1.
AAPS PharmSciTech ; 22(4): 151, 2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-33977355

RESUMEN

As commonly known, the product development stage is quite complex, requires intensive knowledge, and is time-consuming. The selection of the excipients with the proper functionality and their corresponding levels is critical to drug product performance. The objective of this study was to apply quality by design (QbD) principles for formulation development and to define the desired product quality profile (QTPP) and critical quality attributes (CQA) of a product. QbD is a risk- and science-based holistic approach for upgraded pharmaceutical development. In this study, Ibuprofen DC 85W was used as a model drug, Cellactose® 80 along with MicroceLac® 100 as a filler, and magnesium stearate, stearic acid, and sodium stearyl fumarate as lubricants. By applying different formulation parameters to the filler and lubricants, the QbD approach furthers the understanding of the effect of critical formulation and process parameters on CQAs and the contribution to the overall quality of the drug product. An experimental design study was conducted to determine the changes of the obtained outputs of the formulations, which were evaluated using the Modde Pro 12.1 statistical computer program that enables optimization by modeling complex relationships. The results of the optimum formulation revealed that MicroceLac® 100 was the superior filler, while magnesium stearate at 1% was the optimum lubricant. A design space that indicates the safety operation limits for the process and formulation variables was also created. This study enriches the understanding of the effect of excipients in formulation and assists in enhancing formulation design using experimental design and mathematical modeling methods in the frame of the QbD approach.


Asunto(s)
Química Farmacéutica/métodos , Fuerza Compresiva , Desarrollo de Medicamentos/métodos , Lubricantes/síntesis química , Química Farmacéutica/normas , Composición de Medicamentos/métodos , Desarrollo de Medicamentos/normas , Ibuprofeno/síntesis química , Ibuprofeno/normas , Lubricantes/normas , Ácidos Esteáricos/síntesis química , Ácidos Esteáricos/normas , Tensoactivos/síntesis química , Tensoactivos/normas , Comprimidos , Resistencia a la Tracción
2.
Regul Toxicol Pharmacol ; 108: 104452, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31487490

RESUMEN

Perfluorohexane sulfonate (PFHxS) is a six-carbon perfluoroalkyl sulfonic acid that was used as an industrial surfactant, but is now found as an environmental contaminant worldwide. In addition to its use as an industrial surfactant, it is a legacy contaminant from the use of aqueous film-forming foams. Despite its widespread occurrence in the environment and evidence of biological activity associated with PFHxS and similar perfluoroalkyl sulfonic acids in rodents, there is no oral toxicity value currently available from the IRIS Database. To derive an oral reference dose (RfD) for PFHxS, available toxicity studies were reviewed using a weight-of-evidence approach. A 42-day mouse reproductive study was chosen as the critical study for the derivation of the oral RfD. Benchmark dose modeling was utilized to derive a point of departure (POD) for a reduction in litter size. A 95% lower confidence limit on the benchmark dose (BMDL) of 13,900 ng/mL (serum PFHxS) was modeled for a reduction in litter size. An oral RfD for PFHxS of 4.0 ng/kg/d was calculated by conversion of the BMDL to a human equivalent oral dose using a human half-life adjusted dosimetric conversion factor and the application of a total uncertainty factor of 300. Additional research is needed to better characterize the toxicity associated with oral exposure to PFHxS and refine the development of toxicity values.


Asunto(s)
Ácidos Sulfónicos/normas , Tensoactivos/normas , Administración Oral , Animales , Fluorocarburos , Humanos , Tamaño de la Camada/efectos de los fármacos , Concentración Máxima Admisible , Ratones , Reproducción/efectos de los fármacos , Medición de Riesgo , Ácidos Sulfónicos/farmacocinética , Ácidos Sulfónicos/toxicidad , Tensoactivos/farmacocinética , Tensoactivos/toxicidad
3.
Z Geburtshilfe Neonatol ; 220(1): 9-15, 2016 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-26866689

RESUMEN

Natural fibres (bulk-forming agents), docusate sodium (stool-softener), mineral oils (lubricant laxatives), macrogol (polyethylene glycol, PEG), sugars and sugar alcohols (osmotic laxatives) and anthraquinones and diphenolic laxatives (stimulant laxatives) seem to be safe medicaments regarding teratogenicity and lactation. The US Food and Drug Administration (FDA) risk categories for these substances taken during pregnancy and lactation are often the result of the lack of studies than of evidence-based information. So risk categories do not help in the decision-making for the right laxative. Alternative solutions such as proposals of the American College of Gastroenterology's Committee on FDA related matters, (ACG-FDA) and the Motherisk Programme try to improve decision-making. For newer compounds such as chloride-channel-activators and procinetics no data regarding safe use in pregnancy and during breast-feeding are available as yet. We suggest the use of macrogol and lactulose as the first-line therapy in treating chronic constipation during pregnancy. Macrogol shows some advantages, such as faster onset of bowel action and fewer flatulences. If this treatment does not work or starts but then stops working, we recommend in the second and third trimenon a second-line treatment with diphenolic laxatives such as bisacodyl and and sodium picosulfate. During pregnancy the decision on the application of these laxatives is largely determined by the side-effects of tenesmus associated with preterm births. During lactation we recommend macrogol (preferable to lactulose due to the lack of data), lactulose, bisacodyl and sodium picosulfate, according to the nature of the conditions.


Asunto(s)
Catárticos/administración & dosificación , Estreñimiento/terapia , Lactancia/efectos de los fármacos , Laxativos/administración & dosificación , Guías de Práctica Clínica como Asunto , Complicaciones del Embarazo/terapia , Lactancia Materna , Catárticos/normas , Estreñimiento/diagnóstico por imagen , Femenino , Alemania , Humanos , Recién Nacido , Laxativos/normas , Obstetricia/normas , Embarazo , Complicaciones del Embarazo/diagnóstico , Tensoactivos/administración & dosificación , Tensoactivos/normas
4.
AAPS PharmSciTech ; 12(2): 468-75, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21479751

RESUMEN

A series of amphiphilic ion pairs of erythromycin (ERY) with lipoamino acids (LAAs) were produced. The ion pairs were prepared by evaporation of a water/ethanol co-solution of the drug and LAA bearing an alkyl side chain of 10-16 carbon atoms. For the sake of comparison, equimolar physical mixtures were prepared by triturating ERY and the LAA in the absence of any solvent. FTIR spectroscopy confirmed the structure of ion pairs, while differential scanning calorimetry and powder X-ray diffractometry were used to assess the formation of new saline species. The solubility pattern of the coevaporates in different aqueous and organic solvents confirmed their amphiphilic properties. ERY-LAA ion pairs were submitted to an in vitro microbiological assay against different bacterial strains, both susceptible and resistant to macrolides. The presence of the LAA moiety was shown not altering the antibacterial spectrum of activity of the drug. These results can be the basis for a further evaluation of ERY-LAA ion pairs as a mean to improve the penetration of the drug inside bacterial cells and to optimize the loading of ERY in lipid-based nanocarriers.


Asunto(s)
Aminoácidos/química , Antibacterianos/química , Eritromicina/química , Tensoactivos/química , Aminoácidos/farmacología , Aminoácidos/normas , Antibacterianos/farmacología , Antibacterianos/normas , Evaluación Preclínica de Medicamentos/métodos , Evaluación Preclínica de Medicamentos/normas , Eritromicina/farmacología , Eritromicina/normas , Lípidos/química , Lípidos/farmacología , Lípidos/normas , Pruebas de Sensibilidad Microbiana/métodos , Pruebas de Sensibilidad Microbiana/normas , Staphylococcus aureus/efectos de los fármacos , Tensoactivos/farmacología , Tensoactivos/normas
5.
Drug Dev Ind Pharm ; 36(12): 1486-96, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20545515

RESUMEN

OBJECTIVE: The objective of this study was to investigate the effects of sodium lauryl sulfate (SLS) from different sources on solubilization/wetting, granulation process, and tablet dissolution of BILR 355 and the potential causes. METHODS: The particle size distribution, morphology, and thermal behaviors of two pharmaceutical grades of SLS from Spectrum and Cognis were characterized. The surface tension and drug solubility in SLS solutions were measured. The BILR 355 tablets were prepared by a wet granulation process and the dissolution was evaluated. RESULTS: The critical micelle concentration was lower for Spectrum SLS, which resulted in a higher BILR 355 solubility. During wet granulation, less water was required to reach the same end point using Spectrum than Cognis SLS. In general, BILR 355 tablets prepared with Spectrum SLS showed a higher dissolution than the tablets containing Cognis SLS. Micronization of SLS achieved the same improved tablet dissolution as micronized active pharmaceutical ingredient. CONCLUSIONS: The observed differences in wetting and solubilization were likely due to the different impurity levels in SLS from two sources. This study demonstrated that SLS from different sources could have significant impact on wet granulation process and dissolution. Therefore, it is critical to evaluate SLS properties from different suppliers, and then identify optimal formulation and process parameters to ensure robustness of drug product manufacture process and performance.


Asunto(s)
Azepinas/química , Piridinas/química , Inhibidores de la Transcriptasa Inversa/química , Dodecil Sulfato de Sodio/química , Tensoactivos/química , Química Farmacéutica , Micelas , Tamaño de la Partícula , Dodecil Sulfato de Sodio/normas , Solubilidad , Tensión Superficial , Tensoactivos/normas , Comprimidos
6.
Mar Pollut Bull ; 129(2): 609-614, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29102073

RESUMEN

The UK Marine Management Organisation (MMO) tasked the Centre for Environment, Fisheries & Aquaculture Science (Cefas) with reviewing the current UK dispersant efficacy testing procedures. The aim was to identify possibilities to increase standardisation, improve health and safety performance and explore harmonisation possibilities with international dispersant efficacy testing procedures. The US EPA 'Baffled Flask Test' (BFT) was adopted, implemented and validated as a new standard method in the UK. The outputs from this study suggest that dispersant efficacy results from the adopted BFT test and the currently used protocol are in a similar range and results presented by the US EPA. As a result, the transition to the adopted BFT test will require minimal changes in the assessment of the results or reporting and increase harmonisation between tests used in the UK and North America.


Asunto(s)
Restauración y Remediación Ambiental/métodos , Contaminación por Petróleo/análisis , Petróleo/análisis , Tensoactivos/química , Contaminantes Químicos del Agua/análisis , Restauración y Remediación Ambiental/normas , Modelos Teóricos , Tensoactivos/normas , Reino Unido
7.
J Hazard Mater ; 140(1-2): 230-6, 2007 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-16987601

RESUMEN

Removal of hydrophobic organic contaminants (HOCs) using surfactant-enhanced electrokinetic (EK) method was studied in a model system. Kaolinite and phenanthrene were selected as a model clay soil and a representative HOC, respectively. Three different types of surfactants: APG (alkyl polyglucoside), Brij30 (polyoxyethylene-4-lauryl ether), and SDS (sodium dodecyl sulfate), were used to enhance the solubility of HOC. Characteristics of surfactants, such as surface tension, HOC solubility, and biodegradability were measured. In the case of Brij30 solution, phenanthrene solubility was higher than that of others. After 4 days, APG and Brij30 were degraded by 65% and 26% of the initial amount, respectively. However, degradation of SDS was hardly detected. Electroosmotic flow (EOF) of Brij30 solution was lower than others when the 0.1M NaCl was used as electrolyte. Addition of the acetate buffer solution increased the EOF of Brij30 solution and enhanced removal of phenanthrene. Among three different surfactants tested, APG showed the highest removal efficiency.


Asunto(s)
Electroósmosis/métodos , Caolín/aislamiento & purificación , Fenantrenos/aislamiento & purificación , Tensoactivos/química , Glucanos , Polidocanol , Polietilenglicoles , Dodecil Sulfato de Sodio , Suelo , Solubilidad , Tensoactivos/normas
8.
J Pharm Sci ; 106(4): 1136-1142, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28057545

RESUMEN

Previously, our group employed the internal phase separation method to produce aqueous core-PLGA [poly(d,l-lactide-co-glycolide)] shell microcapsules with polynuclear core morphologies. This report describes the preparation of the more desired and challenging architecture with mononuclear cores. Optimization of formulation parameters including (1) varying the composition of the internal phase and (2) incorporating selected organic solvents (dichloromethane, chloroform, methanol, and acetonitrile) into the internal phase was systematically evaluated. Varying the composition of the internal phase (i.e., PLGA and water levels) failed to produce mononuclear microcapsules. However, incorporating methanol or acetonitrile into the internal phase produced microcapsules with mononuclear cores as confirmed by phase-contrast microscopy, transmission electron microscopy, and scanning electron microscopy. Stability of the prepared emulsions (internal phase of PLGA, acetone, acetonitrile, and water) was optimized by evaluating different types of surfactants with varying concentrations. Among them, lecithin in the range of 0.5%-5% wt/wt provided the best emulsion stability. Interestingly, increasing lecithin concentrations led to the production of microcapsules with smaller sizes (from 2.4 ± 1.6 to 1.1 ± 0.8 µm) and higher percentage of mononuclear cores. The resulting aqueous core-PLGA shell microcapsules are expected to have interesting applications in drug delivery systems with controlled release for hydrophilic drugs and proteins.


Asunto(s)
Química Farmacéutica/métodos , Ácido Láctico/síntesis química , Microesferas , Ácido Poliglicólico/síntesis química , Agua/química , Química Farmacéutica/normas , Composición de Medicamentos , Emulsiones/síntesis química , Emulsiones/normas , Ácido Láctico/normas , Ácido Poliglicólico/normas , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Tensoactivos/síntesis química , Tensoactivos/normas , Agua/normas
9.
Anal Sci ; 22(1): 147-51, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16429792

RESUMEN

Simple sequential injection analysis systems with DSTD (SIA/DSTD) have been developed. One was employed for the study of the effects of the ion contents in solutions to the dynamic surface pressure of ionic surfactants. The results from the studies show the possibility for an alternative simple fast screening, but also a sensitive procedure for water quality determination. Another simple SIA/DSTD system has been demonstrated for the quantification of an anionic surfactant using a single standard calibration.


Asunto(s)
Tensoactivos/análisis , Calibración , Análisis de Inyección de Flujo/instrumentación , Análisis de Inyección de Flujo/métodos , Sensibilidad y Especificidad , Tensión Superficial , Tensoactivos/normas , Factores de Tiempo , Agua/química
10.
J Hosp Infect ; 59(3): 229-34, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15694980

RESUMEN

This study involved observation of hand-hygiene behaviour and evaluation of the effect of alcohol-based hand disinfection and handwashing with plain liquid soap on microbial flora. The study was performed in a combined medical and surgical intensive care unit. We demonstrated a crude compliance of hand hygiene of 50.4%, which was only performed adequately in 20.8% of cases. Of this group, handwashing and hand-disinfection procedures were performed properly 34.0% and 71.6% of the time, respectively. Hand samples for bacteriological examinations with the glove juice method demonstrated that whilst handwashing was sensitive to the way in which hand hygiene was performed, alcohol-based hand disinfection was less sensitive to such performance. Our study demonstrated that alcohol-based hand disinfection is a robust hand-hygiene method with many advantages in a practical setting. It is very feasible for use in hospital wards.


Asunto(s)
Alcoholes/administración & dosificación , Infección Hospitalaria/prevención & control , Adhesión a Directriz , Desinfección de las Manos/métodos , Unidades de Cuidados Intensivos/normas , Guías de Práctica Clínica como Asunto , Jabones/administración & dosificación , Tensoactivos/administración & dosificación , Adulto , Alcoholes/normas , Infección Hospitalaria/microbiología , Desinfección de las Manos/normas , Hospitales Universitarios , Humanos , Control de Infecciones/métodos , Noruega , Personal de Hospital , Jabones/normas , Tensoactivos/normas
11.
Eur J Pharm Biopharm ; 94: 569-74, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25460583

RESUMEN

The fatty acid (FA) composition of polysorbate 80 (PS80), a sorbitan oleic acid ester copolymerized with about 20mole of ethylene oxide, is typically characterized by gas chromatography. Here, an alternative method was developed. After saponification with potassium hydroxide the FA fraction was collected with liquid-liquid extraction using methyl-tert-butyl ether. HPLC in combination with a Corona® charged aerosol detector (CAD) was applied for the separation and detection. The method was fully validated in terms of specificity, repeatability, limits of quantification, linearity, range, accuracy and robustness. The characterization of 16 different PS80 batches demonstrated variability regarding their FA composition, with e.g. the amount of oleic acid ranging from 67.8±0.7% to 96.6±1.4%. Furthermore, we identified petroselinic acid, a double-bond positional isomer to oleic acid in all batches, an FA not known to pharmacopoeias at present. In addition, 11-hydroxy-9-octadecenoic acid, an oxidation product of oleic acid was identified. Structure elucidation was performed by means of HPLC-MS/MS. In addition, the method was expanded to the evaluation of the free FAs. Having determined the entire FA composition, the acid value according to EP and USP can be calculated.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Ácidos Grasos/análisis , Polisorbatos/química , Tensoactivos/química , Tecnología Farmacéutica/métodos , Aerosoles , Ácidos Grasos/química , Límite de Detección , Extracción Líquido-Líquido , Polisorbatos/normas , Reproducibilidad de los Resultados , Tensoactivos/normas , Espectrometría de Masas en Tándem , Tecnología Farmacéutica/instrumentación
12.
Am J Trop Med Hyg ; 50(4 Suppl): 52-8, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-8172332

RESUMEN

Protection against virulent challenge with murine Plasmodium yoelii malaria was induced by immunization with whole killed blood-stage parasites in copolymer P1004 and detoxified lipopolysaccharide as adjuvant. Similar immunization with Freund's complete adjuvant and other water-in-oil emulsions failed to protect. Protection was associated with the production of antibody of the IgG2a isotype against epitopes measured by immunofluorescence. Several formulations that did not protect elicited high antibody titers measured by enzyme-linked immunosorbent assays or titers of other isotypes measured by indirect immunofluorescent assay. The results provide additional evidence that the adjuvants influenced both the isotype and specificity of antibody. The implications of these findings for vaccine development are discussed.


Asunto(s)
Adyuvantes Inmunológicos , Vacunas contra la Malaria , Malaria/prevención & control , Plasmodium falciparum/inmunología , Poloxaleno , Polímeros , Adyuvantes Inmunológicos/normas , Adyuvantes Inmunológicos/toxicidad , Animales , Anticuerpos Antiprotozoarios/biosíntesis , Especificidad de Anticuerpos , Humanos , Macaca mulatta , Ratones , Plasmodium yoelii/inmunología , Polímeros/normas , Polímeros/toxicidad , Vacunas Antiprotozoos , Tensoactivos/normas , Tensoactivos/toxicidad
13.
J Hosp Infect ; 10(3): 229-35, 1987 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-2891749

RESUMEN

Nosocomial infections on eight acute care nursing units in a tertiary care hospital was compared between two 3-month periods in which floors were cleaned with either disinfectant or detergent. Personnel performing infection surveillance were unaware of the cleaning product used. Surface cultures from selected floor sites were obtained at 3 and 6 months to assess microbial contamination. The combined nosocomial infection rate for the eight wards did not differ between disinfectant (8.0/100 patient discharges) and detergent (7.1/100). For individual wards, a significant difference in nosocomial infection rate between the two periods was observed in only one ward, favouring the detergent. No differences in floor contamination were observed.


Asunto(s)
Infección Hospitalaria/prevención & control , Detergentes/normas , Desinfectantes/normas , Servicio de Limpieza en Hospital/métodos , Tensoactivos/normas , Alberta , Bacterias/aislamiento & purificación , Estudios de Evaluación como Asunto , Pisos y Cubiertas de Piso , Hospitales con más de 500 Camas , Humanos
14.
J Pharm Sci ; 86(3): 384-8, 1997 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9050810

RESUMEN

The intrinsic dissolution rate and solubility of carbamazepine was measured in aqueous solutions of sodium lauryl sulfate (SLS) prepared with two different grades of purity, 95 and 99%, and 95% SLS in 0.15 M NaCl to determine the effect of surface-active impurities and electrolytes. Four significant observations resulted from this work: (1) the equilibrium coefficients calculated from the solubility experiments in the 99% SLS, 95% SLS, and 95% with 0.15 M NaCl SLS solutions were 295, 265, and 233 L/mol, respectively; (2) the dissolution rate enhancement in the 99% SLS was 10% greater than that in the 95% SLS and 95% with 0.15 M NaCl solutions, which were not significantly different; (3) the diffusion coefficients of the drug-loaded micelles estimated from the dissolution experiments were 8.4 x 10(-7) cm2/s for the 99% SLS, 9.5 x 10(-7) cm2/s for the 95% SLS, and 1.2 x 10(-6) cm2/s for the 95% with 0.15 M NaCl; and (4) the critical micelle concentrations for the 99% SLS, 95% SLS, and 95% SLS with 0.15M NaCl were 6.8, 4.2, and 0.35 mM, respectively. The results of this study clearly illustrate the sensitivity of the micelle to impurities and electrolytes with regard to size and loading capacity and the effect these changes have on the solubility and dissolution rate. Therefore, when using surfactants in dissolution media for in vitro testing of dosage forms, consideration must be given to the level of impurities present so that the results are consistent and reliable. Intrinsic dissolution rate, surface tension, or solubility measurements may be useful, convenient methods for identifying changes in the surfactant due to either degradation or lot-to-lot variability.


Asunto(s)
Carbamazepina/química , Cloruro de Sodio/química , Dodecil Sulfato de Sodio/química , Tensoactivos/química , Dodecanol , Micelas , Dodecil Sulfato de Sodio/normas , Solubilidad , Tensión Superficial , Tensoactivos/normas
15.
Food Chem Toxicol ; 36(3): 209-31, 1998 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9609394

RESUMEN

The third phase in a series of investigations of the relationship between low volume eye test (LVET) data, Draize eye irritation test data, and comparable data from in vitro assay protocols is presented. These investigations utilize Draize eye test and in vitro endpoint data generated previously as part of the CTFA Evaluation of Alternatives Program. LVET data were generated de novo using the same 25 representative surfactant-based personal-care formulations. In general, these formulations were minimally to moderately irritating. The linear correlation between maximum average score as determined by the Draize test (MAS) and the LVET (LVET-MAS) was 0.87; LVET-MAS values were typically about 30% lower then corresponding MAS values. Comparison of in vitro assay performance with that of the LVET was determined by statistical analysis of the relationship between LVET-MAS and in vitro endpoint. Regression modelling was the primary means of enabling such a comparison, the objective being to predict LVET-MAS for a given test material (and to place upper and lower prediction bounds on the range in which the LVET-MAS is anticipated to fall with high probability) based on observation of an in vitro score for that material. The degree of 95% confidence in prediction is quantified in terms of the relative widths of prediction intervals constructed about the fitted regression curves. Twenty in vitro endpoints were shown to have the greatest agreement with the LVET (these endpoints included those with low discordance rates relative to the Draize test) and were therefore selected for regression modelling. Although prediction interval widths tended to be narrower when predicting LVET-MAS compared with predicting MAS, the confidence with which the selected in vitro endpoints predicted both LVET-MAS and MAS for surfactant-based formulations was greatest when values were close to the lower or upper limits of the observed irritation range (i.e. 95% prediction interval widths were most narrow in these areas). Overall precision of LVET-MAS prediction for surfactant-based formulations was similar to that previously reported for hydroalcoholic formulations and considerably better than was reported for oil/water emulsions.


Asunto(s)
Alternativas a las Pruebas en Animales , Cosméticos/toxicidad , Ojo/efectos de los fármacos , Irritantes/toxicidad , Soluciones Oftálmicas/toxicidad , Tensoactivos/toxicidad , Pruebas de Toxicidad/métodos , Alcoholes , Animales , Química Farmacéutica , Cosméticos/normas , Emulsiones , Técnicas In Vitro , Aceites , Soluciones Oftálmicas/normas , Conejos , Análisis de Regresión , Tensoactivos/normas , Agua
16.
Environ Toxicol Chem ; 30(8): 1943-54, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21590796

RESUMEN

The European Union's REACH regulation has further highlighted the lack of ecotoxicological data for substances in the marketplace. The mandates under REACH (registration, evaluation, authorization, and restriction of chemicals) to produce data and minimize testing on vertebrates present an impetus for advanced hazard assessment techniques using read-across. Research in our group has recently focused on probabilistic ecotoxicological hazard assessment approaches using chemical toxicity distributions (CTDs). Using available data for chemicals with similar modes of action or within a chemical class may allow for selection of a screening point value (SPV) for development of environmental safety values, based on a probabilistic distribution of toxicity values for a specific endpoint in an ecological receptor. Ecotoxicity data for acetylcholinesterase inhibitors and surfactants in Daphnia magna and Pimephales promelas were gathered from several data sources, including the U.S. Environmental Protection Agency's ECOTOX and Pesticides Ecotoxicity databases, the peer-reviewed literature, and the Human and Environmental Risk Assessment (HERA) project. Chemical toxicity distributions were subsequently developed, and the first and fifth centiles were used as SPVs for the development of screening-predicted no-effect concentrations (sPNECs). The first and fifth centiles of these distributions were divided by an assessment factor of 1,000, as recommended by REACH guidance. Use of screening values created using these techniques could support the processes of data dossier development and environmental exposure assessment, allowing for rigorous prioritization in testing and monitoring to fill data gaps.


Asunto(s)
Ecotoxicología/métodos , Pruebas de Toxicidad/métodos , Animales , Inhibidores de la Colinesterasa/normas , Inhibidores de la Colinesterasa/toxicidad , Cyprinidae , Daphnia , Ecotoxicología/legislación & jurisprudencia , Política Ambiental , Contaminantes Ambientales/normas , Contaminantes Ambientales/toxicidad , Contaminación Ambiental/legislación & jurisprudencia , Contaminación Ambiental/estadística & datos numéricos , Unión Europea , Humanos , Plaguicidas/normas , Plaguicidas/toxicidad , Medición de Riesgo/métodos , Tensoactivos/normas , Tensoactivos/toxicidad , Pruebas de Toxicidad/normas , Estados Unidos , United States Environmental Protection Agency
20.
Mar Pollut Bull ; 58(12): 1903-8, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19692099

RESUMEN

As defined by the National Oil and Hazardous Substances Pollution Contingency Plan (NCP), a surface washing agent (SWA) is a product that removes oil from solid surfaces, such as beaches, rocks, and concrete, through a detergency mechanism and that does not involve dispersing or solubilizing the oil into the water column. Commercial products require testing to qualify for listing on the NCP Product Schedule. Such testing is conducted both for toxicity and effectiveness. Protocols currently exist for bioremediation agents and dispersants, but not SWAs. The US Environmental Protection Agency (EPA) is developing a laboratory testing protocol to evaluate the effectiveness of SWAs in removing crude oil from a solid substrate. This paper summarizes some of the defining research supporting this new protocol. Multiple variables were tested to determine their effect on SWA performance. The protocol was most sensitive to SWA-to-oil ratio and rotational speed of mixing. Less sensitive variables were contact time, mixing time, and SWA concentration when total applied mass of active product was constant. EPA recommendations for the testing protocol will be made following round robin testing.


Asunto(s)
Liberación de Peligros Químicos , Restauración y Remediación Ambiental/normas , Petróleo/análisis , Tensoactivos/normas , Contaminantes Químicos del Agua/análisis , Solventes/análisis , Tensoactivos/química