Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.409
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Cardiothorac Vasc Anesth ; 37(1): 16-22, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36357305

RESUMEN

OBJECTIVES: To evaluate mitral-aortic flow velocity integral ratio (MAVIR) as an echocardiographic tool to differentiate between severe and nonsevere mitral regurgitation (MR), compared with regurgitant volume (RVol) and effective regurgitant orifice area (EROA), with subgroup analysis in patients with calcific mitral valve, both by transthoracic (TTE) and transesophageal (TEE) echocardiography. Also, whether MAVIR can be used as a screening tool for severe MR. DESIGN: Prospective, cross-sectional, observational. SETTING: Cardiac operating room of a tertiary-care hospital. PARTICIPANTS: One hundred adult patients with chronic mitral regurgitation with at least mild MR by two-dimensional Doppler and with absence of mitral stenosis, aortic valve disease, and rhythm other than sinus scheduled for cardiac surgery. The subgroup (n = 24) consisted specifically of patients with a calcific mitral valve. INTERVENTIONS: Preinduction TTE and postinduction TEE in the operating room. MEASUREMENTS AND RESULTS: MAVIR, RVol, and EROA were measured in all patients both by TTE and TEE. Cohen's kappa statistics was employed to quantify concordance among RVol, EROA, and MAVIR. Diagnostic indices of MAVIR toward diagnosis of severe MR also were quantified. The results showed a strong agreement, in differentiating severe from nonsevere MR, between MAVIR and both RVol and EROA in the whole cohort (n = 100) and the subgroup (n = 24), both by TTE and TEE. Diagnostic indices were high for MAVIR compared with RVol and EROA in detecting severe MR, both by TTE and TEE. CONCLUSION: MAVIR may be used as an echocardiographic tool to differentiate between severe and nonsevere MR, even in patients with calcific valves. It also can be used to screen patients for severe MR.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Adulto , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ecocardiografía Doppler en Color/métodos , Estudios Prospectivos , Estudios Transversales , Velocidad del Flujo Sanguíneo , Índice de Severidad de la Enfermedad
2.
J Obstet Gynaecol Res ; 49(7): 1743-1749, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37190899

RESUMEN

AIM: The intraventricular pressure difference (IVPD) is the pressure difference in early diastole from the base to the apex of the ventricle. It is a useful marker for evaluating diastolic function because of its role as a suction force. This study investigated the changes in total and segmental IVPDs in normal fetuses throughout gestation to obtain normative data equations. METHODS: One hundred thirty-seven healthy pregnant women at 12-40 weeks of gestation were prospectively enrolled to evaluate IVPD. The color M mode was performed, and the image was evaluated using our own code to calculate the IVPD. Segmental IVPD was divided into mid to apex and base. Pearson's correlation coefficient was used to evaluate this relationship. RESULTS: There was a significant, positive relationship between IVPD and gestational age in both ventricles (right ventricle [RV]: r = 0.800, left ventricle [LV]: r = 0.818). As for segmental IVPD, basal and mid-apical IVPD also increased with gestation in both ventricles (RV: basal, r = 0.627; mid-apical, r = 0.705; LV: basal r = 0.758; mid-apical, r = 0.756). IVPG, which was calculated as IVPD/ventricular length, also showed a weak, positive relationship with gestation in both ventricles (RV r = 0.351, p < 0.001; LV r = 0.373, p < 0.001). CONCLUSION: The total and segmental IVPDs significantly increased linearly through time.


Asunto(s)
Ecocardiografía Doppler en Color , Ventrículos Cardíacos , Humanos , Femenino , Embarazo , Presión Ventricular , Ventrículos Cardíacos/diagnóstico por imagen , Ecocardiografía Doppler en Color/métodos , Feto , Ecocardiografía
3.
J Clin Ultrasound ; 51(6): 963-971, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37000708

RESUMEN

PURPOSE: For assessing the severity of tricuspid regurgitation (TR), there is no gold standard. We developed a parameter, the right ventricular systolic force ratio-RIVIERA, using the continious wave Doppler analysis of TR and pulsed-wave analysis of the right ventricle outflow tract. We hypothesized that the RIVIERA would facilitate the ability to identify severe TR in clinical settings. MATERIALS AND METHODS: We obtained data from routine transthoracic echocardiograms. All records reporting no or mild TR (n = 732), moderate TR (n = 584), and severe TR (n = 519) TR were reanalyzed to measure vena contracta (VC) width, TR jet area, effective regurgitant orifice (EROA) derived with the proximal isovelocity surface area method, the RIVIERA, and right-sided chamber volumes. RESULTS: Significant linear trends were demonstrated for right atrial volume index, end-diastolic volume index, RVOT velocity time integral, TR jet area, TR-Vmax, TR-VTI, TR acceleration, VC width, EROA with increasing TR severity. Independent predictors of severe RT included RIVIERA <4.8, VC width ≥0.7 cm, TR jet area > 10 cm2 , and EROA ≥0.4 cm2 . CONCLUSION: The RIVIERA is a feasible, effective, and independent predictor of severe TR that enhances established techniques for estimating TR severity. For clinical decision-making and management, accurate measurement and classification of TR severity are essential. Therefore, it should be thought about include the RIVIERA in the integrative method to assessing TR severity.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Ventrículos Cardíacos , Ecocardiografía Doppler en Color/métodos , Ecocardiografía , Atrios Cardíacos , Índice de Severidad de la Enfermedad
4.
J Cardiothorac Vasc Anesth ; 36(9): 3501-3508, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35595583

RESUMEN

OBJECTIVES: The primary aim of this study was to assess interobserver variability in grading tricuspid regurgitation (TR) severity. The authors' secondary goals were to delineate which transesophageal echocardiographic (TEE) parameters best correlate with severity and how consistent the participants were at grading severity. DESIGN: This was a prospective cohort study of how clinicians evaluated previously acquired TEE images and videos. SETTING: The 19 TEE studies of patients with TR were recorded by 4 senior echocardiographers across 4 US academic institutions. The participants evaluated these cases on a novel, web-based, assessment environment designed specifically for this study. PARTICIPANTS: Twenty-nine fellowship-trained and board-certified cardiologists and cardiothoracic anesthesiologists volunteered to participate in the study as observers from 19 different institutions. INTERVENTIONS: No interventions were performed on the participants. MEASUREMENTS AND MAIN RESULTS: For each case, participants measured the vena contracta (VC), proximal isovelocity surface area (PISA), and jet area before giving a final classification on the severity of TR. Variation was highest for effective regurgitant orifice area and lowest for VC and PISA. The coefficient of variation, defined as the standard deviation from the mean divided by the mean, for all cases of trace, mild, moderate and severe TR were as follows: Jet Area-111%, 46%, 48%, 76%; VC-67%, 44%, 43%, 36%; PISA-52%, 48%, 31%, 35%; and effective regurgitant orifice area-127%, 95%, 66%, 58%. CONCLUSIONS: The interobserver variation in quantifying TEE parameters for TR is high, suggesting these may be difficult to measure reliably in a busy perioperative setting. Of the parameters assessed, VC and PISA radius had the highest interobserver agreement and the highest correlation with severity.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Ecocardiografía , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Tridimensional/métodos , Humanos , Internet , Variaciones Dependientes del Observador , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen
5.
J Cardiothorac Vasc Anesth ; 36(4): 974-982, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34799263

RESUMEN

OBJECTIVES: To evaluate the effect of general anesthesia (GA) on severity of mitral regurgitation (MR) in patients undergoing transcatheter mitral valve repair (TMVR). DESIGN: Retrospective cohort study. SETTING: Tertiary care university hospital. PARTICIPANTS: Fifty consecutive patients with symptomatic severe MR and extremely high surgical risk. INTERVENTION: TMVR under GA. MEASUREMENTS AND RESULTS: Transesophageal echocardiography was performed during the preprocedural workup under conscious sedation and during TMVR under GA. After the parameters of MR were assessed, color-flow jet area (CJA), vena contracta (VC), effective regurgitant orifice area (EROA), regurgitant volume (RVOL), three-dimensional (3D) vena contracta area (VCA), and severity of MR were compared between the two examinations. In patients with primary MR (n = 11), there were no significant differences in CJA, VC, EROA, RVOL, or 3D-VCA between pre- and intraprocedural transesophageal echocardiography. In patients with secondary MR (n = 39), GA led to significant decreases of CJA (10 ± 7 v 7 ± 3 cm², p < 0.001), VC (5.5 ± 1.6 v 4.7 ± 1.5 mm, p = 0.002), EROA (30 ± 11 v 24 ± 10 mm², p < 0.001), and RVOL (47 ± 17 v 34 ± 13 mL/beat, p < 0.001). Consequently, GA led to a downgrade of regurgitation severity classification in 44% of patients when assessed by two-dimensional analysis. When evaluated by 3D analysis, GA also led to a significant but less extensive decrease of MR (3D-VCA: 66 ± 27 v 60 ± 29 mm², p = 0.002), and subsequent downgrade of MR classification in 20% of patients. CONCLUSIONS: GA underestimates regurgitation severity in patients with secondary, but not primary MR, undergoing TMVR. This effect must be considered when evaluating the immediate result of the procedure.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Anestesia General , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Tridimensional/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
6.
Pediatr Res ; 89(4): 987-995, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32570271

RESUMEN

BACKGROUND: We implemented sophisticated color M-mode analysis to assess age-dependent progression of left ventricular (LV) diastolic function. METHODS: Normal infants were prospectively enrolled for serial echocardiograms at 1 week, 1 month, 6 months, 1 year, and 2 years. From color M-mode scans, propagation velocity (VP), strength of filling (VS), and intraventricular pressure difference (IVPD) in 3 segments along apex-to-mitral valve scan line were measured. RESULTS: Age-wise comparisons of diastolic filling from 121 echocardiograms in 31 infants showed VP (cm/s), VS (cm2/s), and E-wave IVPD (mmHg) at 1 week to be 66.2 ± 11.9, 75.3 ± 19.9, and 1.5 ± 0.4, respectively, while VP, VS, and E-wave IVPD at 1 month were 80.3 ± 14.4, 101.2 ± 28.3, and 2.42 ± 1.1, respectively. There were significant differences in VP and segmental IVPD between first week and first month (p < 0.005) and IVPD between the age groups (p < 0.001). CONCLUSIONS: Comprehensive analysis of transmitral color M-mode data is feasible in infants, enabling calculation of pressure drop between the LV base and apex and strength of propagation from two distinct slopes. Profound changes very early followed by relatively constant filling mechanics in later infancy indicate significant LV maturation occurring during the first month of life. IMPACT: We implemented sophisticated analytic methods for color M-mode echocardiography in infants to assess age- and dimension-dependent changes in left ventricular diastolic function. Comprehensive characterization of transmitral color M-mode flow was feasible, enabling calculation of pressure drop between left ventricular base and apex and strength of propagation. Left ventricular diastolic filling function has predictable maturational progression, with significant differences in the intraventricular pressure between infants from birth to 2 years. This study forms the basis for future studies to examine alteration of early diastolic filling in congenital heart disease.


Asunto(s)
Corazón/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Preescolar , Diástole , Progresión de la Enfermedad , Ecocardiografía , Ecocardiografía Doppler en Color/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda , Presión Ventricular
7.
J Interv Cardiol ; 2020: 7136802, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32140088

RESUMEN

PURPOSE: The Occlutech Figulla occluder has been proven safe and effective at midterm follow-up after percutaneous atrial septal defect (ASD) closure. We describe the safety and efficacy at long-term follow-up in adults. METHODS: All consecutive adult patients that underwent ASD closure between 2008 and 2015 were included. All complications were registered. Residual left-to-right shunt (LRS) was diagnosed using color-Doppler transthoracic echocardiography (TTE). Right-to-left shunting was diagnosed using contrast TTE. Successful closure was defined as no LRS at follow-up. RESULTS: In total, 166 patients (mean age 56.7 ± 16.1 years; 62% female) underwent percutaneous ASD closure using the Occlutech Flex I (70%) or Flex II (30%) device (diameter 24 mm; range 10-40 mm) under general anaesthesia and transoesophageal echocardiographic guidance. Long-term follow-up data were available for 144 patients (87%) with a mean follow-up of 5.9 ± 2.6 years, a total of 814 patient-years. During hospitalization, device embolization occurred in three patients (1.8%) with successful extraction in all. During the long-term follow-up, 15 patients (9.8%) suffered new-onset atrial fibrillation and stroke occurred in 2.1%. There was no residual LRS at 12-month follow-up. No device embolization occurred during the long-term follow-up. CONCLUSION: Percutaneous ASD closure using the Occlutech device appears to be safe at long-term follow-up with a high successful closure rate at one year.


Asunto(s)
Complicaciones Posoperatorias , Dispositivo Oclusor Septal , Cateterismo Cardíaco/métodos , Ecocardiografía Doppler en Color/métodos , Femenino , Estudios de Seguimiento , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/cirugía , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Dispositivo Oclusor Septal/efectos adversos , Dispositivo Oclusor Septal/estadística & datos numéricos
8.
Cardiology ; 145(2): 80-87, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31825945

RESUMEN

BACKGROUND: Diabetes mellitus type 1 (DM1) is associated with a high risk for cardiovascular disease, and early detection of myocardial dysfunction is crucial for the prevention of cardiac complications. OBJECTIVES: The aim of this study was to evaluate left ventricular (LV) and right ventricular (RV) function by using both conventional echocardiography as well as multi-layered speckle tracking echocardiography (STE) in young adults with DM1. METHODS: We included 50 young asymptomatic adults diagnosed with DM1 (mean interval from diagnosis 9 ± 6 years) and 80 healthy controls. STE was acquired using the GE Vivid S60 equipment. The LV longitudinal strain (LS), layer-specific strains of the endocardium, myocardium, and epicardium (global longitudinal strain [GLS]endo, GLSmyo, GLSepi) as well as RV strain were obtained using the EchoPAC BT13 workstation. RESULTS: No significant intergroup differences in LV ejection fraction were noted. GLSendo and GLSmyo were reduced in the DM1 group (-20.6 ± 2.7 vs. -22.0 ± 2.3 and -18.0 ± 2.4 vs. -19.1 ± 1.9, respectively, p < 0.05) compared to controls. Mechanical dispersion was higher in the diabetes group (34 ± 11 vs. 29 ± 7, p < 0.05). RV strain measurements showed no significant difference between the groups. CONCLUSIONS: Young adults with DM1 and without known heart disease have subclinical myocardial dysfunction with lower LV endocardium and myocardium LS and higher mechanical dispersion demonstrated by multi-layered STE.


Asunto(s)
Diabetes Mellitus Tipo 1/complicaciones , Cardiomiopatías Diabéticas/diagnóstico , Ecocardiografía Doppler en Color/métodos , Ventrículos Cardíacos/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico , Adulto , Estudios de Casos y Controles , Cardiomiopatías Diabéticas/complicaciones , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Estudios Prospectivos , Rumanía , Disfunción Ventricular Izquierda/etiología , Función Ventricular Derecha , Adulto Joven
9.
Fetal Diagn Ther ; 47(4): 268-276, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31597155

RESUMEN

BACKGROUND: In the first trimester, ultrasound confirmation of normal or abnormal cardiac anatomy is difficult. B-mode and colour flow Doppler (CFD) are used to assess the foetal heart. Superb microvascular imaging (SMI) can visualise blood flow within the heart and vessels in early gestation. OBJECTIVE: We report an initial experience of SMI for visualisation of normal and abnormal cardiac anatomy in the first trimester. METHODS: Transabdominal foetal echocardiography was performed between 11 + 6 and 14 + 3 weeks (Aplio 500 US system, Toshiba Medical Systems, Tokyo, Japan) from January 2017 to December 2017. All scans were performed at a tertiary foetal cardiology unit. To assess the potential utility of the technique for early gestation screening, normal scans were reviewed by foetal medicine trainees with respect to the B-mode, CFD and SMI. Three key views were selected to compare modalities: the 4-chamber view, outflow tracts and the 3-vessel and trachea view (VTV). Visualisation rates of key echocardiographic features of significant cardiac abnormalities by SMI were reviewed. RESULTS: Fifty-five normal echocardiograms and 34 cardiac abnormalities were included. In the normal heart, when B-mode, CFD and SMI were assessed separately, SMI had the highest rate of visualisation of 4-chamber, outflow tracts and 3-VTV (93, 85 and 83%, respectively). Intra-observer reliability was moderate for SMI of the 3 standard views (kappa 1, 0.64 and 0.64); inter-observer for 4-chamber and outflow tract views was moderate (kappa 0.64 and 0.77). In 29/34 abnormal cases, SMI showed key features, enhancing greyscale visualisation. CONCLUSION: SMI has potential to become a useful, complementary modality for early foetal echocardiography. Further prospective studies are warranted to establish the place of the technique in assessment of the first trimester foetal heart.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Femenino , Humanos , Embarazo , Primer Trimestre del Embarazo , Estudios Prospectivos
10.
Heart Lung Circ ; 29(6): 914-920, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31402125

RESUMEN

BACKGROUND: Multiple atrial septal defects (ASD) with an inferior sinus venosus defect (SVD) have always been considered to be contraindications for interventional therapy. On the basis of early experience using a patent ductus arteriosus (PDA) occluder for interventional treatment for inferior ASD, this study investigated the feasibility of transcatheter closure of multiple ASDs with an inferior SVD under the guidance of three-dimensional (3D) printed heart models. METHODS: Between August 2016 and February 2017, five patients who were diagnosed with multiple ASDs with an inferior SVD at the First Affiliated Hospital of Xi'an Jiaotong University underwent cardiac computed tomography (CT) scans and three-dimensional (3D) echocardiography to generate heart disease models by a 3D printing technique. The best occlusion program was determined through a simulated closure on the model. Percutaneous device closure of multiple ASDs with an inferior SVD was performed following the predetermined program, guided only by fluoroscopy. Follow-up included electrocardiography, transthoracic echocardiography, and transoesophageal echocardiography. RESULTS: Three-dimensional (3D) printed models for all five patients were produced successfully. Four (4) patients had a secundum ASD with an inferior sinus venosus ASD, and one patient had a patent foramen ovale (PFO) with an inferior sinus venosus ASD. All patients were successfully treated with interventional therapy. Inferior sinus venosus ASD was percutaneously closed using the PDA occluder, and the additional secundum ASD or PFO in each patient was percutaneously closed using an ASD or PFO occluder at the same time. There was no device embolisation, procedure-related death or pericardial tamponade. During the 1-year follow-up, a minor residual shunt was detected in one patient. CONCLUSION: The use of 3D printed ASD models provides a useful reference for transcatheter device closure of multiple ASD with an inferior SVD. This approach can provide a new treatment strategy for inferior sinus venosus ASD, which has been considered a contraindication for interventional therapy. However, long-term follow-up in a large number of patients is still warranted.


Asunto(s)
Cateterismo Cardíaco/métodos , Defectos del Tabique Interatrial/cirugía , Impresión Tridimensional , Dispositivo Oclusor Septal , Adulto , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Transesofágica/métodos , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Defectos del Tabique Interatrial/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
11.
Heart Vessels ; 34(2): 296-306, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30155660

RESUMEN

Although the suction force that moves blood into the left ventricle during early diastole is thought to play an important role in diastolic function, there have been a few studies of this phenomenon in normal children. Suction force is measured as the intraventricular pressure difference (IVPD) and intraventricular pressure gradient (IVPG), which is calculated as IVPD divided by left ventricular length. The purpose of this study was to determine the suction force in infants, children, and adolescents using IVPD and IVPG. We included 120 normal children categorized into five groups based on age: G1 (0-2 years), G2 (3-5 years), G3 (6-8 years), G4 (9-11 years), and G5 (12-16 years). The total, basal, and mid-apical IVPD and IVPG were calculated using color M-mode Doppler imaging of the mitral valve inflow using the Euler equation. The total IVPD increased with age from G1 to G5 (1.75 + 0.51 vs. 2.95 + 0.72 mmHg, respectively; p < 0.001), due to an increase in mid-apical IVPD with constant basal IVPD. Although total IVPG was constant, mid-apical IVPG was larger in G5 than in G1 (0.21 + 0.06 vs. 0.16 + 0.07 mmHg/cm, respectively; p = 0.006). Total, basal, and mid-apical IVPDs were significantly correlated with age and the parameters of heart size and mitral annular e'. Mid-apical IVPG correlated with age and e' positively, but basal IVPG did with age negatively and did not with e'. The suction force increased at the mid-apical segment, correlating with increasing heart size and developing left ventricular relaxation, even after adjustment for left ventricular length.


Asunto(s)
Función del Atrio Izquierdo/fisiología , Ecocardiografía Doppler en Color/métodos , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Presión Ventricular/fisiología , Adolescente , Niño , Preescolar , Diástole , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Valores de Referencia
12.
Cardiovasc Ultrasound ; 17(1): 4, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30823923

RESUMEN

BACKGROUND: Professor Xinfang Wang first introduced the clinical application of trans nose pharynx esophagus echocardiography (TNPEE) in 2014. Subsequently, we developed the technology. In the present study we assess the feasibility of TNPEE in the ultrasonic diagnosis. METHODS: Select patients suitable for TNPEE examination. After obtaining written consent of patients or their families, oral dacronin hydrochloride gel local anesthesia was given 10-15 min before examination. The nostrils were disinfected and then smeared with tetracaine hydrochloride gel, which acted as local anesthesia and lubrication. The probe was inserted gently through the nostrils and entered the esophagus through the nasal cavity and pharynx. TNPEE is similar to transoral esophagus echocardiography (TOEE) after the probe reaches the esophagus. RESULTS: TNPEE was performed in 103 patients. Forty-five patients (43.7%) underwent the examination successfully, 46 patients (44.7%) failed because of objective reasons, 12 patients midway refused to accept the examination and cancelled the examination, accounting for 11.6%, 11 patients (12.1%) suffered from epistaxis. Of all the patients with epistaxis, 9 had taken anticoagulant drugs, accounting for 82% of the patients with epistaxis. The vital signs of all patients were stable and no serious complications occurred. CONCLUSION: Compared with TOEE, TNPEE can cause less nausea and vomiting reaction, and patients take longer time to undergo examination, which is conducive to more detailed examination. However, TNPEE has a high requirement for the probe, and its success rate is relatively low. It is easy to cause nasal bleeding in patients, so its wide clinical application is limited.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Ecocardiografía Transesofágica/métodos , Cardiopatías/diagnóstico , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nariz , Faringe , Reproducibilidad de los Resultados , Estudios Retrospectivos
13.
Cardiovasc Ultrasound ; 17(1): 5, 2019 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-30944001

RESUMEN

BACKGROUND: Three-dimensional color flow Doppler (3DCF) is a new convenient technique for cardiac output (CO) measurement. However, to date, no one has evaluated the accuracy of 3DCF echocardiography for CO measurement after cardiac surgery. Therefore, this single-center, prospective study was designed to evaluate the reliability of three-dimensional color flow and two-dimensional pulse wave Doppler (2D-PWD) transthoracic echocardiography for estimating cardiac output after cardiac surgery. METHODS: Post-cardiac surgical patients with a good acoustic window and a low dose or no dose of vasoactive drugs (norepinephrine < 0.05 µg/kg/min) were enrolled for CO estimation. Three different methods (third generation FloTrac/Vigileo™ [FT/V] system as the reference method, 3DCF, and 2D-PWD) were used to estimate CO before and after interventions (baseline, after volume expansion, and after a dobutamine test). RESULTS: A total of 20 patients were enrolled in this study, and 59 pairs of CO measurements were collected (one pair was not included because of increasing drainage after the dobutamine test). Pearson's coefficients were 0.260 between the CO-FT/V and CO-PWD measurements and 0.729 between the CO-FT/V and CO-3DCF measurements. Bland-Altman analysis showed the bias between the absolute values of CO-FT/V and CO-PWD measurements was - 0.6 L/min with limits of agreement between - 3.3 L/min and 2.2 L/min, with a percentage error (PE) of 61.3%. The bias between CO-FT/V and CO-3DCF was - 0.14 L/min with limits of agreement between - 1.42 L /min and 1.14 L/min, with a PE of 29.9%. Four-quadrant plot analysis showed the concordance rate between ΔCO-PWD and ΔCO-3FT/V was 93.3%. CONCLUSIONS: In a comparison with the FT/V system, 3DCF transthoracic echocardiography could accurately estimate CO in post-cardiac surgical patients, and the two methods could be considered interchangeable. Although 2D-PWD echocardiography was not as accurate as the 3D technique, its ability to track directional changes was reliable.


Asunto(s)
Gasto Cardíaco/fisiología , Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Doppler en Color/métodos , Ecocardiografía Tridimensional/métodos , Cardiopatías/diagnóstico , Ventrículos Cardíacos/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Cardiopatías/fisiopatología , Cardiopatías/cirugía , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
14.
Cardiovasc Ultrasound ; 17(1): 14, 2019 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-31325956

RESUMEN

BACKGROUND: Postnatal outcome of fetuses with isolated single umbilical artery (SUA) is determined mainly by right ventricular function. Our study examined whether there are differences in right ventricular function during the gestation period of fetuses with isolated SUA compared to healthy fetuses. METHODS: A prospective study was conducted on 77 fetuses with isolated SUA and 77 gestational age-matched controls from 22 to 39 weeks. For gestational age grouping, the isolated SUA fetuses and the control fetuses were divided into the second trimester group (22-27 weeks; 43 fetuses) and third trimester group (28-39 weeks; 34 fetuses). The fetal tricuspid annular plane systolic excursion (f-TAPSE) M-mode was applied to the tricuspid annulus, parallel to the ventricular septum, and the amplitude of the resulting wave was assessed using spatiotemporal image correlation (STIC) M-mode. We investigated the possible changes to the STIC M-mode indices during the course of pregnancy in both the isolated SUA and control groups. The relationship between f-TAPSE and gestational age was analyzed. Additionally, the correlations between f-TAPSE and birth weight was analyzed, and the birth weight differences between the isolated SUA and control groups in the third trimester were analyzed according to postpartum results. RESULTS: There was a significant difference in f-TAPSE between isolated SUA and control group in the third trimester (P < 0.05). There were significant correlations between gestational age (GA) and f-TAPSE among control fetuses (R2 = 0.9049; P < 0.01). A significant, positive correlation between GA and f-TAPSE was also found with isolated SUA fetuses (R2 = 0.8108; P < 0.01). The prevalence of small-for-gestational-age (SGA) fetuses and of discordant birth weight fetuses was significantly higher in the isolated SUA group than in the control group. In univariate analysis, the presence of an isolated SUA was associated with lower birth weight (2940 g compared with 3260 g) and with higher prevalence of SGA (13.0% compared with 3.9%; P < 0.01). The correlations between the birth weight and f-TAPSE in the two groups were analyzed in the third trimester, and the correlation in the isolated SUA group was better than that of the control group (R2 was 0.623 and 0.463 in the isolated SUA group and the control group, respectively). CONCLUSIONS: Right ventricular function in isolated SUA is altered as early as in fetal third trimester. STIC M-mode can measure the right heart function of the fetus and may predict isolated SUA with SGA.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Corazón Fetal/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Arteria Umbilical Única/diagnóstico , Ultrasonografía Prenatal/métodos , Arterias Umbilicales/diagnóstico por imagen , Función Ventricular Derecha/fisiología , Adulto , Femenino , Corazón Fetal/fisiopatología , Edad Gestacional , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/embriología , Humanos , Embarazo , Tercer Trimestre del Embarazo , Estudios Prospectivos , Reproducibilidad de los Resultados , Arteria Umbilical Única/fisiopatología , Arterias Umbilicales/anomalías , Arterias Umbilicales/embriología
15.
BMC Nephrol ; 20(1): 446, 2019 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-31796001

RESUMEN

BACKGROUND: To investigate predictive factors related to graft failure of IgA nephropathy(IgAN) in renal allografts following living donor transplantation. METHODS: We identified a series of 102 biopsies diagnosed as IgAN in renal allografts following living donor transplantation from July 2004 to January 2017 at our center, and assess the predict value of the Lee's classification and the 2009 Oxford classification in IgAN in renal allografts, clinical, ultrasonic and pathological characteristics at biopsy and the outcomes were retrospectively analyzed. RESULTS: The 5-year graft cumulative survival rate after transplantation was 91.4%. The 4-year graft cumulative survival rate after biopsy diagnosis of IgAN in renal allografts was 59.6%. The mean time ± SD to disease was 4.7 ± 3.5 years. The color doppler ultrasound and blood flow imagine showed the echo enhancement, the reduced blood flow distribution, the reduced peak systolic velocity of main renal artery, and the increased resistance index of arcuate renal artery were valuable in evaluating the graft dysfunction. The Cox multivariate analysis revealed that the 24-h urinary protein level (HR 1.6 for 1-g increase, 95%CI 1.2-2.0), estimated glomerular filtration rate (eGFR) (HR 1.0 for 1-mL/min/1.73 m^2 decline, 95%CI 1.0-1.1), and mesangial C1q deposition (HR 3.0, 95%CI 1.2-7.4) at biopsy were independent predictive factors of graft failure of IgAN in renal allografts. CONCLUSIONS: IgAN in renal allografts occurred frequently within 5 years after transplantation. The risk of graft failure should be taken seriously in patients who exhibit heavy proteinuria and/or a declined eGFR as the initial symptoms; a high lesion grade (grade IV-V of Lee's classification) and/or mesangial C1q deposition may also indicated a poor outcome.


Asunto(s)
Aloinjertos , Biopsia , Glomerulonefritis por IGA/diagnóstico , Fallo Renal Crónico/cirugía , Trasplante de Riñón , Riñón , Proteinuria , Adulto , Aloinjertos/diagnóstico por imagen , Aloinjertos/patología , Aloinjertos/fisiopatología , Biopsia/métodos , Biopsia/estadística & datos numéricos , Ecocardiografía Doppler en Color/métodos , Femenino , Tasa de Filtración Glomerular , Supervivencia de Injerto , Humanos , Riñón/diagnóstico por imagen , Riñón/patología , Riñón/fisiopatología , Trasplante de Riñón/efectos adversos , Trasplante de Riñón/métodos , Donadores Vivos , Masculino , Pronóstico , Proteinuria/diagnóstico , Proteinuria/etiología , Circulación Renal
16.
Echocardiography ; 36(5): 1017-1018, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31025758

RESUMEN

In the current manuscript, we report an unusual case of a young 18-year-old woman who survived an out-of-hospital cardiac arrest secondary to Bland-White-Garland syndrome. Her transthoracic echocardiogram showed an abnormal color Doppler flow-pattern within the myocardium indicative of coronary fistulous flow that prompted further evaluation with coronary CT angiography, which confirmed the diagnosis. Our case serves not only as a reminder to consider coronary artery anomalies as a cause of sudden cardiac death in young individuals but also as a prompt to investigate unusual echocardiographic findings with alternative imaging when the diagnosis may not be initially clear.


Asunto(s)
Síndrome de Bland White Garland/complicaciones , Síndrome de Bland White Garland/diagnóstico por imagen , Ecocardiografía Doppler en Color/métodos , Paro Cardíaco/etiología , Adolescente , Angiografía Coronaria/métodos , Diagnóstico Diferencial , Femenino , Corazón , Humanos
17.
Echocardiography ; 36(7): 1364-1371, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31169946

RESUMEN

BACKGROUND: A vortex is a rotational fluid structure formed by shearing of fluid layers. It forms during diastole in the left ventricle (LV) and helps redirect flow to the LV outflow tract for ejection, optimizing energy conservation. The aim of this study was to demonstrate the feasibility of detecting and analyzing LV vortices using a new ultrasound technique known as blood speckle imaging (BSI). METHODS: Conventional and BSI parameters were acquired in preterm infants referred for echocardiography. BSI feasibility and reliability were explored using highest frequency settings and optimized Nyquist limits. Vortex area was determined by tracing the outer vortex ring at maximum area. Peak vortex formation time (PVFT) was determined at time of maximum vortex area relative to the R-wave, and vortex duration from frame-by-frame analysis of first appearance to vortex degradation. RESULTS: Left ventricle vortices were detected in 49 of the 50 preterm infants (weight 500-2020 g) with excellent intra- and inter-observer reliability. Mean vortex area indexed to LV area was 0.19 (0.08). Peak vortex formation time was at 87 (7)% of the cardiac cycle, and vortex duration lasted 13 (4)% of the cardiac cycle. Vortex area correlated positively with LV length, end-diastolic dimension, end-diastolic volume, mitral annular (R +0.42, +0.50, +0.47, +0.50, all P < 0.01), and transmitral Vti (R +0.37, P < 0.01). PVFT correlated negatively with E, EA, and Ee' (R -0.42, -0.47, -0.47, all P < 0.01). CONCLUSION: Left ventricle vortex formation can be analyzed with two-dimensional BSI and has the potential to complement existing parameters of cardiac health.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Función Ventricular Izquierda/fisiología , Velocidad del Flujo Sanguíneo , Estudios Transversales , Diástole , Estudios de Factibilidad , Femenino , Humanos , Recién Nacido , Recien Nacido Prematuro , Masculino , Reproducibilidad de los Resultados
18.
Echocardiography ; 36(7): 1315-1321, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31246345

RESUMEN

OBJECTIVES: Recently, three-dimensional proximal isovelocity surface area (3D PISA) method has already been widely used in tricuspid regurgitation assessment. This study attempts to demonstrate the feasibility and accuracy of 3D PISA quantifying tricuspid regurgitation and explore the clinical value of 3D PISA in quantifying tricuspid regurgitation. METHODS: Fifty-four patients with more than mild tricuspid regurgitation (TR) were enrolled. Effective regurgitant orifice area (EROA) and regurgitant volume (Rvol) were assessed by transthoracic 3D PISA method and three-dimensional vena contracta area (3D VCA) method. The 3D VCA was used as reference method. We analyzed the correlation and differences of EROA between 3D PISA method and the reference method. RESULTS: Both EROA and Rvol assessed by the 3D PISA had good correlations with the reference method, particularly in the assessment of eccentric jets, with the correlation coefficients of r (EROA) = 0.83, P < 0.001, r (Rvol) = 0.90, P < 0.001, respectively. 3D PISA method had good agreement with 3D VCA method in grading TR. Intra-observer and inter-observer agreement were also good. CONCLUSIONS: Three-dimensional proximal isovelocity surface area method can accurately quantify the degree of tricuspid regurgitation with good repeatability and shorter time-consuming, which is worthy of further study. 3D PISA method is expected to be a new method for evaluating tricuspid regurgitation in clinic practice.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Ecocardiografía Tridimensional/métodos , Interpretación de Imagen Asistida por Computador/métodos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad
19.
Echocardiography ; 36(5): 1009-1013, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31002180

RESUMEN

Coronary artery fistula (CAF) is a rare malformation and is seldom reported during pregnancy. Right coronary artery fistula commonly drains into the right ventricle, right atrium, or pulmonary artery. We describe here a rare case of fetal CAF draining into the left ventricle using cross-sectional and color Doppler echocardiography. We also summarized our experience in the diagnosis of this uncommon malformation, in which tracing the origin, course, and outlet of the abnormal intra-cardiac flow played a key role.


Asunto(s)
Anomalías de los Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler en Color/métodos , Fístula/diagnóstico por imagen , Fístula/embriología , Ultrasonografía Prenatal/métodos , Adulto , Femenino , Corazón Fetal/anomalías , Corazón Fetal/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Recién Nacido , Masculino , Embarazo
20.
Echocardiography ; 36(11): 2118-2121, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31693216

RESUMEN

Noncompaction of the ventricular myocardium (NVM), also known as spongy myocardium, is a rare type of cardiomyopathy that has a serious impact on fetuses, children, and adults. NVM mainly affects the left ventricle, as isolated right ventricular noncompaction (IRVNC) is rare. Pulmonary artery sling (PAS) is a rare condition in which the left pulmonary artery anomalously originates from a normal positioned right pulmonary artery, and only a few studies have reported PAS in fetuses. Fetal IRVNC complicated with PAS has not been reported yet. Here, we report a case of IRVNC complicated with PAS that was diagnosed prenatally at 30 weeks gestation and confirmed by postpartum anatomy and pathology.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Corazón Fetal/diagnóstico por imagen , Ventrículos Cardíacos/anomalías , No Compactación Aislada del Miocardio Ventricular/diagnóstico , Arteria Pulmonar/anomalías , Ultrasonografía Prenatal/métodos , Malformaciones Vasculares/diagnóstico , Adulto , Resultado Fatal , Femenino , Edad Gestacional , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/embriología , Humanos , Recién Nacido , No Compactación Aislada del Miocardio Ventricular/embriología , Embarazo , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/embriología , Enfermedades Raras , Malformaciones Vasculares/embriología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA