Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.450
Filtrar
Más filtros

Intervalo de año de publicación
1.
Ann Surg ; 279(5): 746-754, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37991178

RESUMEN

OBJECTIVE: Assess the effectiveness of sacral neuromodulation (SNM) versus personalized conservative treatment (PCT) in patients with refractory idiopathic slow-transit constipation (STC). BACKGROUND: Evidence on SNM for idiopathic STC is conflicting and of suboptimal methodological quality. METHODS: The No.2-Trial was a multicenter, open-label, pragmatic, randomized trial performed in 2 Dutch hospitals. Sixty-seven patients with idiopathic STC, a defecation frequency <3 per week and refractory (ie, unresponsive) to maximal conservative (nonoperative) treatment were included. Exclusion criteria included outlet obstruction, rectal prolapse, and previous colon surgery. Patients were randomized (3:2) to SNM (n=41) or PCT (n=26) with randomization minimization between February 21, 2017 and March 12, 2020. In SNM patients, an implantable pulse generator was implanted after a successful 4-week test stimulation. PCT patients received conservative treatment such as laxatives or retrograde colonic irrigation. The primary outcome was treatment success (defined as average defecation frequency ≥3 per week) after 6 months. Secondary outcomes included constipation severity, fatigue, quality of life, and adverse events. Analysis was according to intention-to-treat. RESULTS: After 6 months, 22 (53.7%) patients were successfully treated with SNM versus 1 (3.8%) patient with PCT (odds ratio 36.4, 95% CI 3.4-387.5, P =0.003). At 6 months, SNM patients reported lower constipation severity and fatigue scores ( P <0.001) and improved quality of life compared with PCT ( P <0.001). Eight serious adverse events (6 SNM, 2 PCT) and 78 adverse events (68 SNM, 10 PCT) were reported. CONCLUSIONS: SNM is a promising surgical treatment option in a homogeneous group of adults and adolescents with refractory idiopathic STC. No.2-Trial registered at ClinicalTrials.gov NCT02961582.


Asunto(s)
Tratamiento Conservador , Terapia por Estimulación Eléctrica , Adulto , Adolescente , Humanos , Calidad de Vida , Estreñimiento/terapia , Terapia por Estimulación Eléctrica/efectos adversos , Resultado del Tratamiento
2.
J Neurooncol ; 169(1): 25-38, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38949692

RESUMEN

BACKGROUND: Tumor Treating Fields (TTFields) are alternating electric fields that disrupt cancer cell processes. TTFields therapy is approved for recurrent glioblastoma (rGBM), and newly-diagnosed (nd) GBM (with concomitant temozolomide for ndGBM; US), and for grade IV glioma (EU). We present an updated global, post-marketing surveillance safety analysis of patients with CNS malignancies treated with TTFields therapy. METHODS: Safety data were collected from routine post-marketing activities for patients in North America, Europe, Israel, and Japan (October 2011-October 2022). Adverse events (AEs) were stratified by age, sex, and diagnosis. RESULTS: Overall, 25,898 patients were included (diagnoses: ndGBM [68%], rGBM [26%], anaplastic astrocytoma/oligodendroglioma [4%], other CNS malignancies [2%]). Median (range) age was 59 (3-103) years; 66% patients were male. Most (69%) patients were 18-65 years; 0.4% were < 18 years; 30% were > 65 years. All-cause and TTFields-related AEs occurred in 18,798 (73%) and 14,599 (56%) patients, respectively. Most common treatment-related AEs were beneath-array skin reactions (43%), electric sensation (tingling; 14%), and heat sensation (warmth; 12%). Treatment-related skin reactions were comparable in pediatric (39%), adult (42%), and elderly (45%) groups, and in males (41%) and females (46%); and similar across diagnostic subgroups (ndGBM, 46%; rGBM, 34%; anaplastic astrocytoma/oligodendroglioma, 42%; other, 40%). No TTFields-related systemic AEs were reported. CONCLUSIONS: This long-term, real-world analysis of > 25,000 patients demonstrated good tolerability of TTFields in patients with CNS malignancies. Most therapy-related AEs were manageable localized, non-serious skin events. The TTFields therapy safety profile remained consistent across subgroups (age, sex, and diagnosis), indicative of its broad applicability.


Asunto(s)
Terapia por Estimulación Eléctrica , Vigilancia de Productos Comercializados , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Adolescente , Niño , Adulto Joven , Anciano de 80 o más Años , Preescolar , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Neoplasias del Sistema Nervioso Central/terapia , Japón/epidemiología
3.
Neurourol Urodyn ; 43(1): 22-30, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37830272

RESUMEN

OBJECTIVE: Success following urological procedures is traditionally defined through objective endpoints. This approach may not capture the impact on patient satisfaction. There is a paucity of literature evaluating patient-centered metrics such as satisfaction and decisional regret in the field of urology. This study investigates long-term satisfaction and decisional regret amongst patients who underwent sacral neuromodulation (SNM) for the treatment of refractory overactive bladder (OAB). MATERIALS AND METHODS: This study retrospectively reviewed patients who underwent SNM for refractory OAB from 2015 to 2022 at a single institution serving an ethnically diverse and underrepresented community. Demographic data were collected through chart review and surveys conducted via telephone calls. Patient satisfaction and decisional regret was measured with the validated modified SDS-DRS scale (satisfaction with decision scale-decision regret scale). Descriptive statistics, Wilcoxan rank sum, and median regression analyses were performed using STATA 15.0 with p < 0.05 as significant. RESULTS: Out of 191 patients who underwent SNM, 63 were unreachable (wrong number in chart, number not in service, patient did not answer, deceased). Eighty-nine out of 128 patients reached agreed to participate (70% response rate). The mean time since surgery was 37.3 ±25.2 months. The median satisfaction with decision score was 4.0 (IQR: 3.7-4.7) with a score of 1 correlating with low satisfaction and a score of 5 correlating with high satisfaction. The median decisional regret score was 2.0 (IQR: 1.2-2.9) with a score of 1 correlating with low decisional regret and a score of 5 correlating with strong decisional regret. Ten patients reported complications after surgery, which was significantly associated with lower SDS and higher DRS scores (p < 0.01), and persisted after adjusting for age, body mass index, sex, and comorbidities (SDS ß coef: -0.84, 95% CI: -1.5 to 0.15, p = 0.02; DRS ß coef: 1.48, 95% CI: 0.55-2.41, p < 0.01). CONCLUSIONS: Patients who underwent SNM for refractory OAB overall had low regret and high satisfaction with their decision at an average 3 years of follow-up. As expected, those who developed postoperative complications had worse scores. The inclusion of patient-centric outcomes is imperative when determining the success of a surgical procedure and is useful for shared decision-making when advancing to third-line therapy for OAB. Longer-term follow-up is necessary to assess durability of high satisfaction and low regret over time.


Asunto(s)
Terapia por Estimulación Eléctrica , Vejiga Urinaria Hiperactiva , Humanos , Vejiga Urinaria Hiperactiva/terapia , Estudios Retrospectivos , Satisfacción del Paciente , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Emociones
4.
Neurourol Urodyn ; 43(3): 579-594, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38318878

RESUMEN

BACKGROUND: Sacral nerve stimulators (SNSs) are a widely accepted, efficacious surgical option to treat patients who have failed conservative management for overactive bladder, nonobstructive urinary retention, fecal incontinence, or pelvic pain. As with all implanted devices, there are associated risks for surgical site and implant infections. There are currently no clear published data or guidelines regarding treating such infections. AIMS: We present a scoping review aiming to examine the existing literature on the treatment approaches of infected SNSs. METHODS: A scoping review was conducted using Preferred Reporting Items for Systematic Review and Meta-Analysis. The search strategy focused on "sacral modulation," and "infection," and "explantation," and conservative management methods such as "antibiotics." A search was conducted on medical databases, and a grey literature search was performed. RESULTS: Thirty articles were included for data extraction. Articles were published between 2006 and 2022. Outcomes were reported for 7446 patients. Two hundred and seventy-four infection events were reported, giving an overall 3.7% infection rate. Most infection events were treated with explantation, although there is some discussion on the role of conservative management using oral and intravenous antibiotics in the literature. Articles also discussed considerations for future reimplantation after explantation of SNS. CONCLUSIONS: There are currently no treatment protocols in the literature to help guide whether a patient is suited to conservative or surgical management. There is future scope for developing treatment algorithms to guide clinicians for optimal treatment of infected sacral neuromodulation devices.


Asunto(s)
Terapia por Estimulación Eléctrica , Neuroestimuladores Implantables , Plexo Lumbosacro , Humanos , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/efectos adversos , Antibacterianos/administración & dosificación , Infecciones Relacionadas con Prótesis/terapia , Infecciones Relacionadas con Prótesis/diagnóstico , Remoción de Dispositivos , Resultado del Tratamiento
5.
Colorectal Dis ; 26(3): 417-427, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38247282

RESUMEN

AIM: Sacral neuromodulation (SNM) is a minimally invasive treatment option for functional constipation. Evidence regarding its effectiveness is contradictory, driven by heterogeneous study populations and designs. The aim of this study was to assess the effectiveness, safety and cost-effectiveness of SNM in children and adults with refractory idiopathic slow-transit constipation (STC). METHOD: OVID Medline, OVID Embase, Cochrane Library, the KSR Evidence Database, the NHS Economic Evaluation Database and the International HTA Database were searched up to 25 May 2023. For effectiveness outcomes, randomized controlled trials (RCTs) were selected. For safety outcomes, all study designs were selected. For cost-effectiveness outcomes, trial- and model-based economic evaluations were selected for review. Study selection, risk of bias and quality assessment, and data extraction were independently performed by two reviewers. For the intervention 'sacral neuromodulation' effectiveness outcomes included defaecation frequency and constipation severity. Safety and cost-effectiveness outcomes were, respectively, adverse events and incremental cost-effectiveness ratios. RESULTS: Of 1390 records reviewed, 67 studies were selected for full-text screening. For effectiveness, one cross-over and one parallel-group RCT was included, showing contradictory results. Eleven studies on safety were included (four RCTs, three prospective cohort studies and four retrospective cohort studies). Overall infection rates varied between 0% and 22%, whereas reoperation rates varied between 0% and 29%. One trial-based economic evaluation was included, which concluded that SNM was not cost-effective compared with personalized conservative treatment at a time horizon of 6 months. The review findings are limited by the small number of available studies and the heterogeneity in terms of study populations, definitions of refractory idiopathic STC and study designs. CONCLUSION: Evidence for the (cost-)effectiveness of SNM in children and adults with refractory idiopathic STC is inconclusive. Reoperation rates of up to 29% were reported.


Asunto(s)
Estreñimiento , Análisis Costo-Beneficio , Terapia por Estimulación Eléctrica , Humanos , Estreñimiento/terapia , Estreñimiento/economía , Terapia por Estimulación Eléctrica/economía , Terapia por Estimulación Eléctrica/métodos , Terapia por Estimulación Eléctrica/efectos adversos , Resultado del Tratamiento , Adulto , Plexo Lumbosacro , Femenino , Niño , Ensayos Clínicos Controlados Aleatorios como Asunto , Masculino , Sacro/inervación , Persona de Mediana Edad , Tránsito Gastrointestinal
6.
Sleep Breath ; 28(1): 165-171, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37436669

RESUMEN

PURPOSE: Little is known about sex differences in the treatment of central sleep apnea (CSA). Our post hoc analysis of the remede System Pivotal Trial aimed to determine sex-specific differences in the safety and effectiveness of treating moderate to severe CSA in adults with transvenous phrenic nerve stimulation (TPNS). METHODS: Men and women enrolled in the remede System Pivotal Trial were included in this post hoc analysis of the effect of TPNS on polysomnographic measures, Epworth Sleepiness Scale, and patient global assessment for quality of life. RESULTS: Women (n = 16) experienced improvement in CSA metrics that were comparable to the benefits experienced by men (n = 135), with central apneas being practically eliminated post TPNS. Women experienced improvement in sleep quality and architecture that was comparable to men post TPNS. While women had lower baseline apnea hypopnea index than men, their quality of life was worse at baseline. Additionally, women reported a 25-percentage point greater improvement in quality of life compared to men after 12 months of TPNS therapy. TPNS was found to be safe in women, with no related serious adverse events through 12 months post-implant, while men had a low rate of 10%. CONCLUSION: Although women had less prevalent and less severe CSA than men, they were more likely to report reduced quality of life. Transvenous phrenic nerve stimulation may be a safe and effective tool in the treatment of moderate to severe CSA in women. Larger studies of women with CSA are needed to confirm our findings. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov NCT01816776; March 22, 2013.


Asunto(s)
Terapia por Estimulación Eléctrica , Apnea Central del Sueño , Adulto , Femenino , Humanos , Masculino , Terapia por Estimulación Eléctrica/efectos adversos , Estudios de Seguimiento , Nervio Frénico , Polisomnografía , Estudios Prospectivos , Calidad de Vida , Apnea Central del Sueño/terapia , Resultado del Tratamiento
7.
Eur Arch Otorhinolaryngol ; 281(1): 461-467, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37906364

RESUMEN

PURPOSE: To evaluate the efficacy of upper airway stimulation therapy in patients with a floppy epiglottis who have experienced continuous positive airway pressure failure or intolerance. METHODS: A retrospective single-center cohort study was conducted. Patients who received an Inspire Upper Airway Stimulation system and had a 1-year follow-up were included. Baseline and one-year in-laboratory polysomnography examinations were performed. Patient characteristics, Epworth Sleepiness Scale scores and upper airway stimulation device settings were collected. RESULTS: A total of 75 patients were included, of whom 10 had a floppy epiglottis. Patients with a floppy epiglottis had a significant therapeutic response to upper airway stimulation therapy, similar to patients without a floppy epiglottis. According to the Sher's success criteria, 90% of patients with a floppy epiglottis and 68% of patients without a floppy epiglottis were responders to therapy (p = 0.149). In the floppy epiglottis group, the apnea-hypopnea index decreased from 35.1 ± 5.5 events/hour to 11.2 ± 11.3 events/hour (95% CI (15.0, 32.9), p < 0.001), similarly in the non-floppy epiglottis group, the decline was from 36.4 ± 8.3 events/hour to 14.4 ± 9.5 events/hour (95% CI (18.6, 25.2), p < 0.001, between groups p = 0.659). Comparable reductions were observed for the other respiratory parameters. CONCLUSION: Treatment of patients with obstructive sleep apnea and a floppy epiglottis can be challenging. Continuous positive airway pressure may aggravate the epiglottis collapse. Upper airway stimulation therapy can be considered an effective alternative treatment option for patients with a floppy epiglottis who have encountered either continuous positive airway pressure failure or intolerance.


Asunto(s)
Terapia por Estimulación Eléctrica , Apnea Obstructiva del Sueño , Humanos , Epiglotis , Estudios Retrospectivos , Estudios de Cohortes , Terapia por Estimulación Eléctrica/efectos adversos , Apnea Obstructiva del Sueño/cirugía , Resultado del Tratamiento
8.
Neuromodulation ; 27(6): 977-1007, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38878054

RESUMEN

INTRODUCTION: The International Neuromodulation Society convened a multispecialty group of physicians based on expertise and international representation to establish evidence-based guidance on the mitigation of neuromodulation complications. This Neurostimulation Appropriateness Consensus Committee (NACC)® project intends to update evidence-based guidance and offer expert opinion that will improve efficacy and safety. MATERIALS AND METHODS: Authors were chosen on the basis of their clinical expertise, familiarity with the peer-reviewed literature, research productivity, and contributions to the neuromodulation literature. Section leaders supervised literature searches of MEDLINE, BioMed Central, Current Contents Connect, Embase, International Pharmaceutical Abstracts, Web of Science, Google Scholar, and PubMed from 2017 (when NACC last published guidelines) to October 2023. Identified studies were graded using the United States Preventive Services Task Force criteria for evidence and certainty of net benefit. Recommendations are based on the strength of evidence or consensus when evidence was scant. RESULTS: The NACC examined the published literature and established evidence- and consensus-based recommendations to guide best practices. Additional guidance will occur as new evidence is developed in future iterations of this process. CONCLUSIONS: The NACC recommends best practices regarding the mitigation of complications associated with neurostimulation to improve safety and efficacy. The evidence- and consensus-based recommendations should be used as a guide to assist decision-making when clinically appropriate.


Asunto(s)
Consenso , Terapia por Estimulación Eléctrica , Humanos , Terapia por Estimulación Eléctrica/métodos , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/normas , Terapia por Estimulación Eléctrica/instrumentación , Medicina Basada en la Evidencia/normas
9.
Pain Pract ; 24(4): 673-676, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38102861

RESUMEN

BACKGROUND: One of the unique advances in neuromodulation for chronic pain has been spinal cord stimulators (SCS) and dorsal root ganglion stimulators (DRG-S). These devices have aided in conditions such as neuropathic pain, complex regional pain syndromes, failed back surgery, and peripheral neuropathies. With these benefits, however, complications from implantable stimulators have included lead fractures and migration. The authors reviewed a lead migration, kinking, and subsequent fracture event involving a patient with complex regional pain syndrome (CRPS) II, who was treated with a DRG-S. CASE PRESENTATION: The case report follows this patient, from their past medical history to assessment of appropriate qualifications for neuromodulation, to successful surgical placement, to follow-up care. The authors further monitored assessment of inefficacy of pain relief, and identification of lead migration and kinking through imaging. In the process of removal, due to lead stress, lead fracturing occurred. After lead removal, the leads were fully replaced, and the patient was followed up and experienced improved pain relief. CONCLUSION: The case report assesses probable mechanisms of lead fracture and considerations for physicians for future assessment and triage of neuromodulation efficacy.


Asunto(s)
Dolor Crónico , Síndromes de Dolor Regional Complejo , Terapia por Estimulación Eléctrica , Neuralgia , Estimulación de la Médula Espinal , Humanos , Ganglios Espinales , Síndromes de Dolor Regional Complejo/etiología , Síndromes de Dolor Regional Complejo/terapia , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Dolor Crónico/etiología , Dolor Crónico/terapia , Neuralgia/terapia , Estimulación de la Médula Espinal/efectos adversos , Estimulación de la Médula Espinal/métodos
10.
Artículo en Ruso | MEDLINE | ID: mdl-38549408

RESUMEN

OBJECTIVE: To evaluate the clinical efficacy of long-term spinal and sacral programmable neurostimulation for pelvic organ dysfunction in patients with myelodysplasia and chronic dysfunction of the bladder and rectum. MATERIAL AND METHODS: A retrospective study included 32 children aged 1-17 years (mean 10.7) with myelodysplasia, pelvic organ dysfunction and ineffective therapy including botulinum therapy and exclusion of tethered spinal cord syndrome. All children underwent comprehensive urodynamic examination with analysis of bladder and residual urine volume, mean flow rate, intravesical pressure and total urine volume, as well as electromyographic examination. Examination was carried out before surgery, after 6, 12 and 36 months. We applied urinary diary, NBSS questionnaire and urodynamic examination data. All patients underwent neurological examinations (neurological status, magnetic resonance imaging of the spinal cord, computed tomography and radiography of the spine, electroneuromyography). The study was conducted at the neurosurgical department of the Republican Children's Clinical Hospital in Ufa between 2014 and 2022. There were 32 implantations of epidural neurostimulators for pelvic organ dysfunctions. RESULTS: Patients used epidural spinal and sacral stimulation up to 6 times a day for 10-15 min turning on the pulse generator. This method significantly increased urinary volume, decreased episodes of urinary leakage and fecal incontinence, residual volume after urination and number of periodic catheterizations compared to baseline data. Sixteen patients were very satisfied, 10 ones were moderately satisfied, and 2 patients were not satisfied with therapy. The number of bladder catheterizations per day decreased by 51.1%. Urine volume significantly increased from 131.5±16.1 to 236±16.7 ml, intravesical pressure decreased from 23.5±4.2 to 18.5±2.1 cm H2O (by 20.3%). CONCLUSION: Chronic epidural spinal and sacral stimulation can improve the quality of life in patients with pelvic organ dysfunction. This technique may be effective for pelvic organ dysfunction caused by myelodysplasia.


Asunto(s)
Terapia por Estimulación Eléctrica , Vejiga Urinaria Neurogénica , Niño , Humanos , Calidad de Vida , Estudios Retrospectivos , Insuficiencia Multiorgánica/complicaciones , Insuficiencia Multiorgánica/terapia , Vejiga Urinaria Neurogénica/etiología , Vejiga Urinaria Neurogénica/terapia , Sacro/diagnóstico por imagen , Resultado del Tratamiento , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos
11.
Neurourol Urodyn ; 42(8): 1655-1667, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37497812

RESUMEN

INTRODUCTION: Over 350 000 sacral neuromodulation (SNM) devices have been implanted since approval by the Food and Drug Administration (FDA) in 1998. SNM technology and clinical applications have evolved, with minimal safety updates after initial trials. We aim to provide an updated overview of real-world SNM safety. These insights will guide informed consent, preoperative counseling, and patient expectation-setting. MATERIALS AND METHODS: The FDA Manufacturer and User Facility Device Experience (MAUDE) database is a repository for medical device safety reports. We performed MAUDE categorical (1/1/98-12/31/10) and keyword (1/1/11-9/30/21) searches for "Interstim." A random sample of 1000 reports was reviewed and categorized by theme. To corroborate our MAUDE database analysis, a legal librarian searched the Public Access to Court Electronic Records (PACER) database, as well as Bloomberg Law's dockets database for all lawsuits related to SNM devices. RESULTS: Our search of the MAUDE database returned 44 122 SNM-related adverse events (AEs). The figure illustrates the prevalence of event categories in the random sample. The largest proportion of reports (25.6%) related to a patient's need for assistance with device use, followed by loss/change of efficacy (19.0%). Interestingly, a fall preceded issue onset in 32% of non-shock pain, 30% of lead/device migration, and 27% of painful shock reports. Our legal search revealed only four lawsuits: one for patient complications after an SNM device was used off-label, one case of transverse myelitis after implant, one for device migration or poor placement, and the fourth claimed the device malfunctioned requiring removal and causing permanent injury. CONCLUSIONS: This review confirms the real-world safety of SNM devices and very low complication rates as seen in the original clinical trials. Our findings indicate that 43.2% (95% confidence interval 40.1%-46.3%) of SNM "complications" are not AEs, per se, but rather reflect a need for improved technical support or more comprehensive informed consent to convey known device limitations to the patient, such as battery life. Similarly, the number of lawsuits is shockingly low for a device that has been in the market for 24 years, reinforcing the safety of the device. Legal cases involving SNM devices seem to relate to inappropriate patient selection-including at least one case in which SNM was used for a non-FDA approved indication-lack of appropriate follow-up, and/or provider inability to assist the patient with utilizing the device after implantation.


Asunto(s)
Terapia por Estimulación Eléctrica , Estados Unidos , Humanos , United States Food and Drug Administration , Terapia por Estimulación Eléctrica/efectos adversos , Bases de Datos Factuales
12.
Neurourol Urodyn ; 42(3): 623-630, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36701189

RESUMEN

OBJECTIVE: To evaluate the impact of cognitive impairment (CI) diagnoses on sacral neuromodulation (SNM) outcomes in older patients. MATERIALS AND METHODS: We completed a retrospective review of all patients aged ≥55 years who underwent test-phase SNM (peripheral nerve evaluation (PNE) or stage 1) for overactive bladder (OAB) between 2014 and 2021 within a large multi-regional health system. Patient demographics, relevant comorbidities, CI diagnoses (dementia or mild CI), and SNM procedures were recorded. Logistic regression modeling was performed to evaluate the impact of CI on SNM implantation rates. RESULTS: Five-hundred and ten patients underwent SNM test phase (161 PNE, 349 Stage 1) during the study period. The mean age was 71.0(8.5) years, and most (80.6%) were female. Overall, 52(10.1%) patients had a CI diagnosis at the time of SNM, and 30 (5.8%) were diagnosed at a median of 18.5 [9.25, 39.5] months after SNM. Patients with CI diagnoses were older, with more comorbidities, and were more likely to undergo PNE. Univariable comparison found no difference in implantation rate based on pre-SNM CI (85.4% vs. 76.9%, p = 0.16). Multivariable analysis identified PNE (OR 0.43, 95% CI 0.26-0.71), age (OR 0.96, 95%CI 0.93-0.98), and prior beta-3 agonist use (OR 0.60, 95% CI 0.37-0.99) but not CI or dementia as independent negative predictors of implantation. Implanted patients had a median follow-up of 25 [12.0, 55.0] months. Explant and revision rates did not differ according to CI. CONCLUSION: Patients with OAB and CI diagnoses proceed to SNM implant at rates similar to patients without CI diagnoses. A diagnosis of CI should not necessarily exclude patients from SNM therapy for refractory OAB.


Asunto(s)
Demencia , Terapia por Estimulación Eléctrica , Vejiga Urinaria Hiperactiva , Humanos , Femenino , Anciano , Masculino , Vejiga Urinaria Hiperactiva/terapia , Vejiga Urinaria Hiperactiva/etiología , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Resultado del Tratamiento , Estudios Retrospectivos , Plexo Lumbosacro
13.
Neurourol Urodyn ; 42(6): 1329-1343, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37288591

RESUMEN

OBJECTIVE: We systematically assessed all available evidence on the efficacy and safety of sacral neuromodulation (SNM) in pregnancy. METHODS: On September 2022, a thorough search was done on Ovid, PubMed, Scopus, ProQuest, Web of Science, and The Cochrane Library. We chose studies that included pregnant women who had SNM previously. Two authors independently evaluated the quality of the study using a standardized tool of JBI. Studies were given a risk of bias rating of low, moderate, or high. Given the descriptive nature of this study, we utilized descriptive statistics to report demographic and clinical features. For continuous variables, we used mean and standard deviation, and for dichotomous data, we used frequencies and percentages. RESULTS: Out of 991 abstracts screened, only 14 studies met our inclusion criteria and were included in the review. Overall, the quality of the evidence available from the literature is low based on the design of the included studies. Fifty-eight women, including 72 pregnancies, had SNM. The indication of SNM implantation was filling phase disorders in 18 cases (30.5%), voiding dysfunction in 35 women (59.3%), IC/BPS in two cases (3.5%), and fecal incontinence. In 38 pregnancies (58.5%), the SNM status was ON during pregnancy. Forty-nine cases delivered a full-term baby (75.4%), 12 cases had pre-term labor (18.5%), two miscarriages, and two postterm pregnancies happened. The most complications in patients with devices were urinary tract infection in 15 women (23.8%), urinary retention in six patients (9.5%), and pyelonephritis in two cases (3.2%). The findings revealed that when the device was deactivated, 11 cases out of the 23 patients (47.8%) had full-term pregnancies, while in ON status, 35 out of the 38 pregnant women (92.1%) had full-term pregnancies. Nine preterm labors in OFF (39.1%), and two in ON status (5.3%) were recorded. The results revealed that this difference was statistically significant (p = 0.002), and those who turned SNM of them off had more preterm labor. Although the studies reported all neonates had a healthy status, two children had chronic motor tic problems and a pilonidal sinus in a case with an active SNM in pregnancy. However, there was no association between the SNM status and pregnancy or neonatal complications (p = 0.057). CONCLUSION: SNM activation in pregnancy seems safe and effective. The choice of whether to activate or deactivate SNM should be made on an individual basis given the current SNM evidence.


Asunto(s)
Terapia por Estimulación Eléctrica , Trabajo de Parto , Retención Urinaria , Infecciones Urinarias , Niño , Recién Nacido , Humanos , Embarazo , Femenino , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Retención Urinaria/etiología , Infecciones Urinarias/etiología , Sacro , Resultado del Tratamiento
14.
Int J Colorectal Dis ; 38(1): 189, 2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37428256

RESUMEN

INTRODUCTION: It is estimated that approximately 70% of patients with rectal cancer who undergo surgery will suffer from Low Anterior Resection Syndrome (LARS). In the last decades, sacral neuromodulation (SNM) has been widely used in urinary dysfunction and in faecal incontinence refractory to medical treatment. Its application in LARS has been investigated and has shown promising results. The paper's aim is to present a systematic review and meta-analysis of the available literature and evaluate the therapeutic success of SNM in patients with LARS. METHODS: A systematic search was performed in international health-related databases: Cochrane Library, EMBASE, PubMed and SciELO. No restrictions on year of publication or language were applied. Retrieved articles were screened and selected according to set inclusion criteria. Data items were collected and processed for each included article and a meta-analysis was done according to the PRISMA guidelines. The primary outcome was the number of successful definitive SNM implants. Further outcomes included changes in bowel habits, incontinence scores, quality of life scores, anorectal manometry data and complications. RESULTS: A total of 18 studies were included, with 164 patients being submitted to percutaneous nerve evaluation (PNE) with 91% responding successfully. During follow-up of therapeutic SNM some devices were explanted. The final clinical success rate was 77% after permanent implant. Other outcomes, such as the frequency of incontinent episodes, faecal incontinence scores, quality of life scores were overall improved after SNM. The meta-analysis showed a decrease in 10.11 incontinent episodes/week; a decrease of 9.86 points in the Wexner score and an increase in quality of life of 1.56 (pooled estimate). Changes in anorectal manometry were inconsistent. Local infection was the most common post-operative complication, followed by pain, mechanical issues, loss of efficacy and haematoma. DISCUSSION/CONCLUSION: This is the largest systematic review and meta-analysis concerning the use of SNM in LARS patients. The findings support the available evidence that sacral neuromodulation can be effective in the treatment of LARS, with significant improvement in total incontinent episodes and patients´ quality of life.


Asunto(s)
Terapia por Estimulación Eléctrica , Incontinencia Fecal , Neoplasias del Recto , Incontinencia Urinaria , Humanos , Incontinencia Fecal/etiología , Síndrome de Resección Anterior Baja , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Calidad de Vida , Neoplasias del Recto/cirugía , Terapia por Estimulación Eléctrica/efectos adversos , Plexo Lumbosacro
15.
Age Ageing ; 52(12)2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-38156975

RESUMEN

INTRODUCTION: Neuromuscular electrical stimulation (NMES) is a treatment to prevent or reverse acquired disability in hospitalised adults. We conducted a systematic review and meta-analysis of its effectiveness. METHOD: We searched MEDLINE, EMBASE, Cumulative Index to Nursing & Allied Health (CINAHL) and the Cochrane library. Inclusion criteria: randomised controlled trials of hospitalised adult patients comparing NMES to control or usual care. The primary outcome was muscle strength. Secondary outcomes were muscle size, function, hospital length of stay, molecular and cellular biomarkers, and adverse effects. We assessed risk of bias using the Cochrane risk-of-bias tool. We used Review Manager (RevMan) software for data extraction, critical appraisal and synthesis. We assessed certainty using the Grading of Recommendations Assessment, Development and Evaluation tool. RESULTS: A total of 42 papers were included involving 1,452 participants. Most studies had unclear or high risk of bias. NMES had a small effect on muscle strength (moderate certainty) (standardised mean difference (SMD) = 0.33; P < 0.00001), a moderate effect on muscle size (moderate certainty) (SMD = 0.66; P < 0.005), a small effect on walking performance (moderate certainty) (SMD = 0.48; P < 0.0001) and a small effect on functional mobility (low certainty) (SMD = 0.31; P < 0.05). There was a small and non-significant effect on health-related quality of life (very low certainty) (SMD = 0.35; P > 0.05). In total, 9% of participants reported undesirable experiences. The effects of NMES on length of hospital stay, and molecular and cellular biomarkers were unclear. CONCLUSIONS: NMES is a promising intervention component that might help to reduce or prevent hospital-acquired disability.


Asunto(s)
Terapia por Estimulación Eléctrica , Calidad de Vida , Humanos , Biomarcadores , Estimulación Eléctrica , Terapia por Estimulación Eléctrica/efectos adversos , Fuerza Muscular , Ensayos Clínicos Controlados Aleatorios como Asunto , Hospitalización
16.
J Neuroeng Rehabil ; 20(1): 129, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37752553

RESUMEN

PURPOSE: Tremor is one of the key characteristics of Parkinson's disease (PD), leading to physical disabilities and often showing limited responses to pharmacological treatments. To suppress tremors in PD patients, several types of non-invasive and non-pharmacological methods have been proposed so far. In the current systematic review, three electromagnetic-based radiation strategies including electrical stimulation, magnetic stimulation, and light stimulation methods were reviewed and compared. METHODS: Major databases were searched to retrieve eligible studies. For the meta-analysis, a random-effect Bayesian framework was used. Also, heterogeneity between studies was assessed using I2 statistic, prediction interval, and tau2. Publication bias was assessed using funnel plot, and the effectiveness of methods for reducing tremor was compared using network Bayesian meta-analysis. RESULTS AND CONCLUSION: Thirty-one studies were found for qualitative analysis, and 16 studies were found for quantitative synthesis. Based on the suppression ratio, methods can be ordered as electrical stimulation, light therapy, and magnetic stimulation. Furthermore, the results showed that electrical and magnetic stimulation were more effective for tremor suppression at early stages of PD, while light therapy was found to be more effective during the later stages of PD.


Asunto(s)
Terapia por Estimulación Eléctrica , Enfermedad de Parkinson , Humanos , Teorema de Bayes , Terapia por Estimulación Eléctrica/efectos adversos , Fenómenos Electromagnéticos , Radiación Electromagnética , Fenómenos Magnéticos , Enfermedad de Parkinson/radioterapia , Temblor/etiología , Temblor/terapia , Revisiones Sistemáticas como Asunto , Metaanálisis como Asunto
17.
Neuromodulation ; 26(8): 1867-1875, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33955131

RESUMEN

OBJECTIVES: Five to 10% of patients with stable coronary artery disease have refractory angina pectoris (RAP). These patients are restricted in performing daily activities due to angina pectoris. Spinal cord stimulation is a last resort treatment option. A number of this patient population also has an indication for a cardiac implanted electronic device (CIED) (pacemaker or implantable cardiac defibrillator). Manufacturers of spinal cord stimulators have stated a warning that interference can occur between the spinal cord stimulator and the CIED. Consequently, only a limited number of patients with RAP and a CIED have received a spinal cord stimulator. The aim of this retrospective cohort study is to determine whether spinal cord stimulation can be safely used in patients with RAP and a CIED. MATERIALS AND METHODS: All patients with RAP referred to our center were screened and included if 1) the patient received a spinal cord stimulator as treatment for RAP and if 2) the patient received a CIED either prior to or after spinal cord stimulator implantation. A transcutaneous electrical nerve stimulation (TENS) treadmill test was used as a screening tool to determine whether the patient was eligible for implantation of a spinal cord stimulator. Interference between the spinal cord stimulator and CIED was checked 1) after TENS treadmill test, 2) during implantation of spinal cord stimulator or CIED, 3) during mode switches of the SCS, and 4) during regular out patient follow-up. RESULTS: In total, 22 patients had both a spinal cord stimulator and a CIED with an average follow-up duration of 44.5 months. No interference between the spinal cord stimulator and CIED was found. CONCLUSION: Spinal cord stimulation can be safely applied in patients with a CIED provided that the CIED is checked for interference during implantation, if mode switches of the SCS occurred and once yearly after implantation according to routine follow-up.


Asunto(s)
Terapia por Estimulación Eléctrica , Estimulación de la Médula Espinal , Humanos , Estudios Retrospectivos , Estudios de Factibilidad , Angina de Pecho/terapia , Terapia por Estimulación Eléctrica/efectos adversos , Electrónica , Médula Espinal/fisiología
18.
Neuromodulation ; 26(3): 490-497, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36609087

RESUMEN

OBJECTIVES: This study aimed to evaluate the safety and applicability of treating chronic respiratory insufficiency with diaphragm pacing relative to mechanical ventilation. MATERIALS AND METHODS: A literature review and analysis were conducted using the safety, appropriateness, financial neutrality, and efficacy principles. RESULTS: Although mechanical ventilation is clearly indicated in acute respiratory failure, diaphragm pacing improves life expectancy, increases quality of life, and reduces complications in patients with chronic respiratory insufficiency. CONCLUSION: Diaphragm pacing should be given more consideration in appropriately selected patients with chronic respiratory insufficiency.


Asunto(s)
Terapia por Estimulación Eléctrica , Insuficiencia Respiratoria , Humanos , Diafragma , Calidad de Vida , Insuficiencia Respiratoria/terapia , Insuficiencia Respiratoria/etiología , Respiración Artificial/efectos adversos , Terapia por Estimulación Eléctrica/efectos adversos
19.
Neuromodulation ; 26(8): 1836-1844, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35977853

RESUMEN

OBJECTIVES: In patients with detrusor overactivity with impaired contractility (DOIC), it is difficult to relieve abnormal lower urinary tract symptoms during both storage and voiding using sacral neuromodulation (SNM) with constant frequency stimulation (CFS). We sought to evaluate the efficacy and safety of SNM using variable frequency stimulation (VFS) in patients with DOIC by comparing it with outcomes of SNM with CFS. MATERIALS AND METHODS: Between September 2020 and May 2021, we prospectively enrolled 20 patients with DOIC, confirmed on urodynamic examination, and administered SNM with VFS. The patients were followed up and required to maintain voiding diaries and record scale scores of overactive bladder symptoms, psychology and quality of life, uroflowmetry, ultrasonic postvoid residual urine, and adverse events at baseline and during the CFS and VFS phases. RESULTS: The average testing phase was 26.3 ± 4.1 days. Compared with baseline values, overactive bladder symptom, psychologic health questionnaire, and quality of life scores, in addition to voiding frequency, urgency incontinence frequency, daily catheterization volume of voiding diary, and ultrasonic postvoid residual (PVR) decreased significantly during both the CFS and VFS phases (p < 0.05). The average voided volume, functional bladder capacity, and maximum urine flow rate significantly increased during the CFS and VFS phases (p < 0.05). In the VFS phase, voiding frequency, urgency incontinence frequency, daily catheterization volume of voiding diary, and ultrasonic PVR further decreased (p < 0.05), whereas functional bladder capacity, maximum urine flow rate, quality of life score, overactive bladder symptom score, and psychologic health questionnaire score further improved compared with results obtained in the CFS phase (p < 0.05). In the VFS phase, the success rate of further improvement of symptoms was 85.0%, and no new complications were noted. CONCLUSIONS: SNM that converts CFS into VFS may be an effective treatment option for patients with DOIC, exhibiting no increase in adverse events.


Asunto(s)
Terapia por Estimulación Eléctrica , Vejiga Urinaria Hiperactiva , Humanos , Vejiga Urinaria Hiperactiva/terapia , Estudios Prospectivos , Calidad de Vida , Micción , Resultado del Tratamiento , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/métodos , Urodinámica
20.
Neuromodulation ; 26(8): 1823-1830, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35690510

RESUMEN

OBJECTIVES: The aims of this study were to 1) determine the success rate of the tined lead test phase in patients with nonobstructive urinary retention (NOUR), 2) determine predictive factors of a successful test phase in patients with NOUR, and 3) determine long-term treatment efficacy and satisfaction in patients with NOUR. MATERIALS AND METHODS: The first part was a multicenter retrospective study at two centers in The Netherlands. Patients with NOUR received a four-week tined lead test phase. Success was defined as a ≥50% reduction of clean intermittent catheterization frequency or postvoid residual. We analyzed possible predictors of success with multivariable logistic regression. Second, all patients received a questionnaire to assess efficacy, perceived health (Patient Global Impression of Improvement), and treatment satisfaction. RESULTS: This study included 215 consecutive patients (82 men and 133 women) who underwent a tined lead test phase for the treatment of NOUR. The success rate in women was significantly higher than in men, respectively 62% (83/133) and 22% (18/82, p < 0.001). In women, age per ten years (odds ratio [OR] 0.74, 95% CI: 0.59-0.93) and a history of psychiatric illness (OR 3.92, 95% CI: 1.51-10.2), including posttraumatic stress disorder (PTSD), significantly predicted first stage sacral neuromodulation (SNM) success. In men, age per ten years (OR 0.43, 95% CI: 0.25-0.72) and previous transurethral resection of the prostate and/or bladder neck incision (OR 7.71, 95% CI: 1.43-41.5) were significant predictors of success. Conversely, inability to void during a urodynamic study (for women, OR 0.79, 95% CI: 0.35-1.78; for men, OR 3.06, 95% CI: 0.83-11.3) was not predictive of success. Of the patients with a successful first stage, 75% (76/101) responded to the questionnaire at a median follow-up of three years. Of these patients, 87% (66/76) continued to use their SNM system, and 92% (70/76) would recommend SNM to other patients. CONCLUSIONS: A history of psychiatric illness, including PTSD, in women with NOUR increased the odds of first stage SNM success 3.92 times. A previous transurethral resection of the prostate and/or bladder neck incision in men increased the odds of success 7.71 times. In addition, a ten-year age increase was associated with an OR of 0.43 in men and 0.74 in women, indicating a 2.3- and 1.3-times decreased odds of success, respectively.


Asunto(s)
Terapia por Estimulación Eléctrica , Resección Transuretral de la Próstata , Vejiga Urinaria Hiperactiva , Retención Urinaria , Masculino , Humanos , Femenino , Niño , Retención Urinaria/etiología , Retención Urinaria/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Terapia por Estimulación Eléctrica/efectos adversos , Vejiga Urinaria Hiperactiva/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA