Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.542
Filtrar
Más filtros

Intervalo de año de publicación
1.
Am J Physiol Heart Circ Physiol ; 326(6): H1350-H1365, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38551483

RESUMEN

Premature ventricular complexes (PVCs) are spontaneous excitations occurring in the ventricles of the heart that are associated with ventricular arrhythmias and sudden cardiac death. Under long QT conditions, PVCs can be mediated by repolarization gradient (RG) and early afterdepolarizations (EADs), yet the effects of heterogeneities or geometry of the RG or EAD regions on PVC genesis remain incompletely understood. In this study, we use computer simulation to systematically investigate the effects of the curvature of the RG border region on PVC genesis under long QT conditions. We show that PVCs can be either promoted or suppressed by negative or positive RG border curvature depending on the source and sink conditions. When the origin of oscillation is in the source region and the source is too strong, a positive RG border curvature can promote PVCs by causing the source area to oscillate. When the origin of oscillation is in the sink region, a negative RG border curvature can promote PVCs by causing the sink area to oscillate. Furthermore, EAD-mediated PVCs are also promoted by negative border curvature. We also investigate the effects of wavefront curvature and show that PVCs are promoted by convex but suppressed by concave wavefronts; however, the effect of wavefront curvature is much smaller than that of RG border curvature. In conclusion, besides the increase of RG and occurrence of EADs caused by QT prolongation, the geometry of the RG border plays important roles in PVC genesis, which can greatly increase the risk of arrhythmias in cardiac diseases.NEW & NOTEWORTHY The effects of the curvature or geometry of the repolarization gradient region and wavefront curvature on the genesis of premature ventricular complexes are systematically investigated using computer modeling and simulation. Premature ventricular complexes can be promoted by either positive or negative curvature of the gradient region depending on the source and sink conditions. The underlying mechanisms of the curvature effects are revealed, which provides mechanistic insights into arrhythmogenesis in cardiac diseases.


Asunto(s)
Simulación por Computador , Síndrome de QT Prolongado , Modelos Cardiovasculares , Complejos Prematuros Ventriculares , Complejos Prematuros Ventriculares/fisiopatología , Humanos , Síndrome de QT Prolongado/fisiopatología , Potenciales de Acción , Frecuencia Cardíaca , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología
2.
J Cardiovasc Electrophysiol ; 35(7): 1370-1381, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38725227

RESUMEN

INTRODUCTION: Although prior studies indicate that a QTc > 500 ms on a single baseline 12-lead electrocardiogram (ECG) is associated with significantly increased risk of arrhythmic events in long QT syndrome (LQTS), less is known about the risk of persistent QT prolongation. We sought to determine QTc persistence and its prognostic effect on breakthrough cardiac events (BCEs) among pediatric patients treated for LQTS. METHODS: We performed a retrospective analysis of 433 patients with LQTS evaluated, risk-stratified, and undergoing active guideline-based LQTS treatment between 1999 and 2019. BCEs were defined as arrhythmogenic syncope/seizure, sudden cardiac arrest (SCA), appropriate VF-terminating ICD shock, and sudden cardiac death (SCD). RESULTS: During the median follow-up of 5.5 years (interquartile range [IQR] = 3-9), 32 (7%) patients experienced a total of 129 BCEs. A maximum QTc threshold of 520 ms and median QTc threshold of 490 ms were determined to be strong predictors for BCEs. A landmark analysis controlling for age, sex, genotype, and symptomatic status demonstrated models utilizing both the median QTc and maximum QTc demonstrated the highest discriminatory value (c-statistic = 0.93-0.95). Patients in the high-risk group (median QTc > 490 ms and maximum QTc > 520 ms) had a significantly lower BCE free survival (70%-81%) when compared to patients in both medium-risk (93%-97%) and low-risk (98%-99%) groups. CONCLUSIONS: The risk of BCE among patients treated for LQTS increases not only based upon their maximum QTc, but also their median QTc (persistence of QTc prolongation). Patients with a maximum QTc > 520 ms and median QTc > 490 ms over serial 12-lead ECGs are at the highest risk of BCE while on guideline-directed medical therapy.


Asunto(s)
Potenciales de Acción , Muerte Súbita Cardíaca , Electrocardiografía , Frecuencia Cardíaca , Síndrome de QT Prolongado , Valor Predictivo de las Pruebas , Humanos , Masculino , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/fisiopatología , Femenino , Estudios Retrospectivos , Niño , Medición de Riesgo , Factores de Riesgo , Adolescente , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Preescolar , Factores de Tiempo , Factores de Edad , Lactante , Resultado del Tratamiento , Sistema de Conducción Cardíaco/fisiopatología
3.
J Cardiovasc Magn Reson ; 26(1): 101009, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38342406

RESUMEN

BACKGROUND: The 12-lead electrocardiogram (ECG) is a standard diagnostic tool for monitoring cardiac ischemia and heart rhythm during cardiac interventional procedures and stress testing. These procedures can benefit from magnetic resonance imaging (MRI) information; however, the MRI scanner magnetic field leads to ECG distortion that limits ECG interpretation. This study evaluated the potential for improved ECG interpretation in a "low field" 0.55T MRI scanner. METHODS: The 12-lead ECGs were recorded inside 0.55T, 1.5T, and 3T MRI scanners, as well as at scanner table "home" position in the fringe field and outside the scanner room (seven pigs). To assess interpretation of ischemic ECG changes in a 0.55T MRI scanner, ECGs were recorded before and after coronary artery occlusion (seven pigs). ECGs was also recorded for five healthy human volunteers in the 0.55T scanner. ECG error and variation were assessed over 2-minute recordings for ECG features relevant to clinical interpretation: the PR interval, QRS interval, J point, and ST segment. RESULTS: ECG error was lower at 0.55T compared to higher field scanners. Only at 0.55T table home position, did the error approach the guideline recommended 0.025 mV ceiling for ECG distortion (median 0.03 mV). At scanner isocenter, only in the 0.55T scanner did J point error fall within the 0.1 mV threshold for detecting myocardial ischemia (median 0.03 mV in pigs and 0.06 mV in healthy volunteers). Correlation of J point deviation inside versus outside the 0.55T scanner following coronary artery occlusion was excellent at scanner table home position (r2 = 0.97), and strong at scanner isocenter (r2 = 0.92). CONCLUSION: ECG distortion is improved in 0.55T compared to 1.5T and 3T MRI scanners. At scanner home position, ECG distortion at 0.55T is low enough that clinical interpretation appears feasible without need for more cumbersome patient repositioning. At 0.55T scanner isocenter, ST segment changes during coronary artery occlusion appear detectable but distortion is enough to obscure subtle ST segment changes that could be clinically relevant. Reduced ECG distortion in 0.55T scanners may simplify the problem of suppressing residual distortion by ECG cable positioning, averaging, and filtering and could reduce current restrictions on ECG monitoring during interventional MRI procedures.


Asunto(s)
Electrocardiografía , Frecuencia Cardíaca , Imagen por Resonancia Magnética , Valor Predictivo de las Pruebas , Electrocardiografía/instrumentación , Animales , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/instrumentación , Masculino , Modelos Animales de Enfermedad , Potenciales de Acción , Femenino , Factores de Tiempo , Sus scrofa , Artefactos , Adulto , Persona de Mediana Edad , Procesamiento de Señales Asistido por Computador , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/diagnóstico por imagen , Porcinos
4.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38875491

RESUMEN

AIMS: Patients with mutations in SCN5A encoding NaV1.5 often display variable severity of electrical and structural alterations, but the underlying mechanisms are not fully elucidated. We here investigate the combined modulatory effect of genetic background and age on disease severity in the Scn5a1798insD/+ mouse model. METHODS AND RESULTS: In vivo electrocardiogram and echocardiograms, ex vivo electrical and optical mapping, and histological analyses were performed in adult (2-7 months) and aged (8-28 months) wild-type (WT) and Scn5a1798insD/+ (mutant, MUT) mice from the FVB/N and 129P2 inbred strains. Atrio-ventricular (AV) conduction, ventricular conduction, and ventricular repolarization are modulated by strain, genotype, and age. An aging effect was present in MUT mice, with aged MUT mice of both strains showing prolonged QRS interval and right ventricular (RV) conduction slowing. 129P2-MUT mice were severely affected, with adult and aged 129P2-MUT mice displaying AV and ventricular conduction slowing, prolonged repolarization, and spontaneous arrhythmias. In addition, the 129P2 strain appeared particularly susceptible to age-dependent electrical, functional, and structural alterations including RV conduction slowing, reduced left ventricular (LV) ejection fraction, RV dilatation, and myocardial fibrosis as compared to FVB/N mice. Overall, aged 129P2-MUT mice displayed the most severe conduction defects, RV dilatation, and myocardial fibrosis, in addition to the highest frequency of spontaneous arrhythmia and inducible arrhythmias. CONCLUSION: Genetic background and age both modulate disease severity in Scn5a1798insD/+ mice and hence may explain, at least in part, the variable disease expressivity observed in patients with SCN5A mutations. Age- and genetic background-dependent development of cardiac structural alterations furthermore impacts arrhythmia risk. Our findings therefore emphasize the importance of continued assessment of cardiac structure and function in patients carrying SCN5A mutations.


Asunto(s)
Arritmias Cardíacas , Modelos Animales de Enfermedad , Fibrosis , Predisposición Genética a la Enfermedad , Mutación , Canal de Sodio Activado por Voltaje NAV1.5 , Animales , Canal de Sodio Activado por Voltaje NAV1.5/genética , Arritmias Cardíacas/genética , Arritmias Cardíacas/fisiopatología , Factores de Edad , Índice de Severidad de la Enfermedad , Sistema de Conducción Cardíaco/fisiopatología , Potenciales de Acción , Electrocardiografía , Fenotipo , Antecedentes Genéticos , Ratones de la Cepa 129 , Masculino , Frecuencia Cardíaca/genética , Miocardio/patología , Envejecimiento/genética
5.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38691562

RESUMEN

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Tabique Interventricular , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Tabique Interventricular/diagnóstico por imagen , Anciano de 80 o más Años , Factores de Riesgo , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico por imagen , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/diagnóstico por imagen , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Medición de Riesgo , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Tomografía Computarizada Multidetector , Tomografía Computarizada por Rayos X , Potenciales de Acción
6.
Pacing Clin Electrophysiol ; 47(8): 1049-1053, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38214176

RESUMEN

To date, there have been no reports of recording epicardial electrograms at the onset of spontaneous ventricular fibrillation (VF) in patients with Brugada syndrome (BrS). In the case of BrS, unipolar and bipolar electrogram recording on the right ventricular epicardium revealed that dispersion of repolarization with delayed potential was associated with spontaneous occurrence of VF. Phase 2 reentry associated with shortening and dispersion of action potential could have been recorded for the first time in BrS. Epicardial unipolar mapping can guide accurate and appropriate ablation for the elimination of arrhythmia substrate in J wave syndrome.


Asunto(s)
Síndrome de Brugada , Electrocardiografía , Fibrilación Ventricular , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/complicaciones , Humanos , Fibrilación Ventricular/fisiopatología , Masculino , Sistema de Conducción Cardíaco/fisiopatología , Mapeo Epicárdico , Adulto
7.
Curr Cardiol Rep ; 26(8): 801-814, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38976199

RESUMEN

PURPOSE OF THE REVIEW: Cardiac pacing has evolved in recent years currently culminating in the specific stimulation of the cardiac conduction system (conduction system pacing, CSP). This review aims to provide a comprehensive overview of the available literature on CSP, focusing on a critical classification of studies comparing CSP with standard treatment in the two fields of pacing for bradycardia and cardiac resynchronization therapy in patients with heart failure. The article will also elaborate specific benefits and limitations associated with CSP modalities of His bundle pacing (HBP) and left bundle branch area pacing (LBBAP). RECENT FINDINGS: Based on a growing number of observational studies for different indications of pacing therapy, both CSP modalities investigated are advantageous over standard treatment in terms of narrowing the paced QRS complex and preserving or improving left ventricular systolic function. Less consistent evidence exists with regard to the improvement of heart failure-related rehospitalization rates or mortality, and effect sizes vary between HBP and LBBAP. LBBAP is superior over HBP in terms of lead measurements and procedural duration. With regard to all reported outcomes, evidence from large scale randomized controlled clinical trials (RCT) is still scarce. CSP has the potential to sustainably improve patient care in cardiac pacing therapy if patients are appropriately selected and limitations are considered. With this review, we offer not only a summary of existing data, but also an outlook on probable future developments in the field, as well as a detailed summary of upcoming RCTs that provide insights into how the journey of CSP continues.


Asunto(s)
Bradicardia , Estimulación Cardíaca Artificial , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Estimulación Cardíaca Artificial/métodos , Bradicardia/terapia , Bradicardia/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Fascículo Atrioventricular/fisiopatología , Resultado del Tratamiento
8.
J Electrocardiol ; 85: 7-15, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38810594

RESUMEN

INTRODUCTION: The electrocardiogram (ECG) is a valuable tool for interpreting ventricular repolarization. This article aims to broaden the diagnostic scope beyond the conventional ischemia-centric approach, integrating an understanding of pathophisiological influences on ST-T wave changes. METHODS: A review was conducted on the physiological underpinnings of ventricular repolarization and the pathophisiological processes that can change ECG patterns. The research encompassed primary repolarization abnormalities due to uniform variations in ventricular action potential, secondary changes from electrical or mechanical alterations, and non-ischemic conditions influencing ST-T segments. RESULTS: Primary T waves are characterized by symmetrical waves with broad bases and variable QT intervals, indicative of direct myocardial action potential modifications due to ischemia, electrolyte imbalances, and channelopathies. Secondary T waves are asymmetric and often unassociated with significant QT interval changes, suggesting depolarization alterations or changes in cardiac geometry and contractility. CONCLUSION: We advocate for a unified ECG analysis, recognizing primary and secondary ST-T changes, and their clinical implications. Our proposed analytical framework enhances the clinician's ability to discern a wide array of cardiac conditions, extending diagnostic accuracy beyond myocardial ischemia.


Asunto(s)
Electrocardiografía , Humanos , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico , Sistema de Conducción Cardíaco/fisiopatología , Potenciales de Acción
9.
J Electrocardiol ; 84: 161-164, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38733733

RESUMEN

Since the introduction of left bundle branch pacing (LBBP), a search for precise parameters confirming successful capture of conduction system was conducted. Most of the proposed electrocardiographic criteria refer to patients with narrow QRS complexes. We present a patient with heart failure in whom cardiac resynchronization was achieved using conduction system pacing. While measuring left ventricular activation time, an isoelectric interval of 74 ms between stimulus and R-wave appeared resulting in prolongation of V6 RWPT to 124 ms. Considering the immediate narrowing of QRS complexes following LBBP, the observed latency most probably reflects prolonged conduction time through the His-Purkinje system.


Asunto(s)
Bloqueo de Rama , Electrocardiografía , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Masculino , Terapia de Resincronización Cardíaca/métodos , Fascículo Atrioventricular/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Resultado del Tratamiento , Anciano , Persona de Mediana Edad
10.
Bull Exp Biol Med ; 176(6): 761-766, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38896318

RESUMEN

A number of pharmacological drugs have side effects that contribute to the occurrence of atrial fibrillation, the most common type of cardiac rhythm disorders. The clinical use of antihistamines is widespread; however, information regarding their anti- and/or proarrhythmic effects is contradictory. In this work, we studied the effects and mechanisms of the potential proarrhythmic action of the first-generation antihistamine chloropyramine (Suprastin) in the atrial myocardium and pulmonary vein (PV) myocardial tissue. In PV, chloropyramine caused depolarization of the resting potential and led to reduction of excitation wave conduction. These effects are likely due to suppression of the inward rectifier potassium current (IK1). In presence of epinephrine, chloropyramine induced spontaneous automaticity in the PV and could not be suppressed by atrial pacing. Chloropyramine change functional characteristics of PV and contribute to occurrence of atrial fibrillation. It should be noted that chloropyramine does not provoke atrial tachyarrhythmias, but create conditions for their occurrence during physical exercise and sympathetic stimulation.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Venas Pulmonares/efectos de los fármacos , Venas Pulmonares/fisiopatología , Animales , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/inducido químicamente , Atrios Cardíacos/efectos de los fármacos , Atrios Cardíacos/fisiopatología , Clorfeniramina/farmacología , Epinefrina/farmacología , Antagonistas de los Receptores Histamínicos H1/farmacología , Miocardio/metabolismo , Miocardio/patología , Masculino , Potenciales de Acción/efectos de los fármacos , Sistema de Conducción Cardíaco/efectos de los fármacos , Sistema de Conducción Cardíaco/fisiopatología
11.
Turk J Med Sci ; 53(6): 1799-1806, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38813482

RESUMEN

Background/aim: Despite advancements in valve technology and increased clinical experience, complications related to conduction defects after transcatheter aortic valve implantation (TAVR) have not improved as rapidly as expected. In this study, we aimed to predict the development of complete atrioventricular (AV) block and bundle branch block during and after the TAVR procedure and to investigate any changes in the cardiac conduction system before and after the procedure using electrophysiological study. Materials and methods: A total of 30 patients who were scheduled for TAVR at our cardiovascular council were planned to be included in the study. TAVR was performed on patients at Erciyes University Medical Faculty Hospital as a single center between May 2019 and August 2020 Diagnostic electrophysiological study was performed before the TAVR procedure and after its completion. Changes in the cardiac conduction system during the preprocedure, intra-procedure, and postprocedure periods were recorded. Results: Significant increases in baseline cycle length, atrial-His (AH) interval, his-ventricular (HV) interval and atrioventricular (AV) distance were observed before and after the TAVR procedure (p = 0.039, p < 0.001, p = 0.018, p < 0.001, respectively). During the TAVR procedure, the preprocedural HV interval was longer in patients who developed AV block and bundle branch block compared to those who did not and this difference was statistically significant (p = 0.024). ROC curve analysis revealed that a TAVR preprocedure HV value >59.5 ms had 86% specificity and 75% sensitivity in detecting AV block and bundle branch block (AUC = 0.83, 95% CI: 0.664-0.996, p = 0.013). The preprocedure HV distance was 98 ± 10.55ms in the group with permanent pacemaker implantation and the mean value in the group without permanent pacemaker implantation was 66.27 ± 15.55 ms, showing a borderline significant difference (p = 0.049). Conclusion: The prolongation of HV interval in patients with AV block and bundle branch block suggests that the block predominantly occurs at the infra-hisian level. Patients with longer preprocedural HV intervals should be closely monitored for the need for permanent pacemaker implantation after the TAVR procedure.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Bloqueo de Rama/etiología , Estenosis de la Válvula Aórtica/cirugía , Electrocardiografía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Sistema de Conducción Cardíaco/fisiopatología
12.
Dev Biol ; 478: 163-172, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34245725

RESUMEN

The cardiac conduction system is a network of heterogeneous cell population that initiates and propagates electric excitations in the myocardium. Purkinje fibers, a network of specialized myocardial cells, comprise the distal end of the conduction system in the ventricles. The developmental origins of Purkinje fibers and their roles during cardiac physiology and arrhythmia have been reported. However, it is not clear if they play a role during ischemic injury and heart regeneration. Here we introduce a novel tamoxifen-inducible Cre allele that specifically labels a broad range of components in the cardiac conduction system while excludes other cardiac cell types and vital organs. Using this new allele, we investigated the cellular and molecular response of Purkinje fibers to myocardial injury. In a neonatal mouse myocardial infarction model, we observed significant increase in Purkinje cell number in regenerating myocardium. RNA-Seq analysis using laser-captured Purkinje fibers showed a unique transcriptomic response to myocardial infarction. Our finds suggest a novel role of cardiac Purkinje fibers in heart injury.


Asunto(s)
Sistema de Conducción Cardíaco/fisiología , Integrasas/genética , Infarto del Miocardio/fisiopatología , Ramos Subendocárdicos/fisiología , Alelos , Animales , Animales Recién Nacidos , Linaje de la Célula , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/patología , Ratones , Ratones Transgénicos , Infarto del Miocardio/patología , Miocardio/patología , Miocitos Cardíacos/fisiología , Ramos Subendocárdicos/fisiopatología , RNA-Seq , Regeneración , Tamoxifeno/farmacología , Transcriptoma , Función Ventricular
13.
Circulation ; 143(3): 212-226, 2021 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-33169628

RESUMEN

BACKGROUND: Fast ventricular tachycardias (VTs) have historically been attributed to shorter path lengths with smaller reentrant circuit dimensions in animal models. The relationship between the dimensions of the reentrant VT circuit and tachycardia cycle length (TCL) has not been examined in humans. This study aimed to analyze the determinants of the rate of human VT with comparison of circuit dimensions and conduction velocity (CV) across a wide range of both stable and unstable VTs delineated by high-resolution mapping. METHODS: Fifty-four VTs with complete circuit delineation (>90% TCL) by high-resolution multielectrode mapping were analyzed in 49 patients (men, 88%; age, 65 years [58-71 years]; nonischemic, 47%). Fast VT was defined as TCL <333 milliseconds (rate >180 bpm). Unstable VT was defined by hemodynamic deterioration with an intrinsic mean arterial pressure <60 mm Hg during a sustained episode. RESULTS: The median TCL of VT was 365 milliseconds (306-443 milliseconds), and 24 fast VTs were characterized. A wide range of CVs was observed within the entrance (0.03-0.55 m/s), common pathway (0.03-0.77 m/s), exit (0.03-0.53 m/s), and outer loop (0.17-1.13 m/s). There were no significant differences in the median dimensions of the isthmus and path length between fast and slow VTs and between unstable and stable VTs. The outer loop CV was the only circuit component that correlated with TCL in both ischemic cardiomyopathy (r=-0.5, P=0.006) and nonischemic cardiomyopathy (r=-0.45, P=0.028). The duration of the longest diastolic electrogram was inversely correlated with the dimensions of common pathway (length: r=-0.46, P=0.001, width: r=-0.3, P=0.047) and predictive of rapid VT termination by a single radiofrequency application (r=-0.41, P=0.023). CONCLUSIONS: Because of a wide spectrum of CV observed within the reentrant path during human VT, the dimensions of the circuit were not predictive of VT cycle length. For the first time, we demonstrate that the CV of the outer loop, rather than isthmus, is the principal determinant of the rate of VT. The size of the circuit was similar between fast and slow VTs and between unstable and stable VTs. Long, continuous electrograms were indicative of spatially confined isthmus dimensions, confirmed by rapid termination of VT during radiofrequency delivery.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Anciano , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Taquicardia Ventricular/cirugía
14.
Circ Res ; 127(1): 51-72, 2020 06 19.
Artículo en Inglés | MEDLINE | ID: mdl-32717172

RESUMEN

Atrial fibrillation (AF) is a highly prevalent arrhythmia, with substantial associated morbidity and mortality. There have been significant management advances over the past 2 decades, but the burden of the disease continues to increase and there is certainly plenty of room for improvement in treatment options. A potential key to therapeutic innovation is a better understanding of underlying fundamental mechanisms. This article reviews recent advances in understanding the molecular basis for AF, with a particular emphasis on relating these new insights to opportunities for clinical translation. We first review the evidence relating basic electrophysiological mechanisms to the characteristics of clinical AF. We then discuss the molecular control of factors leading to some of the principal determinants, including abnormalities in impulse conduction (such as tissue fibrosis and other extra-cardiomyocyte alterations, connexin dysregulation and Na+-channel dysfunction), electrical refractoriness, and impulse generation. We then consider the molecular drivers of AF progression, including a range of Ca2+-dependent intracellular processes, microRNA changes, and inflammatory signaling. The concept of key interactome-related nodal points is then evaluated, dealing with systems like those associated with CaMKII (Ca2+/calmodulin-dependent protein kinase-II), NLRP3 (NACHT, LRR, and PYD domains-containing protein-3), and transcription-factors like TBX5 and PitX2c. We conclude with a critical discussion of therapeutic implications, knowledge gaps and future directions, dealing with such aspects as drug repurposing, biologicals, multispecific drugs, the targeting of cardiomyocyte inflammatory signaling and potential considerations in intervening at the level of interactomes and gene-regulation. The area of molecular intervention for AF management presents exciting new opportunities, along with substantial challenges.


Asunto(s)
Fibrilación Atrial/genética , Sistema de Conducción Cardíaco/metabolismo , Animales , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/metabolismo , Fibrilación Atrial/fisiopatología , Sistema de Conducción Cardíaco/fisiología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Canales Iónicos/genética , Canales Iónicos/metabolismo , Investigación Biomédica Traslacional/métodos
15.
PLoS Comput Biol ; 17(2): e1008683, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33591969

RESUMEN

Contemporary accounts of the initiation of cardiac arrhythmias typically rely on after-depolarizations as the trigger for reentrant activity. The after-depolarizations are usually triggered by calcium entry or spontaneous release within the cells of the myocardium or the conduction system. Here we propose an alternative mechanism whereby arrhythmias are triggered autonomously by cardiac cells that fail to repolarize after a normal heartbeat. We investigated the proposal by representing the heart as an excitable medium of FitzHugh-Nagumo cells where a proportion of cells were capable of remaining depolarized indefinitely. As such, those cells exhibit bistable membrane dynamics. We found that heterogeneous media can tolerate a surprisingly large number of bistable cells and still support normal rhythmic activity. Yet there is a critical limit beyond which the medium is persistently arrhythmogenic. Numerical analysis revealed that the critical threshold for arrhythmogenesis depends on both the strength of the coupling between cells and the extent to which the abnormal cells resist repolarization. Moreover, arrhythmogenesis was found to emerge preferentially at tissue boundaries where cells naturally have fewer neighbors to influence their behavior. These findings may explain why atrial fibrillation typically originates from tissue boundaries such as the cuff of the pulmonary vein.


Asunto(s)
Potenciales de Acción , Antiarrítmicos/farmacología , Arritmias Cardíacas/tratamiento farmacológico , Corazón/fisiología , Algoritmos , Animales , Fibrilación Atrial/fisiopatología , Calcio/metabolismo , Progresión de la Enfermedad , Sistema de Conducción Cardíaco/fisiopatología , Células Musculares/citología , Miocitos Cardíacos/metabolismo , Venas Pulmonares/fisiopatología , Conejos
16.
PLoS Comput Biol ; 17(8): e1009233, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34383746

RESUMEN

Mutations are known to cause perturbations in essential functional features of integral membrane proteins, including ion channels. Even restricted or point mutations can result in substantially changed properties of ion currents. The additive effect of these alterations for a specific ion channel can result in significantly changed properties of the action potential (AP). Both AP shortening and AP prolongation can result from known mutations, and the consequences can be life-threatening. Here, we present a computational method for identifying new drugs utilizing combinations of existing drugs. Based on the knowledge of theoretical effects of existing drugs on individual ion currents, our aim is to compute optimal combinations that can 'repair' the mutant AP waveforms so that the baseline AP-properties are restored. More specifically, we compute optimal, combined, drug concentrations such that the waveforms of the transmembrane potential and the cytosolic calcium concentration of the mutant cardiomyocytes (CMs) becomes as similar as possible to their wild type counterparts after the drug has been applied. In order to demonstrate the utility of this method, we address the question of computing an optimal drug for the short QT syndrome type 1 (SQT1). For the SQT1 mutation N588K, there are available data sets that describe the effect of various drugs on the mutated K+ channel. These published findings are the basis for our computational analysis which can identify optimal compounds in the sense that the AP of the mutant CMs resembles essential biomarkers of the wild type CMs. Using recently developed insights regarding electrophysiological properties among myocytes from different species, we compute optimal drug combinations for hiPSC-CMs, rabbit ventricular CMs and adult human ventricular CMs with the SQT1 mutation. Since the 'composition' of ion channels that form the AP is different for the three types of myocytes under consideration, so is the composition of the optimal drug.


Asunto(s)
Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/genética , Canal de Potasio ERG1/efectos de los fármacos , Canal de Potasio ERG1/genética , Sistema de Conducción Cardíaco/anomalías , Cardiopatías Congénitas/tratamiento farmacológico , Cardiopatías Congénitas/genética , Modelos Cardiovasculares , Miocitos Cardíacos/efectos de los fármacos , Potenciales de Acción/efectos de los fármacos , Sustitución de Aminoácidos , Animales , Antiarrítmicos/administración & dosificación , Arritmias Cardíacas/fisiopatología , Biología Computacional , Combinación de Medicamentos , Diseño de Fármacos , Quimioterapia Combinada/métodos , Canal de Potasio ERG1/fisiología , Sistema de Conducción Cardíaco/fisiopatología , Cardiopatías Congénitas/fisiopatología , Humanos , Células Madre Pluripotentes Inducidas/efectos de los fármacos , Células Madre Pluripotentes Inducidas/fisiología , Mutación Missense , Miocitos Cardíacos/fisiología , Conejos
17.
PLoS Comput Biol ; 17(2): e1008089, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33591962

RESUMEN

Short QT (SQT) syndrome is a genetic cardiac disorder characterized by an abbreviated QT interval of the patient's electrocardiogram. The syndrome is associated with increased risk of arrhythmia and sudden cardiac death and can arise from a number of ion channel mutations. Cardiomyocytes derived from induced pluripotent stem cells generated from SQT patients (SQT hiPSC-CMs) provide promising platforms for testing pharmacological treatments directly in human cardiac cells exhibiting mutations specific for the syndrome. However, a difficulty is posed by the relative immaturity of hiPSC-CMs, with the possibility that drug effects observed in SQT hiPSC-CMs could be very different from the corresponding drug effect in vivo. In this paper, we apply a multistep computational procedure for translating measured drug effects from these cells to human QT response. This process first detects drug effects on individual ion channels based on measurements of SQT hiPSC-CMs and then uses these results to estimate the drug effects on ventricular action potentials and QT intervals of adult SQT patients. We find that the procedure is able to identify IC50 values in line with measured values for the four drugs quinidine, ivabradine, ajmaline and mexiletine. In addition, the predicted effect of quinidine on the adult QT interval is in good agreement with measured effects of quinidine for adult patients. Consequently, the computational procedure appears to be a useful tool for helping predicting adult drug responses from pure in vitro measurements of patient derived cell lines.


Asunto(s)
Antiarrítmicos/farmacología , Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/fisiopatología , Evaluación Preclínica de Medicamentos/métodos , Sistema de Conducción Cardíaco/anomalías , Cardiopatías Congénitas/tratamiento farmacológico , Cardiopatías Congénitas/fisiopatología , Modelos Cardiovasculares , Miocitos Cardíacos/efectos de los fármacos , Miocitos Cardíacos/fisiología , Potenciales de Acción/efectos de los fármacos , Adulto , Ajmalina/farmacología , Algoritmos , Arritmias Cardíacas/genética , Línea Celular , Biología Computacional , Evaluación Preclínica de Medicamentos/estadística & datos numéricos , Canal de Potasio ERG1/genética , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Cardiopatías Congénitas/genética , Humanos , Técnicas In Vitro , Células Madre Pluripotentes Inducidas/efectos de los fármacos , Células Madre Pluripotentes Inducidas/fisiología , Ivabradina/farmacología , Mexiletine/farmacología , Mutación , Quinidina/farmacología , Investigación Biomédica Traslacional
18.
BMC Cardiovasc Disord ; 22(1): 52, 2022 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-35172723

RESUMEN

BACKGROUND: QT interval as an indicator of ventricular repolarization is a clinically important parameter on an electrocardiogram (ECG). QT prolongation predisposes individuals to different ventricular arrhythmias and sudden cardiac death. The current study aimed to identify the best heart rate corrected QT interval for a non-hospitalized Iranian population based on cardiovascular mortality. METHODS: Using Fasa PERSIAN cohort study data, this study enrolled 7071 subjects aged 35-70 years. Corrected QT intervals (QTc) were calculated by the QT interval measured by Cardiax® software from ECGs and 6 different correction formulas (Bazett, Fridericia, Dmitrienko, Framingham, Hodges, and Rautaharju). Mortality status was checked using an annual telephone-based follow-up and a minimum 3-year follow-up for each participant. Bland-Altman, QTc/RR regression, sensitivity analysis, and Cox regression were performed in IBM SPSS Statistics v23 to find the best QT. Also, for calculating the upper and lower limits of normal of different QT correction formulas, 3952 healthy subjects were selected. RESULTS: In this study, 56.4% of participants were female, and the mean age was 48.60 ± 9.35 years. Age, heart rate in females, and QT interval in males were significantly higher. The smallest slopes of QTc/RR analysis were related to Fridericia in males and Rautaharju followed by Fridericia in females. Thus, Fridericia's formula was identified as the best mathematical formula and Bazett's as the worst in males. In the sensitivity analysis, however, Bazett's formula had the highest sensitivity (23.07%) among all others in cardiac mortality. Also, in the Cox regression analysis, Bazett's formula was better than Fridericia's and was identified as the best significant cardiac mortality predictor (Hazard ratio: 4.31, 95% CI 1.73-10.74, p value = 0.002). CONCLUSION: Fridericia was the best correction formula based on mathematical methods. Bazett's formula despite its poorest performance in mathematical methods, was the best one for cardiac mortality prediction. Practically, it is suggested that physicians use QTcB for a better evaluation of cardiac mortality risk. However, in population-based studies, QTcFri might be the one to be used by researchers.


Asunto(s)
Potenciales de Acción , Arritmias Cardíacas/diagnóstico , Electrocardiografía , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Modelos Cardiovasculares , Procesamiento de Señales Asistido por Computador , Adulto , Anciano , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Femenino , Humanos , Irán , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
19.
BMC Cardiovasc Disord ; 22(1): 14, 2022 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-35067224

RESUMEN

PURPOSE: The purpose of this study was to investigate the safety and efficacy of high-power short-duration (HP-SD) ablation compared to conventional ablation in patients with atrial fibrillation (AF). METHODS: We enrolled consecutive 158 drug-refractory symptomatic AF patients (119 males, mean age 63 ± 10 years) who had undergone first radiofrequency pulmonary vein isolation (PVI). PVI was performed using the conventional setting (20-35 W) in 73 patients (Conventional group) and using the HP-SD setting (45-50 W) in 85 patients (HP-SD group). The rate of first pass isolation, remaining gaps after circumferential ablation, dormant conduction, and the radiofrequency application time in each pulmonary vein (PV) were compared between the groups. RESULTS: The first pass isolation ratio was significantly higher in the HP-SD group than in the Conventional group (81% vs. 65%, P = 0.027) in the right PV, but did not differ in the left PV. The remaining gaps were fewer in the right superior PV (4% vs. 21%, P = 0.001) and left inferior PV (1% vs. 8%, P = 0.032) areas, and the radiofrequency application time in each PV was shorter (right PV, 12.0 ± 8.9 min vs. 34.0 ± 31.7 min, P < 0.001; left PV, 10.6 ± 3.6 min vs. 25.7 ± 22.3 min, P < 0.001) in the HP-SD group than in the Conventional group. CONCLUSION: The use of the HP-SD setting might contribute to improve the first pass isolation rate and to shorten the radiofrequency application time in each PV.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca/fisiología , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
20.
J Mol Cell Cardiol ; 158: 72-81, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34048725

RESUMEN

BACKGROUND: Both gap junctional remodeling and interstitial fibrosis have been linked to impaired electrical conduction velocity (CV) and fatal ventricular arrhythmias in nonischemic heart failure (HF). However, the arrhythmogenic role of the ventricular gap junctional Cx43 in nonischemic HF remains in debate. Here, we assessed this in a newly developed arrhythmogenic canine model of nonischemic HF. METHODS AND RESULTS: Nonischemic HF was induced in canines by combined aortic valve insufficiency and aortic constriction. Left ventricular (LV) myocardium from HF dogs showed similar pathological changes to that of humans. HF dogs had reduced LV function, widened QRS complexes, and spontaneous nonsustained ventricular tachycardia. CV was measured in intact LV epicardium with high-density grid mapping. Total (Cx43-T) and nonphosphorylated Cx43 (Cx43-NP) and histological interstitial fibrosis were assessed from these mapped LV tissues. Longitudinal CV, which was slowed in HF (49 ± 1 vs. 65 ± 2 cm/s in Ctl), was positively correlated with reduced total junctional Cx43 and negatively correlated with markedly increased junctional Cx43-NP (2-fold) in HF. Cx43 dephosphorylation in HF was associated with enhanced colocalization of PP2A at the level of Cx43. Unchanged action potential upstroke and transverse CV were associated with unaltered Cx43 lateralization and interstitial fibrosis in the nonischemic HF canine LV. CONCLUSION: Our unique arrhythmogenic canine model of HF resembles human nonischemic HF (prior to the end stage). Cx43 remodeling occurs prior to the structural remodeling (with lack of fibrosis) in HF and it is crucial in slowed CV and ventricular arrhythmia development. Our findings suggest that altered Cx43 alone is arrhythmogenic and modulation of Cx43 has the anti-arrhythmic therapeutic potential for HF patients.


Asunto(s)
Conexina 43/metabolismo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/metabolismo , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/metabolismo , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/metabolismo , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/metabolismo , Potenciales de Acción , Animales , Modelos Animales de Enfermedad , Perros , Conductividad Eléctrica , Femenino , Fibrosis , Uniones Comunicantes/metabolismo , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/metabolismo , Ventrículos Cardíacos/patología , Masculino , Fosforilación , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA