Your browser doesn't support javascript.
loading
Toward a fluorescent single-strand conformation polymorphism technique that detects all mutations: F-DOVAM-S.
Mroske, Cameron; Muci, John; Wang, Jicheng; Li, Kai; Song, Wenjia; Yan, Jin; Feng, Jinong; Liu, Qiang; Sommer, Steve S.
Afiliación
  • Mroske C; Department of Molecular Genetics and Department of Molecular Diagnosis, City of Hope National Medical Center, Duarte, CA 91010, USA.
Anal Biochem ; 368(2): 250-7, 2007 Sep 15.
Article en En | MEDLINE | ID: mdl-17618861
Although DOVAM-S (detection of virtually all mutations-SSCP) in effect detects all mutations and is less costly than direct sequencing, the technique currently requires the use of radioactivity. F-DOVAM-S (fluorescent DOVAM-S) was developed to replace the isotopic label with fluorescence and to increase throughput via dye color multiplexing. As proof of principle, two multitemperature slab gel electrophoresis conditions were evaluated through the blinded analysis of mutations in the factor IX (FIX) genes of 88 hemophilia B (HB) patients and 7 wild-type controls. Using only two conditions, it was determined that F-DOVAM-S had a detection sensitivity of 97%. It is anticipated that when three or four optimized conditions are employed, F-DOVAM-S will detect all mutations. Three patient samples were multiplexed per well using three different fluorescent dyes (6FAM, VIC, and NED), demonstrating that it is possible to analyze up to 44 kb of diploid, color-coded amplification product per gel lane. This value corresponds to a throughput of approximately 4 Mb of DNA analyzed per 96-well gel, which is approximately triple that of conventional radiolabeled DOVAM-S. Throughput is further enhanced by the rapidity at which the fluorescent signal can be captured and the resultant multicolor chromatograms analyzed. Given these data, F-DOVAM-S has the potential to be a particularly powerful technology for clinical diagnosis because it allows the mutation analysis of multiple patients to be performed within 24h.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Análisis Mutacional de ADN / Polimorfismo Conformacional Retorcido-Simple / Colorantes Fluorescentes Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Anal Biochem Año: 2007 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Análisis Mutacional de ADN / Polimorfismo Conformacional Retorcido-Simple / Colorantes Fluorescentes Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Revista: Anal Biochem Año: 2007 Tipo del documento: Article País de afiliación: Estados Unidos