative renal insufficiency is associated with worse survival outcomes.


Asunto(s)
Neoplasias Renales , Nefrectomía , Venas Renales , Tumor de Wilms , Humanos , Tumor de Wilms/cirugía , Tumor de Wilms/patología , Femenino , Masculino , Estudios Retrospectivos , Neoplasias Renales/cirugía , Neoplasias Renales/patología , Preescolar , Niño , Lactante , Estudios de Seguimiento , Tasa de Supervivencia , Pronóstico , Venas Renales/cirugía , Venas Renales/patología , Atrios Cardíacos/cirugía , Atrios Cardíacos/patología , Terapia Neoadyuvante , Vena Cava Inferior/patología , Vena Cava Inferior/cirugía
2.
J Cardiovasc Electrophysiol ; 35(1): 171-181, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38018401

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is accompanied by various types of remodeling, including volumetric enlargement and histological degeneration. Electrical remodeling reportedly reflects histological degeneration. PURPOSE: To clarify the differences in determinants and clinical impacts among types of remodeling. METHODS: This observational study included 1118 consecutive patients undergoing initial ablation for AF. Patients were divided into four groups: minimal remodeling (left atrial volume index [LAVI] < mean value and no low-voltage area [LVA], n = 477); volumetric remodeling (LAVI ≥ mean value and no LVA, n = 361); electrical remodeling (LAVI < mean value and LVA presence, n = 96); and combined remodeling (LAVI ≥ mean value and LVA presence, n = 184). AF recurrence and other clinical outcomes were followed up for 2 and 5 years, respectively. RESULTS: Major determinants of each remodeling pattern were high age for electrical (odds ratio = 2.32, 95% confidence interval = 1.68-3.25) and combined remodeling (2.57, 1.88-3.49); female for electrical (3.85, 2.21-6.71) and combined remodeling (4.92, 2.90-8.25); persistent AF for combined remodeling (7.09, 3.75-13.4); and heart failure for volumetric (1.71, 1.51-2.53) and combined remodeling (2.21, 1.30-3.75). Recurrence rate after initial ablation increased in the order of minimal remodeling (20.1%), volumetric (27.4%) or electrical remodeling (36.5%), and combined remodeling (50.0%, p < .0001). A composite endpoint of heart failure, stroke, and death occurred in the order of minimal (3.4%), volumetric (7.5%) or electrical (8.3%), and combined remodeling (15.2%, p < .0001). CONCLUSION: Volumetric, electrical, and combined remodeling were each associated with a unique patient background, and defined rhythm and other clinical outcomes.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Remodelación Atrial , Insuficiencia Cardíaca , Femenino , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Recurrencia , Resultado del Tratamiento , Masculino
3.
J Cardiovasc Electrophysiol ; 35(4): 811-820, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38424601

RESUMEN

INTRODUCTION: Various left atrial (LA) anatomical structures are correlated with postablative recurrence for atrial fibrillation (AF) patients. Comprehensively integrating anatomical structures, digitizing them, and implementing in-depth analysis, which may supply new insights, are needed. Thus, we aim to establish an interpretable model to identify AF patients' phenotypes according to LA anatomical morphology, using machine learning techniques. METHODS AND RESULTS: Five hundred and nine AF patients underwent first ablation treatment in three centers were included and were followed-up for postablative recurrent atrial arrhythmias. Data from 369 patients were regarded as training set, while data from another 140 patients, collected from different centers, were used as validation set. We manually measured 57 morphological parameters on enhanced computed tomography with three-dimensional reconstruction technique and implemented unsupervised learning accordingly. Three morphological groups were identified, with distinct prognosis according to Kaplan-Meier estimator (p < .001). Multivariable Cox model revealed that morphological grouping were independent predictors of 1-year recurrence (Group 1: HR = 3.00, 95% CI: 1.51-5.95, p = .002; Group 2: HR = 4.68, 95% CI: 2.40-9.11, p < .001; Group 3 as reference). Furthermore, external validation consistently demonstrated our findings. CONCLUSIONS: Our study illustrated the feasibility of employing unsupervised learning for the classification of LA morphology. By utilizing morphological grouping, we can effectively identify individuals at different risks of postablative recurrence and thereby assist in clinical decision-making.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
4.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38556747

RESUMEN

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Asunto(s)
Fibrilación Atrial , Criocirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Criocirugía/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Potenciales de Acción , Frecuencia Cardíaca , Factores de Tiempo , Estudios Retrospectivos , Recurrencia , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología
5.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38519418

RESUMEN

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Anciano , Estudios Prospectivos , Factores de Tiempo , Italia , Factores de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Resultado del Tratamiento , Supervivencia sin Progresión
6.
J Cardiovasc Electrophysiol ; 35(6): 1140-1149, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38561951

RESUMEN

INTRODUCTION: The presence of low-voltage zones (LVZs) in the left atrium (LA) is associated with the recurrence of atrial fibrillation (AF) following pulmonary vein isolation (PVI). However, there is variability and conflict in the data regarding predictors of LVZs as reported in previous studies. The objective of this study was to identify predictors for the presence of LVZs in a cohort of patients with persistent AF. METHODS: The study prospectively enrolled 439 patients with persistent AF who were scheduled for ablation. Voltage map of the LA was collected using a multipolar catheter. An LVZ was defined as an area of ≥3 cm2 exhibiting a peak-to-peak bipolar voltage of <0.5 mV. RESULTS: The mean age of the cohort was 65.3 ± 8.6 years and 26.4% were female. Additionally, 25.7% had significant LVZs, most frequently located in the anterior wall of the LA. Multivariable analysis identified the following independent predictors for LVZ: advanced age (OR [odds ratio] = 1.08, 95% CI [confidence interval] = 1.03-1.13, p = .002); female sex (OR = 4.83, 95% CI = 2.66-8.76, p < .001); coronary artery disease (CAD) (OR = 3.20, 95% CI = 1.32-7.77, p = .01) and enlarged LA diameter (OR = 1.10, 95% CI = 1.04-1.17, p = .001). The area under the curve (AUC) of the receiver operating characteristic (ROC) curve for the final model was 0.829. CONCLUSION: Approximately 25% of the patients with persistent AF had LVZs. Advanced age, female sex, CAD, and a larger LA were independent predictors for LVZs with the model demonstrating a very good AUC for the ROC curve. These findings hold the potential to be used to tailor the ablation procedure for the individual patient.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Medición de Riesgo , Factores Sexuales , Factores de Tiempo , Factores de Edad
7.
J Cardiovasc Electrophysiol ; 35(4): 775-784, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38375957

RESUMEN

INTRODUCTION: Left atrial low-voltage areas (LVAs) are known to be correlated with atrial scarring and atrial fibrillation (AF) recurrence after ablation. However, the association between LVAs and glycemic status before ablation has not been fully clarified. The purpose of this study was to investigate associations among the prevalence of diabetes mellitus (DM), glycemic control, and the prevalence of LVAs in patients with AF ablation. METHODS: In total, 912 (age, 68 ± 10 years; female, 299 [33%]; persistent AF, 513 [56%]) consecutive patients who underwent initial AF ablation were included. A preprocedure glycated hemoglobin A1c (HbA1c) ≥7% was set as the cutoff for poor glycemic control in patients with DM. LVAs were defined as areas with a bipolar voltage of <0.5 mV covering ≥5 cm2 of left atrium. RESULTS: LVAs existed in 208 (23%) patients, and 168 (18%) patients had DM. LVAs were found more frequently in patients with DM and poor glycemic control. On multivariate analysis, DM with HbA1c ≥7% was an independent predictor of LVAs (odds ratio, 3.3; 95% confidence interval: 1.6-6.7; p = .001). In patients with LVAs, freedom from AF recurrence during the 24-month study period was significantly lower in patients who had DM with HbA1c ≥7% than in those without DM (37.9% vs. 54.7%, p = .02). CONCLUSION: In patients with AF ablation, LVAs were found more frequently in patients with DM and poor glycemic control. DM with HbA1c ≥7% was an independent predictor of LVAs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Diabetes Mellitus , Humanos , Femenino , Persona de Mediana Edad , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Prevalencia , Hemoglobina Glucada , Control Glucémico , Atrios Cardíacos/cirugía , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiología , Diabetes Mellitus/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 35(6): 1156-1164, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38566599

RESUMEN

INTRODUCTION: Left atrial (LA) low voltage areas (LVA) are a controversial target in atrial fibrillation ablation procedures. However, LVA and LA volume are good predictors of arrhythmia recurrence in ablation-naïve patients. Their predictive value in progressively diseased pre-ablated atria is uncertain. METHODS: Consecutive patients with recurrent atrial fibrillation (AF) or atrial tachycardia (AT), who were scheduled for repeat LA ablation, were enrolled in the prospective Bernau ablation registry between 2016 and 2020. All patients received a complete LA ultrahigh-density map before ablation. Maps were analyzed for LA size, LVA percentage and distribution. The predictive value of demographic, anatomic, and mapping variables on AF recurrence was analyzed. RESULTS: 160 patients (50.6% male, 1.3 pre-ablations, 60% persistent AF) with complete LA voltage maps were included. Mean follow-up time was 16 ± 11 months. Mean recorded electrograms (EGMs) per map were 9754 ± 5808, mean LA volume was 176.1 ± 35.9 ml and mean rate of LVAs <0.5 mV was 30.6% ± 23.1%. During follow-up recurrence rate of AF or AT >30 s was 55.6%. Patients with recurrence had a significant higher percentage of LVAs (40.0% vs. 18.8%, p < .001) but no relevant difference in LA volume (172 vs. 178 mL, p = .299). ROC curves revealed LVA as a good predictor for recurrence (AUC = 0.79, p < .001) and a cut-off of 22% LVAs with highest sensitivity (73.0%) and specificity (71.8%). Based on this cut off, event free survival was significantly higher in the Low LVA group (p < .01). CONCLUSION: Total LVA percentage has a good predictive power on arrhythmia recurrence in a cohort of advanced scarred left atria in repeat procedures independent of the applied ablation strategy. Left atrial volume seems to have minor impact on the rhythm outcome in our study cohort.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Función del Atrio Izquierdo , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Recurrencia , Sistema de Registros , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Factores de Riesgo , Factores de Tiempo , Estudios Prospectivos , Reoperación , Medición de Riesgo , Resultado del Tratamiento , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiología , Remodelación Atrial
9.
J Cardiovasc Electrophysiol ; 35(8): 1525-1535, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38803029

RESUMEN

INTRODUCTION: The unique safety profile of pulsed field ablation (PFA) has made pulmonary vein isolation (PVI) + left atrial posterior wall (LAPW) ablation promising for treating persistent atrial fibrillation (PerAF). The goal of this study was to assess long-term freedom from atrial fibrillation, atrial flutter, and atrial tachycardia (AF/AFL/AT), as well as the safety and feasibility of LAPW PFA using multipolar, pentaspline Farawave catheter. METHODS: Retrospective observational study at a single institution. Data for 94 patients were collected from a prespecified intraprocedural registry. The long-term AF/AFL/AT recurrence assessment was based on an analysis of medical history; 24-h Holter ECGs at 3, 6, and 12 months postablation; and 12-lead ECGs recorded during symptomatic episodes or visits. RESULTS: Half of the patients had ls-PerAF, and half had a history of catheter ablation-mostly RF PVI. The acute ablation success rate was 100%, and the primary safety outcome was observed in 2 patients. Fifty patients experienced AF/AFL/AT recurrence (54.3%). An increase in LAPW low-voltage areas and AF classification were associated with arrhythmia recurrence. After a median follow-up of 13 months, the Kaplan‒Meier estimated median time free of AF/AFL/AT after a single procedure was 14.7 months. CONCLUSION: PFA PVI + PWA had the best outcome in perAF patients without extensive LA fibrosis. AF recurrence was paroxysmal in significant part of the cohort. The addition of PWA to PVI using multipolar PFA was safe and did not significantly influence the transpired ablation time.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Ablación por Catéter/efectos adversos , Factores de Tiempo , Factores de Riesgo , Sistema de Registros , Estudios de Factibilidad , Resultado del Tratamiento , Supervivencia sin Progresión , Aleteo Atrial/cirugía , Aleteo Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/diagnóstico , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Catéteres Cardíacos
10.
J Cardiovasc Electrophysiol ; 35(8): 1561-1569, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38818534

RESUMEN

INTRODUCTION: Esophageal safety following radiofrequency (RF) left atrial (LA) linear ablation has not been established. To determine the esophageal safety profile of LA linear RF lesions, we performed systematic esophagogastroduodenoscopy in all patients with intraesophageal temperature rise (ITR) ≥ 38.5°C. METHODS AND RESULTS: Between December 2021 and July 2023, a total of 200 consecutive patients with atrial tachyarrhythmia (ATA) underwent linear ablation with posterior dome (roof or floor) or posterior mitral isthmus line transection. Patients with ITR ≥ 38.5°C were scheduled for esophageal endoscopy ~3 weeks after ablation. Patient and ATA characteristics, procedural parameters, endoscopy findings and ablation lesion data were collected and analyzed. One hundred thirty-three out of 200 (67%) patients showed ITR ≥ 38.5°C during LA linear ablation. ITR (with maximal temperature of 45.7°C) was more frequently observed during floor line ablation (82% of cases). ITR was less observed during roof line ablation (34%) and posterior mitral isthmus ablation (4%). Endoscopy, performed in 115 patients after 24 ± 10 days, showed esophageal ulceration in four patients (two patients Kansas City classification [KCC] 2a and two patients KCC 2b). No patient showed esophageal perforation or fistula. CONCLUSION: Temperature rise during LA linear ablation is frequent and ulceration risk exists, particularly when floor line is performed. Safety measures are needed to avoid potential severe complications like esophageal perforation and fistula.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Úlcera , Humanos , Femenino , Masculino , Persona de Mediana Edad , Úlcera/diagnóstico por imagen , Úlcera/etiología , Úlcera/diagnóstico , Resultado del Tratamiento , Anciano , Medición de Riesgo , Factores de Riesgo , Ablación por Catéter/efectos adversos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Enfermedades del Esófago/etiología , Enfermedades del Esófago/diagnóstico , Factores de Tiempo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Atrios Cardíacos/diagnóstico por imagen , Endoscopía del Sistema Digestivo/efectos adversos , Estudios Retrospectivos , Esófago/lesiones
11.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38758963

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB. METHODS AND RESULTS: In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: -57 ± 34 ms, P = 0.0002; in the LA: -42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)]. CONCLUSION: Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Modelos Animales de Enfermedad , Venas Pulmonares , Animales , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/prevención & control , Fibrilación Atrial/diagnóstico , Porcinos , Ablación por Catéter/métodos , Apnea Obstructiva del Sueño/fisiopatología , Insuficiencia del Tratamiento , Frecuencia Cardíaca , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía
12.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38781099

RESUMEN

AIMS: Cardioneuroablation (CNA) is a catheter-based intervention for recurrent vasovagal syncope (VVS) that consists in the modulation of the parasympathetic cardiac autonomic nervous system. This survey aims to provide a comprehensive overview of current CNA utilization in Europe. METHODS AND RESULTS: A total of 202 participants from 40 different countries replied to the survey. Half of the respondents have performed a CNA during the last 12 months, reflecting that it is considered a treatment option of a subset of patients. Seventy-one per cent of respondents adopt an approach targeting ganglionated plexuses (GPs) systematically in both the right atrium (RA) and left atrium (LA). The second most common strategy (16%) involves LA GP ablation only after no response following RA ablation. The procedural endpoint is frequently an increase in heart rate. Ganglionated plexus localization predominantly relies on an anatomical approach (90%) and electrogram analysis (59%). Less utilized methods include pre-procedural imaging (20%), high-frequency stimulation (17%), and spectral analysis (10%). Post-CNA, anticoagulation or antiplatelet therapy is prescribed, with only 11% of the respondents discharging patients without such medication. Cardioneuroablation is perceived as effective (80% of respondents) and safe (71% estimated <1% rate of procedure-related complications). Half view CNA emerging as a first-line therapy in the near future. CONCLUSION: This survey offers a snapshot of the current implementation of CNA in Europe. The results show high expectations for the future of CNA, but important heterogeneity exists regarding indications, procedural workflow, and endpoints of CNA. Ongoing efforts are essential to standardize procedural protocols and peri-procedural patient management.


Asunto(s)
Ablación por Catéter , Síncope Vasovagal , Humanos , Síncope Vasovagal/fisiopatología , Síncope Vasovagal/cirugía , Síncope Vasovagal/diagnóstico , Europa (Continente) , Ablación por Catéter/métodos , Flujo de Trabajo , Frecuencia Cardíaca , Resultado del Tratamiento , Encuestas de Atención de la Salud , Pautas de la Práctica en Medicina/tendencias , Técnicas Electrofisiológicas Cardíacas , Encuestas y Cuestionarios , Ganglios Autónomos/cirugía , Ganglios Autónomos/fisiopatología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Recurrencia
13.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38597211

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Venas Pulmonares/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Fenotipo , Recurrencia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
14.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38652090

RESUMEN

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Atrios Cardíacos , Tomografía Computarizada Multidetector , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Venas Pulmonares/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Masculino , Ablación por Catéter/métodos , Persona de Mediana Edad , Anciano , Atrios Cardíacos/cirugía , Atrios Cardíacos/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento , Recurrencia , Frecuencia Cardíaca , Potenciales de Acción
15.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38870348

RESUMEN

AIMS: Patients with persistent atrial fibrillation (AF) experience 50% recurrence despite pulmonary vein isolation (PVI), and no consensus is established for secondary treatments. The aim of our i-STRATIFICATION study is to provide evidence for stratifying patients with AF recurrence after PVI to optimal pharmacological and ablation therapies, through in silico trials. METHODS AND RESULTS: A cohort of 800 virtual patients, with variability in atrial anatomy, electrophysiology, and tissue structure (low-voltage areas, LVAs), was developed and validated against clinical data from ionic currents to electrocardiogram. Virtual patients presenting AF post-PVI underwent 12 secondary treatments. Sustained AF developed in 522 virtual patients after PVI. Second ablation procedures involving left atrial ablation alone showed 55% efficacy, only succeeding in the small right atria (<60 mL). When additional cavo-tricuspid isthmus ablation was considered, Marshall-PLAN sufficed (66% efficacy) for the small left atria (<90 mL). For the bigger left atria, a more aggressive ablation approach was required, such as anterior mitral line (75% efficacy) or posterior wall isolation plus mitral isthmus ablation (77% efficacy). Virtual patients with LVAs greatly benefited from LVA ablation in the left and right atria (100% efficacy). Conversely, in the absence of LVAs, synergistic ablation and pharmacotherapy could terminate AF. In the absence of ablation, the patient's ionic current substrate modulated the response to antiarrhythmic drugs, being the inward currents critical for optimal stratification to amiodarone or vernakalant. CONCLUSION: In silico trials identify optimal strategies for AF treatment based on virtual patient characteristics, evidencing the power of human modelling and simulation as a clinical assisting tool.


Asunto(s)
Antiarrítmicos , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Humanos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Antiarrítmicos/uso terapéutico , Resultado del Tratamiento , Modelos Cardiovasculares , Simulación por Computador , Potenciales de Acción , Medición de Riesgo , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Masculino , Anisoles/uso terapéutico , Selección de Paciente , Femenino , Modelación Específica para el Paciente , Persona de Mediana Edad , Pirrolidinas/uso terapéutico , Electrocardiografía , Toma de Decisiones Clínicas
16.
BMC Infect Dis ; 24(1): 659, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38956482

RESUMEN

BACKGROUND: Alveolar echinococcosis (AE) primarily affects the liver and potentially spreads to other organs. Managing recurrent AE poses significant challenges, especially when it involves critical structures and multiple major organs. CASE PRESENTATION: We present a case of a 59-year-old female with recurrent AE affecting the liver, heart, and lungs following two previous hepatectomies, the hepatic lesions persisted, adhering to major veins, and imaging revealed additional diaphragmatic, cardiac, and pulmonary involvement. The ex vivo liver resection and autotransplantation (ELRA), first in human combined with right atrium (RA) reconstruction were performed utilizing cardiopulmonary bypass, and repairs of the pericardium and diaphragm. This approach aimed to offer a potentially curative solution for lesions previously considered inoperable without requiring a donor organ or immunosuppressants. The patient encountered multiple serious complications, including atrial fibrillation, deteriorated liver function, severe pulmonary infection, respiratory failure, and acute kidney injury (AKI). These complications necessitated intensive intraoperative and postoperative care, emphasizing the need for a comprehensive management strategy in such complicated high-risk surgeries. CONCLUSIONS: The multidisciplinary collaboration in this case proved effective and yielded significant therapeutic outcomes for a rare case of advanced hepatic, cardiac, and pulmonary AE. The combined approach of ELRA and RA reconstruction under extracorporeal circulation demonstrated distinct advantages of ELRA in treating complex HAE. Meanwhile, assessing diaphragm function during the perioperative period, especially in patients at high risk of developing pulmonary complications and undergoing diaphragmectomy is vital to promote optimal postoperative recovery. For multi-resistant infection, it is imperative to take all possible measures to mitigate the risk of AKI if vancomycin administration is deemed necessary.


Asunto(s)
Atrios Cardíacos , Trasplante de Hígado , Trasplante Autólogo , Humanos , Persona de Mediana Edad , Femenino , Atrios Cardíacos/cirugía , Atrios Cardíacos/parasitología , Equinococosis/cirugía , Hígado/parasitología , Hígado/cirugía , Procedimientos de Cirugía Plástica/métodos , Equinococosis Hepática/cirugía
17.
BMC Cardiovasc Disord ; 24(1): 31, 2024 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-38183012

RESUMEN

BACKGROUND: Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital cardiac anomaly, mortality rates in infancy reach approximately 90%, with only a small number of patients surviving into adulthood, therefore, most of the literature reports mainly focus on infantile type. CASE PRESENTATION: A 55-year-old female was admitted due to persistent repeated chest pain experienced and had worsened for unknown reasons. Color doppler echocardiography, coronary computed tomographic angiography, and coronary angiography confirmed the diagnosis of ALCAPA and concurrent right coronary artery-right atrial fistula. The symptoms of chest pain exhibited notable improvement subsequent to corrective surgery for the anomalous origin of the coronary artery. CONCLUSIONS: This report shows an unique case of ALCAPA in an adult patient, characterizing the condition's combination with a right coronary-right atrial fistula, and it is prone to misdiagnosis and misdiagnosis. We aim to provide valuable insights for clinical diagnosis and treatment of ALCAPA.


Asunto(s)
Síndrome de Bland White Garland , Arteria Pulmonar , Adulto , Femenino , Humanos , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Dolor en el Pecho , Angiografía Coronaria
18.
BMC Cardiovasc Disord ; 24(1): 347, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38977958

RESUMEN

BACKGROUND: CHA2DS2-VASc score-related differences have been reported in atrial fibrotic remodeling and prognosis of atrial fibrillation (AF) patients after ablation. There are currently no data on the efficacy of low voltage zone (LVZ)-guided ablation in persistent AF patients according to CHA2DS2-VASc score. We assessed in a cohort of persistent AF patients the extent of LVZ, the regional distribution of LA voltage and the outcome of LA voltage-guided substrate ablation in addition to PVI according to CHA2DS2-VASc score. METHODS: 138 consecutive persistent AF patients undergoing a first voltage-guided catheter ablation were enrolled. 58 patients with CHAD2DS2-VASc score ≥ 3 and 80 patients with CHAD2DS2-VASc score ≤ 2 were included. LA voltage maps were obtained using 3D-electroanatomical mapping system in sinus rhythm. LVZ was defined as < 0.5 mV. RESULTS: In the high CHAD2DS2-VASc score group, LA voltage was lower (1.5 [1.1-2.5] vs. 2.3 [1.5-2.8] mV, p = 0.02) and LVZs were more frequently identified (40% vs. 18%), p < 0.01). Female with CHA2DS2-VASc score ≥ 3 (p = 0.031), LA indexed volume (p = 0.009) and P-wave duration ≥ 150 ms (p = 0.001) were predictors of LVZ. After a 36-month follow-up, atrial arrhythmia-free survival was similar between the two groups (logrank test, P = 0.676). CONCLUSIONS: AF patients with CHAD2DS2-VASc score ≥ 3 display more LA substrate remodeling with lower voltage and more LVZs compared with those with CHAD2DS2-VASc score ≤ 2. Despite this atrial remodeling, they had similar and favorable 36 months results after one single procedure. Unlike male with CHAD2DS2-VASc score ≥ 3, female with CHAD2DS2-VASc score ≥ 3 was predictor of LVZ occurrence.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Función del Atrio Izquierdo , Remodelación Atrial , Ablación por Catéter , Valor Predictivo de las Pruebas , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Femenino , Masculino , Ablación por Catéter/efectos adversos , Persona de Mediana Edad , Anciano , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Frecuencia Cardíaca , Técnicas de Apoyo para la Decisión , Técnicas Electrofisiológicas Cardíacas , Recurrencia , Estudios Retrospectivos
19.
Pacing Clin Electrophysiol ; 47(3): 429-432, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-37221909

RESUMEN

Balloon-based catheter ablation including visually guided laser balloon (VGLB) has been adopted a first line therapeutic strategy for the patients with atrial fibrillation (AF). Recently, the roof area ablation beyond pulmonary vein (PV) isolation (PVI) using cryoballoon has been described as an effective therapy for the patients with persistent AF. However, the roof area ablation performed with a VGLB remains unknown. In this case, we report the case of roof area ablation for the patient with persistent AF using a VGLB.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Resultado del Tratamiento , Recurrencia , Atrios Cardíacos/cirugía , Rayos Láser , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía
20.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38523591

RESUMEN

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Asunto(s)
Fibrilación Atrial , Criocirugía , Medición de Resultados Informados por el Paciente , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Masculino , Femenino , Criocirugía/métodos , Fibrilación Atrial/cirugía , Persona de Mediana Edad , Estudios Prospectivos , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Sistema de Registros , Calidad de Vida , Anciano , Ablación por Radiofrecuencia/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA