Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.816
Filtrar
Más filtros

Colección Odontología Uruguay
Intervalo de año de publicación
1.
Lancet ; 402(10409): 1251-1260, 2023 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-37805216

RESUMEN

BACKGROUND: Multicancer early detection (MCED) blood tests can detect a cancer signal from circulating cell-free DNA (cfDNA). PATHFINDER was a prospective cohort study investigating the feasibility of MCED testing for cancer screening. METHODS: In this prospective cohort study done in oncology and primary care outpatient clinics at seven US health networks, a convenience sample of adults aged 50 years or older without signs or symptoms of cancer consented to MCED testing. We collected blood, analysed cfDNA, and returned results to participants' doctors. If a methylation signature indicative of cancer was detected, predicted cancer signal origin(s) informed diagnostic assessment. The primary outcome was time to, and extent of, diagnostic testing required to confirm the presence or absence of cancer. This trial is registered at ClinicalTrials.gov, NCT04241796, and is completed. FINDINGS: Between Dec 12, 2019, and Dec 4, 2020, we recruited 6662 participants. 4204 (63·5%) of 6621 participants with analysable results were women, 2417 (36·5%) were men, and 6071 (91·7%) were White. A cancer signal was detected in 92 (1·4%) of 6621 participants with analysable results. 35 (38%) participants were diagnosed with cancer (true positives) and 57 (62%) had no cancer diagnosis (false positives). Excluding two participants whose diagnostic assessments began before MCED test results were reported, median time to diagnostic resolution was 79 days (IQR 37-219): 57 days (33-143) in true-positive and 162 days (44-248) in false-positive participants. Most participants had both laboratory tests (26 [79%] of 33 with true-positive results and 50 [88%] of 57 with false-positive results) and imaging (30 [91%] of 33 with true-positive results and 53 [93%] of 57 with false-positive results). Fewer procedures were done in participants with false-positive results (17 [30%] of 57) than true-positive results (27 [82%] of 33) and few had surgery (one with a false-positive result and three with a true-positive result). INTERPRETATION: This study supports the feasibility of MCED screening for cancer and underscores the need for further research investigating the test's clinical utility. FUNDING: GRAIL.


Asunto(s)
Ácidos Nucleicos Libres de Células , Neoplasias , Masculino , Humanos , Femenino , Estudios Prospectivos , Detección Precoz del Cáncer , Pruebas Hematológicas , Neoplasias/diagnóstico
2.
Gastroenterology ; 165(1): 252-266, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36948424

RESUMEN

BACKGROUND & AIMS: Colorectal cancer (CRC) screening guidelines include screening colonoscopy and sequential high-sensitivity fecal occult blood testing (HSgFOBT), with expectation of similar effectiveness based on the assumption of similar high adherence. However, adherence to screening colonoscopy compared with sequential HSgFOBT has not been reported. In this randomized clinical trial, we assessed adherence and pathology findings for a single screening colonoscopy vs sequential and nonsequential HSgFOBTs. METHODS: Participants aged 40-69 years were enrolled at 3 centers representing different clinical settings. Participants were randomized into a single screening colonoscopy arm vs sequential HSgFOBT arm composed of 4-7 rounds. Initial adherence to screening colonoscopy and sequential adherence to HSgFOBT, follow-up colonoscopy for positive HSgFOBT tests, crossover to colonoscopy, and detection of advanced neoplasia or large serrated lesions (ADN-SERs) were measured. RESULTS: There were 3523 participants included in the trial; 1761 and 1762 participants were randomized to the screening colonoscopy and HSgFOBT arms, respectively. Adherence was 1473 (83.6%) for the screening colonoscopy arm vs 1288 (73.1%) for the HSgFOBT arm after 1 round (relative risk [RR], 1.14; 95% CI, 1.10-1.19; P ≤ .001), but only 674 (38.3%) over 4 sequential HSgFOBT rounds (RR, 2.19; 95% CI, 2.05-2.33). Overall adherence to any screening increased to 1558 (88.5%) in the screening colonoscopy arm during the entire study period and 1493 (84.7%) in the HSgFOBT arm (RR, 1.04; 95% CI, 1.02-1.07). Four hundred thirty-six participants (24.7%) crossed over to screening colonoscopy during the first 4 rounds. ADN-SERs were detected in 121 of the 1473 participants (8.2%) in the colonoscopy arm who were adherent to protocol in the first 12 months of the study, whereas detection of ADN-SERs among those who were not sequentially adherent (n = 709) to HSgFOBT was subpar (0.6%) (RR, 14.72; 95% CI, 5.46-39.67) compared with those who were sequentially adherent (3.3%) (n = 647) (RR, 2.52; 95% CI, 1.61-3.98) to HSgFOBT in the first 4 rounds. When including colonoscopies from HSgFOBT patients who were never positive yet crossed over (n = 1483), 5.5% of ADN-SERs were detected (RR, 1.50; 95% CI, 1.15-1.96) in the first 4 rounds. CONCLUSIONS: Observed adherence to sequential rounds of HSgFOBT was suboptimal compared with a single screening colonoscopy. Detection of ADN-SERs was inferior when nonsequential HSgFOBT adherence was compared with sequential adherence. However, the greatest number of ADN-SERs was detected among those who crossed over to colonoscopy and opted to receive a colonoscopy. The effectiveness of an HSgFOBT screening program may be enhanced if crossover to screening colonoscopy is permitted. CLINICALTRIALS: gov, Number: NCT00102011.


Asunto(s)
Neoplasias Colorrectales , Sangre Oculta , Humanos , Colonoscopía , Tamizaje Masivo/métodos , Pruebas Hematológicas , Neoplasias Colorrectales/diagnóstico , Detección Precoz del Cáncer/métodos
3.
J Clin Microbiol ; 62(2): e0128923, 2024 02 14.
Artículo en Inglés | MEDLINE | ID: mdl-38270458

RESUMEN

A rapid host transcriptional signature cartridge could be a major advancement for tuberculosis diagnosis and treatment monitoring. In a recent study, M. Li, Y. Qiu, M. Guo, R. Qu, et al. (J Clin Microbiol 61:e00911-23, 2023, https://doi.org/10.1128/jcm.00911-23) conducted an evaluation of the Cepheid 3-gene assay (Xpert-MTB-HR) within a diagnostic case-control study in China. While the study provides a strong contribution for determining the value of the Xpert-MTB-HR assay for diagnostic accuracy and treatment response, further assay optimization and more prospective studies are necessary before adaptation into clinical practice.


Asunto(s)
Mycobacterium tuberculosis , Tuberculosis , Humanos , Mycobacterium tuberculosis/genética , Estudios de Casos y Controles , Estudios Prospectivos , Sensibilidad y Especificidad , Tuberculosis/diagnóstico , Pruebas Hematológicas
4.
Clin Chem ; 70(3): 551-561, 2024 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-38299916

RESUMEN

BACKGROUND: Tuberculosis (TB) remains a significant global health concern. Accurate detection of latent TB infection is crucial for effective control and prevention. We aimed to assess the performance of an interferon-gamma release assay blood test (QuantiFERON-TB Gold Plus [QFT-Plus]) in various clinical contexts and identify conditions that affect its results. METHODS: We conducted a retrospective analysis of 31 000 QFT-Plus samples collected from 26 000 subjects at a tertiary hospital in South Korea over a 4-year period and compared the rates of positivity and indeterminate results across diverse clinical situations. We also analysed the contribution of the QuantiFERON TB2 tube to the test's sensitivity and determined optimal cutoff values for 3 hematologic parameters to distinguish false-negative results. These cutoff values were validated in a separate cohort of subjects with microbiologically confirmed subclinical TB. RESULTS: Rates of QFT-Plus positivity and indeterminate results were disparate across diagnoses. The TB2 tube increased QFT-Plus sensitivity by 4.1% (95% CI, 1.1%-7.0%) in patients with subclinical TB. Absolute lymphocyte count ≤1.19 × 109/L, absolute neutrophil count ≥5.88 × 109/L, and neutrophil-to-lymphocyte ratio ≥4.33 were effective criteria to discriminate false-negative QFT-Plus results. Application of the hematologic criteria, individually or combined with mitogen response <10 IU/mL, substantially improved performance in the main study cohort and the validation cohort. CONCLUSIONS: These findings highlight the influence of clinical context and patient hematologic profiles on QFT-Plus results. To minimise neglected latent TB infections due to false-negative QFT-Plus results, serial retesting is advisable in patients with severe lymphopenia or neutrophilia, particularly when the mitogen response is <10 IU/mL.


Asunto(s)
Tuberculosis Latente , Tuberculosis , Humanos , Tuberculosis Latente/diagnóstico , Ensayos de Liberación de Interferón gamma , Estudios Retrospectivos , Mitógenos , Tuberculosis/diagnóstico , Pruebas Hematológicas
5.
Rheumatology (Oxford) ; 63(2): 525-533, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37208196

RESUMEN

OBJECTIVE: Disease activity monitoring in SLE includes serial measurement of anti-double stranded-DNA (dsDNA) antibodies, but in patients who are persistently anti-dsDNA positive, the utility of repeated measurement is unclear. We investigated the usefulness of serial anti-dsDNA testing in predicting flare in SLE patients who are persistently anti-dsDNA positive. METHODS: Data were analysed from patients in a multinational longitudinal cohort with known anti-dsDNA results from 2013 to 2021. Patients were categorized based on their anti-dsDNA results as persistently negative, fluctuating or persistently positive. Cox regression models were used to examine longitudinal associations of anti-dsDNA results with flare. RESULTS: Data from 37 582 visits of 3484 patients were analysed. Of the patients 1029 (29.5%) had persistently positive anti-dsDNA and 1195 (34.3%) had fluctuating results. Anti-dsDNA expressed as a ratio to the normal cut-off was associated with the risk of subsequent flare, including in the persistently positive cohort (adjusted hazard ratio [HR] 1.56; 95% CI: 1.30, 1.87; P < 0.001) and fluctuating cohort (adjusted HR 1.46; 95% CI: 1.28, 1.66), both for a ratio >3. Both increases and decreases in anti-dsDNA more than 2-fold compared with the previous visit were associated with increased risk of flare in the fluctuating cohort (adjusted HR 1.33; 95% CI: 1.08, 1.65; P = 0.008) and the persistently positive cohort (adjusted HR 1.36; 95% CI: 1.08, 1.71; P = 0.009). CONCLUSION: Absolute value and change in anti-dsDNA titres predict flares, including in persistently anti-dsDNA positive patients. This indicates that repeat monitoring of dsDNA has value in routine testing.


Asunto(s)
Anticuerpos Antinucleares , Lupus Eritematoso Sistémico , Humanos , ADN , Recolección de Datos , Pruebas Hematológicas
6.
Microb Pathog ; 189: 106587, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38373644

RESUMEN

BACKGROUND: The condition of COVID-19-related myocarditis has emerged as a prominent contributor to COVID-19 mortality. As the epidemic persists, its incidence continues to rise. Despite ongoing efforts, the elucidation of COVID-19-related myocarditis underlying molecular mechanisms still requires further investigation. METHODS: Hub genes for COVID-19-related myocarditis were screened by integrating gene expression profile analysis via differential expression in COVID-19 (GSE196822) and myocarditis (GSE148153 and GSE147517). After verification with independent datasets (GSE211979, GSE167028, GSE178491 and GSE215865), the hub genes were studied using a range of systems-biology approaches, such as ceRNA, TF-mRNA networks and PPI networks, as well as gene ontology, pathway enrichment, immune infiltration analysis and drug target identification. RESULTS: TBKBP1 and ERGIC1 were identified as COVID-19-related myocarditis hub genes via integrated bioinformatics analysis. In addition, receiver operating characteristic curves constructed based on the expression levels of TBKBP1 and ERGIC1 could effectively distinguish healthy control individuals from patients with COVID-19. Functional enrichment analysis suggested several enriched biological pathways related to inflammation and immune response. Immune cell changes correlated with TBKBP1 and ERGIC1 levels in patients with COVID-19 or patients with COVID-19 and myocarditis. Tamibarotene, methotrexate and theophylline were identified as a potential drug targeting TBKBP1 and ERGIC1. CONCLUSION: TBKBP1 and ERGIC1 were identified as crucial genes in the development of COVID-19-related myocarditis and have demonstrated a strong association with innate antiviral immunity. The present work may be helpful for further investigation of the molecular mechanisms and new therapeutic drug targets correlated with myocarditis in COVID-19.


Asunto(s)
COVID-19 , Miocarditis , Humanos , Transcriptoma , Miocarditis/genética , Pruebas Hematológicas , Perfilación de la Expresión Génica , Biología Computacional
7.
Stem Cells ; 41(4): 310-318, 2023 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-36881778

RESUMEN

Cancer continues to remain a "Black Box," as there is no consensus on how it initiates, progresses, metastasizes, or recurs. Many imponderables exist about whether somatic mutations initiate cancer, do cancer stem cells (CSCs) exist, and if yes, are they a result of de-differentiation or originate from tissue-resident stem cells; why do cancer cells express embryonic markers, and what leads to metastasis and recurrence. Currently, the detection of multiple solid cancers through liquid biopsy is based on circulating tumor cells (CTCs) or clusters, or circulating tumor DNA (ctDNA). However, quantity of starting material is usually adequate only when the tumor has grown beyond a certain size. We posit that pluripotent, endogenous, tissue-resident, very small embryonic-like stem cells (VSELs) that exist in small numbers in all adult tissues, exit from their quiescent state due to epigenetic changes in response to various insults and transform into CSCs to initiate cancer. VSELs and CSCs share properties like quiescence, pluripotency, self-renewal, immortality, plasticity, enrichment in side-population, mobilization, and resistance to oncotherapy. HrC test, developed by Epigeneres, offers the potential for early detection of cancer using a common set of VSEL/CSC specific bio-markers in peripheral blood. In addition, NGS studies on VSELs/CSCs/tissue-specific progenitors using the All Organ Biopsy (AOB) test provide exomic and transcriptomic information regarding impacted organ(s), cancer type/subtype, germline/somatic mutations, altered gene expressions, and dysregulated pathways. To conclude, HrC and AOB tests can confirm the absence of cancer and categorize the rest of subjects into low/moderate/high risk of cancer, and also monitor response to therapy, remission, and recurrence.


Asunto(s)
Neoplasias , Células Madre Pluripotentes , Adulto , Humanos , Células Madre Embrionarias/metabolismo , Diferenciación Celular , Células Madre Neoplásicas , Pruebas Hematológicas , Neoplasias/diagnóstico , Neoplasias/patología
8.
Br J Dermatol ; 190(4): 559-564, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-37931161

RESUMEN

BACKGROUND: There is no evidence base to support the use of 6-monthly monitoring blood tests for the early detection of liver, blood and renal toxicity during established anti-tumour necrosis factor alpha (TNFα) treatment. OBJECTIVES: To evaluate the incidence and risk factors of anti-TNFα treatment cessation owing to liver, blood and renal side-effects, and to estimate the cost-effectiveness of alternate intervals between monitoring blood tests. METHODS: A secondary care-based retrospective cohort study was performed. Data from the British Association of Dermatologists Biologic and Immunomodulators Register (BADBIR) were used. Patients with at least moderate psoriasis prescribed their first anti-TNFα treatment were included. Treatment discontinuation due to a monitoring blood test abnormality was the primary outcome. Patients were followed-up from start of treatment to the outcome of interest, drug discontinuation, death, 31 July 2021 or up to 5 years, whichever came first. The incidence rate (IR) and 95% confidence intervals (CIs) of anti-TNFα discontinuation with monitoring blood test abnormality was calculated. Multivariate Cox regression was used to examine the association between risk factors and outcome. A mathematical model evaluated costs and quality-adjusted life years (QALYs) associated with increasing the length of time between monitoring blood tests during anti-TNFα treatment. RESULTS: The cohort included 8819 participants [3710 (42.1%) female, mean (SD) age 44.76 (13.20) years] that contributed 25 058 person-years (PY) of follow-up and experienced 125 treatment discontinuations owing to a monitoring blood test abnormality at an IR of 5.85 (95% CI 4.91-6.97)/1000 PY. Of these, 64 and 61 discontinuations occurred within the first year and after the first year of treatment start, at IRs of 8.62 (95% CI 6.74-11.01) and 3.44 (95% CI 2.67-4.42)/1000 PY, respectively. Increasing age (in years), diabetes and liver disease were associated with anti-TNFα discontinuation after a monitoring blood test abnormality [adjusted hazard ratios of 1.02 (95% CI 1.01-1.04), 1.68 (95% CI 1.00-2.81) and 2.27 (95% CI 1.26-4.07), respectively]. Assuming a threshold of £20 000 per QALY gained, no monitoring was most cost-effective, but all extended periods were cost-effective vs. 3- or 6-monthly monitoring. CONCLUSIONS: Anti-TNFα drugs were uncommonly discontinued owing to abnormal monitoring blood tests after the first year of treatment. Extending the duration between monitoring blood tests was cost-effective. Our results produce evidence for specialist society guidance to reduce patient monitoring burden and healthcare costs.


Asunto(s)
Pruebas Hematológicas , Factor de Necrosis Tumoral alfa , Humanos , Femenino , Adulto , Masculino , Análisis Costo-Beneficio , Estudios Retrospectivos , Necrosis , Años de Vida Ajustados por Calidad de Vida
9.
Vox Sang ; 119(6): 556-562, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38523360

RESUMEN

BACKGROUND AND OBJECTIVES: Malaria continues to be a significant public health concern in India, with several regions experiencing endemicity and sporadic outbreaks. The prevalence of malaria in blood donors, in India, varies between 0.02% and 0.07%. Common techniques to screen for malaria, in blood donors and patients, include microscopic smear examination and rapid diagnostic tests (RDTs) based on antigen detection. The aim of this study was to evaluate a new fully automated analyser, XN-31, for malaria detection, as compared with current practice of using RDT. MATERIALS AND METHODS: Cross-sectional analytical study was conducted to evaluate clinical sensitivity and specificity of new automated analyser XN-31 among blood donors' samples and clinical samples (patients with suspicion of malaria) from outpatient clinic collected over between July 2021 and October 2022. No additional sample was drawn from blood donor or patient. All blood donors and patients' samples were processed by malaria rapid diagnostic test, thick-smear microscopy (MIC) and the haematology analyser XN-31. Any donor blood unit incriminated for malaria was discarded. Laboratory diagnosis using MIC was considered the 'gold standard' in the present study. Clinical sensitivity and specificity of XN-31 were compared with the gold standard. RESULTS: Fife thousand and five donor samples and 82 diagnostic samples were evaluated. While the clinical sensitivity and specificity for donor samples were 100%, they were 72.7% and 100% for diagnostic samples. CONCLUSION: Automated haematology analysers represent a promising solution, as they can deliver speedy and sensitive donor malaria screening assessments. This method also has the potential to be used for pre-transfusion malaria screening along with haemoglobin estimation.


Asunto(s)
Donantes de Sangre , Malaria , Humanos , India , Malaria/diagnóstico , Malaria/sangre , Estudios Transversales , Femenino , Masculino , Sensibilidad y Especificidad , Adulto , Pruebas Hematológicas/métodos , Pruebas Hematológicas/instrumentación
10.
Environ Sci Technol ; 58(4): 1802-1812, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38217501

RESUMEN

Humans interact with thousands of chemicals. This study aims to identify substances of emerging concern and in need of human health risk evaluations. Sixteen pooled human serum samples were constructed from 25 individual samples each from the National Institute of Environmental Health Sciences' Clinical Research Unit. Samples were analyzed using gas chromatography (GC) × GC/time-of-flight (TOF)-mass spectrometry (MS) in a suspect screening analysis, with follow-up confirmation analysis of 19 substances. A standard reference material blood sample was also analyzed through the confirmation process for comparison. The pools were stratified by sex (female and male) and by age (≤45 and >45). Publicly available information on potential exposure sources was aggregated to annotate presence in serum as either endogenous, food/nutrient, drug, commerce, or contaminant. Of the 544 unique substances tentatively identified by spectral matching, 472 were identified in females, while only 271 were identified in males. Surprisingly, 273 of the identified substances were found only in females. It is known that behavior and near-field environments can drive exposures, and this work demonstrates the existence of exposure sources uniquely relevant to females.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas , Pruebas Hematológicas , Femenino , Humanos , Masculino , Cromatografía de Gases y Espectrometría de Masas/métodos , Pruebas Hematológicas/métodos , Adulto , Persona de Mediana Edad
11.
Transpl Int ; 37: 12864, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38832357

RESUMEN

Simultaneous pancreas-kidney (SPK) transplantation improves quality of life and limits progression of diabetic complications. There is reluctance to accept pancreata from donors with abnormal blood tests, due to concern of inferior outcomes. We investigated whether donor amylase and liver blood tests (markers of visceral ischaemic injury) predict pancreas graft outcome using the UK Transplant Registry (2016-2021). 857 SPK recipients were included (619 following brainstem death, 238 following circulatory death). Peak donor amylase ranged from 8 to 3300 U/L (median = 70), and this had no impact on pancreas graft survival when adjusting for multiple confounders (aHR = 0.944, 95% CI = 0.754-1.81). Peak alanine transaminases also did not influence pancreas graft survival in multivariable models (aHR = 0.967, 95% CI = 0.848-1.102). Restricted cubic splines were used to assess associations between donor blood tests and pancreas graft survival without assuming linear relationships; these confirmed neither amylase, nor transaminases, significantly impact pancreas transplant outcome. This is the largest, most statistically robust study evaluating donor blood tests and transplant outcome. Provided other factors are acceptable, pancreata from donors with mild or moderately raised amylase and transaminases can be accepted with confidence. The use of pancreas grafts from such donors is therefore a safe, immediate, and simple approach to expand the donor pool to reach increasing demands.


Asunto(s)
Amilasas , Supervivencia de Injerto , Trasplante de Riñón , Trasplante de Páncreas , Donantes de Tejidos , Humanos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Amilasas/sangre , Estudios de Cohortes , Alanina Transaminasa/sangre , Reino Unido , Pruebas Hematológicas , Sistema de Registros
12.
Clin Chem Lab Med ; 62(2): 322-331, 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-37702323

RESUMEN

OBJECTIVES: Neurofilament light chain (NfL) has emerged as a promising biomarker for detecting and monitoring axonal injury. Until recently, NfL could only be reliably measured in cerebrospinal fluid, but digital single molecule array (Simoa) technology has enabled its precise measurement in blood samples where it is typically 50-100 times less abundant. We report development and multi-center validation of a novel fully automated digital immunoassay for NfL in serum for informing axonal injury status. METHODS: A 45-min immunoassay for serum NfL was developed for use on an automated digital analyzer based on Simoa technology. The analytical performance (sensitivity, precision, reproducibility, linearity, sample type) was characterized and then cross validated across 17 laboratories in 10 countries. Analytical performance for clinical NfL measurement was examined in individual patients with relapsing remitting multiple sclerosis (RRMS) after 3 months of disease modifying treatment (DMT) with fingolimod. RESULTS: The assay exhibited a lower limit of detection (LLoD) of 0.05 ng/L, a lower limit of quantification (LLoQ) of 0.8 ng/L, and between-laboratory imprecision <10 % across 17 validation sites. All tested samples had measurable NfL concentrations well above the LLoQ. In matched pre-post treatment samples, decreases in NfL were observed in 26/29 RRMS patients three months after DMT start, with significant decreases detected in a majority of patients. CONCLUSIONS: The sensitivity characteristics and reproducible performance across laboratories combined with full automation make this assay suitable for clinical use for NfL assessment, monitoring in individual patients, and cross-comparisons of results across multiple sites.


Asunto(s)
Filamentos Intermedios , Neuronas , Humanos , Reproducibilidad de los Resultados , Inmunoensayo , Proteínas de Neurofilamentos , Biomarcadores , Pruebas Hematológicas
13.
Methods ; 220: 55-60, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37951558

RESUMEN

AIMS: This study explores the possibility of using routinely taken blood tests in the diagnosis and triage of patients with suspected musculoskeletal malignancy. METHODS: A retrospective study was performed on results of patients who had presented for assessment to a regional musculoskeletal tumour unit. Blood results of patients with a histologically confirmed diagnosis between 2010 and 2020 were retrieved. 33 distinct blood tests were available for model forming. Results were standardised by calculating z-scores. Data were split into a training set (70%) and a test set (30%). The training set was balanced by resampling underrepresented classes. The random forest algorithm performed best and was selected for model forming. Receiver operating characteristic curves were used to find the optimum threshold. Models were calibrated and performance metrics evaluated with confusion tables. RESULTS: 2371 patients formed the study population. 1080 had a malignant diagnosis in one of three categories: sarcoma, metastasis, or haematological malignancy. 1291 had a benign condition. Metastasis could be predicted with an accuracy of 79% (AUC 87%, sensitivity 79%, specificity 80% NPV 91%). Haematological malignancy accuracy 79% (AUC 81%, sensitivity 77%, specificity 79%, NPV 97%). Sarcoma accuracy 64% (AUC 73%, sensitivity 76%, specificity 61%, NPV 88%) and all malignancy accuracy 74% (AUC 80%, sensitivity 72%, specificity 75%, NPV 76%). CONCLUSION: Routinely performed blood tests can be useful in triage of musculoskeletal tumours and can be used to predict presence of musculoskeletal malignancy.


Asunto(s)
Neoplasias Hematológicas , Sarcoma , Humanos , Estudios Retrospectivos , Pruebas Hematológicas , Aprendizaje Automático
14.
Nature ; 620(7976): 925, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37608023
15.
Environ Res ; 249: 118318, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38307179

RESUMEN

Coastal ecosystems are vital for maintaining the biodiversity and human livelihoods, but they are increasingly subjected to anthropogenic pressures, including pollution from various sources. Present work intends to assess the possible threats in coastal ecosystem as well as coastal fish species, in particular, through haematological parameters caused due to exposure of environmental contaminants like polycyclic aromatic hydrocarbons (PAHs), potentially toxic metals (PTMs), etc. This study analysed the haematological parameters and probable toxicity levels in two important coastal fish species, viz., Mystus sp. and Mugil sp. widely available in Digha coastal belt. Different haematological parameters, such as WBCs (White Blood Cells), Lym (Lymphocytes), Gran (Granulocytes), Mid (Monocytes), RBCs (Red Blood Cells), HCT (Haematocrit) value, MCV (Mean Corpuscular Volume), MCH (Mean Corpuscular Haemoglobin), MCHC (Mean Corpuscular Haemoglobin Concentration), RDW- CV (Red Cells Distribution Width-Co-efficient of Variation), RDW- SD (Red Cells Distribution Width-Standard Deviation), PLT (Total Platelet Count), MPV (Mean Platelet Volume), PDW- SD (Platelet Distribution Width-Standard Deviation), PDW- CV (Platelet Distribution Width-Co-efficient of Variation), PCT (Plateletcrit), PLCR (Platelet Large Cell Ratio), PLCC (Platelet Large Cell Count) and many others were measured directly through Erba H360 Haematology Analyser, simultaneously air dried blood smear was stained by Haematoxylin-Eosin(H-E) and Giemsa stain for assessing morphometric alterations of RBCs, WBCs, platelets as well as to determine the differential counts of WBCs by observing through Leica DM2000 microscope. Evidence of several abnormalities in the erythrocyte's nucleus (ENAs) and the abundance of abnormal celled erythrocytes (ECAs), carcinoma (lymphoproliferative disorder, polycythaemia vera, Hodgkin lymphoma and non-Hodgkin lymphoma), elevation of WBCs content, Lym %(Lymphocyte percentage), Eo(Eosinophils), monocytes, HCT and gross depletion of Ne(Neutrophils), basophils, and PLCR levels indicated a sign of major impact of contamination to two intoxicated fishes which may also affect the human being through food chain and may result into leukaemia in mammalian species, finally. However, comprehensive evaluation of the long-term impacts of the contaminants like PAHs and/or PTMs, etc., on fish populations, human health risk and coastal ecosystem is required to be addressed.


Asunto(s)
Contaminantes Químicos del Agua , Animales , India , Contaminantes Químicos del Agua/toxicidad , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/sangre , Peces , Monitoreo del Ambiente/métodos , Pruebas Hematológicas , Hidrocarburos Policíclicos Aromáticos/toxicidad , Hidrocarburos Policíclicos Aromáticos/análisis
16.
Clin Lab ; 70(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38469786

RESUMEN

BACKGROUND: Hemoglobin A1C (HbA1C) is used to evaluate glycemic control over a three-month period. Blood matrix-based HbA1C materials are needed for quality control and evaluation of HbA1C measurements. This study investigated the commutability of blood materials (BMs) and aimed to upgrade BMs for HbA1C testing for use as proficiency test (PT) material. METHODS: We measured BMs from a DM blood donor (n = 1), an in vitro glycation procedure (n = 3), and from commercial sources (n = 2) for HbA1C in parallel with fresh unprocessed BMs (n = 3) and clinical blood samples (n = 25). Two NGSP-certified methods, including a turbidimetric and an enzymatic immunoassay, were used for HbA1C determinations. Commutability as investigated according to CLSI EP14-Ed4 guidelines. RESULTS: The commutable BMs exhibited a mean paired difference of 0% to 9% when compared to reference methods, whereas the non-commutable BMs represented a mean paired difference of 3% to 11%. Fresh, unprocessed BMs with a low HbA1C of 6.0% were more commutable than BMs with a high HbA1C. The values of HbA1C in BMs (mean and uncertainty following ISO Guide 35 for RM production) were applied to upgrade the PT material to be used as a reference material. The relative uncertainty of BM-Ndm-1 and BM-Gcb-3 were 1 and 0.4%, respectively. CONCLUSIONS: The commutability of hemoglobin in BMs is dependent on the preparation process. Blood materials with a high HbA1C content are usually less commutable versus materials with low HbA1C content when prepared by the same process. Our study showed BMs can be successfully used as quality control or PT materials.


Asunto(s)
Pruebas Hematológicas , Humanos , Estándares de Referencia , Hemoglobina Glucada , Incertidumbre , Control de Calidad
17.
Clin Lab ; 70(6)2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38868884

RESUMEN

BACKGROUND: Reference intervals are essential for the interpretation of clinical laboratory tests and patient management. This study aims to determine age and gender reference intervals of complete blood count (CBC) in the Moroccan population by using the indirect approach. METHODS: The study used data of ostensibly healthy adults collected retrospectively using the laboratory information system (LIS) of the Laboratory for Research and Medical Analysis of the Fraternal Royal Gendarmerie in Rabat (Morocco), between January 2018 and February 2020. The study included 5,898 men and 10,172 women ranging in age from 18 to 90 years. The lower and upper reference limits of CBC parameters were calculated using the nonparametric technique, as suggested by the Clinical and Laboratory Standards Institute (CLSI). RESULTS: All hematological parameters showed no clinically significant gender-related differences, except small differences in the values of hemoglobin (HB), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC). There were also no clinically significant agerelated differences for median values of all hematology analytes in both genders, except for platelet count (PLT) that continued to decline with increasing age in men and women, and Red blood cell count (RBC), Hematocrit (HCT), and hemoglobin (HB) that tended to increase with age but decrease in older age groups in men while they tended to increase with age in women. CONCLUSIONS: The indirect method can be used to establish reference intervals for CBC, with appropriate selection criteria and statistical tools. Our findings differed from the reference ranges provided in the textbook and also in other countries' reports.


Asunto(s)
Pacientes Ambulatorios , Humanos , Adulto , Masculino , Femenino , Valores de Referencia , Persona de Mediana Edad , Marruecos , Anciano , Adulto Joven , Adolescente , Anciano de 80 o más Años , Estudios Retrospectivos , Recuento de Células Sanguíneas/normas , Recuento de Células Sanguíneas/estadística & datos numéricos , Pacientes Ambulatorios/estadística & datos numéricos , Índices de Eritrocitos , Hemoglobinas/análisis , Hematócrito , Factores de Edad , Factores Sexuales , Pruebas Hematológicas/normas , Pruebas Hematológicas/métodos
18.
Scand J Clin Lab Invest ; 84(1): 11-15, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38240284

RESUMEN

The objective of the study was to evaluate Capitainer's quantitative dried blood spots (qDBS) card for Hemoglobin A1c (HbA1c) testing. qDBS cards can be used for at-home sampling for HbA1c determination in a Swedish laboratory setting. A total of 153 routine requested HbA1c samples were used in this evaluation of microfluidic cards (qDBS). The HbA1c was extracted from the disc and HbA1c was determined at cobas 6000 instruments with immunological technology. The results were compared with results from traditional venous HbA1c testing. The reproducibility of using this elution procedure was 4.0% measured as coefficient of variation at a HbA1c concentration of 51 mmol/mol. Analytical performance specifications for HbA1c < 52 mmol/mol using DBS card (c501) compared with assigned values from Capillarys 3 was (y) = 1.03 x Capillarys 3(x) - 0.87; R2 = 0.97. There is a good agreement between HbA1c determined by traditional HbA1c testing and determination from Capitainer's qDBS cards. This shows that the technology could be used for out-of doctor's office testing.


Asunto(s)
Pruebas Hematológicas , Microfluídica , Humanos , Hemoglobina Glucada , Reproducibilidad de los Resultados , Pruebas con Sangre Seca
19.
Anaesthesia ; 79(2): 178-185, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37990621

RESUMEN

Point-of-care haemoglobin measurement devices may play an important role in the antenatal detection of anaemia in pregnant people and may be useful in guiding blood transfusion during resuscitation in obstetric haemorrhage. We compared baseline haemoglobin variability of venous and capillary HemoCue® haemoglobin, and Masimo® Rad-67 Pulse CO-Oximeter haemoglobin with laboratory haemoglobin in people on the day of their planned vaginal birth. A total of 180 people undergoing planned vaginal birth were enrolled in this prospective observational study. Laboratory haemoglobin was compared with HemoCue and Masimo Rad-67 Pulse CO-Oximeter measurements using Bland-Altman analysis, calculating mean difference (bias) and limits of agreement. Five (2.8%) people had anaemia (haemoglobin < 110 g.l-1 ). Laboratory haemoglobin and HemoCue venous haemoglobin comparison showed an acceptable bias (SD) 0.7 (7.54) g.l-1 (95%CI -0.43-1.79), with limits of agreement -14.10-15.46 g.l-1 and acceptable agreement range of 29.6 g.l-1 . Laboratory and HemoCue capillary haemoglobin comparison showed an unacceptable bias (SD) 13.3 (14.12) g.l-1 (95%CI 11.17-15.34), with limits of agreement - 14.42-40.93 g.l-1 and unacceptable agreement range of 55.3 g.l-1 . Laboratory and Masimo haemoglobin comparison showed an unacceptable bias (SD) -14.0 (11.15) g.l-1 (95%CI -15.63 to -12.34), with limits of agreement to -35.85 to 7.87 g.l-1 and acceptable agreement range of 43.7 g.l-1 . Venous HemoCue, with its acceptable bias and limits of agreement, should be applied more widely in the antenatal setting to detect, manage and risk stratify pregnant people with anaemia. HemoCue capillary measurement under-estimated haemoglobin and Masimo haemoglobin measurement over-estimated, limiting their clinical use. Serial studies are needed to determine if the accuracy of venous HemoCue haemoglobin measurement is sustained in other obstetric settings.


Asunto(s)
Anemia , Hemoglobinas , Humanos , Femenino , Embarazo , Hemoglobinometría/métodos , Hemoglobinas/análisis , Oximetría/métodos , Anemia/diagnóstico , Pruebas Hematológicas , Oxígeno
20.
BMC Pediatr ; 24(1): 328, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741033

RESUMEN

BACKGROUND: The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), influenza A, and respiratory syncytial virus (RSV) infections have similar modes of transmission and clinical symptoms. There is a need to identify simple diagnostic indicators to distinguish these three infections, particularly for community hospitals and low- and middle-income countries that lack nucleic acid detection kits. This study used clinical data to assess the diagnostic value of routine blood tests in differentiating between SARS-CoV-2, influenza A, and RSV infections in children. METHODS: A total of 1420 children treated at the Hangzhou Children's Hospital between December 2022 and June 2023 were enrolled in this study, of whom 351 had SARS-CoV-2, 671 had influenza, and 398 had RSV. In addition, 243 healthy children were also collected. The blood test results of SARS-CoV-2 patients were compared to those of patients with influenza A and RSV and the healthy controls. The area under the receiver operating characteristic curve (AUC-ROC) was employed to evaluate each blood parameter's diagnostic value. RESULTS: Children with SARS-CoV-2 exhibited notably elevated levels of white blood cell (WBC) count, platelet (PLT) count, neutrophil count, and neutrophil-to-lymphocyte ratio (NLR) compared to influenza A patients (P < 0.05). In contrast, SARS-CoV-2 patients exhibited a decrease in the mean platelet volume to platelet count ratio (MPV/PLT) and the lymphocyte-to-monocyte ratio (LMR) when compared to other individuals (P < 0.05). These parameters had an AUC between 0.5 and 0.7. Compared to patients with RSV, SARS-CoV-2 patients had significantly higher MPV/PLT and significantly lower WBC, lymphocyte, PLT, LMR, and lymphocyte multiplied by platelet (LYM*PLT) values (P < 0.05). However, only LYM*PLT had an acceptable diagnostic value above 0.7 for all age groups. Compared to healthy children, children with COVID-19 exhibited elevated NLR and MPV/PLT levels, alongside decreased lymphocyte, PLT, LMR, and LYM*PLT values. (P < 0.05). The AUC of the LMR, LYM*PLT, and PLT were above 0.7 in all age groups, indicating promising diagnostic values. CONCLUSIONS: The routine blood parameters among patients with COVID-19, influenza A, and RSV differ significantly early in the disease and could be used by clinicians to discriminate between the 3 types of infection.


Asunto(s)
COVID-19 , Gripe Humana , Infecciones por Virus Sincitial Respiratorio , Humanos , COVID-19/diagnóstico , COVID-19/sangre , Estudios Retrospectivos , Gripe Humana/diagnóstico , Gripe Humana/sangre , Masculino , Femenino , Niño , Preescolar , Infecciones por Virus Sincitial Respiratorio/diagnóstico , Infecciones por Virus Sincitial Respiratorio/sangre , Diagnóstico Diferencial , Lactante , Curva ROC , Adolescente , Pruebas Hematológicas/métodos , Niño Hospitalizado , SARS-CoV-2 , China
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA