Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Analyst ; 145(8): 3056-3063, 2020 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-32141454

RESUMEN

Hydrogen/deuterium exchange coupled to mass spectrometry (HDX-MS) is a well-established technique for structural analysis of proteins. In HDX experiments it is common to label for multiple, different lengths of time to characterize protein structures and dynamics. However, applications of HDX to carbohydrates have been limited due to the rapid exchange rates of hydroxyls, which have also prevented the development and application of methods that sample HDX at multiple timepoints. Theta capillaries pulled to electrospray tips have been used to achieve microsecond reaction times. Here, we report the utilization of theta-ESI emitters to achieve multiple timepoints for deuteration of carbohydrates. We increased the labeling time for HDX by increasing the initial ESI droplet sizes using theta-ESI emitters with increasing tip opening sizes. The reaction times achieved by varying the tip sizes ranged from sub-microsecond to ∼20 µs, with the average number of deuterium exchanges varying from 0.5 ± 0.2 D to 5 ± 3 D for sodium-adducted melezitose, which contains 11 labile hydrogens. Our findings are significant because this is the first report of carbohydrates analyzed by solution-phase HDX to achieve multiple H/D exchange timepoints.


Asunto(s)
Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/instrumentación , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Trisacáridos/química , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/métodos , Estructura Molecular , Espectrometría de Masa por Ionización de Electrospray/métodos
2.
Anal Chem ; 91(10): 6624-6631, 2019 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-31008583

RESUMEN

Taken individually, chemical labeling and mass spectrometry are two well-established tools for the structural characterization of biomolecular complexes. A way to combine their respective advantages is to perform gas-phase ion-molecule reactions (IMRs) inside the mass spectrometer. This is, however, not so well developed because of the limited range of usable chemicals and the lack of commercially available IMR devices. Here, we modified a traveling wave ion mobility mass spectrometer to enable IMRs in the trapping region of the instrument. Only one minor hardware modification is needed to allow vapors of a variety of liquid reagents to be leaked into the trap traveling wave ion guide of the instrument. A diverse set of IMRs can then readily be performed without any loss in instrument performance. We demonstrate the advantages of implementing IMR capabilities in general, and to this quadrupole-ion mobility-time-of-flight (Q-IM-TOF) mass spectrometer in particular, by exploiting the full functionality of the instrument, including mass selection, ion mobility separation, and post-mobility fragmentation. The potential to carry out gas-phase IMR kinetics experiments is also illustrated. We demonstrate the versatility of the setup using gas-phase IMRs of established utility for biological mass spectrometry, including hydrogen-deuterium exchange, ion-molecule proton transfer reactions, and covalent modification of DNA anions using trimethylsilyl chloride.


Asunto(s)
Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/métodos , Espectrometría de Movilidad Iónica/métodos , Marcaje Isotópico/métodos , Deuterio/química , Encefalina Leucina/análisis , Encefalina Leucina/química , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/instrumentación , Espectrometría de Movilidad Iónica/instrumentación , Marcaje Isotópico/instrumentación , Cinética , Protones , Ubiquitina/análisis , Ubiquitina/química
3.
Methods Mol Biol ; 2127: 339-358, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32112332

RESUMEN

Integral membrane proteins are involved in numerous biological functions and represent important drug targets. Despite their abundance in the human proteome, the number of integral membrane protein structures is largely underrepresented in the Protein Data Bank. The challenges associated with the biophysical characterization of such biological systems are well known. Most structural approaches, including X-ray crystallography, SAXS, or mass spectrometry (MS), require the complete solubilization of membrane proteins in aqueous solutions. Detergents are frequently used for this task, but may interfere with the analysis, as is the case with MS. The use of "MS-friendly" detergents, such as non-ionic alkyl glycoside detergents, has greatly facilitated the analysis of detergent-solubilized membrane proteins. Here, we describe a protocol, which we have successfully implemented in our laboratory to study the structure and dynamics of detergent-solubilized integral membrane proteins by Hydrogen/Deuterium eXchange and Mass Spectrometry (HDX-MS). The procedure does not require detergent removal prior to MS analysis, instead taking advantage of the ultra-high pressure chromatographic system to separate deuterated peptides from "MS-friendly" detergents.


Asunto(s)
Medición de Intercambio de Deuterio/métodos , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/métodos , Proteínas de la Membrana/química , Cristalografía por Rayos X , Detergentes/química , Deuterio/química , Medición de Intercambio de Deuterio/instrumentación , Humanos , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/instrumentación , Espectrometría de Masas , Proteínas de la Membrana/efectos de los fármacos , Modelos Moleculares , Conformación Proteica , Dispersión del Ángulo Pequeño , Solubilidad , Difracción de Rayos X
4.
J Am Soc Mass Spectrom ; 30(12): 2580-2583, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31724102

RESUMEN

Hydrogen/deuterium exchange mass spectrometry (HDX-MS) is a biophysical technique well suited to the characterization of protein dynamics and protein-ligand interactions. In order to accurately define the rate of exchange, HDX experiments require the repeated measure of deuterium incorporation into the target protein across a range of time points. Accordingly, the HDX-MS experiment is well suited to automation, and a number of automated systems for HDX-MS have been developed. The most widely utilized platforms all operate an integrated design, where robotic liquid handling is interfaced directly with a mass spectrometer. With integrated designs, the exchange samples are prepared and injected into the LC-MS following a "real-time" serial workflow. Here we describe a new HDX-MS platform that is comprised of two complementary pieces of automation that disconnect the sample preparation from the LC-MS analysis. For preparation, a plate-based automation system is used to prepare samples in parallel, followed by immediate freezing and storage. A second piece of automation has been constructed to perform the thawing and LC-MS analysis of frozen samples in a serial mode and has been optimized to maximize the duty cycle of the mass spectrometer. The decoupled configuration described here reduces experiment time, significantly improves capacity, and improves the flexibility of the platform when compared with a fully integrated system.


Asunto(s)
Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/métodos , Descubrimiento de Drogas/economía , Descubrimiento de Drogas/instrumentación , Descubrimiento de Drogas/métodos , Diseño de Equipo , Análisis de Inyección de Flujo/economía , Análisis de Inyección de Flujo/instrumentación , Análisis de Inyección de Flujo/métodos , Humanos , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/economía , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/instrumentación , Ligandos , Proteínas/química
5.
Drug Test Anal ; 11(8): 1207-1217, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31041833

RESUMEN

The ongoing shift from small molecule drugs to protein therapeutics in the pharmaceuticals industry presents a considerable challenge to generic drug developers who are increasingly required to demonstrate biosimilarity for biological macromolecules, a task that is decidedly more complex than doing the same for small molecule drugs. In this work, we demonstrate a multipronged mass-spectrometry-based workflow that allows rapid and facile molecular characterization of antibody-based protein therapeutics, applied to biosimilars development. Specifically, we use a combination of native mass spectrometry (MS), ion mobility spectrometry (IMS), and global time-resolved hydrogen deuterium exchange (HDX) to provide an unambiguous assessment of the structural, dynamic, and chemical similarity between Avastin (bevacizumab) and a biosimilar in the late stages of pre-clinical development. Minor structural and dynamic differences between the biosimilar and Avastin, and between lots of the biosimilar, were tested for functional relevance using Surface Plasmon Resonance-derived kinetic and equilibrium binding parameters.


Asunto(s)
Antineoplásicos Inmunológicos/química , Bevacizumab/química , Biosimilares Farmacéuticos/química , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Antineoplásicos Inmunológicos/farmacología , Bevacizumab/farmacología , Biosimilares Farmacéuticos/farmacología , Diseño de Equipo , Humanos , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/economía , Espectrometría de Masas de Intercambio de Hidrógeno-Deuterio/instrumentación , Espectrometría de Movilidad Iónica/economía , Espectrometría de Movilidad Iónica/instrumentación , Espectrometría de Movilidad Iónica/métodos , Espectrometría de Masa por Ionización de Electrospray/economía , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Factores de Tiempo , Factor A de Crecimiento Endotelial Vascular/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA