Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.654
Filtrar
Más filtros

Intervalo de año de publicación
1.
Nature ; 629(8013): 810-818, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38778234

RESUMEN

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Asunto(s)
Velocidad del Flujo Sanguíneo , Encéfalo , Circulación Cerebrovascular , Ultrasonografía , Humanos , Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Circulación Cerebrovascular/fisiología , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Errores Médicos , Relación Señal-Ruido , Piel , Cráneo , Somnolencia/fisiología , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Adulto
2.
PLoS Comput Biol ; 20(6): e1012231, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38900817

RESUMEN

Computational fluid dynamics (CFD) can be used for non-invasive evaluation of hemodynamics. However, its routine use is limited by labor-intensive manual segmentation, CFD mesh creation, and time-consuming simulation. This study aims to train a deep learning model to both generate patient-specific volume-meshes of the pulmonary artery from 3D cardiac MRI data and directly estimate CFD flow fields. This proof-of-concept study used 135 3D cardiac MRIs from both a public and private dataset. The pulmonary arteries in the MRIs were manually segmented and converted into volume-meshes. CFD simulations were performed on ground truth meshes and interpolated onto point-point correspondent meshes to create the ground truth dataset. The dataset was split 110/10/15 for training, validation, and testing. Image2Flow, a hybrid image and graph convolutional neural network, was trained to transform a pulmonary artery template to patient-specific anatomy and CFD values, taking a specific inlet velocity as an additional input. Image2Flow was evaluated in terms of segmentation, and the accuracy of predicted CFD was assessed using node-wise comparisons. In addition, the ability of Image2Flow to respond to increasing inlet velocities was also evaluated. Image2Flow achieved excellent segmentation accuracy with a median Dice score of 0.91 (IQR: 0.86-0.92). The median node-wise normalized absolute error for pressure and velocity magnitude was 11.75% (IQR: 9.60-15.30%) and 9.90% (IQR: 8.47-11.90), respectively. Image2Flow also showed an expected response to increased inlet velocities with increasing pressure and velocity values. This proof-of-concept study has shown that it is possible to simultaneously perform patient-specific volume-mesh based segmentation and pressure and flow field estimation using Image2Flow. Image2Flow completes segmentation and CFD in ~330ms, which is ~5000 times faster than manual methods, making it more feasible in a clinical environment.


Asunto(s)
Hemodinámica , Imagenología Tridimensional , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Arteria Pulmonar , Humanos , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Hemodinámica/fisiología , Modelos Cardiovasculares , Hidrodinámica , Prueba de Estudio Conceptual , Aprendizaje Profundo , Velocidad del Flujo Sanguíneo/fisiología , Biología Computacional/métodos
3.
Genes Dev ; 31(13): 1308-1324, 2017 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-28779009

RESUMEN

Sufficient blood flow to tissues relies on arterial blood vessels, but the mechanisms regulating their development are poorly understood. Many arteries, including coronary arteries of the heart, form through remodeling of an immature vascular plexus in a process triggered and shaped by blood flow. However, little is known about how cues from fluid shear stress are translated into responses that pattern artery development. Here, we show that mice lacking endothelial Dach1 had small coronary arteries, decreased endothelial cell polarization, and reduced expression of the chemokine Cxcl12 Under shear stress in culture, Dach1 overexpression stimulated endothelial cell polarization and migration against flow, which was reversed upon CXCL12/CXCR4 inhibition. In vivo, DACH1 was expressed during early arteriogenesis but was down in mature arteries. Mature artery-type shear stress (high, uniform laminar) specifically down-regulated DACH1, while the remodeling artery-type flow (low, variable) maintained DACH1 expression. Together, our data support a model in which DACH1 stimulates coronary artery growth by activating Cxcl12 expression and endothelial cell migration against blood flow into developing arteries. This activity is suppressed once arteries reach a mature morphology and acquire high, laminar flow that down-regulates DACH1. Thus, we identified a mechanism by which blood flow quality balances artery growth and maturation.


Asunto(s)
Vasos Coronarios/crecimiento & desarrollo , Proteínas del Ojo/genética , Proteínas del Ojo/metabolismo , Neovascularización Fisiológica/genética , Transducción de Señal/genética , Animales , Velocidad del Flujo Sanguíneo/fisiología , Movimiento Celular/genética , Células Cultivadas , Quimiocina CXCL12/genética , Vasos Coronarios/fisiopatología , Células Endoteliales/citología , Regulación del Desarrollo de la Expresión Génica/genética , Humanos , Ratones , Ratones Endogámicos C57BL , Mutación , Técnicas de Cultivo de Órganos , Receptores CXCR4/genética , Estrés Mecánico
4.
J Physiol ; 602(10): 2227-2251, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38690610

RESUMEN

Passive whole-body hyperthermia increases limb blood flow and cardiac output ( Q ̇ $\dot Q$ ), but the interplay between peripheral and central thermo-haemodynamic mechanisms remains unclear. Here we tested the hypothesis that local hyperthermia-induced alterations in peripheral blood flow and blood kinetic energy modulate flow to the heart and Q ̇ $\dot Q$ . Body temperatures, regional (leg, arm, head) and systemic haemodynamics, and left ventricular (LV) volumes and functions were assessed in eight healthy males during: (1) 3 h control (normothermic condition); (2) 3 h of single-leg heating; (3) 3 h of two-leg heating; and (4) 2.5 h of whole-body heating. Leg, forearm, and extracranial blood flow increased in close association with local rises in temperature while brain perfusion remained unchanged. Increases in blood velocity with small to no changes in the conduit artery diameter underpinned the augmented limb and extracranial perfusion. In all heating conditions, Q ̇ $\dot Q$ increased in association with proportional elevations in systemic vascular conductance, related to enhanced blood flow, blood velocity, vascular conductance and kinetic energy in the limbs and head (all R2 ≥ 0.803; P < 0.001), but not in the brain. LV systolic (end-systolic elastance and twist) and diastolic functional profiles (untwisting rate), pulmonary ventilation and systemic aerobic metabolism were only altered in whole-body heating. These findings substantiate the idea that local hyperthermia-induced selective alterations in peripheral blood flow modulate the magnitude of flow to the heart and Q ̇ $\dot Q$ through changes in blood velocity and kinetic energy. Localised heat-activated events in the peripheral circulation therefore affect the human heart's output. KEY POINTS: Local and whole-body hyperthermia increases limb and systemic perfusion, but the underlying peripheral and central heat-sensitive mechanisms are not fully established. Here we investigated the regional (leg, arm and head) and systemic haemodynamics (cardiac output: Q ̇ $\dot Q$ ) during passive single-leg, two-leg and whole-body hyperthermia to determine the contribution of peripheral and central thermosensitive factors in the control of human circulation. Single-leg, two-leg, and whole-body hyperthermia induced graded increases in leg blood flow and Q ̇ $\dot Q$ . Brain blood flow, however, remained unchanged in all conditions. Ventilation, extracranial blood flow and cardiac systolic and diastolic functions only increased during whole-body hyperthermia. The augmented Q ̇ $\dot Q$ with hyperthermia was tightly related to increased limb and head blood velocity, flow and kinetic energy. The findings indicate that local thermosensitive mechanisms modulate regional blood velocity, flow and kinetic energy, thereby controlling the magnitude of flow to the heart and thus the coupling of peripheral and central circulation during hyperthermia.


Asunto(s)
Gasto Cardíaco , Hipertermia , Humanos , Masculino , Adulto , Hipertermia/fisiopatología , Gasto Cardíaco/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Flujo Sanguíneo Regional/fisiología , Fiebre/fisiopatología , Adulto Joven , Calor , Hemodinámica
5.
Am J Physiol Heart Circ Physiol ; 326(5): H1105-H1116, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38391313

RESUMEN

Whether cerebral sympathetic-mediated vasomotor control can be modulated by local brain activity remains unknown. This study tested the hypothesis that the application or removal of a cognitive task during a cold pressor test (CPT) would attenuate and restore decreases in cerebrovascular conductance (CVC), respectively. Middle cerebral artery blood velocity (transcranial Doppler) and mean arterial pressure (finger photoplethysmography) were examined in healthy adults (n = 16; 8 females and 8 males) who completed a control CPT, followed by a CPT coupled with a cognitive task administered either 1) 30 s after the onset of the CPT and for the duration of the CPT or 2) at the onset of the CPT and terminated 30 s before the end of the CPT (condition order was counterbalanced). The major finding was that the CPT decreased the index of CVC, and such decreases were abolished when a cognitive task was completed concurrently and restored when the cognitive task was removed. As a secondary experiment, vasomotor interactions between sympathetic transduction pathways (α1-adrenergic and Y1-peptidergic) and compounds implicated in cerebral blood flow control [adenosine, and adenosine triphosphate (ATP)] were explored in isolated porcine cerebral arteries (wire myography). The data reveal α1-receptor agonism potentiated vasorelaxation modestly in response to adenosine, and preexposure to ATP attenuated contractile responses to α1-agonism. Overall, the data suggest a cognitive task attenuates decreases in CVC during sympathoexcitation, possibly related to an interaction between purinergic and α1-adrenergic signaling pathways.NEW & NOTEWORTHY The present study demonstrates that the cerebrovascular conductance index decreases during sympathoexcitation and this response can be positively and negatively modulated by the application or withdrawal of a nonexercise cognitive task. Furthermore, isolated vessel experiments reveal that cerebral α1-adrenergic agonism potentiates adenosine-mediated vasorelaxation and ATP attenuates α1-adrenergic-mediated vasocontraction.


Asunto(s)
Adenosina Trifosfato , Simpaticolíticos , Adulto , Masculino , Femenino , Humanos , Animales , Porcinos , Velocidad del Flujo Sanguíneo/fisiología , Adrenérgicos , Adenosina/farmacología , Circulación Cerebrovascular/fisiología , Presión Sanguínea/fisiología , Frío
6.
Magn Reson Med ; 91(4): 1384-1403, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38181170

RESUMEN

PURPOSE: To present a theoretical framework that rigorously defines and analyzes key concepts and quantities for velocity selective arterial spin labeling (VSASL). THEORY AND METHODS: An expression for the VSASL arterial delivery function is derived based on (1) labeling and saturation profiles as a function of velocity and (2) physiologically plausible approximations of changes in acceleration and velocity across the vascular system. The dependence of labeling efficiency on the amplitude and effective bolus width of the arterial delivery function is defined. Factors that affect the effective bolus width are examined, and timing requirements to minimize quantitation errors are derived. RESULTS: The model predicts that a flow-dependent negative bias in the effective bolus width can occur when velocity selective inversion (VSI) is used for the labeling module and velocity selective saturation (VSS) is used for the vascular crushing module. The bias can be minimized by choosing a nominal labeling cutoff velocity that is lower than the nominal cutoff velocity of the vascular crushing module. CONCLUSION: The elements of the model are specified in a general fashion such that future advances can be readily integrated. The model can facilitate further efforts to understand and characterize the performance of VSASL and provide critical theoretical insights that can be used to design future experiments and develop novel VSASL approaches.


Asunto(s)
Arterias , Angiografía por Resonancia Magnética , Marcadores de Spin , Arterias/diagnóstico por imagen , Modelos Teóricos , Aceleración , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología
7.
Magn Reson Med ; 92(2): 761-771, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38523590

RESUMEN

PURPOSE: This study evaluated the velocity-selective (VS) MRA with different VS labeling modules, including double refocused hyperbolic tangent, eight-segment B1-insensitive rotation, delay alternating with nutation for tailored excitation, Fourier transform-based VS saturation, and Fourier transform-based inversion. METHODS: These five VS labeling modules were evaluated first through Bloch simulations, and then using VSMRA directly on various cerebral arteries of healthy subjects. The relative signal ratios from arterial ROIs and surrounding tissues as well as relative arteria-tissue contrast ratios of different methods were compared. RESULTS: Double refocused hyperbolic tangent and eight-segment B1-insensitive rotation showed very similar labeling effects. Delay alternating with nutation for tailored excitation yielded high arterial signal but with residual tissue signal due to the spatial banding effect. Fourier transform-based VS saturation with half the time of other techniques serves as an efficient nonsubtractive VSMRA method, but the remaining tissue signal still obscured some small distal arteries that were delineated by other subtraction-based VSMRA, allowing more complete cancelation of static tissue. Fourier transform-based inversion produced the highest arterial signal in VSMRA with minimal tissue background. CONCLUSION: This is the first study that angiographically compared five different VS labeling modules. Their labeling characteristics on arteries and tissue and implications for VSMRA and VS arterial spin labeling are discussed.


Asunto(s)
Arterias Cerebrales , Análisis de Fourier , Angiografía por Resonancia Magnética , Humanos , Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/fisiología , Angiografía por Resonancia Magnética/métodos , Adulto , Masculino , Femenino , Algoritmos , Velocidad del Flujo Sanguíneo/fisiología , Marcadores de Spin , Angiografía Cerebral/métodos , Circulación Cerebrovascular/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Asistida por Computador/métodos
8.
Magn Reson Med ; 92(1): 332-345, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38469983

RESUMEN

PURPOSE: The delay alternating with nutation for tailored excitation (DANTE)-sampling perfection with application-optimized contrasts (SPACE) sequence facilitates 3D intracranial vessel wall imaging with simultaneous suppression of blood and CSF. However, the achieved image contrast depends closely on the selected sequence parameters, and the clinical use of the sequence is limited in vivo by observed signal variations in the vessel wall, CSF, and blood. This paper introduces a comprehensive DANTE-SPACE simulation framework, with the aim of providing a better understanding of the underlying contrast mechanisms and facilitating improved parameter selection and contrast optimization. METHODS: An extended phase graph formalism was developed for efficient spin ensemble simulation of the DANTE-SPACE sequence. Physiological processes such as pulsatile flow velocity variation, varying flow directions, intravoxel velocity variation, diffusion, and B 1 + $$ {\mathrm{B}}_1^{+} $$ effects were included in the framework to represent the mechanisms behind the achieved signal levels accurately. RESULTS: Intravoxel velocity variation improved temporal stability and robustness against small velocity changes. Time-varying pulsatile velocity variation affected CSF simulations, introducing periods of near-zero velocity and partial rephasing. Inclusion of diffusion effects was found to substantially reduce the CSF signal. Blood flow trajectory variations had minor effects, but B 1 + $$ {\mathrm{B}}_1^{+} $$ differences along the trajectory reduced DANTE efficiency in low- B 1 + $$ {\mathrm{B}}_1^{+} $$ areas. Introducing low-velocity pulsatility of both CSF and vessel wall helped explain the in vivo observed signal heterogeneity in both tissue types. CONCLUSION: The presented simulation framework facilitates a more comprehensive optimization of DANTE-SPACE sequence parameters. Furthermore, the simulation framework helps to explain observed contrasts in acquired data.


Asunto(s)
Algoritmos , Encéfalo , Simulación por Computador , Imagenología Tridimensional , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/irrigación sanguínea , Imagenología Tridimensional/métodos , Velocidad del Flujo Sanguíneo/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Flujo Pulsátil/fisiología , Circulación Cerebrovascular/fisiología , Imagen por Resonancia Magnética/métodos
9.
Magn Reson Med ; 92(1): 158-172, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38411277

RESUMEN

PURPOSE: Abnormalities in cerebral veins are a common finding in many neurological diseases, yet there is a scarcity of MRI techniques to assess venous hemodynamic function. The present study aims to develop a noncontrast technique to measure a novel blood flow circulatory measure, venous transit time (VTT), which denotes the time it takes for water to travel from capillary to major veins. METHODS: The proposed sequence, venous transit time imaging by changes in T1 relaxation (VICTR), is based on the notion that as water molecules transition from the tissue into the veins, they undergo a change in T1 relaxation time. The validity of the measured VTT was tested by studying the VTT along the anatomically known flow trajectory of venous vessels as well as using a physiological vasoconstrictive challenge of caffeine ingestion. Finally, we compared the VTT measured with VICTR MRI to a bolus-tracking method using gadolinium-based contrast agent. RESULTS: VTT was measured to be 3116.3 ± 326.0 ms in the posterior superior sagittal sinus (SSS), which was significantly longer than 2865.0 ± 390.8 ms at the anterior superior sagittal sinus (p = 0.004). The test-retest assessment showed an interclass correlation coefficient of 0.964. VTT was significantly increased by 513.8 ± 239.3 ms after caffeine ingestion (p < 0.001). VTT measured with VICTR MRI revealed a strong correlation (R = 0.84, p = 0.002) with that measured with the contrast-based approach. VTT was found inversely correlated to cerebral blood flow and venous oxygenation across individuals. CONCLUSION: A noncontrast MRI technique, VICTR MRI, was developed to measure the VTT of the brain.


Asunto(s)
Venas Cerebrales , Imagen por Resonancia Magnética , Humanos , Masculino , Adulto , Femenino , Velocidad del Flujo Sanguíneo/fisiología , Venas Cerebrales/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Circulación Cerebrovascular/fisiología , Reproducibilidad de los Resultados , Cafeína/farmacología , Medios de Contraste , Adulto Joven , Procesamiento de Imagen Asistido por Computador/métodos , Hemodinámica , Angiografía por Resonancia Magnética/métodos
10.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38440807

RESUMEN

PURPOSE: Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T. METHODS: Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated. RESULTS: Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups. CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.


Asunto(s)
Arterias Cerebrales , Imagen por Resonancia Magnética , Flujo Pulsátil , Humanos , Femenino , Masculino , Adulto , Anciano , Reproducibilidad de los Resultados , Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/fisiología , Flujo Pulsátil/fisiología , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Adulto Joven , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Angiografía por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos
11.
Opt Lett ; 49(13): 3600-3603, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38950219

RESUMEN

Visualizing a 3D blood flow velocity field through noninvasive imaging is crucial for analyzing hemodynamic mechanisms in areas prone to disorders. However, traditional correlation-based optical coherence tomography (OCT) velocimetry techniques have a maximum measurable flow velocity depending on the A-line rate. We presented the ergodic speckle contrast OCT (ESCOCT) to break the bottleneck in measuring the rapid blood flow velocity. It achieved a measurement of blood flow velocity ranging from 9.5 to 280 mm/s using a 100 kHz swept-source (SS) OCT based on 100 A-repeats scanning mode. Addressing the non-ergodic problem of temporal OCT signals by integrating more consecutive A-scans, ESCOCT can enable the estimation for lower velocity flows by increasing A-repeats. ESCOCT provided a wide dynamic range with no upper limit on measuring blood flow velocity with an adequate signal-to-noise ratio and improved the sensitivity and accuracy of the hemodynamic assessment.


Asunto(s)
Tomografía de Coherencia Óptica , Tomografía de Coherencia Óptica/métodos , Velocidad del Flujo Sanguíneo/fisiología , Reología/métodos , Humanos , Relación Señal-Ruido
12.
Exp Physiol ; 109(4): 614-623, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38376110

RESUMEN

The mean flow index-usually referred to as Mx-has been used for assessing dynamic cerebral autoregulation (dCA) for almost 30 years. However, concerns have arisen regarding methodological consistency, construct and criterion validity, and test-retest reliability. Methodological nuances, such as choice of input (cerebral perfusion pressure, invasive or non-invasive arterial pressure), pre-processing approach and artefact handling, significantly influence mean flow index values, and previous studies correlating mean flow index with other established dCA metrics are confounded by inherent methodological flaws like heteroscedasticity, while the mean flow index also fails to discriminate individuals with presumed intact versus impaired dCA (discriminatory validity), and its prognostic performance (predictive validity) across various conditions remains inconsistent. The test-retest reliability, both within and between days, is generally poor. At present, no single approach for data collection or pre-processing has proven superior for obtaining the mean flow index, and caution is advised in the further use of mean flow index-based measures for assessing dCA, as current evidence does not support their clinical application.


Asunto(s)
Presión Arterial , Circulación Cerebrovascular , Humanos , Reproducibilidad de los Resultados , Homeostasis/fisiología , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Ultrasonografía Doppler Transcraneal , Presión Sanguínea/fisiología
13.
PLoS Comput Biol ; 19(12): e1011665, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38048371

RESUMEN

The development of a functional cardiovascular system ensures a sustainable oxygen, nutrient and hormone delivery system for successful embryonic development and homeostasis in adulthood. While early vessels are formed by biochemical signaling and genetic programming, the onset of blood flow provides mechanical cues that participate in vascular remodeling of the embryonic vascular system. The zebrafish is a prolific animal model for studying the quantitative relationship between blood flow and vascular morphogenesis due to a combination of favorable factors including blood flow visualization in optically transparent larvae. In this study, we have developed a cell-and-plasma blood transport model using computational fluid dynamics (CFD) to understand how red blood cell (RBC) partitioning affect lumen wall shear stress (WSS) and blood pressure in zebrafish trunk blood vascular networks with altered rheology and morphology. By performing live imaging of embryos with reduced hematocrit, we discovered that cardiac output and caudal artery flow rates were maintained. These adaptation trends were recapitulated in our CFD models, which showed reduction in network WSS via viscosity reduction in the caudal artery/vein and via pressure gradient weakening in the intersegmental vessels (ISVs). Embryos with experimentally reduced lumen diameter showed reduced cardiac output and caudal artery flow rate. Factoring in this trend into our CFD models, simulations highlighted that lumen diameter reduction increased vessel WSS but this increase was mitigated by flow reduction due to the adaptive network pressure gradient weakening. Additionally, hypothetical network CFD models with different vessel lumen diameter distribution characteristics indicated the significance of axial variation in lumen diameter and cross-sectional shape for establishing physiological WSS gradients along ISVs. In summary, our work demonstrates how both experiment-driven and hypothetical CFD modeling can be employed for the study of blood flow physiology during vascular remodeling.


Asunto(s)
Remodelación Vascular , Pez Cebra , Animales , Velocidad del Flujo Sanguíneo/fisiología , Simulación por Computador , Hemodinámica/fisiología , Microvasos , Estrés Mecánico , Modelos Cardiovasculares , Hidrodinámica
14.
PLoS Comput Biol ; 19(10): e1011479, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37851683

RESUMEN

Spatial patterns of elevated wall shear stress and pressure due to blood flow past aortic stenosis (AS) are studied using GPU-accelerated patient-specific computational fluid dynamics. Three cases of moderate to severe AS, one with a dilated ascending aorta and two within the normal range (root diameter less than 4cm) are simulated for physiological waveforms obtained from echocardiography. The computational framework is built based on sharp-interface Immersed Boundary Method, where aortic geometries segmented from CT angiograms are integrated into a high-order incompressible Navier-Stokes solver. The key question addressed here is, given the presence of turbulence due to AS which increases wall shear stress (WSS) levels, why some AS patients undergo much less aortic dilation. Recent case studies of AS have linked the existence of an elevated WSS hotspot (due to impingement of AS on the aortic wall) to the dilation process. Herein we further investigate the WSS distribution for cases with and without dilation to understand the possible hemodynamics which may impact the dilation process. We show that the spatial distribution of elevated WSS is significantly more focused for the case with dilation than those without dilation. We further show that this focal area accommodates a persistent pocket of high pressure, which may have contributed to the dilation process through an increased wall-normal forcing. The cases without dilation, on the contrary, showed a rather oscillatory pressure behaviour, with no persistent pressure "buildup" effect. We further argue that a more proximal branching of the aortic arch could explain the lack of a focal area of elevated WSS and pressure, because it interferes with the impingement process due to fluid suction effects. These phenomena are further illustrated using an idealized aortic geometry. We finally show that a restored inflow eliminates the focal area of elevated WSS and pressure zone from the ascending aorta.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Humanos , Válvula Aórtica/fisiología , Dilatación , Hidrodinámica , Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Hemodinámica , Estrés Mecánico , Velocidad del Flujo Sanguíneo/fisiología , Modelos Cardiovasculares
15.
Eur J Neurol ; 31(5): e16227, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38308448

RESUMEN

BACKGROUND: The aim of this study was to analyze cold stimulation-induced changes in cerebral and cardiac hemodynamics. METHODS: Upon ingestion of an ice cube, the changes in resistance index, mean flow velocity and flow index of the middle cerebral arteries (MCA) were assessed using transcranial Doppler sonography. Extracranial duplex sonography was used to measure the mean flow velocity and resistance index of the right internal carotid artery (ICA). The change in mean arterial pressure, heart rate, root mean square of successive differences (RMSSD) and end-tidal carbon dioxide pressure were analyzed additionally. These changes were compared to sham stimulation. RESULTS: Compared with sham stimulation, cooling of the oral cavity resulted in significant changes in cerebral and cardiac hemodynamics. The cold stimulation decreased the resistance index in the MCA (-4.5% ± 5.4%, p < 0.0001) and right ICA (-6.3% ± 15.6%, p = 0.001). This was accompanied by an increase in mean flow velocity (4.1% ± 8.0%, p < 0.0001) and flow index (10.1% ± 43.6%, p = 0.008) in the MCA. The cardiac effects caused an increase in mean arterial pressure (1.8% ± 11.2%, p = 0.017) and RMSSD (55% ± 112%, p = 0.048), while simultaneously decreasing the heart rate (-4.3% ± 9.6%, p = 0.0001). CONCLUSION: Cooling of the oral cavity resulted in substantial changes in cerebral and cardiac hemodynamics resulting in a blood flow diversion to the brain.


Asunto(s)
Encéfalo , Hemodinámica , Humanos , Velocidad del Flujo Sanguíneo/fisiología , Voluntarios Sanos , Hemodinámica/fisiología , Encéfalo/diagnóstico por imagen , Ultrasonografía Doppler Transcraneal , Boca , Circulación Cerebrovascular/fisiología
16.
Exp Brain Res ; 242(9): 2193-2205, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39012475

RESUMEN

A single bout of exercise as well as exposure to a hypercapnic environment increases cerebral blood flow (CBF) and is an adaptation linked to a post-intervention executive function (EF) benefit. In the present investigation we sought to determine whether a transient reduction in CBF impairs EF. Accordingly, we employed 10-min -30 mmHg and -50 mmHg lower-body negative pressure (LBNP) interventions as well as a non-LBNP control condition. LBNP was employed because it sequesters blood in the lower legs and safely and reliably decreases CBF. Transcranial Doppler ultrasound was used to measure middle cerebral artery velocity (MCAv) to estimate CBF prior to and during LBNP conditions. As well, assessments of the inhibitory control component of EF (i.e., antipointing) were completed prior to (pre-) and immediately after (i.e., post-) each condition. Antipointing requires that an individual reach mirror-symmetrical to an exogenously presented target and is a task providing the resolution to detect subtle EF changes. Results showed that LBNP produced a 14% reduction in MCAv; however, null hypothesis, equivalence and Bayesian contrasts indicated that antipointing metrics did not vary from pre- to post-intervention, and LBNP-based changes in MCAv magnitude were not reliably correlated with antipointing planning times. Hence, a 10-min reduction in CBF did not impact the efficiency or effectiveness of an inhibitory control measure of EF.


Asunto(s)
Circulación Cerebrovascular , Función Ejecutiva , Presión Negativa de la Región Corporal Inferior , Ultrasonografía Doppler Transcraneal , Humanos , Función Ejecutiva/fisiología , Circulación Cerebrovascular/fisiología , Masculino , Femenino , Presión Negativa de la Región Corporal Inferior/métodos , Adulto Joven , Adulto , Ultrasonografía Doppler Transcraneal/métodos , Arteria Cerebral Media/fisiología , Arteria Cerebral Media/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología
17.
Eur J Pediatr ; 183(8): 3509-3515, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38795136

RESUMEN

Preterm neonates are at risk for neurodevelopmental impairment, especially those with intraventricular hemorrhage (IVH). Cerebral vasospasm (VSP) is a common complication after subarachnoid hemorrhage (SAH) in adult population, but it is unknown if preterm neonates with IVH may develop it. We prospectively enrolled premature newborns < 32 weeks with IVH and without IVH. All patients received serial transcranial sonography through the temporal window of the middle cerebral artery, anterior cerebral artery, posterior cerebral artery, and the internal carotid artery with transcranial Doppler sonography days 2, 4, and 10 of life. Cerebral blood velocities (CBFVs) were measured including median velocity flow (MV), peak systolic velocity (PSV), and maximum end-diastolic velocity (EDV). Resistance index and pulsatility index were calculated. VSP was defined as an increase of 50% in the baseline velocity per day and/or a Lindegaard ratio higher than 3. Fifty subjects were enrolled. None of the patients with IVH showed elevation of MV or a Lindegaard ratio > 3. There were no differences between IVH and without IVH groups regarding resistance index and pulsatility index.    Conclusion: Preterm infants with IVH do not present a pattern of VSP analyzed by Doppler transcranial ultrasound in this pilot study. What is Known: • In adult population with subarachnoid hemorrhage the most treatable cause of cerebral ischemia is due cerebral vasospasm but is unknown if premature newborn may have vasospasm due the extravasation of blood in the context of intraventricular hemorrhage What is New: •In this pilot study we did not find in premature newborn with intraventricular hemorrhage signs of vasoespam measured by transcranial color doppler ultrasound.


Asunto(s)
Recien Nacido Prematuro , Ultrasonografía Doppler Transcraneal , Vasoespasmo Intracraneal , Humanos , Proyectos Piloto , Recién Nacido , Ultrasonografía Doppler Transcraneal/métodos , Vasoespasmo Intracraneal/diagnóstico por imagen , Vasoespasmo Intracraneal/etiología , Vasoespasmo Intracraneal/fisiopatología , Femenino , Masculino , Estudios Prospectivos , Enfermedades del Prematuro/diagnóstico por imagen , Enfermedades del Prematuro/fisiopatología , Circulación Cerebrovascular/fisiología , Velocidad del Flujo Sanguíneo/fisiología , Hemorragia Cerebral Intraventricular/diagnóstico por imagen , Hemorragia Cerebral Intraventricular/etiología
18.
Clin Auton Res ; 34(3): 353-361, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38926194

RESUMEN

PURPOSE: The compensatory mechanisms supporting cerebral perfusion throughout head-up tilt (HUT) in patients with vasovagal syncope (VVS) remain unclear. We tested the hypothesis that increased cerebrovascular compliance (Ci) and decreased cerebrovascular resistance (CVR) support cerebral blood velocity (CBV) during pre-syncope in VVS. METHODS: Finger arterial blood pressure (ABP) and right middle cerebral artery blood velocity (CBV) were recorded in 15 individuals diagnosed with VVS (n = 11 female, mean age: 40 ± 16 years, mean body mass index: 24.9 ± 4.0 kg/m2) at supine rest and during HUT (80 degree angle). Individual ABP and CBV waveforms during VVS were input into a modified Windkessel model to calculate Ci and ohmic CVR. Gosling's pulsatility index (Pi; pulse amplitude/mean CBV) was calculated. RESULTS: Diastolic ABP, systolic ABP, mean ABP (72 ± 11 to 51 ± 12 mmHg), and CVR decreased progressively during presyncope (all P ≤ 0.04). As expected, systolic CBV was sustained (all P ≥ 0.29) while diastolic and mean CBV (51 ± 13 to 38 ± 13 mmHg) fell during presyncope (all P ≤ 0.04). Both Ci and Pi increased during presyncope (128 ± 97 and 60 ± 41%, respectively; all P ≤ 0.049) and were positively correlated (R2 = 0.79, P < 0.01). Increased Ci contributed to changes in mean CBV (P < 0.01) but decreased CVR did not (P = 0.28). CONCLUSIONS: These data provide evidence that Ci increases during presyncope in patients with VVS and is likely involved in the maintenance of systolic CBV during a fall in diastolic CBV. However, this regulation is not sufficient to preserve CBV in the presence of such extreme and progressive reductions in ABP.


Asunto(s)
Circulación Cerebrovascular , Síncope Vasovagal , Pruebas de Mesa Inclinada , Humanos , Síncope Vasovagal/fisiopatología , Síncope Vasovagal/diagnóstico , Femenino , Adulto , Masculino , Circulación Cerebrovascular/fisiología , Pruebas de Mesa Inclinada/métodos , Persona de Mediana Edad , Velocidad del Flujo Sanguíneo/fisiología , Presión Sanguínea/fisiología , Resistencia Vascular/fisiología , Adulto Joven , Arteria Cerebral Media/fisiopatología , Arteria Cerebral Media/diagnóstico por imagen
19.
BMC Pregnancy Childbirth ; 24(1): 60, 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38216901

RESUMEN

BACKGROUND: Present evidence suggests that the Doppler ultrasonographic indices, such as carotid artery blood flow (CABF) and velocity time integral (VTI), had the ability to predict fluid responsiveness in non-obstetric patients. The purpose of this study was to assess their capacity to predict fluid responsiveness in spontaneous breathing parturients undergoing caesarean section and to determine the effect of detecting and management of hypovolemia (fluid responsiveness) on the incidence of hypotension after anaesthesia. METHODS: A total of 72 full term singleton parturients undergoing elective caesarean section were enrolled in this study. CABF, VTI, and hemodynamic parameters were recorded before and after fluid challenge and assessed by carotid artery ultrasonography. Fluid responsiveness was defined as an increase in stroke volume index (SVI) of 15% or more after the fluid challenge. RESULTS: Thirty-one (43%) patients were fluid responders. The area under the ROC curve to predict fluid responsiveness for CABF and VTI were 0.803 (95% CI, 0.701-0.905) and 0.821 (95% CI, 0.720-0.922). The optimal cut-off values of CABF and VTI for fluid responsiveness was 175.9 ml/min (sensitivity of 74.0%; specificity of 78.0%) and 8.7 cm/s (sensitivity of 67.0%; specificity of 90.0%). The grey zone for CABF and VTI were 114.2-175.9 ml/min and 6.8-8.7 cm/s. The incidence of hypotension after the combined spinal-epidural anaesthesia (CSEA) was significantly higher in the Responders group 25.8% (8/31) than in the Non-Responders group 17.1(7/41) (P < 0.001). The total incidence of hypotension after CSEA of the two groups was 20.8% (15/72). CONCLUSIONS: Ultrasound evaluation of CABF and VTI seem to be the feasible parameters to predict fluid responsiveness in parturients undergoing elective caesarean section and detecting and management of hypovolemia (fluid responsiveness) could significantly decrease incidence of hypotension after anaesthesia. TRIAL REGISTRATION: The trial was registered at the Chinese Clinical Trial Registry (ChiCTR) ( www.chictr.org ), registration number was ChiCTR1900022327 (The website link: https://www.chictr.org.cn/showproj.html?proj=37271 ) and the date of trial registration was in April 5, 2019. This study was performed in accordance with the Declaration of Helsinki and approved by the Research Ethics Committee of Women's Hospital, Zhejiang University School of Medicine (20,180,120).


Asunto(s)
Cesárea , Hipotensión , Humanos , Femenino , Embarazo , Cesárea/efectos adversos , Hipovolemia/etiología , Estudios Prospectivos , Hemodinámica/fisiología , Arterias Carótidas/diagnóstico por imagen , Hipotensión/etiología , Ultrasonografía de las Arterias Carótidas , Fluidoterapia , Velocidad del Flujo Sanguíneo/fisiología
20.
Heart Vessels ; 39(6): 556-562, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38368576

RESUMEN

Cardiac magnetic resonance imaging (CMR) often shows discrepancies between right ventricular outflow tract (RVOT) flow and left ventricular outflow tract flow in patients with late-stage repaired tetralogy of Fallot (rTOF), leading to potential errors in pulmonary regurgitation fraction (PRF) assessment. This study aimed to identify the conditions under which RVOT flow can be acutely evaluated using four-dimensional (4D) flow CMR. Twenty-seven consecutive patients with rTOF underwent both two-dimensional phase-contrast (2D PC) and 4D flow CMR between 2016 and 2018, excluding those with peripheral pulmonary artery stenosis, RVOT conduit replacement, unknown surgical method, and an aortic valve regurgitation greater than 20%. Seven healthy controls also underwent only 4D Flow CMR. All healthy controls and fifteen patients with rTOF showed laminar RVOT flow, while seven patients exhibited helical, and four patients exhibited vortical RVOT flow in 4D flow CMR visualization. Flow-volume concordance between the pulmonary artery and aortic flow was significantly lower in patients with rTOF and PRF > 40% in 2D PC CMR. This concordance rate in the suprapulmonary valve was high in both the TOF and control groups, comparing at five RVOT locations in 4D flow CMR. Regarding RVOT flow regurgitation in 4D flow, the whole bulk evaluation exhibited greater variation depending on the flow type compared to the whole pixel-wise evaluation. The study confirmed the flow volume at the upper section of the pulmonary valve as the most accurate correlate of aortic flow volume. Furthermore, the 4D flow CMR using the pixel-wise method demonstrated superior accuracy compared to the traditional bulk flow method.


Asunto(s)
Imagen por Resonancia Cinemagnética , Tetralogía de Fallot , Humanos , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/fisiopatología , Masculino , Femenino , Adulto , Imagen por Resonancia Cinemagnética/métodos , Velocidad del Flujo Sanguíneo/fisiología , Adolescente , Procedimientos Quirúrgicos Cardíacos/métodos , Adulto Joven , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha/fisiología , Estudios Retrospectivos , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Niño , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA