Your browser doesn't support javascript.
loading
Estimation of radiation exposure of retrospective gated and prospective triggered 128-slice triple-rule-out CT angiography.
Ketelsen, Dominik; Fenchel, Michael; Thomas, Christoph; Buchgeister, Markus; Boehringer, Nadine; Tsiflikas, Ilias; Kaempf, Michael; Claussen, Claus D; Heuschmid, Martin.
Afiliación
  • Ketelsen D; Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany. dominik.ketelsen@med.uni-tuebingen.de
Acta Radiol ; 52(7): 762-6, 2011 Sep 01.
Article en En | MEDLINE | ID: mdl-21498316
ABSTRACT

BACKGROUND:

CT has become an important role in the differential diagnosis of acute chest pain to exclude an aortic dissection, pulmonary embolism and acute coronary artery syndrome. However, the additional radiation exposure is a cause of concern and dose saving strategies should be applied, if possible.

PURPOSE:

To estimate effective dose of retrospective gated and prospective ECG-triggered triple-rule-out computed tomography angiography (TRO-CTA). MATERIAL AND

METHODS:

An Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a 128-slice single source scanner. The following scan parameters were used (retrospective ECG-gated) 120 kV, 190 mAs/rot., collimation 128x0.6 mm, rotation time 0.3 s. Protocols with a simulated heart rate (HR) of 60 and 100 bpm were performed using the standard ECG-pulsing as well as MinDose. Additionally, a prospective triggered TRO-CTA was acquired (HR 60 bpm).

RESULTS:

The estimated effective dose of retrospective ECG-gated TRO-CTA ranged from 7.4-13.4 mSv and from 10.1-17.5 mSv for men and women, respectively. Due to radiosensitive breast tissue, women received a significant increased effective dose of up to 64.7% ± 0.03% (p = 0.028) compared to men. MinDose reduces radiation exposure of up to 33.0% ± 6.5% in comparison to standard ECG-pulsing (p < 0.001). The effective dose increased significantly with lower heart rates (p < 0.001). Prospective ECG-triggered TRO-CTA showed an effective dose of 5.9 mSv and 8.2 mSv for men and women, respectively. Compared to retrospective ECG-gated TRO-CTA a significant dose reduction was observed (p < 0.001).

CONCLUSION:

Due to the significant different dose exposure, scan protocols should be specifically adapted in a patient- and problem-oriented manner.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Tomografía Computarizada por Rayos X / Angiografía Coronaria / Técnicas de Imagen Sincronizada Cardíacas Tipo de estudio: Guideline Límite: Female / Humans / Male Idioma: En Revista: Acta Radiol Año: 2011 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Dosis de Radiación / Tomografía Computarizada por Rayos X / Angiografía Coronaria / Técnicas de Imagen Sincronizada Cardíacas Tipo de estudio: Guideline Límite: Female / Humans / Male Idioma: En Revista: Acta Radiol Año: 2011 Tipo del documento: Article País de afiliación: Alemania