Your browser doesn't support javascript.
loading
Percutaneous closure of recanalised ductus arteriosus--a single-centre experience.
Kusa, Jacek; Szkutnik, Malgorzata; Baranowski, Jacek; Adams, Eloa; Karwot, Blandyna; Rycaj, Jaroslaw; Haponiuk, Ireneusz; Bialkowski, Jacek.
Afiliación
  • Kusa J; Oddzial Wrodzonych Wad Serca i Kardiologii Dzieci, Slaskie Centrum Chorób Serca, ul. Szpitalna 2, 41-800 Zabrze. jkusa@poczta.onet.pl
Kardiol Pol ; 65(2): 125-9; discussion 130-1, 2007 Feb.
Article en En, Pl | MEDLINE | ID: mdl-17366356
ABSTRACT

INTRODUCTION:

Restoration of blood flow through a previously occluded ductus arteriosus may occur in some patients. Treatment strategy in patients with such residual shunts has not yet been uniformly established.

AIM:

To present single-centre experience and to attempt to establish a strategy of management of patients with residual ductus arteriosus shunts following percutaneous closure.

METHODS:

Of 352 patients who underwent percutaneous closure of ductus arteriosus, in 13 subjects complete closure failed (coils and Rashkind occluders were used in 10 and 3 patients, respectively). In these patients other percutaneous interventions aiming at total closure of residual shunt were attempted.

RESULTS:

In 12 patients coils were inserted (one patient received two coils). Introduction of implant in one patient failed, but total occlusion of the shunt was confirmed one day after the procedure. Trivial residual shunt was observed in one patient after one-year follow-up.

CONCLUSIONS:

Percutaneous treatment of residual shunts within the ductus arteriosus is an effective and safe procedure. In our opinion identifying and treating such leaks is important, as it prevents complications and long-term need for antibiotic prevention of infective endocarditis. In the case of a small residual shunt, insertion of a coil seems to be the optimal therapy due to the low cost of the device, favourable design and high effectiveness. For patients in whom anatomy of the ductus arteriosus has been significantly changed, particularly in previously treated subjects, techniques using vascular loops or insertion using a catheter wedge may be helpful.
Asunto(s)
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Prótesis e Implantes / Cateterismo Cardíaco / Conducto Arterioso Permeable Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En / Pl Revista: Kardiol Pol Año: 2007 Tipo del documento: Article
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Prótesis e Implantes / Cateterismo Cardíaco / Conducto Arterioso Permeable Tipo de estudio: Observational_studies / Prognostic_studies Límite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En / Pl Revista: Kardiol Pol Año: 2007 Tipo del documento: Article