Your browser doesn't support javascript.
loading
Assessment of left ventricular volume and ejection fraction: comparison of QGS and MBGS analyses of ECG-gated myocardial perfusion SPECT imaging.
Khorsand, Aliasghar; Gyöngyösi, Mariann; Graf, Senta; Zamini, Sholeh; Schuster, Ernst; Sochor, Heinz; Porenta, Gerold.
Afiliación
  • Khorsand A; Department of Cardiology, Medical University of Vienna, Rudolfinerhaus, Vienna, Austria. aliasghar.khorsand@meduniwien.ac.at
Nucl Med Commun ; 30(4): 300-7, 2009 Apr.
Article en En | MEDLINE | ID: mdl-19357490
ABSTRACT

OBJECTIVES:

The purpose of this study was to compare quantitative ECG-gated single-photon emission computed tomography (SPECT) (QGS) and model-based ECG-gated single-photon emission computed tomography (MBGS) for determination of end-diastolic cardiac volume (EDV), end-systolic cardiac volume (ESV), and left ventricular ejection fraction (LVEF). The accuracy of both methods was evaluated by measurements obtained from contrast left ventriculography (LVG).

METHODS:

Forty-five patients (40 male, age 55+/-11 years) with coronary artery disease were studied by angiography and ECG-gated SPECT using technetium-99m-sestamibi for the evaluation of myocardial perfusion and LVEF. Short axis SPECT images were analyzed by QGS and MBGS to estimate endocardial and epicardial surfaces and to derive EDV, ESV, and LVEF.

RESULTS:

EDV by gated SPECT (QGS 187+/-71 ml; MBGS 191+/-76 ml) were lower than corresponding values by LVG (203+/-59 ml), whereas ESV by gated SPECT (QGS 121+/-62 ml; MBGS 108+/-54 ml) were higher than by LVG (105+/-49 ml). Thus, LVEFs by gated SPECT (QGS 39+/-12%; MBGS 45+/-9%) were significantly lower than by LVG (50+/-15%). LVEF by MBGS was significantly higher than by QGS (P<0.05). A significant correlation was observed among QGS, MBGS, and LVG for the calculation of EDV, ESV, and LVEF.

CONCLUSION:

Measurements of LV volumes and LVEF by QGS and MBGS showed close agreement with each other and with results from LVG. However, both methods measure lower values for EDV and higher values for ESV and thus underestimate LVEF compared with LVG.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Volumen Sistólico / Imagen de Acumulación Sanguínea de Compuerta / Tomografía Computarizada de Emisión de Fotón Único / Función Ventricular Izquierda / Circulación Coronaria Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Nucl Med Commun Año: 2009 Tipo del documento: Article País de afiliación: Austria

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Volumen Sistólico / Imagen de Acumulación Sanguínea de Compuerta / Tomografía Computarizada de Emisión de Fotón Único / Función Ventricular Izquierda / Circulación Coronaria Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Nucl Med Commun Año: 2009 Tipo del documento: Article País de afiliación: Austria